Dell EMC PowerEdge R6525Technical Specifications
Regulatory Model: E67S SeriesRegulatory Type: E67S001July 2020Rev. A02
Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of your product.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid
the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2019 - 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.Other trademarks may be trademarks of their respective owners.
Chapter 1: System overview.......................................................................................................... 5Front view of the system.................................................................................................................................................. 5
Left control panel view.................................................................................................................................................8Right control panel view.............................................................................................................................................. 9
Rear view of the system.................................................................................................................................................. 10
Chapter 2: Technical specifications............................................................................................. 14Chassis dimensions............................................................................................................................................................ 15System weight.................................................................................................................................................................... 16Processor specifications.................................................................................................................................................. 16PSU specifications............................................................................................................................................................. 16Supported operating systems......................................................................................................................................... 17Cooling fan specifications................................................................................................................................................ 17System battery specifications.........................................................................................................................................21Expansion card riser specifications................................................................................................................................21Memory specifications..................................................................................................................................................... 22Storage controller specifications...................................................................................................................................22Drive specifications...........................................................................................................................................................23
Drives..............................................................................................................................................................................23Ports and connectors specifications............................................................................................................................ 23
USB ports specifications........................................................................................................................................... 23NIC port specifications...............................................................................................................................................23Serial connector specifications................................................................................................................................ 24VGA ports specifications........................................................................................................................................... 24IDSDM............................................................................................................................................................................ 24
Video specifications.......................................................................................................................................................... 24Environmental specifications..........................................................................................................................................25
Thermal air restrictions.............................................................................................................................................. 26Thermal restriction matrix......................................................................................................................................... 27
Chapter 3: System diagnostics and indicator codes.....................................................................30Status LED indicators.......................................................................................................................................................30System health and system ID indicator codes............................................................................................................ 31iDRAC Quick Sync 2 indicator codes.............................................................................................................................31iDRAC Direct LED indicator codes................................................................................................................................ 32LCD panel............................................................................................................................................................................ 32
Viewing Home screen................................................................................................................................................. 33Setup menu...................................................................................................................................................................33View menu.....................................................................................................................................................................34
NIC indicator codes...........................................................................................................................................................34Power supply unit indicator codes................................................................................................................................ 35Drive indicator codes........................................................................................................................................................ 37Using system diagnostics................................................................................................................................................ 37
Dell Embedded System Diagnostics........................................................................................................................ 37
Contents
Contents 3
Chapter 4: Safety instructions.................................................................................................... 39
4 Contents
System overviewThe PowerEdge R6525 system is a 1U rack server that supports:
● Two AMD EPYCTM 7002 series processors● 32 DIMM slots● Two redundant AC or DC power supply units● Up to 4 x 3.5-inch, 8 x 2.5-inch, or 10 x 2.5-inch SAS, SATA, or NVMe drives.
NOTE: For more information about how to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe
SSD User's Guide at https://www.dell.com/support Browse all Products > Data Center Infrastructure > Storage
Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Documentation > Manuals and
Documents.
NOTE: All instances of SAS, SATA drives, PCIe SSDs, and NVMe are referred to as drives in this document, unless specified
otherwise.
For more information about supported drives, see the Drive specifications section.Topics:
• Front view of the system• Rear view of the system
Front view of the system
Figure 1. Front view of the 10 x 2.5-inch drive system
Table 1. Features available on the front of the system
Item Ports, panels, andslots
Icon Description
1 Left control panel N/A Contains the system health, system ID, status LED, and theiDRAC Quick Sync 2 (wireless) indicator.
NOTE: The iDRAC Quick Sync 2 indicator is available onlyon certain configurations.
● Status LED: Enables you to identify any failed hardwarecomponents. There are up to five status LEDs and an overallsystem health LED (Chassis health and system ID) bar. Formore information, see the Status LED indicators section.
● Quick Sync 2 (wireless): Indicates a Quick Sync enabledsystem. The Quick Sync feature is optional. This featureallows management of the system by using mobile devicesthat are called as OpenManage Mobile (OMM) feature.Using iDRAC Quick Sync 2 with OpenManage Mobile (OMM)aggregates hardware or firmware inventory and various
1
System overview 5
Table 1. Features available on the front of the system (continued)
Item Ports, panels, andslots
Icon Description
system level diagnostic and error information that can beused in troubleshooting the system. For more information,see the iDRAC User's Guide available at https://www.dell.com/idracmanuals
2 VGA port Enables you to connect a display device to the system. For moreinformation, see the VGA ports specifications on page 24section.
3 Right control panel N/A Contains the power button, USB port, iDRAC Direct micro port,and the iDRAC Direct status LED.
4 Information tag The Information tag is a slide-out label panel that containssystem information such as Service Tag, NIC, MAC address, andso on. If you have opted for the secure default access to iDRAC,the Information tag also contains the iDRAC secure defaultpassword.
5 Drive (10) N/A Enables you to install drives that are supported on your system.For more information about drives, see the Drives section.
Figure 2. Front view of the 8 x 2.5-inch drive system
Table 2. Features available on the front of the system
Item Ports, panels, andslots
Icon Description
1 Left control panel N/A Contains the system health, system ID, status LED, and theiDRAC Quick Sync 2 (wireless) indicator.
NOTE: The iDRAC Quick Sync 2 indicator is available onlyon certain configurations.
● Status LED: Enables you to identify any failed hardwarecomponents. There are up to five status LEDs and an overallsystem health LED (Chassis health and system ID) bar. Formore information, see the Status LED indicators section.
● Quick Sync 2 (wireless): Indicates a Quick Sync enabledsystem. The Quick Sync feature is optional. This featureallows management of the system by using mobile devicesthat are called as OpenManage Mobile (OMM) feature.Using iDRAC Quick Sync 2 with OpenManage Mobile (OMM)aggregates hardware or firmware inventory and varioussystem level diagnostic and error information that can beused in troubleshooting the system. For more information,see the iDRAC User's Guide available at https://www.dell.com/idracmanuals
2 Drive (8) N/A Enables you to install drives that are supported on your system.For more information about drives, see the Drives section.
6 System overview
Table 2. Features available on the front of the system (continued)
Item Ports, panels, andslots
Icon Description
3 Right control panel N/A Contains the power button, USB port, iDRAC Direct micro port,and the iDRAC Direct status LED.
4 VGA port Enables you to connect a display device to the system. For moreinformation, see the VGA ports specifications on page 24section.
5 Information tag The Information tag is a slide-out label panel that containssystem information such as Service Tag, NIC, MAC address, andso on. If you have opted for the secure default access to iDRAC,the Information tag also contains the iDRAC secure defaultpassword.
Figure 3. Front view of the 4 x 3.5-inch drive system
Table 3. Features available on the front of the system
Item Ports, panels, andslots
Icon Description
1 Left control panel N/A Contains the system health, system ID, status LED, and theiDRAC Quick Sync 2 (wireless) indicator.
NOTE: The iDRAC Quick Sync 2 indicator is available onlyon certain configurations.
● Status LED: Enables you to identify any failed hardwarecomponents. There are up to five status LEDs and an overallsystem health LED (Chassis health and system ID) bar. Formore information, see the Status LED indicators section.
● Quick Sync 2 (wireless): Indicates a Quick Sync enabledsystem. The Quick Sync feature is optional. This featureallows management of the system by using mobile devicesthat are called as OpenManage Mobile (OMM) feature.Using iDRAC Quick Sync 2 with OpenManage Mobile (OMM)aggregates hardware or firmware inventory and varioussystem level diagnostic and error information that can beused in troubleshooting the system. For more information,see the iDRAC User's Guide available at https://www.dell.com/idracmanuals
2 Drive (4) N/A Enables you to install drives that are supported on your system.For more information about drives, see the Drives section.
3 VGA port Enables you to connect a display device to the system. For moreinformation, see the VGA ports specifications on page 24section.
4 Right control panel N/A Contains the power button, USB port, iDRAC Direct micro port,and the iDRAC Direct status LED.
System overview 7
Table 3. Features available on the front of the system (continued)
Item Ports, panels, andslots
Icon Description
5 Information tag The Information tag is a slide-out label panel that containssystem information such as Service Tag, NIC, MAC address, andso on. If you have opted for the secure default access to iDRAC,the Information tag also contains the iDRAC secure defaultpassword.
For more information about the ports, see the Technical Specifications section.
Left control panel view
Figure 4. Left control panel without optional iDRAC Quick Sync 2 indicator
Figure 5. Left control panel with optional iDRAC Quick Sync 2 indicator
Table 4. Left control panel
Item Indicator, button, orconnector
Icon Description
1 Status LED indicators N/A Indicates the status of the system. For more information, seethe Status LED indicators section.
2 System health and systemID indicator
Indicates the system health. For more information, see theSystem health and system ID indicator codes section.
3 iDRAC Quick Sync 2wireless indicator(optional)
Indicates if the iDRAC Quick Sync 2 wireless option is activated.The Quick Sync 2 feature allows management of the systemusing mobile devices. This feature aggregates hardware/firmware inventory and various system level diagnostic/errorinformation that can be used in troubleshooting the system.You can access system inventory, Dell Lifecycle Controller logsor system logs, system health status, and also configure iDRAC,BIOS, and networking parameters. You can also launch thevirtual Keyboard, Video, and Mouse (KVM) viewer and virtualKernel-based Virtual Machine (KVM), on a supported mobile
8 System overview
Table 4. Left control panel (continued)
Item Indicator, button, orconnector
Icon Description
device. For more information, see the Integrated Dell RemoteAccess Controller User's Guide at www.dell.com/poweredgemanuals
NOTE: For more information about the indicator codes, see the System diagnostics and indicator codes section.
Right control panel view
Figure 6. Right control panel view
Table 5. Right control panel
Item Indicator or button Icon Description
1 Power button Indicates if the system is powered on or off. Press thepower button to manually power on or off the system.
NOTE: Press the power button to gracefully shutdown an ACPI-compliant operating system.
2 USB 2.0-compliant port The USB port is a 4-pin connector and 2.0-compliant.This port enables you to connect USB devices to thesystem.
3 iDRAC Direct LED indicator N/A The iDRAC Direct LED indicator lights up to indicatethat the iDRAC Direct port is actively connected to adevice.
4 iDRAC Direct port (Micro-ABUSB)
The iDRAC Direct port (Micro-AB USB) enables you toaccess the iDRAC Direct Micro-AB features. For moreinformation, see the iDRAC User's Guide available athttps://www.dell.com/idracmanuals .
NOTE: You can configure iDRAC Direct by using aUSB to micro USB (type AB) cable, which you canconnect to your laptop or tablet. Cable lengthshould not exceed 3 ft (0.91 meters). Quality of thecable might affect performance.
NOTE: For more information about the ports, see the Ports and connectors specifications section.
System overview 9
Rear view of the system
Figure 7. Rear view of the 10 x 2.5-inch drive system
Table 6. Rear view of the system
Item Ports, panels, or slots Icon Description
1 Power supply unit (PSU 1) For more information about the PSU configurations, see theTechnical Specifications section.
2 PCIe expansion card riser(slot 1)
N/A The expansion card riser enables you to connect PCIExpress expansion cards. For more information about theexpansion cards that are supported on your system, seeTechnical Specifications section.
3 PCIe expansion card riser(slot 2)
N/A The expansion card riser enables you to connect PCIExpress expansion cards. For more information about theexpansion cards that are supported on your system, seeTechnical Specifications section.
4 USB 2.0 port (1) This port is USB 2.0-compliant.
5 Power supply unit (PSU2)
For more information about the PSU configurations, see theTechnical Specifications section.
6 VGA port Enables you to connect a display device to the system. Formore information, see the Technical Specifications section.
7 USB 3.0 port (1) This port is USB 3.0-compliant.
8 iDRAC dedicated port Enables you to remotely access iDRAC. For moreinformation, see the iDRAC User’s Guide at www.dell.com/poweredgemanuals.
9 System identificationbutton
Press the system ID button:
● To locate a particular system within a rack.● To turn the system ID on or off.
To reset iDRAC, press and hold the button for more than 16seconds.
NOTE:
● To reset iDRAC using system ID, ensure that thesystem ID button is enabled in the iDRAC setup.
● If the system stops responding during POST, pressand hold the system ID button (for more than 5seconds) to enter the BIOS progress mode.
10 OCP NIC port (optional) N/A This port supports OCP 3.0. The NIC ports are integratedon the OCP card which is connected to the system board.
11 NIC port (2) The NIC ports are embedded on the LOM card that isconnected to the system board.
10 System overview
Table 6. Rear view of the system (continued)
Item Ports, panels, or slots Icon Description
12 BOSS S2 card (optional) N/A This slot supports the BOSS S2 module
For more information about the ports, see the Technical Specifications section.
Figure 8. Rear view of the 8 x 2.5-inch drive system.
Table 7. Rear view of the system
Item Ports, panels, or slots Icon Description
1 Power supply unit (PSU 1) For more information about the PSU configurations, see theTechnical Specifications section.
2 PCIe expansion card riser(slot 1)
N/A The expansion card riser enables you to connect PCIExpress expansion cards. For more information about theexpansion cards that are supported on your system, seeTechnical Specifications section.
3 PCIe expansion card riser(slot 2)
N/A The expansion card riser enables you to connect PCIExpress expansion cards. For more information about theexpansion cards that are supported on your system, seeTechnical Specifications section.
4 USB 2.0 port (1) This port is USB 2.0-compliant.
5 PCIe expansion card riser(slot 3)
N/A The expansion card riser enables you to connect PCIExpress expansion cards. For more information about theexpansion cards that are supported on your system, seeTechnical Specifications section.
6 Power supply unit (PSU2)
For more information about the PSU configurations, see theTechnical Specifications section.
7 VGA port Enables you to connect a display device to the system. Formore information, see the Technical Specifications section.
8 USB 3.0 port (1) This port is USB 3.0-compliant.
9 iDRAC dedicated port Enables you to remotely access iDRAC. For moreinformation, see the iDRAC User’s Guide at www.dell.com/poweredgemanuals.
10 System identificationbutton
Press the system ID button:
● To locate a particular system within a rack.● To turn the system ID on or off.
To reset iDRAC, press and hold the button for more than 16seconds.
NOTE:
● To reset iDRAC using system ID, ensure that thesystem ID button is enabled in the iDRAC setup.
System overview 11
Table 7. Rear view of the system (continued)
Item Ports, panels, or slots Icon Description
● If the system stops responding during POST, pressand hold the system ID button (for more than 5seconds) to enter the BIOS progress mode.
11 OCP NIC port (optional) N/A This port supports OCP 3.0. The NIC ports are integratedon the OCP card which is connected to the system board.
12 NIC port (2) The NIC ports are embedded on the LOM card that isconnected to the system board.
13 BOSS S2 card (optional) N/A This slot supports the BOSS S2 module
For more information about the ports, see the Technical Specifications section.
Figure 9. Rear view of the 4 x 3.5-inch drive system with 2 x 2.5-inch rear drive module
Table 8. Rear view of the system
Item Ports, panels, or slots Icon Description
1 Power supply unit (PSU 1) For more information about the PSU configurations, see theTechnical Specifications section.
2 Rear drive module N/A Enables you to install drives that are supported on yoursystem. For more information about drives, see the Drivessection.
3 USB 2.0 port (1) This port is USB 2.0-compliant.
4 PCIe expansion card riser(slot 3)
N/A The expansion card riser enables you to connect PCIExpress expansion cards. For more information about theexpansion cards that are supported on your system, seeTechnical Specifications section.
5 Power supply unit (PSU2)
For more information about the PSU configurations, see theTechnical Specifications section.
6 VGA port Enables you to connect a display device to the system. Formore information, see the Technical Specifications section.
7 USB 3.0 port (1) This port is USB 3.0-compliant.
8 iDRAC dedicated port Enables you to remotely access iDRAC. For moreinformation, see the iDRAC User’s Guide at www.dell.com/poweredgemanuals.
9 System identificationbutton
Press the system ID button:
● To locate a particular system within a rack.● To turn the system ID on or off.
To reset iDRAC, press and hold the button for more than 16seconds.
NOTE:
12 System overview
Table 8. Rear view of the system (continued)
Item Ports, panels, or slots Icon Description
● To reset iDRAC using system ID, ensure that thesystem ID button is enabled in the iDRAC setup.
● If the system stops responding during POST, pressand hold the system ID button (for more than 5seconds) to enter the BIOS progress mode.
10 OCP NIC port (optional) N/A This port supports OCP 3.0. The NIC ports are integratedon the OCP card which is connected to the system board.
11 NIC port (2) The NIC ports are embedded on the LOM card that isconnected to the system board.
12 BOSS S2 card (optional) N/A This slot supports the BOSS S2 module
For more information about the ports, see the Technical Specifications section.
System overview 13
Technical specifications
The technical and environmental specifications of your system are outlined in this section.Topics:
• Chassis dimensions• System weight• Processor specifications• PSU specifications• Supported operating systems• Cooling fan specifications• System battery specifications• Expansion card riser specifications• Memory specifications• Storage controller specifications• Drive specifications• Ports and connectors specifications• Video specifications• Environmental specifications
2
14 Technical specifications
Chassis dimensions
Figure 10. Chassis dimensions
Table 9. PowerEdge R6525 chassis dimensions
Drives Xa Xb Y Za Zb* Zc
Eight drives 482.0 mm
(18.97 inches)
434.0 mm
(17.08 inches)
42.8 mm
(1.68 inches)
With bezel:35.84 mm (1.4inches)
Without bezel:22.0 mm (0.87inches)
700.7 mm
(21.58 inches)
(Ear to rearwall)
736.27 mm
(28.98 inches)
(Ear to PSUhandle)
Four or tendrives
482.0 mm
(18.97 inches)
434.0 mm
(17.08 inches)
42.8 mm
(1.68 inches)
With bezel:35.84 mm (1.4inches)
Without bezel:22.0 mm (0.87inches)
751.48 mm
(29.58 inches)
(Ear to I/Olabel)
787.05 mm
(30.98 inches)
(Ear to PSUhandle)
NOTE: Zb* is the nominal rear wall external surface where the system board I/O connectors reside.
Technical specifications 15
System weightTable 10. PowerEdge R6525 system weight
System configuration Maximum weight (with all drives/SSDs)
4 x 3.5-inch 21.8 kg (48.06 lb)
8 x 2.5-inch 19.2 kg (42.33 lb)
10 x 2.5-inch 21.8 kg (48.06 lb)
Processor specificationsTable 11. PowerEdge R6525 processor specifications
Supported processor Number of processors supported
AMD EPYC 7002 series processors Two
PSU specificationsThe PowerEdge R6525 system supports up to two AC or DC power supply units (PSUs).
WARNING: Instructions for the qualified electricians only:
System using -(48-60) V DC or 240 V DC power supplies are intended for restricted access locations in
accordance with Articles 110-5, 110-6, 110-11, 110-14, and 110-17 of the National Electrical Code, American
National Standards Institute (ANSI)/National Fire Protection Association (NFPA) 70.
240 V DC power supplies shall be connected to the 240 V DC outlet from certified power distribution units if
applicable in country of use.
Power supply cords/jumper cords and the associated plugs/inlets/connectors shall have appropriate electrical
ratings referencing the rating label on the system when used for connection.
Table 12. PowerEdge R6525 PSU specifications
PSU Class Heat dissipation(maximum)
Frequency Voltage Current
800 W AC mixedmode
Platinum 3139 BTU/hr 50/60 Hz 100 -240 V AC,autoranging
9.2 - 4.7 A
800 W HVDC Platinum 3139 BTU/hr 50/60 Hz 240 V DC 3.8 A
800 W HVDCmixed mode
Platinum 3000 BTU/hr 50/60 Hz 240 V DC 3.8 A
1400 W AC mixedmode
Platinum 5459 BTU/hr 50/60 Hz 100 -240 V AC,autoranging
12 - 8 A
1400 W HVDC Platinum 5459 BTU/hr 50/60 Hz 240 V DC 6.6 A
1400 W HVDCmixed mode
Platinum 5250 BTU/hr 50/60 Hz 240 V DC 6.6 A
NOTE: When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system
power consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA.
16 Technical specifications
Supported operating systemsThe PowerEdge R6525 supports the following operating systems:
● Canonical Ubuntu Server LTS● Microsoft Windows Server with Hyper-V● Red Hat Enterprise Linux● SUSE Linux Enterprise Server● VMware ESXi
For more information, see www.dell.com/ossupport.
Cooling fan specificationsThe PowerEdge R6525 system supports up to four standard (STD), high performance silver grade (HPR (Silver)), or highperformance gold grade (HPR (Gold)) dual cooling fan modules.
Table 13. Cooling fan specifications
Fan type Abbreviation Also knownas
Labelcolor
Label image
Standardfan
STD STD No label
Figure 11. Standard fan
Highperformance (Silvergrade) fan
HPR (Silver) HPR Silver
NOTE: New cooling fans comes with the High PerformanceSilver Grade label. While the older cooling fans has the HighPerformance label.
Technical specifications 17
Table 13. Cooling fan specifications (continued)
Fan type Abbreviation Also knownas
Labelcolor
Label image
Figure 12. High performance fan
18 Technical specifications
Table 13. Cooling fan specifications (continued)
Fan type Abbreviation Also knownas
Labelcolor
Label image
Figure 13. High performance (Silver grade) fan
Highperformance (Goldgrade) fan
HPR (Gold)VHP - VeryHighPerformance
Gold
NOTE: New cooling fans comes with the High PerformanceGold Grade label. While the older cooling fans has the HighPerformance label.
Technical specifications 19
Table 13. Cooling fan specifications (continued)
Fan type Abbreviation Also knownas
Labelcolor
Label image
Figure 14. High performance fan
20 Technical specifications
Table 13. Cooling fan specifications (continued)
Fan type Abbreviation Also knownas
Labelcolor
Label image
Figure 15. High performance (Gold grade) fan
NOTE: You can distinguish between the High-performance (Silver) fan and High-performance (Gold) fan by the color of
the label.
NOTE: Mixing of STD, HPR (Silver), or HPR (Gold) fan is not supported.
NOTE: The STD, HPR (Silver), or HPR (Gold) fan installation depends on the system configuration. For more information
about the supported fan configuration or matrix, see Thermal restriction matrix.
System battery specificationsThe PowerEdge R6525 system supports CR 2032 3.0-V lithium coin cell system battery.
Expansion card riser specificationsThe PowerEdge R6525 system supports up to four PCI express (PCIe) Gen 4 expansion cards.
Technical specifications 21
Table 14. Expansion card slots supported on the system board
PCIe slot Risers Riser width PCIe slot height PCIe slot length Slot width
Slot 1 R2a (Riser 2) x32 PCIe Low profile Half length x16
Slot 1 R1a (Riser 1) x16 PCIe Full height 3/4th length x16
Slot 2 R2a (Riser 2) x32 PCIe Low profile Half length x16
Slot 2 R4c + R4d (Riser 4) x16 PCIe Full height 3/4th length x16
Slot 3 R3a (Riser 3) x16 PCIe Low profile Half length x16
Memory specificationsThe PowerEdge R6525 system supports the following memory specifications for optimized operation.
Table 15. Memory specifications
DIMM type DIMM rank DIMMcapacity
Single processor Dual processor
MinimumRAM Maximum RAM Minimum
RAM Maximum RAM
RDIMM
Single rank 8 GB 8 GB 128 GB 16 GB 256 GB
Dual rank
16 GB 16 GB 256 GB 32 GB 512 GB
32 GB 32 GB 512 GB 64 GB 1 TB
64 GB 64 GB 1 TB 128 GB 2 TB
LRDIMM Octa rank 128 GB 128 GB 2 TB 256 GB 4 TB
Table 16. Memory module sockets
Memory module sockets Speed
32, 288-pin 3200 MT/s, 2933 MT/s, 2666 MT/s
Storage controller specificationsThe PowerEdge R6525 system supports the following controller cards:
Table 17. PowerEdge R6525 system controller cards
Internal controllers External controllers
● PERC H755N● PERC H745● HBA345● HBA355● S150● H345● Boot Optimized Storage Subsystem (BOSS-S1): HWRAID
2 x M.2 SSDs● Boot Optimized Storage Subsystem (BOSS-S2): HWRAID
2 x M.2 SSDs
● 12 Gbps SAS Ext. HBA● PERC H840
NOTE: The front PERC module for the PowerEdge R6525 system connects to the drive backplane. The front PERC module
is connected in two different ways:
● Front mounting front PERC module
● Rear mounting front PERC module
22 Technical specifications
Drive specifications
Drives
The PowerEdge R6525 system supports:
● 4 x 3.5-inch hot-swappable SAS, SATA drives● 8 x 2.5-inch hot-swappable SAS, SATA drives● 10 x 2.5-inch hot-swappable SAS, SATA , or NVMe drives● 10 + 2 x 2.5-inch hot-swappable SAS, SATA , or NVMe drives
Backplane:
● Up to 2 x 2.5-inch SAS, SATA, or NVMe drives● Up to 4 x 3.5-inch SAS, SATA drives● Up to 8 x 2.5-inch SAS, SATA drives● Up to 10 x 2.5-inch SAS, SATA, or NVMe drives
NOTE: For more information about how to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe
SSD User's Guide at https://www.dell.com/support Browse all Products > Data Center Infrastructure > Storage
Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Documentation > Manuals and
Documents.
Ports and connectors specifications
USB ports specifications
Table 18. PowerEdge R6525 system USB specifications
Front Rear Internal
USB port type No. of ports USB port type No. of ports USB port type No. of ports
USB 2.0-compliant port
One USB 3.0-compliant ports
One Internal USB 3.0-compliant port
One
Micro-USB 2.0compliant port
One USB 2.0-compliant ports
One
NOTE: The micro USB 2.0 compliant port can only be used as an iDRAC Direct or a management port.
NOTE: The USB 2.0 specifications provide a 5 V supply on a single wire to power connected USB devices. A unit load is
defined as 100 mA in USB 2.0, and 150 mA in USB 3.0. A device may draw a maximum of 5 unit loads (500 mA) from a port
in USB 2.0; 6 (900 mA) in USB 3.0.
NOTE: The USB 2.0 interface can provide power to low-power peripherals but must adhere to USB specification. An
external power source is required for higher-power peripherals to function, such as external CD/DVD Drives.
NIC port specifications
The PowerEdge R6525 system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports embedded onthe LAN on Motherboard (LOM) and integrated on the optional OCP cards.
Table 19. NIC port specification
Feature Specifications
LOM card 1 GB x 2
Technical specifications 23
Table 19. NIC port specification (continued)
Feature Specifications
OCP card (OCP 3.0) 1 GbE x 4, 10 GbE x 2, 25 GbE x 2, 25 GbE x 4, 50 GbE x 2,100 GbE x 2
Serial connector specifications
The PowerEdge R6525 system supports one optional card type serial connector, which is a 9-pin connector, Data TerminalEquipment (DTE), 16550-compliant.
The optional serial connector card is installed similar to an expansion card filler bracket.
VGA ports specifications
The PowerEdge R6525 system supports one DB-15 VGA port that is located on the front and rear panel of the system.
IDSDM
The PowerEdge R6525 system supports optional Internal Dual SD module (IDSDM).
The IDSDM supports two SD cards and is available in the following configurations:
Table 20. Supported SD card storage capacity
IDSDM card
● 16 GB● 32 GB● 64 GB
NOTE: One IDSDM card slot is dedicated for redundancy.
NOTE: Use Dell EMC branded SD cards that are associated with the IDSDM configured systems.
Video specificationsThe PowerEdge R6525 system supports integrated Matrox G200 graphics controller with 16 MB of video frame buffer.
Table 21. Supported front video resolution options
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32
24 Technical specifications
Table 22. Supported rear video resolution options
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32
Environmental specificationsNOTE: For additional information about environmental certifications, refer to the Product Environmental Datasheet located
with the Manuals & Documents on www.dell.com/support/home.
Table 23. Operational climatic range category A2
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<=2953 ft)
10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at alltimes)
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F)maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900m (2953 Ft)
Table 24. Operational climatic range category A3
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<=2953 ft)
5–40°C (41–104°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at alltimes)
8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F)maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900m (2953 Ft)
Table 25. Operational climatic range category A4
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<=2953 ft)
5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at alltimes)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F)maximum dew point
Technical specifications 25
Table 25. Operational climatic range category A4 (continued)
Temperature Specifications
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900m (2953 Ft)
Table 26. Shared requirements across all categories
Temperature Specifications
Allowable continuous operations
Maximum temperature gradient (applies to bothoperation and non-operation)
20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15minutes), 5°C in an hour* (9°F in an hour) for tape hardware
NOTE: * - Per ASHRAE thermal guidelines for tape hardware, these arenot instantaneous rates of temperature change.
Non-operational temperature limits -40 to 65°C (-40 to 149°F)
Non-operational humidity limits 5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude 12,000 meters (39,370 feet)
Maximum operational altitude 3,048 meters (10,000 feet)
Table 27. Maximum vibration specifications
Maximum vibration Specifications
Operating 0.21 Grms at 5 Hz to 500 Hz (all operation orientations)
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 28. Maximum shock pulse specifications
Maximum shock pulse Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y,and z axis of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y,and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Thermal air restrictions
ASHRAE A3 environment
● CPU TDP equal or greater than 180 W are not supported.● Rear drives are not supported.● 128 GB or greater capacity LRDIMMs are not supported.● Two PSUs are required in redundant mode, however PSU failure is not supported.● Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.● GPU is not supported.● BOSS 1.5 is not supported.● NVMe is not supported.
ASHRAE A4 environment
● CPU TDP equal or greater than 155 W are not supported.● Rear drives are not supported.● 128 GB or greater capacity LRDIMMs are not supported.● Two PSUs are required in redundant mode, however PSU failure is not supported.
26 Technical specifications
● Non-Dell qualified peripheral cards and/or peripheral cards greater than Tier 5 cards are not supported.● GPU is not supported.● BOSS 1.5 is not supported.● OCP 3.0 card cooling tier greater than Tier4 is not supported.● NVMe is not supported.
Thermal restriction matrix
Table 29. Thermal restriction matrix
Configuration 4 x 3.5-inch 8 x 2.5-inch 10 x 2.5-inch SAS 10 x 2.5-inch NVMe
Rear configuration 3 LP/ 2 FH 3 LP/ 2 FH 3 LP/ 2 FH 3 LP/ 2 FH
CPU TDP
120 W STD fan
STD heat sink
STD fan
STD heat sink
HPR (gold) fan
STD heat sink
HPR (gold) fan
STD heat sink
155 W STD fan
STD heat sink
STD fan
STD heat sink
HPR (gold) fan
STD heat sink
HPR (gold) fan
STD heat sink
180 W HPR (silver) fan
L-type heat sink
HPR (silver) fan
L-type heat sink
HPR (gold) fan
L-type heat sink
HPR (gold) fan
L-type heat sink
200 W HPR (silver) fan
L-type heat sink
HPR (silver) fan
L-type heat sink
HPR (gold) fan
L-type heat sink
HPR (gold) fan
L-type heat sink
225 W HPR (silver) fan
L-type heat sink
HPR (silver) fan
L-type heat sink
HPR (gold) fan
L-type heat sink
HPR (gold) fan
L-type heat sink
280 W HPR (silver) fan
L-type heat sink
HPR (silver) fan
L-type heat sink
HPR (gold) fan
L-type heat sink
HPR (gold) fan
L-type heat sink
T4 GPU HPR (silver) fan HPR (silver) fan HPR (gold) fan HPR (gold) fan
NOTE: Three dual fan modules are required for single processor, and four dual fan modules are required for dual processor
system.
NOTE: For T4 GPU and 280 W CPU, maximum supported ambient temperature is 30°C. For other configurations maximum
supported ambient temperature is 35°C.
Table 30. Processor and heat sink matrix
Heat sink Processor TDP
STD HSK < 180 W
L-type HSK Processor 1 >= 180 W
L-type HSK Processor 2 >= 180 W
Table 31. Processor support matrix
Processor TDP (W) cTDP Max(W)
Cores Heat sink(HSK) type
Fan type(x4/x8)
Fan type(x10)
Support A3 Support A4
7H12 280 280 64 L-type HSK HPR (silver)fan
HPR (gold)fan
No No
7F72 240 240 24 L-type HSK HPR(silver)fan
HPR (gold)fan
No No
Technical specifications 27
Table 31. Processor support matrix (continued)
Processor TDP (W) cTDP Max(W)
Cores Heat sink(HSK) type
Fan type(x4/x8)
Fan type(x10)
Support A3 Support A4
7F52 225 240 16 L-type HSK HPR (silver)fan
HPR (gold)fan
No No
7662 225 240 64 L-type HSK HPR (silver)fan
HPR (gold)fan
No No
7742 225 240 64 L-type HSK HPR (silver)fan
HPR (gold)fan
No No
7642 225 240 48 L-type HSK HPR (silver)fan
HPR (gold)fan
No No
7552 200 200 48 L-type HSK HPR (silver)fan
HPR (gold)fan
No No
7702 200 200 64 L-type HSK HPR (silver)fan
HPR (gold)fan
No No
7542 225 240 32 L-type HSK HPR (silver)fan
HPR (gold)fan
No No
7532 200 200 32 L-type HSK HPR (silver)fan
HPR (gold)fan
No No
7F32 180 180 8 L-type HSK HPR (silver)fan
HPR (gold)fan
No No
7502 180 200 32 L-type HSK HPR (silver)fan
HPR (gold)fan
No No
7402 180 200 24 L-type HSK HPR (silver)fan
HPR (gold)fan
No No
7452 155 180 32 STD HSK STD fan HPR (gold)fan
Yes No
7352 155 180 24 STD HSK STD fan HPR (gold)fan
Yes No
7302 155 180 16 STD HSK STD fan HPR (gold)fan
Yes No
7282 120 150 16 STD HSK STD fan HPR (gold)fan
Yes Yes
7272 120 150 12 STD HSK STD fan HPR (gold)fan
Yes Yes
7252 120 150 8 STD HSK STD fan HPR (gold)fan
Yes Yes
7262 155 180 8 STD HSK STD fan HPR (gold)fan
Yes No
NOTE: DIMM blanks are required on empty slots if 280 W CPU is installed.
Table 32. T4 GPU support restriction
2.5-inch x 10 2.5-inch x 8 3.5-inch x 4
RearConfig
3 x LP 2 x FH 3 x LP 2 x FH 3 x LP 2 x FH
Slot 1 Supported Supported Supported Supported Supported Supported
Slot 2 Supported Supported Supported Supported Supported Supported
28 Technical specifications
Table 32. T4 GPU support restriction (continued)
2.5-inch x 10 2.5-inch x 8 3.5-inch x 4
RearConfig
3 x LP 2 x FH 3 x LP 2 x FH 3 x LP 2 x FH
Slot 3 Supported NA Not supported NA Not supported NA
NOTE: For T4 GPU or 280 W CPU, maximum supported ambient temperature is 30°C.
Table 33. Label reference
Label Description
STD Standard
HPR (silver) High performance (silver grade)
HPR (gold) High performance (gold grade)
HSK Heat sink
LP Low profile
FH Full height
Technical specifications 29
System diagnostics and indicator codesThe diagnostic indicators on the system front panel display system status during system startup.
Topics:
• Status LED indicators• System health and system ID indicator codes• iDRAC Quick Sync 2 indicator codes• iDRAC Direct LED indicator codes• LCD panel• NIC indicator codes• Power supply unit indicator codes• Drive indicator codes• Using system diagnostics
Status LED indicators
NOTE: The indicators display solid amber if any error occurs.
Figure 16. Status LED indicators
Table 34. Status LED indicators and descriptions
Icon Description Condition Corrective action
Drive indicator The indicator turns solid amber ifthere is a drive error.
● Check the System Event Log to determine if thedrive has an error.
● Run the appropriate Online Diagnostics test.Restart the system and run embeddeddiagnostics (ePSA).
● If the drives are configured in a RAID array,restart the system, and enter the host adapterconfiguration utility program.
Temperatureindicator
The indicator turns solid amber ifthe system experiences a thermalerror (for example, the ambienttemperature is out of range orthere is a fan failure).
Ensure that none of the following conditions exist:
● A cooling fan has been removed or has failed.● System cover, air shroud, or back filler bracket is
removed.● Ambient temperature is too high.● External airflow is obstructed.
If the problem persists, see the Getting help section.
3
30 System diagnostics and indicator codes
Table 34. Status LED indicators and descriptions (continued)
Icon Description Condition Corrective action
Electricalindicator
The indicator turns solid amber ifthe system experiences anelectrical error (for example,voltage out of range, or a failedpower supply unit (PSU) or voltageregulator).
Check the System Event Log or system messagesfor the specific issue. If it is due to a problem withthe PSU, check the LED on the PSU. Reseat thePSU.
If the problem persists, see the Getting help section.
Memory indicator The indicator turns solid amber if amemory error occurs.
Check the System Event Log or system messagesfor the location of the failed memory. Reseat thememory module.
If the problem persists, see the Getting help section.
PCIe indicator The indicator turns solid amber if aPCIe card experiences an error.
Restart the system. Update any required drivers forthe PCIe card. Reinstall the card.
If the problem persists, see the Getting help section.
NOTE: For more information about thesupported PCIe cards, see the Expansion cardinstallation guidelines section.
System health and system ID indicator codesThe system health and system ID indicator is located on the left control panel of the system.
Figure 17. System health and system ID indicator
Table 35. System health and system ID indicator codes
System health and system IDindicator code
Condition
Solid blue Indicates that the system is powered on, is healthy, and system ID mode is not active.Press the system health and system ID button to switch to system ID mode.
Blinking blue Indicates that the system ID mode is active. Press the system health and system IDbutton to switch to system health mode.
Solid amber Indicates that the system is in fail-safe mode. If the problem persists, see the Gettinghelp section.
Blinking amber Indicates that the system is experiencing a fault. Check the System Event Log forspecific error messages. For information about the event and error messagesgenerated by the system firmware and agents that monitor system components, go toqrl.dell.com > Look Up > Error Code, type the error code, and then click Look it up.
iDRAC Quick Sync 2 indicator codesiDRAC Quick Sync 2 module (optional) is located on the left control panel of the system.
System diagnostics and indicator codes 31
Table 36. iDRAC Quick Sync 2 indicators and descriptions
iDRAC Quick Sync 2 indicatorcode
Condition Corrective action
Off (default state) Indicates that the iDRAC Quick Sync 2feature is powered off. Press the iDRACQuick Sync 2 button to power on theiDRAC Quick Sync 2 feature.
If the LED fails to power on, reseat the leftcontrol panel flex cable and check. If the problempersists, see the Getting help section.
Solid white Indicates that iDRAC Quick Sync 2 isready to communicate. Press the iDRACQuick Sync 2 button to power off.
If the LED fails to power off, restart the system.If the problem persists, see the Getting helpsection.
Blinks white rapidly Indicates data transfer activity. If the indicator continues to blink indefinitely, seethe Getting help section.
Blinks white slowly Indicates that firmware update is inprogress.
If the indicator continues to blink indefinitely, seethe Getting help section.
Blinks white five times rapidlyand then powers off
Indicates that the iDRAC Quick Sync 2feature is disabled.
Check if iDRAC Quick Sync 2 feature isconfigured to be disabled by iDRAC. If theproblem persists, see the Getting help section.www.dell.com/poweredgemanuals or DellOpenManage Server Administrator User’s Guideat https://www.dell.com/openmanagemanuals.
Solid amber Indicates that the system is in fail-safemode.
Restart the system. If the problem persists, seethe Getting help section.
Blinking amber Indicates that the iDRAC Quick Sync 2hardware is not responding properly.
Restart the system. If the problem persists, seethe Getting help section.
iDRAC Direct LED indicator codesThe iDRAC Direct LED indicator lights up to indicate that the port is connected and is being used as a part of the iDRACsubsystem.
You can configure iDRAC Direct by using a USB to micro USB (type AB) cable, which you can connect to your laptop or tablet.Cable length should not exceed 3 feet (0.91 meters). Performance could be affected by cable quality. The following tabledescribes iDRAC Direct activity when the iDRAC Direct port is active:
Table 37. iDRAC Direct LED indicator codes
iDRAC Direct LEDindicator code
Condition
Solid green for twoseconds
Indicates that the laptop or tablet is connected.
Blinking green (on fortwo seconds and off fortwo seconds)
Indicates that the laptop or tablet connected is recognized.
Powers off Indicates that the laptop or tablet is unplugged.
LCD panelThe LCD panel provides system information, status, and error messages to indicate if the system is functioning correctly orrequires attention. The LCD panel is used to configure or view the iDRAC IP address of the system. For information about theevent and error messages generated by the system firmware and agents that monitor system components, go to qrl.dell.com >Look Up > Error Code, type the error code, and then click Look it up..
The LCD panel is available only on the optional front bezel. The optional front bezel is hot pluggable.
The status and conditions of the LCD panel are outlined here:
32 System diagnostics and indicator codes
● The LCD backlight is white during normal operating conditions.● If there is an issue, the LCD backlight turns amber and displays an error code followed by descriptive text.
NOTE: If the system is connected to a power source and an error is detected, the LCD turns amber regardless of
whether the system is powered on or off.
● When the system powers off and there are no errors, the LCD enters the standby mode after five minutes of inactivity.Press any button on the LCD to power it on.
● If the LCD panel stops responding, remove the bezel and reinstall it.
If the problem persists, see Getting help.
● The LCD backlight remains off if LCD messaging is powered off using the iDRAC utility, the LCD panel, or other tools.
Figure 18. LCD panel features
Table 38. LCD panel features
Item Button ordisplay
Description
1 Left Moves the cursor back in one-step increments.
2 Select Selects the menu item highlighted by the cursor.
3 Right Moves the cursor forward in one-step increments.
During message scrolling:
● Press and hold the right button to increase scrolling speed.● Release the button to stop.
NOTE: The display stops scrolling when the button is released. After 45 seconds of inactivity,the display starts scrolling.
4 LCD display Displays the system information, status, and error messages or iDRAC IP address.
Viewing Home screen
The Home screen displays user-configurable information about the system. This screen is displayed during normal systemoperation when there are no status messages or errors. When the system turns off and there are no errors, LCD enters thestandby mode after five minutes of inactivity. Press any button on the LCD to turn it on.
1. To view the Home screen, press one of the three navigation buttons (Select, Left, or Right).
2. To navigate to the Home screen from another menu, complete the following steps:
a. Press and hold the navigation button till the up arrow is displayed.
b. Navigate to the Home icon using the up arrow .c. Select the Home icon.d. On the Home screen, press the Select button to enter the main menu.
Setup menu
NOTE: When you select an option in the Setup menu, you must confirm the option before proceeding to the next action.
System diagnostics and indicator codes 33
Table 39. Setup menu
Option Description
iDRAC Select DHCP or Static IP to configure the network mode. If Static IP is selected, the available fields areIP, Subnet (Sub), and Gateway (Gtw). Select Setup DNS to enable DNS and to view domainaddresses. Two separate DNS entries are available.
Set error Select SEL to view LCD error messages in a format that matches the IPMI description in the SEL. Thisenables you to match an LCD message with an SEL entry.
Select Simple to view LCD error messages in a simplified user-friendly description. For information aboutthe event and error messages generated by the system firmware and agents that monitor systemcomponents, go to qrl.dell.com > Look Up > Error Code, type the error code, and then click Look it up..
Set home Select the default information to be displayed on the Home screen. See View menu section for the optionsand option items that can be set as the default on the Home screen.
View menu
NOTE: When you select an option in the View menu, you must confirm the option before proceeding to the next action.
Table 40. View menu
Option Description
iDRAC IP Displays the IPv4 or IPv6 addresses for iDRAC9. Addresses include DNS (Primary andSecondary), Gateway, IP, and Subnet (IPv6 does not have Subnet).
MAC Displays the MAC addresses for iDRAC, iSCSI, or Network devices.
Name Displays the name of the Host, Model, or User String for the system.
Number Displays the Asset tag or the Service tag for the system.
Power Displays the power output of the system in BTU/hr or Watts. The display format can beconfigured in the Set home submenu of the Setup menu.
Temperature Displays the temperature of the system in Celsius or Fahrenheit. The display format canbe configured in the Set home submenu of the Setup menu.
NIC indicator codesEach NIC on the back of the system has indicators that provide information about the activity and link status. The activity LEDindicator indicates if data is flowing through the NIC, and the link LED indicator indicates the speed of the connected network.
Figure 19. NIC indicator codes
1. Link LED indicator2. Activity LED indicator
Table 41. NIC indicator codes
NIC indicator codes Condition
Link and activity indicators are off. Indicates that the NIC is not connected to the network.
34 System diagnostics and indicator codes
Table 41. NIC indicator codes (continued)
NIC indicator codes Condition
Link indicator is green, and activity indicator is blinkinggreen.
Indicates that the NIC is connected to a valid network at its maximumport speed, and data is being sent or received.
Link indicator is amber, and activity indicator is blinkinggreen.
Indicates that the NIC is connected to a valid network at less than itsmaximum port speed, and data is being sent or received.
Link indicator is green, and activity indicator is off. Indicates that the NIC is connected to a valid network at its maximumport speed, and data is not being sent or received.
Link indicator is amber, and activity indicator is off. Indicates that the NIC is connected to a valid network at less than itsmaximum port speed, and data is mot being sent or received.
Link indicator is blinking green, and activity is off. Indicates that the NIC identify is enabled through the NICconfiguration utility.
Power supply unit indicator codesAC power supply units (PSUs) have an illuminated translucent handle that serves as an indicator. The indicator shows if power ispresent or if a power fault has occurred.
Figure 20. AC PSU status indicator
1. AC PSU handle2. Socket3. Release latch
Table 42. AC PSU status indicator codes
Power indicator codes Condition
Green Indicates that a valid power source is connected to the PSU and the PSU is operational.
Blinking amber Indicates an issue with the PSU.
Not powered on Indicates that the power is not connected to the PSU.
Blinking green Indicates that the firmware of the PSU is being updated.CAUTION: Do not disconnect the power cord or unplug the PSU when updatingfirmware. If firmware update is interrupted, the PSUs do not function.
Blinking green andpowers off
When hot-plugging a PSU, it blinks green five times at a rate of 4 Hz and powers off. This indicatesa PSU mismatch due to efficiency, feature set, health status, or supported voltage.
CAUTION: If two PSUs are installed, both the PSUs must have the same type of label;for example, Extended Power Performance (EPP) label. Mixing PSUs from previousgenerations of PowerEdge servers is not supported, even if the PSUs have the samepower rating. This results in a PSU mismatch condition or failure to power on thesystem.
System diagnostics and indicator codes 35
Table 42. AC PSU status indicator codes (continued)
Power indicator codes Condition
CAUTION: If two PSUs are used, they must be of the same type and have the samemaximum output power.
CAUTION: When correcting a PSU mismatch, replace the PSU with the blinkingindicator. Swapping the PSU to make a matched pair can result in an error conditionand an unexpected system shutdown. To change from a high output configuration to alow output configuration or vice versa, you must power off the system.
CAUTION: AC PSUs support both 240 V and 120 V input voltages with the exception ofTitanium PSUs, which support only 240 V. When two identical PSUs receive differentinput voltages, they can output different wattages, and trigger a mismatch.
Table 43. DC PSU status indicator codes
Power indicator codes Condition
Green Indicates that a valid power source is connected to the PSU,and the PSU is operational.
Blinking amber Indicates an issue with the PSU.
Not powered on Indicates that the power is not connected to the PSU.
Blinking green When hot-plugging a PSU, it blinks green five times at a rateof 4 Hz and powers off. This indicates a PSU mismatch due toefficiency, feature set, health status, or supported voltage.
CAUTION: If two PSUs are installed, both the PSUsmust have the same type of label; for example,Extended Power Performance (EPP) label. MixingPSUs from previous generations of PowerEdgeservers is not supported, even if the PSUs have thesame power rating. This results in a PSU mismatchcondition, or failure to power on the system.
CAUTION: If two PSUs are used, they must be of thesame type and have the same maximum outputpower.
CAUTION: When correcting a PSU mismatch, replacethe PSU with the blinking indicator. Swapping thePSU to make a matched pair can result in an errorcondition and an unexpected system shutdown. Tochange from a High Output configuration to a LowOutput configuration or conversely, you must poweroff the system.
CAUTION: Combining AC and DC PSUs is notsupported.
36 System diagnostics and indicator codes
Drive indicator codesThe LEDs on the drive carrier indicates the state of each drive. Each drive carrier has two LEDs: an activity LED (green) and astatus LED (bicolor, green/amber). The activity LED blinks whenever the drive is accessed.
Figure 21. Drive indicators
1. Drive activity LED indicator2. Drive status LED indicator3. Drive capacity label
NOTE: If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not power on.
NOTE: Drive status indicator behavior is managed by Storage Spaces Direct. Not all drive status indicators may be used.
Table 44. Drive indicator codes
Drive status indicator code Condition
Blinks green twice per second Indicates that the drive is being identified or preparing for removal.
Off Indicates that the drive is ready for removal.NOTE: The drive status indicator remains off until all drivesare initialized after the system is powered on. Drives are notready for removal during this time.
Blinks green, amber, and then powers off Indicates that there is an expected drive failure.
Blinks amber four times per second Indicates that the drive has failed.
Blinks green slowly Indicates that the drive is rebuilding.
Solid green Indicates that the drive is online.
Blinks green for three seconds, amber for three seconds,and then powers off after six seconds
Indicates that the rebuild has stopped.
Using system diagnosticsIf you experience an issue with the system, run the system diagnostics before contacting Dell for technical assistance. Thepurpose of running system diagnostics is to test the system hardware without using additional equipment or risking data loss. Ifyou are unable to fix the issue yourself, service and support personnel can use the diagnostics results to help you solve theissue.
Dell Embedded System Diagnostics
NOTE: The Dell Embedded System Diagnostics is also known as Enhanced Pre-boot System Assessment (ePSA)
diagnostics.
The Embedded System Diagnostics provide a set of options for particular device groups or devices allowing you to:
● Run tests automatically or in an interactive mode● Repeat tests
System diagnostics and indicator codes 37
● Display or save test results● Run thorough tests to introduce additional test options to provide extra information about the failed device(s)● View status messages that inform you if tests are completed successfully● View error messages that inform you of issues encountered during testing
Running the Embedded System Diagnostics from the Dell LifecycleController
1. As the system boots, press F10.
2. Select Hardware Diagnostics → Run Hardware Diagnostics.The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnosticsstarts executing the tests on all the detected devices.
Running the Embedded System Diagnostics from Boot Manager
Run the Embedded System Diagnostics (ePSA) if your system does not boot.
1. When the system is booting, press F11.
2. Use the up arrow and down arrow keys to select System Utilities > Launch Diagnostics.
3. Alternatively, when the system is booting, press F10, select Hardware Diagnostics > Run Hardware Diagnostics.The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnosticsstarts executing the tests on all the detected devices.
System diagnostic controls
Table 45. System diagnostic controls
Menu Description
Configuration Displays the configuration and status information of alldetected devices.
Results Displays the results of all tests that are run.
System health Provides the current overview of the system performance.
Event log Displays a time-stamped log of the results of all tests run onthe system. This is displayed if at least one event descriptionis recorded.
38 System diagnostics and indicator codes
Safety instructionsNOTE: Whenever you need to lift the system, get others to assist you. To avoid injury, do not attempt to lift the system by
yourself.
WARNING: Opening or removing the system cover while the system is powered on may expose you to a risk of
electric shock.
CAUTION: Do not operate the system without the cover for a duration exceeding five minutes.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by
your warranty. Read and follow the safety instructions that are shipped with your product.
NOTE: It is recommended that you always use an antistatic mat and antistatic strap while working on components inside
the system.
NOTE: To ensure proper operation and cooling, all bays in the system and system fans must be populated always with
either a component or with a blank.
4