38
Cordis Radial Solutions Integrated solutions for transradial care

Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

  • Upload
    others

  • View
    44

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

Important Information:Prior to use, refer to the “instructions for use” supplied with these devices for indications, contraindications, side effects, suggested procedure, warnings and precautions. As part of the Cordis policy of continuous product development we reserve the right to change product specifications without prior notification. Tel:+32 2 746 30 00 Fax:+32 2 746 34 05© Cordis Europe, a division of Johnson & Johnson Medical N.V. - November 2012 - 2E-800-1988-3

Cordis Radial SolutionsIntegrated solutions for transradial care

CORDIS® CARDIAC & VASCULAR INSTITUTEBVBA

Keep the wheel of knowledge turning

The mission of the CORDIS® CARDIAC & VASCULAR INSTITUTE

BVBA is to provide global healthcare

professionals the highest quality therapy education and medical device skills training. Cordis is committed to the development of educational opportunities for new procedures, techniques, and technology. For advances in education, clinical networking, and the sharing of resources to expand the breadth and depth of knowledge of global healthcare providers, Cordis offers an array of services.

Cordis Offers:

• Global Education Exchange Program

• Online Offerings

• Simulation

• Live Courses

Register for www.ccvi-online.com /EMEA and discover a network of expertise dedicated to advancing cardiac and vascular care.

Enhanced radial performance with full-service support

Sheath IntroducersA smooth first step to transradial procedures, with atraumatic access and excellent performance.

Diagnostic WiresAvailable in multiple cores, coatings, tips, diameters, and lengths to help ensure performance and safety.

Diagnostic CathetersBest-in-class catheters available in the widest selection of shapes — now including new transradial- specific shapes.

Guiding CathetersBalancing support, flexibility, and control for optimal access and backup with one of the broadest ranges of shapes and sizes available — now with new transradial-specific shapes.

ServicesCordis U-shape It Program allows you to modify our catheters to meet your specific needs.

Professional EducationCORDIS® CARDIAC & VASCULAR INSTITUTEBVBA offers a variety of educational activities around the transradial approach, including hands-on training and live cases.

Page 2: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

Product Benefits:Access in any anatomy• Theonlysheathintroduceravailablewitha0.014”

polymer-coated wire for easier navigation in challenging cases

• Alsoavailablewithabaremetal0.018”springwire

Smooth insertion and removal while maintaining stability • Lubriciouscoatingenablessmoothinsertionwhile

maintaining stability during the procedure

Patient comfort and ease of use• Seamlesstaperallowseasyinsertionandremoval

for patient comfort• Uniquesnap-fitdilatorpromotesgentleinsertion

and removal of dilator

Atraumatic tapered tip

Smooth transition from dilator to

sheath

IV cannula

Snap-fit dilator

Cordis Radial Solutions

Sheath Introducers

Cordis RADIALSOURCE® Access KitFor an easy and secure transradial access

Allows Seldinger Technique (dual wall puncture permitting a “hands free”approach), facilitating training of new radial operators.*

Seldinger technique was associated with shorter time to gaining access and higher success rates on first attempt, compared with modified Seldinger technique (single wall puncture). The incidence of access site bleeding complications, as well as radial artery occlusion (RAO), are comparable between Seldinger and modified Seldinger techniques.*

*Pancholy et al. CCI 80:288–291 (2012)

Page 3: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

Shea

th In

trod

uc

erSd

Iag

no

StIc W

IreSd

Iag

no

StIc c

ath

eterSg

uId

Ing

ca

theterS

Sha

peS

cordis AVANTI®+ transradial cSI Kit

Product Availability:

French Size 4F, 5F, 6F

Length (cm) 6.5, 10, 20

Mini Guidewire 0.014" polymer-coated

0.018" spring (bare metal) wire

Needle Type 20-gauge IV cannula for double wall puncture

Needle Length 1.2" (30 mm)

cordis RadialSouRce® access Kit

Product Availability:

French Size 4F, 5F, 6F, 7F

Length (cm) 11, 23

Mini Guidewire 0.021" spring (bare metal) wire

Needle Type 21-gauge bare needle for single wall puncture

Needle Length 1.5" (38 mm)

The well-proven Cordis AVANTI®+ Sheath also available for transradial procedures

Page 4: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

cordis Tempo® AquAhydrophilic-coated diagnostic catheter for navigating the most challenging cases with lubricity and control

product Benefits:Precise torque control and kink resistance

• Braidedconstructionallows1:1torquecontrolandenhanced pushability without compromising kink resistance

High flow rate with smooth contrast flow

• TRUELUMEN™ technology provides the same larger inner lumen diameter from hub to tip

– eliminating contrast jetting

– facilitating higher flow rates

Excellent visibility

• Radiopaquetipimprovesvisibilitytohelpreducetheriskofvasculardamage

Cordis TEMPO® AQUA Catheter providesLubricity

• a durable hydrophilic coating in the distal shaft provides easy advancement into the vascular and subintimal space

• coating is bonded to catheter for continued lubricity during entire procedure

Control

• proximal segment is uncoated for secure handling

• Braidingallows1:1torquecontrol

cordis Radial SolutionS

Diagnostic Catheters

The gold standard: market leader for over 40 yearsAn optimal intervention starts with an accurate coronary angiogram

Thebroadest*offeringofshapes,sizes,andmaterialsoptimizedfortorquecontrol, kink resistance, and visualization

TRUE

LUM

EN®

Technology

Every3 seconds*a Cordis catheteris used globally

* Cordis Data on File, 2011

*Datafrommajorcompetitor’sinformation,2012

Page 5: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

dIa

gn

oStIc

ca

theterS

dIa

gn

oStIc

ca

theterS

gu

IdIn

g c

ath

eterSSh

apeS

choose the brand that matches your preferences

INFINITI®

CatheterSUPERTORQUE® Plus

TEMPO®

AQUA

Material

French Size

Max Pressure

Body ID

Body OD

Radiopaque Tip

Nylon

4F 5F 6F 5.2F 6F 5F

0.042" 0.047" 0.057" 0.044" 0.051" 0.048"

0.054" 0.067" 0.079" 0.068" 0.079" 0.067"

YES YES YES YES YES YES

1200 PSI 1200 PSI 1200 PSI 1200 PSI 1200 PSI 1200 PSI

PolyurethaneNylon with

Hydrophilic Coating

Judkins Right (JR)First choice to engage the rca ostia. conventional femoral Jr4 is usually satisfactory for the right radial approach as well.

Amplatz Left (AL)TheAmplatzleft1and2givesadequatealignmentinthemajority of right coronaries irrespective of the take off. however, it is sometimes difficult to handle and may travel deep into the coronary.

Right Coronary Artery

Amplatz Left (AL1)amplatz left catheters are “tricky” for ostial access. they run the risk of dissection of the ostium. however, soft tip catheters have dramatically reduced this risk.

Judkins Left (JL)FirstchoicetoengagetheLCAostia.Ingeneral,requiressmallercatheters(i.e.JL3.5)comparedwiththoseusedforfemoral or left radial approaches.

Left Coronary Artery

Page 6: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

cordis Radial SolutionS

Diagnostic Catheters

Barbeau

coronary angioplasty via radial access of the left and right coronary arteries.

•Primarycurveof135degreesaddedtoanMPAcatheter(MultipurposeA).

•Canbeusedforbothrightandleftostiumcannulation.•IftheleftcoronaryarteryisdifficulttocannulateuseaJL3.5.

available in a wide variety of shapes, including transradial-specific

Brachial left (BL) (Tilon)

coronary angioplasty via radial access of the left and right coronary arteries.

•Allowseffectivecannulationandangiographyoftheleftcoronary artery.

•Allowseasyandeffectivecannulationandangiographyoftheright coronary artery when the ostium is at the same level as the left ostium.

Leman

coronary angiography via radial access of the left and right coronary arteries.

Radial Bi-Lateral (RBL)

the most popular radial dedicated shape designed for left and right coronary arteries cannulation.

AfterengagingtheLCAandperformingthecoronaryangiography,pullbacktheRBLcatheterfromtheLCAostiaslowlyrotateclockwiseandpushuntilthetipenterstherightsinusofValsalvaandthentheRCA.coronary angiography of the rca can then be performed.

CordisofferaseriesofcatheterchoicestocanulateboththeLCAandRCA.Thesecathetersdon’tneedto be exchanged. reduced catheter exchanges and movements mean less radial artery spasm, radiation exposure and procedure time.*

AfterengagingtheLCAandperformingthecoronary angiography. to catheterize the right coronary artery, the operator first needs to alternate clockwise and counterclockwise rotation to reach the right sinus and simultaneously advance the catheter distally into the cusp.

*Kim et al.IntJCardiovascImaging.2006Jun-Aug;22(3-4):295-303

Page 7: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

Still looking for the right shape? ask about the cordis u-shape It program to create catheters that fit your specific needs.

Radial Brachial Multipurpose (RBMP)

AvariationoftheRBLcatheter.TheRBMPalsoallowscoronarycatheterisation and angioplasty via radial access of the left and rightcoronaryarteries.Moresuitableforinferiorandnormaltake-offs.

IM MOD (Barbeau) Curve angiography via right radial approach of left and right internal mammary arteries.

3D LIMA 90 Curveangiography via right radial approach of left and right internal mammary arteries.

IM MOD (Bartorelli Cozzi)coronary angiography for selective access to the right and left internal mammary artery via right or left radial access.

IMwithadesignmoreparticularlymarkedbyaprimarycurvatureof180°forbettercoaxialalignmentintheostium of the left internal mammary artery and a secondary curvatureof90°forsupportinthesub-clavianartery.

Page 8: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

Greater Turn-for-Turn ResponsivenessaQuatracK®Guidewirehasbettertorquecontrolthan the terumo glidewire® guidewire.

Torque devicepackaged with every

AQUATRACK®

Guidewire

cordis Radial SolutionS

prepared for seamless diagnostic procedures

product Benefits:Easy navigation• Increasedturn-for-turnresponsiveness

leading to multivessel selection and lesion crossability

Greater visibility • Excellentradiopacitycanhelppromote

faster and more accurate procedures

Lasting lubricity• Accesswithexcellentguideanddevice

support, with a smooth ride from start to finish

Diagnostic Guidewires

cordis AquATRACk®

hydrophilic nitinol diagnostic guidewire – designed to facilitate access in the most tortuous anatomies

1 cordis data on File

Page 9: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

A Smooth Ride from Start to FinishaQuatracK® guidewire provides lasting lubricity for excellent guide and device support.

Greater VisibilitySeeing your every move can help promote faster and more accurate procedures.

Product Availability:

Diameter (inches) 0.035"

Length (cm) 150, 180, 260

Stiffness regular, Stiff

Tip angled, Straight

dIa

gn

oStIc

gu

IdeW

IreS

1 cordis data on File

Page 10: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

Product Availability:

Available in Fixed Core, Movable Core, and PTFE Coated Movable Core

Diameter (inches)

Length (cm)

Flexible Tip Length (cm)

Tip

0.018" 0.025" 0.030" 0.032" 0.035" 0.038"

260 150 260

150 150 260

150 175 260

150 175 260

7 7 7 7 7 3, 5, 7

J-tip J-tip Straight

J-tip J-tip Straight

J-tip Straight

J-tip Straight

cordis emeRAlD™

pre-coated ptFe diagnostic guidewire performance, endurance, and safety for any procedure

product Benefits:Easy navigation• Versatilityoftipshapesandflexibilities• Enhancedmaneuverability• Fingerstraightenability

Built-in safety• Solidtensilestrengthminimizesthelikelihood

of stretching or fracturing• Safetyribbonisweldedtobothendsofthewire

to help it remain intact in the event of a fracture or stretching

cordis Radial SolutionS

Diagnostic Guidewires

Page 11: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

cordis Radial SolutionS

Guiding Catheters

product Benefits:Back-up support and torque control

patented hybrid braiding and the multisegment designprovides:

• Optimalback-upsupportthathelpsyoucrossdifficult lesions

• Excellenttorqueresponseforcontrol

Shape retention

• Designedtomaintainshapeandremainengagedduringlengthy and challenging procedures

Easy delivery of devices

• PTFELiningandpatentedTRUELUMEN™Technologyprovideconsistently lubricious lumen from hub to tip for easy delivery of devices

Excellent visibility

• Ultrasoft,highlyradiopaquetippromotessafeandatraumaticengagement

cordis VISTA BRITe TIp®

designed for support and performance

giving you the confidence and support even in the most challenging cases

Long VISTA BRITE TIP® guiding catheter enables safe deep seating and provides additional support and stability for less traumatic active engagement.

Extra-Back up shapes available

gu

IdIn

g c

ath

eterS

Page 12: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

choose the guide catheter that works for you

VISTA BRITE TIP® Long VISTA BRITE TIP®

French Size

Guide OD

Guide ID

Braiding

Liner

Tip Length

5F (1.65 mm) 6F (2.10 mm) 7F (2.30 mm) 5F (1.65 mm) 6F (2.11 mm)

5F 6F 7F 5F 6F

Stainless Steel

PTFE

0.1"(2.5 mm) 0.1"(2.5 mm) 0.1"(2.5 mm) 0.62"(16 mm) 0.62"(16 mm)

0.056"(1.4 mm) 0.070"(1.8 mm) 0.078"(2.0 mm) 0.056"(1.4 mm) 0.070"(1.8 mm)

XB 2.5In general, engagement of the left coronary arteryrequiressmallercatheters(i.e.aJL3.5comparedwithaJL4)comparedwiththoseused for femoral or left radial approaches. XB-2.5isasmallercurveofthebestsellingXBfamily.SuitableforaortasinwhichJL-3.0would be needed radialy.

Judkins Fajadet Right (JFR)

a modification of the Judkins catheters especially developed for giving extra back-up during transradial procedures.

Judkins Fajadet Left (JFL)

available in a wide variety of shapes, including transradial-specific

Extra Back-up in TRA Interventions

cordis Radial SolutionS

Guiding Catheters

Page 13: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

Still looking for the right shape? ask about the cordis u-shape It program to create catheters that fit your specific needs.

CordisofferaseriesofcatheterchoicestocanulateboththeLCAandRCA.

Radial Bi-Lateral / Multipurpose

Brachial left (BL) (Tilon)

coronary catheterisation via right radial access of the left and right coronary arteries.

•Allowseffectivecannulationoftheleftcoronaryartery

Barbeau

coronary catheterisation via right radial access of the left and right coronary arteries.

•Primarycurveof135degreesaddedtoanMPAcatheter(MultipurposeA)

•Canbeusedfortherightandleftostiumcannulation•Curvatureverysuitablefortherightcoronaryartery•IftheleftcoronaryarteryisdifficulttocannulateuseaXB

catheter

Radial Brachial (RB) – Kimny Technique

DesignedtoperformtherighttransradialKimnyTechnique,canbe used to engage both the left and right coronary arteries. the shape is designed with three angles that allow contralateral wall support and tip engagement.

Radial Bi-Lateral (RBL)

the guiding catheter version of the popular diagnostic catheter, designed for cannulation of both the left and right coronary arteries.

Page 14: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

Create the tools you need for tailored performance

ModificationsareavailablethroughtheCordisu-shape It program

Beyondthewidevarietyofpopularshapesandsizesthatareavailablefortransradial,Cordis offersmodificationstostandardproductsforyourspecificneeds.Modificationscanbemadetothe shape, length and side holes of catheters. please contact your cordis sales representative for more information.

cordis Radial SolutionS

Services & education

Page 15: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

Product Benefits:Access in any anatomy• Theonlysheathintroduceravailablewitha0.014”polymer-coatedwireforeasiernavigationinchallengingcases

• Alsoavailablewithabaremetal0.018”springwire

Smooth insertion and removal while maintaining stability • Lubriciouscoatingenablessmoothinsertionwhilemaintainingstabilityduringtheprocedure

Patient comfort and ease of use• Seamlesstaperallowseasyinsertionandremovalforpatientcomfort

• Uniquesnap-fitdilatorpromotesgentleinsertionandremovalofdilator

Atraumatictaperedtip

Smoothtransitionfromdilatorto

sheath

IVcannula

Snap-fitdilator

CordisRadial Solutions

Sheath Introducers

Cordis RadIalSouRce®AccessKitForaneasyandsecuretransradialaccess

AllowsSeldingerTechnique(dualwallpuncturepermittinga“handsfree”approach),facilitatingtrainingofnewradialoperators.*

Seldingertechniquewasassociatedwithshortertimetogainingaccessandhighersuccessratesonfirstattempt,comparedwithmodifiedSeldingertechnique(singlewallpuncture).Theincidenceofaccesssitebleedingcomplications,aswellasradialarteryocclusion(RAO),arecomparablebetweenSeldingerandmodifiedSeldingertechniques.*

*Pancholyetal.CCI80:288–291(2012)

coRdIS® caRdIac & VaSculaR INSTITuTeBVBa

Keepthewheelofknowledgeturning

ThemissionoftheCORDIS®CARDIAC&VASCULARINSTITUTEBVBAistoprovideglobalhealthcareprofessionalsthehighestqualitytherapyeducationandmedicaldeviceskillstraining.Cordisiscommittedtothedevelopmentofeducationalopportunitiesfornewprocedures,techniques,andtechnology.Foradvancesineducation,clinicalnetworking,andthesharingofresourcestoexpandthebreadthanddepthofknowledgeofglobalhealthcareproviders,Cordisoffersanarrayofservices.

Cordis Offers:

•GlobalEducationExchangeProgram

•OnlineOfferings

•Simulation

•LiveCourses

Registerforwww.ccvi-online.com /eMeaanddiscoveranetworkofexpertisededicatedtoadvancingcardiacandvascularcare.

Page 16: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

Important Information:Prior to use, refer to the “instructions for use” supplied with these devices for indications, contraindications, side effects, suggested procedure, warnings and precautions. As part of the Cordis policy of continuous product development we reserve the right to change product specifications without prior notification. Tel:+32 2 746 30 00 Fax:+32 2 746 34 05© Cordis Europe, a division of Johnson & Johnson Medical N.V. - November 2012 - 2E-800-1988-3

Cordis Radial SolutionsIntegrated solutions for transradial care

CORDIS® CARDIAC & VASCULAR INSTITUTEBVBA

Keep the wheel of knowledge turning

The mission of the CORDIS® CARDIAC & VASCULAR INSTITUTE

BVBA is to provide global healthcare

professionals the highest quality therapy education and medical device skills training. Cordis is committed to the development of educational opportunities for new procedures, techniques, and technology. For advances in education, clinical networking, and the sharing of resources to expand the breadth and depth of knowledge of global healthcare providers, Cordis offers an array of services.

Cordis Offers:

• Global Education Exchange Program

• Online Offerings

• Simulation

• Live Courses

Register for www.ccvi-online.com /EMEA and discover a network of expertise dedicated to advancing cardiac and vascular care.

Enhanced radial performance with full-service support

Sheath IntroducersA smooth first step to transradial procedures, with atraumatic access and excellent performance.

Diagnostic WiresAvailable in multiple cores, coatings, tips, diameters, and lengths to help ensure performance and safety.

Diagnostic CathetersBest-in-class catheters available in the widest selection of shapes — now including new transradial- specific shapes.

Guiding CathetersBalancing support, flexibility, and control for optimal access and backup with one of the broadest ranges of shapes and sizes available — now with new transradial-specific shapes.

ServicesCordis U-shape It Program allows you to modify our catheters to meet your specific needs.

Professional EducationCORDIS® CARDIAC & VASCULAR INSTITUTEBVBA offers a variety of educational activities around the transradial approach, including hands-on training and live cases.

Page 17: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

Cordis RadialSouRce™

Sheath IntroduCerS

Catalogue Number French Size (F) Length, cm Wire Type

505-604P 4 6.5 Polymer Coated

505-604S 4 6.5 Spring

505-614P 4 10 Polymer Coated

505-614S 4 10 Spring

505-624P 4 20 Polymer Coated

505-624S 4 20 Spring

505-605P 5 6.5 Polymer Coated

505-605S 5 6.5 Spring

505-615P 5 10 Polymer Coated

505-615S 5 10 Spring

505-625P 5 20 Polymer Coated

505-625S 5 20 Spring

505-606P 6 6.5 Polymer Coated

505-606S 6 6.5 Spring

505-616P 6 10 Polymer Coated

505-616S 6 10 Spring

505-626P 6 20 Polymer Coated

505-626S 6 20 Spring

Cordis avanti®+

Catalogue Number French Size (F) Length (cm) Guidewire Acceptance (“)

504-614Z 4F 11 .021

504-624Z 4F 23 .021 70cm

504-615Z 5F 11 .021

504-625Z 5F 23 .021 70cm

504-616Z 6F 11 .021

504-626Z 6F 23 .021 70cm

504-617Z 7F 11 .021

transradial Sheath Introducer Kit with Mini-guidewire

• With mini-guidewire, vessel dilator and 21G needle• With mini-guidewire, (spring wire or polymer coated wire) vessel dilator and 20G IV cannula

transradial access Kit

Catalogue

Number

Units per package Cannula OD Guidewire Acceptance (“)

Length (cm)

12-004924 10 21G .021 3.8

Angiographic needle for transradial puncture

Page 18: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

Cordis emeRald™

dIagnoStIC guIdeWIreS

Cordis aquatRack®

Catalogue Number Length, cm Stiffness Taper Tip

C3515-RSS 150 Regular Short Straight

C3515-RSA 150 Regular Short Angled

C3515-SSA 150 Stiff Short Angled

C3518-RSS 180 Regular Short Angled

C3518-RSA 180 Regular Short Angled

C3518-SSA 180 Stiff Short Angled

C3526-SSS 260 Stiff Short Straight

C3526-RSA 260 Regular Short Angled

C3526-SSA 260 Stiff Short Angled

Wire Diameter 0.035”

Coating Polymer hydrophilic jacket

Packaging 5/Box

hydrophilic guidewire

guidewire

Fixed-Core PTFE Coated Wire

Catalogue Number

Diameter, (“)

Length, cm

J radius, mm

Flexible tip Length, cm

Remarks

J-Tip Wires

502-524 0.025 150 3 7 Standard Tip

502-536 0.025 150 1.5 7 Standard Tip

502-522 0.030 150 3 7 Standard Tip Heavy-Duty Corewire

502-526 0.032 150 3 7 Standard Tip

502-534 0.035 175 1.5 7 Standard Tip Heavy-Duty Corewire

502-521 0.035 150 3 7 Standard Tip

502-589 0.035 150 6 7 Standard Tip

502-535 0.035 150 1.5 7 Standard Tip

502-585 0.035 175 3 7 Standard Tip

502-520 0.038 150 3 7 Standard Tip

502-588 0.038 150 6 7 Standard Tip

502-584 0.038 175 3 7 Standard Tip

Straight-Tip Wires

502-549 0.025 150 - 7 Standard Tip

502-548 0.032 150 - 7 Standard Tip

502-542 0.035 150 - 7 Standard Tip

502-541 0.038 150 - 7 Standard Tip

J-Tip Wires

502-571 0.035 150 3 7 Standard Tip

502-570 0.038 150 3 3 Extra Firm Tip

Amplatz Type, J-Tip

502-570A 0.038 150 3 3 Extra Firm Tip

Amplatz Type, Straight Tip

502-581A 0.035 150 - 7 Standard Tip

Straight-Tip Wires

502-581 0.035 150 1 7 Standard Tip

Exchange Straight-Tip Wires

502-554 0.032 260 - 7 Standard Tip

502-558 0.035 260 - 7 Standard Tip

502-555 0.035 260 - 7 Standard Tip

502-553 0.038 260 - 7 Standard Tip

Exchange J-Tip Wires

502-456 0.018 260 3 7 Standard Tip

502-452 0.025 260 3 7 Standard Tip

502-455 0.035 260 3 7 Standard Tip

502-453 0.038 260 3 5 Firm Tip

502-453 0.038 260 3 7 Standard Tip

Double Ended Wires (Straight/J-Tip)

502-563 0.035 150 2 7 Standard Tip

Fixed-Core PTFE Coated Exchange Wires

Page 19: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

dIagnoStIC CatheterS

Transradial Shapes

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.** TEMPO® AQUA® Hydrophilic-Coated Diagnostic Catheter: • 1 unit per package. • Hydrophilic-coated Diagnostic Catheter for navigating the most challenging pathways with lubricity and control. • Braided Nylon body, Neon TIP (tungsten filled radiopaque tip), Lipiodol resistant hub, Micro-catheter compatibility, Hydrophilically coated distal shaft. † 5 units per package

Shape

Radial Bi-lateRal technique

name picture Side holelength (cm)

4F 5F 5F 5.2F 6F 6F

BARBEAU 2 100 SRd5505 534-578t SRd5897

BARBEAU 2 125 SRd6000*

BL (Tilon) 100 SRd5394 SRd5602† SRd5892

Leman 100 SRd7050

RBL 4.0 100 SRd7045 SRd7063 SRd7064

RBL 4.0 2 100 SRd7057 SRd7044 SRd7059 SRd7055 SRd7048

RBL 4.0 110 SRd7027

RBL 4.5 100 SRd7074† SRd7070 SRd7071 SRd7073

RBL 5.0 2 100 SRd7058 SRd7046 SRd7060 SRd7056 SRd7049

RBL 5.0 100 SRd7047 SRd7065 SRd7066

RBL 5.0 110 SRd7026

RBPM 100 SRd6724 SRd5757

QUICk CARE INFINITI®

SUPERTORQUE® Plus

SUPERTORQUE® Plus INFINITI®INFINITI®

TEMPO® AQUA®**

• For percutaneous entry and guidance of angiographic catheters• Units per Package: 5

Page 20: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

Diagnostic catheters

Transradial Shapes

Shape

Shape

SONeS TeChNIQUe

Name picture Side holeLength (cm)

5F 5F 5.2F 6F 6F

SON I 2 80 534-530T

SON I 100 SRD7012 534-562T 533-630 534-635T

SON I.5 100 534-564T

SON II 80 533-531

SON II 2 80 534-531T

SON II 100 533-631 534-637T

SON III 100 533-632

CaSTILLO TeChNIQUe

Name picture Side holeLength (cm)

5F 5F 5.2F 6F 6F

CAS I 100 533-584 533-684

CAS II 80 533-682

CAS II 100 533-585 533-685

CAS III 100 533-686

INFINITI®

INFINITI®

SuperTOrque® plus

SuperTOrque® plus

SuperTOrque® plus

SuperTOrque® plus

INFINITI®

INFINITI®

TempO® AquA®**

TempO® AquA®**

* please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.** TempO® AquA® Hydrophilic-Coated Diagnostic Catheter: •1unitperpackage. •Hydrophilic-coatedDiagnosticCatheterfornavigatingthemostchallengingpathwayswithlubricityandcontrol. •BraidedNylonbody,NeonTIP(tungstenfilledradiopaquetip),Lipiodolresistanthub,Micro-cathetercompatibility,Hydrophilicallycoateddistalshaft.‡3unitsperpackage

Shape

LeFT INTeRNaL MaMMaRY VIa RIGhT OR LeFT RaDIaL appROaCh

Name picture Side holeLength (cm)

4F 5F 5.2F 6F 6F

3DLIMA90‡ 100 SRD6732 SRD6305

Im mOD (Barbeau)

100 SRD6837

Im mOD (Bartorelli-Cozzi)

100 SRD6666* SRD5392

quICk CAre INFINITI® INFINITI®

SuperTOrque® plus

SuperTOrque® plus INFINITI®

Page 21: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

dIagnoStIC CatheterS

Transradial Shapes

Shape

teMpO® aqua® hYdROphilic

name picture Side hole length (cm)5F 5F

RBL 4.0 100 SRd7045

RBL 4.5 100 SRd7074

RBL 5.0 100 SRd7047

SON I 100 SRd7012

BL (Tilon) 100 SRd5602

JL 3 100 SRd6994*

JL 3.5 100 SRd7061

JL 4 100 SRd7042

AL I 100 SRd7011

AL II 100 SRd7043

JR 4 100 SRd7009

IM 80 SRd6945

IM 100 SRd7010

INFINITI®TEMPO® AQUA®**

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.** TEMPO® AQUA® Hydrophilic-Coated Diagnostic Catheter: • 1 unit per package. • Hydrophilic-coated Diagnostic Catheter for navigating the most challenging pathways with lubricity and control. • Braided Nylon body, Neon TIP (tungsten filled radiopaque tip), Lipiodol resistant hub, Micro-catheter compatibility, Hydrophilically coated distal shaft.

Page 22: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

dIagnoStIC CatheterS

Shape

Shape

Left Coronary Techniques

JudKinS leFt

name picturelength (cm)

4F 5F 5F 5.2F 6F 6F

JL 3 100 SRd5436* SRd6994* SRd5157* SRd6979*

JL 3.5 100 538-418 SRd7061 534-518t 533-551 533-618 534-618t

JL 3.5 125 SRd2754* SR4990*

JL 4 100 538-420 SRd7042 534-520t 533-553 533-620 534-620t

JL 4 125 SRd5217* SRd6620* SR4690* SRd5918* 534-614t

JL 4.5 100 538-417 534-517t 533-527 533-627 534-617t

JL 4.5 125 SRd6018*

JL 5 100 538-422 534-522t 533-559 533-622 534-622t

JL 5 125 SRd6941* SR4778* SR5004* SRd5945* SRd5106*

aMplatZ leFt

name pictureSide hole

length (cm)

4F 5F 5F 5.2F 6F 6F

AL I 100 538-445 SRd7011 534-545t 533-540 533-645 534-645t

AL I 125 SRd5566* SR3734* SR3349* SRd5554*

AL I 12 125 SRd5065*

AL II 100 538-446 SRd7043 534-546t 533-542 533-646 534-646t

AL II 125 SRd6038* SR4982* SR3008* SR3708*

AL II 2 125 SR4784*

AL II 12 125 SRd5440*

AL III 100 538-447 534-547t 533-544 533-647 534-647t

AL III 125 SRd5286* SR3957* SR3709* SRd6636*

QUICk CARE INFINITI®

QUICk CARE INFINITI®

INFINITI®

INFINITI®

SUPERTORQUE® Plus

SUPERTORQUE® Plus

SUPERTORQUE® Plus

SUPERTORQUE® Plus

INFINITI®

INFINITI®

TEMPO® AQUA®**

TEMPO® AQUA®**

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.** TEMPO® AQUA® Hydrophilic-Coated Diagnostic Catheter: • 1 unit per package. • Hydrophilic-coated Diagnostic Catheter for navigating the most challenging pathways with lubricity and control. • Braided Nylon body, Neon TIP (tungsten filled radiopaque tip), Lipiodol resistant hub, Micro-catheter compatibility, Hydrophilically coated distal shaft.

Page 23: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

dIagnoStIC CatheterS

Shape

Shape

Right Coronary Techniques

JudKinS RiGht

name picturelength (cm)

4F 5F 5F 5.2F 6F 6F

JR 3.5 100 538-419 534-519t 533-550 533-619 534-619t

JR 3.5 125 SR2755* SRd6638*

JR 4 100 538-421 SRd7009 534-521t 533-552 533-621 534-621t

JR 4 125 SRd5216* SRd6604* 533-565 SR3757* 534-615t

JR 4 MOD 100 538-428 534-528t 533-528 533-628 534-628t

JR 5 100 538-423 534-523t 533-558 533-623 534-623t

JR 5 125 SR4777* SR5005* SR3471*

JR 6 100 538-425 534-525t 533-560 533-625 534-625t

JR 6 125 SR4780* SR2888* SR3465*

aMplatZ RiGht

name picture Side holelength (cm)

4F 5F 5.2F 6F 6F

AR MOD 100 538-448 534-548t 533-554 533-648 534-648t

AR MOD 125 SRd2985*

AR I MOD 100 538-441 534-541t 533-641 534-641t

AR I MOD 125 SRd4884*

AR II MOD 100 538-443 534-543t 533-643 534-643t

AR II MOD 125 SRd5036* SRd6662*

QUICk CARE INFINITI®

QUICk CARE INFINITI®

INFINITI®

INFINITI®

SUPERTORQUE® Plus

SUPERTORQUE® Plus

SUPERTORQUE® Plus

SUPERTORQUE® Plus

INFINITI®

INFINITI®

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.** TEMPO® AQUA® Hydrophilic-Coated Diagnostic Catheter: • 1 unit per package. • Hydrophilic-coated Diagnostic Catheter for navigating the most challenging pathways with lubricity and control. • Braided Nylon body, Neon TIP (tungsten filled radiopaque tip), Lipiodol resistant hub, Micro-catheter compatibility, Hydrophilically coated distal shaft.

TEMPO® AQUA®**

Page 24: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

dIagnoStIC CatheterS

Shape

Multipurpose Technique

MultipuRpOSe

name picture Side holelength (cm)

4F 5F 5.2F 6F 6F

MPA 1 80 533-579 533-633

MPA 1 100 533-578 533-640

MPA 1 125 SR2516* 533-667

MPA 2 SH 2 65 533-562

MPA 2 SH 2 80 533-532 533-629

MPA 2 SH 2 100 534-542t 533-582 533-642 534-642t

MPA 2 SH 2 125 534-544t 533-587 533-644 534-644t

MPB 2 2 100 534-539t 533-649 534-649t

MPB 3 6 100 533-634

Shape

cOROnaRY BYpaSS techniqueS

name picturelength (cm)

4F 5F 5F 5.2F 6F 6F

LCB 100 538-472 534-572t 533-572 533-672 534-672t

LCB 125 SRd6707* SRd6996*

RCB 100 538-470 534-570t 533-570 533-670 534-670t

RCB 125 SRd6997*

IM 80 SRd6945

IM 100 538-460 SRd7010 534-560t 533-580 533-660 534-660t

IM 125 SRd6708* SRd6998*

Bypass

QUICk CARE INFINITI®

QUICk CARE INFINITI®

INFINITI®

INFINITI®

SUPERTORQUE® Plus

SUPERTORQUE® Plus

SUPERTORQUE® Plus

SUPERTORQUE® Plus

INFINITI®

INFINITI®

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.** TEMPO® AQUA® Hydrophilic-Coated Diagnostic Catheter: • 1 unit per package. • Hydrophilic-coated Diagnostic Catheter for navigating the most challenging pathways with lubricity and control. • Braided Nylon body, Neon TIP (tungsten filled radiopaque tip), Lipiodol resistant hub, Micro-catheter compatibility, Hydrophilically coated distal shaft.

TEMPO® AQUA®**

Page 25: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

dIagnoStIC CatheterS

Ventricular & Cardiac Catheters

Shape

Shape

VentRiculaR StRaiGht piGtail

name pictureSide hole

length (cm)

4F 5F 5F 5.2F 6F 6F

PIG 4SH 4 110 533-650F

PIG 5SH 5 110 538-451V

PIG 6SH 6 110 538-450S*** 534-550S 533-533 533-650S 534-650S

PIG 6SH 6 125 SRd5406* SRd5927* SRd6064* SR3279* SRd5085*

PIG 8SH 8 110 538-450e*** 534-550e 533-650e 534-650e

PIG 12SH 12 110

PIG 110 SRd6722*

VentRiculaR anGled piGtail: Van taSSel technique

name picture Side holelength (cm)

4F 5F 5.2F 6F 6F

PIG 145° MOD 5SH

5 110 538-457V

PIG 145° 6SH 6 110 534-552S 533-534a 533-652S 534-652S

PIG 145° 6SH 6 125 SRd5284* SR4885* SR3054*

PIG 145° MOD 6SH

6 110 538-453S*** 534-553S 533-537S 533-653S

PIG 155° MOD 5SH

5 110 538-459V 534-555S

PIG 155° 6SH 6 110 534-554S 533-533a 533-654S 534-654S

PIG 155° 6SH 6 125 SRd5117* SR3833* SRd5109*

PIG 155° MOD 6SH

6 110 538-455S*** 533-655S

QUICk CARE INFINITI® INFINITI®

SUPERTORQUE® Plus

SUPERTORQUE® Plus INFINITI®

QUICk CARE INFINITI® INFINITI®

SUPERTORQUE® Plus

SUPERTORQUE® Plus INFINITI®

TEMPO® AQUA®**

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.** TEMPO® AQUA® Hydrophilic-Coated Diagnostic Catheter: • 1 unit per package. • Hydrophilic-coated Diagnostic Catheter for navigating the most challenging pathways with lubricity and control. • Braided Nylon body, Neon TIP (tungsten filled radiopaque tip), Lipiodol resistant hub, Micro-catheter compatibility, Hydrophilically coated distal shaft. *** Micro Loop

Page 26: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

dIagnoStIC CatheterS

Long Catheters

Shape

long catheters

name picture Side holelength (cm)

4F 5F 5.2F 6F 6F

AL 1 125 SRd5566* SR3734* SR3349* SRd5554*

AL 1 12 125 SRd5065*

AL 2 125 SRd6038* SR4982* SR3008* SR3708*

AL 2 12 125 SRd5440*

AL 2 2 125 SR4784*

AL 3 125 SRd5286* SR3957* SR3709* SRd6636*

AR MOD 125 SR2985*

AR I MOD 125 SRd6884*

AR II MOD 125 SRd5036* SRd6662*

BARBEAU 2 125 SRd6000*

IM 125 SRd6708* SRd6998*

JL 3.5 125 SR2754* SR4990*

JL 4 125 SRd5217* SRd6620* SR4690* SRd5918* 534-614t

JL 4.5 125 SRd6018*

JL 5 125 SRd6941* SR4778* SR5004* SRd5945* SRd5106*

JR 3.5 125 SR2755* SRd6638*

JR 4 125 SRd5216* SRd6604* 533-565 SR3757* 534-615t

JR 5 125 SR4777* SR5005* SR3471*

JR 6 125 SR2888* SR3465*

LCB 125 SRd6707* SRd6996*

MPA 1 125 SR2516* 533-667

MPA 2 125 534-544t 533-587 533-644 534-644t

RCB 125 SRd6997*

QUICk CARE INFINITI® INFINITI®

SUPERTORQUE® Plus

SUPERTORQUE® Plus INFINITI®

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.

Page 27: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

JudKinS leFt

name picture Observation5F 6F 7F 8F

JL 3 670-000-00 778-000-00 588-812

JL 3 SH 2 side holes 778-001-00

JL 3.5 670-002-00 778-002-00 588-851

JL 3.5 LBT Long VISTA BRITE TIP® 556-002-0l

JL 3.5 ST short tip 670-012-00 778-012-00

JL 3.5 SH 2 side holes 670-003-00 778-003-00 588-832

JL 4 670-004-00 778-004-00 588-823

JL 4 90 cm 670-004-90

JL 4 LBT Long VISTA BRITE TIP® 556-004-0l 670-004-0l

JL 4 ST short tip 670-014-00 778-014-00

JL 4 SH 2 side holes 670-005-00 778-005-00 588-834

JL 4 ST SH short tip, 2 side holes 778-015-00

JL 4 125 cm SM7435* SM6987*

JL 4 SH 125 cm, 2 side holes SM7128*

JL 4.5 670-006-00 778-006-00 588-852

JL 4.5 LBT Long VISTA BRITE TIP® SM7329

JL 4.5 ST short tip 670-016-00

JL 4.5 SH 2 side holes 778-007-00 588-810

JL 5 670-008-00 778-008-00 588-853

JL 5 LBT Long VISTA BRITE TIP® 556-008-0l

JL 5 SH 2 side holes 778-009-00 588-800

JL 5 125 cm SM7361* SM6731*

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.

Shape

JudKinS cuRVed leFt

JCL 3.5 670-026-00

JCL 3.5 SH 2 side holes 670-027-00

JCL 4 670-028-00

guIdIng CatheterS

Left Coronary Judkins Technique

Page 28: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

guIdIng CatheterS

Left Coronary Extra Back-Up Shapes

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.

eXtRa BacK-up

name picture Observation5F 6F 7F 8F

XB 2.5 SM7465

XB 3 670-052-00 778-052-00 588-829

XB 3 125 cm SM7395*

XB 3 LBT Long VISTA BRITE TIP® SM7328

XB 3 SH 2 side holes 670-053-00 778-053-00 588-875

XB 3.5 670-054-00 778-054-00 588-882

XB 3.5 90 cm 670-054-90

XB 3.5 LBT Long VISTA BRITE TIP® 556-054-0l 670-054-0l

XB 3.5 SH 2 side holes 670-055-00 778-055-00 588-885

XB 3.5 LBT Long VISTA BRITE TIP®, 120 cm SM7400*

XB 3.5 125 cm SM7437* SM6991*

XB 4 670-056-00 778-056-00 588-894

XB 4 125 cm SM7363*

XB 4 LBT Long VISTA BRITE TIP® 556-056-0l

XB 4 SH 2 side holes 670-057-00 778-057-00 588-896

XB 4.5 670-058-00 778-058-00

XB 4.5 SH 2 side holes 670-059-00 778-059-00

XBC 3 670-070-00

XBC 3 SH 2 side holes 670-071-00

XBC 3.5 670-072-00

XBC 3.5 LBT Long VISTA BRITE TIP® SM7466

XBC 3.5 SH 2 side holes 670-073-00

XBC 4 670-074-00

XBC 4.5 SH 2 side holes 670-077-00

XBLAD 3 670-066-00

XBLAD 3 SH 2 side holes 670-067-00

XBLAD 3.5 670-060-00 778-060-00 588-8100

Shape

Page 29: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

guIdIng CatheterS

XBLAD 3.5 LBTLong VISTA BRITE TIP® 556-060-0l

XBLAD 3.5 SH 2 side holes 670-061-00 778-061-00 588-8103

XBLAD 4

670-062-00 778-062-00 588-8101

XBLAD 4 SH 2 side holes 670-063-00 778-063-00

XBLAD 4.5 670-064-00

eXtRa BacK-up

name picture Observation5F 6F 7F 8F

Shape

Left Coronary Extra Back-Up Shapes

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.

Left Coronary Amplatz Technique

Shape

aMplatZ leFt

name picture Observation5F 6F 7F 8F

AL .75 670-034-00 778-034-00 588-890

AL .75 SH 2 side holes 670-035-00

AL 1 670-036-00 778-036-00 588-843

AL 1 LBT Long VISTA BRITE TIP® SM7331 SM7389*

AL 1 ST short tip 670-044-00 778-044-00 588-870

AL 1 SH 2 side holes 670-037-00 778-037-00 588-847

AL 1 ST SH short tip, 2 side holes 778-045-00

AL 1 125 cm SM7438* SM7115*

AL 1.5 670-038-00 778-038-00

AL 1.5 SH 2 side holes 778-039-00 588-878

AL 2 670-040-00 778-040-00 588-844

AL 2 90 cm 588-844t

AL 2 125 cm SM7279*

Page 30: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

guIdIng CatheterS

AL 2 LBT Long VISTA BRITE TIP® 556-040-0l 670-040-0l

AL 2 ST short tip 778-048-00

AL 2 SH 2 side holes 670-041-00 778-041-00 588-848

AL 3 670-042-00 778-042-00 588-849

AL 3 125 cm SM6988*

AL 3 LBT Long VISTA BRITE TIP® SM7332

AL 3 SH 2 side holes 778-043-00 588-891

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.

Left Coronary Amplatz Technique

aMplatZ leFt

name picture Observation5F 6F 7F 8F

Shape

Right Coronary Judkins Technique

JudKinS RiGht

name picture Observation5F 6F 7F 8F

JR 3.5 670-080-00 778-080-00 588-855

JR 3.5 125 cm SM7371*

JR 3.5 LBT Long VISTA BRITE TIP® 556-080-0l SM7390*

JR 3.5 SH 2 side holes 670-081-00 778-081-00 588-828

JR 4 670-082-00 778-082-00 588-830

JR 4 90 cm 670-082-90

JR 4 LBT Long VISTA BRITE TIP® 556-082-0l 670-082-0l

JR 4 LBT 110 cm SM7426*

JR 4 ST short tip 670-090-00 778-090-00

JR 4 SH 2 side holes 670-083-00 778-083-00 588-831

JR 4 125 cm SM7436*

JR 4 SH 125 cm, 2 side holes SM7444*

JR 4.5 ST short tip 778-092-00

Shape

Page 31: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

guIdIng CatheterS

Right Coronary Extra Back-Up Shapes

Right Coronary Amplatz Technique

WilliaMS technique

name picture Observation5F 6F 7F 8F

3DRC 670-130-00

3DRC LBT Long VISTA BRITE TIP® SM7599*

3DRC SH 2 side holes 670-131-00

aMplatZ RiGht

name picture Observation5F 6F 7F 8F

AR 1 670-110-00 778-110-00 588-845

AR 1 LBT Long VISTA BRITE TIP® SM7333 670-110-0l

AR 1 SH 2 side holes 778-111-00 588-836

AR 1 125 cm SM7296*

AR 2 670-112-00 778-112-00 588-846

AR 2 125 cm SM7360*

AR 2 LBT Long VISTA BRITE TIP® 556-112-0l 670-112-0l

AR 2 SH 2 side holes 670-113-00 778-113-00 588-837

Shape

Shape

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.

JR 5 670-084-00 778-084-00 588-856

JR 5 125 cm SM7359*

JR 5 LBT Long VISTA BRITE TIP® SM7330

JR 5 SH 2 side holes 778-085-00

Right Coronary Judkins Technique

JudKinS RiGht

name picture Observation5F 6F 7F 8F

Shape

Page 32: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

guIdIng CatheterS

tRanSRadial technique

name picture Observation5F 6F 7F 8F

RBL 4 SM7717

RBL 4.5 SM7729

RBL 5 SM7718

CAS 2 SM6877

CAS 3 SM7066

SON 1 SM7166

BL (Tilon) SM7636

RB kimny Technique 556-172-0l 670-172-00

Barbeau 556-174-0l 670-174-00

Barbeau 125 cm SM7713

3D LIMA 90 SM7501

IM Barbeau SM7641 SM7638

JFL 556-162-0l 670-162-00

JFR 556-168-0l 670-168-00

XB 2.5 SM7465

Shape

Transradial / Brachial Technique

Page 33: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

guIdIng CatheterS

Multipurpose

MultipuRpOSe

name picture Observation5F 6F 7F 8F

MPA 1 LBTLong VISTA BRITE TIP®

100 cm556-270-0l

MPA 1 670-270-00 778-270-00 588-842

MPA 1 LBT Long VISTA BRITE TIP® 670-270-0l

MPA 1 SH 2 side holes 670-271-00 778-271-00 588-892

MPA 1 125 cm SM7477* SM7206*

MPA SH 125 cm, 2 side holes SM7482*

MPA 2 125 cm SM7394*

MPB 1 670-272-00

MPB 1 SH 2 side holes 778-273-00

hOcKeY SticK

name picture Observation5F 6F 7F 8F

H-STICk 670-278-00 778-278-00 588-841

H-STICk LBT Long VISTA BRITE TIP® 556-278-0l 670-278-0l

H-STICk SH 2 side holes 670-279-00 778-279-00 588-850

Shape

Shape

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.

Page 34: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

guIdIng CatheterS

Bypass

leFt cOROnaRY BYpaSS

name picture Observation5F 6F 7F 8F

LCB 670-180-00 778-180-00 588-815

LCB LBT Long VISTA BRITE TIP® SM7327

LCB SH 2 side holes 670-181-00 778-181-00

inteRnal MaMMaRY

name picture Observation5F 6F 7F 8F

IM 670-190-00 778-190-00 588-817

IM 90 cm 670-190-90

IM 125 cm SM7370*

IM SH 2 side holes 670-191-00 778-191-00 588-820

IM LBT Long VISTA BRITE TIP® 556-190-0l

RiGht cOROnaRY BYpaSS

name picture Observation5F 6F 7F 8F

RCB 670-182-00 778-182-00 588-816

RCB SH 2 side holes 670-183-00 778-183-00

Shape

Shape

Shape

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.

Page 35: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

guIdIng CatheterS

Long Catheters

long catheters

name Observation5F 6F 7F 8F

AL 1 125 cm SM7438* SM7115* AL 2 125 cm SM7279* AL 3 125 cm SM6988* AR 1 125 cm SM7296* AR 2 125 cm SM7360* BARBEAU 125 cm SM7713* IM 125 cm SM7370* JL 4 125 cm SM7435* SM6987* JL 4 125 cm 2 side holes SM7128*JL 5 125 cm SM7361* SM6731* JR 3.5 125 cm SM7371* JR 4 125 cm SM7436* JR 4 125 cm 2 side holes SM 7444*JR 4 110 cm Long Brite Tip SM7426* JR 5 125 cm SM7359* MPA 125 cm SM7477* SM7206* MPA 1 125 cm 2 side holes SM7482* MPA 2 125 cm SM7394* XB 3 125 cm SM7395* XB 3.5 125 cm SM6991* XB 3.5 120 cm Long Brite Tip SM7400* XB 4 125 cm SM7363*

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.

Page 36: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

guIdIng CatheterS

Long VISTA BRITE TIP®

leFt cOROnaRY JudKinS techniqueJudKinS leFt

name Observation5F 6F 7F 8F

JL 3.5 556-002-0lJL 4 556-004-0l 670-004-0lJL 4.5 SM7329JL 5 556-008-0l

leFt cOROnaRY eXtRa BacK-up ShapeSeXtRa BacK-up

name Observation5F 6F 7F 8F

XB 3.0 SM7328XB 3.5 556-054-0l 670-054-0lXB 3.5 120 cm SM7400*XBLAD 3.5 556-060-0lXB 4 556-056-0l

leFt cOROnaRY aMplatZ techniqueaMplatZ leFt

name Observation5F 6F 7F 8F

AL 1 SM7331 SM7389*AL 2 556-040-0l 670-040-0lAL 3 SM7332

RiGht cOROnaRY JudKinS techniqueJudKinS RiGht

name Observation5F 6F 7F 8F

JR 3.5 556-080-0l SM7390*JR 4 556-082-0l 670-082-0lJR 4 110 cm SM7426*JR 5 SM7330

long ViSta BRite tip®

• Available in 6F .070” & 5F .056” • Safe active back up support through deep seating • Atraumatic ostial coaxial alignment by the excellent tip conformability• Superior tip visibility• Atraumatic Long BRITE TIP

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.

Page 37: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

guIdIng CatheterS

Long VISTA BRITE TIP®

RiGht cOROnaRY aMplatZ techniqueaMplatZ RiGht

name Observation5F 6F 7F 8F

AR 1 SM7333 670-110-0lAR2 556-112-0l 670-112-0l

tRanSRadial / BRachial technique

name Observation5F 6F 7F 8F

JFL 556-162-0lJFR 556-168-0lRB 556-172-0lBARBEAU 556-174-0l

MultipuRpOSeMultipuRpOSe a 1

name Observation5F 6F 7F 8F

MPA 1 556-270-0lMPA 1 670-270-0lMPA 1 SM7401*

hOcKeY SticK

name Observation5F 6F 7F 8F

H-STICk LBT 556-278-0l 670-278-0l

BYpaSSinteRnal MaMMaRY

name Observation5F 6F 7F 8F

IM 556-190-0l

leFt cOROnaRY BY paSS

name Observation5F 6F 7F 8F

LCB SM7327

* Please note that the modified standard catheters will be produced on special request and are subject to longer delivery times and list prices.

Page 38: Cordis Radial Solutions...cordis Radial SolutionS Diagnostic Catheters Barbeau coronary angioplasty via radial access of the left and right coronary arteries. • Primary curve of

guIdIng CatheterS

ECO-PAC FIVE PACS

important information:Prior to use, refer to the “instructions for use” supplied with these devices for indications, contraindications, side effects, suggested procedure, warnings and precautions. As part of the Cordis policy of continuous product development we reserve the right to change product specifications without prior notification.Tel:+32 2 746 30 00 Fax:+32 2 746 34 05© Cordis Europe, a division of Johnson & Johnson Medical N. V. - December 2012 - 2E-800-1991-4

leFt cOROnaRY JudKinS technique

name Observation5F 6F 7F 8F

JL 4 670-004-0e

leFt cOROnaRY eXtRa BacK-up ShapeS

name Observation5F 6F 7F 8F

XB 3.5 670-054-0e

RiGht cOROnaRY JudKinS technique

name Observation5F 6F 7F 8F

JR 4 670-082-0e