2
Kaydon Custom Filtration Corporation DS-1006-TE Competitor Performance Results Beta Results at 4 micron Competitor Analysis Kaydon Custom Filtration regularly tests competitor elements against its own. Recent testing of the Kaydon Turbo-TOC ® elements against four principal competitors for particulate elements, coalescers and separators revealed the performance advantage of using and main- taining Kaydon element technology in the Turbo-TOC ® systems, or changing from these competitors to Kaydon. The tests, conducted internally to Kaydon using its own laboratory, represent a valid comparison of where we stand against those who have attempted to copy Kaydon’s Turbo-TOC ® elements. Ultimately, they reveal the best protection for your turbine bearings is with the new “advanced” KL series of Turbo-TOC ® elements; they can save you money on turbine oil and bearing maintenance and better protect against a possible leaking seal. *Testing per ISO 16889, Best rated micro slots elements. Turbo-TOC ® Elements Kaydon Bowser Competitor V Competitor F Competitor H Competitor R K1100 K2100 K3100 Prefilter Coalescer* Separator *patent pending Water Removal Efficiency Total Water Capabiility Competitor F Competitor H Competitor V Kaydon 94.9 97.6 97.8 98.3 Kaydon Competitor V Competitor H Bowser Competitor F Competitor R 400 300 200 100 0 * Average single pass efficiency over course of water removal testing, based on Karl Fischer. * Analysis of inlet and outlet samples. Information on Competitor R and Bowser Systems is available by request. * Total water content by Karl Fischer analysis during Kaydon testing as defined: based upon a constant initial water ingression of 5000 ppm; test run at 120°F (49°C), 6 gpm. 2500 50 400 225 450 6

Competitor Analysis · 2018-10-10 · Competitor F Competitor H Competitor V Kaydon 94.9 97.6 97.8 98.3 Kaydon Competitor V Competitor H Bowser Competitor F Competitor R 400 300 200

  • Upload
    others

  • View
    51

  • Download
    1

Embed Size (px)

Citation preview

Kaydon Custom Filtration Corporation DS-1006-TE

Competitor Performance ResultsBeta Results at 4 micron

Competitor Analysis

Kaydon Custom Filtration regularly tests competitor elements against its own. Recent testing of the Kaydon Turbo-TOC® elements against four principal competitors for particulate elements, coalescers and separators revealed the performance advantage of using and main-taining Kaydon element technology in the Turbo-TOC® systems, or changing from these competitors to Kaydon. The tests, conducted internally to Kaydon using its own laboratory, represent a valid comparison of where we stand against those who have attempted to copy Kaydon’s Turbo-TOC® elements. Ultimately, they reveal the best protection for your turbine bearings is with the new “advanced” KL series of Turbo-TOC® elements; they can save you money on turbine oil and bearing maintenance and better protect against a possible leaking seal.

* Testing per ISO 16889, Best rated micro slots elements.

Turbo-TOC® Elements

Kaydon

Bowser

Competitor V

Competitor F

Competitor H

Competitor R

K1100 K2100 K3100 Prefi lter Coalescer* Separator*patent pending

Water Removal Effi ciency Total Water Capabiility

Competitor F

Competitor H

Competitor V

Kaydon

94.9

97.6

97.8

98.3 Kaydon Competitor V Competitor H Bowser Competitor F Competitor R

400

300

200

100

0

* Average single pass effi ciency over course of water removal testing, based on Karl Fischer.

* Analysis of inlet and outlet samples. Information on Competitor R and Bowser Systems is available by request.

* Total water content by Karl Fischer analysis during Kaydon testing as defi ned: based upon a constant initial water ingression of 5000 ppm; test run at 120°F (49°C), 6 gpm.

2500

50

400

225

450

6

1571 Lukken Industrial Drive West • LaGrange, Georgia USA 30240Phone: 1 (800) 241-2342 • 1 (706) 884-3041 • Fax: (706) 883-6199Web: www.kaydonfi ltration.com • Email: fi [email protected]©2006, Kaydon Corporation

Kaydon Custom

Filtration Corporation

DS-1006-TE

E X T E N D I N G Y O U R E N E R G Y

Total Performance Average Annual Savings Improvement Against Competitor

Kaydon Bowser Competitor V Competitor F Competitor H Competitor R

Competitor R

Competitor H

Competitor F

Competitor V

Bowser

1

2.2

1.31

2.77

1.43

5.08 $118, 000

$101,000

$145,000

$45,000

$34,000

.65.80

.94

2.08

2.763.0

2.5

2.0

1.5

1.0

0.5

Years

Competitors

$7,000

$29,000

$140,000

$174,000

Kaydon Bowser Competitor R Competitor F Competitor H Competitor V

Competitor V Competitor H Competitor F Competitor R

Kaydon Bowser Competitor R Competitor F Competitor H Competitor V

* This factor takes into account total water content of outlet sample, effi ciency of water removal as defi ned above, and best-available particulate fi lter effi ciency for the system. For more information, contact Kaydon product management. A value of 1.0 signifi es equivalence; a value greater than 1.0 gives you an idea of how much better Kaydon Turbo-TOC® elements are, or how much worse is the competitor.

* Based on recommended, regular scheduled maintenance of systems in question and estimated dollar savings for both turbine oil and bearing life. Note: as an insurance policy, protection and potential savings may be even greater.

Payback Competitor's Additional Annual Comparison Projected Maintenance Costs

* This payback is calculated using the more conservative factors of bearing and turbine oil life improvements with a Kaydon Turbo-TOC® system – savings potential. Payback to replace competitior with Kaydon System and Elements.

* Rather than showing savings with Kaydon elements, these values refl ect the additional, potential costs of replacing Turbo-TOC® elements with competitors.

ISO 9001:2000

Certificate No.: 002232