4
SERVER CONNECTIVITY DATA SHEET www.brocade.com BROCADE 415, 425, 815, AND 825 FIBRE CHANNEL HBAs HIGHLIGHTS Centralizes management across the data center by leveraging Brocade Network Advisor Provides fabric-based boot LUN discovery for simplified SAN boot configuration for both DAS and diskless server deployments • Maximizes bus throughput with a Fibre Channel to PCIe Gen2 (x8) bus interface with intelligent lane negotiation • Delivers unprecedented performance with up to 500,000 IOPS per port, 1 million IOPS per dual-port adapter, and up to 1600 MB/sec per port full duplex • Supports NPIV with up to 255 virtual ports • Provides optimal support for Windows Server 2012, including the new virtual Fibre Channel feature Accelerates deployment and troubleshooting time with Dynamic Fabric Provisioning (DFP), critical monitoring, and advanced diagnostic features Server Connectivity for Next-Generation Data Centers Today’s IT professionals face the difficult challenge of reducing data center cost and complexity while satisfying numerous Service Level Agreements (SLAs) and performance requirements. As a result, organizations are seeking ways to improve server and storage utilization, reduce ongoing operational costs, and increase their flexibility and responsiveness. Two major industry trends aimed at reducing cost and complexity—server consolidation and virtualization—have quickly become the highest priorities for server administrators. Most data centers were designed to meet basic connectivity needs for physical servers, switches, and storage. However, consolidation and virtualization drive new connectivity requirements that legacy solutions are no longer able to meet, such as streamlined manageability, increased performance, and virtualization awareness. Performance of the applications under load and manageability are often critical concerns for organizations deploying server virtualization. Brocade ® 415 and 425 4 Gbps Fibre Channel Host Bus Adapters (HBAs) and Brocade 815 and 825 8 Gbps Fibre Channel HBAs are a new class of server connectivity products with unmatched hardware capabilities and unique software features. This new class of HBAs is designed to help IT organizations deploy and manage end-to-end Storage Area Network (SAN) services across next-generation data centers. While legacy HBA providers focus on simple connectivity, the Brocade 4 Gbps and 8 Gbps HBAs leverage five generations of Application-Specific Integrated Circuit (ASIC) design. The current ASIC is an evolution of the industry-leading Brocade Fibre Channel switching ASIC. It leverages the same technology and features that make Brocade the market leader in storage networking, including frame-based trunking for additional performance and availability, and Virtual Channels (VCs) for Quality of Service (QoS) and isolation. This enables organizations to extend essential Virtual Machine (VM)-aware Brocade Advanced Fabric Services into the server. UNIFIED MANAGEMENT Brocade Network Advisor can monitor and manage multiple HBAs across a data center simultaneously—along with Brocade switches and backbones—all from a single central location. This enables organizations to The Brocade One ® strategy helps simplify networking infrastructures through innovative technologies and solutions. Brocade 415, 425, 815, and 825 Host Bus Adapters (HBAs) support this strategy by simplifying and optimizing server connectivity to Fibre Channel fabrics in highly virtualized data centers.

DATA SHEET BROCADE 415, 425, 815, AND 825 ...€¦ · ERER CONNECTIITY DATA SHEET BROCADE 415, 425, 815, AND 825 FIBRE CHANNEL HBAs HIGHLIGHTS • Centralizes management across the

  • Upload
    others

  • View
    14

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DATA SHEET BROCADE 415, 425, 815, AND 825 ...€¦ · ERER CONNECTIITY DATA SHEET BROCADE 415, 425, 815, AND 825 FIBRE CHANNEL HBAs HIGHLIGHTS • Centralizes management across the

SERVER CONNECTIVITY

DATA SHEET www.brocade.com

BROCADE415, 425, 815, AND 825FIBRE CHANNEL HBAs

HIGHLIGHTS•Centralizes management across

the data center by leveraging Brocade Network Advisor

•Provides fabric-based boot LUN discoveryforsimplifiedSANbootconfigurationforbothDASand diskless server deployments

•MaximizesbusthroughputwithaFibreChanneltoPCIeGen2(x8)businterfacewith intelligent lane negotiation

•Deliversunprecedentedperformancewithupto500,000IOPSperport, 1millionIOPSperdual-portadapter,andupto1600MB/secperportfullduplex

•SupportsNPIVwithupto255 virtualports

•ProvidesoptimalsupportforWindowsServer2012,includingthe newvirtualFibreChannelfeature

•Accelerates deployment and troubleshootingtimewith Dynamic Fabric Provisioning (DFP), critical monitoring, and advanced diagnosticfeatures

Server Connectivity for Next-Generation Data Centers

Today’sITprofessionalsfacethedifficultchallengeofreducingdatacentercostandcomplexitywhilesatisfyingnumerousServiceLevelAgreements(SLAs)andperformancerequirements.Asaresult,organizations are seeking ways to improve serverandstorageutilization,reduceongoing operational costs, and increase theirflexibilityandresponsiveness.

Twomajorindustrytrendsaimedatreducingcost and complexity—server consolidation andvirtualization—havequicklybecomethehighestprioritiesforserveradministrators.Most data centers were designed to meet basic connectivity needs for physical servers, switches,andstorage.However,consolidationandvirtualizationdrivenewconnectivityrequirementsthatlegacysolutionsarenolongerabletomeet,suchasstreamlinedmanageability, increased performance, and virtualizationawareness.Performanceoftheapplicationsunderloadandmanageabilityare often critical concerns for organizations deployingservervirtualization.

Brocade® 415 and 425 4 Gbps Fibre ChannelHostBusAdapters(HBAs)andBrocade 815 and 825 8 Gbps Fibre Channel HBAs are a new class of server connectivityproductswithunmatchedhardwarecapabilitiesanduniquesoftwarefeatures.ThisnewclassofHBAsisdesignedto help IT organizations deploy and manage end-to-endStorageAreaNetwork(SAN)servicesacrossnext-generationdatacenters.

WhilelegacyHBAprovidersfocuson simple connectivity, the Brocade 4 Gbps and8GbpsHBAsleveragefivegenerationsofApplication-SpecificIntegratedCircuit(ASIC)design.ThecurrentASICisanevolutionoftheindustry-leadingBrocadeFibreChannelswitchingASIC.Itleveragesthesametechnologyandfeaturesthatmake Brocade the market leader in storage networking,includingframe-basedtrunkingfor additional performance and availability, andVirtualChannels(VCs)forQualityofService(QoS)andisolation.ThisenablesorganizationstoextendessentialVirtualMachine(VM)-awareBrocadeAdvancedFabricServicesintotheserver.

UNIFIED MANAGEMENTBrocade Network Advisor can monitor and managemultipleHBAsacrossadatacentersimultaneously—alongwithBrocadeswitchesand backbones—all from a single central location.Thisenablesorganizationsto

The Brocade One® strategy helps simplifynetworkinginfrastructuresthroughinnovativetechnologiesandsolutions.Brocade415,425,815, and825HostBusAdapters(HBAs)supportthisstrategybysimplifying and optimizing server connectivity to Fibre Channel fabrics in highly virtualizeddatacenters.

Page 2: DATA SHEET BROCADE 415, 425, 815, AND 825 ...€¦ · ERER CONNECTIITY DATA SHEET BROCADE 415, 425, 815, AND 825 FIBRE CHANNEL HBAs HIGHLIGHTS • Centralizes management across the

monitorperformanceacrossgroupsofHBAsandHBAportsatthesametime,capturediagnosticsinformationautomaticallyintheeventofafailure,andreceiveproactivealertswhenHBAeventsoccur(seeFigure1).

BrocadeHBAsalsoenableVMdiscoveryinVMwareESXenvironmentswithinBrocadeNetworkAdvisor.VMdiscoveryprovidesanend-to-endviewoftheVM-to-LogicalUnitNumber(LUN)pathinformationforalltheVMsrunningoneachphysicalserver,withdetailedinformationsuchashostOS,assignedCPUandmemoryresources,andall the data stores associated with each VM.ThisprovidesunprecedentedlevelsofvisibilityintothevirtualserverinfrastructureforSANadministrators,enablingthemtomoreefficientlymanagetheirstoragenetworkresources.CoupledwithN_PortIDVirtualization(NPIV),BrocadeNetworkAdvisor can also provide end-to-end performancestatisticswithVMgranularity.

Boot-over-SANenablesthedeploymentofbothDirect-AttachedStorage(DAS)point-to-point topology as well as diskless servers andcentralizedmanagementofOSimagesinthesharedstoragepool.Traditionalboot-over-SANenvironments,however,requireaccesstoeachindividualHBABIOS(andeachindividualserverconsole),makingthemcumbersometoconfigure,laborioustomaintain,andpronetohumanerror.To simplify the management of boot-over-SANenvironments,BrocadeHBAsprovidefabric-basedbootLUNdiscovery—afeaturethatenableseachservertoautomaticallyretrieve its boot LUN information from the switchfabric.Thisprovidesacentralizedmanagementpointforallboot-over-SANoperationsthroughBrocadeNetworkAdvisor,enablingorganizationstofullyreapthebenefitsofdisklessservers.

AllHBAmanagementandVMvisibilityfeaturesareavailableacrossallthreeeditions of Brocade Network Advisor: Professional,ProfessionalPlus,andEnterprise.Forsimpledeviceconfiguration,driverupdates,ortoobtainHBAandportstatistics, a Graphical User Interface (GUI) element manager and a Command Line Interface(CLI)arealsoavailable.BothBrocade Network Advisor and the element manager provide open APIs and standards-basedinterfacesforintegrationwithpopularthird-party applications and higher-level frameworks to help orchestrate Brocade hardwareandSANservices.

Brocade Network Advisor

HBAs

VM Visibility

Fabric

End-

to-E

nd V

isib

ility

Storage

E-mail Database

IOP

S

1.7

x

BrocadeBrand ABrand B

31

5,0

00

17

6,0

00

1.8

x

2.7

x

3.9

x

HighMediumLow

VM3VM2VM1

Hypervisor

OS OS OS

Figure 3.SAOextendsQoStotheVMlevel.

Figure 2. Brocade HBAs can provide nearly three times the performance of competing offeringsinreal-worldapplicationscenarios.

Figure 1.BrocadeNetworkAdvisorprovidesunifiedmanagementofSANandHBAresourceswithend-to-endVMvisibility.

UNMATCHED PERFORMANCEWiththerecentadvancesinservertechnology,includingIntelNehalemprocessors,serversarenowcapableofrunningmoreworkloadsthanever.Thisdriveshigherconsolidationandvirtualizationratios,withmoreVMsbeingdeployedperserver,whichinturndrivesunprecedentedI/Orequirements.ThesuperiorperformanceofBrocadeHBAsprovidesthenecessarybandwidthandI/Opower for the most demanding environments (seeFigure2).

Ultimately,thismeansthatbusinessesofallsizescanscaletheirvirtualserverdeploymentsandvirtualizehighlydemanding applications with greater

confidence,resultinginbetterserverresourceutilizationandlowercapital andoperationalcosts.

OPTIMIZED FOR VIRTUAL ENVIRONMENTSInanon-virtualizedenvironment,everyapplication is tied to a physical server, which inturnconnectstoaphysicalSANswitchportina“static”manner.ApplyingnetworkpoliciessuchaszoningorQoS—ormonitoringapplicationperformance—issimplebecausethe application is permanently associated withthephysicalport.

Withservervirtualization,multipleapplications reside in a physical server and

Page 3: DATA SHEET BROCADE 415, 425, 815, AND 825 ...€¦ · ERER CONNECTIITY DATA SHEET BROCADE 415, 425, 815, AND 825 FIBRE CHANNEL HBAs HIGHLIGHTS • Centralizes management across the

shareaphysicalSANport.Furthermore,applicationscanmoveacrossthevirtualizedserverinfrastructure,basedonanumberofuser-definedpolicies,torespondtodynamicbusinessrequirements.Avirtualization-awareSANinfrastructureandserverconnectivitysolutionenablesorganizations to apply network policies at theVMlevel.Suchpolicieswillthenbeableto “follow” the application transparently asitmovestoanewphysicalserver.

BrocadeHBAswerebuiltfromthegroundupwithvirtualizationinmind.TheysupportNPIVwithupto255virtualports,andtheyarequalifiedwithallmajorhypervisorsolutionsintheindustry.LeveragingNPIVtechnology, organizations can not only extend Brocade fabric services to the server, butallthewaytotheVMandapplicationlevel.ServerApplicationOptimization(SAO)helps IT organizations avoid downtime and moreeffectivelymeettheirSLAsbyallowingthemtoapplyQoSpolicieswithaper-VMgranularityandensurethatmission-criticalVMswillnotbeaffectedintheeventofHBAlink congestion—even as they move across theinfrastructure(seeFigure3).SAOalsoprovidesisolationtoprotectindividualVMsfrom the effect of slow-drain devices that wouldotherwiseimpacttheentirephysicalserverandallapplications.

Optimal Support for Windows Server 2012 BysupportingWindowsServer2012,Brocade Fibre Channel HBAs enhance their abilitytosupportWindows-basedvirtualworkloads.Furthermore,theirsupportoftheHyper-VvirtualFibreChannelfeatureenables direct connectivity to Fibre Channel SANsfromwithinaHyper-VVM,allowingFibreChannelSANstoseamlesslysupportWindows-basedvirtualizedworkloads.SupportforFibreChannelinHyper-Vguestsalsoincludessupportformanyhigh-availabilityfeatures,suchasvirtualSANs,clusteredVMs,livemigration,andMulti-PathI/O(MPIO).

SIMPLIFYING SERVER DEPLOYMENT WITH DYNAMIC FABRIC PROVISIONING AND ENHANCED DIAGNOSTICS Dynamic Fabric Provisioning (DFP) allows organizations to eliminate fabric reconfigurationwhenaddingorreplacingserversthroughthevirtualizationofhostWorldWideNames(WWNs).ItcombinesBrocade switch and adapter technology toreduceoreliminatetheneedtomodifyzoningorLogicalUnitNumber(LUN)masking.Inaddition,DFPenablespre-provisioningofvirtualWWNs,helpingorganizationseliminatetime-consuming

stepswhendeployingnewequipmentormovingdeviceswithinaswitch.

DiagnosticPorts(D_Ports)areanewport mode that enables administrators to quicklyidentifyandisolateopticsandcableproblems,reducingfabricdeploymentanddiagnostictimes.OrganizationsalsocanuseD_PortstorunavarietyofteststhroughBrocade Network Advisor or Command LineInterface(CLI)totestports,SFPs,andcablesforfaults,latency,anddistance.

BROCADE GLOBAL SERVICES BrocadeGlobalServiceshastheexpertisetohelporganizationsbuildscalable,efficientcloudinfrastructures.Leveraging15 years of expertise in storage, networking, andvirtualization,BrocadeGlobalServicesdelivers world-class professional services, technicalsupport,networkmonitoringservices,andeducation,enablingorganizations to maximize their Brocade investments, accelerate new technology deployments, and optimize the performance ofnetworkinginfrastructures.

MAXIMIZING INVESTMENTSTo help optimize technology investments, Brocade and its partners offer complete solutionsthatincludeprofessionalservices,technicalsupport,andeducation.Formoreinformation, contact a Brocade sales partner or visit www.brocade.com.

BROCADE 415, 425, 815, AND 825 SPECIFICATIONS

ModelsBrocade 415 Single-port,4GbpsHBA

Brocade 425 Dual-port,4GbpsHBA

Brocade 815 Single-port,8GbpsHBA

Brocade 825 Dual-port,8GbpsHBA

Fibre Channel SpecificationsData rate Brocade415/425:4Gbps(800MB/sec);

2Gbps(400MB/sec);1Gbps(200MB/sec)(perport) Brocade815/825:8Gbps(1600MB/sec); 4Gbps(800MB/sec);2Gbps(400MB/sec)(perport)

Performance Upto500,000IOPSperportat4Gbpsand 8 Gbps

• 315,000IOPSperportat8Gbpswith 4KBblocksizeand50%read/50%writeoperations (typical e-mail)

• 176,000IOPSperportat8Gbpswith 8KBblocksizeand50%read/50%writeoperations (typical database)

Protocols SCSI-FCP,FCP-2,FCP-3,FC-SP(SeeDocumentation)forfulllistofsupportedprotocols.

Topology Point-to-point(N_Port),switchedfabric(N_Port),includingN_PortTrunkingwithframe-basedloadbalancing, FC-AL, and FC-AL2

Class of service Class3,Class2controlframessupported

Dynamic Fabric Provisioning (DFP)

DFPforFibreChannelFabricAssignedWorldwideName(FA-WWN)

Diagnostic Port (D_Port)

Port type enabling rapid isolation of optics or cable problems

Boot-over-SAN DAS(point-to-pointtopology)anddiskless Fabric-based LUN discovery

LUN masking Initiator-basedLUNmaskingforstoragetrafficisolation

Target rate limiting Throttlestrafficbasedontarget’s(slower)speedcapability

Distancesupport Brocade415/425

• 70metersat4Gbpson62.5/125μmMMF

• 150metersat4Gbpson50/125μmOM2MMF

• 380metersat4Gbpson50/125μmOM3MMF

Brocade815/825

• 21metersat8Gbpson62.5/125μm Multi-ModeFiber(MMF)

• 50metersat8Gbpson50/125μmOM2MMF

• 150metersat8Gbpson50/125μmOM3MMF

Page 4: DATA SHEET BROCADE 415, 425, 815, AND 825 ...€¦ · ERER CONNECTIITY DATA SHEET BROCADE 415, 425, 815, AND 825 FIBRE CHANNEL HBAs HIGHLIGHTS • Centralizes management across the

DATA SHEET www.brocade.com

©2012BrocadeCommunicationsSystems,Inc.AllRightsReserved.09/12GA-DS-1478-02

ADX,Brocade,BrocadeAssurance,BrocadeOne,theB-wingsymbol,DCX,FabricOS,ICX,MLX,MyBrocade,SANHealth,VCS,andVDXareregisteredtrademarks,andAnyIO,HyperEdge,NETHealth,OpenScript,andTheEffortlessNetworkaretrademarksofBrocadeCommunicationsSystems,Inc.,intheUnitedStatesand/orinothercountries.Otherbrands,products,orservicenamesmentionedmaybetrademarksoftheirrespectiveowners.

Notice:Thisdocumentisforinformationalpurposesonlyanddoesnotsetforthanywarranty,expressedorimplied,concerninganyequipment,equipmentfeature,orserviceofferedortobeofferedbyBrocade.Brocadereservestherighttomakechangestothisdocumentatanytime,withoutnotice,andassumesnoresponsibilityforitsuse.Thisinformationaldocumentdescribesfeaturesthatmaynotbecurrentlyavailable.ContactaBrocadesalesofficeforinformationonfeatureandproductavailability.ExportoftechnicaldatacontainedinthisdocumentmayrequireanexportlicensefromtheUnitedStatesgovernment.

Corporate Headquarters SanJose,CAUSAT:[email protected]

European Headquarters Geneva,SwitzerlandT:+41-22-799-56-40 [email protected]

Asia Pacific Headquarters SingaporeT:+65-6538-4700 [email protected]

READYC E R T I F I E D

Agency ApprovalsUnitedStates Bi-NatUL/CSA60950-11stEd;ANSI

C63.4;cCSAus;FCCClassB

Canada Bi-NatUL/CSA60950-11stEd;ICES-003ClassB;cCSAus

Japan CISPR22ClassBandJEIDA(Harmonics);VCCI-B

EuropeanUnion EN60950-1;EN55022ClassBandEN55024;TUVBauart,CEMark

Australia,NewZealand EN55022andCISPR22ClassBorAS/NZSCISPR22;C-Tick

Russia IEC60950-1;51318.22-99and 24-99;GOSTMark

Korea KN22andKN24;MICMarkClassB

Taiwan CNS14336(94);CNS13438(95)ClassA;BSMIMark

Environmental and Power RequirementsAirflow Noairflowrequired

Operatingtemperature Non-operatingtemperature

0ºC/32ºFto55ºC/131ºF(drybulb) −43ºC/−40ºFto73ºC/163ºF(drybulb)

Operatinghumidity Non-operatinghumidity

5%to93%(relative,non-condensing) 5%to95%(relative,non-condensing)

Power dissipation 6W(fulllinerate)

Operating voltage 3.3V

Host SpecificationsServerplatform Intel(IA32,IEM64T),AMD(x86,64),andSun(x86,

SPARC)

Serverchipset Intel,nVidia,ServerWorks/Broadcom,AMD/ATI, andSPARC

Businterface PCIExpressGen2.0(x8)andGen3.0compatible,withMSI-XandINTx

SoftwareManagement Brocade Network Advisor (Professional,

ProfessionalPlus,Enterprise),including multiplehostdriverupdates

Brocade Host Connectivity Manager (HCM)Command Line Interface (CLI)

Driver- and HCM-supportedoperatingsystems

MicrosoftWindows,RedHatLinux,SUSELinux,OracleLinuxandOracleSolaris,VMware(ESX/ESXi),MicrosoftHyper-V,OracleVM,CitrixXenServer,XenforRedHat,XenforSUSE

APIs SNIA-HBA-API2.0andFDMI-I

Warranty and SupportThree years advance replacement hardware warrantywith24×7×365telephone/e-mailsupportandlifetimesoftwareupdates

Physical Specifications

Transceivers Brocade415/425:4GbpsFibreChannel LC-stylepluggable(SFP),MMF(850nm), hot-swappable

Brocade815/825:8GbpsFibreChannelLC-stylepluggable(SFP+),MMF(850nm),hot-swappable

Form factor PCIExpresslow-profileformfactor; 16.77cm×6.89cm(6.60in.×2.71in.)

Bracket size Standard:1.84cm×12.08cm (0.73in.×4.76in.) Lowprofile:1.84cm×8.01cm (0.73in.×3.15in.)