® “Meeting the needs of Commercial Ventilation” Commercial Ventilation Solutions FLEXI MULTI Heat Recovery NEW FLEXI RANGE 95% Thermal Efficiency up to ® ® Commercial Heat Recovery Systems

Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

Embed Size (px)

Citation preview

Page 1: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

“Meeting the needs of Commercial Ventilation”

Commercial Ventilation SolutionsFLEXI MULTI

®®

®

Heat R

ecove

ry

NEW FLEXI RANGE

95%

Therm

al Effic

iencyup

to

®

®

Commercial Heat Recovery Systems

Page 2: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

The indoor climate is of the utmost importance as most of us spend the greater part of our lives indoors. To ensure comfort and a sense of well-being, the air we breathe must be clean, and also be at the right temperature and humidity level. To most people, this is so self-evident that they do not give it a second thought.

Whatever the situation, Mechanical Ventilation with Heat Recovery (MVHR) solutions from Airflow can play a significant role because they help create a healthier living and working environment, while contributing to the reduction of a building's carbon emissions and energy usage.

Unique to the Duplexvent Flexi Line is the ability to position the unit on the floor or in a ceiling suspended position. Also this universal design allows the unit to be installed as either a left or right hand version.

This provides exceptional flexibility for designers in the specification phase and gives contractors the opportunity to locate the unit in the optimum position. Similarly HVAC distributors benefit from a range of “off the shelf” air handling units which can be quickly adapted to fit on-site. No more bespoke orders with long lead times!

FLEXI ®

• Heat Recovery Ventilation • 95% thermal efficiency • Low energy EC fans• Versatile unit positioning • 10 speed digital control • Internet connection• Off the shelf delivery

1 Base Unit (FLEXI DV1100 / 1600 / 2600 / 3600)

16 Installation Configurations

+ 3 Upgrade Packs

2

®®

Features

Floor Standing

Ceiling Suspended

®

Heat R

ecove

ry

NEW FLEXI RANGE

95%

Therm

al Effic

iencyup

to

Page 3: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

Optional water / DX heating and cooling coils help maintain optimum indoor conditions

Versatile unit positioning enables right or left hand configuration on the same unit

Interchangeable spigot design allows the spigot connections to be changed on-site (DV1600)

1. Passive House Pack • Electric pre-heater to warm the incoming air

2. Constant Pressure Pack • Differential pressure and flow measurement for energy optimisation

3. Hygiene Pack • Inclined tube manometers to maintain the certified hygiene standard VDI 6022

Upgrade Packs

airflow.com

FLEXI ®

Whole life cost savings

Building operators and Asset Managers will appreciate the Flexi Line's innovative built-in internet connection with User and Service interface which allows service technicians to connect to the unit from a remote location. By continuously checking the operating status, diagnosing any faults and instructing the user what to do immediately, results in saving onsite call outs, preventive service and down-time to both technician and client. This unique feature minimises the service process as well as creating a secondary control display for the user.

3

Page 4: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

Cross-Counter Flow Heat Exchangers up to 95% thermal efficiency reduce heating bills significantly and guarantee a quick return on investment

Cross-Counter Flow Heat Exchangersup to 95% thermal efficiency reduce heating bills significantly and guarantee a quick return on investment

M5 / F7 High Grade Filters provide ultra hygienic indoor climate and protect heat exchangers from getting dirty

M5 / F7 High Grade Filters provide ultra hygienic indoor climate and protect heat exchangers from getting dirty

Interchangeable Spigot Connections* simplify on-site installationInterchangeable Spigot Connections* simplify on-site installation

100% Summer Bypass Facility provides a flow of cool, fresh and filtered air into the property100% Summer Bypass Facility provides a flow of cool, fresh and filtered air into the property

Digital Control Box with internet and BMS connectionsDigital Control Box with internet and BMS connections

Smooth Internal Casing with 30mm insulation avoids thermal bridging, absorbs noise and meets sanitary standards

Smooth Internal Casing with 30mm insulation avoids thermal bridging, absorbs noise and meets sanitary standards

airflow.com

FLEXI ®

4

Key Components

Page 5: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

* DV1600 only

Temperature Sensors for fully automatic operation of the summer bypass, frost protection and heater / cooler facilities

Temperature Sensorsfor fully automatic operation of the summer bypass, frost protection and heater / cooler facilities

Safety Switch to shut off the power in case of emergencySafety Switch to shut off the power in case of emergency

Lockable Large Access Doors simplify and accelerate themaintenance process

Lockable Large Access Doors simplify and accelerate themaintenance process

Condensate Drain for ceiling - suspended installations

Condensate Drain forceiling - suspended installations

Low energy, maintenance free EC Fan Technology ensures long term savings on operating costs

Low energy, maintenance free EC Fan Technology ensures long term savings on operating costs

Pressure Sensors for filter monitoringPressure Sensors for filter monitoring

Condensate Drain for floor standing installationsCondensate Drain for floor standing installations

airflow.com

FLEXI ®

5

Page 6: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

FLEXI DV1100

• Extracts up to 1100 m³/h (0.31 m³/s) @ 200 Pa• Excellent heat recovery efficiency, up to 95%• Versatile unit positioning with floor and ceiling suspended mounting options• Low SFP with energy saving EC fans• Low noise, refer to NR35 and BB93 standards• 10 speed digital control with Internet and BMS• Compliant to BREEAM, Passive House and

ErP 2013 / 2015 regulations

®

* The above figures are example performance measurements. Please use the Duplexvent Selection Software to calculate measurements at other performance levels.

6

ErP 2013 / 2015 regulations

Performance

Exte

rnal

Sta

tic P

ress

ure

(Pa)

Performance Curve: Sound Parameters:Sound Power Level Lw (dB)

dB(A) 63 125 250 500 1 k 2 k 4 k 8 kOutdoor Air e1 47 68 57 47 42 35 28 <25 <25Supply Air e2 66 80 74 69 62 60 55 49 47Extract Air i1 45 67 55 46 40 33 26 <25 <25Exhaust Air i2Breakout Noise

65 80 72 68 60 58 53 47 4451 70 55 57 44 40 33 27 25

Sound Pressure Level Ld (dB)To the surroundings 21 49 35 37 <25 <25 <25 <25 <25

Sound pressure level is measured at 3 m distance.e, emax-Supply air (230 V), i, imax-Extract air (230 V)

Air Volume (m³/h)

Note: The figures above have been measured at 500 m³/h and 150 Pa.

0 200 400 600 800 1000 12000

200

400

600

800

1000

1200

ei

e,emax

i,imax

Ventilation:

m³/h (m³/s) Air Volume* 500 (0.14) 500 (0.14)External Static Pressure* Pa 150 150Nominal Voltage V 230 230Voltage (at operation point) V 230 230Nominal Power (at operation point)* W 93 87Max. Connection Power 385 385Max. Current A

W2.5 2.5F7 M5

Fan Type EC EC

Motors: e, i - Me.107 (230 V)

Nom

inal

Pow

er (W

)

Filters

Supply Air Extract Air 1100 (0.31) 1100 (0.31)Maximum Air Volume m³/h (m³/s)

Air Volume (m³/h)

0 200 400 600 800 1000 12000

100

200

300

400ei

Heat Recovery:

500 (0.14) 500 (0.14)Temperature at Inlet* °CAir Volume* m³/h (m³/s)

-10 22Temperature at Outlet* °C 17 2Humidity at Inlet* % r h 90 40Humidity at Outlet* % r h 12 100Thermal Efficiency in Winter (Summer) % 84 (80)Performance in Winter (Summer) kW 4.6 (-0.6)Condensation l/h 1.5

Counter Flow, Plastic

Ther

mal

Effi

cenc

y (%

)

---- Winter --- Summer

Type of Heat Exchanger

Air Volume (m³/h)

Supply Air Extract Air 1100 (0.31) 1100 (0.31)Maximum Air Volume m³/h (m³/s)

0 200 400 600 800 1000 120040

50

60

70

80

90

100

Features

Page 7: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

FLEXI DV1100

Supplydescription t [°C] rh [%]

e1 outdoor air -10.0 90eR heat recovery 16.7 12

Exhaustdescription t [°C] rh [%]

i1 extract air 22.0 40i2 heat recovery 1.5 100

e1 - outdoor air (ODA) i1 - extract air (ETA)e2 - supply air (SUP) i2 - exhaust air (EHA)

Winter Operation*:

Note: AHU functions diagram. Inlet and outlet location may differ from actual position and port configuration.

-5

0

5

10

15

20

25

30

3540

4550

h [kJ/kg]

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15x [g/kg of dry air]

-15

-10

-5

0

5

10

15

20

25

30

t [°

C]

100 %90 %80 %

70 %

60 %

50 %40 %30 %20 %10 %

e1

heat recovery4,6 kW

eR=e2

i1

heat recovery-4,6 kW

i2

230 V0,09 kW

S3.B84 %

4,6 kW

�ltration F7�ltration F5

230 V0,09 kW

B

Me.107.EC1

Fe.K7Fi.K5

Mi.107.EC1

-10 °C90 %-10 °C

90 %

17 °C12 %

500 m3/h150 Pa

17 °C12 %

500 m3/h150 Pa

22 °C40 %

22 °C40 %

2 °C100 % 2 °C

97 %

outdoorair

e1

supplyair

e2

exhaustair

extractair

i1

i2

Supplydescription t [°C] rh [%]

e1 outdoor air 22.0 35eR heat recovery 25.2 29

Exhaustdescription t [°C] rh [%]

i1 extract air 26.0 50i2 heat recovery 22.8 61

e1 - outdoor air (ODA) i1 - extract air (ETA)e2 - supply air (SUP) i2 - exhaust air (EHA)

Summer Operation*:

Note: AHU functions diagram. Inlet and outlet location may differ from actual position and port configuration.

-5

0

5

10

15

20

25

30

3540

4550

h [kJ/kg]

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15x [g/kg of dry air]

-15

-10

-5

0

5

10

15

20

25

30

t [°

C]

100 %90 %80 %

70 %

60 %

50 %40 %30 %20 %10 %

e1heat recovery

0,6 kW

eR=e2 i1 heat recovery-0,6 kWi2

230 V0,09 kW

S3.B80 %

-0,6 kW

�ltration F7�ltration F5

230 V0,09 kW

B

Me.107.EC1

Fe.K7Fi.K5

Mi.107.EC1

22 °C35 %22 °C

35 %

25 °C29 %

500 m3/h150 Pa

26 °C28 %

500 m3/h150 Pa

26 °C50 %

26 °C50 %

23 °C61 % 23 °C

59 %

outdoorair

e1

supplyair

e2

exhaustair

extractair

i1

i2

670 370 x 275

K

i1

e2

e1

i2

R250

80

225

R250

80

359

R250

80

225

R250

80

246

670

1700

370 x 275

140

150

1100

KK

R250

159

359

R250

175

225

140

150

R250

175

225

R250

159

395 395

246

140

150

Dimensions: Connections Type Diameter Accessoriese1 Outdoor Air ø 250 mm

ø 250 mmø 250 mmø 250 mm

Shut off Damper, Flexible Connector

e2 Supply Air Flexible Connectori1 Extract Air Flexible Connectori2 Exhaust Air Flexible ConnectorK Condensate

OutletCondensate Trap

Front View LeftRight

Top View

ø 21 mm

Weight = 157kg

®

* The above figures are example performance measurements. Please use the Duplexvent Selection Software to calculate measurements at other performance levels.

7

Sound Insulation - Casing noise reduction:

Casing StrengthEN 1886, mm/m

10

4

0 1

D3

D2

D1

Energy EfficiencyEurovent

A

B

C

D

E

F

Hz dB125 38.3250 35.1500 39.1

1000 38.02000 36.14000 43.28000 46.0

Page 8: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

• Extracts up to 1600 m³/h (0.44 m³/s) @ 200 Pa• Excellent heat recovery efficiency, up to 95%• Versatile unit positioning with floor and ceiling suspended mounting options• Low SFP with energy saving EC fans• Low noise, refer to NR35 and BB93 standards• 10 speed digital control with Internet and BMS • Unique interchangeable spigot connections• Compliant to BREEAM, Passive House and

ErP 2013 / 2015 regulations

0500 1000 1500 20000

200

400

600

800

1000

1200

Exte

rnal

Sta

tic P

ress

ure

(Pa)

Performance Curve: Sound Parameters:Sound Power Level Lw (dB)

dB(A) 63 125 250 500 1 k 2 k 4 k 8 kOutdoor Air e1 46 61 54 49 42 38 31 <25 <25Supply Air e2 68 74 75 70 66 62 58 51 45Extract Air i1 45 61 54 48 42 37 31 <25 <25Exhaust Air i2Breakout Noise

68 74 75 70 65 61 58 50 4455 59 61 59 51 50 44 32 <25

Sound Pressure Level Ld (dB)To the surroundings

Note: The figures above have been measured at 800 m³/h and 150 Pa.

35 38 41 39 30 29 <25 <25 <25

e, emax

i, imaxi, imax

Sound pressure level is measured at 3 m distance.e, emax-Supply air (230 V), i, imax-Extract air (230 V)

Air Volume (m³/h)

FLEXI DV1600

Ventilation:Supply Air Extract Air

Air Volume* 800 (0.22)

1600 (0.44) 1600 (0.44)

800 (0.22)External Static Pressure* Pa

m³/h (m³/s)150 150

Nominal Voltage V 230 230Voltage (at operation point) V

WW

230 230Nominal Power (at operation point)* 114 105Max. Connection Power 505 505Max. Current A 2.9 2.9

F7 M5Fan Type EC EC

Motors: e, i - Me.101 (230 V)

0500 1000 1500 20000

100

200

300

400

500

Nom

inal

Pow

er (W

) e, i

Filters

Air Volume (m³/h)

Maximum Air Volume m³/h (m³/s)

Heat Recovery:

800 (0.22) 800 (0.22)Temperature at Inlet* °CAir Volume* m³/h (m³/s)

-10 22Temperature at Outlet* °C 18 1Humidity at Inlet* 90 40Humidity at Outlet* % r h 11 100Thermal Efficiency in Winter (Summer) % 87 (84)Performance in Winter (Summer) kW 7.7 (-0.9)Condensation l/h 2.5

Counter Flow, Plastic

40500 1000 1500 20000

50607080

10090

Ther

mal

E�

cenc

y (%

)

---- Winter --- Summer

Type of Heat Exchanger

Air Volume (m³/h)

Supply Air Extract Air 1600 (0.44) 1600 (0.44)Maximum Air Volume m³/h (m³/s)

% r h

®

* The above figures are example performance measurements. Please use the Duplexvent Selection Software to calculate measurements at other performance levels.

8

Features

Performance

Page 9: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

230 V0.11 kW

S4.A.H87 %

7.7 kW

filtration F7filtration F5

230 V0.10 kW

B

Me.101.EC1

Fe.K7Fi.K5

Mi.101.EC1

-10 °C90 %-10 °C

90 %

18 °C11 %

800 m³/h150 Pa

18 °C11 %

800 m³/h150 Pa

22 °C40 %

22 °C40 %

1 °C100 % 1 °C

98 %

outdoorair

e1

supplyair

e2

exhaustair

extract air

i1

i2

-5

0

5

10

15

2025

3035

4045

50

h [kJ/kg]

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15x [g/kg of dry air]

-15

-10

-5

0

5

10

15

20

25

30

t [°C

]

100 % 90 % 80 % 70 % 60 %

50 %40 %30 %20 %10 %

e1

heat recovery7.7 kW

eR=e2

i1

heat recovery-7.7 kW

i2

Supplydescription t [°C] rh [%]

e1 outdoor air -10.0 90eR heat recovery 17.8 11

Exhaustdescription t [°C] rh [%]

i1 extract air 22.0 40i2 heat recovery 0.9 100

e1 - outdoor air (ODA) i1 - extract air (ETA)e2 - supply air (SUP) i2 - exhaust air (EHA)

Winter Operation*:

Note: AHU functions diagram. Inlet and outlet location may differ from actual position and port configuration.

FLEXI DV1600®

e1 - outdoor air (ODA) i1 - extract air (ETA)

Summer Operation*:

230 V0.11 kW

S4.A.H84 %

-0.9 kW

filtration F7filtration F5

230 V0.10 kW

B

Me.101.EC1

Fe.K7Fi.K5

Mi.101.EC1

22 °C35 %22 °C

35 %

25 °C29 %

800 m³/h150 Pa

26 °C28 %

800 m³/h150 Pa

26 °C50 %

26 °C50 %

23 °C61 % 23 °C

60 %

outdoorair

e1

supplyair

e2

exhaustair

extractair

i1

i2

-5

0

5

10

15

2025

3035

4045

50

h [kJ/kg]

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15x [g/kg of dry air]

-15

-10

-5

0

5

10

15

20

25

30

t [°C

]

100 %90 %80 %70 %60 %

50 %40 %30 %20 %10 %

e1heat recovery

0.9 kW

eR=e2 i1 heat recovery-0.9 kWi2

Supplydescription t [°C] rh [%]

e1 outdoor air 22.0 35eR heat recovery 25.3 29

Exhaustdescription t [°C] rh [%]

i1 extract air 26.0 50i2 heat recovery 22.7 61Note: AHU functions diagram. Inlet and outlet location may differ from actual position and port configuration.

e2 - supply air (SUP) i2 - exhaust air (EHA)

Dimensions:

Rechts Front View

Top View

LeftRight

K

i1

e2

e1

i2

R315

80

240

R315

80

418

R315

80

240

R315

80

283

830 370 x 275

140

150

2020

1270

KK

R315

210

418

R315

210

240

140

150

490

R315

210

240

R315

210

283

140

150

490

830 370 x 275

Weight = 187kg

Connections Type Diameter Accessoriese1 Outdoor Air ø 315 mm Shut off Damper,

Flexible Connectore2 Supply Air ø 315 mm Flexible Connectori1 Extract Air ø 315 mm Flexible Connectori2 Exhaust Air ø 315 mm Flexible ConnectorK Condensate Outlet ø 21 mm Condensate Trap

* The above figures are example performance measurements. Please use the Duplexvent Selection Software to calculate measurements at other performance levels.

9

Sound Insulation - Casing noise reduction:

Casing StrengthEN 1886, mm/m

10

4

0 1

D3

D2

D1

Energy EfficiencyEurovent

A

B

C

D

E

F

Hz dB125 38.3250 35.1500 39.1

1000 38.02000 36.14000 43.28000 46.0

Page 10: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

FLEXI DV2600

e,emax

i,imax

0500 1000 1500 2000 2500 3000 35000

200

400

600

800

1000

Exte

rnal

Sta

tic P

ress

ure

(Pa)

Performance Curve: Sound Parameters:Sound Power Level Lw (dB)

dB(A) 63 125 250 500 1 k 2 k 4 k 8 kOutdoor Air e1 45 60 58 46 36 33 29 <25 <25Supply Air e2 68 81 77 72 61 60 56 51 48Extract Air i1 44 59 58 45 35 32 28 <25 <25Exhaust Air i2Breakout Noise

67 81 77 71 60 59 55 50 4764 66 73 70 55 52 48 41 33

Sound Pressure Level Ld (dB)To the surroundings 43 45 53 49 34 32 28 <25 <25

Sound pressure level is measured at 3 m distance.

e, emax

i, imax

e, emax-Supply air (230 V), i, imax-Extract air (230 V)

Air Volume (m³/h)

Note: The figures above have been measured at 1400 m³/h and 200 Pa.

• Extracts up to 2600 m³/h (0.72 m³/s) @ 200 Pa• Excellent heat recovery efficiency, up to 95%• Versatile unit positioning with floor and ceiling suspended mounting options• Low SFP with energy saving EC fans• Low noise, refer to NR35 and BB93 standards• 10 speed digital control with Internet and BMS• Compliant to BREEAM, Passive House and

ErP 2013 / 2015 regulations

®

* The above figures are example performance measurements. Please use the Duplexvent Selection Software to calculate measurements at other performance levels.

10

Features

Performance

Ventilation:

m³/h (m³/s) Air Volume* 1400 (0.39) 1400 (0.39)External Static Pressure* Pa 200 200Nominal Voltage V 230 230Voltage (at operation point) V 230 230Nominal Power (at operation point)* W 305 271Max. Connection Power 870 870Max. Current A

W4.5 4.5F7 M5

Fan Type EC EC

Motors: e, i - Me.102 (230 V)

0500 1000 1500 2000 2500 3000 35000

200

400

600

800

1000

Nom

inal

Pow

er (W

)

e, i

Filters

Supply Air Extract Air 2600 (0.72 ) 2600 (0.72)Maximum Air Volume m³/h (m³/s)

Air Volume (m³/h)

Heat Recovery:

1400 (0.39) 1400 (0.39)Temperature at Inlet* °CAir Volume* m³/h (m³/s)

-10 22Temperature at Outlet* °C 17 1Humidity at Inlet* % rh 90 40Humidity at Outlet* % rh 12 100Thermal Efficiency in Winter (Summer) % 84 (81)Performance in Winter (Summer) kW 13.1 (-1.6)Condensation l/h 4.2

Counter Flow, Plastic

40500 1000 1500 2000 2500 3000 35000

50607080

10090

Ther

mal

Effi

cenc

y (%

)

---- Winter --- Summer

Type of Heat Exchanger

Air Volume (m³/h)

Supply Air Extract Air 2600 (0.72) 2600 (0.72)Maximum Air Volume m³/h (m³/s)

Page 11: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

FLEXI DV2600®

* The above figures are example performance measurements. Please use the Duplexvent Selection Software to calculate measurements at other performance levels.

11

e1 - outdoor air (ODA) i1 - extract air (ETA)e2 - supply air (SUP) i2 - exhaust air (EHA)

Summer Operation*:

230 V0.31 kW

S4.A.H81 %

-1.6 kW

filtration F7filtration F5

230 V0.27 kW

B

Me.102.EC1

Fe.K7Fi.K5

Mi.102.EC1

22 °C35 %22 °C

35 %

25 °C29 %

1400 m³/h200 Pa

26 °C28 %

1400 m³/h200 Pa

26 °C50 %

26 °C50 %

23 °C61 % 23 °C

59 %

outdoorair

e1

supplyair

e2

exhaustair

extractair

i1

i2

-5

0

5

10

15

2025

3035

4045

50

h [kJ/kg]

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15x [g/kg of dry air]

-15

-10

-5

0

5

10

15

20

25

30

t [°C

]

100 %90 %

80 %70 %60 %

50 %40 %30 %20 %10 %

e1heat recovery

1.6 kW

eR=e2 i1 heat recovery-1.6 kWi2

Supplydescription t [°C] rh [%]

e1 outdoor air 22.0 35eR heat recovery 25.2 29

Exhaustdescription t [°C] rh [%]

i1 extract air 26.0 50i2 heat recovery 22.8 61Note: AHU functions diagram. Inlet and outlet location may differ from actual position and port configuration.

Dimensions:

Rechts Front View

Top View

LeftRight 890 370 x 275

Weight = 226kg

Connections Type Diameter Accessoriese1 Outdoor Air 500 x 250 mm Shut off Damper,

Flexible Connectore2 Supply Air 500 x 250 mm Flexible Connectori1 Extract Air 500 x 250 mm Flexible Connectori2 Exhaust Air 500 x 250 mm Flexible ConnectorK Condensate

Outletø 21 mm Condensate Trap

K

i1

e2

e1

i2

500x

250

100

500x

250

160

500x

250

100

500x

250

160

890 370 x 275

140

150

2150

1570

KK

250

500

90

160

250

500

90

100

140

150

570

250

500

90

100

250

500

90

160

140

150

570

Sound Insulation - Casing noise reduction:

Casing StrengthEN 1886, mm/m

10

4

0 1

D3

D2

D1

Energy EfficiencyEurovent

A

B

C

D

E

F

Hz dB125 38.3250 35.1500 39.11000 38.02000 36.14000 43.28000 46.0

230 V0.31 kW

S4.A.H84 %

13.1 kW

filtration F7filtration F5

230 V0.27 kW

B

Me.102.EC1

Fe.K7Fi.K5

Mi.102.EC1

-10 °C90 %-10 °C

90 %

17 °C12 %

1400m³/h200 Pa

17 °C12 %

1400 m³/h200 Pa

22 °C40 %

22 °C40 %

1 °C100 % 2 °C

97 %

outdoorair

e1

supplyair

e2

exhaustair

extractair

i1

i2

-5

0

5

10

15

2025

3035

4045

50

h [kJ/kg]

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15x [g/kg of dry air]

-15

-10

-5

0

5

10

15

20

25

30

t [°C

]

100 % 90 % 80 % 70 % 60 %

50 %40 %30 %20 %10 %

e1

heat recovery13.1 kW

eR=e2

i1

heat recovery-13.1 kW

i2

Supplydescription t [°C] rh [%]

e1 outdoor air -10.0 90eR heat recovery 17.0 12

Exhaustdescription t [°C] rh [%]

i1 extract air 22.0 40i2 heat recovery 1.4 100

e1 - outdoor air (ODA) i1 - extract air (ETA)e2 - supply air (SUP) i2 - exhaust air (EHA)

Winter Operation*:

Note: AHU functions diagram. Inlet and outlet location may differ from actual position and port configuration.

Page 12: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

0500 1000 1500 2000 2500 3000 3500 40000

200

400

600

800

1000

1200

Exte

rnal

Sta

tic P

ress

ure

(Pa)

Performance Curve: Sound Parameters:Sound Power Level Lw (dB)

dB(A) 63 125 250 500 1 k 2 k 4 k 8 kOutdoor Air e1 50 67 65 46 39 35 28 <25 <25Supply Air e2 70 71 83 72 62 61 54 48 53Extract Air i1 50 66 65 45 38 34 28 <25 <25Exhaust Air i2Breakout Noise

69 69 82 71 61 59 53 47 5254 56 67 56 49 44 35 <25 <25

Sound Pressure Level Ld (dB)To the surroundings 33 36 46 36 28 <25 <25 <25 <25

Sound pressure level is measured at 3 m distance.

i, imax

e, emax-Supply air (400 V), i, imax-Extract air (400 V)

e, i

e, emax

Air Volume (m³/h)

Note: The figures above have been measured at 2000 m³/h and 250 Pa.

Ventilation:

2000 (0.56) 2000 (0.56)External Static Pressure* 250 250Nominal Voltage V

Pa400 400

Voltage (at operation point) VWW

400 400Nominal Power (at operation point)* 446 397Max. Connection Power 1480 1480Max. Current A 2.4 2.4

F7 M5Fan Type EC EC

Motors: e, i - Me.103 (400V)

0500 1000 1500 2000 2500 3000 3500 40000

250

500

750

1000

1250

1500

Nom

inal

Pow

er (W

)

e, i

Filters Air Volume (m³/h)

Supply Air Extract Air 3600 (1.00) 3600 (1.00)Maximum Air Volume m³/h (m³/s)

Air Volume* m³/h (m³/s)

Heat Recovery:

2000 (0.56) 2000 (0.56)Temperature at Inlet* °C -10 22Temperature at Outlet* °C 18 1Humidity at Inlet* % r h 90 40Humidity at Outlet* % r h 11 100Thermal Efficiency in Winter (Summer) % 88 (84)Performance in Winter (Summer) kW 19.4 (-2.3)Condensation l/h 6.5

Counter Flow, Plastic

40500 1000 1500 2000 2500 3000 3500 40000

50607080

10090

Ther

mal

Effi

cenc

y (%

)

---- Winter --- Summer

Type of Heat Exchanger

Air Volume (m³/h)

Supply Air Extract Air 3600 (1.00) 3600 (1.00)Maximum Air Volume m³/h (m³/s)

Air Volume* m³/h (m³/s)

airflow.com

FLEXI DV3600

• Extracts up to 3600 m³/h (1.00 m³/s) @ 200 Pa• Excellent heat recovery efficiency, up to 95%• Versatile unit positioning with floor and ceiling suspended mounting options• Low SFP with energy saving EC fans• Low noise, refer to NR35 and BB93 standards• 10 speed digital control with Internet and BMS • Compliant to BREEAM, Passive House and

ErP 2013 / 2015 regulations

®

* The above figures are example performance measurements. Please use the Duplexvent Selection Software to calculate measurements at other performance levels.

12

Features

Performance

Page 13: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

400 V0.45 kW

S4.A.H88 %

19.4 kW

filtration F7filtration F5

400 V0.40 kW

B

Me.103.EC3

Fe.K7Fi.K5

Mi.103.EC3

-10 °C90 %-10 °C

90 %

18 °C11 %

2000 m³/h250 Pa

19 °C11 %

2000 m³/h250 Pa

22 °C40 %

22 °C40 %

1 °C100 % 1 °C

97 %

outdoorair

e1

supplyair

e2

exhaustair

extractair

i1

i2

-5

0

5

10

15

2025

3035

4045

50

h [kJ/kg]

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15x [g/kg of dry air]

-15

-10

-5

0

5

10

15

20

25

30

t [°C

]

100 % 90 % 80 % 70 % 60 %

50 %40 %30 %20 %10 %

e1

heat recovery19.4 kW

eR=e2

i1

heat recovery-19.4 kW

i2

Supplydescription t [°C] rh [%]

e1 outdoor air -10.0 90eR heat recovery 18.1 11

Exhaustdescription t [°C] rh [%]

i1 extract air 22.0 40i2 heat recovery 0.8 100

e1 - outdoor air (ODA) i1 - extract air (ETA)e2 - supply air (SUP) i2 - exhaust air (EHA)

Winter Operation*:

Note: AHU functions diagram. Inlet and outlet location may differ from actual position and port configuration.

e1 - outdoor air (ODA) i1 - extract air (ETA)e2 - supply air (SUP) i2 - exhaust air (EHA)

Summer Operation*:

400 V0.45 kW

S4.A.H84 %

-2.3 kW

filtration F7filtration F5

400 V0.40 kW

B

Me.103.EC3

Fe.K7Fi.K5

Mi.103.EC3

22 °C35 %22 °C

35 %

25 °C29 %

2000 m³/h250 Pa

26 °C28 %

2000 m³/h250 Pa

26 °C50 %

26 °C50 %

23 °C61 % 23 °C

60 %

outdoorair

e1

supplyair

e2

exhaustair

extractair

i1

i2

-5

0

5

10

15

2025

3035

4045

50

h [kJ/kg]

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15x [g/kg of dry air]

-15

-10

-5

0

5

10

15

20

25

30

t [°C

]

100 %90 %80 %70 %60 %

50 %40 %30 %20 %10 %

e1heat recovery

2.3 kW

eR=e2 i1 heat recovery-2.3 kWi2

Supplydescription t [°C] rh [%]

e1 outdoor air 22.0 35eR heat recovery 25.3 29

Exhaustdescription t [°C] rh [%]

i1 extract air 26.0 50i2 heat recovery 22.6 61Note: AHU functions diagram. Inlet and outlet location may differ from actual position and port configuration.

Dimensions:

Rechts Front View

Top View

LeftRight 1040 370 x 275

Weight = 320kg

Connections Type Diameter Accessoriese1 Outdoor Air 600 x 300 mm Shut off Damper,

Flexible Connectore2 Supply Air 600 x 300 mm Flexible Connectori1 Extract Air 600 x 300 mm Flexible Connectori2 Exhaust Air 600 x 300 mm Flexible ConnectorK Condensate

Outletø 21 mm Condensate Trap

K

i1

e2

e1

i2

600x

300

75

600x

300

145

600x

300

75

600x

300

145

1040 370 x 275

140

150

2450

1660

KK

300

600

163

145

300

600

163

7514

0

150

780

300

600

163

75

300

600

163

145

140

150

780

airflow.com

FLEXI DV3600®

* The above figures are example performance measurements. Please use the Duplexvent Selection Software to calculate measurements at other performance levels.

13

Sound Insulation - Casing noise reduction:

Casing StrengthEN 1886, mm/m

10

4

0 1

D3

D2

D1

Energy EfficiencyEurovent

A

B

C

D

E

F

Hz dB125 38.3250 35.1500 39.1

1000 38.02000 36.14000 43.28000 46.0

Page 14: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

COMMERCIAL MULTI

ENGINEERED MULTI

airflow.com

MULTI®

• Innovative technology• 95% heat recovery efficiency• 100% custom designed• Highly compact for easy installation• Integrated heating and cooling• Vertical and horizontal mounting for wall or ceiling• Internet connectivity as standard

• Self diagnostic reduces service costs

• Smart phone application• Whole life cycle cost savings• BMS compatible• VDI 6022 hygiene certification

• Passive House Institute certification

• A family range, in excess of 30,000 m3/h air volume• EC fans using top quality German motors• Tough, durable insulated casing• Excellent thermal insulation TB1, T2• Latest counter flow heat exchanger• 100% by-pass for summer cooling• Circulation damper• Constant flow ensures optimum performance at all times

• Constant pressure regulation adjusts for effective ventilation rates

14

Page 15: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

Professional Solutions and Support

airflow.com

MULTI®

1. Innovation – Modern, attractive and practical styling, designed with ease of installation in mind. All components readily accessible inside the unit. . a co r ci c – Latest counter

flow heat exchanger technology enables exceptional thermal efficiency to reduce heating costs. 3. 100% Customisation – Multi units allow a complete bespoke configuration to suit your applications. Designers can configure spigot connections, filters, heating and cooling options to deliver required performance. 4. Extremely Compact – High Performance, Small Space. A major advantage of Multi Line is the ability to install within buildings with limited plant-room space. 5. Integrated Heating and Cooling – Self contained within the unit for ease of connection and servicing. 6. Versatile Positioning – Floor standing, ceiling suspended, vertical or horizontal, you can install Multi units virtually anywhere. Even on the roof with our weather-proof casing design.

7. BMS Compatible – Interface with leading protocols for effective communication with BMS.

8. Internet Connectivity – Included in standard units so no extra expense for remote monitoring. Via its built-in WEB SERVER Multi can be controlled and the system performance monitored continuously ensuring building operators are optimising energy savings and creating a healthy indoor environment. 9. Reduced Servicing – Real time monitoring ensures that changing conditions are identified and responded to curtailing the regularity of servicing and reducing running costs. 10. Smart Phone Application – Download the “App” for full monitoring and control by smart phone (compatible with iphone and Android). 11. VDI 6022 hygiene – Multi meets the stringent requirements of the internationally recognised VDI 6022 hygiene standard. They are suitable for specification in applications requiring a high level of air quality. 12. Passive House – Multi units certification by the Passive House Institute as a suitable component (pending). 13. BREEAM – The world’s leading design and assessment method for sustainable buildings. Multi helps meet the low energy ventilation assessments.

15

Page 16: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

As a ventilation specialist we aim to provide ventilation solutions for commercial applications thanks to our broad range of Commercial Heat Recovery units in excess of 30,000 m3/h air volume with the availability of indoor and outdoor versions. To accomplish this goal, our Passive House approved, ex-stock Flexi Line units provide the highest thermal efficiency with immediate delivery whilst our customised Multi Line units match your specification in terms of installation flexibility, performance and quality by meeting the high air volume requirements for commercial and large industrial spaces.

MULTI®

16

i i i o ra io

Horizontal(Maintenance access from the side)

Floor standing(Maintenance access from the top)

Ceiling suspended(Maintenance access from the bottom)

Upright(Maintenance access from the side)

Vertical(Maintenance access from the side)

• Heat Recovery Ventilation • 100% customisation• 95% thermal efficiency • Low energy EC plug fans • 10 speed digital control • Internet connection• Outdoor versions available

Features

Page 17: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

100% Bypass facility delivers cool, fresh and filtered air

Circulation damper helps regulate indoor temperature / humidity conditions

Built-in water / DX coils extra heating / cooling

1. Passive House Pack • Electric pre-heater to warm the incoming air

2. Constant Pressure Pack • Differential pressure and flow measurement for energy optimisation

3. Hygiene Pack • Inclined tube manometers to maintain the certified hygiene standard VDI 6022

Upgrade Packs

airflow.com

100% customisation and short delivery timeMulti Line MVHR units follow the business philosophy of multiple variability. Designers can easily modify unit positions, spigot connections, filters, integral heating / cooling coils, bypass and circulation dampers using the selection software which accelerates the specification process and helps meet stringent project requirements.

Despite the full customisation Multi Line units are delivered in a period of 4 weeks or earlier to meet tight project deadlines.

MULTI®

17

Page 18: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

G4 / M5 / F7 High Grade Filters provide ultra hygienic indoor climate and protect heat exchangers from getting dirty

G4 / M5 / F7 High Grade Filters provide ultra hygienic indoor climate and protect heat exchangers from getting dirty

Built-in heaters / coolers provide space saving solutionBuilt-in heaters / coolersprovide space saving solution

Smooth Internal Casing with 30mm insulation (class T2) avoids thermal bridging (class TB1), absorbs noise and meets sanitary standards

Smooth Internal Casing with 30mm insulation (class T2) avoids thermal bridging (class TB1), absorbs noise and meets sanitary standards

Lockable Large Access Doors simplify and accelerate the maintenance processLockable Large Access Doors simplify and accelerate the maintenance process

Condensate Drain for floor standing installationsCondensate Drain for floor standing installations

airflow.com

® MULTI

18

Page 19: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

Cross-Counter Flow Heat Exchanger up to 95% thermal efficiency reduce heating bills significantly and guarantee a quick return on investment

Cross-Counter Flow Heat Exchangerup to 95% thermal efficiency reduce heating bills significantly and guarantee a quick return on investment

Temperature Sensors for fully automatic operation of the summer bypass, frost protection and heater/cooler facilities

Temperature Sensorsfor fully automatic operation of the summer bypass, frost protection and heater/cooler facilities

100% Summer Bypass Facility provides a flow of cool, fresh and filtered air into the property

100% Summer Bypass Facility provides a flow of cool, fresh and filtered air into the property

Digital Control Box with internet and BMS connectionsDigital Control Box with internet and BMS connections

Circulation Damper for indoor temperature / humidity control

Circulation Damper for indoor temperature / humidity control

Low energy, maintenance free EC Fan Technology ensures long term savings on operating costs

Low energy, maintenance free EC Fan Technology ensures long term savingson operating costs

Pressure Sensors for filter monitoringPressure Sensors for filter monitoring

airflow.com

® MULTI

19

Page 20: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

® MULTI-N

20

2560 mm

2560 mm 2560 mm 2650 mm

2560 mm 2560 mm

DUPLEX 1500Multi-N

DUPLEX 5000Multi-N

DUPLEX 6500Multi-N

DUPLEX 8000Multi-N

DUPLEX 2500Multi-N

DUPLEX 3500Multi-N

1605

mm

1605

mm

1605

mm

1700

mm

1605

mm

1605

mm

555

mm

990

mm

1170

mm

1390

mm

685

mm

770

mm

READY FOR CRANE TRANSPORT

Ready for crane transport – special suspension points are included as standard for easy connection to a crane.

EASY MAINTENANCE

Multi-N Outdoor units are designed with continuous emphasis on service comfort.The units can be maintained via side access doors, without the need to open the unit doors.

EFFECTIVE INSTALLATION

DUPLEXVENT Multi-N Outdoor units can be ducted through the roof which is an excellent solution that saves material and labour costs in ducting and also significantly reduces the energy loss.

COMPACT SIZE

One of the biggest DUPLEXVENT Multi-N advantages is its compact size. Having an exceptionally low height, all units up to5000 m3/h are less than 1m high.

DUPLEXVENT MULTI-N OUTDOOR SIZE RANGE

The height dimension is for units only (without the 400 optional base frame)

Page 21: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com21

1

22

3 3

4 4

5

6

66

1. Base framewith 30 mm thick PIR insulation.2. Air ductswith no energy loss - duct and installation cost savings.

. a r i c a ito ensure maximum service comfort.

4. Riser ductfor condensate drainage.

5. Riser ductfor control system and heating / cooling pipes.

6. Side access doorsfor quick and easy maintenance.

Page 22: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

® MULTI

22

• Fully customised commercial units in 8 different sizes• Excellent heat recovery efficiency, up to 95%• Low SFP with energy saving EC fans• Low noise, refer to NR35 and BB93 standards• 10 speed digital control with Internet and BMS• Excellent thermal insulation (30mm) • Optional circulation and bypass dampers• BREEAM, EPDB and ErP 2013 / 2015 compliant

• Meets Building Regulations Part L2A and L2B

Features

Performance

1) 3) Maximum flow rate through units at zero external pressure Depending on equipment2) 4) According to air volume Depending on register type, liquid and �ow rates

D U P L E X M U L T I

DUPLEX Multi 500 1000 1500 2500 3500 5000 6500 80001)Supply air – max. 3 -1m h 660 1200 2200 3400 4600 5750 7100

1)Extraction air – max. 3 -1m h 670 1150 1800 3200 4200 5500 70502)Heat recovery efficiency % to 93 %

3)Weight kg 80 – 110 95 – 130 200 – 280 290 – 370 320 – 390 370 – 450 480 – 560Max. power input kW 0,3 0,7 1,2 2,6 4,5 4,6 7,3Voltage V 230 230 230 400 400 400 400Frequency Hz 50Revolutions – max. -1min 4300 3350 2920 3000 2980 2400 2820

4)Heating output T – max. kW 5 14 24 32 42 63 784)Cooling output CHW – max. kW 4 8 16 22 30 42 56

4)Cooling output CHF – max. kW 3 6 10 13 25 32 41

EC (backward curved impeller)

TBA

Fan type

Pres

sur e

res

erve

p (

Pa)

st

0 1000 2000 3000 90004000 5000 6000 7000

DU

PLEX 3500 Multi

M110

DUPLEX 5000 Multi

M111

DUPLEX 6500 M

ulti

M112

DU

PLEX 1500 M

ulti

M108

DU

PLEX 2500 Multi

M109

8000

DU

PLEX 500 Multi

M106

DU

PLEX 1000 M

ulti

M107200

400

500

700

600

1 000

800

0

900

300

100

3Air volume (m /h)

Supply section (G4)Supply section with T.3+CHW.5+G4Supply section with T.3+CHW.5+F7Exhaust section (G4)

P E R F O R M A N C E S U M M A R Y

A C O U S T I C P O W E R L A N D A C O U S T I C P R E S S U R E L W D 1

Type Working pointAcoustic power L [dB(A)]w Acoustic pressure L [dB(A)]D1

at distance of 1 minlet e1 inlet i1 outlet e2 outlet i2 unitDUPLEX 500 Multi 3500 m /h (200 Pa) 53 67 80 82 59 48DUPLEX 1000 Multi 31000 m /h (200 Pa) 66 65 86 86 63 52DUPLEX 1500 Multi 31500 m /h (200 Pa) 58 60 83 83 64 53DUPLEX 2500 Multi 32500 m /h (200 Pa) 59 55 80 79 70 59DUPLEX 3500 Multi 33500 m /h (200 Pa) 61 60 92 89 70 59DUPLEX 5000 Multi 35000 m /h (200 Pa) 64 65 88 88 73 62DUPLEX 6500 Multi 36500 m /h (200 Pa) 70 72 96 95 76 65DUPLEX 8000 Multi TBA

Page 23: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

® MULTI

23

1500 Multi

3500 Multi

5000 Multi 6500 Multi2500 Multi

500 Multi

1000 Multi

0 1000 2000 3000 90004000 5000 6000 7000 8000

Heat

rec

over

y ef

ficie

ncy

φ (%

)

H E A T R E C O V E R Y E F F I C I E N C Y

100

75

85

3Air volume (m /h)

90

70

80

95 for t = -15 °C , t = +20 °C , r h = 55 %, Mi = Mee1 i1 i1

for t = +5 °C, t = +2 5 °C, r h = 40 %, according to EN 308e1 i1 i1

CHW .5 (5-r ow) CHF .4 (4-r ow)

T.3 (3-r ow)

1500 Multi

2500 Multi 3500 Multi

5000 Multi6500 Multi

1000 Multi500 Multi

0 1000 2000 3000 90004000 5000 6000 7000 8000

H E A T I N G A N D C O O L I N G P E R F O R M A N C E S

20

80

40

100

60

Hea

ting

/ co

olin

g ca

paci

t y Q

(kW

)T/

CH

0

maximum heating capacity for T.3maximum cooling capacity for CHF.4 and CHW .5

3Air volume (m /h)

Max. heating capacity data T are valid f or 70/50 °C water temperature dropand +10 oCr.h. 10% supply air (after recovery) Max. cooling capacity data CHW are valid for 30 % water/ethylene-glycol mixture, 6/12 temperature drop, +30 °C, r.h. 50 % supply air

B A S I C D I M E N S I O N S

DUPLEX Multi 500 1000 1500 2500 3500 5000 6500 8000Dimension H mm 765 970 1600 1600 1600 1600 1600 1600Dimension B mm 384 384 455 580 665 885 1065 1290Length L mm 1600 1800 2300 2300 2300 2500 2500 2500Length L2 mm 1652 1852 2270 2270 2270 2470 2470 2470Condensate drain line mm Ø 22 Ø 32Connecting ports

1)Circular diameter D mm 200 250 315 – – – – –Dimension X1 x Y1 (standard e , i )1 1 mm – – – 300 x 400 400 x 400 500 x 500 500 x 500 700 x 500Dimension X2 x Y2 (atypical e , i )1 1 mm 2)200 2)250 400 x 200 300 x 400 400 x 400 500 x 500 500 x 500 –Dimension X3 x Y3 (standard e , i )2 2 mm – – – 450 x 710 500 x 710 710 x 710 900 x 710 900 x 710Dimension X4 x Y4 (atypical e , i )2 2 mm – – – 250 x 355 250 x 400 355 x 630 355 x 800 355 x 900

K K K

C B

405 x 305door

door

L

H20

010

0 X3 (Ø D)

B

Y3Y1

X1 (Ø D)

Y4

FLOOR -STANDING (front view)Multi 500 to 8000

alternative spigot position(configuration 11/10)

C B

UNDERCEILING (top view) Multi 500 to 6500

alternative spigot position(configuration 30/10)

1 65

0

L2

C B

alternative spigot position(configuration 41/10)

X1 (Ø D)

X4 (Ø D)

FLOOR -STANDING FLAT (top view)Multi 500 to 6500

Y2

X2 X2

door

alternative spigot position(configuration 30/5)

Y4

X4 (Ø D)door

Y4

X4 (Ø D)

Y4

X4 (Ø D)door

Y4

X4 (Ø D)

Y4

X4 (Ø D)

doorX3 (Ø D)

B

X1 (Ø D)

405 x 305L

H10

0Y2 Y2

X2 X2

door

Y2405 x 305L

H10

0

Y3Y1

Y3Y1

X3 (Ø D)

B

door

150

alternative spigot position(configuration 41/5)

1) 2) ... only for DUPLEX Multi 500, 1000, 1500 ... for DUPLEX Multi 500 and 1000 only in ceiling – suspended version

Page 24: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com24

® MULTI-N

• Fully customised outdoor units in 6 different sizes• Excellent heat recovery efficiency, up to 95%• Low SFP with energy saving EC fans• Ready for crane support• Side doors for filter change and maintenance works• Optional circulation and bypass dampers• 10 speed digital control with Internet and BMS• BREEAM, EPDB and ErP 2013 / 2015 compliant

• Meets Building Regulations Part L2A and L2B

Features

Performance

1) 3) Maximum flow rate through units at zero external pressure Depending on equipment2) 4) According to air volume Depending on register type, liquid and �ow rates

D U P L E X M U L T I - N

DUPLEX 1500 2500 3500 5000 6500 80001)Supply air – max. 3 -1m h 2500 3600 4700 5500 7200 8800

1)Extraction air – max. 3 -1m h 2300 3650 4600 5550 7100 89002)Heat recovery efficiency % to 93 %

Fan type3)Weight kg 290 – 350 350 – 480 405 – 480 460 – 560 520 – 630 630 – 750

Max. power input kW 1,5 2,5 4,4 4,1 6,7 8,9Voltage V 230 400 400 400 400 400Frequency Hz 50Revolutions -1min 2920 3000 2980 2420 2820 2570

4)Heating output T – max. kW 21 24 40 51 63 754)Cooling output CHW – max. kW 9 12 22 30 39 46

4)Cooling output CHF – max. kW 10 13 25 32 41 50

EC (backward curved impeller)

DU

PLEX 3500 Multi-N

M110

DUPLEX 5000 M

ulti-N

M111

DUPLEX 1

500 Multi-N

M108

DU

PLEX 2500 Multi-N

M109

200

400

500

700

600

1 000

800

0

900

300

100

Pres

sur e

re

ser v

e p

(Pa)

st

3Air volume (m /h)

Supply section (G4)Supply section with T.3+CHW .5+G4Supply section with T.3+CHW .5+F7Exhaust section (G4)

P E R F O R M A N C E S U M M A R Y

0 1 000 2 000 3 000 9 0004 000 5 000 6 000 7 000

DUPLEX 6500 M

ulti-N

M112

8 000

DUPLEX 8000 Multi-N

M113

A C O U S T I C P O W E R L A N D A C O U S T I C P R E S S U R E L W D 1

Type Working pointAcoustic power L [dB(A)]w Acoustic pressure L [dB(A)]D1

at distance of 1 minlet e1 inlet i1 outlet e2 outlet i2 unitDUPLEX 1500 Multi-N 31500 m /h (200 Pa) 57 57 87 88 61 50DUPLEX 2500 Multi-N 32500 m /h (200 Pa) 58 58 82 82 61 50DUPLEX 3500 Multi-N 33500 m /h (200 Pa) 59 59 87 88 59 48DUPLEX 5000 Multi-N 35000 m /h (200 Pa) 69 69 89 89 63 52DUPLEX 6500 Multi-N 36500 m /h (200 Pa) 73 73 95 95 66 55DUPLEX 8000 Multi-N 38000 m /h (200 Pa) 67 67 80 80 71 60

Page 25: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com25

® MULTI-N

1500 Multi-N 3500 Multi-N

5000 Multi-N

6500 Multi-N

2500 Multi-N

8000 Multi-N

0 1 000 2 000 3 000 9 0004 000 5 000 6 000 7 000 8 000

Heat

rec

over

y ef

ficie

ncy

φ (%

)

H E A T R E C O V E R Y E F F I C I E N C Y

100

75

85

3Air volume (m /h)

90

70

80

95 for t = -15 °C , t = +20 °C , r h = 55 %, Mi = Mee1 i1 i1

for t = +5 °C, t = +25 °C, r h = 40 %, according to EN 308e1 i1 i1

3Air volume (m /h)

1500 Multi-N

2500 Multi-N

3500 Multi-N

H E A T I N G A N D C O O L I N G P E R F O R M A N C E S

20

80

40

100

60

Hea

ting

/ co

olin

g ca

paci

t y Q

(kW

)T/

CH

0

5000 Multi-N6500 Multi-N

0 1 000 2 000 3 000 9 0004 000 5 000 6 000 7 000 8 000

8000 Multi-N

maximum heating capacity formaximum cooling capacity for CHF.4 and CHW .5

T.3

Max. heating capacity data T are valid f or 70/50 °C water temperature dropand +10 oCr.h. 10% supply air (after recovery) Max. cooling capacity data CHW are valid f30 % water/ethylene-glycol mixture, 6/12emperature drop, +30 °C, r.h. 50% supply airt

or

B A S I C D I M E N S I O N S

DUPLEX Multi-N 1500 2500 3500 5000 6500 8000Dimension H mm 1605 1605 1605 1605 1605 1700Dimension B mm 555 685 770 990 1170 1390Length L mm 2560 2560 2560 2560 2560 2650Dimension N mm 130 105 105 105 105 105Dimension P mm 135 105 105 105 105 105Dimension J mm 100 125 165 225 315 340Dimension M mm 155 160 205 265 355 350Condensate drain line mm Ø 32Connecting portsDimension X x Y mm 300 x 300 400 x 400 400 x 400 500 x 500 500 x 500 700 x 500Base frameDimension D mm 2500 2500 2500 2500 2500 2590Dimension F mm 1545 1545 1545 1545 1545 1640Dimension E mm 1228 1228 1228 1228 1228 1273Dimension G (between anchoring holes) mm 1505 1505 1505 1505 1505 1600Dimension S mm 795 595 595 395 395 490Dimension Q mm 400 300 300 200 200 278Dimension T mm 470 370 370 270 270 287

C B

Me Mi

K

L

Y

X x Y

B400

ROOFTOPconfiguration 4/1 6

K

GF

D

400

X x Y

BASE FRAME (optional accessorie)

duct

ext

ensi

on1

000

(X+100) x (Y+1 00)

EE 2222

For p

ositi

on 4

/ x

For p

ositi

on 3

/ x

HJ

MX

x Y

105 105

NX x Y P

X x

Y10

5

e2

X x Y

i1

X x Y

X

75

i1

X x Y

e2

X x Y

75

GF

DEE 2222

YY

95

Q75

YY

95X

T

B

S

Page 26: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

• Advanced control with digital display• 10 speed EC fan control

• Automatic bypass damper control for heat and cool recovery• Daily/Weekly programme setting

• Filter monitoring and alert via pressure sensors• BMS connection (Modbus, Konnex, BACnet) • Internet connection with user and service interfaces • Frost protection facility (preheater assisted)• Outputs for electric / water heater and DX / water cooler

• Zonal ventilation control (winter / summer) • Constant flow / pressure control

• Temperature control (extract or supply air) via 5 temperature sensors• Demand ventilation via CO2, humidity and air quality sensors

Duplexvent Commercial Heat Recovery units are delivered with a choice of manual or digital controls providing complete functionality of the units and their accessories.

Duplexvent units incorporate an Internet server that uses Modbus TCP / IP protocol to provide a connection between the ventilation unit and the internet via a standard plug & play ethernet cable.

This allows you to monitor and control the unit from a laptop via the internet or a local area network. The unit can also be monitored remotely by technical service which saves time and cost on service processes.

User Control / Service Monitoring

Building Management System (BMS)Demand Control via

CO2, rh%, Air Quality Sensors

User Control

®

airflow.com

Motion-Blue Control System

Internet Connection

Advanced Functionality and Control®

26

1st Floor

Page 27: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

Our advanced and user friendly Duplexvent Selection Software makes it possible to select the most suitableproduct in just a few simple steps.

This freely available online software* gives a quick survey of the right choice of product and easy access to relevant information regarding planning.

After having chosen the unit and accessories the user can select exactly what specification is needed for the project.

Technical specifications, air flow performance graphs, energy calculations, sound data and dimension drawings are all produced using the software.

®

Operation:• Input of technical parameters such as air volume, static pressure, temperature etc.

• Input of unit functions such as heating, cooling, air circulation, bypass etc.

• Automatic selection of the suitable ventilation unit

Software Outputs:

• Complete technical documentation including air path and HX diagrams

• Specification of the selected units and components with part numbers and prices

• Electrical wiring diagram with detailed information about supply voltage, rated current of the fans, fuses, cable connections etc.

• Data can be exported as doc, pdf or dxf (Autocad) format

• Product catalogue pages

Unit Construction:

• Selection of unit configuration and spigot positions for the specified installation

• Detailed dimensions of the ventilation unit including the spigot size and maintenance space

*The updated version of the selection software, which is updated every 6 months, can be found on our website www.airflow.com.

Selection Software ®

Quick and Easy Selection

27

Page 28: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

® Versatile Solutions

Our ventilation solutions are perfect for the following types of applications

Nursery

Large Residential Properties

Fitness Centres

Industrial Plants Public Areas

Retail

Restaurants

c

Typical Applications

28

Page 29: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

Accessories

Typical Installations

Versatile Solutions®

FLEXI DV2600

FLEXI DV3600

MULTI DV1500

MULTI DV2500N

MULTI DV6500

MULTI DV5000N

MULTI DV6500NMULTI DV3500N

MULTI DV1500N

To be fitted on the unit’s inlet port. They are supplied with a conventional servo drive having an emergency shut-off function

To be installed directly on the unit’s supply air spigots to heat the incoming air. For systems up to 110 °C and 1 MPa

To be installed directly on the unit’s supply air spigots to cool the incoming air. For systems up to 1 MPa

To be installed in either circular or rectangular ducts to temper up the temperature of the incoming air.

The same heater can be used either as preheater or post heater

To be used for precise volume and pressure control

To be used for the optimised control of the water heater and water cooler facilities

High grade G4, F5 and F7 to maintain the indoor air quality and protect the heat exchanger at all times

To be fitted on circular or rectangular spigots to ease the installation and avoid any duct vibration noises

Shut-off Dampers Flexible Connectors

Spare Filters

Control Manifolds Electric Heaters

Constant Flow Kits

Water / DX Coolers

Water Heaters

29

Page 30: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

airflow.com

The housing is manufactured from painted sheet metal incorporating up to 50mm thick polyurethane insulation (in accordance with EN1886) which improves the soundproof-ing of the unit and avoids thermal bridging. This also helps increase the unit's efficiency and hygienic standards (VDI 6022 certified).

Duplexvent units are equipped with ultra efficient, easily removable counterflow heat exchangers which transfer warmth from the outgoing waste airstream into the incoming fresh air and provide up to 95% thermal efficiency. At no time does the stale air mix with the fresh supply air unlike in rotary heat exchanger systems.

Low energy, maintenance-free EC fan technology ensures long life and lowest possible energy usage hence it reduces the energy consumption and the carbon footprint of the building.

To ensure a healthy indoor atmosphere at all times, Duplexvent units incorporate high grade F7 / M5 supply and exhaust air filters which also protect the heat exchanger against harmful particles hence increasing the interval between planned maintenance. The filter status is monitored by built-in pressure sensors in order to maintain ultra hygienic standards at all times.

The units also have a 100% summer bypass facility which is controlled automatically by temperature sensors to isolate the heat recovery function during the summer season. This helps to effectively cool the inside air without having to use expensive and energy hungry air conditioning systems.

The unique interchangeable spigot design allows the spigot connections to be changed on site (DV1600). Alternatively the positions of all spigot connections can be arbitrarily determined on Blue Line units. This will give installers the flexibility to connect the ducting to the unit from different directions which will reduce the number of duct connections and save on installation time.

HIGH QUALITY HOUSING UNIT

HIGHLY EFFICIENT HEAT EXCHANGERS

Premium Quality Components ®

ENERGY SAVING EC FAN TECHNOLOGY

INTERCHANGEABLE SPIGOTS

AUTOMATIC SUMMER BYPASS

HIGH GRADE FILTERS

30

Page 31: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

®

Why people choose Duplexvent Heat Recovery Units

airflow.com

Professional Solutions and Support®

We know how quickly experience and expertise can make a difference. As Airflow Developments, we have been providing solutions since 1955 and are experienced in all types of ventilation applications. Let our expertise make your job easier.

Our business is built on solid relationships. We work with you throughout your projectcommunicating and providing support as and when required.

Based on our engineering expertise and experience, we will provide you with technical telephone support to assist with your project. Our qualified team will help you with your selection and application from start to finish.

Submit your project and we will specify the correct equipment for your application. Alternatively let us train you to use our selection software.

Should you require our expertise, we will arrange for a technical sales engineer to visit you and guide you on your project. Also, once the project has been completed should further support be required, we are available.

Our products are built to a very high standard using high quality components enabling us to give a 5 year warranty*. You will get the best product for the best value.

Our quality products comply to ErP 2013/2015 and Building Regulations Part L2A/L2B requirements. They are also approved by TUV, certified by PassivHaus Institute and incorporate into BREEAM (SBEM) and EPDB assessments.

As a European manufacturer we understand the needs of our customers. Our design and product management team bring ideas that are functional, energy efficient and environmentally sound, so you can have the best products for your projects.

As an ISO 14001 accredited company we make every effort to respect the environment and do our utmost to ensure compliance with environmental legislation. Our ISO 9001 accreditation is a global acknowledgement of our ability to meet our customers' quality expectations. It also ensures our high standards and processes are maintained, benefitting our clients and reinforcing our position as a leading ventilation company.

*Excluding motors.

r i a i ci ca io

Free Technical Support

Technical Field Support

Comprehensive Warranty

r i ca io a ro a

Continuous Innovation

Environmental and Quality Accreditations

Commitment and Customer Care

Broad Experience and Expertise in Ventilation Industry

31

Page 32: Commercial Ventilation Solutions - Airflow Developments · PDF fileCommercial Ventilation Solutions FLEXI ... e,emax i,imax Ventilation: Air Volume* m³/h (m³/s) 500 (0.14) 500 (0.14)

80000101 - Issue 3 07/13

E-mail: [email protected]: +44 (0) 1494 525252 Facsimile +44 (0) 1494 461073

airflow.com

© Airflow Developments Limited. Airflow Developments Limited reserve the right, in the interests of continuous development, to alter specifications without prior notice. All orders are accepted subject to our conditions of sale which are available on request

irflow o m imiAidelle House, Lancaster Road,Cressex Business Park,High Wycombe, Buckinghamshire,HP12 3QP

a i i airflow.com

irflow i a io o io

I N T E R A C T I V E R A N G E

P R O F E S S I O N A L R A N G E

BASIC RANGE

RESIDENTIAL

CEILING

WALL

FLOOR / WALL

FLOOR / CEILING

BC300

DV110 SEDV90 SCKDV90 SEDV50 / DV80

DV180 EC4 DV370 EC4 DV510 EC4

DV150 SE / DV200 SE

NEW

NEWCEILING

BV300 BV400

NEW

BV400

®