FRIALIT® & XiVE®
ANKYLOS®
FRIOS®
PEPGEN P-15®
FRIALIT® & XiVE®
Catalog
0607
09/S
B
ArtKat_FX_Tit_E_rev007 21.06.2007, 10:56 Uhr3
2
FRIALIT® & XiVE®
Catalog
FRIALIT® & XiVE® –Two implant designs, one prosthesis!
The pictures in this catalog are for illustration. The size ofthe illustrated products may deviate from the originalproduct.
DENTSPLY Friadent reserves the right to make anytechnical changes without prior notice.
Information regarding the materials involved in implants,system components and instruments is given in the form ofa reference number after every article: FRIADENT®
Gingiva Former2.Page 87 of this catalog presents an overview of thematerials and the composition of the materials used.
FRIALIT® – The root-analog implant with unlimitedprosthetic options for ultimate esthetics.
XiVE® – The implant design for accelerated treatment withhighest primary stability in all bone qualities.
Ultimate esthetics and accelerated treatment – theFRIALIT® and XiVE® implant options cover all indications.The identical implant-abutment-connection of FRIALIT®
and XiVE® S implants provides a unique platform for theoptimal realization of all prosthetic concepts using thecomponents of FRIADENT® Prosthetics.
XiVE® TG – The transgingival alternative. Single-stagetransgingival XiVE® TG Screw Implants are available inaddition to the subgingival implant design. The super-structure is produced with XiVE® TG prosthetic linecomponents.FRIALIT®
ImplantsXiVE® SImplants
XiVE® TGImplants
XiVE® TGProstheticsFRIADENT® Prosthetics
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:05 Uhr2
3
FRIA
LIT®
XiV
E®X
iVE®
TG
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
Pres
enta
tion
mat
eria
l
FRIALIT® Implants 4
Pre-surgical planning 6Implant placement 9Instruments for implant placement 12
XiVE® Implants 20
Pre-surgical planning 22Implant placement 24Instruments for implant placement 28
FRIADENT® Prosthetics 38
Uncovery 42
Fabrication of superstructure at implant levelSoft tissue management,Provisional restorations 43Impression making 46Prosthetics/laboratory 49
Fabrication of superstructure at gingival level(MP-Abutment)Transgingival extension, temporary sealing 55Impression making 57Prosthetics/laboratory 58
Instruments for impression making/prosthetics/laboratory 62
XiVE® TG Implants and Prosthetics 66
Implant placement 68Instruments for implant placement 70Impression making 72Prosthetics/laboratory 73Instruments for impression making/prosthetics/laboratory 76
Presentation material 78
Appendix 79
Materials 79
Content
Additional DENTSPLY Friadent Product CatalogsOrder No. 6-252004 for ANKYLOS®
Order No. 6-302017 for FRIOS® and PEPGEN P-15®
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:05 Uhr3
FRIALIT®
FRIALIT® plus Implants –Prevention instead of interventionfor perfect esthetics
Innovative esthetic implant concepts should considertooth-by-tooth replacement as early as possible.FRIALIT®, the first root-analog implant geometry in theworld, offers perfect esthetics of peri-implant soft tissues,excellent prosthetic results and long-term success.Following nature’s design, FRIALIT® implants steppeddesign ensures an optimum transfer of occlusal forces.The anatomical diameters allow support of the alveolarbone, reconstruction of the interproximal space andmaintenance of the papillae. Perforating the buccal plateor injuring converging roots during surgery can beavoided since the apical end of the implant is narrower.The implant-abutment connection provides the utmost instability with long parallel-walled sections to resist lateralforces and a deep internal hex to prevent rotation.
4
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:05 Uhr4
FRIA
LIT®
FRIA
LIT®
Indications
Cases:■ where hard and soft tissue atrophy can be prevented
through immediate or delayed-immediate implantplacement
■ with high esthetic demands, particularly in the anteriorregion
■ requiring a natural “emergence profile” based on thecrestal-anatomical implant diameter
■ where trauma to the labial or buccal wall or adjacentanatomical structures can be prevented by using root-analog stepped implants
■ planned for tooth-by-tooth reconstruction
Macro-design
Root-analog, stepped design provides functional transferof occlusal forces, supports peri-implant bone andoverlying soft tissue. The interproximal space and thepapillae are preserved based on the anatomy.
Micro-design
The synchronized thread design of the FRIALIT® plusstepped screw offers increased self-tapping efficiency incortical bone and optimum primary stability with secureretention in soft spongy bone – ideal in all bone qualities.
Nano-design
Growth-activating FRIADENT® plus surface. Steppedscrew implant with trimodal surface morphologyproviding an ideal environment for functional adaptationof epithelium, connective tissue and bone.
Implant diameters
D 3.4 D 3.8 D 4.5 D 5.5 D 6.5
FRIALIT® � � � � �
5
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:05 Uhr5
6
Pre-surgical planning
45 – 5020 FRIALIT® Select Basic Set CompleteThe Basic Set includes for each implant diameter– one straight FRIADENT® Select Try-in Abutment and the
D 3.4 and D 3.8/A 15 angled Select Try-in Abutment– one FRIADENT® Select Sleeve and the pin– one FRIALIT® Select Try-in Implant– Implant Forceps– one Select Tray
Try-in Abutments
Gingival height, angulation and the correct position of the horizontal screw(GH 2) for FRIADENT® abutments can easily and quickly be determined withthe FRIADENT® Select Try-in Abutments.
45 – 2190 FRIADENT® Basic Set Select Try-in AbutmentThe Basic Set consists of a FRIADENT® Select Try-in AbutmentA 0, straight for each implant diameter and the FRIADENT®
Select Try-in Abutments D 3.4 and D 3.8/A 15, angled.
FRIADENT® Select Try-in Abutment2
45 – 2120 – � D 3.4/A 0 (straight)45 – 2121 – � D 3.8/A 0 (straight)45 – 2122 – � D 4.5/A 0 (straight)45 – 2123 – � D 5.5/A 0 (straight)45 – 2220 – � D 3.4/A 15 (angled 15°)45 – 2221 – � D 3.8/A 15 (angled 15°)
FRIADENT® Select Multipack Try-in Abutment (3 pieces)
45 – 2193 – � D 3.4/A 0 (straight, 3 pieces)45 – 2194 – � D 3.8/A 0 (straight, 3 pieces)45 – 2195 – � D 4.5/A 0 (straight, 3 pieces)45 – 2196 – � D 5.5/A 0 (straight, 3 pieces)45 – 2293 – � D 3.4/A 15 (angled 15°, 3 pieces)45 – 2294 – � D 3.8/A 15 (angled 15°, 3 pieces)
Order No. Article
FRIADENT® Select Try-in Abutments and Sleeves can be used either forFRIALIT® or XiVE® implants. The design of the Select Try-in Abutments has beenadapted to the special implant geometries. Therefore, different Try-in Implants(FRIALIT® or XiVE®) have to be used for FRIALIT® and XiVE®.
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:05 Uhr6
7
FRIA
LIT®
Sleeves
FRIADENT® Select Sleeves allow for an exact transfer of the pre-prostheticplanning to the clinical situation.
45 – 5090 FRIADENT® Select Basic Set SleeveThe Basic Set contains one pin and one FRIADENT® SelectSleeve per implant diameter.
FRIADENT® Select Sleeve2
without pin
45 – 5035 – � D 3.445 – 5045 – � D 3.845 – 5055 – � D 4.545 – 5065 – � D 5.545 – 5075 – � D 6.5
FRIADENT® Multipack Select Sleeve(3 pieces, without pin)
45 – 5095 – � D 3.4 (3 pieces)45 – 5091 – � D 3.8 (3 pieces)45 – 5092 – � D 4.5 (3 pieces)45 – 5093 – � D 5.5 (3 pieces)45 – 5094 – � D 6.5 (3 pieces)
91 – 4502 FRIADENT® Khoury Drill Guide Pin2
Try-in Implants
With FRIALIT® Select Try-in Implants you can verify implant position, implantaxis and the implant position in relation to the bone crest during surgery. Thethickness of the the soft tissue can be measured.
45 – 5080 FRIALIT® Select Basic Set Try-in ImplantThe Basic Set contains one FRIALIT® Select Try-in Implantper implant diameter.
FRIALIT® Select Try-in Implant2
45 – 5030 – � D 3.445 – 5040 – � D 3.845 – 5050 – � D 4.545 – 5060 – � D 5.545 – 5070 – � D 6.5
FRIALIT® Multipack Select Try-in Implant (3 pieces)
45 – 5085 – � D 3.4 (3 pieces)45 – 5081 – � D 3.8 (3 pieces)45 – 5082 – � D 4.5 (3 pieces)45 – 5083 – � D 5.5 (3 pieces)45 – 5084 – � D 6.5 (3 pieces)
Order No. Article
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:05 Uhr7
8
Order No. Article
Pre-surgical planning
48 – 0040 FRIALIT® Select Tray (empty)
Others
49 – 1211 FRIADENT® Radiographic Balls for pre-surgical planning6
(Ø 5 mm), quantity: 12
45 – 5570 FRIALIT® Radiographic Template(Scales 1:1; 1.3:1; 1.7:1)
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:05 Uhr8
9
FRIA
LIT®
Implant placement
FRIADENT® sterile packagingfor implants
All FRIADENT® implants are packed in gamma sterilized,sealed transparent double vials. An adhesive label sealsthe color-coded cap with the non-sterile outer vial. Theblister is also non-sterile.
■ Transparent outer vial –to see the content
■ Color-coded cap displaying the implant length –for clear identification
■ Sterile inner vial with implant retaining stopper –for fast and safe no-touch placement of implants
■ Peel-off labels –for a reliable documentation
FRIADENT® sterile packaging forFRIALIT® Screw Implants
No-touch insertion FRIALIT® implants
The undamaged label clearly indicates that thesterile package has not been opened and thus
product sterility.
1. Remove the cap from theouter vial (non-sterile)
and slide the inner vial(sterile) onto the surgicaltray.
Color-coded cap matchingthe implant diameter
Retaining stopper
Cover screw
Stepped screw withplacement head
Polycarbonateinner vial (sterile)
Outer vial (non-sterile)
The Cover Screw of FRIALIT® SteppedCylinders is already in the implant.
2. Remove the implant viathe silicone stopper withouttouching the inner vial.
3. Insert the FRIALIT® implant dependent on the implanttype. Please follow the instructions for use.
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:05 Uhr9
10
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:05 Uhr10
11
Implant placement
Implants (sterile)
FRIALIT® plus Stepped ScrewContent: Stepped Screw, Placement Head2
and Cover Screw2
36 – 0431 – � D 3.4/L 11 3
36 – 0433 – � D 3.4/L 13 3
36 – 0435 – � D 3.4/L 15 3
36 – 0441 – � D 3.8/L 11 2
36 – 0443 – � D 3.8/L 13 2
36 – 0445 – � D 3.8/L 15 2
36 – 0450 – � D 4.5/L 8 2
36 – 0451 – � D 4.5/L 10 2
36 – 0453 – � D 4.5/L 13 2
36 – 0455 – � D 4.5/L 15 2
36 – 0460 – � D 5.5/L 8 2
36 – 0461 – � D 5.5/L 10 2
36 – 0463 – � D 5.5/L 13 2
36 – 0465 – � D 5.5/L 15 2
36 – 0471 – � D 6.5/L 10 2
36 – 0473 – � D 6.5/L 13 2
36 – 0475 – � D 6.5/L 15 2
Order No. Article
FRIA
LIT®
Before rotating the FRIALIT® Screw Implant into place, the Placement Head isremoved with the 0.9 mm FRIADENT® Hex Driver. To complete the insertion,use the FRIALIT® Stepped Screw Implant Driver for ratchet or handpiece(see page 18).
The Cover Screw for FRIALIT® Stepped Screw Implants is located in thesilicone stopper of the inner vial.
The Cover Screws are seated in with the 0.9 mm FRIADENT® Hex Driver orwith the blade width 2.0 mm FRIADENT® Screwdriver.
FRIADENT® Cover Screw for Implants2
45 – 1130 – � D 3.445 – 1140 – � D 3.845 – 1150 – � D 4.545 – 1160 – � D 5.545 – 1170 – � D 6.5
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:05 Uhr11
12
Instruments for implant placement
FRIALIT®
Stepped Screw D 3.4FRIALIT®
Stepped Cylinder D 3.4
FRIALIT®
Twist DrillD 2.0
FRIALIT®
Round Drill
FRIALIT®
Stepped Screw D 3.8FRIALIT®
Stepped Cylinder D 3.8
FRIALIT®
Stepped Screw D 4.5FRIALIT®
Stepped Cylinder D 4.5
FRIALIT®
Stepped Screw D 5.5FRIALIT®
Stepped Cylinder D 5.5
FRIALIT®
Stepped Screw D 6.5FRIALIT®
Stepped Cylinder D 6.5
FRIALIT®
Stepped DrillD 3.4
A successful implant placement requires precise andcareful implant site preparation. Therefore, please followour recommendations for drilling exactly.
FRIALIT® Twist Drills and Stepped DrillsFRIALIT® Twist Drills and Stepped Drills are used at800 rpm. In very dense cortical bone the diameter5.5 mm and 6.5 mm stepped drills are used at amaximum speed of 400 to 500 rpm. During thepreparation make sure drills are adequately internallyand externally irrigated.
FRIALIT® Cortical DrillDense cortical bone (type I bone)frequently exhibits elastic forces afterimplant site preparation.Additional preparation of the topstep with the FRIALIT® Cortical Drillcan compensate for this effect.
The FRIALIT® Cortical Drill gentlyexpands the implant site asrequired by increasing the diameter
of the first step by 1/10 mm andthus allows for an easy and atraumatic implant insertionavoiding a too high insertion torque.
FRIALIT® BoneCondenserIn cases of poor bone quality, FRIALIT® BoneCondenserscan be used for lateral and apical implant sitecondensation. This improvement of bone quality andquantity enhances primary implant stabilization.
The FRIALIT® drill sequence
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:05 Uhr12
13
FRIA
LIT®
FRIALIT®
Stepped DrillD 3.8
FRIALIT®
Stepped DrillD 5.5
Cortical DrillD 4.5
Cortical DrillD 5.5
Cortical DrillD 6.5
FRIALIT®
Stepped DrillD 6.5
Cortical DrillD 3.8
FRIALIT®
Stepped DrillD 4.5
For type I bone
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:05 Uhr13
14
FRIALIT Sets Surgical Instruments
The instrument sets contain all instrumentsrequired for implant placement.The kits are supplied in the new FRIALIT Surgical Tray.
45 – 8072 FRIALIT Basic Set Surgery
45 – 8090 FRIALIT Expert Set Surgery
Contents: StarterSet ExpertSet
Radiographic Balls for pre-surgicalplanning (5 pcs.) ■ ■
FRIALIT® Select Try-in ImplantStarterSet ■
FRIALIT® Select Try-in ImplantD 3.4 ■
FRIADENT® Select Try-in AbutmentStarterSet ■
FRIADENT® Select Try-in AbutmentD 3.4 ■
FRIADENT® Select Try-in AbutmentD 3.4/A 15 (angled 15°) ■
Fitting Tool for Depth Stops ■ ■
Depth Gauge D 2 ■ ■
Twist Drill D 2 (with 4 Depth Stops) ■ ■
Stepped Drill D 3.4 (with 5 Depth Stops) ■ ■
Round Drill ■ ■
Stepped Drill D 3.8 universal(with 4 Depth Stops) ■ ■
Stepped Drill D 4.5/L 8 ■
Stepped Drill D 4.5/L 10 ■ ■
Stepped Drill D 4.5/L 13 ■ ■
Stepped Drill D 4.5/L 15 ■ ■
Stepped Drill D 5.5/L 8 ■
Stepped Drill D 5.5/L 10 ■ ■
Stepped Drill D 5.5/L 13 ■ ■
Stepped Drill D 5.5/L 15 ■ ■
Stepped Drill D 6.5/L 10 ■
Stepped Drill D 6.5/L 13 ■ ■
Stepped Drill D 6.5/L 15 ■ ■
Cortical Drill D 3.8 ■
Cortical Drill D 4.5 ■
Cortical Drill D 5.5 ■
Cortical Drill D 6.5 ■
Drill Extension ■
Long Internal Irrigation Tube ■
Drill Cleaning Instrument ■ ■
Contents: StarterSet ExpertSet
Handpiece Stepped ScrewImplant Driver D 3.8 – D 6.5 ■
Handpiece Stepped ScrewImplant Driver D 3.4 ■
Ratchet Stepped ScrewImplant Driver
– 12 mm ■ ■
– 16 mm ■ ■
– 20 mm ■ ■
FRIADENT Ratchet ■ ■
FRIADENT Ratchet Insert forImplant Driver ■ ■
Seating Instrumentfor Cylinder Implants standard ■ ■
Seating Instrumentfor Cylinder Implants posterior ■ ■
Handpiece Hex Driver0.9 mm ■ ■
Ratchet Hex Driver0.9 mm ■ ■
Handpiece Slot Screwdriver ■
Ratchet Slot Screwdriver ■
Implant Forceps ■ ■
Surgical Tray ■ ■
Order No. Article
Instruments for implant placement
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:06 Uhr14
15
Drills6
All FRIALIT® Drills are provided with internal irrigation. Please replace thecutting instruments after approximately 20 uses or if they are damaged ordull.
45 – 5102 FRIALIT® Twist Drill D 26 (with 4 Depth Stops)
45 – 5130 FRIALIT® Round Drill6
FRIALIT® Stepped Drill6
45 – 5331 – � D 3.4 universal (with 5 Depth Stops)
45 – 5340 – � D 3.8 universal (with 4 Depth Stops)
45 – 5350 – � D 4.5/L 845 – 5351 – � D 4.5/L 1045 – 5353 – � D 4.5/L 1345 – 5355 – � D 4.5/L 15
45 – 5360 – � D 5.5/L 845 – 5361 – � D 5.5/L 1045 – 5363 – � D 5.5/L 1345 – 5365 – � D 5.5/L 15
45 – 5371 – � D 6.5/L 1045 – 5373 – � D 6.5/L 1345 – 5375 – � D 6.5/L 15
45 – 5101 FRIALIT® Drill Depth Stop Tool6
(two-piece)
FRIALIT® Cortical Drill6
45 – 5349 – � D 3.845 – 5359 – � D 4.545 – 5369 – � D 5.545 – 5379 – � D 6.5
The FRIALIT® Cortical Drill is used to prepare the coronal section of the implantsite in very dense cortical bone.
45 – 5280 FRIADENT® Drill Cleaning Instrument6
91 – 0003 FRIADENT® Drill Extension6
90 – 5042 FRIOS® Contra-angle Handpiece 20:1 Irrigation Tube
90 – 5043 Long Internal Irrigation Tube (for Drill Extension)
The drill extension must always be used with the long internal irrigation tube.
Order No. Article
FRIA
LIT®
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:06 Uhr15
16
FRIALIT BoneCondenser
FRIALIT® BoneCondenser can be used in reduced bone quality to condensethe lateral and apical bone of the implant site. The improved bone qualityand quantity increases implant primary stability.
FRIALIT Instrument Set BoneCondenser, straightwith tray
45 – 8550 � � Instruments Set for diameter D 3.8 – D 4.5(surgical tray with six instruments)
45 – 8560 � � � Instruments Set for diameter D 3.8 – D 5.5(surgical tray with nine instruments)
45 – 8570 � � � � Instruments Set for diameter D 3.8 – D 6.5(surgical tray with twelve instruments)
FRIALIT® BoneCondenser, straight25/6
45 – 5402 – � D 2.045 – 5403 – � D 3.045 – 5440 – � D 3.8
45 – 5451 – � D 4.5 /L 1045 – 5453 – � D 4.5 /L 1345 – 5455 – � D 4.5 /L 15
45 – 5461 – � D 5.5 /L 1045 – 5463 – � D 5.5 /L 1345 – 5465 – � D 5.5 /L 15
45 – 5471 – � D 6.5 /L 1045 – 5473 – � D 6.5 /L 1345 – 5475 – � D 6.5 /L 15
FRIALIT® Instrument Set BoneCondenser, angledwith tray
45 – 8950 � � Instruments Set for diameter D 3.8 – D 4.5(surgical tray with six instruments)
45 – 8960 � � � Instruments Set for diameter D 3.8 – D 5.5(surgical tray with nine instruments)
45 – 8970 � � � � Instruments Set for diameter D 3.8 – D 6.5(surgical tray with twelve instruments)
Order No. Article
Instruments for implant placement
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:06 Uhr16
17
FRIALIT® BoneCondenser, angled25/6
45 – 5902 – � D 2.045 – 5903 – � D 3.045 – 5940 – � D 3.8
45 – 5951 – � D 4.5 /L 1045 – 5953 – � D 4.5 /L 1345 – 5955 – � D 4.5 /L 15
45 – 5961 – � D 5.5 /L 1045 – 5963 – � D 5.5 /L 1345 – 5965 – � D 5.5 /L 15
45 – 5971 – � D 6.5 /L 1045 – 5973 – � D 6.5 /L 1345 – 5975 – � D 6.5 /L 15
The angled FRIALIT® BoneCondenser are used when limited space isavailable and for the posterior region.
48 – 0060 FRIALIT® BoneCondenser Tray5/6/26 (empty)
FRIALIT® BoneExpander
FRIALIT® BoneExpander are used for the local expansion of the narrowatrophied jaw.
45 – 8870 FRIALIT® Instrument Set BoneExpanderwith tray� � � � Instruments Set for diameter D 3.8 – D 6.5(surgical tray with twelve instruments)
FRIALIT® BoneExpander25/6
45 – 5802 – � D 2.045 – 5803 – � D 3.045 – 5840 – � D 3.8
45 – 5851 – � D 4.5 /L 1045 – 5853 – � D 4.5 /L 1345 – 5855 – � D 4.5 /L 15
45 – 5861 – � D 5.5 /L 1045 – 5863 – � D 5.5 /L 1345 – 5865 – � D 5.5 /L 15
45 – 5871 – � D 6.5 /L 1045 – 5873 – � D 6.5 /L 1345 – 5875 – � D 6.5 /L 15
48 – 0050 FRIALIT® BoneExpander Tray5/6/26 (empty)
FRIA
LIT®
Order No. Article
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:06 Uhr17
18
Other instruments
45 – 5106 FRIADENT® Paralleling Pin2
45 – 5709 FRIADENT® Ratchet6, without inserts
45 – 5711 FRIADENT® Ratchet Insert for Implant Driver6
FRIALIT® Ratchet Stepped Screw Implant Driver6
46 – 5512 – 12 mm46 – 5516 – 16 mm46 – 5520 – 20 mm
FRIALIT® Handpiece Stepped Screw Implant Driver4
45 – 5519 – � for D 3.445 – 5510 – � � � � for D 3.8 – D 6.5
FRIADENT® Depth Gauge2
45 – 5104 – D 2.045 – 5100 – D 3.0
Order No. Article
FRIADENT® Periotome
The FRIADENT Periotome is ideally designed for atraumaticresidual root and tooth removal.
45 – 5500 FRIADENT® Periotome Handle6
FRIADENT® Periotome Blade6
45 – 5501 – P 1 (straight, wide)45 – 5502 – P 2 (straight, narrow)45 – 5503 – P 3 (angled, narrow)
Instruments for implant placement
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:06 Uhr18
19
FRIADENT® Handpiece Hex Driver6
45 – 5651 – width 0.9 mm
FRIADENT® Handpiece Slot Screwdriver6
45 – 5640 – blade width 2.0 mm
FRIADENT® Ratchet Hex Driver6
with torque limit45 – 5732 – width 0.9 mm/14 Ncm/short45 – 5733 – width 0.9 mm/14 Ncm/long45 – 5734 – width 1.22 mm/24 Ncm/short45 – 5736 – width 1.22 mm/24 Ncm/long
FRIADENT® Ratchet Slot Screwdriver6
with torque limit45 – 5714 – blade width 2.0 mm/14 Ncm/short45 – 5722 – blade width 2.0 mm/14 Ncm/long
FRIADENT® Hex Driver6
without torque limit45 – 5650 – width 0.9 mm
The 0.9 mm FRIADENT® Hex Driver without torque limit is recommended forregions with limited access.
91 – 4510 FRIADENT® Implant Mallet6/20
91 – 4515 FRIADENT® Implant Forceps2 (titanium)
FRIALIT® Trephine Drill6
45 – 5654 – � D 3.445 – 5655 – � D 3.845 – 5656 – � D 4.545 – 5657 – � D 5.545 – 5658 – � D 6.5
FRIA
LIT®
Order No. Article
ArtKat_FX_FRIALIT_1E_rev007 21.06.2007, 11:06 Uhr19
20
XiVE®
XiVE® plus Implants –As simple as possible,as flexible as necessary
The goal of implant dentistry is to make treatmentsimpler, faster and as easy as possible for your patients.The XiVE® implants offer an accelerated procedure withmultiple prosthetic options without requiring expensiveand complicated surgical and laboratory techniques.XiVE® cylindrical screw implants combine increasedprimary stability in all types of bone with a standardizedprosthetic platform including the option of immediateloading. Through its thread design and simplified surgicalprocedure, XiVE® offers an implant for all types of bone.The internal implant-abutment connection, which has beenproven for over 10 years, is fully compatible with theprosthetic components and instruments of FRIALIT®. Thisuniversal prosthetic platform technology greatly simplifieslife for the restorative dentist.
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:10 Uhr20
21
Indications
Cases:■ with atrophied ridges where augmentation is not
desired or indicated■ multiple implant restorations in posterior regions■ where a cylindrical implant design is advantageous –
particularly in the lateral region■ where a subgingival and/or a transgingival implant
design is indicated■ with limited interproximal space: narrowest implant
diameter = 3.0 mm■ where the local bone must be used to the maximum
possible extent: implant lengths available range from8 to 18 mm
■ requiring increased primary stability for early orimmediate implant function
■ when temporary and definitive components are neededfor simple and fast prosthetic restoration
Macro-design
The cylinder-shaped design for internal condensation ofthe peri-implant bone prevents trauma and increasesprimary stability of implants, even in spongy bone.
Micro-design
The innovative thread design of XiVE® screw implantscombined with the bone-class-specific preparation of theimplant site provides torque stabilization in all bonequalities.
Nano-design
Growth-activating FRIADENT® plus surface. Screw implantwith trimodal surface morphology providing an idealenvironment for functional adaptation of epithelium,connective tissue and bone.
Implant diameters
XiV
E®X
iVE®
TG
D 3.0 D 3.4 D 3.8 D 4.5 D 5.5
XiVE® S � � � � �
XiVE® TG � � �
Article overviewXiVE® TG seepage 66
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:10 Uhr21
22
Pre-surgical planning
Try-in Abutments
Gingival height, angle and the correct position of the horizontal screw (GH 2)for FRIADENT® abutments can easily and quickly be determined with theFRIADENT® Select Try-in Abutments.
FRIADENT® Select Try-in Abutments2
45 – 2119 – � D 3.0/A 0 (straight)45 – 2120 – � D 3.4/A 0 (straight)45 – 2121 – � D 3.8/A 0 (straight)45 – 2122 – � D 4.5/A 0 (straight)45 – 2123 – � D 5.5/A 0 (straight)45 – 2219 – � D 3.0/A 15 (angled 15°)45 – 2220 – � D 3.4/A 15 (angled 15°)45 – 2221 – � D 3.8/A 15 (angled 15°)
Sleeves
FRIADENT® Select Sleeves allow for an exact transfer of the pre-prostheticplanning to the clinical situation.
FRIADENT® Select Sleeves2
without pin
45 – 5025 – � D 3.045 – 5035 – � D 3.445 – 5045 – � D 3.845 – 5055 – � D 4.545 – 5065 – � D 5.5
91 – 4502 FRIADENT® Khoury Drill Guide Pin2
Order No. Article
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:10 Uhr22
23
Try-in Implants
With XiVE® Select Try-in Implants you can verify implant position, implantaxis and the implant position in relation to the bone crest during surgery. Thethickness of the soft tissue can be measured.
26 – 1510 XiVE® Depth Gauge2 D 2.0
26 – 1500 XiVE® Select Basic Set Try-in ImplantThe Basic Set contains one XiVE® Select Try-in Implantper implant diameter (D 3.0 – D 5.5).
XiVE® Select Try-in Implant2
26 – 1520 – � D 3.026 – 1530 – � D 3.426 – 1540 – � D 3.826 – 1550 – � D 4.526 – 1560 – � D 5.5
Others
49 – 1211 FRIADENT® Radiographic Balls for pre-surgical planning6
(Ø 5 mm), 12 pieces
26 – 9020 XiVE® Radiographic Template (subgingival)
25 – 5206 XiVE® TG Radiographic Template (transgingival)
XiV
E®
Order No. Article
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:10 Uhr23
24
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:10 Uhr24
25
Implant placement
FRIADENT® sterile packagingfor screw implants
All FRIADENT® screw implants are packaged in gamma-sterilized, sealed transparent double vials with color-coded caps.
■ Transparent outer vial –to see the content
■ Color-coded cap displaying the implant length –for clear identification
■ Sterile inner vial with implant retaining stopper –for fast and safe no-touch placement of implants
■ Peel-off labels –for a reliable documentation
FRIADENT® sterile packagingfor XiVE® S plus Screw Implants
XiV
E®
No-touch insertion XiVE® S plusScrew Implant
1. Remove the outer vial cap (non sterile) anddrop the sterile inner vial onto the surgical tray.
4. Remove the implantwithout touching the innervial.
5. By doing so, the implantholder falls apart in twohalves.
2. Remove the siliconestopper from the inner vial.
The implant cover screw islocated in the siliconestopper of the inner vial.
3. Place the XiVE® Ratchetor Handpiece ImplantDriver D 3.4/TempBaseinto the internal hex of theFRIADENT® TempBase.
Outer vial(non-sterile)
Inner vial (sterile):contains implant
and TempBase(pre-mounted to
implant)
Retaining stopper:contains implant
cover screw
Implant holder
The undamaged label clearly indicates that thesterile package has not been opened and thus
product sterility.
6. Insert the XiVE® S plus Screw Implant.Please follow the instructions for use.
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:10 Uhr25
26
Implant placement
Implants (sterile)
XiVE® S plus Screw ImplantContent: Screw Implant2, TempBase2,Cover Screw2
26 – 1422 – � D 3.0/L 1126 – 1423 – � D 3.0/L 1326 – 1425 – � D 3.0/L 15
26 – 1431 – � D 3.4/L 9,526 – 1432 – � D 3.4/L 1126 – 1433 – � D 3.4/L 1326 – 1435 – � D 3.4/L 1526 – 1438 – � D 3.4/L 18
26 – 1440 – � D 3.8/L 826 – 1441 – � D 3.8/L 9,526 – 1442 – � D 3.8/L 1126 – 1443 – � D 3.8/L 1326 – 1445 – � D 3.8/L 1526 – 1448 – � D 3.8/L 18
26 – 1450 – � D 4.5/L 826 – 1451 – � D 4.5/L 9,526 – 1452 – � D 4.5/L 1126 – 1453 – � D 4.5/L 1326 – 1455 – � D 4.5/L 1526 – 1458 – � D 4.5/L 18
26 – 1460 – � D 5.5/L 826 – 1461 – � D 5.5/L 9,526 – 1462 – � D 5.5/L 1126 – 1463 – � D 5.5/L 1326 – 1465 – � D 5.5/L 15
All XiVE® S Screw Implants are packaged with the FRIADENT® TempBase formounting the implant driver.
To rotate the XiVE® S Screw Implant into place, use the XiVE® Driver for Ratchetor Handpiece (see page 36). Once the implant is seated, the TempBaseRetaining Screw is loosened with the 0.9 mm FRIADENT® Hex Driver. Then theTempBase removed.The Cover Screw for XiVE® S Screw Implants is located in the silicone stopperof the inner vial.The Cover Screws are threaded in with the 0.9 mm FRIADENT® Hex Driver.
Order No. Article
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:10 Uhr26
27
FRIADENT® TempBase
The FRIADENT® TempBase serves as implant holder and placement head.It is included in the XiVE® S plus Screw Implant.
In addition, with the FRIADENT® TempBase Cap (please order separately) theTempBase can be used for■ an immediate registration to fabricate a temporary during the healingperiod■ an immediate provisional restoration (single tooth or multiple implantprovisional).
FRIADENT® TempBasewith Retaining Screw TempBase
46 – 1220 – � D 3.0 4
46 – 1230 – � D 3.4 4
46 – 1240 – � D 3.8 4
46 – 1250 – � D 4.5 4
46 – 1260 – � D 5.5 4
FRIADENT® TempBase Cap28
46 – 1235 – � � � D 3.0 and D 3.846 – 1255 – � D 4.546 – 1265 – � D 5.5
FRIADENT® Retaining Screw TempBase4
46 – 1279 – � D 3.046 – 1280 – � � � � D 3.4 – D 5.5
FRIADENT® Cover Screw for Implants2
45 – 1120 – � D 3.045 – 1130 – � D 3.445 – 1140 – � D 3.845 – 1150 – � D 4.545 – 1160 – � D 5.5
XiV
E®
Order No. Article
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:10 Uhr27
28
0,5 mm
18 mm
15 mm13 mm11 mm9,5 mm
8 mm
Crestal preparationto achieve the internal condensation effect:XiVE® Twist Drill crestal
The crestal drilling varies between 2 and 6 mmbased on the bone quality. Thus, an optimalprimary stability of the implant in all types ofbone is achieved.
Instruments for implant placement
XiVE® S plusall implants
D 3.0
XiVE® S plus andXiVE® TG plusall implants
D 3.4
XiVE® S plus andXiVE® TG plusall implants
D 3.8
XiVE® S plus andXiVE® TG plusall implants
D 4.5
XiVE® S plusall implants
D 5.5
XiVE®
Twist Drillposterioror anteriorD 2.0
XiVE®
RoundDrill
A successful implant placement requires precise andcareful implant site preparation. Therefore, please followour recommendations for drilling exactly.
Pilot hole:XiVE® D 2.0 Twist Drill (posterior or anterior)XiVE® Twist Drills and Twist Drills crestal are used at800 rpm. During the preparation make sure drills areadequately internally and externally irrigated. Optimumflow volume is guaranteed if separate sources are usedfor internal and external irrigation.
Marking: XiVE® Round Drill
Preparation of the implant site:XiVE® Twist Drill (posterior or anterior),starting with D 3.0 and increasing in diameter until thefinal implant diameter is reached.
The XiVE® drill sequence
Twist Drillanterior
Twist Drillposterior
XiVE® SL 13
XiVE® TGL 13
Pre-tapping the implant thread:In very cortical bone, pre-tapping of the implant site at15 rpm is required in the crestal area after the initial6 mm deep preparation. The XiVE® Tap can be used toreduce the crestal torque achieved during insertion ofimplants.
Pre-tapping the implant sitein type I bone
Bone D IV:2 mm
Bone D I – D III:up to 6 mm
6 mm2 mm
Crestal depth preparation
ArtKat_FX_XiVE_2E_rev007 22.06.2007, 9:43 Uhr28
29
XiVE®
Twist Drillposterioror anteriorD 3.0
XiVE®
Twist Drillposterioror anteriorD 3.4
XiVE®
Twist Drillposterioror anteriorD 3.8
XiVE®
Twist Drillposterioror anteriorD 4.5
XiVE®
Twist Drillposterior oranteriorD 5.5
XiVE®
Twist DrillcrestalD 3.0
XiVE®
Twist DrillcrestalD 3.4
XiVE®
Twist DrillcrestalD 3.8
XiVE®
Twist DrillcrestalD 4.5
XiVE®
Twist DrillcrestalD 5.5
XiVE®
TapD 3.0
XiVE®
TapD 3.4
XiVE®
TapD 3.8
XiVE®
TapD 4.5
XiVE®
TapD 5.5
XiV
E®
XiVE® BoneCondenser:In cases of poor bone quality, XiVE® BoneCondensers canbe used for lateral and apical implant site condensation.This improvement of bone quality and quantity enhancesprimary implant stabilization.
For type Ibone
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:11 Uhr29
30
Instruments for implant placement
XiVE® Instrument Sets Surgery
The XiVE® Instrument Sets Surgery contain the instrumentsrequired for implant placement.The kits are supplied in the XiVE® Surgical Tray.
26 – 8000 XiVE® Expert Set Surgery
26 – 8005 XiVE® Standard Set Surgery
Radiographic Balls for pre-surgical planning 5 5
XiVE® S Radiographic template 1 1XiVE® TG Radiographic template 1 1
FRIADENT® Select Try-in Abutment D 3.0/A 0 1 –FRIADENT® Select Try-in Abutment D 3.4/A 0 1 –FRIADENT® Select Try-in Abutment D 3.8/A 0 1 –FRIADENT® Select Try-in Abutment D 4.5/A 0 1 –FRIADENT® Select Try-in Abutment D 5.5/A 0 1 –FRIADENT® Select Try-in Abutment D 3.0/A 15 1 –FRIADENT® Select Try-in Abutment D 3.4/A 15 1 –FRIADENT® Select Try-in Abutment D 3.8/A 15 1 –
Depth Gauge D 2.0 3 3
XiVE® Select Try-in Implant D 3.0 1 –XiVE® Select Try-in Implant D 3.4 1 –XiVE® Select Try-in Implant D 3.8 1 –XiVE® Select Try-in Implant D 4.5 1 –XiVE® Select Try-in Implant D 5.5 1 –
Twist Drill posterior D 2.0/L 8–15 1 1Twist Drill anterior D 2.0/L 8–18 1 –
Round Drill 1 1
Twist Drill posterior D 3.0/L 8–15 1 1Twist Drill posterior D 3.4/L 8–15 1 1Twist Drill posterior D 3.8/L 8–15 1 1Twist Drill posterior D 4.5/L 8–15 1 1Twist Drill posterior D 5.5/L 8–15 1 1
Twist Drill anterior D 3.0/L 8–18 1 –Twist Drill anterior D 3.4/L 8–18 1 –Twist Drill anterior D 3.8/L 8–18 1 –Twist Drill anterior D 4.5/L 8–18 1 –Twist Drill anterior D 5.5/L 8–18 1 –
Twist Drill crestal D 3.0 1 1Twist Drill crestal D 3.4 1 1Twist Drill crestal D 3.8 1 1Twist Drill crestal D 4.5 1 1Twist Drill crestal D 5.5 1 1
XiVE® Tap Set 1 1Drill Extension 1 1
Long Internal Irrigation Tube 1 1Drill Cleaning Instrument 1 1
Ratchet Implant Driver posterior for Screw Implants D 3.0 1 1Ratchet Implant Driver posterior for Screw Implants and TempBase D 3.4–D 6.5 1 1Ratchet Implant Driver anterior for Screw Implants D 3.0 1 1Ratchet Implant Driver anterior for Screw Implants and TempBase D 3.4–D 6.5 1 1Handpiece Implant Driver posterior for Screw Implants D 3.0 1 1Handpiece Implant Driver posterior for Screw Implants and TempBase D 3.4 1 1Handpiece Implant Driver posterior for Screw Implants D 3.8–D 6.5 1 1Handpiece Implant Driver anterior for Screw Implants D 3.0 1 1Handpiece Implant Driver anterior for Screw Implants and TempBase D 3.4 1 1Handpiece Implant Driver anterior for Screw Implants D 3.8–D 6.5 1 1Ratchet Implant Driver TG 1 1Handpiece Implant Driver TG 1 1
FRIADENT® Ratchet 1 1FRIADENT® Ratchet Insert for Implant Driver 1 1
Handpiece Hex Driver 0.9 mm/short 1 1Handpiece Hex Driver 0.9 mm/long 1 1Handpiece Hex Driver 1.22 mm/short 1 1Handpiece Hex Driver 1.22 mm/long 1 1Handle for Contra-angle Hex Driver 1 1Ratchet Hex Driver 0.9 mm/short 1 1Ratchet Hex Driver 0.9 mm/long 1 1Ratchet Hex Driver 1.22 mm/short 1 1Ratchet Hex Driver 1.22 mm/long 1 1
Implant Forceps 1 1XiVE® Surgical Tray 1 1
Contents: Expert Standard Set Set
Contents: Expert Standard Set Set
Order No. Article
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:11 Uhr30
31
XiVE® Security Kits
The XiVE® Security Kits contain all depth stops requiredfor using the universal XiVE® Twist Drills.The kits are supplied in the XiVE® Security Tray.
26 – 1200 XiVE® Expert Security Kit (posterior/anterior)
26 – 1205 XiVE® Standard Security Kit (posterior only)
Contents: ExpertSet StandardSet
Depth Stop posterior D 2.0–D 3.0/L 8 1 1Depth Stop posterior D 2.0–D 3.0/L 9.5 1 1Depth Stop posterior D 2.0–D 3.0/L 11 1 1Depth Stop posterior D 2.0–D 3.0/L 13 1 1Depth Stop posterior D 2.0–D 3.0/L 15 1 1
Depth Stop posterior D 3.4–D 3.8/L 8 1 1Depth Stop posterior D 3.4–D 3.8/L 9.5 1 1Depth Stop posterior D 3.4–D 3.8/L 11 1 1Depth Stop posterior D 3.4–D 3.8/L 13 1 1Depth Stop posterior D 3.4–D 3.8/L 15 1 1
Depth Stop posterior D 4.5–D 5.5/L 8 1 1Depth Stop posterior D 4.5–D 5.5/L 9.5 1 1Depth Stop posterior D 4.5–D 5.5/L 11 1 1Depth Stop posterior D 4.5–D 5.5/L 13 1 1Depth Stop posterior D 4.5–D 5.5/L 15 1 1
Depth Stop anterior D 2.0–D 3.0/L 8 1 –Depth Stop anterior D 2.0–D 3.0/L 9.5 1 –Depth Stop anterior D 2.0–D 3.0/L 11 1 –Depth Stop anterior D 2.0–D 3.0/L 13 1 –Depth Stop anterior D 2.0–D 3.0/L 15 1 –Depth Stop anterior D 2.0–D 3.0/L 18 1 –
Depth Stop anterior D 3.4–D 3.8/L 8 1 –Depth Stop anterior D 3.4–D 3.8/L 9.5 1 –Depth Stop anterior D 3.4–D 3.8/L 11 1 –Depth Stop anterior D 3.4–D 3.8/L 13 1 –Depth Stop anterior D 3.4–D 3.8/L 15 1 –Depth Stop anterior D 3.4–D 3.8/L 18 1 –
Depth Stop anterior D 4.5–D 5.5/L 8 1 –Depth Stop anterior D 4.5–D 5.5/L 9.5 1 –Depth Stop anterior D 4.5–D 5.5/L 11 1 –Depth Stop anterior D 4.5–D 5.5/L 13 1 –Depth Stop anterior D 4.5–D 5.5/L 15 1 –Depth Stop anterior D 4.5–D 5.5/L 18 1 –
XiVE® Security Kit Tray 1 1
The XiVE® Depth Stops are mounted and removed from the XiVE® drillmanually, over the cutting end. No additional instruments are necessary.
26 – 8010 XiVE® Surgical Tray (empty)
26 – 1390 XiVE® Security Kit Tray (empty)
XiV
E®
Order No. Article
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:11 Uhr31
32
Instruments for Implant Placement
Order No. Article
XiVE® Single-patient Drills (single articles)
26 – 1015 – � D 2.0/L 8 – L 15
26 – 1025 – � D 3.0/L 8 – L 15
26 – 1035 – � D 3.4/L 8 – L 15
26 – 1045 – � D 3.8/L 8 – L 15
26 – 1055 – � D 4.5/L 8 – L 15
26 – 1065 – � D 5.5/L 8 – L 15
Article sets
The XiVE® Single-patient Drill Sets include all twist drills required for implant site preparation ofthe appropriate implant diameter.Once this diameter has been reached, the XiVE® Twist Drill crestal has to be used additionally.
XiVE® Single-patient Drill Set26 – 3025 – � D 3.0/L 8 – L 15
XiVE® Single-patient Drill Set26 – 3035 – � D 3.4/L 8 – L 15
XiVE® Single-patient Drill Set26 – 3045 – � D 3.8/L 8 – L 15
XiVE® Single-patient Drill Set26 – 3055 – � D 4.5/L 8 – L 15
XiVE® Single-patient Drill Set26 – 3065 – � D 5.5/L 8 – L 15
Drills
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:11 Uhr32
33
All XiVE® Twist Drills are available in one length. The drills are adjusted to thedesired implant length by using the respective XiVE® Depth Stops.The XiVE® Expert Security Kit contains one complete set of depth stops for theXiVE® posterior and anterior Twist Drills. The XiVE® Standard Security Kitincludes only the depth stops for the posterior Twist Drills (see page 31).
All XiVE® Drills are provided with internal irrigation. Please replace the cuttinginstruments after approximately 20 uses or if they are damaged or dull.
26 – 1115 XiVE® Twist Drill posterior6 D 2.0/L 8–1526 – 1118 XiVE® Twist Drill anterior6 D 2.0/L 8–18
26 – 1110 XiVE® Round Drill6
XiVE® Twist Drill posterior6
26 – 1125 – � D 3.0/L 8–1526 – 1135 – � D 3.4/L 8–1526 – 1145 – � D 3.8/L 8–1526 – 1155 – ● D 4.5/L 8–1526 – 1165 – � D 5.5/L 8–15
XiVE® Twist Drill anterior6
26 – 1128 – � D 3.0/L 8–1826 – 1138 – � D 3.4/L 8–1826 – 1148 – � D 3.8/L 8–1826 – 1158 – ● D 4.5/L 8–1826 – 1168 – � D 5.5/L 8–18
The XiVE® Twist Drills posterior andanterior are provided with markinggrooves for clear distinction:
XiVE® Twist Drill crestal6
26 – 1120 – � D 3.026 – 1130 – � D 3.426 – 1140 – � D 3.826 – 1150 – ● D 4.526 – 1160 – � D 5.5
Once the appropriate diameter has been reached, the crestal preparationleads to an internal condensation of the implant site and thus increasesprimary stability. The Twist Drill crestal always has to be used.
In type I bone, pre-tapping of the implant threads is required in the crestalarea after crestal preparation. Therefore, the XiVE® Tap (see page 35) has tobe used.
XiV
E®
Order No. Article
posterior: anterior:1 groove 2 grooves
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:11 Uhr33
34
Instruments for implant placement
Order No. Article
Drill Depth Stops
XiVE® Depth Stop posterior6
26 – 1210 – � � D 2.0 – 3.0/L 826 – 1211 – � � D 2.0 – 3.0/L 9.526 – 1212 – � � D 2.0 – 3.0/L 1126 – 1213 – � � D 2.0 – 3.0/L 1326 – 1215 – � � D 2.0 – 3.0/L 15
26 – 1230 – � � D 3.4 – 3.8/L 826 – 1231 – � � D 3.4 – 3.8/L 9.526 – 1232 – � � D 3.4 – 3.8/L 1126 – 1233 – � � D 3.4 – 3.8/L 1326 – 1235 – � � D 3.4 – 3.8/L 15
26 – 1250 – � � D 4.5 – 5.5/L 826 – 1251 – � � D 4.5 – 5.5/L 9.526 – 1252 – � � D 4.5 – 5.5/L 1126 – 1253 – � � D 4.5 – 5.5/L 1326 – 1255 – � � D 4.5 – 5.5/L 15
XiVE® Depth Stop anterior6
26 – 1310 – � � D 2.0 – 3.0/L 826 – 1311 – � � D 2.0 – 3.0/L 9.526 – 1312 – � � D 2.0 – 3.0/L 1126 – 1313 – � � D 2.0 – 3.0/L 1326 – 1315 – � � D 2.0 – 3.0/L 1526 – 1318 – � � D 2.0 – 3.0/L 18
26 – 1330 – � � D 3.4 – 3.8/L 826 – 1331 – � � D 3.4 – 3.8/L 9.526 – 1332 – � � D 3.4 – 3.8/L 1126 – 1333 – � � D 3.4 – 3.8/L 1326 – 1335 – � � D 3.4 – 3.8/L 1526 – 1338 – � � D 3.4 – 3.8/L 18
26 – 1350 – � � D 4.5 – 5.5/L 826 – 1351 – � � D 4.5 – 5.5/L 9.526 – 1352 – � � D 4.5 – 5.5/L 1126 – 1353 – � � D 4.5 – 5.5/L 1326 – 1355 – � � D 4.5 – 5.5/L 1526 – 1358 – � � D 4.5 – 5.5/L 18
The XiVE® Depth Stops posterior and anterior are also providedwith marking grooves for clear distinction.
The XiVE® Depth Stops are mounted and removed from the XiVE® Drillmanually, over the cutting end. No additional instruments are necessary.
posterior: anterior:1 groove 2 grooves
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:11 Uhr34
35
XiV
E
45 – 5280 FRIADENT® Drill Cleaning Instrument6
91 – 0003 FRIADENT® Drill Extension6
90 – 5042 FRIOS® Contra-angle Handpiece 20:1 Irrigation Tube
90 – 5043 Long Internal Irrigation Tube (for Drill Extension)
The drill extension must always be used with the long internal irrigation tube.
Taps
In very cortical bone, pre-tapping of the implant site is required in thecrestal area after the initial 6 mm deep preparation. The XiVE® Tap canbe used to reduce the crestal torque achieved during insertion of implants.
26 – 1180 XiVE® Tap Set4
one tap per diameter D 3.0 – D 5.5
XiVE® Tap4
26 – 1121 – � D 3.026 – 1131 – � D 3.426 – 1141 – � D 3.826 – 1151 – ● D 4.526 – 1161 – � D 5.5
The XiVE® Taps are used with the FRIADENT® Ratchet or Handpiece ImplantDriver D 3.4/TempBase.
XiV
E®
Order No. Article
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:11 Uhr35
36
Order No. Article
Instruments for implant placement
XiVE® BoneCondenser
XiVE® BoneCondenser can be used in reduced bone quality to condense thelateral and apical bone of the implant site. The improved bone quality andquantity increases implant primary stability.
All XiVE® BoneCondenser are available in one length. Depth marks at theworking tip indicate the preparation depth.
26 – 1600 � � � � � XiVE® Instrument Set BoneCondenserstraight and angled(tray with all XiVE® BoneCondensers, straight and angled)
26 – 1603 � � � � � XiVE® Instrument Set BoneCondenserstraight(tray with all XiVE® BoneCondensers, straight)
26 – 1606 � � � � � XiVE® Instrument Set BoneCondenserangled(tray with all XiVE® BoneCondensers, angled)
XiVE® BoneCondenser, straight25/6
26 – 1610 – � D 2.026 – 1620 – � D 3.026 – 1630 – � D 3.426 – 1640 – � D 3.826 – 1650 – ● D 4.526 – 1660 – � D 5.5
XiVE® BoneCondenser, angled25/6
26 – 1615 – � D 2.026 – 1625 – � D 3.026 – 1635 – � D 3.426 – 1645 – � D 3.826 – 1655 – ● D 4.526 – 1665 – � D 5.5
The angled XiVE® BoneCondenser are used when limited space is availableand for the posterior region.
26 – 1790 XiVE® BoneCondenser Tray5/6/26 (empty)
Other Instruments
26 – 1510 XiVE® Depth Gauge2 D 2.0
45 – 5709 FRIADENT® Ratchet6, without insert
45 – 5711 FRIADENT® Ratchet Insert for Implant Driver6
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:11 Uhr36
37
XiV
E®
Order No. Article
FRIADENT® Ratchet Implant Driver2
46 – 5810 – � posterior for implants D 3.046 – 5912 – � posterior for implants D 3.4 and TempBase46 – 5820 – � anterior for implants D 3.046 – 5922 – � anterior for implants D 3.4 and TempBase
Please use the FRIALIT® Implant Drivers 46 – 5512 and 46 – 5516(see page 18) when inserting XiVE® S Screw Implants D 3.8 – D 5.5without TempBase.
FRIADENT® Handpiece Implant Driver4
46 – 5830 – � posterior for implants D 3.046 – 5932 – � posterior for implants D 3.4 and TempBase46 – 5834 – � � � � posterior for implants D 3.8 – D 6.546 – 5840 – � anterior for implants D 3.046 – 5942 – � anterior for implants D 3.4 and TempBase46 – 5844 – � � � � anterior for implants D 3.8 – D 6.5
FRIADENT® Ratchet Hex Driver6
with torque limit45 – 5732 – width 0.9 mm/14 Ncm/short45 – 5733 – width 0.9 mm/14 Ncm/long45 – 5734 – width 1.22 mm/24 Ncm/short45 – 5736 – width 1.22 mm/24 Ncm/long
FRIADENT® Ratchet Slot Screwdriver6
with torque limit45 – 5714 – blade width 2.0 mm/14 Ncm/short45 – 5722 – blade width 2.0 mm/14 Ncm/long
FRIADENT® Handpiece Hex Driver6
46 – 5710 – width 0.9 mm/short46 – 5720 – width 0.9 mm/long46 – 5711 – width 1.22 mm/short46 – 5721 – width 1.22 mm/long
FRIADENT® Handpiece Slot Driver6
46 – 5712 – blade width 2.0 mm/short46 – 5722 – blade width 2.0 mm/long
46 – 5880 FRIADENT Implant Driver Manual Long
XiVE® Trephine Drill
26 – 1129 – � D 3.0/L 8–1826 – 1139 – � D 3.4/L 8–1826 – 1149 – � D 3.8/L 8–1826 – 1159 – ● D 4.5/L 8–1826 – 1169 – � D 5.5/L 8–18
ArtKat_FX_XiVE_2E_rev007 21.06.2007, 11:11 Uhr37
38
FRIADENT®
Prosthetics FRIADENT® Prostheticsfor FRIALIT® and XiVE® S –Universal compatibility
The FRIALIT® and XiVE® implant options cover allindications. From the top of the implant, the prostheticprocedure should be as simple as possible. Therefore,DENTSPLY Friadent provides the unique concept ofplatform technology:
Identical implant-abutment connection
Surgical versatility with unlimited prosthetic flexibility isprovided through the universal internal hex connection.A patented1 connection that has been proven over morethan10 years of clinical use2
for all prosthetic concepts.
1 Patent EP 0438 048 and US 4, 960 381, Internal Hex US Patent 5, 199 8732 Möllersten et al., Comparison of strength and failure mode of seven implant systems: An in vitro test. J Prosthet Dent 1997; 78:582-91
FRIADENT®
ProTectFRIADENT®
CoverScrew
FRIADENT®
GingivaFormer
FRIADENT®
Transfer Copingwith
TransferCap
FRIADENT®
EstheticBasestraight and angled,
Horizontal orTransverse Screw
optional
FRIALIT®
ImplantsXiVE® SImplants
FRIADENT®
EsthetiCap
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:18 Uhr38
39
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
Implant diameters/prosthetic diameters
FRIADENT®
CERCON®
Abutment
FRIADENT®
AuroBaseFRIADENT®
TelescopicAbutment
FRIADENT®
Ball and SocketAttachment
FRIADENT®
MP CoverScrew
FRIADENT®
MP Transfer orPickUp Impression
Coping
FRIADENT®
MP Abutmentwith Bar Coping
or WaxingSleeve
D 3.0 D 3.4 D 3.8 D 4.5 D 5.5 D 6.5
FRIALIT® � � � � �
XiVE® S � � � � �
FRIADENT®
CeraBase
XiVE® TG implants:implant-abutment-
connection compatiblewith FRIADENT®
MP Abutment
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:19 Uhr39
40
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:19 Uhr40
41
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
At uncovery, based on the indication, you will decide whether to fabricate thesuperstructure■ from the implant level or■ from the gingival level (MP Abutment).
FRIADENT® Prosthetics
Single Crowns Bridges Overdentures
FRIADENT® AuroBase
Telescopic Abutment
Telescopic Abutment
FRIADENT® MP Abutment(Bridge) with Castable
or Cast-to WaxingSleeve
FRIADENT® MPAbutment (Bar) withGold, Titanium or
Castable Bar Coping
at implant level
pages 43 – 54
at gingival level(MP Abutment)
pages 55 – 61
Impression Making
FRIADENT® EstheticBasestraight or angled
FRIADENT®
Transfer Coping(Transfer Technique)
FRIADENT®
Transfer Coping(PickUp Technique)
FRIADENT® MPImpression Coping(Transfer technique)
FRIADENT® MPImpression Coping(PickUp Technique)
FRIADENT® EstheticBasestraight or angled
FRIADENT® MP Abutment
FRIADENT® Attachment
FRIADENT® FRIADENT®
CERCON® CeraBaseCeramic Abutments
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:19 Uhr41
42
Uncovery
Soft Tissue Punches
FRIADENT® Tissue Punch6
45 – 5665 – � D 3.045 – 5666 – � D 3.445 – 5660 – � D 3.845 – 5661 – ● D 4.545 – 5662 – � D 5.545 – 5663 – � D 6.5
BoneProfiler
In case of implants placed subcrestally, new bone can grow over the implantduring the healing phase. With the FRIALIT® BoneProfiler, this bone can beremoved and the Cover Screw uncovered. The geometry of the FRIALIT®
BoneProfiler exactly matches that of the Gingiva Former.
FRIADENT® BoneProfiler6
45 – 5338 – � D 3.445 – 5348 – � D 3.845 – 5358 – ● D 4.545 – 5368 – � D 5.545 – 5378 – � D 6.5
45 – 5300 FRIADENT® Guide Pin for BoneProfiler
45 – 5550 FRIADENT® Soft Tissue Gauge6
Order No. Article
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:19 Uhr42
43
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
Gingiva Formers
FRIADENT® Gingiva Former2
45 – 1421 – � D 3.0/GH 145 – 1422 – � D 3.0/GH 245 – 1423 – � D 3.0/GH 345 – 1425 – � D 3.0/GH 5
45 – 1431 – � D 3.4/GH 145 – 1432 – � D 3.4/GH 245 – 1433 – � D 3.4/GH 345 – 1435 – � D 3.4/GH 5
45 – 1441 – � D 3.8/GH 145 – 1442 – � D 3.8/GH 245 – 1443 – � D 3.8/GH 345 – 1445 – � D 3.8/GH 5
45 – 1451 – ● D 4.5/GH 145 – 1452 – ● D 4.5/GH 245 – 1453 – ● D 4.5/GH 345 – 1455 – ● D 4.5/GH 5
45 – 1461 – � D 5.5/GH 145 – 1462 – � D 5.5/GH 245 – 1463 – � D 5.5/GH 345 – 1465 – � D 5.5/GH 5
The gingiva formers are threaded in with the 0.9 mm FRIADENT Hex Driveror with the blade width 2.0 mm FRIADENT® Slot Screwdriver (see page 64).
Prosthetic fabrication at implant level:
Soft tissue management,provisional restorations
Order No. Article
GH 1
2 mm
3 mm
5 mm
1 mm
GH 2
GH 3
GH 5
Please note:� D 3.0 components (bronze) can only be used for XiVE®.FRIALIT® implants � D 6.5 (green) are restored with � D 5.5 abutments.
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:19 Uhr43
44
FRIADENT® Gingiva Former2 Slim
45 – 1232 – � D 3.4/GH 245 – 1233 – � D 3.4/GH 345 – 1235 – � D 3.4/GH 5
45 – 1242 – � D 3.8/GH 245 – 1243 – � D 3.8/GH 345 – 1245 – � D 3.8/GH 5
45 – 1252 – ● D 4.5/GH 245 – 1253 – ● D 4.5/GH 345 – 1255 – ● D 4.5/GH 5
With the FRIADENT® Gingiva Former Slim a perfect contouring of the softtissue can be achieved in cases with limited mesio-distal space. For makingimpressions, the FRIADENT® Transfer Coping Slim (see page 47) is used.
FRIADENT® Gingiva Former2 Loop
45 – 1333 – � D 3.4/GH 345 – 1335 – � D 3.4/GH 5
45 – 1343 – � D 3.8/GH 345 – 1345 – � D 3.8/GH 5
45 – 1353 – ● D 4.5/GH 345 – 1355 – ● D 4.5/GH 5
45 – 1363 – � D 5.5/GH 345 – 1365 – � D 5.5/GH 5
The FRIADENT® Gingiva Former Loop allows easy securing of suturematerial, thus enabling simple and safe soft tissue surgery.
Order No. Article
Prosthetic fabrication at implant level:
Soft tissue management,provisional restorations
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:19 Uhr44
45
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
Order No. Article
FRIADENT® EsthetiCapwith Screw for EsthetiCap
46 – 1730 – � D 3.4/oval
46 – 1740 – � D 3.8/oval46 – 1745 – � D 3.8/triangular
46 – 1750 – ● D 4.5/oval46 – 1755 – ● D 4.5/triangular
46 – 1760 – � D 5.5/oval46 – 1765 – � D 5.5/triangular
As anatomical gingiva formers, the FRIADENT® EsthetiCap abutments provideperfect anatomical and esthetic peri-implant gingival contours by simplecustomization.
Provisional Restorations
FRIADENT® ProTect Abutment24
with PickUp Guide Pin4
45 – 1530 – � D 3.445 – 1540 – � D 3.845 – 1550 – ● D 4.545 – 1560 – � D 5.5
The PickUp Guide Pin ensures optimum stability for the provisionalabutment.
Please note:� D 3.0 components (bronze) can only be used for XiVE®.FRIALIT® implants � D 6.5 (green) are restored with � D 5.5 abutments.
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:19 Uhr45
46
Prosthetic fabrication at implant level:
Impressions
FRIADENT® Lab Set Transfer ImpressionThe Lab Set Transfer Impression contains Transfer Coping,FRIADENT® TransferCap (D 3.0 – D 5.5), Standard AbutmentScrew (D 3.0 with Abutment Screw D 3.0) and Implant Analog
46 – 8123 – � D 3.0/GH 346 – 8125 – � D 3.0/GH 5
46 – 8133 – � D 3.4/GH 346 – 8135 – � D 3.4/GH 5
46 – 8143 – � D 3.8/GH 346 – 8145 – � D 3.8/GH 5
46 – 8153 – ● D 4.5/GH 346 – 8155 – ● D 4.5/GH 5
46 – 8163 – � D 5.5/GH 346 – 8165 – � D 5.5/GH 5
FRIADENT® Lab Set PickUp ImpressionThe Lab Set PickUp Impression contains Transfer Coping,FRIADENT® TransferCap (D 3.0 – D 5.5), Standard AbutmentScrew (D 3.0 with Abutment Screw D 3.0) and Implant Analog
46 – 8223 – � D 3.0/GH 346 – 8225 – � D 3.0/GH 5
46 – 8233 – � D 3.4/GH 346 – 8235 – � D 3.4/GH 5
46 – 8243 – � D 3.8/GH 346 – 8245 – � D 3.8/GH 5
46 – 8253 – ● D 4.5/GH 346 – 8255 – ● D 4.5/GH 5
46 – 8263 – � D 5.5/GH 346 – 8265 – � D 5.5/GH 5
The Transfer Coping GH 3 is used forgingiva up to 3 mm thick. Please use theTransfer Coping GH 5 for gingiva exceeding3 mm thickness.
Order No. Article
GH 3 GH 5
5 mm3 mm
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:19 Uhr46
47
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
FRIADENT® Transfer Coping (Transfer Technique)with Standard Abutment Screw4 (D 3.0 withAbutment Screw4 D 3.0) and TransferCap20 (D 3.0 – D 5.5)
45 – 1620 – � D 3.0/GH 3 4
45 – 1621 – � D 3.0/GH 5 4
45 – 1630 – � D 3.4/GH 3 4
45 – 1631 – � D 3.4/GH 5 4
45 – 1640 – � D 3.8/GH 3 2
45 – 1641 – � D 3.8/GH 5 2
45 – 1650 – ● D 4.5/GH 3 2
45 – 1651 – ● D 4.5/GH 5 2
45 – 1660 – � D 5.5/GH 3 2
45 – 1661 – � D 5.5/GH 5 2
FRIADENT® Transfer Coping (PickUp Technique)with PickUp Guide Pin4 (D 3.0 with PickUpGuide Pin4 D 3.0) and TransferCap20 (D 3.0 – D 5.5)
45 – 1625 – � D 3.0/GH 3 4
45 – 1622 – � D 3.0/GH 5 4
45 – 1635 – � D 3.4/GH 3 4
45 – 1632 – � D 3.4/GH 5 4
45 – 1645 – � D 3.8/GH 3 2
45 – 1642 – � D 3.8/GH 5 2
45 – 1655 – ● D 4.5/GH 3 2
45 – 1652 – ● D 4.5/GH 5 2
45 – 1665 – � D 5.5/GH 3 2
45 – 1662 – � D 5.5/GH 5 2
FRIADENT® Transfer Coping Slim2
45 – 1239 – � D 3.445 – 1249 – � D 3.845 – 1259 – ● D 4.5
The FRIADENT® Transfer Coping Slim is used if – in cases with limited mesio-distal space – the contouring of the soft tissue has been made with theGingiva Former Slim (see page 44).
Order No. Article
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:19 Uhr47
48
Prosthetic fabrication at implant level:
Impressions
FRIADENT® Transfer Coping Basic2
46 – 1632 – � D 3.446 – 1642 – � D 3.846 – 1652 – ● D 4.546 – 1662 – � D 5.5
The FRIADENT® Transfer Coping Basic is used for simple impression making incases with implant divergencies.
46 – 4304 � FRIADENT® Standard Abutment Screw 4 D 3.045 – 4305 � � � � FRIADENT® Standard Abutment Screw4
46 – 1605 � FRIADENT® PickUp Guide Pin4 D 3.045 – 1615 � � � � FRIADENT® PickUp Guide Pin4
Abutment screws and guide pins are seated with the 0.9 mmFRIADENT® Hex Driver or with the blade width 2.0 mm FRIADENT®
Slot Screwdriver (see page 70).
TransferCaps
FRIADENT® TransferCaps allow for greater precision during impression so thatthe implant inner geometry is transferred with even greater accuracy.The result is the best possible superstructure fit.FRIADENT® TransferCaps are not available for diameter D 6.5.
FRIADENT® Multi-Pack TransferCap20
(3 pieces)
45 – 1629 – � D 3.045 – 1639 – � D 3.445 – 1649 – � D 3.845 – 1659 – ● D 4.545 – 1669 – � D 5.5
Order No. Article
Please note:� D 3.0 components (bronze) can only be used for XiVE®.FRIALIT® implants � D 6.5 (green) are restored with � D 5.5 abutments.
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:19 Uhr48
49
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
FRIADENT® Implant Analog5
45 – 4020 – � D 3.045 – 4030 – � D 3.445 – 4040 – � D 3.845 – 4050 – ● D 4.545 – 4060 – � D 5.545 – 4070 – � D 6.5
Try-in Abutments
Gingival height, angle and the correct position of the horizontal screw (GH 2)for FRIADENT® abutments can easily and quickly be determined with theFRIADENT® Select Try-in Abutments.
FRIADENT® Select Try-in Abutment2
45 – 2119 – � D 3.0/A 0 (straight)45 – 2120 – � D 3.4/A 0 (straight)45 – 2121 – � D 3.8/A 0 (straight)45 – 2122 – � D 4.5/A 0 (straight)45 – 2123 – � D 5.5/A 0 (straight)45 – 2219 – � D 3.0/A 15 (angled 15°)45 – 2220 – � D 3.4/A 15 (angled 15°)45 – 2221 – � D 3.8/A 15 (angled 15°)
FRIADENT® Select Try-in Abutment Multi-Pack2 (3 pieces)
45 – 2193 – � D 3.4/A 0 (straight, 3 pieces)45 – 2194 – � D 3.8/A 0 (straight, 3 pieces)45 – 2195 – � D 4.5/A 0 (straight, 3 pieces)45 – 2196 – � D 5.5/A 0 (straight, 3 pieces)45 – 2293 – � D 3.4/A 15 (angled, 3 pieces)45 – 2294 – � D 3.8/A 15 (angled, 3 pieces)
Prosthetic fabrication from the implant level:
Prosthetics/laboratory
Order No. Article
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:19 Uhr49
50
EstheticBase Abutments
FRIADENT® EstheticBase straight / A 0Screw for EstheticBase4 (D 3.0 with Abutment Screw4 D 3.0)
46 – 2121 – � D 3.0/GH 1 4
46 – 2122 – � D 3.0/GH 2 4
46 – 2123 – � D 3.0/GH 3 4
46 – 2125 – � D 3.0/GH 5 4
46 – 2131 – � D 3.4/GH 1 4
46 – 2132 – � D 3.4/GH 2 4
46 – 2133 – � D 3.4/GH 3 4
46 – 2135 – � D 3.4/GH 5 4
46 – 2141 – � D 3.8/GH 1 2
46 – 2142 – � D 3.8/GH 2 2
46 – 2143 – � D 3.8/GH 3 2
46 – 2145 – � D 3.8/GH 5 2
46 – 2151 – ● D 4.5/GH 1 2
46 – 2152 – ● D 4,5/GH 2 2
46 – 2153 – ● D 4.5/GH 3 2
46 – 2155 – ● D 4.5/GH 5 2
46 – 2161 – � D 5.5/GH 1 2
46 – 2162 – � D 5.5/GH 2 2
46 – 2163 – � D 5.5/GH 3 2
46 – 2165 – � D 5.5/GH 5 2
All FRIADENT® EstheticBase Abutments are provided with a horizontal thread(M 1.4).An additional horizontal or transverse screw set is necessary for horizontallyscrew-retained crowns (see page 52).
We recommend the use of special titanium drills (Gebr. Brasseler, Lemgo orJota Düsseldorf) for preparing the abutments.
Abutment screws
46 – 4304 � FRIADENT® Standard Abutment Screw4 D 3,0
46 – 4305 � � � � FRIADENT® Screw4 for EstheticBase
Abutments for single tooth restorations and bridges
Prosthetic fabrication at implant level:
Prosthetics/laboratory
Order No. Article
GH 11 mm
GH 22 mm
GH 33 mm
GH 55 mm
Please note:� D 3.0 components (bronze) can only be used for XiVE®.FRIALIT® implants � D 6.5 (green) are restored with � D 5.5 abutments.
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:19 Uhr50
51
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
FRIADENT® EstheticBase angled / A 15Screw for EstheticBase4 (D 3.0 with Abutment Screw4 D 3.0)
46 – 2221 – � D 3.0/GH 1 4
46 – 2222 – � D 3.0/GH 2 4
46 – 2223 – � D 3.0/GH 3 4
46 – 2225 – � D 3.0/GH 5 4
46 – 2231 – � D 3.4/GH 1 4
46 – 2232 – � D 3.4/GH 2 4
46 – 2233 – � D 3.4/GH 3 4
46 – 2235 – � D 3.4/GH 5 4
46 – 2241 – � D 3.8/GH 1 2
46 – 2242 – � D 3.8/GH 2 2
46 – 2243 – � D 3.8/GH 3 2
46 – 2245 – � D 3.8/GH 5 2
46 – 2251 – ● D 4.5/GH 1 2
46 – 2252 – ● D 4.5/GH 2 2
46 – 2253 – ● D 4.5/GH 3 2
46 – 2255 – ● D 4.5/GH 5 2
46 – 2261 – � D 5.5/GH 1 2
46 – 2262 – � D 5.5/GH 2 2
46 – 2263 – � D 5.5/GH 3 2
46 – 2265 – � D 5.5/GH 5 2
Horizontal screws
46 – 4403 FRIADENT® Horizontal Screw Set Standardwith Horizontal Screw Standard4 and Horizontal Screw Seat8
46 – 4404 FRIADENT® Horizontal Screw Set Longwith Horizontal Screw Long4 and Horizontal Screw Seat8
46 – 4407 FRIADENT® Transverse Screw Set Standardwith Transversal Screw Standard4 and Horizontal Screw Seat8
46 – 4408 FRIADENT® Transverse Screw Set Longwith Transversal Screw Long4 and Horizontal Screw Seat8
46 – 4401 FRIADENT® Horizontal Screw Standard4
46 – 4402 FRIADENT® Horizontal Screw Long4
46 – 4405 FRIADENT® Transverse Screw Standard4
46 – 4406 FRIADENT® Transverse Screw Long4
45 – 4410 FRIADENT® Horizontal Screw Seat8
Horizontal screws are seated in with the 0.9 mm FRIADENT® Hex Driver(see page 64). Particularly for molars, the use of the Horizontal Screw Setwith a long head is recommended, as the crown usually requires broaderbuccal-lingual width.
Order No. Article
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:19 Uhr51
52
Ceramic Abutments
FRIADENT® CERCON® Abutment32 straight / A 0with Screw
47 – 1141 – � D 3.8/GH1, neutral47 – 2141 – � D 3.8/GH1, dentin47 – 1151 – ● D 4.5/GH1, neutral47 – 2151 – ● D 4.5/GH1, dentin
47 – 1142 – � D 3.8/GH2, neutral47 – 2142 – � D 3.8/GH2, dentin47 – 1152 – ● D 4.5/GH2, neutral47 – 2152 – ● D 4.5/GH2, dentin
FRIADENT® CERCON® Abutment32 angled / A 15with Screw
47 – 1241 – � D 3.8/GH1, neutral47 – 2241 – � D 3.8/GH1, dentin47 – 1251 – ● D 4.5/GH1, neutral47 – 2251 – ● D 4.5/GH1, dentin
47 – 1242 – � D 3.8/GH2, neutral47 – 2242 – � D 3.8/GH2, dentin47 – 1252 – ● D 4.5/GH2, neutral47 – 2252 – ● D 4.5/GH2, dentin
We recommend using the ceramic-line Shaping Set of DeguDent forprepping the FRIADENT® CERCON® Abutments. The grinding process of theCERCON® Abutments requires irrigation.Please note that the indication is restricted to the front tooth region.
FRIADENT® CeraBase Abutmentwith Standard Abutment Screw4,
45 – 2530 – � D 3.4 conical 30/4
45 – 2531 – � D 3.4 anatomical30/4
45 – 2540 – � D 3.8 conical 30/3
45 – 2541 – � D 3.8 anatomical30/3
45 – 2550 – ● D 4.5 conical 30/3
45 – 2551 – ● D 4.5 anatomical30/3
45 – 2560 – � D 5.5 conical 30/3
45 – 2561 – � D 5.5 anatomical30/3
We recommend using the FRIADENT® CeraBase Tool Set for prepping theceramic sleeve of the FRIADENT® CeraBase Abutment (see page 65).The grinding process does not require irrigation.
Abutments for single tooth restorations and bridges
Prosthetic fabrication at implant level:
Prosthetics/laboratory
Order No. Article
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:19 Uhr52
53
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
Cast-to Abutments
FRIADENT® AuroBase20/8 Abutmentwith Standard Abutment Screw4
(D 3.0 with Abutment Screw4 D 3.0)
45 – 2420 – � D 3.045 – 2430 – � D 3.445 – 2440 – � D 3.845 – 2450 – ● D 4.545 – 2460 – � D 5.5
Telescopic Abutments
FRIADENT® Telescopic Abutmentwith Standard Abutment Screw4
(D 3.0 with Abutment Screw4 D 3.0)
45 – 2620 – � D 3.0 4
45 – 2630 – � D 3.4 4
45 – 2640 – � D 3.8 2
45 – 2650 – ● D 4.5 2
45 – 2660 – � D 5.5 2
The Telescopic Abutment can also be used as a custom abutment for singlecrowns.The Telescopic Abutment can be veneered with titanium ceramics (e.g.,Duceratin, Ducera or Vita Titankeramik, Vita Zahnfabrik) for occlusallyscrew-retained single crowns.
Abutment screws
46 – 4304 � FRIADENT® Standard Abutment Screw4 D 3.0
46 – 4305 � � � � FRIADENT® Screw4 for EstheticBase
Milling Implants
FRIADENT® Milling Implant6
45 – 2621 – � D 3.045 – 2631 – � D 3.445 – 2641 – � D 3.845 – 2651 – ● D 4.545 – 2661 – � D 5.5
Order No. Article
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:20 Uhr53
54
Attachments
FRIADENT® Ball and Socket AttachmentInsert2, Attachment Screw2, Socket9 (gold alloy),with blue silicone ring and white plastic ring
45 – 3131 – � D 3.4/GH 1 4
45 – 3132 – � D 3.4/GH 2 4
45 – 3133 – � D 3.4/GH 3 4
45 – 3141 – � D 3.8/GH 1 2
45 – 3142 – � D 3.8/GH 2 2
45 – 3143 – � D 3.8/GH 3 2
45 – 3145 – � D 3.8/GH 5 2
45 – 3151 – ● D 4.5/GH 1 2
45 – 3152 – ● D 4.5/GH 2 2
45 – 3153 – ● D 4.5/GH 3 2
45 – 3155 – ● D 4.5/GH 5 2
45 – 3161 – � D 5.5/GH 1 2
45 – 3162 – � D 5.5/GH 2 2
45 – 3163 – � D 5.5/GH 3 2
45 – 3165 – � D 5.5/GH 5 2
The gingival collar section of the FRIADENT® Ball and Socket Attachment ispositioned using the FRIADENT® Seating Instrument for Attachment Insert andMP Insert.
The Attachment Screw is seated in the implant using the 1.22 mmFRIADENT® Hex Driver (see page 70).
45 – 3200 � � � � FRIADENT® Attachment Matrix9
45 – 4105 � � � � FRIADENT® Attachment Patrix Analog universal
Prosthetic fabrication at implant level:
Prosthetics/laboratory
Order No. Article
The FRIADENT® Attachment Patrix Analog is used to repair and relineoverdentures. The Analog is snapped into the socket in the denture base afterreline impressions are made. One Patrix Analog is used for all diameters.
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:20 Uhr54
55
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
FRIADENT® MP Abutment2
MP Abutment Insert and MP Insert Screw
46 – 2831 – � D 3.4/GH 146 – 2832 – � D 3.4/GH 246 – 2833 – � D 3.4/GH 346 – 2835 – � D 3.4/GH 5
46 – 2841 – � D 3.8/GH 146 – 2842 – � D 3.8/GH 246 – 2843 – � D 3.8/GH 346 – 2845 – � D 3.8/GH 546 – 2849 – � D 3.8/GH 9
46 – 2851 – ● D 4.5/GH 146 – 2852 – ● D 4.5/GH 246 – 2853 – ● D 4.5/GH 346 – 2855 – ● D 4.5/GH 546 – 2859 – ● D 4.5/GH 9
46 – 2861 – � D 5.5/GH 146 – 2862 – � D 5.5/GH 246 – 2863 – � D 5.5/GH 346 – 2865 – � D 5.5/GH 5
The appropriate MP Abutment Insert is selected according to the gingivalheight. The number of the grooves on the screw head indicates thegingival height of the matching MP Abutment Insert.
GH 1 = 1 ring GH 3 = 3 ringsGH 2 = 2 rings GH 5 = 5 rings
The MP Abutment Inserts are mounted on the implants with the SeatingInstrument for Attachment Insert and MP Insert.
The MP Abutment Screw is tightened with the MP Abutment Screw Driverfor ratchet or handpiece (see page 65).
Prosthetic fabrication at gingival level (MP Abutment):
Transgingival extension,temporary sealing
Order No. Article
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:20 Uhr55
56
FRIADENT® MP Cover Screw2
46 – 1430 – � D 3.446 – 1440 – � D 3.846 – 1450 – ● D 4.546 – 1460 – � D 5.5
Order No. Article
Prosthetic fabrication at gingival level (MP Abutment):
Transgingival extension,temporary sealing
Please note:� D 3.0 components (bronze) can only be used for XiVE®.FRIALIT® implants � D 6.5 (green) are restored with � D 5.5 abutments.
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:20 Uhr56
57
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
Prosthetic fabrication at gingival level (MP Abutment):
Impressions
Order No. Article
FRIADENT® MP Lab Set Transfer ImpressionContent: MP Transfer Impression Coping,MP Analog
46 – 8130 – � D 3.446 – 8140 – � D 3.846 – 8150 – ● D 4.546 – 8160 – � D 5.5
FRIADENT® MP Lab Set PickUp ImpressionContent: MP PickUp Impression Coping,MP PickUp Guide Pin, MP Analog
46 – 8230 – � D 3.446 – 8240 – � D 3.846 – 8250 – ● D 4.546 – 8260 – � D 5.5
FRIADENT® MP Transfer Impression Coping2
46 – 1635 – � D 3.446 – 1645 – � D 3.846 – 1655 – ● D 4.546 – 1665 – � D 5.5
FRIADENT® MP PickUp Impression Coping2
46 – 1630 – � D 3.446 – 1640 – � D 3.846 – 1650 – ● D 4.546 – 1660 – � D 5.5
46 – 1615 � � ● � FRIADENT® MP PickUp Guide Pin4
We recommend securing the MP PickUp Guide Pin with the width 1.22 mmFRIADENT® Hex Driver (see page 70).
FRIADENT® MP Analog5
46 – 4030 – � D 3.446 – 4040 – � D 3.846 – 4050 – ● D 4.546 – 4060 – � D 5.5
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:20 Uhr57
58
Prosthetic fabrication at gingival level (MP Abutment):
Prosthetics/laboratory
FRIADENT® MP Lab Set Bridgewith Castable Waxing SleeveContent: Castable Waxing Sleeve,MP Screw for Waxing Sleeve
46 – 9530 – � D 3.446 – 9540 – � D 3.846 – 9550 – ● D 4.546 – 9560 – � D 5.5
FRIADENT® MP Lab Set Bridgewith Cast-to Waxing SleeveContent: Cast-to Waxing Sleeve,MP Screw for Waxing Sleeve
46 – 9930 – � D 3.446 – 9940 – � D 3.846 – 9950 – ● D 4.546 – 9960 – � D 5.5
Bridges
Order No. Article
Please note:� D 3.0 components (bronze) can only be used for XiVE®.FRIALIT® implants � D 6.5 (green) are restored with � D 5.5 abutments.
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:20 Uhr58
59
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
Waxing Sleeves
FRIADENT® Castable Waxing Sleeve21
45 – 4330 – � D 3.445 – 4340 – � D 3.845 – 4350 – ● D 4.545 – 4360 – � D 5.5
FRIADENT® Cast-to Waxing Sleeve21/8
45 – 4630 – � D 3.445 – 4640 – � D 3.845 – 4650 – ● D 4.545 – 4660 – � D 5.5
Castable Waxing Sleeve: Prior to bridge delivery, smooth the contactsurface between crown and abutment and the screw and screw seat usingthe FRIADENT® Finishers (see page 65).
Cast-to Waxing Sleeve: Smoothing with finishers is not necessary.
46 – 4300 � � � � FRIADENT® MP Screw for Castable Waxing Sleeve4
We recommend using the 1.22 mm FRIADENT® Hex Driver (see page 64)when seating the Screw for the Waxing Sleeve.
Soldering Analogs
45 – 4102 � � � � FRIADENT® Lab Set Soldering Analog for BridgeFRIADENT® Soldering Analog, universal andSoldering Screw for Bridge
45 – 4103 � � � � FRIADENT® Soldering Analog6, universal
45 – 4207 � � � � FRIADENT® Soldering Screw for Bridge4
Order No. Article
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:20 Uhr59
60
Prosthetic fabrication at gingival level (MP Abutment):
Prosthetics/laboratoryBars
FRIADENT® MP Lab Set Gold Bar CopingContent: Gold Bar Coping9, MP Screw for Bar Coping
46 – 9630 – � D 3.446 – 9640 – � D 3.846 – 9650 – ● D 4.546 – 9660 – � D 5.5
FRIADENT® MP Lab Set Titanium Bar CopingContent: Titanium Bar Coping, MP Screw for Bar Coping
46 – 9637 – � D 3.446 – 9647 – � D 3.846 – 9657 – ● D 4.546 – 9667 – � D 5.5
FRIADENT® MP Lab Set Castable Bar CopingContent: Castable Bar Coping, MP Screw for Bar Coping
46 – 9638 – � D 3.446 – 9648 – � D 3.846 – 9658 – ● D 4.546 – 9668 – � D 5.5
Bar Copings
FRIADENT® Gold Bar Coping9
(without screw), for soldering
45 – 4230 – � D 3.445 – 4240 – � D 3.845 – 4250 – ● D 4.545 – 4260 – � D 5.5
FRIADENT® Titanium Bar Coping2
(without screw)
45 – 4231 – � D 3.445 – 4241 – � D 3.845 – 4251 – ● D 4.545 – 4261 – � D 5.5
Order No. Article
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:20 Uhr60
61
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
FRIADENT® Castable Bar Coping21
(without screw)
45 – 4530 – � D 3.445 – 4540 – � D 3.845 – 4550 – ● D 4.545 – 4560 – � D 5.5
46 – 4200 FRIADENT® MP Coping Screw4
We recommend using the 1.22 mm FRIADENT® Hex Driver when seatingMP Coping Screw (see page 64).
Accessories
45 – 4210 FRIADENT® Gold Bar round9
50 mm length
45 – 4215 FRIADENT® Gold Bar Clip9
50 mm length
45 – 4212 FRIADENT® Titanium Bar round2
50 mm length
Soldering Analogs
45 – 4101 � � � � FRIADENT® Lab Set Soldering Analog for BarFRIADENT® Soldering Analog, universal andSoldering Screw for Bar
45 – 4103 � � � � FRIADENT® Soldering Analog6, universal
45 – 4206 � � � � FRIADENT® Soldering Screw for Bar4
Order No. Article
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:20 Uhr61
62
Instrument setsimpression/prosthetics
46 – 7000 FRIADENT® Prosthetic Set Mini
The Prosthetic Set Mini includes all instruments needed forthe prosthetic delivery of implant restorations.
Content:
FRIADENT® RatchetRatchet Hex Driver 0.9 mm/shortRatchet Hex Driver 1.22 mm/short
45 – 8111 FRIALIT® Basic Set Prosthetics
The set includes all clinical instruments necessary forimpression making and prosthetics. The instrumentsare supplied in the FRIALIT® Prosthetic Tray.
Content:
FRIADENT® Ratchet
Handpiece Hex Driver 0.9 mmHandpiece Hex Driver 1.22 mmRatchet Hex Driver 0.9 mm/shortRatchet Hex Driver 1.22 mm/shortRatchet Hex Driver 1.22 mm/longRatchet Slot Screwdriver 2.0 mm/longSeating Instrument for Transfer Coping and MH-6 Abutment/A 0Seating Instrument for Attachment Insert and MP InsertHandpiece Seating Instrument for MP Insert ScrewRatchet Seating Instrument for MP Insert Screw
48 – 0030 FRIALIT® Prosthetic Tray(empty)
Order No. Article
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:20 Uhr62
63
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
26 – 8020 XiVE® Prosthetic Tray
The set includes all clinical instruments necessary forimpression making and prosthetics. The instrumentsare supplied in the XiVE® Prosthetic Tray.
Content:
FRIADENT® Ratchet
Handpiece Hex Driver 0.9 mm/shortHandpiece Hex Driver 0.9 mm/longHandpiece Hex Driver 1.22 mm/shortHandpiece Hex Driver 1.22 mm/longHandle for Handpiece Hex Driver
Ratchet Hex Driver 0.9 mm/shortRatchet Hex Driver 0.9 mm/longRatchet Hex Driver 1.22 mm/shortRatchet Hex Driver 1.22 mm/long
Seating Instrument for Attachment Insert and MP InsertHandpiece Seating Instrument for MP Insert ScrewRatchet Seating Instrument for MP Insert Screw
Insertion Tool EstheticBase
FRIADENT® Select Try-in Abutment D 3.0/A 0FRIADENT® Select Try-in Abutment D 3.4/A 0FRIADENT® Select Try-in Abutment D 3.8/A 0FRIADENT® Select Try-in Abutment D 4.5/A 0FRIADENT® Select Try-in Abutment D 5.5/A 0FRIADENT® Select Try-in Abutment D 3.0/A 15FRIADENT® Select Try-in Abutment D 3.4/A 15FRIADENT® Select Try-in Abutment D 3.8/A 15
26 – 8025 XiVE® Prosthetic Tray(empty)
Order No. Article
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:20 Uhr63
64
Instruments for impression/prosthetics/laboratory
45 – 5709 FRIADENT® Ratchet6, without inserts
FRIADENT® Ratchet Hex Driver6
with torque limit45 – 5732 – width 0.9 mm/14 Ncm/short45 – 5733 – width 0.9 mm/14 Ncm/long45 – 5734 – width 1.22 mm/24 Ncm/short45 – 5736 – width 1.22 mm/24 Ncm/long
FRIADENT® Ratchet Slot Screwdriver6
with torque limit45 – 5714 – blade width 2.0 mm/14 Ncm/short45 – 5722 – blade width 2.0 mm/14 Ncm/long
FRIADENT® Handpiece Hex Driver6
46 – 5710 – width 0.9 mm/short46 – 5720 – width 0.9 mm/long46 – 5711 – width 1.22 mm/short46 – 5721 – width 1.22 mm/long
FRIADENT® Handpiece Slot Screwdriver6
46 – 5712 – blade width 2.0 mm/short46 – 5722 – blade width 2.0 mm/long
46 – 5750 FRIADENT® Handle for Handpiece Hex Driver6
This handle fits all handpiece drivers.
FRIADENT® Hex Driver6
without torque limit45 – 5650 – width 0.9 mm
The 0.9 mm FRIADENT® Hex Driver without torque limit is recommended forregions with limited access.
Order No. Article
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:20 Uhr64
65
FRIA
DEN
T® P
rosth
etic
sfo
r FR
IALI
T® &
XiV
E® S
45 – 5605 FRIADENT® Seating Instrument for Transfer Coping andMH-6 Abutment /A 0
45 – 5702 FRIADENT® Finisher6/10 for Horizontal Screw Seat
45 – 5600 FRIADENT® Hermetics Basic Set(Seating Instrument, 20 Hermetics Sealing Rings)
45 – 5601 FRIADENT® Hermetics Seating Instrument2
45 – 5750 FRIADENT® CeraBase Tool SetContents: Medium Diamond Drill, Fine Diamond Drill,Rubber Polishing Wheel
45 – 5753 FRIADENT® CeraBase Medium Diamond Drill
45 – 5755 FRIADENT® CeraBase Fine Diamond Drill
45 – 5758 FRIADENT® CeraBase Rubber Polishing Wheels (5 pieces)
45 – 5617 FRIADENT® Seating Instrument2
for Attachment Insert and MP Insert
46 – 5610 FRIADENT® Ratchet Seating Instrument6
for MP Insert Screw
46 – 5615 FRIADENT® Handpiece Seating Instrumentfor MP Insert Screw
45 – 5621 FRIADENT® Activator6 for Ball and Socket Attachment
45 – 5622 FRIADENT® Deactivator6 for Ball and Socket Attachment
45 – 5623 FRIADENT® Bar Clip Activator6
FRIADENT® Finisher6/10 for Abutment Seatfor screw-retained superstructures
45 – 5705 – � � � D 3.4 – D 4.545 – 5707 – � D 5.5
45 – 5700 FRIADENT® Finisher6/10 for Screw Head Seatfor screw-retained superstructures
Order No. Article
ArtKat_FX_FRIADENT_3E_rev007 21.06.2007, 11:21 Uhr65
66
XiVE® TGXiVE® TG plus –the transgingival alternative
If function is the first priority, then the single-componenttransgingival XiVE® TG plus implant is recommended.As a leader in innovation, DENTSPLY Friadent accepts theobligation to apply new scientific insights to the develop-ment of existing and new implant systems.XiVE® TG plus is the result of the scientific and clinicalexperience accumulated with the New Ledermann Screwand FRIALOC® systems.With the implant-abutment connection and the machinedimplant collar extending through the soft tissue, thetransgingival implant looks like a XiVE® S plusimplant with an integrated MP abutment.
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:19 Uhr66
67
Indications
Cases:■ where a transgingival implant design is indicated■ when temporary and definitive components are needed
for simple and fast prosthetic restoration■ requiring increased primary stability for early or
immediate implant function■ with atrophied ridges where augmentation is not
desired or indicated, multiple implant restorations inposterior regions
■ where a cylindrical implant design is advantageous –particularly in the lateral region
■ where the local bone must be used to the maximumpossible extent: implant lengths available range from8 to 18 mm
Macro-design
The cylinder-shaped design for internal condensation ofthe peri-implant bone prevents trauma and increasesprimary stability of implants, even in spongy bone.
Micro-design
The innovative thread design of XiVE® screw implantscombined with the bone-class-specific preparation of theimplant site provides torque stabilization in all bonequalities.
Nano-design
Growth-activating FRIADENT® plus surface. TransgingivalScrew implant with trimodal surface morphologyproviding an ideal environment for functional adaptationof epithelium, connective tissue and bone.
Implant diameterX
iVE®
TG
D 3.4 D 3.8 D 4.5
XiVE® TG � � �
The XiVE® TG product range is a further development ofthe FRIALOC® implant system. All XiVE® TG componentsand instruments (except the drills) are fully compatiblewith FRIALOC®.Previously placed FRIALOC® implants can still be restoredwith components of the XiVE® TG prosthetic line.
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:19 Uhr67
68
Implant placement
2. Place the XiVE® TGRatchet or HandpieceImplant Driver onto theAdapter Screw.
3. Remove the implantwithout touching the innervial.
4. Remove the ImplantHolder.
5. Place XiVE® TG plusScrew Implant. Pleasefollow the instructions foruse.
XiVE® TG sterile packaging for implants
All FRIADENT® Screw Implants are packed in gammasterilized, transparent double vials. The color-coded capis sealed with an adhesive label.
■ Transparent outer vial –to see the content
■ Color-coded cap displaying the implant length –for clear identification
■ Sterile inner vial with implant retaining stopper –for fast and safe no-touch placement of implants
■ Peel-off labels –for a reliable documentation
No-touch insertion XiVE® TG plusTransgingival Screw Implant
1. Remove the outer vial cap (non-sterile) and drop thesterile inner vial onto the surgical tray.
The undamaged label clearly indicates that thesterile package has not been opened and thus
product sterility.
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:19 Uhr68
69
For the pre-surgical planning of XiVE®TG plus, the same components asfor XiVE®S Screw Implants are used (see pages 22/23).
Implants (sterile)
XiVE® TG plusTransgingival Screw ImplantScrew Implant3, Adapter Screw
25 – 1431 – � D 3.4/L 9.525 – 1432 – � D 3.4/L 1125 – 1433 – � D 3.4/L 1325 – 1435 – � D 3.4/L 1525 – 1438 – � D 3.4/L 18
25 – 1440 – � D 3.8/L 825 – 1441 – � D 3.8/L 9.525 – 1442 – � D 3.8/L 1125 – 1443 – � D 3.8/L 1325 – 1445 – � D 3.8/L 1525 – 1448 – � D 3.8/L 18
25 – 1450 – � D 4.5/L 825 – 1451 – � D 4.5/L 9.525 – 1452 – � D 4.5/L 1125 – 1453 – � D 4.5/L 1325 – 1455 – � D 4.5/L 1525 – 1458 – � D 4.5/L 18
An Adapter Screw is pre-mounted on XiVE® TG plus Screw Implantsto secure the Implant Driver.
Use the XiVE® TG Ratchet or Handpiece Implant Driver (see page 76)to thread in the XiVE® TG Implants.After rotating in the implant, the Adapter Screw is removed with the0.9 mm FRIADENT® Hex Driver.
25 – 9200 XiVE® TG Clinical Set Cover Screw(Four Cover Screws)
25 – 1400 � � � XiVE® TG Cover Screw for Implants2
The Cover Screws are placed with the 0.9 mm FRIADENT® Hex Driver.
Order No. Article
XiV
E® T
G
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:19 Uhr69
70
Instruments
XiVE® Instrument Sets Surgery
The XiVE® Instrument Sets Surgery contain the instrumentsrequired for implant placement (see page 30).The kits are supplied in the XiVE® Surgical Tray.
26 – 8000 XiVE® ExpertSet Surgery5/6/26
26 – 8005 XiVE® StandardSet Surgery5/6/26
Drills and drill sequence for transgingival XiVE® TG Implants are identicalto those of subgingival XiVE® S Implants (see page 28/29).XiVE® BoneCondenser may also be used (see page 35).
Other Instruments
25 – 5206 XiVE® TG Radiographic Template (transgingival)
45 – 5709 FRIADENT® Ratchet6, without inserts
25 – 5600 XiVE® TG Ratchet Implant Driver6
25 – 5601 XiVE® TG Handpiece Implant Driver6
FRIADENT Ratchet Hex Driver6
with torque limit45 – 5732 – width 0.9 mm/14 Ncm/short45 – 5733 – width 0.9 mm/14 Ncm/long45 – 5734 – width 1.22 mm/24 Ncm/short45 – 5736 – width 1.22 mm/24 Ncm/long
FRIADENT Handpiece Hex Driver6
46 – 5710 – width 0.9 mm/short46 – 5720 – width 0.9 mm/long46 – 5711 – width 1.22 mm/short46 – 5721 – width 1.22 mm/long
Order No. Article
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:20 Uhr70
71
Single Crowns Bridges Overdentures
XiVE® TG AuroBase
XiVE® TGGold, Titanium or
Castable Bar Coping
Impressions
XiVE® TG Abutmentstraight orangled 15°
XiVE® TG WaxingSleeves
XiVE® TGTransfer Impression
Coping
XiVE® TGPickUp Impression
Coping
Components are selected based on the prosthetic concept.
XiVE® TG Prosthetics
The XiVE® TG product range is a further development of the FRIALOC® implant system. All XiVE®
TG components and instruments (except the drills) are fully compatible with FRIALOC®.Previously placed FRIALOC® implants can still be restored with components of the XiVE® TGprosthetic line.
XiV
E® T
G
XiVE® TG Abutmentstraight orangled 15°
XiVE® TGAttachment
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:20 Uhr71
72
Impressions
25 – 9100 � � � XiVE® TG Clinical Set Transfer ImpressionD 3.4 – D 4.5 (Four Transfer Impression Copings )
25 – 9105 � � � XiVE® TG Clinical Set Transfer Impression (short)D 3.4 – D 4.5 (Four Short Transfer Impression Copings)
25 – 9112 � � � XiVE® TG Clinical Set PickUp ImpressionD 3.4 – D 4.5 (Four PickUp Impression Copings withfour TG PickUp Guide Pins)
25 – 1600 � � � XiVE® TG Transfer Impression Coping2
D 3.4 – D 4.5
25 – 1605 � � � XiVE® TG Transfer Impression Coping (short)2
D 3.4 – D 4.5
The short Impression Copings are used for making the impression with anexisting prosthesis.
25 – 1805 � � � XiVE® TG PickUp Impression Coping2
D 3.4 – D 4.5with PickUp Guide Pin
25 – 1701 � � � XiVE® TG PickUp Guide Pin4
If, in cases of implant divergencies, a transfer of the square head is notrequired, please use the FRIADENT® MP Transfer Impression Coping D 3.8(Order no. 46 –1640, see page 57). This impression coping is compatiblewith all diameters of XiVE® TG.
Order No. Article
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:20 Uhr72
73
IMZ
-T
win
Plu
s
Prosthetics/laboratory
25 – 9900 � � � XiVE® TG Lab Set Bridge(Castable Waxing Sleeve) D 3.4 – D 4.5(Four TG Castable Waxing Sleeves, four TG Abutment Screws)
25 – 9905 � � � XiVE® TG Lab Set Bridge(Cast-to Waxing Sleeve) D 3.4 – D 4.5(Four TG Cast-to Waxing Sleeves, four TG Abutment Screws)
25 – 4245 � � � XiVE® TG Castable Waxing Sleeve21
D 3.4 – D 4.5 with TG Abutment Screw
25 – 4246 � � � XiVE® TG Cast-to Waxing Sleeve21/8
D 3.4 – D 4.5 with TG Abutment Screw
25 – 4300 � � � XiVE® TG Abutment Screw4
D 3.4 – D 4.5
Soldering Analogs
25 – 9305 � � � XiVE® TG Lab Set Implant-Soldering Analog (Bridge)D 3.4 – D 4.5(Four TG Implant-Soldering Analogs, four TG AbutmentScrews)
25 – 4105 � � � XiVE® TG Lab Set Soldering Analog BridgeD 3.4 – D 4.5TG Implant-Soldering Analog with TG Abutment Screw
The TG Soldering Analog is used for securing the framework in thesoldering base.
Bridges
25 – 9405 � � � XiVE® TG Implant-Soldering Analog Multipack D 3.4 – D 4.5 (Four TG Implant-Soldering Analogs)
25 – 4010 � � � XiVE® TG Implant-Soldering Analog6
D 3.4 – D 4.5
XiV
E® T
G
Order No. Article
Order No. Article
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:20 Uhr73
74
Prosthetics/laboratory
25 – 4500 � � � XiVE® TG Abutment straight2
D 3.4 – D 4.5 (straight)with TG Abutment Screw
25 – 4510 � � � XiVE® TG Abutment angled 15°2
D 3.4 – D 4.5 (angled 15°)with TG Abutment Screw
All straight and angled TG Abutments are provided with a horizontal thread(M 1.4). An additional horizontal or transverse screw set is necessary forhorizontally screw-retained crowns (see page 51).
We recommend the use of special titanium drills (Gebr. Brasseler, Lemgo orJota Düsseldorf) for preparing the abutments.
25 – 4520 � � � XiVE® TG AuroBase20/8
D 3.4 – D 4.5with TG Abutment Screw
25 – 4300 � � � XiVE® TG Abutment Screw4
25 – 4401 � � � XiVE® TG Attachment2/4
D 3,4 – D 4,5
Bridges and single crowns
Order No. Article
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:20 Uhr74
75
IMZ
-T
win
Plu
s
25 – 9600 � � � XiVE® TG Lab Set Gold Bar Coping9 D 3.4 – D 4.5(Four TG Gold Copings, four TG Coping Screws)
25 – 9700 � � � XiVE® TG Lab Set Titanium Bar Coping D 3.4 – D 4.5(Four TG Titanium Copings, four TG Coping Screws)
25 – 9800 � � � XiVE® TG Lab Set Castable Coping D 3.4 – D 4.5(Four TG Castable Copings, four TG Coping Screws)
25 – 4240 � � � XiVE® TG Gold Bar Coping9
D 3.4 – D 4.5with TG Coping Screw
25 – 4241 � � � XiVE® TG Titanium Bar Coping2
D 3.4 – D 4.5with TG Coping Screw
25 – 4242 � � � XiVE® TG Castable Bar Coping21
D 3.4 – D 4.5with TG Coping Screw
25 – 4200 � � � XiVE® TG Coping Screw4
Accessories
45 – 4210 FRIADENT Gold Bar round9
50 mm length
45 – 4212 FRIADENT Titanium Bar round2
50 mm length
45 – 4215 FRIADENT Gold Bar Clip9
50 mm length
Soldering Analogs
25 – 9306 � � � XiVE® TG Lab Set Implant-Soldering Analog (Bar)D 3.4 – D 4.5(Four TG Implant-Soldering Analogs, four TG Coping Screws)
25 – 4106 � � � XiVE® TG Lab Set Soldering Analog BarD 3.4 – D 4.5TG Implant-Soldering Analog with TG Coping Screw
Overdentures
XiV
E® T
G
Order No. Article
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:20 Uhr75
76
Instruments for impression/prosthetics/laboratory
45 – 5709 FRIADENT® Ratchet6, without inserts
FRIADENT Ratchet Hex Driver6
with torque limit45 – 5732 – width 0.9 mm/14 Ncm/short45 – 5733 – width 0.9 mm/14 Ncm/long45 – 5734 – width 1.22 mm/24 Ncm/short45 – 5736 – width 1.22 mm/24 Ncm/long
FRIADENT Handpiece Hex Driver6
46 – 5710 – width 0.9 mm/short46 – 5720 – width 0.9 mm/long46 – 5711 – width 1.22 mm/short46 – 5721 – width 1.22 mm/long
46 – 5750 FRIADENT® Handle for Handpiece Hex Driver6
This handle fits all handpiece drivers.
25 – 5705 XiVE TG Finisher
Order No. Article
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:20 Uhr76
77
XiV
E® T
G
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:20 Uhr77
78
Presentation material
45 – 9992 Large scale model FRIALIT® Synchro 5 :1(with crown)
45 – 9981 FRIADENT® Acrylic model maxilla without prosthetics(ANKYLOS®, FRIALIT®, XiVE®)
45 – 9982 FRIADENT® Acrylic model maxilla with prosthetics(ANKYLOS®, FRIALIT®, XiVE®)
45 – 9985 XiVE® Acrylic model mandible without prosthetics(bar construction)
45 – 9986 XiVE® Acrylic model mandible with prosthetics(bar construction)
26 – 9110 XiVE® Large Scale Model Set 5:1
CD-ROMs for Presentation
Each CD-ROM contains Powerpoint Presentations and high-resolution picturefiles for the exposing of slides
66 – 1035 CD-ROM FRIALIT® Basics Surgery and Prosthetics
66 – 4037 CD-ROM FRIALIT® Synchro, FRIALIT® BoneProfiler
66 – 4038 CD-ROM FRIALIT® MP-Abutment
66 – 4039 CD-ROM FRIALIT® Select
66 – 7010 CD-ROM XiVE®, PowerPoint presentation and slides
66 – 4036 CD-ROM FRIALIT® Video Sequences in PowerPoint
66 – 4501 CD-ROM, Picture CD FRIALIT®/XiVE®
66 – 1036 CD-ROM, Picture CD DENTSPLY Friadent
66 – 1037 CD-ROM, Picture CD CERCON® plus
66 – 1038 CD-ROM, Picture CD Internet, all Systems
66 – 1067 CD-ROM CERCON®, PowerPoint presentation
66 – 1066 CD-ROM FRIADENT® plus, PowerPoint presentation
Videos
66 – 4046 FRIALIT® System Video (English, PAL)
66 – 4047 FRIALIT® System Video (English, NTSC)
5 – 701012 Implant Passport XiVE®
Order No. Article
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:20 Uhr78
79 Pres
enta
tion
mat
eria
l
Materials
Type Index Composition
Titanium 1 Ti grade 1Titanium 2 Ti grade 2Titanium 3 Ti grade 4Titanium 4 Ti6AL4V
Aluminium 5 AlMg3
Stainless steel 6 DIN 1.4305Brass 7 CuZnCast-to alloy* 8 Au: 60%, Pt: 19%, Pd: 20%, Ir: 1%Gold alloy ** 9 Au: 68.6%, Pt: 2.4%, Pd: 4%, Ag: 11.8%,
Cu: 10.6%, Ir: 0.1%, Zn: 2.5%Hard metal 10 K 40
Metals
* TEC 11.9 x 10-6 K-1, pre-heating temperature < 850°C, cast temperature < 1450°C** melting interval from 880 – 940°C
Plastics
Type Index
Polyoxymethylene 20Polymethylmethacrylate 21Polystyrene 22Polytetrafluourethylene 23Polyetheretherketone 24Polyetherimide 25Silicone 26Polycarbonate 27Polypropylene 28
Typ Index Composition
Aluminium oxide 30 Al2O3
Hydroxyapatite 31 Ca5(PO4)3OH
Zirconium oxide 32 ZrO2
Ceramics
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:20 Uhr79
80
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:20 Uhr80
81
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:20 Uhr81
82
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:20 Uhr82
83
FRIADENT Class l Medical Devices
In terms of the Directive 93/42/EEC Class l Medical Devices are:– Non-active hand-held surgical and prosthetic instruments for implant placement and
augmentation– Components for impression technique, which do not remain in the patient’s mouth– Non-active components for the planning stage
FRIADENT Class lla, llb and lll Medical Devices
In terms of the Directive 93/42/EEC Class lla, llb and lll Medical Devices are:– Dental Implants, membranes, membrane nails as well as bone reconstruction materials– Active surgical and prosthetic instruments for implant placement and augmentation– Components for impression technique and prosthetic overdenture, which remain in the
patient’s mouth
Manufacturer:FRIADENT GmbH · P. O. Box 71 01 11 · 68221 Mannheim/GermanyPhone: + 49 621 4302-1288 · Fax: + 49 621 47 13 06e-Mail: [email protected] · Internet: http://www.friadent.de
0123
ArtKat_FX_XiVETG_4E_rev007 21.06.2007, 13:20 Uhr83
Order No. 6-452001/009
Manufacturer:FRIADENT GmbH · P. O. Box 71 01 11 · 68221 Mannheim/GermanyPhone: + 49 621 4302-1288 · Fax: + 49 621 47 13 06e-Mail: [email protected] · Internet: http://www.friadent.de
0607
09/S
B
ArtKat_FX_Tit_E_rev007 21.06.2007, 10:56 Uhr2