COMMERCIAL, INDUSTRIAL AND ARCHITECTURAL SKYLIGHTS, HEAT AND SMOKE VENTS AND
SKYLIGHT FALL PROTECTION
Plasteco Acrylic, Polycarbonate/Glass Units and Structural Skylights
Would you like to add more natural light to your building? Brighten your space by adding skylights from Plasteco. Based in Houston and run by the same management team, Plasteco has been manufacturing and providing skylights across Texas since 1957. As Houston’s most trusted source for skylight engineering, manufacturing and installation, Plasteco provides the highest quality product in the industry, proven to withstand the test of time. Whether you want to add skylights to new construction or retrofit an existing skylight design, trust the professionals at Plasteco with all your skylight needs.
Daylighting with Plasteco Skylights
Daylight from skylights is free and is our coolest source of illumination, offering more light per unit of heat than any other source and providing about three times the amount of daylight as windows. Daylighting provided by skylights does not require the consumption of fuels and does not pollute the atmosphere. Skylights provide more lumens per BTU than artificial lighting. For the same lighting level, solar heat gain through dome skylights is one-eighth of incandescent lighting and one-half florescent lighting.
Daylighting with Unit Skylights
When daylighting using unit skylights, the best results are obtained with glazing that diffuses the transmitted light while lowering the solar energy transmitted through the glazing. Clear or tinted transparent glazing with smooth surfaces, regardless of the glazing material, does not diffuse the transmitted daylight. White translucent acrylic domes diffuse transmitted daylight while reducing the transmitted solar energy. This has been proven for more than 50 years.
OVER 50 YEARS OF INNOVATION & DESIGN
Install FallGuard® safety screens on your dome skylights and translucent panels on metal roofs. Skylights are not designed to support the weight of a human. OSHA requires all skylights have fall protection installed — it’s the law. With over 50 years of experience and a proven dedication to safety, trust the professionals at Plasteco for your skylight safety needs. While the information other skylight companies provide may say otherwise, skylights will not withstand a fall. Your own employees, contractors and passersby are all at risk for falling through your skylights. If your skylights don’t have safety screens, and someone falls, you are liable. FALLS ARE THE LEADING CAUSE OF DEATH IN CONSTRUCTION. In 2013†, there were 294 fall fatalities (284 falls to lower level) out of 796 total fatalities in construction. These deaths are preventable. By installing FallGuard®, you can help lower that statistic.
IT’S THE LAWSKYLIGHTS MUST BE PROTECTED.
CHOOSE FALLGUARD®: 1. The ORIGINAL skylight safety screens proven for more than 20 years
2. Eliminates the top deadliest accident — Falls
3. 100% Passive protection, no further action or training required
4. Cost-effective
5. Easy to install on existing skylights
6. A FallGuard® for all types and brands of skylight
INSTALL YOUR FALLGUARD® BEFORE IT’S TOO LATE.
36.9% RELATED TO FALLS IN 2013. Percentage of deaths in the construction industry
FallGuard® for Translucent Panels
FallGuard® for Dome Skylights
1992SINCE
Compliant
ACRYLIC Plasteco skylights may be ordered single-glazed or double-glazed and in the following acrylic colors:• clear colorless for maximum daylight and outside view • standard white translucent for excellent diffused light • bronze or gray transparent for sun and outside viewNote: Double dome skylights are subject to formation of condensate between domes. This may be objectionable when both are transparent. Typical Lighting Levels50 – 60 footcandles: classrooms, offices, drafting, merchandise, reading areas.25 – 30 footcandles: gymnasiums, lobbies, recreation rooms, libraries, machine shops, laboratories. 10 – 15 footcandles: corridors, stairways, warehouses, stockrooms, locker rooms, washrooms, kitchens, dining areas, baths.
TECHNICAL DATA
This table is based on a #4848 single dome of standard white translucent acrylic with 12" deep well and the conditions given below.Sky: 4000 footcandles Reflectance factors: Wells 60%, Ceiling 70%, Maintained Walls 50%, Floor 10%Notes: Adjust the 4000 footcandles to suit average local condition. Larger skylights are more efficient; deeper wells are less efficient.
All figures are average, and may vary with thickness of sheet. Double-glazed coefficient is based on gray/bronze outer dome, colorless inner dome. ¼" air space. *These colors are normally carried in stock.
GLASSCertain Plasteco models are available with insulated glass. The outer glass can be either clear or bronze while the inner glass is laminated safety glass. Plasteco should be consulted early in the planning stages to determine whether we can meet your design requirements with insulated glass. ALUMINUM FRAME FINISHESAnodic finishes are available in clear (natural) or integral color coatings of light, medium or dark bronze. Typical trade name for integral color coatings are Duranodic and Kalcolor. Color matching is sometimes difficult with these finishes.Paint finishes are available in a wide range of colors. Select either baked-on powder coat paint or fluoropolymer finish.Mill finish is standard and will be furnished by Plasteco unless another finish is specified. TECHNICAL ASSISTANCEPlasteco offers technical assistance on all its products. Consultation is especially advisable when planning custom or structural skylights. Plasteco reserves the right to make design improvements without notice. RESPONSIBILITYPlasteco is responsible for furnishing skylight to fit specified outside curb dimensions or roof opening dimensions. It is the responsibility of others, however, to assure the integrity, strength and dimensional accuracy of the supporting structure — factors which are essential to a successful installation. GENERAL INFORMATIONCondensation: Since acrylic domes cannot be hermetically sealed, condensation may form between domes. In most instances, the condensation is temporary. Noise: In some installations a "popping" noise may be heard. For example, when a passing cloud covers a tinted dome which was in direct sunlight, the dome may suddenly contract.Design: Plasteco, Inc. reserves the right to make design changes without notice. Any design changes will be presented on approval drawings.Safety: Plasteco, Inc. skylights are not designed to support body weight. Further information on FallGuard® Skylight Screens fall protection is available in this brochure.
Acrylic ColorTransmittance Shading Coefficient
Visible Light Solar Energy Single-Glazed Double-Glazed
*Colorless 92% 89% 0.98 0.89
*STD White (1/8") 52% 52% 0.45 0.41
2064 Gray 27% 35% 0.53 0.43
2537 Gray 33% 41% 0.59 0.49
2094 Gray 45% 55% 0.71 0.61
2514 Gray 59% 62% 0.78 0.68
2370 Bronze 10% 20% 0.40 0.30
*2412 Bronze 27% 35% 0.53 0.43
2404 Bronze 49% 56% 0.72 0.62
2539 Bronze 61% 62% 0.78 0.68
Ratio Building Width to Ceiling Height
Percent of Roof Area to be Skylighted
15fc 30fc 60fc
1.0 3.0% 6.0% 9.0%
1.25 2.5 5.0 7.5
1.50 2.2 4.4 6.6
2.0 1.8 3.6 5.4
3.0-5.0 1.6-1.4 3.2-2.8 4.8-4.2
6.0 & over 1.3 2.6 3.9
U-values – BTU/hr/sq ft/°F
16" AcrylicWinter Heat Loss
15 mph windSummer Heat Gain
7 1/2 mph wind
Single-Glazed 1.2 0.8
Double-Glazed 0.7 0.5
1 U-value2 Shading
Coefficient3 Visible Light Transmission
4 UV Transmission
Flammability Rating
Acrylic
3/16 Single 1.2
.98 to .10 .92 to .10
— cc/2Greater impact resistance than glass and more
cost efficient. Facilitates open design.3/16 Double 0.7 — cc/2
Triple 0.3 — cc/2
Polycarbonate (monolithic)
3/16 Single 1.2
.98 to .10 .92 to .10
— cc/1Greater impact resistance than acrylic.
Less costly than glass.3/16 Double 0.7 — cc/1
Triple 0.3 — cc/1
Glass
Single 1.15
1.00 to .10 1.00 to .10 .80 to .12
cc/1 Traditional beauty, UV stable, good U-values. Public safety & building codes are important
concerns when specifying glass. More expensive than other media.
Double 0.56 cc/1
Triple 0.37 cc/1
Structured Sheet (Polycarbonate)
6 mm 0.63
1.00 to .94 .82 to .20
0 cc/1
Excellent U-values. Cost efficient. Durable. Easy installation.
8 mm 0.60 0 cc/1
10 mm 0.53 0 cc/1
16 mm 0.41 0 cc/1
25 mm 0.31 0 cc/1
GLAZING MEDIA SELECTION
MEDIA SELECTION CHARTWelcome to the industry’s broadest range of glazing media choices. Review the Media Selection Chart and you’ll get a head start on putting the power of Plasteco’s design flexibility behind your project. Plasteco skylights are designed to accommodate monolithic glazing, structured sheet and glass. For detailed assistance, contact your Plasteco representative.
Notes: 1. U-value is the heat-transfer rate through materials, measured in BTU/hr/sq ft/°F temperature difference. Winter nighttime U-values are calculated assuming an outdoor temperature of 0°F, an indoor temperature of 70°F and a wind velocity of 15 mph.
2. Shading coefficient compares the total solar heat gain through any other glazing with that through a single pane of 1/8" glass — which has a shading coefficient of 1.
3. Visible light transmission indicated the percentage of the visible spectrum that passes through the glazing.
4. UV (ultraviolet) transmission is given because the sun’s shortwave UV energy afades fabrics.
3
UNIT SKYLIGHTS
MODELS 100 & 101 MODEL 197 THERMAL BREAK
MODELS 208 & 209 MODEL 297 THERMAL BREAK
Specifications: Dome Skylights shall be factory assembled as manufactured by Plasteco, Inc., Houston, Texas (713.673.7710; Fax 713.673.7236). It shall consist of a skylight mounted on a 9" high insulated double wall aluminum curb. The insulation shall be 1-1/2" thick polyisocyanurate. Dome shall be formed of (clear, white translucent or bronze) acrylic to support a uniform 40 psf load. (For Model 209, add: Inner dome shall be formed of (clear or white translucent) acrylic.)
Add alternate: Fall protection as required by OSHA Regulation 1926.501 “Duty to Have Fall Protection” shall be provided by Model A FallGuard® Skylight Screens. FallGuard® Skylight Screens shall be shipped separately and installed prior to the installation of the skylight.
Specifications: Dome Skylights shall be factory assembled as manufactured by Plasteco, Inc., Houston, Texas (713.673.7710; Fax 713.673.7236). Each unit shall have an inner frame (.072") and an outer frame (.055") of 6063-T5 extruded aluminum. Inner frame shall have a 6° sloping condensation gutter with weepage, a dome elevating leg with continuous EPDM gasket. Dome shall be formed of (clear, white translucent or bronze) acrylic to support a uniform 40 psf load. (For Model 101, add: Inner dome shall be formed of (clear or white translucent) acrylic.)
4
STANDARD SKYLIGHT SIZES (custom sizes also available)
Dome Curb Mount Pyramid Curb MountDouble Wall Self-
Flashing Insulated 9" Curb
Thermalized Curb Mount
Thermalized Self-Flashing Insulated
Curb
OSHA Required FallGuard® Skylight
Screen
Model Single Glaze 100 120 208 — — ASM-1
Model Double Glaze 101 121 209 197 297 ASM-1
— — Add “P” for Pyramid —
Square Rectangular
Inside Curb Dimension Outside Curb Dimension Inside Curb Dimension Outside Curb Dimension
2424 22 ¼" x 22 ¼" 25 ½" x 25 ½" 2448 22 ¼" x 46 ¼" 25 ½" x 49 ½"
3232 30 ¼" x 30 ¼" 33 ½" x 33 ½" 3248 30 ¼" x 46 ¼" 33 ½" x 49 ½"
3939 37" x 37" 40 ¼" x 40 ¼" 3272 30 ¼" x 69 ½" 33 ½" x 72 ¾"
4848 46 ¼" x 46 ¼" 49 ½" x 49 ½" 4872 46 ¼" x 69 ½" 49 ½" x 72 ¾"
5858 55" x 55" 58 ¼" x 58 ¼" 4892 46 ¼" x 89 ½" 49 ½" x 92 ¾"
7272 69 ½" x 69 ½" 72 ¾" x 72 ¾" 6072 57 ¼" x 69 ½" 60 ¾" x 72 ¾"
7777 75" x 75" 78 ¼" x 78 ¼" 6092 57 ¼" x 89 ½" 60 ¾" x 92 ¾"
9494 92 ½" x 92 ½" 95 ¾" x 95 ¾" — — —
TYPCAL SECTION
ROOF MEMBRANE ORFLASHING (NOT BY
PLASTECO)
WOOD CURB(NOT BY PLASTECO)
OUTER FRAMEW/#10 x 1/2"HWHSDS AT
18" O.C.
#10 X 2"HHSMSAT 15" O.C.
(NOT BYPLASTECO)
OUTSIDE CURB DIMENSION
INNER FRAMEEXTRUDED ALUMINUM
1 1/2" MIN.CURB THICKNESS
4" MIN TO TOP OFCAT STRIP6" MIN TO ROOF LINE
SINGLE GLAZE(MODEL 100)
INNER GLAZE(MODEL 101)
WEEP HOLES
FALLGUARD SKYLIGHT SCREEN(PATEN NO. 5,237,788)
(SEE SPEC- ADD ALTERNATE)
FALLGUARD RAIL(OPTIONAL)
TYPCAL SECTION
ROOF MEMBRANE ORFLASHING (NOT BY
PLASTECO)
OUTER FRAMEW/#10 x 1/2"HWHSDS AT
18" O.C.
#10 X 2"HHSMSAT 15" O.C.
(NOT BYPLASTECO)
FALLGUARD SKYLIGHT SCREEN(PATEN NO. 5,237,788)
(SEE SPEC- ADD ALTERNATE)
INNER FRAMEEXTRUDED ALUMINUM
4" MIN TO TOP OFCAT STRIP6" MIN TO ROOF LINE
FALLGUARD RAIL(OPTIONAL)
3"
INSULATED CURB(9" OR 12")
WOOD NAILER(OPTIONAL)
ALUM. LINERMIN. 0.040"
ALUM. OUTERMIN. 0.040"
WEEP HOLES
SINGLE GLAZE(MODEL 208)
INNER GLAZE(MODEL 209)
TYPCAL SECTION
ROOF MEMBRANE ORFLASHING (NOT BY
PLASTECO)
3"
INSULATED CURB(9" OR 12")
WOOD NAILER(OPTIONAL)
ALUM. LINERMIN. 0.040"
ALUM. OUTERMIN. 0.040"
FALLGUARD SKYLIGHT SCREEN(PATEN NO. 5,237,788)
(SEE SPEC-ADD ALTERNATE)
DOUBLE GLAZE(MODEL 297)
#10 X 2"HHSMSAT 15" O.C.
(NOT BYPLASTECO)
FALLGUARD RAIL(OPTIONAL)
TYPCAL SECTION
INNER FRAMETHERMAL BREAK
ACRYLIC GLAZING(DOMES OR PYRAMIDS)RAIL
(Optional)GUARDFALL
#10 X 2"HHSMSAT 15" O.C.
(NOT BYPLASTECO)
OUTSIDE CURB DIM.1 1
2"
FALLGUARD SKYLIGHT SCREEN(PATEN NO. 5,237,788)
(SEE SPEC- ADD ALTERNATE)
MODEL 197 THERMAL BREAK
MODEL 297 THERMAL BREAK
Models 204 & 205
Inner Frame Dimension Inside Bottom Curb
2424 22 7/8" x 22 7/8" 24 1/2" x 24 1/2"
3232 30 7/8" x 30 7/8" 32 1/2" x 32 1/2"
3939 37 5/8" x 37 5/8" 39 1/4" x 39 1/4"
4848 46 7/8" x 46 7/8" 48 1/2" x 48 1/2"
5858 55 5/8" x 55 5/8" 57 1/4" x 57 1/4"
7272 70 1/8" x 70 1/8" 71 3/4" x 71 3/4"
7777 75 5/8" x 75 5/8" 77 1/4" x 77 1/4"
9494 93 1/8" x 93 1/8" 94 3/4" x 94 3/4"
2448 22 7/8" x 46 7/8" 24 1/2" x 48 1/2"
3248 30 7/8" x 46 7/8" 32 1/2" x 48 1/2"
3272 30 7/8" x 70 1/8" 32 1/2" x 71 3/4"
4872 46 7/8" x 70 1/8" 48 1/2" x 71 3/4"
4892 46 7/8" x 90 1/8" 48 1/2" x 91 3/4"
6072 58 1/8" x 70 1/8" 59 3/4" x 71 3/4"
6092 58 1/8" x 90 1/8" 59 3/4" x 91 3/4"
Specifications: Circular Skylights shall be factory-assembled Plasteco Model 802 (or 803). Each unit shall have a .050" thick aluminum integral curb and an extruded aluminum outer frame. Dome shall be formed of (color) acrylic. (For double-glazed models add: Inner dome shall be (white or clear) acrylic.)
Add alternate: Provide fall protection as required by OSHA regulation 1926.501 “Duty to Have Fall Protection.”
4" High Curb 9" High Curb
Single Dome
Double Dome Dia. A Dome
HeightSingle Dome
Double Dome
800-36 801-36 31 8 802-36 803-36
800-48 801-48 43 11 802-48 803-48
800-60 801-60 54 15 802-60 803-60
800-72 801-72 67 17 802-72 803-72
800-84 801-84 79 20 802-84 803-84
800-96 801-96 91 22 802-96 803-96
MODELS 800, 801, 802 & 803CIRCULAR 4" & 9" INSULATED CURB SKYLIGHTS
5
NON-INSULATING ALUMINUM MODELS 204 & 205
3"
4"
9" o
r 12"
1"
SINGLE GLAZE(MODEL 800 & 802)
INSULATION
ROOF OPENING
INNER GLAZE(MODEL 801 & 803)
ALUMINUM CURB
FALLGUARD SKYLIGHT SCREEN(PATEN NO. 5,237,788)
(SEE SPEC- ADD ALTERNATE)
OUTER FRAMEEXTRUDEDALUMINUM
FALLGUARD RAIL(OPTIONAL)
FALLGUARD(OPTIONAL)
OUTER FRAME (AC177)ATTACH W/ #10 X 1/2"HWHSDS AT 18" O.C.
INNER FRAME (AC178) W/ WEEPHOLES IN DOME ELEVATING LEG
ROOF MEMBRANE OR FLASHING(NOT BY PLASTECO)
1/4" DIA. HOLES AT 18" O.C.
ACRYLIC GLAZING (DOMES)SET ON SANTOPRENEGASKET (GC190)
INNER FRAME DIM.
INSIDE BOTTOM CURB DIM.
TYPICAL SECTION
ALSO AVAILABLE WITH THERMAL BREAK DESIGN
Plasteco’s Continuous Vaulted Skylight Model 300 (single-glazed) and Model 301 (double-glazed) are available in widths ranging from 2'-6" to 7' with unlimited length. They are composed of pre-assembled half dome or vertical ends and intermediate sections which are shipped K-D. The intermediate sections consist of flat, acrylic, monolithic polycarbonate, or structured sheet polycarbonate sheets cold formed over pre-formed aluminum arches.
The curb frame comes with a self-adjusting counter-flashing to reduce the amount of air infiltration (or exfiltration) that occurs between the top of the curb and the skylight curb frame.
These skylights are light in weight and provide an economical solution to daylighting of relatively large rectangular areas. Since the skylight opening is rectangular, the construction of the structural framing, curbs, roofing, flashing and the interior finish is simplified resulting in a lower completed cost.
Although the skylights are normally furnished K-D (except for the ends), Plasteco has shipped pre-assembled 20' sections. The pre-assembled 20' sections have special designed ends that can be mulled together with a special EPDM gasket. Projects consisting of 20,000' have been installed using the 20' pre-assembled sections.
Since skylights are not designed to support body weight, some method of fall protection should be provided. See add alternate for information on OSHA regulations on fall protection.
INNER ACRYLIC(MODEL 301)
OUTER ACRYLIC(MODEL 300)
1 1/2"CURB THICKNESS
DIMENSION A
CURB FRAMEEXTRUDED ALUMINUM
SELF-ADJUSTINGCOUNTER-FLASHING
CURB & ROOFINGBY OTHERS
1 1/2"CURB THICKNESS SELF-ADJUSTING
COUNTER-FLASHING
CURB FRAMEEXTRUDED ALUMINUM
INNER ACRYLIC(MODEL 301)
OUTER ACRYLIC(MODEL 300)
CURB BY OTHERS
Specifications: Continuous Vaulted Skylights shall be single-glazed Model 300 (double-glazed Model 301) as manufactured by Plasteco, Inc. (713.673.7710; Fax 713.673.7236). Curb (by others) shall have a minimum thickness of 1-1/2". Each skylight shall consist of a pair of pre-assembled half domes (or vertical ends). The intermediate sections are shipped K-D with arch sections over nominal 4' spacing. Model 300 acrylic shall be clear, bronze or #2447 white translucent. Model 301 inner acrylic shall be clear or white translucent.
Curb frame, inner and outer arch supports shall be 6063-T5 extruded aluminum. Exterior exposed aluminum can be mill finish, clear anodized, bronze anodized, and powder coating or flouropolymer (color). Curb frame shall have self-adjusting counter-flashing. All gaskets shall be black EPDM. Skylights are designed to support a 20 psf load.
Add alternate: Fall protection as required by OSHA Regulation 1926.501 “Duty to Have Fall Protection” shall be provided by Model A FallGuard® Skylight Screens. FallGuard® Skylight Screens shall be shipped separately.
Single-Glazed Model 300
Double-Glazed Model 301 Dome Ht. Outside Curb
Dim. A
300-30
300-36
300-42
301-30
301-36
301-42
7"
8"
9"
33 ¼"
39 ¼"
45 ¼"
300-48
300-54
300-60
301-48
301-54
301-60
10"
11"
12"
51 ¼"
57 ¼"
63 ¼"
300-72
300-84
301-72
301-84
14"
16"
75 ¼"
87 ¼"
Add TB to Model Number for Thermal Break Design
CONTINUOUS VAULTED SKYLIGHTS (custom sizes also available)
CONTINUOUS VAULTED SKYLIGHTS
CURB
DOMED END
STAINLESSSTEEL SCREW
MODEL 300
INNER ARCH
ACRYLICGASKET
STAINLESSSTEEL SCREW
ACRYLIC
INNER ARCH
INNER ACRYLIC
MODEL 301
GASKET
1
2
12
3
ARCH3
6
ALSO AVAILABLE WITH THERMAL BREAK DESIGN
Plasteco’s Structural Barrel Vault Skylights provide an economical and practical means of presenting daylight and spaciousness to a lobby, atrium or the interior of a building. They have also been used as entrance canopies, walkway canopies and as a cover between adjacent buildings. They are available in widths from 8' to 24' with unlimited lengths, single- or double-glazed. The curved aluminum rafters and acrylic, monolithic polycarbonate, or structural sheet polycarbonate glazing combination results in a lightweight, economical skylight.
Since the skylight opening is rectangular, the construction of the structural framing, curbs, roofing, flashing and the interior finishing is simplified, resulting in a lower completed cost. Skylights are not designed to support body weight, and some method of fall protection should be provided. See “add alternate” for information on OSHA regulations on fall protection.
STRUCTURAL BARREL VAULTS (custom sizes also available)
Single-Glazed Double-Glazed Outside Curb Dim. A Dome Ht.
310-8
310-10
310-12
310-16
310-20
310-24
311-8
311-10
311-12
311-16
311-20
311-24
8'-0"
10'-0"
12'-0"
16'-0"
20'-0"
24'-0"
1'-5 1/2"
1'-10"
2'-2"
2'-11"
3'-8"
4'-4 1/2"
Add TB to Model Number for Thermal Break Design
STRUCTURAL BARREL VAULT SKYLIGHTS
5
1
3
RAFTER3
CURB1
PURLIN5
HALF ROUND VAULTS (custom sizes also available)
Single-Glazed Double-Glazed Outside Curb Dim. A Dome Ht.
312-6
312-8
312-10
312-12
312-16
313-6
313-8
313-10
313-12
313-16
6'-0"
8'-0"
10'-0"
12'-0"
16'-0"
3'-0"
4'-0"
5'-0"
6'-0"
8'-0"Standard End Pattern
(sunburst pattern is a custom end)
Specifications: Structural Half Round Vault Skylights shall be as manufactured by Plasteco, Inc., Houston, Texas (713.673.7710; Fax 713.673.7236). All extruded aluminum shall be 6063-T5. Exterior exposed aluminum can be mill finish, (clear anodized, bronze anodized, and power coating or flouropolymer (color)). Model 312 outer acrylic can be clear, (2412 bronze, or 2447 white translucent). Model 313 inner acrylic can be clear, (or 2447 white translucent). Rafters shall be mounted on nominal 4' centers. The skylight shall be designed to support 20 psf live load and a 20 psf wind load. Curbs (by others) shall have a minimum thickness of 5-1/2" and shall be designed to support the skylight and thrust of a 20 psf live load.
Add alternate: Fall protection as required by OSHA Regulation 1926.501 “Duty to Have Fall Protection” shall be provided by Model A FallGuard® Skylight Screens. FallGuard® Skylight Screens shall be shipped separately and installed prior to the installation of the skylight.
5
1
3
7
CLAMP BAR
PURLIN TUBE
GLAZING MULLIONARCH TUBE
GLAZING MULLION
OUTER GASKET (GC064) CLAMP BAR
2" X 2" X 3/16" ARCH TUBE
WET SEALED
CL
SECTION AT PURLINSECTION AT RAFTER
ROOF MEMBRANE
1/4-20 1.3/4" HHSTS
@ 18" O.C.WEEP SLOTS
@ 18" O.C.
(BY OTHERS)(2) 2 X 4 WOOD
OUTSIDE CURB DIMENSION
RAFTER TUBE
ANCHOR BOLT
CURB FLASHING( NOT BY PLASTECO)
1 3/16"
5 12" MIN CURB THICKNESS
INNER GLAZE
ACRYLIC
(MODEL 311)
ACRYLIC GLAZING
GLAZING MULLION
MULLION COVER
ARCH TUBE
LC
SECTION AT SINGLE GLAZE RAFTER (MODEL 310)
OUTER GLAZE
INNER GLAZE
OUTER GLAZE
INNER GLAZE
SANTOPRENE GASKET
SANTOPRENE GASKET
SECTION AT STANDARD VAULTED SILL
CLAMP BAR
PURLIN TUBE
GLAZING MULLIONARCH TUBE
GLAZING MULLION
OUTER GASKET (GC064) CLAMP BAR
2" X 2" X 3/16" ARCH TUBE
WET SEALED
CL
SECTION AT PURLINSECTION AT RAFTER
ROOF MEMBRANE
1/4-20 1.3/4" HHSTS
@ 18" O.C.WEEP SLOTS
@ 18" O.C.
(BY OTHERS)(2) 2 X 4 WOOD
OUTSIDE CURB DIMENSION
RAFTER TUBE
ANCHOR BOLT
CURB FLASHING( NOT BY PLASTECO)
1 3/16"
5 12" MIN CURB THICKNESS
INNER GLAZE
ACRYLIC
(MODEL 311)
ACRYLIC GLAZING
GLAZING MULLION
MULLION COVER
ARCH TUBE
LC
SECTION AT SINGLE GLAZE RAFTER (MODEL 310)
OUTER GLAZE
INNER GLAZE
OUTER GLAZE
INNER GLAZE
SANTOPRENE GASKET
SANTOPRENE GASKET
SECTION AT STANDARD VAULTED SILL
CLAMP BAR
PURLIN TUBE
GLAZING MULLIONARCH TUBE
GLAZING MULLION
OUTER GASKET (GC064) CLAMP BAR
2" X 2" X 3/16" ARCH TUBE
WET SEALED
CL
SECTION AT PURLINSECTION AT RAFTER
ROOF MEMBRANE
1/4-20 1.3/4" HHSTS
@ 18" O.C.WEEP SLOTS
@ 18" O.C.
(BY OTHERS)(2) 2 X 4 WOOD
OUTSIDE CURB DIMENSION
RAFTER TUBE
ANCHOR BOLT
CURB FLASHING( NOT BY PLASTECO)
1 3/16"
5 12" MIN CURB THICKNESS
INNER GLAZE
ACRYLIC
(MODEL 311)
ACRYLIC GLAZING
GLAZING MULLION
MULLION COVER
ARCH TUBE
LC
SECTION AT SINGLE GLAZE RAFTER (MODEL 310)
OUTER GLAZE
INNER GLAZE
OUTER GLAZE
INNER GLAZE
SANTOPRENE GASKET
SANTOPRENE GASKET
SECTION AT STANDARD VAULTED SILL
CLAMP BAR
PURLIN TUBE
GLAZING MULLIONARCH TUBE
GLAZING MULLION
OUTER GASKET (GC064) CLAMP BAR
2" X 2" X 3/16" ARCH TUBE
WET SEALED
CL
SECTION AT PURLINSECTION AT RAFTER
ROOF MEMBRANE
1/4-20 1.3/4" HHSTS
@ 18" O.C.WEEP SLOTS
@ 18" O.C.
(BY OTHERS)(2) 2 X 4 WOOD
OUTSIDE CURB DIMENSION
RAFTER TUBE
ANCHOR BOLT
CURB FLASHING( NOT BY PLASTECO)
1 3/16"
5 12" MIN CURB THICKNESS
INNER GLAZE
ACRYLIC
(MODEL 311)
ACRYLIC GLAZING
GLAZING MULLION
MULLION COVER
ARCH TUBE
LC
SECTION AT SINGLE GLAZE RAFTER (MODEL 310)
OUTER GLAZE
INNER GLAZE
OUTER GLAZE
INNER GLAZE
SANTOPRENE GASKET
SANTOPRENE GASKET
SECTION AT STANDARD VAULTED SILL
8
STRUCTURAL RIDGES
Specifications: Structural Ridge Skylights shall be as manufactured by Plasteco, Inc., Houston, Texas (713.673.7710; Fax 713.673.7236). Manufacturer shall furnish a complete K-D structural framing consisting of curb rail, of 6063-T5 mill finish (anodized, bronze hardcoat or painted finish also available) extruded aluminum or field assembly by others to support a minimum load of 20 psf. Units shall be furnished mounted in a 6063-T5 extruded aluminum frame (specify finish). Glazing to be as specified by architect.
Curbs shall be furnished by others to Plasteco’s dimension. Structural integrity of curb and supporting structure is responsibility of architect/engineer. Curbs to be flashed by others. Skylight shall have an integral system of condensation gutters with drainage to exterior. Weepholes shall not be exposed to view and shall have a buffer type air cover.
STRUCTURAL RIDGE & PYRAMID SKYLIGHTS
Hipped Ends
Single-Glazed Double-Glazed Outside Curb Dimension A Height
180-12 181-12 12' 2'-6"
180-16 181-16 16' 3'-4"
180-20 181-20 20' 4'-2"
GLAZING: Acrylic; Monolithic & Structured Sheet Polycarbonate
Gabled Ends
Single-Glazed Double-Glazed Outside Curb Dimension A Height
182-12 183-12 12' 2'-6"
182-16 183-16 16' 3'-4"
182-20 183-20 20' 4'-2"
Hipped Ends
Laminated Insulated Outside Curb Dimension A Height
184-12 185-12 12' 2'-6"
184-16 185-16 16' 3'-4"
184-20 185-20 20' 4'-2"
GLAZING: Glass
Gabled Ends
Laminated Insulated Outside Curb Dimension A Height
186-12 187-12 12' 2'-6"
186-16 187-16 16' 3'-4"
186-20 187-20 20' 4'-2"
STRUCTURAL RIDGE ELEVATION/PLAN VIEW
RP
HR
PCS
PCS
DIM
EN
SIO
N A
R
STRUCTURAL PYRAMID ELEVATION/PLAN VIEW
HR
P
PCS
PCS
DIM
EN
SIO
N A
R
Single-Glazed Double-Glazed Outside Curb Dimension A Height
160-12 161-12 12' x 12' 2'-6"
160-16 161-16 16' x 16' 3'-4"
160-20 161-20 20' x 20' 4'-2"
GLAZING: Acrylic; Monolithic & Structured Sheet Polycarbonate GLAZING: Glass
Laminated Insulated Outside Curb Dimension A Height
162-12 163-12 12' x 12' 2'-6"
162-16 163-16 16' x 16' 3'-4"
162-20 163-20 20' x 20' 4'-2"
Hipped Ends
Laminated Insulated Outside Curb Dimension A Height
184-12 185-12 12' 2'-6"
184-16 185-16 16' 3'-4"
184-20 185-20 20' 4'-2"
Gabled Ends
Laminated Insulated Outside Curb Dimension A Height
186-12 187-12 12' 2'-6"
186-16 187-16 16' 3'-4"
186-20 187-20 20' 4'-2"
Laminated Insulated Outside Curb Dimension A Height
162-12 163-12 12' x 12' 2'-6"
162-16 163-16 16' x 16' 3'-4"
162-20 163-20 20' x 20' 4'-2"
9
Specifications: Structural Polygon Skylights shall be as manufactured by Plasteco, Inc., Houston, Texas (713.673.7710; Fax 713.673.7236). Manufacturer shall furnish a complete K-D structural framing consisting of curb rail, of 6063-T5 mill finish (anodized or painted finish also available) extruded aluminum or field assembly by others to support a minimum load of 20 psf. Units shall be furnished mounted in a 6063-T5 extruded aluminum frame (specify finish). Glazing to be as specified by architect.
Curbs shall be furnished by others to Plasteco’s dimension. Structural integrity of curb and supporting structure is the responsibility of architect/engineer. Curbs to be flashed by others. Skylights shall have an integral system of condensation gutters with drainage to exterior. Weepholes shall not be exposed to view and shall have a buffer type air cover.
STRUCTURAL POLYGON SKYLIGHTS
STRUCTURAL POLYGON ELEVATION/PLAN VIEW
P
R
DIMENSION A
PCS
Single-Glazed Double-Glazed Outside Curb Dimension A Height No. of Segments
170-10 171-10 10'-0" 2'-1" 8
170-12 171-12 12'-0" 2'-6" 8
170-16 171-16 16'-0" 3'-4" 12
170-20 171-20 20'-0" 4'-2" 16
GLAZING: Acrylic; Monolithic & Structured Sheet Polycarbonate
GLAZING: Glass
Single-Glazed Double-Glazed Outside Curb Dimension A Height No. of Segments
172-10 173-10 10'-0" 2'-1" 8
172-12 173-12 12'-0" 2'-6" 8
172-16 173-16 16'-0" 3'-4" 12
172-20 173-20 20'-0" 4'-2" 16
GLASS STRUCTURAL RIDGE, PYRAMID & POLYGON DETAILS
SILL PURLIN
GLASS PER SPECS
.040" ALUMINUM
TOP OF CURB
3/4"
1/4"
CLAMP BAR
CLOSURE ADAPTER
6"2"
END CAP COVER
.040" ALUM. CURB FLASHING
RAFTER
3" x 5" x 1/4" ALUM. ANGLE (2) PER RAFTER ATTACHED TO RAFTER
SECTION SILLPCS
ROOF MEMBRANE OR FLASHING (NOT BY PLASTECO) - MUST BEIN PLACE PRIOR TO INSTALLATION OF CLOSURE CLIP AND PAN FLASHING
OUTSIDE CURB DIMENSION
PLASTIC STRUCTURAL RIDGE, PYRAMID & POLYGON DETAILS
HIP RAFTER ADAPTER
RAFTER
CLAMP BAR
SECTION HIP RAFTERHR
SECTION PURLINP
CLAMP BARGLASS PER SPECS
RAFTER
SECTION RAFTERR
RIDGE CAP
PURLIN BASE
GLASS PER SPECS
FULL PENETRATIONWELD
SECTION HIP RAFTER (HR) SECTION RAFTER (R) SECTION PURLIN (P)
DOME GLAZING
HIP RAFTER
RAFTER
DOME GLAZING
DOME GLAZING
CLAMP BAR
RAFTEROR JACK RAFTER
PURLIN TOP
PURLIN BOTTOM
CLAMP BAR
GASKETGASKET
CLAMP BAR
INNER GASKET
INNER GASKET
RAFTER
HIP RAFTER ADAPTER
6"
TOP OF CURB
1.1/8" DIA. OPEN CELLBACKER ROD
ROOF MEMBRANE OR FLASHING(NOT BY PLASTECO) - MUST BE
1" x 2" x 1/8" SILLPURLIN CLIP - ATTACHTO RAFTER W/ (2) #14
x 1" HWHSDS
.040" ALUM. SILL CLOSUREATTACH TO ADAPTER W/ #8 x
3/4" HWHSDS @ 24" O.C.MIN. 3" OVERLAP @ SPLICES
3"
IN PLACE PRIOR TO INSTALLATIONOF CLOSURE CLIP AND PAN FLASHING
CLAMP BAR
DOME GLAZING
.040" ALUM. CURB FLASHING - MIN.3" OVERLAP AT SPLICES
2"X6"(2) WOOD BLOCKING(NOT BY PLASTECO)
34"
5 12" MIN.
OUTSIDE CURB DIMENSION
SECTION SILL PCS
PURLIN BOTTOM
3" x 5" x 1/4" ALUM. ANGLE (AC801)(2) PER RAFTER ATTACHED TO RAFTERHHMB, HEX NUT & LOCK WASHERATTACH TO WOOD CURB
PURLIN TOP
10
• Factory assembled under a controlled environment • Pre-glazed at factory under dust-free conditions • Completely welded modular units • Baffle weep and internal gutter system — no leaks • Installation is simple — screw in place — no miscellaneous hardware • Installation is faster — there is no roof assembly of components • Installation is economical — no glazier required
Specifications: Manufacturer: Skylights shall be Custom Skylight System 71-TG as manufactured by Plasteco, Inc., Houston, Texas (713.673.7710; Fax 713.673.7236). Alternate manufacturers must have architect’s approval in writing ten (10) days prior to bid date.
Design requirements: All skylights shall be of type and size shown on architect’s plans in accordance with standard Plasteco details. Skylight system shall consist of factory-assembled, pre-glazed units and all split mullion covers, gaskets and fasteners required to make field joints between units. Skylights shall have an integral, interior system of condensation gutters capable of draining across slope and down slope. Outer skylight members at split mullions and walls shall have an integral elevated coaming as a waterstop and for attachment (by others) of split mullion covers and flashings.
Material: All skylight frames, inner and outer mullions, and mullion covers shall be of extruded or sheet aluminum with standard mill finish. Factory-assembled frame members, except movable parts, shall be heliarc-welded. Exposed fasteners throughout shall be stainless steel.
Glazing: Domes (or pyramids) shall be formed of (color) acrylic to support a 40 psf live load. (Where applicable, add: Inner domes (or pyramids) shall be formed of (color) acrylic. All glazing shall bear on continuous neoprene gaskets and have continuous butyl sealant.
Work by others: Curbs, supports and blocking; installation of skylight units and metal flashings.
Add alternate: Fall protection as required by OSHA Regulation 1926.501 “Duty to Have Fall Protection” shall be provided by Model A FallGuard® Skylight Screens. FallGuard® Skylight Screens shall be shipped separately.
TANDEM & GRID SKYLIGHTS
MODEL 71-TG TANDEM & GRID PRE-GLAZED SKYLIGHT SYSTEM
PC
SMIM
IM
STANDARD SIZE TANDEM & GRID UNITS
SM
PCPC
OUTSIDE CURB DIMENSION
OUTSIDE CURB DIMENSION
ENDUNIT
INTERMEDIATEUNIT
ENDUNIT
MIN. SLOPE1/4" PER FT.
(SM must follow slope)
PC
IMSM
45∞ Square Pyramid
MIN. SLOPE1/4" PER FT.
(SM must follow slope)
4 OR 5UNIT
TYPICAL
OUTSIDE CURB DIMENSIONOUTSIDE CURB DIMENSION
FALLGUARD SKYLIGHT SCREEN(PATEN NO. 5,237,788)
(SEE SPEC- ADD ALTERNATE)
WEEP HOLESAT 9" O.C.
INNER GASKET
3/16" X 1/2" BUTYL TAPE
PERIMETER CURB SECTION
FALLGUARD RAIL(OPTIONAL)
OUTSIDE CURB DIMENSION
SELF-ADJUSTINGCOUNTER FLASHING 4" MIN. TO TOP
OF CANT STRIP6" MIN TO ROOF LINE
#10 X 2 HHSMS@ 15" O.C
(NOT BY PLASTECO)
ROOF MEMBRANE ORFLASHING (NOT BY
PLASTECO)
OUTER & INNER GLAZE(DOMES OR PYRAMIDS)
716"
1 12"
3 1/2" MIN.
SPLIT MULLION COVER
OUTER FRAMEEXTRUDED ALUM.
INNER FRAMESPLIT MULLION
OUTER GASKETGLAZING
(SINGLE OR DOUBLE)
INNER GASKET
SECTION SM
SECTION IM
MULLION COVER
CENTER SUPPORT
2"X4" WOOD CURB
MULLION
(NOT BY PLASTECO)
1 516"
GLAZING(SINGLE OR DOUBLE)
FALLGUARD SKYLIGHT SCREEN(PATEN NO. 5,237,788)
(SEE SPEC- ADD ALTERNATE)
WEEP HOLESAT 9" O.C.
INNER GASKET
3/16" X 1/2" BUTYL TAPE
PERIMETER CURB SECTION
FALLGUARD RAIL(OPTIONAL)
OUTSIDE CURB DIMENSION
SELF-ADJUSTINGCOUNTER FLASHING 4" MIN. TO TOP
OF CANT STRIP6" MIN TO ROOF LINE
#10 X 2 HHSMS@ 15" O.C
(NOT BY PLASTECO)
ROOF MEMBRANE ORFLASHING (NOT BY
PLASTECO)
OUTER & INNER GLAZE(DOMES OR PYRAMIDS)
716"
1 12"
3 1/2" MIN.
SPLIT MULLION COVER
OUTER FRAMEEXTRUDED ALUM.
INNER FRAMESPLIT MULLION
OUTER GASKETGLAZING
(SINGLE OR DOUBLE)
INNER GASKET
SECTION SM
SECTION IM
MULLION COVER
CENTER SUPPORT
2"X4" WOOD CURB
MULLION
(NOT BY PLASTECO)
1 516"
GLAZING(SINGLE OR DOUBLE)
FALLGUARD SKYLIGHT SCREEN(PATEN NO. 5,237,788)
(SEE SPEC- ADD ALTERNATE)
WEEP HOLESAT 9" O.C.
INNER GASKET
3/16" X 1/2" BUTYL TAPE
PERIMETER CURB SECTION
FALLGUARD RAIL(OPTIONAL)
OUTSIDE CURB DIMENSION
SELF-ADJUSTINGCOUNTER FLASHING 4" MIN. TO TOP
OF CANT STRIP6" MIN TO ROOF LINE
#10 X 2 HHSMS@ 15" O.C
(NOT BY PLASTECO)
ROOF MEMBRANE ORFLASHING (NOT BY
PLASTECO)
OUTER & INNER GLAZE(DOMES OR PYRAMIDS)
716"
1 12"
3 1/2" MIN.
SPLIT MULLION COVER
OUTER FRAMEEXTRUDED ALUM.
INNER FRAMESPLIT MULLION
OUTER GASKETGLAZING
(SINGLE OR DOUBLE)
INNER GASKET
SECTION SM
SECTION IM
MULLION COVER
CENTER SUPPORT
2"X4" WOOD CURB
MULLION
(NOT BY PLASTECO)
1 516"
GLAZING(SINGLE OR DOUBLE)
11
AUTOMATIC MELT-OUT (DROP-OUT) HEAT AND SMOKE VENTS
Specifications: Automatic Melt-out Heat and Smoke Vents shall be single glazed or double glazed as manufactured by Plasteco, Inc. Houston, Texas.
Units shall have a 12-inch high double wall insulated aluminum curb. Inner and outer frames shall be mill finish 6063-T5 extruded aluminum. Glazing shall be white translucent acrylic designed to withstand a 40 psf snow load. (Double glazed unit add the words “inner pyramid shall be of a clear acrylic”.)
MODEL 417D-5098
MODELS 417 AND 418
Plasteco Model 417, 417D, 418 and 418D automatic melt-out (drop-out) heat and smoke vents feature plastic glazing that will melt-out (drop-out) in less than 5 minutes at a temperature not exceeding 500°F.
Models 417 (single glazed) and 418 (double glazed) have a 12" high aluminum curb. The curb has 1-1/2" thick insulation and a 2" x 4" wood nailer. Models 417D (single glazed) and 418D (double glazed) have a 12" high double wall, 1" thick insulated curb normally used on membrane roofs.
MODEL 417D-MB AND 418D-MB
Plasteco Model 417D-MB automatic melt-out (drop-out) heat and smoke vents feature plastic glazing that will melt-out (drop-out) in less than 5 minutes at a temperature not exceeding 500°F. Models 417-MB and 418-MB double wall are for mounting on standing seam metal roofs.
Single-Glazed Double-Glazed Inside Curb Dimension A
417D-MB-5050 418D-MB-5050 48" x 48"
417D-MB-5098 418D-MB-5098 48" x 96"
MODELS 407 AND 408
Models 407 and 408 curb mounted heat and smoke vents are identical in design to our 417 and 418 models, except the units that do not have a 12" high curb.
Single-Glazed Double-Glazed Outside Curb Dimension A
407-5050 408-5050 51” x 51”
407-5098 408-5098 51” x 99”
Wood Nailer Double Wall Inside Curb
Single-Glazed Double-Glazed Single-Glazed Double-Glazed Dimension “A”
417-5050 418-5050 417D-5050 418D-5050 48" x 48"
417-5098 418-5098 417D-5098 418D-5098 48" x 96"
MODEL 417-MB-5098
Fall protection as required by OSHA Regulation §1926.50 “Duty to have Fall Protection” shall be provided by FALLGUARD® Skylight Screens. FALLGUARD® Skylight Screen shall be shipped separately and installed prior to the installation of the melt-out heat and smoke vent.
Add alternate: Hail Stone Screens shall be 1" x 1" x .063" galvanized welded wire mesh overlaid onto the FALLGUARD® Skylight Screens. Screens shall have been tested to resist without permanent deformation, the impact energy of a 2" diameter hail stone (22 ft lbs).
INSIDE CURB DIMENSION "A"
DOUBLE WALLALUM. CURB
INNER FRAME
OUTER FRAME
FALLGUARD SKYLIGHT SCREEN(PATEN NO. 5,237,788)
(SEE SPEC- ADD ALTERNATE)
3" FLANGE
12" C
URB
HEIG
HT
CAP
OUTER PYRAMID(MODEL 417)
INNER PYRAMID(MODEL 418)
CENTER SUPPORT
MODEL 417 & 418
OUTSIDE CURB DIMENSION "A"
DOUBLE WALLALUM. CURB
INNER FRAME
OUTER FRAME
FALLGUARD SKYLIGHT SCREEN(PATEN NO. 5,237,788)
(SEE SPEC- ADD ALTERNATE) CAP
OUTER PYRAMID(MODEL 417)
INNER PYRAMID(MODEL 418)
CENTER SUPPORT
MODEL 407 & 408
CURB BY OTHERS
1 12" MIN.
Brand new skylights offer aesthetic appeal and allow the beauty of natural light to fill your building. However, choose the wrong skylights, and it’s only a matter of time before that fades.
Acrylic skylights from Plasteco are proven to withstand the test of time. While translucent sandwich panel skylights may originally appear white and clear, time and conditions such as UV rays, pollution, chemical exposure and weather will cause yellowing and increased cloudiness long before the skylight has reached the end of its life cycle.
Ensure your skylights will look like new for years to come when you choose acrylic skylights from Plasteco.
PLASTECO’S ACRYLIC SKYLIGHTS STAND THE TEST OF TIME
Plasteco provided and installed the skylights in Houston’s Astrodome, a structure more than 40 years old that still has the same acrylic glazing.
This is an actual piece of panel skylight that was replaced. The left side was protected from the elements by aluminum flashing, while the right side was exposed. Notice the drastic difference.
This translucent sandwich panel skylight already shows extreme signs of wear, with yellowing and cloudiness preventing the admittance of light into the building.
With acrylic skylights from Plasteco, the same building is flooded with natural light. Our skylights last longer than those made of fiberglass without succumbing to yellowing and cloudiness.
BEFORE
AFTER
12
13
OSHA REQUIRES THAT ALL SKYLIGHTS HAVE ADDITIONAL FALL PROTECTION
OSHA considers falls one of constructions “fatal four.” According to OSHA’s 2012 report, 34.6 percent of deaths in the construction industry are related to falls. In order to
prevent one of the deadliest workplace hazards, OSHA regulation 29 CFR 1910.30 (a)(4) requires all skylights have some sort of fall protection.
While some skylight manufacturers claim that their skylights are OSHA-compliant and meet weight requirements, this isn’t true. Although they may support the weight of a human when brand new, ALL plastic skylights degrade over time and should be protected by a skylight screen or fixed standard railing in order to meet OSHA regulation 29 CFR 1910.30 (a) (4), but even more importantly, to prevent fatal accidents caused by falls through skylights.
ALL PLASTIC SKYLIGHTS DEGRADE OVER TIMEManufacturers’ claims that skylights can withstand a 200 to 300 pound load only apply to brand new skylights. The composition of all plastic skylights will degrade over time from exposure to normal weather conditions and pollution, causing the weight-bearing capabilities diminish long before your skylight has reached the end of its life cycle. This degradation can be seen in the yellowing and increased cloudiness of your skylight over time.
According to California Fatality Assessment and Control Evaluation (CA/FACE) Report #09CA003, the label on a skylight involved in a fatal fall stated it was tested in accordance with OSHA fall protection standards. Because of this label, no other fall protection was implemented. DO NOT BE MISLED. While a skylight may meet OSHA standards when new, its weight-bearing capacity will diminish over time and must be protected.
Don’t put workers at risk by taking a chance on unprotected skylights that may fail! Install FallGuard® Safety Screens from Plasteco today.
1992SINCE
The same skylight, years later, breaks in real-world conditions. Source: FACE Report #09CA003
The label on the skylight stated it was tested in accordance with OSHA Fall Protection standards.
THE ONLY WAY TO PREVENT TRAGIC ACCIDENTS IS WITH FALL PROTECTIONEnsure worker safety and OSHA compliance with FallGuard® Skylight Screens from Plasteco.
Plasteco was the first to offer FallGuard® screens for all skylight models, including all models from outside manufacturers. For more than 20 years, Plasteco’s FallGuard® Skylight Safety Screens have been protecting workers and saving lives.
14
16
MODEL F FALLGUARD® SKYLIGHT SCREENS
The Model F FallGuard® Skylight Screens PREVENTS falls through corrugated fiberglass (CF) skylights. They are simple to install and will prove to be cost effective in view of the exposure in time and dollars expended as a result of a fall through a CF skylight. Being at the same level and having the same profile as the corrugated metal roof panels, they are at times difficult to detect by persons on the roof.
Patent No. 5,419,090
MODEL TSSR FALLGUARD® SKYLIGHT SCREENS
Model TSSR FallGuard® Skylight Screens PREVENT falls through trapezoidal standing seam skylights. These skylights are similar to the regular corrugated fiberglass skylights in that they are at the same level as the roof and have the same profile. They can be easily overlooked when a person is working or walking on the roof. The FallGuard® Skylight Screens are easy to install and allow for a proactive rather than reactive solution to a safety hazard. They, like other FallGuard® Skylight Screen models, will prove to be more than cost effective considering the alternative of a fall through a skylight.
Patent Pending
INSTALLATION INSTRUCTIONS
Do not place body weight on skylight during installation. Use extreme caution when installing the FallGuard® Skylight Screens. Wear gloves when handling skylight screens.
1. The FallGuard® Skylight Screen channel is to be mounted on the highest corrugation nearest to the center of the skylight.
2. On the high end, the fiberglass skylight should be under the corrugated metal. Clean and install the 3" x 3" adhesive sealant pads on the corrugated metal approximately 1" from the edge. Be sure to remove the release liner from the adhesive sealant pads.
3. Position the FallGuard® channel so that the three mounting holes in the channel are positioned over the 3" x 3" adhesive pads.
4. Fasten the high end of the FallGuard® channel to the corrugated metal using the self-drilling screws.
5. Proceed to lower end of the FallGuard® channel. Clean area under the three holes in the channel and install the 3" x 3" adhesive sealant pads. Fasten the lower end of the FallGuard® channel to the corrugated metal.
6. Center the FallGuard® Skylight Screen over skylight and insert the FallGuard® Skylight Screen under the tabs. Bend tabs over the FallGuard® Skylight Screen.
Specifications: Skylight Screens shall be Model F FallGuard® Skylight Screens manufactured by Plasteco, Inc., Houston, Texas (713.673.7710; Fax 713.673.7236). Each skylight screen shall consist of a 3" x 4" welded wire mesh having a minimum transverse diameter of .195". A plastic bumper extrusion shall be installed around the perimeter of the skylight screen. The skylight screen is to be field installed on a 20 gauge galvanized steel channel. The steel channel shall have tabs to receive the skylight screens and pre-punched holes for the mounting screens. Two 3" x 3" sealant adhesive pads and six hex washer head self-drilling screws shall be furnished with each channel.