® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 1 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
Pre-assembled and tested power panels that are configurable to control multiple load types. Safe panel design offers ease of use with a separate control equipment compartment for link management and interfacing with other systems.
Features
•IntegralHomeWorksR QS processor available
•Supportsupto10totalLQSEDINpowermodules(DPMs):
-Switching(4circuits;maximumof10Atotal)
-PhaseAdaptive(4circuitsofMLV,ELV,orphasecontrolLEDs)
-0–10Vdimmingcontrol(4circuits,maximumof10Atotal)
-EcoSystemR(64ballasts/driversx2links)
-DALIR(64ballasts/driversx2buses)
-Motorloads
•EasyaccesstoIECPELVcontrolequipmentwhichcanincludeatotaloftwo ofthefollowing:
-ContactClosureInterface(QSE-IO)
-DMXInterface(QSE-CI-DMX))
-HomeWorksR QS processor
•Panelsarepre-wiredandtestedpriortoshipping
•Panelsareratedfor220–240V~ and 230V~(CE)applications
•Feed-through,MCB,andRCBOpanelsavailable
•Simpleintegrationofwiredandwirelesssensorsandcontrols
•EasilyintegrateswithLutron®QSdevicesincludingLutron® Sivoia® QS motorized shades
•Integralmanualoverrideswitchturnsalllightsontoaprogrammablelevelwhenactivated(for4A,4T10,and4S10modulesonly)
•Bypassjumpersincludedforloadmis-wireprotection
•Panelsareavailableintwosizes:1613mm(63.5in)and921mm(36.3in)tall
•Frontcoverwithventstomaximizethermalperformanceincluded.
•Optionalblack,powder-coateddoorsavailableforallpanels: –Reversible,hingeddoorwithmagneticlatch –Lockinghingeddooravailableuponrequest
•SchneiderElectricT breakers are used
Note:Seepage17foralistoflinkstocompletespecificationsubmittals
1613mm(63.5in)panel
921mm(36.3 in) panel
Pre-Assembled Lighting Control Panel for HomeWorks® QS
DLDLDLDLL
NNNN
N
DLDLDLDLL
NNNN
N
1122334
4
DLDLDLDLL
NNNN
N
+1-1+2-2+3-3+4-4
DL
DL
DL
DL
L
N
N
N
N
N
DL
DL
DL
DL
L
N
N
N
N
N
DL
DL
DL
DL
L
N
N
N
N
N
DL
DL
DL
DL
L
N
N
N
N
N
+1-1+2-2+3-3+4-4
DL
DL
DL
DL
L
N
N
N
N
N
+1-1+2-2+3-3+4-4
DL
DL
DL
DL
L
N
N
N
NN
DL
DL
DL
DL
L
N
N
N
N
N
1
1
2
2
3
34
4
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 2 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
Regulatory Approvals•CE
Power•Input:230V~(CE);220–240V~(non-CE)50/60Hz (seepanelconfigurationforinputcurrentratings).
•Lightningstrikeprotection:MeetsANSI/IEEEstandardC62.41-2000andIEC61000-4-5.Canwithstandvoltage surgesupto6000 V~ and current surges up to3000 A.
•10yearpowerfailurememory:restoreslightingtolevels prior to power interruption.
•BranchCircuitBreakers:IECrated –Currentrating:10 A –Ratedresidualcurrent(RCBOonly):30 mA –TripCurvecharacteristic:TypeC –Additionalbreaker options available upon request•Standbypower:variesbasedonconfiguration.SeeModuleandControlEquipmentRatings.
DIN Modules Available
(maximum of 10)•PhaseAdaptive*•Switching•Switching/0-10V•Motor (maximum of 8)•DALIR
•EcoSystemR
Note:Onlyatotalof4DALIR/EcoSystemR modules per QSLink
Wiring•Internal:WiredandtestedbyLutron.•System communications:IECPELVwiringconnects
panels to control station.•Line (mains) voltage:feedandloadwiringonly(feed-throughpanelsrequirefeedsforthemodulepower).
Mounting •Surfaceorrecess-mount.
Specifications Construction•1.5mm(16-gauge)galvanizedsheetmetalenclosure(unpainted).
•1.5mm(16-gauge)powder-coated(black)metalcover with ventilation holes.
•Optionaldoor:2.1mm(14-gauge)powder-coated(black)metaldoorwithventilationholes.
Environment•Enclosure:IP-20protection.•Mountwhereambienttemperatureis0 to40 ºC(32to104 °F).Relativehumiditylessthan90%,non-condensing.
•Indooruseonly.•Passivecooling(fanisnotrequired).
Line Voltage (Mains) Connections•Usecopperwireonly,supplyconductors60 °Cto75 °C(140°Fto167°F).
•Feed-throughpanels –DINrail-mountedterminalblocksprovidedfor
line-voltage(mains)powertoDPMsandtocontrolequipment power supply.
–DINrail-mountedterminalblocksprovidedforloadwiring.
•MCBandRCBOpanels –Isolatorswitchprovidedforline-voltage(mains)
power. Power is distributed to branch circuit breakers,modules,andcontrolgearviainternalwiringinstalledbyLutron.
–DINrail-mountedterminalblocksprovidedforloadwiring.
Wire Sizing•DINrail-mountedterminalblockswillaccept: –Line(mains)andloadterminalblockswillaccept
one0.14mm(to6.0 mm2(26AWGto10AWG)wireortwo0.14 mm2to1.5mm2(26AWGto 16AWG)wires.
–0–10Vcontrolsignalterminalblockswillacceptone0.14mm2to1.5 mm2(26AWGto16AWG)wireortwo0.14 mm2to0.75mm2 (26AWGto 20AWG)wires.
•Isolatorswitcheswillacceptone2.5mm2–35mm2 (12AWGto2AWG)wireperpole.
continued on next page* 80Aofdimmingcurrentmaximuminthepanel.
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 3 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
Specifications (continued)
HomeWorksR Processor Panels with processors are referred to as "control"
panels. Panels without processors are also available and are referred to as satellite panels.
•Controlpanelwithprocessorprovides: –AstronomicTimeClock ·SetupusingPCapplication ·Capableofupto500events ·7dailyschedulesand5holiday(special)
schedules are available ·25eventsperday ·Holiday(special)eventsareprogrammableone
year in advance –Ethernetportforlaptopconnectionandnetworking
multiple panels together with processors –Eachprocessorhastwodigitallinkscapableof
controllingupto512zonesand99QSdevices per link
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 4 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
DL
DL
DL
DL
L
N
N
N
N
N
DL
DL
DL
DL
L
N
N
N
N
N
DL
DL
DL
DL
L
N
N
N
N
N
DL
DL
DL
DL
L
N
N
N
N
N
+1-1+2-2+3-3+4-4
DL
DL
DL
DL
L
N
N
N
N
N
+1-1+2-2+3-3+4-4
DL
DL
DL
DL
L
N
N
N
NN
DL
DL
DL
DL
L
N
N
N
N
N
1
1
2
2
3
34
4
QS Link
Wallstation
Up to 99total QS devices
(4) switched outputs, 10 A total (maximum 10 A per channel)
(4) 0-10 V outputs (zones 1-4) }}
Motor Control Power Module
4 motor control outputs, 1.5 A each (zones 1-4) (cannot be used for non-motor loads)
}
Adaptive Power Module
iPad
Laptop
Ethernet Wireless router
(by others)
RGRAFIK Eye QS QS Contact Closure Interface
SivoiaR QS Shades
(4) switched outputs, 10 A total (maximum 10 A per channel)
}
Radio Powr SavrTM occupancy/vacancy sensor (up to 10 per QSM)
Radio Powr SavrTM
daylight sensor (up to 10 per QSM)
Pico® wireless control(up to 10 per QSM)
220−240 V ~ Panel Feed
DALI® Bus 1
DALI® Bus 2 Ballast
Ballast
Up to 64 ballasts & Drivers on each link
Eco Link 1
Eco Link 2 Ballast Ballast
Ballast
Ballast
Ballast
Ballast
Up to 64 ballasts & Drivers on each link
Marshalling Box
(by others)
OPTIONAL
To DALI fittingsTo DALI fittings
To DALI fittingsTo DALI fittings
IEC PELV Control equipment:(maximum 2 pieces
total per panel)- HQP6-2
- QSE-CI-DMX- QSE-IO
Switching Power Module
Switching/0-10V Power Module
EcoSystemR Control Module
DALIR Control Module
800 W Adaptive Load500 W Adaptive Load500 W Adaptive Load500 W Adaptive Load
(Link 1)
QSM
HomeWorksR QS RF Link
AddTest
Setup
WiredRF
Communication
Repeater Status1 3 42 P
Hybrid Repeater
Power Repeater LinkCO
M
24 V9 V
1
MU
X
MU
X
2 3 4
ActivateTest
Hybrid Repeater
AddTest
Setup
WiredRF
Communication
Repeater Status1 3 42 P
Hybrid Repeater
Power Repeater LinkCO
M
24 V9 V
1
MU
X
MU
X
2 3 4
ActivateTestAddTest
Setup
WiredRF
Communication
Repeater Status1 3 42 P
Hybrid Repeater
Power Repeater LinkCO
M
24 V9 V
1
MU
X
MU
X
2 3 4
ActivateTest
HomeWorksR QS RF Link
HomeWorksR QS RF Device HomeWorksR QS
RF DeviceHomeWorksR QS RF Device
HomeWorksR QS Hybrid RepeaterHomeWorksR QS
Processor HQP6-2
System Diagram
iPadisatrademarkofAppleInc.,registeredintheU.S.andothercountries.
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 5 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
Panel Configuration Nomenclature
Branch Circuit Breaker Options
B=MCBBreaker10AR=RCBOBreaker10ABlank=Feed-through
Enclosure Sizes3=921mm(36in)enclosure6=1613mm(64in)enclosure
Panel Options
C=ControlPanel(controlequipmentcompartment)S=SatellitePanel(modulesonly,nocontrolequipment)
Feed Types
L4=3Ø4W(125AIsolatorSwitch)
L2=1Ø2W(63AIsolatorSwitch)
FT=Feed-through(10Aperfeedmaximum)
EnclosureSize
LinkPowerSupply
FeedType
Note: Thefollowinginformationisgivenforgeneraluseonly.ConsultLutronforavailablemodulecombinationsandassistance with specifying module and control equipment.
H Q _ P _ _ - ___ - _ A _ M _ S _ T _ E _ D - _ P _ X _ C - _
DIN Modules *
_A=FourOutputPhaseAdaptiveDimming_M=MotorModule_S=Four-CircuitSwitching_T=Four-Circuit0–10V_E=EcoSystemR2-LinkControl_D=DALIRControlModule
Control Equipment Options (maximum of 2 in control panel)
_P=Processor(seepage3)
_X=DMXControl_C=ContactClosureInterface
Link Power Supply (control panels only)
L=PowerSupply(requiredifpanelcontainsprocessor)
Blank=NoPowerSupply
* DIN Module Count
921 mm (36.3 in) control panel = 3modulesmaximumwithbreakers 4modulesmaximumwithoutbreakers
921 mm (36.3 in) satellite panel = 4modulesmaximumwithbreakers 5modulesmaximumwithoutbreakers
1613 mm (63.5 in) control panel = 8modulesmaximumwithbreakers 9modulesmaximumwithoutbreakers
1613 mm (63.5 in) satellite panel = 9modulesmaximumwithbreakers 10modulesmaximumwithoutbreakers
DINModules:QuantityandType ControlEquipmentOptions
BranchCircuitBreakerOption
Panel Option
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 6 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
LOA
D W
IRIN
G T
HIS
SID
E
PanelConfiguration:H Q R P 6 C - L 4 - 4 A 2 S 2 T - 1 P 1 C - L
Feed Wiring
IEC Class 2 Barrier
Load Terminal Blocks (ships with bypass jumpers installed)
Phase-Adaptive module
Switching ModuleModule Input RCBO Breaker
Control Equipment Breaker
Switching / 0-10 V Module
Manual Override Switch
Example Configurations
RCBOPanel(ModelHQRP6C-L4-230PNL)
3Ø 4W Isolator (ISO) Switch (3P+N)
Wire Landing Boards (WLB) for QS Link - 1 Included* - 2nd WLB available for purchase *5+ DALI/EcoSystem and/or 2 processors includes 2 WLB
ExampleHQRP6C-L4-4A2S2T-1P1C-L:1613mm(63.5in)RCBOcontrolpanelwith(4)phaseadaptivemodules,(2)switchingmodules,(2)0–10V-modules,(1)HomeWorksRQSprocessor,(1)QSE-IOinterfaceand(1)linkpowersupply.
HomeWorksR QS Processor
QSE-IO Interface
Link Power Supply
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 7 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
DLDLDLDLL
NNNN
N
DLDLDLDLL
NNNN
N
DLDLDLDLL
NNNN
N
DLDLDLDLL
NNNN
N
DLDLDLDLL
NNNN
N
+1-1+2-2+3-3+4-4
DLDLDLDLL
NNNN
N
+1-1+2-2+3-3+4-4
DLDLDLDLL
NNNNN
DLDLDLDLL
NNNN
N
1122334
4
LOA
D W
IRIN
G T
HIS
SID
E
Example Configurations (continued)
Feed-ThroughPanel(ModelHQP6C-230-PANEL)
PanelConfiguration:H Q P 6 C - F T - 4 A 1 M 1 S 1 T 2 E - 1 P 1 X - L
Feed and Load (ships with bypass jumpers installed)
IEC PELV Barrier
Phase-Adaptive module
Motor module
Switching module
Switching / 0-10 V module
Manual Override Switch
EcoSystemR Module
Processor
DMX Interface
Power Supply
ExampleHQP6C-FT-4A1M1S1T2E-1P1X-L:1613mm(63.5in)feed-throughcontrolpanelwith(4)phaseadaptivemodules,(1)motormodule,(1)switchingmodule,(1)0–10V-module,(2)EcoSystemRmodules,(1)HomeWorksRQSprocessor,(1)QSE-CI-DMXinterfaceand(1)linkpowersupply.
Wire Landing Boards (WLB) for QS Link - 1 Included* - 2nd WLB available for purchase *5+ DALI/EcoSystem and/or 2 processors includes 2 WLB
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 8 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
Panel Without Optional Door (as shipped):
Access to module user interface
Front Cover (included)
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 9 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
PD-64-Door Dimensions: Fits 1613 mm panel1613mm(63.5in)panelwithoptionaldoorshownbelow.Doorcanbeinstalledasswingleftorswingright(seepage11ofthisdocument).
485 mm (19.1 in)144 mm (5.7 in)
1613 mm (63.5 in)
Optional Doors Available:
Continued on the next page
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 10 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
PD-36-Door Dimensions921mm(36.3in)panelwithoptionaldoorshownbelow.Doorcanbeinstalledasswingleftorswingright(seepage11ofthisdocument).
485 mm (19.1 in)144 mm (5.7 in)
931 mm (36.7 in)
Optional Doors Available: (Continued)
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 11 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
Panel Door Mounting Options and Swing Clearances
921mm(36.3in)panelshownforreference.
SwingLeft SwingRight
Optionalpaneldoorkitincludeshingesandmountinghardwarethatcanbeconfiguredtoswingleftorright.Allow610mm(24 in)forswingclearance.Doorshaveablack,powder-coatedfinish.Kitcanbeinstalledafterpanelinstallation,butrequiresremovaland reinstallationofthedeadfront(flatcover).Standarddoorhasamagnetic catch.
108 mm (4.2 in)
108 mm (4.2 in)
485 mm (19 in)
485 mm (19 in)
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 12 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
•Forindooruseonly.•Consultdimensionspageforpanelsize,conduitknockouts,andmountingholelocations.
•Panelsweighupto50kg(110lb).Reinforcewallstructure for weight and local codes.
•Mountpanelwhereaudiblenoiseisacceptable(internalrelaysclick).
•Thisequipmentispassivelyair-cooled.Mountinalocation where the vented cover will not be blocked. 305 mm(12 in)ofclearanceinfrontoftheventsisrequired.Ventsmustnotbeblockedorthewarrantywill be voided.
•Mountpanelsoline(mains)voltagewiringisatleast1.8 m(6 ft)fromsoundorelectronicequipmentandwiring.
•Forsurfacemount,mountthepanelaminimumof152 mm(6in)fromthefloorand305mm(12 in)fromthe ceiling.
•Mountpanelusingoneofthemethodsbelow(mountinghardwareisnotprovided):
Surface Mounting
•Lutronrecommendsusing6 mm(1/4in)mountingbolts.•Leave32 mm(1.25in)clearanceoneachsideofpanel
for cover.•Usekeyholeswithboltssufficientfor50kg(110lb)load,M6(1/4in)boltsrecommended.
Recess Mounting•Mountpanelbetweenflushand32 mm(0.125 in)
below finished wall surface.•Leave38mm(1.5in)clearanceoneachsideof
panel for cover.•Use screws sufficient for 50kg(110lb).
•Mountwithin7ºoftruevertical.•Installinaccordancewithalllocalandnational
electrical codes.•Ifusingoptionalhingeddoor,allow610mm(24 in)
for swing clearance.•Donotstack1613mm(63.5in)panels.Ifstacking921mm(36.3in)panels,allowatleast305mm(12 in)betweenpanels.
Mounting for Panels
Number of modules
Maximum Heat Dissipation*
BTUs (kcal)/h Watts (W)1 90(22.68) 26
2 170(42.84) 50
3 250(63.00) 73
4 330(83.16) 97
5 410(103.32) 120
6 490(123.48) 144
7 570(143.64) 167
8 650(163.80) 190
9 650(163.80) 190
10 650(163.80) 190
* BasedonPhase-Adaptive(4A)Modules.Panelderatingof80Adimmingcurrentmaxappliesforpanelswithmorethan8modules.
DL
DL
DL
DL
L
N
N
N
N
N
DL
DL
DL
DL
L
N
N
N
N
N
DL
DL
DL
DL
L
N
N
N
N
N
DL
DL
DL
DL
L
N
N
N
N
N
+1-1+2-2+3-3+4-4
DL
DL
DL
DL
L
N
N
N
N
N
+1-1+2-2+3-3+4-4
DL
DL
DL
DL
L
N
N
N
NN
DL
DL
DL
DL
L
N
N
N
N
N
1
1
2
2
3
34
4
DL
DL
DL
DL
L
N
N
N
N
N
DL
DL
DL
DL
L
N
N
N
N
N
DL
DL
DL
DL
L
N
N
N
N
N
DL
DL
DL
DL
L
N
N
N
N
N
+1-1+2-2+3-3+4-4
DL
DL
DL
DL
L
N
N
N
N
N
+1-1+2-2+3-3+4-4
DL
DL
DL
DL
L
N
N
N
NN
DL
DL
DL
DL
L
N
N
N
N
N
1
1
2
2
3
34
4
PreferredFeedWiringPreferredFeedWiring
AlternateFeedWiring
Do Not Block Vents MinimumClearance 305mm (12in)
IECPELV Wiring
IECPELVWiring
AlternateFeedWiring
TerminalBlocksforLoads
FeedWiring(feed-through only)andLoadWiring
TerminalBlocks for loads
Front View Front View Side View Side View
Minimum13mm(6in)
Minimum305mm(12in)
Do Not Block Vents MinimumClearance 305mm (12in)
Minimum13mm(6in)
Minimum100mm(4in)
Minimum100mm(4in)
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 13 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
Mounting Dimensions1613mm(63.5in)panel
467 mm (18.4 in)
108 mm (4.2 in) 5
0.00
0.000.00
54 mm (2.1 in)
174 mm (6.8 in)
306 mm (12.0 in)
438 mm (17.2 in)
570 mm (22.4 in)
702 mm (27.6 in)
834 mm (32.8 in)
966 mm (38.0 in)
1 559 mm (61.4 in)
54 mm (2.1 in)
81 mm (3.2 in) 5
56 mm (2.2 in) 5
31 mm (1.2 in) 5
1 559 mm (61.4 in)
102 mm (4.0 in)
152 mm (6.0 in)
33 mm (1.3 in) diameter 2
26 mm (1.0 in) diameter 3
51 mm (2.0 in) diameter 4
44 mm
(1.75 in)
386 mm
(15.2 in)
81 mm (3.2 in) 5
50 mm (2.0 in)
25 mm (1.0 in)
Typical
Typical
Typical
56 mm (2.2 in) 5
31 mm (1.2 in) 5
291 mm
(11.5 in)
266 mm
(10.5 in)
317 mm
(12.5 in)
330 mm (13 in)
1613 mm (63.5 in)
1150 mm (45.3 in)
56 mm (2.2 in)
124 mm (4.9 in) 1, 5
1 Maximum dimension shown with phase-adaptive module.2 All medium knockouts shown are 33 mm (1.3 in) diameter.3 All small knockouts shown are 26 mm (1.0 in) diameter.4 All large knockouts shown are 51 mm (2.0 in) diameter. 5 Dimensions shown from wall mounting surface.
0.00
40 m
m
(1.6
in)
131
mm
(5
.2 in
)
190
mm
(7
.5 in
)
259
mm
(1
0.2
in)
323
mm
(1
2.7
in)
390
mm
(1
5.3
in)
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 14 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
Mounting Dimensions921mm(36.3in)panel
467 mm (18.4 in)108 mm (4.2 in) 5
330 mm (13 in)
921 mm (36.3 in)
584 mm (23.0 in)
56 mm (2.2 in)
124 mm (4.9 in) 1, 5
0.00
44 mm
(1.75 in)
386 mm
(15.2 in)
81 mm (3.2 in) 5
56 mm (2.2 in) 5
31 mm (1.2 in) 5291 m
m
(11.5 in)
317 mm
(12.5 in)
0.00
131
mm
(5
.2 in
)
190
mm
(7
.5 in
)
259
mm
(1
0.2
in)
323
mm
(1
2.7
in)
390
mm
(1
5.3
in)
0.00
54 mm (2.1 in)
867 mm (34.2 in)
102 mm (4.0 in)
152 mm (6.0 in)
0.00
54 mm (2.1 in)
275 mm (10.8 in)
135 mm (5.3 in)
415 mm (16.3 in)
867 mm (34.2 in)
81 mm (3.2 in) 5
56 mm (2.2 in) 5
31 mm (1.2 in) 5
50 mm (2.0 in)
25 mm (1.0 in)
Typical
Typical
Typical
33 mm (1.3 in) diameter 2
26 mm (1.0 in) diameter 3
51 mm (2.0 in) diameter 4
1 Maximum dimension shown with phase-adaptive module.2 All medium knockouts shown are 33 mm (1.3 in) diameter.3 All small knockouts shown are 26 mm (1.0 in) diameter.4 All large knockouts shown are 51 mm (2.0 in) diameter. 5 Dimensions shown from wall mounting surface.
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 15 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
DL1
DL2
DL3
DL4
L1
N
N
N
N
N
Wire Sizes•Line (Mains) Feed (to isolator switch): 2.5mm2(12AWG)to35mm2(2AWG)
• Neutral Feed (to isolator switch): 2.5mm2(12AWG)to35mm2(2AWG)
• Dimmed Live (to terminal block): 0.14mm2(26AWG)to6.0mm2(10AWG)
•Load Neutral (to terminal block): 0.14mm2(26AWG)to6.0mm2(10AWG)
Wiring Tips WirethepanelsimilartoaLightingDistributionPanel:
•RunfeedandloadwiringtoappropriateterminalblocksorIsolatorswitchinstalledinpanel.
•Forfeedthroughpanelsrunseparateneutralsforeachmodule–nocommonneutralsacrossphases.
•Thepanelcanprovidetemporarylighting:–Wireallloads.–Donotremovebypassjumpersthatarepre-
installed for load controlling modules.–Usepre-installedBreakerstoswitchlightson
and off.
Panel Wiring
ISO Switch
Neutral Feed
Line (Mains) Feed
Bypass Jumpers: Do not remove until load wiring is verified.
Terminal Blocks
Dimmed Line
Load Neutral
Load
IECPELVwiringlink(seenextpagefordetails)
Wallstation
IEC PELV Wiring•IECPELVwiringisusedforallsystemcommunications.•IECwiringmustruninaseparatetroughfromline(mains)
voltage.•Mustbelessthan600 m(2000ft)long.
Phase-Adaptive module
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 16 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
DLDLDLDLL
NNNN
N
DLDLDLDLL
NNNN
N
1122334
4
DLDLDLDLL
NNNN
N
+1-1+2-2+3-3+4-4
Configurable Link Wiring: QS Devices
Notes•SystemcommunicationusesIECwiring.
•FollowalllocalandnationalelectricalcodeswheninstallingIECwiringwithlinevoltage/mainswiring.
•Eachterminalacceptsuptotwo1.0mm2(18AWG)wiresorone4.0mm2 to0.5mm2(12AWGto22AWG) wire.
•Makeallconnectionsinsidethepanel.
•AQSlinkcanhaveupto512zonesand99devices.RefertotheQSLinkPowerDrawUnitsSpecificationSubmittal(LutronRPN369405)andthetableaboveforinformationconcerningPowerDrawUnits(PDUs).
•WiringcanbeT-tappedordaisy-chained.
(5)Drain(Shield)(4)_(3)MUX(2)24V-(1)COM
QS Link Wiring:0.5 mm(to4.0 mm(
(22 AWGto12 AWG)
Tightenterminalblocksto0.6 N•mto0.8 N•m(5.3 in-lbto7.1 in-lb).Donotovertighten.
QS Link Wiring with Available Power Supply (QSPS-DH-60-1)
Available Power Draw Units (PDUs) per link
Maximum Link Length
Wire Gauge RequiredAvailable from Lutron in one cable
32150m (500ft)
Power(terminals1and2) 1pair1.0mm2(18AWG)Data(terminals3and4)1pair0.5mm2(22AWG) twisted and shielded
QSH-CBL-M-500 QSH-CBLP-M-500
32600m (2000ft)
Power(terminals1and2) 1pair4.0mm2(12AWG)Data(terminals3and4)1pair0.5mm2(22AWG) twisted and shielded
QSH-CBL-L-500 QSH-CBLP-L-500
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 17 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
DLDLDLDLL
NNNN
N
DLDLDLDLL
NNNN
N
1122334
4
DLDLDLDLL
NNNN
N
+1-1+2-2+3-3+4-4
EcoSystemR/DALIR Modules
QSLink1*
QSLink2*
QS Device Description Switch Leg Count
Digital Controls (Energi Savr NodeT QS)
1 per EcoSystemR/DALIR address used
(128 maximum)
Phase Adaptive Fixture Controls(Energi Savr NodeT QS)
4
Switching Controls(Energi Savr NodeT QS)
4
0-10V Controls (Energi Savr NodeT QS)
4
Motor Controls(Energi Savr NodeT QS)
4
seeTouchR QS 0
SivoiaR QS Roller 64T 1
SivoiaR QS Roller 100T 1
SivoiaR QS Roller 225T 1
QS contact closure interface up to 5
QS Link Limits•EachQSLinkiscapableofsupporting512switchlegs(controllableoutputs)•QuantumRprocessorsareequippedwithtwoQSLinks
QS Device Consumption Rules
ThetablebelowlistssomeofthedevicesavailableontheQSLinkandthenumberofswitchlegseachwillconsume.Thislistisforreferenceonlyandisnotallinclusive.
QS Link Management
•4EcoSystemR/DALIR modules or less –1WireLandingBoardwiredtoasingleQSlink–2ndWireLandingBoard(Optional-PurchaseSeparately)
• 5EcoSystemR/DALIR modules or more–2WireLandingBoards–EachWireLandingBoardwiredtoseparateQSLinks–Bottom4moduleswiredtoQSLink1–RemainingtopmodulesarewiredtoQSLink2
It is the responsibility of the installer to connect QS Link cables to the Wire Landing Board correctly in accordance to the above
* QS Link Number terminology used for explanation only
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 18 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
Number of Processors in Panel
ECO/Dali Modules
QS Link Wiring - Installation Guide
04orless ConnectQSLinktosinglewirelandingboardfromexternalprocessor
5ormoreConnectseparateQSLinkstowirelandingboards1and2.WirelandingboardscannotsharethesameQSLink.
1
4orless
ProcessorprewiredwithLink1(L1)toallmodules.ExternalzonesshouldbewiredtoLink2(L2)onprocessorifapplicable.
-2ndwirelandingboardavailableasfieldinstallableoption
5ormore
ProcessorprewiredwithLink1(L1)toupperwirelandingboard(bottom4modules)andLink2(L2)tolowerwirelandingboard(allremainingmodules).Externalzonesshouldbewiredaccordingtojobspecification,preferablyanexternalprocessor.See"QSLinkDiagram1"below.
2
4orless
Processor1(P1)prewiredwithP1Link1(L1)ontopwirelandingboard(allmodules),P1Link2(L2)isopen.Processor2(P2)isprewiredwithP2Link1(L1)onbottomlandingboard(nomodules),P2Link2(L2)isopen.AllexternalzonesshouldbewiredtoP1L2,P2L1,orP2L2.See"QSLinkDiagram2"below.
5ormore
Processor1(P1)isprewiredwithP1Link1(L1)onupperwirelandingboard(bottom4modules),P1Link2(L2)isopen.Processor2(P2)prewiredwithP2Link1(L1)onlowerwirelandingboard(allremainingmodules),P2Link2(L2)isopen.AllexternalzonesshouldbewiredtoP1L2orP2L2.See"QSLinkDiagram2"below.
It is the responsibility of the installer to connect QS Link cables to the Wire Landing Board correctly in accordance to the above
LUTRONCoopersburg, PA 18036 USA
PELV (CLASS 2:USA)
800.523.9466+1.610.282.3800www.lutron.com
L2 TX/RXL2L1 TX/RXL1
P
ERR
PWR
P TX/RX
CO
M
P L1 L2
24V500 mA
24V2 A
RJ45, 10/100 RJ45, 10/100
L2 L1
LUTRONCoopersburg, PA 18036 USA
PELV (CLASS 2:USA)
800.523.9466+1.610.282.3800www.lutron.com
L2 TX/RXL2L1 TX/RXL1
P
ERR
PWR
P TX/RX
CO
M
P L1 L2
24V500 mA
24V2 A
RJ45, 10/100 RJ45, 10/100
L2 L1
LUTRONCoopersburg, PA 18036 USA
PELV (CLASS 2:USA)
800.523.9466+1.610.282.3800www.lutron.com
L2 TX/RXL2L1 TX/RXL1
P
ERR
PWR
P TX/RX
CO
M
P L1 L2
24V500 mA
24V2 A
RJ45, 10/100 RJ45, 10/100
L2 L1
LUTRONCoopersburg, PA 18036 USA
PELV (CLASS 2:USA)
800.523.9466+1.610.282.3800www.lutron.com
L2 TX/RXL2L1 TX/RXL1
P
ERR
PWR
P TX/RX
CO
M
P L1 L2
24V500 mA
24V2 A
RJ45, 10/100 RJ45, 10/100
L2 L1
P1 P2
LUTRONCoopersburg, PA 18036 USA
PELV (CLASS 2:USA)
800.523.9466+1.610.282.3800www.lutron.com
L2 TX/RXL2L1 TX/RXL1
P
ERR
PWR
P TX/RX
CO
M
P L1 L2
24V500 mA
24V2 A
RJ45, 10/100 RJ45, 10/100
L2 L1
LUTRONCoopersburg, PA 18036 USA
PELV (CLASS 2:USA)
800.523.9466+1.610.282.3800www.lutron.com
L2 TX/RXL2L1 TX/RXL1
P
ERR
PWR
P TX/RX
CO
M
P L1 L2
24V500 mA
24V2 A
RJ45, 10/100 RJ45, 10/100
L2 L1
LUTRONCoopersburg, PA 18036 USA
PELV (CLASS 2:USA)
800.523.9466+1.610.282.3800www.lutron.com
L2 TX/RXL2L1 TX/RXL1
P
ERR
PWR
P TX/RX
CO
M
P L1 L2
24V500 mA
24V2 A
RJ45, 10/100 RJ45, 10/100
L2 L1
LUTRONCoopersburg, PA 18036 USA
PELV (CLASS 2:USA)
800.523.9466+1.610.282.3800www.lutron.com
L2 TX/RXL2L1 TX/RXL1
P
ERR
PWR
P TX/RX
CO
M
P L1 L2
24V500 mA
24V2 A
RJ45, 10/100 RJ45, 10/100
L2 L1
LUTRONCoopersburg, PA 18036 USA
PELV (CLASS 2:USA)
800.523.9466+1.610.282.3800www.lutron.com
L2 TX/RXL2L1 TX/RXL1
P
ERR
PWR
P TX/RX
CO
M
P L1 L2
24V500 mA
24V2 A
RJ45, 10/100 RJ45, 10/100
L2 L1
LUTRONCoopersburg, PA 18036 USA
PELV (CLASS 2:USA)
800.523.9466+1.610.282.3800www.lutron.com
L2 TX/RXL2L1 TX/RXL1
P
ERR
PWR
P TX/RX
CO
M
P L1 L2
24V500 mA
24V2 A
RJ45, 10/100 RJ45, 10/100
L2 L1
LUTRONCoopersburg, PA 18036 USA
PELV (CLASS 2:USA)
800.523.9466+1.610.282.3800www.lutron.com
L2 TX/RXL2L1 TX/RXL1
P
ERR
PWR
P TX/RX
CO
M
P L1 L2
24V500 mA
24V2 A
RJ45, 10/100 RJ45, 10/100
L2 L1
LUTRONCoopersburg, PA 18036 USA
PELV (CLASS 2:USA)
800.523.9466+1.610.282.3800www.lutron.com
L2 TX/RXL2L1 TX/RXL1
P
ERR
PWR
P TX/RX
CO
M
P L1 L2
24V500 mA
24V2 A
RJ45, 10/100 RJ45, 10/100
L2 L1
QS Link Diagram 1 QS Link Diagram 2
QS Link Management
ThetablebelowprovidesareferenceformanagingtheQSLinkwiringtoandfrompanelsequippedwithEcoSystemR/DALIR modules.
EcoSystemR/DALIR Modules (continued)
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
369846b 19 04.01.16
HomeWorks® QS DIN Rail Panel Power Equipment
Module and Interface Specification Submittals
Product P/N
PhaseAdaptiveDINPowerModule 369583
0–10 V/SwitchingModule 369610
DINPowerModulewithEcoSystemR 369611
DINPowerModulewithDALIModule,DINPower 369650
MotorControlModule 369614
QSE-CI-DMXControlInterface 369372
QSE-IOControlInterface 369374
Power Supply 369404
PowerDrawUnits(PDU) 369405
QSWireLandingBoard 369662