MEDICAL EDUCATION ACADEMIA MEDICAL EDUCATION ACADEMIA COREVALVE ® AND EVOLUT ® R SYSTEMS OVERVIEW THE INFORMATION IN THIS DOCUMENT IS INTENDED FOR EDUCATIONAL PURPOSES AND IS NOT MEANT AS A SUBSTITUTE FOR THE INSTRUCTIONS FOR USE OR PRODUCT TRAINING. PRACTICE MAY VARY BASED ON CLINICAL JUDGMENT. INTERNATIONAL. CAUTION: FOR DISTRIBUTION ONLY IN MARKETS WHERE COREVALVE EVOLUT R HAS BEEN APPROVED. NON DESTINE AU MARCHE FRANCAIS. ©MEDTRONIC, INC. 2015. ALL RIGHTS RESERVED. UC201601254a EE April, 2016

COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA MEDICAL EDUCATION ACADEMIA

COREVALVE® AND EVOLUT® R SYSTEMS OVERVIEW

THE INFORMATION IN THIS DOCUMENT IS INTENDED FOR EDUCATIONAL PURPOSES AND IS NOT MEANT AS A SUBSTITUTE FOR THE INSTRUCTIONS FOR USE OR PRODUCT TRAINING. PRACTICE MAY VARY BASED ON CLINICAL JUDGMENT. INTERNATIONAL. CAUTION: FOR DISTRIBUTION ONLY IN MARKETS

WHERE COREVALVE EVOLUT R HAS BEEN APPROVED. NON DESTINE AU

MARCHE FRANCAIS. ©MEDTRONIC, INC. 2015. ALL RIGHTS RESERVED.

UC201601254a EE April, 2016

Page 2: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

2 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

CONSISTENT DESIGN PROVEN IN MORE THAN 130,000 IMPLANTS WORLDWIDE

Self-Expanding Frame

Conforms and seals to the annulus

The foundation for recapturability

Supra Annular Valve Design

Maximize flow and optimize coaptation

Porcine Pericardial Tissue

Thinness for low profile delivery

Strength and pliability for long-term durability

Page 3: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

Superelasticity Performance

Compact designs and low delivery profile

Conformable to patient anatomy

Self-anchoring

Controlled retraction for precise delivery and placement

Maintains valve shape

Highly biocompatible

MR Conditional*

Proven fatigue performance

Shape Retention

3 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

FRAME MATERIAL SELECTION: NITINOL

* Refer to IFU for list of safe operating parameters

Page 4: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

4 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

SELF-EXPANDING FRAME DESIGN

Frame cells comprised of struts and nodes: Smallest cell accommodates a 10 Fr catheter for coronary access

Nodes appear as bands when compressed into the delivery system and are used to assess valve depth

Nodes

Strut

Cell

Page 5: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

PRODUCT DESIGN:

Conforming Frame The nitinol frame conforms and seals to the non-circular annulus.

Images courtesy of Drs. De Jaegere and Schultz, Erasmus MC, Rotterdam,

The Netherlands

5 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

CLINICAL NEED: STRONG HEMODYNAMIC PERFORMANCE MINIMIZING PARAVALVULAR LEAK

Page 6: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

6 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

CLINICAL NEED: STRONG HEMODYNAMIC PERFORMANCE MAXIMIZING BLOOD FLOW

PRODUCT DESIGN:

Supra-annular Valve Design

The supra-annular leaflet position optimizes orifice area and flow while preserving circularity and coaptation.

Page 7: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

7 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

TISSUE SELECTION: PORCINE PERICARDIUM

Porcine pericardium ensures optimal valve performance in a low delivery profile:

Approximately half as thick as bovine pericardium

Prevents tissue damage during loading, crimping, tracking, and deployment

Allows for low-profile delivery across all valve sizes1,2

1. Sacks MS. University of Pittsburgh, 2008. Data on File.

2. Braga-Vilela AS, et al., J Membr Biol. 2008 .

Porcine Pericardium Bovine Pericardium

Page 8: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

PRODUCT DESIGN:

14Fr Equivalent Delivery Profile Across All Evolut R Valve Sizes

The low profile of the CoreValve and Evolut R systems helps minimize trauma during delivery, allowing physicians to treat patients with small or calcified vasculature.

1. Genereux P, et al. Vascular complications after transcatheter aortic valve replacement: insights from the

PARTNER (Placement of Aortic Transcatheter Valve) trial. JACC 2012;60(12):1043-52.

2. Hayashida K, et al. Transfemoral aortic valve implantation. JACC Intv 2011;4(8):851-8.

3. Josep Rodés-Cabau. Next-Generation Balloon-Expandable Technology: SAPIEN 3. TCT 2012

Larger sheath size has been shown to increase

the rate of major vascular complications1

and mortality.2

8 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

CLINICAL NEED: LOW PROFILE ACCESS ACCESS THROUGH SMALL OR TORTUOUS ANATOMY

Page 9: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

EVOLUT R SYSTEM

Page 10: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

10 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

DEVICE & PATIENT SELECTION CRITERIA

Page 11: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

11 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

VALVE SIZING

Note: Measurements provided are approximate based on engineering specifications.

Frame Height: 49 mm

Skirt Length: 12 mm

31 mm

23 mm

44 mm

CoreValve 31mm

Page 12: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

The Enveo R Delivery System with 14Fr-Equivalent In-Line Sheath is indicated for vessels down to 5.0 mm

Evolut R DCS

12 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

DELIVERY CATHETER SYSTEMS

The 18 Fr CoreValve Accutrak Delivery system is indicated for vessels down to 6.0 mm

CoreValve DCS

Page 13: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

13 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

LOADED CAPSULE UNDER FLUOROSCOPY

CoreValve

Evolut R

6 mm

Note: Measurements provided are approximate based on engineering specifications.

Capsule Flare 10 mm

Radiopaque Marker Band

Radiopaque Marker Band

4 mm

4 mm

4 mm

Page 14: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

14 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

TARGET IMPLANT DEPTH

CoreValve Evolut R

Target implant depth is 3 - 5 mm

Midway between nodes 0 and 1 to just below node 1

Target implant depth is 4 - 6 mm

Between nodes 1 and 1.5

Page 15: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

Minimum Transarterial Access Vessel Diameters ≥ 5.0 mm

15 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

LOWEST DELIVERY PROFILE 14FR-EQUIVALENT SYSTEM WITH INLINE SHEATH

Page 16: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

94.7% Patients Treated via Transfemoral Access

16 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

LOWEST DELIVERY PROFILE NEARLY ALL PATIENTS TREATED VIA TRANSFEMORAL ACCESS

94.7%

5.3%

Implants by Access Route

Transfemoral Alternative Access

14-Fr Equivalent In-Line Sheath

Evolut R Global Clinical Trial Results (US IFU).

Page 17: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

17 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

CONTROL DURING DEPLOYMENT 1:1 RESPONSE

Shaft ‘Spines’

Cross section of catheter shaft (excluding the stability layer)

Catheter shaft ‘spines’ provide stability to reduce stretching or compressing of shaft to enable 1:1 Response

Page 18: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

Capsule Flare

EnVeo™ R DCS’s capsule flare and flexible catheter design enable uniform and controlled valve expansion and self-centering of the valve in the annulus

18 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

CONTROL DURING DEPLOYMENT SELF-CENTERING

Page 19: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

19 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

CONTROL DURING DEPLOYMENT SELF-CENTERING

Page 20: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

20 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

CONTROL DURING DEPLOYMENT ABILITY TO RECAPTURE AND REPOSITION

EnVeo R DCS provides option to recapture and reposition up to three times before reaching the ‘Point of No Recapture’*

* Up to 80% deployment

Tactile Indicator ~ 2/3 Deployment

Just Prior to Point of No Recapture ~ 80% Deployment*

Page 21: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

21 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

EXCEPTIONAL VALVE PERFORMANCE LOW PPM RATE

1. Accurate Positioning • 1:1 response with the ability to recapture and

reposition the valve

2. More Consistent Radial Force* 3. Atraumatic Inflow

Redesigned inflow to reduce force applied by the inflow tip

13.3% 30 Day New Pacemaker**

*Comparison to CoreValve device **Evolut R Global Clinical Trial

Page 22: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

22 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

EXCEPTIONAL VALVE PERFORMANCE ENHANCED SEALING

Enhanced Sealing with a More Conformable Frame 1. Increased Oversizing

2. More Consistent Radial Force

3. Extended Sealing Skirt *

Note: images may not be to exact scale and are for illustration purposes only. *CoreValve Evolut R 26 and 29 mm only **Evolut R Global Clinical Trial Results (US IFU).

Evolut R 29 mm

CoreValve 29 mm

6.8% Moderate & 0% Severe PVL**

Page 23: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

23 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

EASE OF USE IMPROVED FRAME RELEASE

Paddle attachment incorporates a nested paddle and pocket mechanism for release

Rounded paddle design provides a reliable release

Metal paddle attachment helps assess paddle detachment under fluoroscopy

Page 24: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA

24 CoreValve and Evolut R Systems Overview | Medtronic - Confidential

EASE OF USE ENVEO R PACKAGING

Packaging with Integrated Rinsing and Loading Bowls

Integrated Loading Bath

Removable Rinsing Bowls

Page 25: COREVALVE AND EVOLUT R SYSTEMS OVERVIEW

MEDICAL EDUCATION ACADEMIA MEDICAL EDUCATION ACADEMIA

MUCHAS GRACIAS!