16
www.hitechsolution.co.in GENERATION FOUR ENGITECH LTD. SILICON GREEN SYNTHETIC THERMIC FLUID ISO 9001:2008 CERTIFICATION

CERTIFICATION GENERATION FOUR ENGITECH LTD.hitechsolution.co.in/wp-content/uploads/2018/11/Hitech-Therm-60.pdf · (champalal group) paramount aromachem pvt ltd viraj fab pvt ltd bhismak

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

www.hitechsolution.co.in

GENERATION FOUR ENGITECH LTD.

SILICON GREEN SYNTHETIC THERMIC FLUID

ISO9001:2008

C E R T I F I C A T I O N

Profile

Our Collaboration

SOURCE EXPLORER Ltd.

St Box No : 91642,Nathan Road.

TSIM SHATSUI, Hongkong.

IMP

OR

TING

FORMULATIN

GMARKETING

DEL

IVER

ING

ANALYZINGNEEDS

GENERATION FOUR ENGITECH LTD.

GENERATION FOUR ENGITECH LTD.

Wait a sec!!!!!

GAUGE GLASS

BYPASS LINEFLUIDSED BED HUSK /

COAL FIRED THERMIC FLUID HEATERHEATING SYSTEM

FOR PLATTEN PROCESSES

EXPANSION CUM DEAERATOR TANK

LIQUID LEVEL SWITCH

COLD FLUID

THERMIC FLUID RETURN LINE

THERMIC FLUID SUPPLY LINE

VALVE

HOT FLUID

CIRCULATING PUMPTHERMIC FLUID BUCKET FILTER

Using Heat Transfer System ?

Searching For Efficient Thermic Fluid???Which can provide :• High efficiency incorporated with • Effective cost• Safety to the devices and• Clean Environment

Then..... go for HiTech Therm - 60

GENERATION FOUR ENGITECH LTD.

Our Product

“Speed” “Innovation” “Excellence"The G4’s DNA ?

High Oxidation Stability

Reduces Problemof Low & High

Boilers

Almost NegligibleCarbon Contents

Lower Top UpRequirement

Has Long Life

High Thermal Stability

Hi- Tech Hi- Tech Therm 60Therm 60Hi- Tech

Therm 60Hi- Tech Hi- Tech

Therm 60Therm 60Hi- Tech

Therm 60

GENERATION FOUR ENGITECH LTD.

Physical Properties Composition

Mixture of synthetic fluid (100%)

Appearance

Silicon Green liquid

320°C608°F

Max. bulk Temperature

-40°C-40°F

Pour Point

<90 ppm

Moisture content

Total Acid Numbers

0.01 mg KOH/g

Coefficient of thermal expansion

0.00096/°C

Boiling point@1013 mbar

361°C682°F

Flash point

(ASTM D-92)205°C401°F

20cSt

oKinematic Viscosity @ 40 C

GENERATION FOUR ENGITECH LTD.

Tabulation of Properties of Hitech Therm 60 with respect to Temperature

Figures mentioned above are as per laboratory observation of a particular batch(Test No. KSP1325 13-12-12). These

are for reference only and may vary from batch to batch, hence do not attract any techno-legal reference whatsoever.

-30

-20

-10

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

190

200

210

220

230

240

250

260

270

280

290

300

310

320

1.791

1.802

1.811

1.813

1.843

1.867

1.894

1.935

2.018

2.044

2.077

2.101

2.143

2.179

2.213

2.228

2.291

2.311

2.344

2.379

2.421

2.480

2.493

2.535

2.579

2.599

2.623

2.651

2.709

2.736

2.757

2.814

2.853

2.891

2.915

2.951

0.907

0.901

0.896

0.889

0.880

0.876

0.865

0.860

0.857

0.845

0.840

0.838

0.830

0.823

0.817

0.810

0.748

0.793

0.790

0.782

0.775

0.768

0.762

0.755

0.749

0.739

0.731

0.724

0.717

0.710

0.701

0.694

0.689

0.678

0.670

0.662

1180.5

850

380

159

84

48

30

20

14.3

10.34

7.58

6.98

4.88

3.82

3.12

2.78

2.52

2.00

1.75

1.53

1.38

1.20

1.06

0.90

0.88

0.85

0.80

0.72

0.69

0.65

0.59

0.54

0.51

0.50

0.46

0.42

0.1402

0.1389

0.1377

0.1364

0.1352

0.1339

0.1326

0.1314

0.1301

0.1289

0.1276

0.1263

0.1251

0.1238

0.1225

0.1213

0.1200

0.1188

0.1175

0.1162

0.1150

0.1137

0.1124

0.1119

0.1099

0.1087

0.1074

0.1061

0.1049

0.1036

0.1023

0.1011

0.0998

0.0985

0.0973

0.0960

-

-

-

-

-

-

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.15

.25

0.46

0.83

1.26

2.01

3.18

4.85

7.30

10.10

15.09

20.10

30.30

40.7

59.3

80.0

108.0

135.0

186.0

249

Temperature

°C

Specific Heat

kj/kg°K

Liquid Density

g/mlLiquid Viscosity

cSt

Liquid Thermal

Conductivity W/m.°K

Vapour Pressure

mm-Hg

GENERATION FOUR ENGITECH LTD.

Journey To Excellence - HiTech Therm - 60

We Impart Performance By Providing Assurances For

Product’s wide range of operation.

-20°c to 320°C.

Product’s Long Life.

Product’s Non Fouling.

Product’s Superb Low temperature Pumpability.

Product’s Compatibility with

almost all minerals & synthetic fluids.

Fluid analysis facility.

Thermal stability

High Thermal stability

High Resistance to degradation

Less formation of volatile products

Hence reduces low boiler problems & reduces top ups

Has low viscosity

Higher Flow Rate

Consumes less power & fuel

Enhancing the life & saves fuel

Viscosity

GENERATION FOUR ENGITECH LTD.

WORKING OF SPECIAL DISPERSION AGENT

When heated after a certain period of time:

carbon particles are formed

But the silicone additives make a

layer on these carbon particles and prevent

their sticking. So carbon keeps on flowing without

getting stagnancy.

Silicone additives

SILICONE GREEN SYNTHETIC THERMIC

FLUID

GENERATION FOUR ENGITECH LTD.

Compatibility Process With Other Thermic Fluids

FAQ :

Q What happens when Hi-Tech Therm 60 is mixed with other thermic fluid?

As mineral oils are natural hydrocarbons and Hi-Tech Therm 60 is an enriched hydrocarbon, being the same family they are compatible to each other. Extra additives incorporated in Hi-Tech Them 60 improve performance of any other fluid, new or existing, if added to, as seen below : Decreases the viscosity of existing oil increasing flow rate. Dispersion additive does magic to existing fluid as sticker carbon

particles are removed from pipe line surface and breaking the same to micro form to a certain level.

By making the flash point stable, life of existing fluid is increased by this addition.

Even a percentage change of the existing fluid will give miraculous results. Any accident or mishap will result in overflow of oil and enhancing top-up. So why to wait for an accidents, it is better to top-up with certain percentage of oil as and when needed.

Other Thermic Fluid

STEP - I STEP - II STEP - III

HI-TECHTherm 60

Compatibility modein process

Compatibility mode complete

Silicone green synthetic fluid ‘Hi –Tech Therm 60’ is fully compatible with all type of mineral based thermic fluid like: Hytherm 500-600, Shell Thermia B, Servotherm, Therminol-55 and so on.

GENERATION FOUR ENGITECH LTD.

THERMIC FLUID SYSTEM CLEANING CHEMICAL

Cleaning of Thermic Fluid System

Our ProductClean the

System withMax Efficiency

Efficient Varnish

EmulsificationTechnology

Compatible with all

Thermic Fluids

Economic CostCleaningSolution

Uses CarbonDetergent

Technology

Uses Carbon dispersion Technology

Hi-Tech Hi-Tech Hi-Tech Clean 205Clean 205Clean 205

Hi-TechHi-TechHi-TechClean 206Clean 206Clean 206

Hi-Tech Hi-Tech Hi-Tech Clean 205Clean 205Clean 205

Hi-Tech Hi-Tech Hi-Tech Clean 206Clean 206Clean 206

Cleaning Results

BEFORE AFTER

1. If your oil has carbon content more than 2%.

2. If your radiators are not giving proper heat due to deposition.

3. If your system is above 10-15 years old.

4. If there is heavy carbon formation due to accident in the system.

5. If your running fluid has crossed the standard physical parameters.

When To Clean The System

The nature of varnish is sticky, therefore the contaminants gets stuck in varnish deposits. O u r c l e a n i n g f o r m u l a dissolves the varnish in water & bring these stuck particles into circulation, which gets stuck in varnish over years. These contaminated particles once in circulation can be taken out through the drains.

Understanding The Varnish

GENERATION FOUR ENGITECH LTD.

Testing Thermic Fluid India's Only Specialised Thermic Fluid Testing Lab Facility (Its true - Any lab can test your thermic fluid but you will get benefit only if test's are correct by conducted)

Above tests are essential ones and should be conducted every 4 months. We also undertake other tests relating to thermic fluids. For details contact :

Shri Dhansukh Jain - 092140 48652email : [email protected]

1. Send your Sample in clean, Contamination & moisture free bottle.

2. Send at least 750 ml to 1000ml of thermic fluid

3. It is better to draw sample through needle valve' while pump is running.

4. Throw 200 ml of oil and then collect the oil for sample testing.

5. For proper recommendation fill all columns in testing form.

6. Send Sample to – Generation Four Engitech Ltd. Hitech Solution Mandeep Tower, Residency

R o a d , O p p . S a n k a l p Restaurant, Jodhpur (Raj)

Tel. : 0291-2772655 Mobile : 0 92140 486527. Guideline for Sending sample to

courier. A. Send Sample in Chemical

Sample Bottle Available in Indian Market.

B. Ensure that bottle/can is leakproof.

C. Fill the bottle 100% with no air.

D. Pack the sample in Square box with paper & plastics surrounding.

E. If your Packing is Poor, Courier will not accept the sample.

F. Write Proper Address in D e t a i l s w i t h P h o n e Numbers.

Guide Line O@40 C

Kinematic Viscosity

Flash point

ASTM D-92

Carbon Residue

Result are in %

Suspended Particle & Contamination

Increase in carbon will increase your fuel cost and decrease your machine performance. It is an economical test.

It reflects your fire risk, due to Thermic Fluid which is important for safety.

It is very Important test to check your fluids proper flow rate. i.e. how fas t i s hea t transfer.

We check your oil for suspended particle and contamination, whether parameter exceeds.

GENERATION FOUR ENGITECH LTD.

“Award presented by : Mrs. Shikha Sharma – MD and CEO, Axis Bank”“Award presented by : Mrs. Shikha Sharma – MD and CEO, Axis Bank”“Award accepted by: Mr. Dhansukh Chopra (Director) “Award accepted by: Mr. Dhansukh Chopra (Director)

and Mr. R. P. Vyas (Director) GFEL”and Mr. R. P. Vyas (Director) GFEL”

“Award presented by : Mrs. Shikha Sharma – MD and CEO, Axis Bank”“Award accepted by: Mr. Dhansukh Chopra (Director)

and Mr. R. P. Vyas (Director) GFEL”

AXIS BANK

BUSINESSGaurav

SME AWARDS 2012

Under Sector Under Sector “Chemical and Petrochemicals” “Chemical and Petrochemicals”

as Best as Best Micro Enterprise in IndiaMicro Enterprise in India

Under Sector “Chemical and Petrochemicals”

as Best Micro Enterprise in India

Third Party Recognition

GENERATION FOUR ENGITECH LTD.

Our Golden Clients

ADANIwilmar

ADANI WILMAR AGARWAL FOOD UDAIPUR ASHOKA CHEM FOOD ASHWIN VANASAPTI VAPI BIKAJI

BUNGE DABUR GOVERDHAN INDUSTRIES

JAGANNATH CHEM, NAWA JAYANTI AGRO, ALWAR JK TYRES JYOTHY LABORATORIES LTD.KANDLA ENERGY

AND CHEMICALS LTD.

KR FOODS LTD. LALIT HANS PROTEIN MANAKSIA LTD MARICO

MARUTI TEXTILES MAYUR UNIQUOTERS LTD. METRO PLYWOOD PVT. LTD. MOTHERLAND GARMENTS

MOTIF DECOR PANKAJ SALT INDUSTRIES, NAWA

PARAS VANASPATI

PVT. LTD. RAIPUR PAWAN AGRO INDUSTRIES PIDILITE

PURTI GROUP RACHNA PLASTICIZERS RISHABH RESINS RUCHI SOYA LTD. SK OIL INDUSTRIES

SNR RECLAMATIONS PVT. LTD. SAHIB SYNTHETICS SHREE NAMAK SOMI CONVEYOR BELT

TEX CORP DELHI TIPCO VE COMMERCIAL VEHICLES LTD. VIJAY SOLVEX LTD

VOLTAMP TRANSFORMERS LIMITED YETI POLYCHEM, NEPAL MARUDHAR PAINTS HOMTEK AGRO INDIA AGRO TEC FOOD LTD.

SAHIB SYNTHETICS

PLASTENE INDIA LIMITED

(CHAMPALAL GROUP) PARAMOUNT AROMACHEM PVT LTD

VIRAJ FAB PVT LTD

BHISMAK PLY PVT LTD

MANGAL GEETA FASHIONS

PVT LTD

MURTUZA FOODS PVT LTD

PlasteneIndiaLimited

p r i v a t e l i m i t e d

©

Mangal GeetaFASHION PVT. LTD.

GENERATION FOUR ENGITECH LTD.

Actual Photographs of Generation Four Engitech Ltd. Manufacturing Plant

StorageStorageStorage

Plant’s Wide ViewPlant’s Wide ViewPlant’s Wide View

Additive Blending VesselsAdditive Blending VesselsAdditive Blending Vessels

2000 Ltr.2000 Ltr.2000 Ltr.

25000 Ltr. 2 Blending Vessels25000 Ltr. 2 Blending Vessels25000 Ltr. 2 Blending Vesselswith Hot & Cold Facilitywith Hot & Cold Facilitywith Hot & Cold Facility

3000 Ltr.3000 Ltr.3000 Ltr. 3000 Ltr.3000 Ltr.3000 Ltr.

GENERATION FOUR ENGITECH LTD.

Technical Support (Multi Tiered Technical Support)

Our technical support services are divided into III tier in order to better serve our customer base.

TIER - I 1. This is initial support

level responsible for basic customer issues.

2. It starts with determining the customer’s issue by analyzing the sample.

3. Once identification of the underlying problem is done “ The specialist begins sorting through the possible solutions available

TIER II 1. More in depth technical support level2. Administrative level support.3. Include onsite inspection of system design & networking.4. Compatibility related issues in case of Top-ups on other fluids

TIER III1. Highest level of support.2. Back end support for handling the most difficult or advanced

problem.

Experienced technical service specialist can answer your questions regarding heat transfer fluid selection, system start-ups, system design, and operational issues.call us on:__________or contact : [email protected]

Technical Service

Contact Details :

Admn. Office :Hitech SolutionMumbai Bazar, 387-Last Bus Stop, Park Side, Vikhroli (W) Mumbai -79

Regd. Office :Generation Four Engitech Ltd. - Hitech SolutionMandeep Tower, Residency Road, Opp. Sankalp Restaurant, Jodhpur (Raj)Tel. : 0291-2772655 Mobile : 0 92140 48652

Collaboration with :SOURCE EXPLORER Ltd.St Box No : 91642,Nathan Road. TSIM SHATSUI, Hongkong.

Local Representative :

Disclaimer : Generation Four Engitech Ltd. makes every effort to ensure that the information and data provided are correct. However we can accept no liability or guarantee that the information and data provided is up-to-date, correct and complete. Nor is Generation Four Engitech Ltd. responsible for the contents of such reference information. Generation Four Engitech Ltd. reserves the right to modify of supplement the information or data provided without prior notice.

[email protected]

Mfg. Plant :Generation Four Engitech Ltd.Plot No. 25-A, Raipur Sahakari Industrial Area, Raipur Bhagwanpur, Roorkee, Uttarakhand. Mobile : 09760366343

www.hitechsolution.co.in

[email protected]