1301 North Euclid Avenue Princeton, Illinois 61356 USA Phone 888/436-5499 Fax 815/872-0421 E-mail: [email protected] www.championpneumatic.com Due to Champion’s continuing product development program, specifications and materials are subject to change without notice or obligation. Member of © 2005 Gardner Denver, Inc. Printed in U.S.A. CA18-2-225, 4th Edition 3/05 CRN SERIES REFRIGERATED DRYER-FILTER SPECIFICATIONS Integral Coalescing Filter Specifications Genuine Replacement Elements* Model Rated Standard Connection Dimensions Weight w/Oil Voltages HP Cold coalescing Oil removing CRN Flow I-Controller [inches] [inches] [lbs] Removal [V/ph/Hz] Standard package packages* include the following (1) (2) (3) H W D Filter includes 3 micron 3 micron 0.008 ppm w/w (4) [lbs] grade B element* grade B element* Grade E element* Model Qty Model Qty Model Qty 10 10 n/a 3/8 OD 15 12.6 12.6 64 115/1/60 1/7 - - - - - - 15 15 3/8 OD 15 12.6 12.6 69 1/7 - - - - - - 25 25 1/2 NPT 26 19 21 142 147 1/6 FIL14BE 1 FIL14BE 1 FIL14EE 1 35 35 I-Controller 1/2 NPT 26 19 21 146 151 115/1/60 1/5 FIL14BE 1 FIL14BE 1 FIL14EE 1 50 50 Level 1 1/2 NPT 26 19 21 152 157 208-230/1/60 1/4 FIL16BE 1 FIL16BE 1 FIL16EE 1 75 75 3/4 NPT 33 25 26 209 216 220-240/1/50 1/3 FIL18BE 1 FIL18BE 1 FIL18EE 1 100 100 3/4 NPT 33 25 26 228 235 1/2 FIL18BE 1 FIL18BE 1 FIL18EE 1 125 125 1 NPT 33 25 26 229 237 3/4 FIL20BE 1 FIL20BE 1 FIL20EE 1 150 150 1 NPT 33 25 26 244 252 3/4 FIL20BE 1 FIL20BE 1 FIL20EE 1 200 200 1-1/2 NPT 40 32 32 410 423 1 FIL22BE 1 FIL22BE 1 FIL22EE 1 250 250 I-Controller 1-1/2 NPT 40 32 32 410 423 11/2 FIL22BE 1 FIL22BE 1 FIL22EE 1 300 300 Level 2 1-1/2 NPT 49 32 48 631 644 11/2 FIL24BE 1 FIL24BE 1 FIL24EE 1 400 400 2 NPT 49 32 48 672 704 11/2 FIL26BE 1 FIL26BE 1 FIL26EE 1 500 500 2-1/2 NPT 49 32 48 701 733 208-230/3/60 2 FIL26BE 1 FIL26BE 1 FIL26EE 1 750 750 2-1/2 NPT 56 32 52 968 1038 460/3/60 3 FIL24BE 2 FIL24BE 2 FIL24EE 2 1000 1000 4 ANSI flange 85 48 49 1720 1747 575/3/60 6 GE9-36 4 GE9-36 4 GE5-36 4 1250 1250 4 ANSI flange 85 48 49 1740 1767 380-420/3/50 7.5 GE9-36 4 GE9-36 4 GE5-36 4 1500 1500 I-Controller 4 ANSI flange 85 48 49 1850 1877 9 GE9-36 4 GE9-36 4 GE5-36 4 1750 1750 Level 4 6 ANSI flange 85 54 56 2000 2054 10 GE9-36 8 GE9-36 8 GE5-36 8 2000 2000 6 ANSI flange 85 54 56 2100 2154 12 GE9-36 8 GE9-36 8 GE5-36 8 2500 2500 6 ANSI flange 85 54 56 2238 2292 15 GE9-36 8 GE9-36 8 GE5-36 8 3000 3000 6 ANSI flange 85 54 56 2263 2317 17.5 GE9-36 8 GE9-36 8 GE5-36 8 208-230/3/60 460/3/60 575/3/60 380-420/3/50 * Consult your local Distributor for information on complete maintenance kits Refrigerant: CRN10-CRN750 use R-134a, models CRN1000-CRN3000 use R-404a Maximum operating pressure: 250 PSIG for packages with I-Controller Level 1 & 2: 232 PSIG for packages with I-Controller Level 3 & 4 Maximum operating temperature: 120°F: 140°F with SURE-SAVE cooling injection option (1) Rated Flow Capacity - Conditions for rating dryers are in accordance with CAGI (Compressed Air and Gas Institute) Standard ADF100: Refrigerated Compressed Air Dryers - Methods for Testing and Rating. Conditions for rating above dryers are: compressed air at dryer inlet: 100 psig and 100°F saturated; ambient temperature: 100°F; operating on 60 Hz power supply. At rated conditions, outlet pressure dew point is 38°F (2) I-Controller Level 4 is standard on CRN1000-CRN3000 I-Controller Level 3 is available on CRN200-CRN750 I-Controller Level 2 is standard on CRN125-CRN750 I-Controller Level 1 is available on CRN25-CRN100 (3) OD connection is tubing: NPT connections are male (4) Add 2 inches for Inlet/Outlet connections (does not apply to CRN10-CRN15 nor CRN1000- CRN3000) NOTES a. I-Controller Level 1 includes: Power on LED, Compressor on LED, On/Off switch, dew point bar graph display, pneumatic pilot-operated drain b. I-Controller Level 2 includes: Power on LED, Compressor on LED, On/Off switch, dew point bar graph display, timed solenoid drain with push to test button (1) CSA and CE certified (2) NEMA 1 standard c. I-Controller Level 3 includes: Power on LED, process flow diagram with LED indicators, auto restart, remote start/stop, Vacuum Fluorescent Text Display, compressor run time, °F/°C selectable temperature readings for Inlet Air, Dew Point, and Ambient Air. Vivid yellow LED to advise when scheduled maintenance is due, and warn if high ambient or inlet air temperatures warrant attention. Alarm Mode triggers a bright red LED, initializes alarm relay and text displays fault condition. Downloadable memory stores details of the last 10 alarm events (e.g., date, time, fault.) English, Spanish, French language selectable, RS-485 & RS-232 ports for remote communications, and electric Demand Drain. d. I-Controller Level 4 includes: Power on LED, Compressor on LED, On/Off switch, dew point bar graph display, manual or schedule operating modes to synchronize to your workday, auto restart, text display window that displays current time, operating mode, total operating hours, hours to service, operator alert LED, English, Spanish, German, French and Italian language selectable, RS-232 communication capable, fault condition diagnostics with text display, integral blowgun/hose assembly, demand drain with push-to-test button. e. An additional drain valve, consistent with type supplied with package I-Controller, is supplied when Cold Coalescing Oil Removal Filter option is specified. f. Units are air-cooled as standard. Contact your local Distributor if water-cooled versions are required. TABLE 1 - Correction Factors (Multipliers) for Inlet Air Temperature and Pressure TABLE 2 - Correction Factors for Ambient Temperature To adjust dryer capacity for conditions other than rated, use Correction Factors (multipliers) from Tables 1, 2 and 3. Example: What is the capacity of a model CRN100 when the compressed air at the inletåryer is at 150 psig and 100°F , the ambient temperature is 90°F and a 50°F dew point is desired? Answer: 100 scfm (rated flow from Specifications Table) x 1.13 (correction factor for inlet temperature and pressure from Table 1) x 1.06 (correction factor for ambient temperature from Table 2) x 1.3 (correction factor for dew point from Table 3) = 156 scfm INLET INLET TEMPERATURE PRESSURE 80°F 90°F 100°F 110°F 120°F (PSIG) (27°C) (32°C) (38°C) (43°C) (49°C) 50 1.35 1.05 0.84 0.69 0.56 80 1.50 1.17 0.95 0.79 0.66 100 1.55 1.23 1.00 0.82 0.70 125 1.63 1.31 1.07 0.91 0.74 150 1.70 1.37 1.13 0.95 0.80 175 1.75 1.42 1.18 0.99 0.84 200 1.80 1.47 1.22 1.03 0.89 AMBIENT 80°F 90°F 100°F 110°F TEMPERATURE (27°C) (32°C) (38°C) (43°C) Multiplier 1.12 1.06 1.00 0.94 DEW POINT 38°F 40°F 45°F 50°F TEMPERATURE (3°C) (4°C) (7°C) (10°C) Multiplier 1.0 1.1 1.2 1.3 TABLE 3 - Correction Factors for Dew Point Temperature

CRN SERIES REFRIGERATED DRYER-FILTER ...ambtools.com/web-content/pdf/champion/champion_crn.pdfrestart, remote start/stop, Vacuum Fluorescent Text Display, compressor run time, F/ C

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CRN SERIES REFRIGERATED DRYER-FILTER ...ambtools.com/web-content/pdf/champion/champion_crn.pdfrestart, remote start/stop, Vacuum Fluorescent Text Display, compressor run time, F/ C

1301 North Euclid AvenuePrinceton, Illinois 61356 USAPhone 888/436-5499Fax 815/872-0421E-mail: [email protected]

Due to Champion’s continuing product development program,specifications and materials are subject to change withoutnotice or obligation.

Member of

© 2005 Gardner Denver, Inc.Printed in U.S.A.CA18-2-225, 4th Edition 3/05

CRN SERIES REFRIGERATED DRYER-FILTER SPECIFICATIONS

Integral Coalescing Filter SpecificationsGenuine Replacement Elements*

Model Rated Standard Connection Dimensions Weight w/Oil Voltages HP Cold coalescing Oil removingCRN Flow I-Controller [inches] [inches] [lbs] Removal [V/ph/Hz] Standard package packages* include the following

(1) (2) (3) H W D Filter includes 3 micron 3 micron 0.008 ppm w/w(4) [lbs] grade B element* grade B element* Grade E element*

Model Qty Model Qty Model Qty

10 10 n/a 3/8 OD 15 12.6 12.6 64 115/1/60 1/7 - - - - - -15 15 3/8 OD 15 12.6 12.6 69 1/7 - - - - - -25 25 1/2 NPT 26 19 21 142 147 1/6 FIL14BE 1 FIL14BE 1 FIL14EE 135 35 I-Controller 1/2 NPT 26 19 21 146 151 115/1/60 1/5 FIL14BE 1 FIL14BE 1 FIL14EE 150 50 Level 1 1/2 NPT 26 19 21 152 157 208-230/1/60 1/4 FIL16BE 1 FIL16BE 1 FIL16EE 175 75 3/4 NPT 33 25 26 209 216 220-240/1/50 1/3 FIL18BE 1 FIL18BE 1 FIL18EE 1100 100 3/4 NPT 33 25 26 228 235 1/2 FIL18BE 1 FIL18BE 1 FIL18EE 1125 125 1 NPT 33 25 26 229 237 3/4 FIL20BE 1 FIL20BE 1 FIL20EE 1150 150 1 NPT 33 25 26 244 252 3/4 FIL20BE 1 FIL20BE 1 FIL20EE 1200 200 1-1/2 NPT 40 32 32 410 423 1 FIL22BE 1 FIL22BE 1 FIL22EE 1250 250 I-Controller 1-1/2 NPT 40 32 32 410 423 11/2 FIL22BE 1 FIL22BE 1 FIL22EE 1300 300 Level 2 1-1/2 NPT 49 32 48 631 644 11/2 FIL24BE 1 FIL24BE 1 FIL24EE 1400 400 2 NPT 49 32 48 672 704 11/2 FIL26BE 1 FIL26BE 1 FIL26EE 1500 500 2-1/2 NPT 49 32 48 701 733 208-230/3/60 2 FIL26BE 1 FIL26BE 1 FIL26EE 1750 750 2-1/2 NPT 56 32 52 968 1038 460/3/60 3 FIL24BE 2 FIL24BE 2 FIL24EE 21000 1000 4 ANSI flange 85 48 49 1720 1747 575/3/60 6 GE9-36 4 GE9-36 4 GE5-36 41250 1250 4 ANSI flange 85 48 49 1740 1767 380-420/3/50 7.5 GE9-36 4 GE9-36 4 GE5-36 41500 1500 I-Controller 4 ANSI flange 85 48 49 1850 1877 9 GE9-36 4 GE9-36 4 GE5-36 41750 1750 Level 4 6 ANSI flange 85 54 56 2000 2054 10 GE9-36 8 GE9-36 8 GE5-36 82000 2000 6 ANSI flange 85 54 56 2100 2154 12 GE9-36 8 GE9-36 8 GE5-36 82500 2500 6 ANSI flange 85 54 56 2238 2292 15 GE9-36 8 GE9-36 8 GE5-36 83000 3000 6 ANSI flange 85 54 56 2263 2317 17.5 GE9-36 8 GE9-36 8 GE5-36 8

208-230/3/60460/3/60575/3/60

380-420/3/50

* Consult your local Distributor for information on complete maintenance kitsRefrigerant: CRN10-CRN750 use R-134a, models CRN1000-CRN3000 use R-404aMaximum operating pressure: 250 PSIG for packages with I-Controller Level 1 & 2: 232 PSIG forpackages with I-Controller Level 3 & 4 Maximum operating temperature: 120°F: 140°F with SURE-SAVE cooling injection option (1) Rated Flow Capacity - Conditions for rating dryers are in accordance with CAGI (Compressed Air

and Gas Institute) Standard ADF100: Refrigerated Compressed Air Dryers - Methods for Testingand Rating. Conditions for rating above dryers are: compressed air at dryer inlet: 100 psig and100°F saturated; ambient temperature: 100°F; operating on 60 Hz power supply. At ratedconditions, outlet pressure dew point is 38°F

(2) I-Controller Level 4 is standard on CRN1000-CRN3000I-Controller Level 3 is available on CRN200-CRN750I-Controller Level 2 is standard on CRN125-CRN750I-Controller Level 1 is available on CRN25-CRN100

(3) OD connection is tubing: NPT connections are male(4) Add 2 inches for Inlet/Outlet connections (does not apply to CRN10-CRN15 nor CRN1000-

CRN3000)

NOTES a. I-Controller Level 1 includes: Power on LED, Compressor on LED, On/Off switch, dew point bar

graph display, pneumatic pilot-operated drainb. I-Controller Level 2 includes: Power on LED, Compressor on LED, On/Off switch, dew point bar

graph display, timed solenoid drain with push to test button(1) CSA and CE certified(2) NEMA 1 standard c. I-Controller Level 3 includes: Power on LED, process flow diagram with LED indicators, auto

restart, remote start/stop, Vacuum Fluorescent Text Display, compressor run time, °F/°Cselectable temperature readings for Inlet Air, Dew Point, and Ambient Air. Vivid yellow LED toadvise when scheduled maintenance is due, and warn if high ambient or inlet air temperatureswarrant attention. Alarm Mode triggers a bright red LED, initializes alarm relay and textdisplays fault condition. Downloadable memory stores details of the last 10 alarm events(e.g., date, time, fault.) English, Spanish, French language selectable, RS-485 & RS-232 portsfor remote communications, and electric Demand Drain.

d. I-Controller Level 4 includes: Power on LED, Compressor on LED, On/Off switch, dew point bargraph display, manual or schedule operating modes to synchronize to your workday, autorestart, text display window that displays current time, operating mode, total operating hours,hours to service, operator alert LED, English, Spanish, German, French and Italian languageselectable, RS-232 communication capable, fault condition diagnostics with text display,integral blowgun/hose assembly, demand drain with push-to-test button.

e. An additional drain valve, consistent with type supplied with package I-Controller, is suppliedwhen Cold Coalescing Oil Removal Filter option is specified.

f. Units are air-cooled as standard. Contact your local Distributor if water-cooled versions arerequired.

TABLE 1 - Correction Factors (Multipliers) for Inlet Air Temperature and Pressure

TABLE 2 - Correction Factors for Ambient Temperature

To adjust dryer capacity for conditions other than rated, use Correction Factors (multipliers) fromTables 1, 2 and 3.Example: What is the capacity of a model CRN100 when the compressed air at the inletåryer is at 150psig and 100°F , the ambient temperature is 90°F and a 50°F dew point is desired? Answer: 100 scfm (rated flow from Specifications Table) x 1.13 (correction factor for inlet temperatureand pressure from Table 1) x 1.06 (correction factor for ambient temperature from Table 2) x 1.3(correction factor for dew point from Table 3) = 156 scfm

INLET INLET TEMPERATURE

PRESSURE 80°F 90°F 100°F 110°F 120°F

(PSIG) (27°C) (32°C) (38°C) (43°C) (49°C)

50 1.35 1.05 0.84 0.69 0.5680 1.50 1.17 0.95 0.79 0.66100 1.55 1.23 1.00 0.82 0.70125 1.63 1.31 1.07 0.91 0.74150 1.70 1.37 1.13 0.95 0.80175 1.75 1.42 1.18 0.99 0.84200 1.80 1.47 1.22 1.03 0.89

AMBIENT 80°F 90°F 100°F 110°F

TEMPERATURE (27°C) (32°C) (38°C) (43°C)

Multiplier 1.12 1.06 1.00 0.94

DEW POINT 38°F 40°F 45°F 50°F

TEMPERATURE (3°C) (4°C) (7°C) (10°C)

Multiplier 1.0 1.1 1.2 1.3

TABLE 3 - Correction Factors for Dew Point Temperature

Page 2: CRN SERIES REFRIGERATED DRYER-FILTER ...ambtools.com/web-content/pdf/champion/champion_crn.pdfrestart, remote start/stop, Vacuum Fluorescent Text Display, compressor run time, F/ C

CR

NS

erie

sR

efrig

erated

Compressed A

ir D

ryers

Leading Technology.Leading Technology.

10–3000

SCFM

Page 3: CRN SERIES REFRIGERATED DRYER-FILTER ...ambtools.com/web-content/pdf/champion/champion_crn.pdfrestart, remote start/stop, Vacuum Fluorescent Text Display, compressor run time, F/ C

Durability DeliveredCRN Series Refrigerated Air Dryers

2

CRN Series refrigerated air dryers are engineered to benefit you today and tomorrow from the tradition ofdurability that is Champion. Quality components and engineering excellence meld to ensure you of astable 38°F pressure dew point. These exclusive compressed air preparation packages combine reliability,cutting-edge design, and innovative packaging into a single space saving unit. The air quality deliveredfrom an CRN Series dryer may define the difference between moderate and superior results from yourplant’s processes or systems.

CRN Series dryers benefit you with:

Four levels of Intelligence Controller (I-Controller) packages to allow you to customize the CRNSeries dryers to meet your specific requirements. This lets you choose which I-Controller packagerepresents your best value.

Select Heat Exchanger arrangements to ensure you get the right combination of value and efficiencyin every size. This secures your investment today and tomorrow with energy efficiency and the bestwarranties in the industry.

Combination Separator/Filter that incorporates our 99% efficient 3 micron Grade B elements. Thisensures you of consistent water removal (especially under low flow conditions) to maintain a stable38°F dew point within each flow range.

AIR TREATMENT SYSTEMS The flexibility engineered into every CRN Series dryer allows you to satisfy your air quality requirementswith a single package. Enlist us to deliver the dew point stability, air quality, energy efficiency, andproduct reliability that you expect from Champion.

ISO 8573.1 AIR QUALITY CLASSES1992 earmarked the year the International Organization for Standardization (ISO) established ISO 8573.1as the global benchmark for evaluating the quality of compressed air. Thus, providing engineers with auniversally accepted unit of measure for quantifying compressed air stream contaminants. Namely SolidParticulates, Moisture, and Oil.

STANDARDS PER ISO 8573.1

CRN Series packages deliver:

ISO 8573.1 QUALITY CLASS RATINGS

1

2

3

1

Optionalexternal

Grade G Filtershown attached.

* Quality Class 0 reflects "as specified" level of cleanliness. The addition of anoptional external Grade G Filter achieves 0.003 ppm w/w for technically Oil-Free air.

3

2

Solid Contaminants Maximum Pressure Maximum Oil Content Quality (maximum particle Dew Points (droplets, aerosols, and Classes size in microns) °F (°C) vapor ppm w/w (mg/m3)

0 as specified as specified as specified1 0.1 -94 (-70) 0.008 (0,01)2 1 -40 (-40) 0.08 (0,1)3 5 -4 (-20) 0.8 (1)4 15 38 (3) 4 (5)5 40 45 (7) 21 (25)6 – 50 (10) –

CRN Series Solids Moisture Oil

As Standard 3 4 5

with Cold Coalescer Option 1 4 1

with an optional external Grade G CFF Filter (shown attached) 1 4 0*

Page 4: CRN SERIES REFRIGERATED DRYER-FILTER ...ambtools.com/web-content/pdf/champion/champion_crn.pdfrestart, remote start/stop, Vacuum Fluorescent Text Display, compressor run time, F/ C

InstrumentationPower-on LED and 6 foot grounded power cord are standard on all single-phase 115-voltunits. Easy view angular instrumentation panels prominently display all I-Controllersinstrumentation packages.

Oil Removal… this option integrates our factory installed Grade E Cold CoalescingOil Removal Filter. Oil droplets and aerosols are extracted from the air stream in cleaning itdown to 0.008 ppm w/w and solids are retained down to 0.01 micron. CRN Series dryers thatinclude the Cold Coalescing Oil Removal Filter option are also equipped with a dedicateddrain trap. Drain trap is consistent with the type provided with your chosen I-Controller.Available on models CRN25-CRN3000.

SURE-SAVE… this option guards the refrigeration compressor from extreme operatingtemperatures. Excessive summer heat, dirty condensers, or poorly ventilated compressorrooms may threaten the operation or longevity of the refrigeration compressor. Rather thanrisk an unscheduled shutdown, factory installed Sure-Save cooling injection provides heatrelief to help protect your investment from up to 140°F inlet air temperatures. It is availableas an option with the I-Controller Level 2 and Level 3 models.

NEMA 4/12… this option provides factory installed electrical enclosures that offerprotection from the elements. NEMA 4/12 enclosures are ideal for those outdoor installationsor, when dryer will be installed in a “wash down” type of environment where contact withwater spray is prevalent. NEMA 4/12 enclosures are available as an option on modelsCRN50–CRN3000.

LOW AMBIENT… this option protects the dryer from internal damage due to freezingtemperatures down to -10°F. Factory installed package includesheat trace tape and fan control kit.

GAUGES… three individual gauge options areavailable to identify: Inlet Air Pressure, RefrigerantSuction Pressure, and Refrigerant Discharge Pressure.Factory installed gauges provide you with systeminformation that helps ensure your system is operatingproperly and simplifies troubleshooting.

7

Option Feature Overview

LED Indicator lights Drain Valves System Upgrades

Control Power- Compressor- Dew Point Pneumatic Timed Demand Cold Sure-Save Vacuum Version on on Graph Pilot- Drain w/ Drain w/ Coalescing Heat Fluorescent

Operated Push-to- Push-to- Oil Removal Reliever Text Displaytest* test* Filter

I-Controller Level 1 S S S S - - O - -

I-Controller Level 2 S S S - S - O O -

I-Controller Level 3 S S - - - S O O S

I-Controller Level 4 S S S - - S O - S

S = Standard FeatureO = Optional Feature* Secondary manual drains

complete with by-pass valvesare standard equipment andonly available on packageswith Level 2, Level 3, andLevel 4 I-Controllers. Thishelps keep the area clean anddry and helps you avoid dryershutdown during drain valvemaintenance.

System Options

Page 5: CRN SERIES REFRIGERATED DRYER-FILTER ...ambtools.com/web-content/pdf/champion/champion_crn.pdfrestart, remote start/stop, Vacuum Fluorescent Text Display, compressor run time, F/ C

CRN Series dryers are equipped with control schemes thatare designed to provide you with the most value deliveredwithin each flow range. Engineered with industry leadingfeatures, each I-Controller package provides just the rightlevel of benefits to appeal to the most demandingapplications and discriminating customers.

INSTRUMENTATIONPower-on LED and 6 foot grounded power cord are standardon all single-phase 115-volt units. Easy view angularinstrumentation panels prominently display all I-Controllers instrumentation packages

I-CONTROLLER LEVEL 1

Standard equipment on models CRN25 through CRN100 includes:“Power-on” LED, “Compressor-on” LED, On/Off rocker switch, dew pointbar graph LED display and, pneumatic pilot-operated drain trap.

I-CONTROLLER LEVEL 2

Standard equipment* on models CRN125 through CRN750 includes:“Power-on” LED, “Compressor-on” LED, On/Off rocker switch, dew pointbar graph LED display. Timed solenoid drain trap with push-to-testbutton and secondary manual drains complete with by-pass valves anddrain lines are standard equipment. This helps keep the surroundingarea clean and dry and helps you avoid having to shutdown the dryerduring drain valve maintenance.

*Optional on models CRN25 through CRN100.4

Take Control

Page 6: CRN SERIES REFRIGERATED DRYER-FILTER ...ambtools.com/web-content/pdf/champion/champion_crn.pdfrestart, remote start/stop, Vacuum Fluorescent Text Display, compressor run time, F/ C

Compare these features—Unmatched in the industry!

5

I-CONTROLLER LEVEL 3

Optional equipment on models CRN200 through CRN750 includes: LEDindicated process diagram, auto restart, remote start/stop, compressorrun time, °F/°C selectable temperature readings for Inlet Air, DewPoint, and Ambient Air. Vivid yellow LED to advise when scheduledmaintenance is due, and warn if high ambient or inlet air temperatureswarrant attention. Alarm Mode triggers a bright red LED, dry contactsfor high dew point remote alarm at 55ºF. Downloadable memory storesdetails of the last 10 alarm events (e.g., date, time, fault.) English,Spanish, French language selectable, RS-485 & RS-232 communicationcapable. Demand Drain with push-to-test button and secondary manualdrains complete with by-pass valves and drain lines are standardequipment. This helps keep the surrounding area clean and dry andhelps you avoid having to shutdown the dryer during drain valvemaintenance.

I-CONTROLLER LEVEL 4

Standard equipment on models CRN1000 through CRN3000 includes:manual mode, schedule mode to synchronize operation to your workday,auto restart, text display window that displays current time, operatingmode, total operating hours, hours to service, dew point bar graph LEDdisplay, initializes alarm relay, operator alert light, English, Spanish,German, French and Italian language selectable, RS-232 communicationcapable, fault condition diagnostics with text display, demand drainwith push-to-test button, dry contacts for high dew point remote alarmat 55ºF.

WED 14:57SCHEDULE RUNNING

Page 7: CRN SERIES REFRIGERATED DRYER-FILTER ...ambtools.com/web-content/pdf/champion/champion_crn.pdfrestart, remote start/stop, Vacuum Fluorescent Text Display, compressor run time, F/ C

6

Refrigeration Circuit

CRN 25–3000 Series dryers enlist proven components andmodern materials to deliver the durability you expect fromChampion. Hot, moist incoming compressed air enters thePrecooler/Reheater (1) where it is precooled by the colddehydrated airstream. Environmentally friendly low-pressurerefrigerant gas is pressurized in the refrigeration compressor (2)Once compressed into a high-pressure gas, it then flows throughthe condenser (3) and changes to a cold 35°F liquid. The thermalexpansion valve (4) precisely meters the cold liquid refrigerant intothe evaporator (5) where the work is done. Hot, saturatedcompressed air enters the evaporator at the end opposite theincoming liquid refrigerant. The compressed air is chilled as theycross paths. Water is condensed out of the cold exiting air and isefficiently removed in the Separator/3 micron Filter (6). The coldair stream then flows through (7) the Cold Coalescing Oil RemovalFilter (optional on models CRN25-CRN3000) where oil droplets andaerosols to 0.008 ppm w/w are captured and removed. The exitingcold, dry compressed air then reenters the Precooler/Reheater (1)where it is reheated by the hot incoming air to prevent pipesweating in your plant. Finally, the warm refrigerant is now a low-pressure gas and returns to the suction-side (8) of the refrigerationcompressor to continue the process.

SURE-SAVE cooling injection (optional on models CRN125 – CRN750only) protects the refrigeration compressor during extreme heatevents. When high-inlet air temperatures (up to 140°F) threatenthe refrigeration compressor, SURE-SAVE (9) injects cooling reliefinto the suction-side (8) of the refrigeration circuit. This lowersthe return gas temperature to compensate for the higher inlet airtemperature and sustains operation.

CRN 10–15

Warm saturated air enters the Evaporator (A), where it is cooled byan air-to-refrigerant process. Water vapor condenses into a liquidfor removal at the moisture separator (B) by an Automatic Drain(C). The cold, dry air is reheated as it passes through the Reheater(D) while the patented Static Condenser (E) radiates waste heat toambient. This eliminates the need for a cooling fan and preventspipeline sweating at the air outlet.

A Constant Pressure (F) Expansion Valve (CPEV) modulates the flowof liquid refrigeration to the Evaporator (A). This eliminates freeze-ups and assures continuous, automatic dew point control. The CPEVresponds to pressure changes as the refrigerant leaves theEvaporator. This maintains the proper cooling rate under all loadconditions. The CPEV is adjusted at the factory to deliver automaticoperation.

1

2

3

4

5

1

2

3

4

5

67

89

6

7

8

9

(A)

Evaporator

(C)Automatic

Condensate Drain

(E)Static

Condenser

(F)Constant PressureExpansion Valve

(B)Moisture Separator

(D)Reheater

Evaporator

Moisture Separator

Automatic Drain

Reheater

Static Condenser

Constant Pressure Expansion Valve

A

B

C

D

E

F

Precooler/Reheater

Refrigeration Compressor

Condenser

Thermal Expansion Valve

Evaporator

Moisture Separator/3 micron Filter

Optional Cold Coalescing Oil Removal Filter

Suction-side

SURE-SAVE

Page 8: CRN SERIES REFRIGERATED DRYER-FILTER ...ambtools.com/web-content/pdf/champion/champion_crn.pdfrestart, remote start/stop, Vacuum Fluorescent Text Display, compressor run time, F/ C

BUILT TO PERFORM

PACKAGE DESIGNAt first glance, the ruggedness and ease of serviceabilityengineered into CRN Series becomes apparent. Fabricated fromsolid steel, the corrosion resistant epoxy powder paint and thefit and finish of the cabinet, foretell of the quality to befound within. At the touch of a button, quick fastenersrelease each lift out door panel. Easy interior access anduser-friendly serviceability translate to reduced maintenancecosts.

PROVEN PERFORMANCEAll models use reliable refrigeration compressors andenvironmentally friendly refrigerants. Models through CRN750use proven reciprocating refrigeration compressors and R-134arefrigerant. CRN1000 through CRN3000 incorporate ruggedscroll compressors and R-404a refrigerant. You benefit fromlong component life, and exceptional around-the-clockperformance.

HEAT TRANSFERCRN Series models 25-3000 incorporate heat exchangerscrafted from multiple offset layers of press formed AISI 316stainless steel. Press forming creates peaks and valleys thatform media channels that are rich in fluid turbulence. Thisprevents fouling and maximizes energy efficiency.

MAXIMUM EXTRACTION SEPARATOR/ FILTEREffective moisture removal at all flow rates is the key topreserve dew point stability. CRN25 and larger includes GradeB two-stage cold filtration to ensure maximum waterextraction even under low flow conditions. Stage onemechanically entraps solids >10 microns with dual stainlesssteel orifice tubes. Stage two utilizes in-depth fiber media tocoalesce water droplets and retain solid particles 3 micronsand larger.

GET CONNECTEDThe extended inlet/outlet connections on CRN dryers (CRN25-CRN750) were engineered with foresight to readily accept allCFF Series Filters without the need for cumbersome adaptorsand fittings. You gain the installation flexibility you needtoday that may help you be prepared to meet the changes oftomorrow.

CRN 10-15The patented static condenser technology eliminates the needfor a cooling fan. These models include an on/off switch,longer power cord (8 ft), a timer operated drain valve withisolation valve on CRN15 ,a float trap on CRN10, and deliverheated outlet air to eliminate sweaty piping.

* Lifetime Heat Exchanger warranty requires an CFF Series prefilter on theinitial purchase and annual filter element replacement with a genuine CFFSeries element. Standard warranty is 5 years on Heat Exchangers.