17
88 CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES EXTERNAL UNLOADER CONVERSION KIT Kit is used to bypass the standard 5 line (5F40 thru 5H126) cylinder unloading system that responds to changes in suction pressure. A field supplied controller is used in conjunction with this kit to control sole- noid valves that activate/deactivate cylinder unloaders. External capacity control results in more precise compressor capacity matching to the load. COMPRESSOR MODEL P/N COMPRESSOR MODEL P/N 5F40 5F40-4FI-A 5H60,66,80,86 5H60-4FI-A 5F60 5F60-4FI-A 5H120,126 5H120-4FI-A 5H40,46 5H40-4FI-A 5F Kits contain hand hole cover. 5H Kits contain blankoff plates. 120 Volt solenoid coils. SERVICE VALVES (+)May be either “A” (Remanufactured) or “S” (New Manufactured). ‡These Models require a suction and a discharge manifold in order to mount the service valve. *Requires a suction valve adapter (P/N: 5H660-006). Requires a discharge valve adapter (P/N: 5H660-005). RELIEF VALVE KIT Compressor Models 5H 120 & 126 Require the addition of a relief valve and associated piping. COMPRESSOR MODEL SUCTION SERVICE VALVE P/N DISCHARGE SERVICE VALVE P/N 5F COMPRESSORS 5F20-S674 06DA660063 06DA660062 5F20-A684 06DA660063 06DA660062 5F20-S684 06DA660063 06DA660062 5F30-Al89 06EA660090 06DA660065 5F30-S644 06EA660090 06DA660065 5F30-A219 06EA660090 06DA660065 5F30-S664 06EA660090 06DA660065 5F40-A219 06EA660090 06DA660065 5F40-S219 06EA660090 06DA660065 5F60-A219 5F660-002 5F660-001 5F60-S219 5F660-002 5F660-001 5H COMPRESSORS 5H40-(+)219 5H660-008 5F660-002 5H46-(+)219 5H660-008 5F660-002 5H60-(+)219‡ 06LA660010 06LA660010 5H66-(+)219‡ 06LA660010 06LA660010 5H80-(+)219 06LA660010* 06LA660010 5H86-(+)219 06LA660010* 06LA660010 5H120-(+)219‡ 06LA660011 06LA660011 5H126-(+)219‡ 06LA660011 06LA660011 P/N: 5H120-337 P77 Relief Valve Kit P78 MANIFOLDS The Models listed require the addition of a suction and discharge manifold in order to mount the service valve. MUFFLERS COMPRESSOR MODEL SUCTION MANIFOLD P/N DISCHARGE MANIFOLD P/N 5F60-A219 5F60-1094 NONE 5H60,66 5H660-007 5H660-007 5H120,126 5H660-001 5H660-003 COMPRESSOR MODEL LENGTH (in.) CONN. SIZE (in.) MUFFLER P/N 5F20 11-1/4 1-1/8 O.D.F 06DA605614 5F30,40,60 13-3/4 1-3/8 O.D.F 05HY500853 5H40,46,60,66 22-5/8 2-5/8 O.D.F 05HY500863 5H80,86,120,126 22-5/8 3-1/8 O.D.F 05HY501013 MANIFOLDS P78 P75 P81

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES · mount the service valve. *Requires a suction valve adapter (P/N: 5H660-006). Requires a discharge valve adapter (P/N: 5H660-005). RELIEF

  • Upload
    others

  • View
    70

  • Download
    1

Embed Size (px)

Citation preview

88

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

EXTERNAL UNLOADER CONVERSION KITKit is used to bypass the standard 5 line (5F40 thru 5H126) cylinder unloading system that responds to changes in suction pressure.

A field supplied controller is used in conjunction with this kit to control sole-noid valves that activate/deactivate cylinder unloaders.

External capacity control results in more precise compressor capacity matching to the load.

COMPRESSORMODEL

P/NCOMPRESSOR

MODELP/N

5F40 5F40-4FI-A 5H60,66,80,86 5H60-4FI-A5F60 5F60-4FI-A 5H120,126 5H120-4FI-A

5H40,46 5H40-4FI-A 5F Kits contain hand hole cover.5H Kits contain blankoff plates.120 Volt solenoid coils.

SERVICE VALVES

(+)May be either “A” (Remanufactured) or “S” (New Manufactured).‡These Models require a suction and a discharge manifold in order to mount the service valve.

*Requires a suction valve adapter (P/N: 5H660-006). Requires a discharge valve adapter (P/N: 5H660-005).

RELIEF VALVE KIT

Compressor Models 5H 120 & 126 Require the addition of a relief valve and associated piping.

COMPRESSORMODEL

SUCTIONSERVICE VALVE

P/N

DISCHARGESERVICE VALVE

P/N

5F COMPRESSORS5F20-S674 06DA660063 06DA6600625F20-A684 06DA660063 06DA6600625F20-S684 06DA660063 06DA6600625F30-Al89 06EA660090 06DA6600655F30-S644 06EA660090 06DA6600655F30-A219 06EA660090 06DA6600655F30-S664 06EA660090 06DA6600655F40-A219 06EA660090 06DA6600655F40-S219 06EA660090 06DA6600655F60-A219 5F660-002 5F660-0015F60-S219 5F660-002 5F660-001

5H COMPRESSORS5H40-(+)219 5H660-008 5F660-0025H46-(+)219 5H660-008 5F660-0025H60-(+)219‡ 06LA660010 06LA6600105H66-(+)219‡ 06LA660010 06LA6600105H80-(+)219 06LA660010* 06LA6600105H86-(+)219 06LA660010* 06LA660010

5H120-(+)219‡ 06LA660011 06LA6600115H126-(+)219‡ 06LA660011 06LA660011

P/N: 5H120-337

P77

Relief Valve Kit

P78

MANIFOLDS

The Models listed require the addition of a suction and discharge manifold in order to mount the service valve.

MUFFLERS

COMPRESSORMODEL

SUCTIONMANIFOLD

P/N

DISCHARGEMANIFOLD

P/N5F60-A219 5F60-1094 NONE

5H60,66 5H660-007 5H660-0075H120,126 5H660-001 5H660-003

COMPRESSORMODEL

LENGTH(in.)

CONN.SIZE (in.)

MUFFLERP/N

5F20 11-1/4 1-1/8 O.D.F 06DA6056145F30,40,60 13-3/4 1-3/8 O.D.F 05HY500853

5H40,46,60,66 22-5/8 2-5/8 O.D.F 05HY5008635H80,86,120,126 22-5/8 3-1/8 O.D.F 05HY501013

MANIFOLDS

P78

P75

P81

89

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

CRANKCASE HEATER RELAYS

The Crankcase Heater Relay is used to energize the Heater when the compressor is not in operation. The Crankcase Heater Relay is not required when using 32 Series control panels.

COIL VOLTS P/N120 HN61AJ101240 HN61AJ108

*These Models Require Two Heaters.

COMPRESSOR MODEL USED ON

WATTS VOLTSLEAD

LENGTH (in.)

SHEATH LENGTH

(in.)P/N

5F20,3,040,60 100 120 48 7 HT31AZ1205F20,30,40,60 100 240 48 7 H731AZ240

5H40,46,60,66,80*, 86*,120*,126*

200 120 63 7 HT31AZ121

5H40,46,60,66,80*,16*,120*,126*

200 240 63 7 HT31AZ241

P82

CRANKCASE HEATERS

P85

5F/5H LUBE OIL CONTROL

TIME DELAY CONNECTIONSPRESSURE

DIFFERENTIAL VOLTS RESETP/N

KITCONTROL

ONLYCUT-IN CUT-OUT

45 Seconds36″ Lg. Cap w/1/

4″ Fl. Nuts15-20 psi 11-15 psi 115/230 Manual 5F20-212 P529-4120

OIL COOLER PACKAGE

OIL FILTER PACKAGE

COMPRESSOR USED ON

P/N

All 5F 5F20-B1035H40,46,60,66,80,86 5H40-B283

5H120,126 5H120-B283

Package Includes: (1) partial flow oil filter with fittings, (2) angle valves, tubing and (2) oil pressure gauges. All 5H120,126 are supplied standard with a full flow oil filter.

Use on: 5H40, 46, 60, 66, 80, 86 compressor models

P/N: 5H40-A274

OIL FILTER ONLY . . . . . . . . . . . . . . . . . . . . . . . . . P/N: 05HG660020

P83

P84

P86

90

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

CAPACITY CONTROL VALVE PACKAGE

For use on 5F20,30 compressors.

FELT FILTER KIT

Felt Filters are installed in the compressor’s suction strainer as a temporary clean up medium.

NOTE: Filter Kit is included with service compressors.

COMPRESSOR MODELREFRIGERANT

USAGEP/N

5F20,30 R-12 5F20-7525F20,30 R-22,R-502 5F20-A752

COMPRESSOR MODEL

NO. FILTERS REQUIRED PER COMP.

P/N

KIT FILTER ONLY

5F40,46 1 5F40-A352 5F40-37925F60,66 2 5F60-A352 5F60-37925H40,46 1 5H40-A382 5H40-40325H60,66 2 5H60-A382 5H60-40325H80,86 1 5H80-A382 5H80-4032

5H120,126 2 5H120-A382 5H120-4552

P87

P88

WATER-COOLED HEAD PACKAGE

VIBRATION ISOLATORSVIBRATION ISOLATORS limit the transfer of vibration. They are attached underneath the surface to which the com-pressor is mounted. Four isolators are supplied in each package. One for each corner of the unit. Associated hardware is also included. Select proper size isolator by dividing total unit weight by 4.

P/N 5F20-623 5F30-623 5F60-633 5F60-663 5H40-653 5H60-673 5H80-673 5H120-467 5H120-527ISOLATOR LOADING

LBS/ISOLATOR90 to 150 150 to 210 210 to 290 290 to 390 350 to 450 450 to 650 650 to 950 950 to 1250 1250 to 1550

5H40,46 5H40-507

5H60,66 5H60-507

5H80,86 5H80-507

5H120,126 5H120-507

5F COMPRESSORS

COMPRESSOR MODEL P/N

Water Cooled Heads are required for compressors used on low temp R-22 applications. See Compressor Ratings on pages 4 & 5 for application ranges. The water cooled head packages listed contain the necessary heads, covers, gaskets, and fittings to convert standard 5F/H compressors to water cooled heads.

DOWEL PIN

5F COMPRESSORS

COMPRESSOR MODEL P/N

5F20 5F20-172

5F30 5F30-172

5F40 5F40-172

5F60 5F60-172

Tapered dowel pin (no. 6 x 2-3/4″ long) is used to maintain alignment and to ensure exact compressor/motor repositioning after service. Two Pins are required for both motor and compressor. (Pins for motor are included in motor fastening package.)

P/N: AX35AA238

DRILL & REAMER KITDrill and reamer kit includes a 9/32 in. drill bit and a no. 6 taper reamer to facilitate installation of the no. 6 tapered dowel pin.

P/N: 5H40680004

P90

P91

P92

P89

91

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

FLEXIBLE STEEL COUPLINGSFOR DIRECT DRIVE UNITS

*When 5H126-623 coupling is used with a 404T or 405T frame motor, field boring is required. Enlarge motor bore to 2.875/2.8755 in. diameter. Increase Keyway size to 3/4 x 3/8 in.

COMPRESSOR MODEL

MOTORH. P.

MOTOR FRAMESIZE

MOTOR SHAFT

DIA. (in.)

MAXIMUM COUPLING

H.P. RATING

WT. (lbs) P/N

5F20,307-1/2,10 213T, 215T 1.375 11.5 10 5F20-847

15 254T 1.625 17.5 10 5F30-847

5F40,60

7-1/2,10 213T, 215T 1.375 17.5 15 5F40-60315 254T 1.625 17.5 15 5F40-62320 256T 1.625 30.0 21 5F60-623

25,30 284T, 286T 1.875 34.5 21 5F60-613

5H40,46

20 256T 1.625 34.5 21 5H40-61325,30 284T, 286T 1.875 65 24 5H60-613

40,50,60 324TS, 326TS, 364TS 1.875 65 24 5H60-61340,50 324T, 326T 2.125 65 24 5H60-623

60 364T 2.375 86 30 5H80-613

5H60,66

30 286T 1.875 65 24 5H60-61340,50,60 324TS, 326TS, 364TS 1.875 65 24 5H60-613

40,50 324T, 326T 2.125 65 24 5H60-62360,75 364T, 365T 2.375 86 30 5H80-613

75 365TS 1.875 86 30 5H80-663100 404TS 2.125 150 35 5H120-623

5H80,86

40,50,60 324TS, 326TS, 364TS 1.875 65 24 5H60-61340,50 324T, 326T 2.125 65 24 5H60-62360,75 364T, 365T 2.375 86 30 5H80-613

75 365TS 1.875 86 30 5H80-663100 404TS, 405TS 2.125 150 35 5H120-623

5H120,126

60 364TS 1.875 65 24 5H60-61360,75 364T, 365T 2.375 86 30 5H80-613

75 365TS 1.875 86 30 5H80-663100,125 404TS, 405TS 2.125 150 35 5H120-623100,125 404T, 405T 2.875 200 40 5H126-623 *150,200 444TS, 445TS 2.375 200 40 5H126-623 *

MOTOR FASTENING KITS FORDIRECT DRIVE APPLICATIONS

Motor Fastening Kit includes steel blocks and shims to align motor shaft to compressor shaft, hardware to attach motor to base and tapered dowel pins to pin motor to base and lock in alignment.Not enough memory to convert the items on the clipboard.

P99

NOTE: Motor Fastening kit approximate shipping weight is 42 lbs.

COMPRESSOR MODEL

COMPRESSOR SHAFT HT. (in.)

MOTOR HP

MOTOR FRAME SIZE

MOTOR SHAFT HT. (in.)

P/N

5F20,30 6-1/47-1/2,10 213T, 215T 5-1/4

5F40-401/5F40-801

15 254T 6-1/4 5F40-801

5F40,60 87-1/2,10 213T, 215T 5-1/4 5F40-801

15,20 254T, 256T 6-1/4 5F40-40125,30 284T, 286T 7 5F40-401

5H40,46 9

20 256T 6-1/4 5F40-80125,30 284T, 286T 7 5H40-40140,50 324, 326 T/Ts 8 5F40-40160,75 364, 365 T/TS 9 5F60-401

5H60,66 9

30 286T 7 5H40-40140,50 324, 326 T/TS 8 5F40-40160,75 364, 365 T/TS 9 5F60-401100 404 T/TS 10 5F60-401

5H80,86 940,50 324, 326 T/TS 8 5F40-40160,75 364, 365 T/TS 9 5F60-401

100,125 404, 405 T/TS 10 5F60-401

5H120,126 1160,75 364, 365 T/TS 9 5H40-401

100,125 404, 405 T/TS 10 5F40-401150,200 444, 445 TS 11 5F60-401

NOTE: A Dial Indicator must be used to properly align the compressor and motor shafts for reliable operation.

P98

92

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

MOTOR FASTENING KITFOR BELT DRIVE APPLICATIONS

Motor Fastening Kit attaches motor to base.Kit includes: bolts, nuts and washers.

COMPRESSORMODEL

MOTOR SIZE MOTOR FRAME SIZE P/N

5F20,30 5, 7-1/2, 10 184T, 213T, 215T 5F20-8215F30 15 254T 5F30-821

5F40,607-1/2, 10 213T, 215T

5F20-82115, 20, 25 254T, 256T, 284T

5H4020, 25, 30 256T, 284T, 286T

5F30-82140,50 324T, 326T

5H60 40,50 324T, 326T 5F30-821

5H6040,50 324T, 326T

5H40-71160,75 364T, 365T

Compressor Mounting Block is used when a 5H66,80,86 is matched to a 100 Hp motor, or when a 5H86 is matched to a 125 Hp motor. The block raises compressor to allow alignment between compressor and motor shaft. Two blocks are required per compressor.

5H80, 12040,50,60,75 324T, 326T, 364T, 365T

5H40-711100,125,150 404T, 405T, 444T

P/N: 5H40-1422

COMPRESSORMODEL

MOTOR SIZE MOTOR FRAME SIZE P/N

P100

93

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

CONTROL PANELSControl panels are designed for indoor use to control compressor and condensing units from 5 thru 150 Hp, in 208 to 575 volts, across-the-line starting applications. All units operate on 120 volt control circuit.

Control panel easily mounts on one end of the unit base. Sim-ple conversion to part-winding starting on 2 contactor models by adding time delay P/N HN67ZA001. Single contactor pan-els require the addition of another contactor of the same size and time delay P/N HN67ZA001.

* Single overload panels: overload dial is set at a value equal to NEC motor full load current rating and will trip at 125% of this rating. If tripping is required at 115% of NEC motor full load current rating, set the overload dial to value 0.92 times F.L.C. value.

Two overload panels: Each overload dial is set at a value equal to one half of NEC motor full load current rating and will trip at 125% of the setpoint. If tripping is required at 115% of NEC motor full load current rating, set each overload dial to value of 0.92 times one half of F.L.C. value.

FEATURES:

ETL APPROVED

OIL PRESSURE SAFETY SWITCH protects compressor against damage from low oil pressure.

TIME GUARD circuit protects compressor and motor against short cycling.

OVERLOAD RELAY* manual reset.

SUCTION, DISCHARGE, OIL PRESSURE GAUGES display operating conditions.

GAUGE SHUTOFF VALVES

CAPILLARIES supplied for pressure gauges and switches.

CONTACTORS

TERMINAL BLOCKS for field connections.

GROUNDING LUG

CRANKCASE HEATER RELAY energizes heater on compressor shutdown to prevent dilution of oil by refrigerant.

PUMPOUT RELAY safeguards compressor against liquid refrigerant slug-ging on start-up.

ELAPSED RUNNING TIME METER

WIRE ASSEMBLIES provided in conduit are used to connect panel box and external controls to a junction box (provided).

FUSE, ON-OFF SWITCH, NEMA ENCLOSURE

HINGED COVER

HEAVY DUTY PANEL MOUNTING BASE is provided. Can be welded to compressor base or attached with supplied hardware.

P101

94

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

CONTROL PANELS

*From the National Electrical Code based on motor horsepower and voltage.†AC3 rating is an IEC (International Electrical Code) rating per U.L. standards. The contactors supplied with the panels are not definite purpose contactors.

They are specific to motor switching circuits.NOTE: The information presented in the table above is for the current control panels offered through RCD.

MOTOR CONTACTOR OVERLOAD LUG WIRERANGE(AWG)

APPROX.SHIP. WT

(lbs)

CONTROLPANEL

P/NHP NEC Amps(FLA)* Volts Rating

(AC3)† Qty AmpRange Qty

5 17.5 208 28 1 13-19 1 12-8 115 32CF131A45 15.2 230 17 1 13-19 1 18-10 115 32CF131A55 7.6 460 9 1 6-8.5 1 18-10 115 32CF131A65 6.1 575 9 1 4.5-6.5 1 18-10 115 32CF131A1

7.5 25 208 28 1 24-32 1 12-8 115 32CF132B47.5 22 230 28 1 18-25 1 12-8 115 32CF132B57.5 11 460 11 1 10-14 1 18-10 115 32CF131B67.5 9 575 9 1 7.5-11 1 18-10 115 32CF131B110 32 208 32 1 29-42 1 8-4 115 32CF142C410 28 230 32 1 24-32 1 8-4 115 32CF142C510 14 460 17 1 13-19 1 18-10 115 32CF131C610 11 575 11 1 10-14 1 18-10 115 32CF131C115 48 208 54 1 36-52 1 8-1 115 32CF153D415 42 230 41 1 36-52 1 8-1 115 32CF153D515 21 460 28 1 18-25 1 12-8 115 32CF132D615 17 575 17 1 13-19 1 18-10 115 32CF131D120 62 208 65 1 45-63 1 8-1 115 32CF242E420 54 230 54 1 45-63 1 8-1 115 32CF242E520 27 460 32 1 24-32 1 8-4 115 32CF142E620 22 575 28 1 18-25 1 12-8 115 32CF142E125 78 208 80 1 60-80 1 8-1 130 32CF243F425 68 230 80 1 60-80 1 8-1 130 32CF242F525 34 460 41 1 29-42 1 8-4 115 32CF152F625 27 575 28 1 24-32 1 12-8 115 32CF152F130 92 208 95 1 80-110 1 6-2/0 130 32CF253G430 80 230 80 1 60-80 1 8-1 130 32CF243G530 40 460 41 1 29-42 1 8-4 115 32CF231G630 32 575 32 1 29-42 1 8-4 115 32CF141G140 120 208 130 1 100-135 1 8-3/0 130 32CF263H440 104 230 110 1 80-110 1 6-2/0 130 32CF263H540 52 460 54 1 45-63 1 8-1 115 32CF242H640 41 575 41 1 29-42 1 8-4 115 32CF241H150 150 208 156 1 130-175 1 8-250MCM 130 32CG273J450 130 230 130 1 100-135 1 8-3/0 130 32CG273J550 65 460 65 1 60-80 1 8-1 130 32CF242J650 52 575 54 1 45-63 1 8-1 115 32CF242J160 177 208 192 1 150-200 1 6-250MCM 130 32CH295K460 154 230 156 1 130-175 1 8-250MCM 130 32CH295K560 77 460 80 1 60-80 1 8-1 130 32CF253K660 62 575 65 1 60-80 1 8-1 130 32CF252K175 221 208 242 1 220-310 1 4-500MCM 130 32CH205L475 192 230 192 1 150-200 1 6-250MCM 130 32CH205L575 96 460 11 1 80-110 1 6-2/0 130 32CF263L675 77 575 95 1 80-110 1 6-2/0 130 32CF263L1

100 285 208 156 2 110-150 2 6-350MCM 130 32CI216M4100 248 230 130 2 100-135 2 6-350MCM 130 32CI216M5100 124 460 130 1 100-135 1 8-3/0 130 32CH274M6100 99 575 110 1 80-110 1 6-2/0 130 32CF273M1125 358 208 192 2 150-200 2 6-350MCM 130 32CI227N4125 312 230 156 2 130-175 2 6-350MCM 130 32CI227N5125 156 460 156 1 130-175 1 8-250MCM 130 32CI205N6125 125 575 130 1 100-135 1 8-3/0 130 32CI225N1150 415 208 242 2 165-235 2 2-600MCM 130 32CJ217P4150 360 230 192 2 150-200 2 6-350MCM 130 32CJ227P5150 180 460 192 1 150-200 1 6-250MCM 130 32CJ205P6150 144 575 156 1 110-150 1 8-250MCM 130 32CJ284P1200 550 208 302 2 220-310 2 2-600MCM 130 32CJ218Q4200 480 230 242 2 220-310 2 2-600MCM 130 32CJ218Q5200 240 460 242 1 220-310 1 4-500MCM 130 32CJ216Q6200 192 575 192 1 150-200 1 6-250MCM 130 32CJ205Q1

95

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

COMPRESSOR TO DRIVE MOTOR COMBINATIONS

MOTORS

5H COMPRESSOR/MOTOR COMBINATIONSCOMPRESSOR

MODELMOTOR H.P RATING

5H40 20,25,30,40,505H46* 25,30,35,40,50,605H60 30,40,50,60,755H66* 40,50,60,75,1005H80 40,50,60,75,1005H86* 50,60,75,100,1255H120* 60,75,100,125,1505H126* 75,100,125,150,200

Motor selection is based on compressor rating charts.

NOTE: Extended stroke compressors (5H46,66,86,126) should not be applied on belt drive applications.

5F COMPRESSOR/MOTOR COMBINATIONSCOMPRESSOR

MODELMOTOR H.P. RATING

5F20 5,7.5,105F30 7.5,10,155F40 7.5,10,15,20,255F60 10,15,20,25,30

DRIP-PROOF

(1) Motors rated 208-230/460 will operate at 208 volts. At 208 volts, motor may not meet NEMA specifications.

NOTE: Order these by description.

H.P. SPEED VOLTAGE(1) FRAME P/N

51800 200-208 184T 240-1391800 208-230/460 184T 240-138

7.51800 200-208 213T 240-1471800 208-230/460 213T 240-146

101800 200-208 215T 240-1551800 208-230/460 215T 240-154

151800 200 254T 240-1631800 208/230/460 254T 240-162

201800 200-208 256T 240-1711800 230/460 256T 240-170

251800 208/230/460 284T 240-1791800 230/460 284T 240-178

301800 200-208 286T 240-1891800 2081230/460 286T 240-188

401800 200-208 324T 240-1971800 230/460 324T 240-196

501800 200-208 326T 240-2051800 230/460 326T 240-204

601800 200-208 364T 240-2131800 230/460 364T 240-212

751800 200-208 365T 240-2211800 230/460 365T 240-220

1001800 200-208 404T 240-2311800 230/460 404T 240-230

125 1800 460 405T 240-240150 1800 460 444TS See Note200 1800 460 445TS See Note

• 3 Phase, 60 Hertz• 40° C Ambient• Nema Design B• 1.15 Service Factor• Class B Insulation• Continuous Duty• F1 Assembly

TOTALLY ENCLOSED, FAN COOLED• 3 Phase, 60 Hertz• 40° C Ambient• Nema Design B• 1.15 Service Factor• Class B Insulation• Continuous Duty• F1 Assembly

*230 volt motors operational on 208 volt network.

NOTE: Order these by description.

H.P. SPEED VOLTAGE* FRAME P/N

51800 200-208 184T 241-1391800 230/460 184T 241-138

101800 200-208 215T 241-1551800 230/460 215T 241-454

151800 200-208 254T 241-4631800 230/460 254T 241-462

201800 200-208 256T 241-4711800 230/460 256T 241-170

251800 200-208 284T 241-4791800 230/460 284T 241-478

301800 200-208 286T 241-4891800 230/460 286T 241-488

401800 200-208 324T 241-4971800 230/460 324T 241-496

501800 200-208 326T 241-2051800 230/460 326T 241-204

601800 200-208 364T 241-2131800 230/460 364T 241-212

751800 200-208 365T 241-2211800 230/460 365T 241-220

1001800 200-208 405T 241-2311800 230/460 405T 241-230

125 1800 460 444TS See Note150 1800 460 445TS See Note200 1800 460 445T 241-258

P183

P184

96

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

DIRECT DRIVE UNIT BASES

MOTOR DRILLING CODE CHART

(*)Select motor drilling from chart above to complete part number.For example, when 5F20-515A is selected the base will be drilled to accept a 5 H.P., 184T frame motor.

†5H66, 80, 86 with 100 H.P. motor and 5H86 with 125 H.P. motor require (2) 5H40-1422 compressor blocks.

NOTE: For base drilling code selections “H” thru “N”, an “S” placed at the end of the part number indicates a base drilling for a short shaft motor/TS frame. (For example, P/N 5H40-588HS is a 5H40-588 base drilled to accept a 324TS frame motor.)

CODE H. P. FRAME CODE H.P. FRAME CODE H. P. FRAMEA 5 184T F 25 284T L 75 365TB 7.5 213T G 30 286T M 100 404TC 10 215T H 40 324T N 125 405TD 15 254T J 50 326T O 150 444TSE 20 256T K 60 364T P 200 445TS

COMPRESSOR USED WITHMOTOR DRILLING

SELECTIONBASE SIZE (L x W x H)

APPROX. BASE WEIGHT(lbs)

DIRECT DRIVE UNIT BASEP/N

5F20 A,B,C 37 x 16 x 11 2005F20-515(*)

5F30 B,C,D 37 x 16 x 11 2005F40 B,C,D,E,F 48 x 22 x 6 250

5F40-398(*)5F60 C,D,E,F,G 48 x 22 x 6 2505H40 E,F,G,H,J 56 x 25 x 8 400

5H40-588(*)5H46 F,G,H,J,K 56 x 25 x 8 4005H60 G,H,J,K,L 56 x 25 x 8 4005H66 H,J,K,L,M† 56 x 25 x 8 4005H80 H,J,K,L,M 75 x 32 x 10 800

5H80-588(*)5H86 J,K,Mt,Nt 75 x 32 x 10 800

5H120 K,L,M,N,O 75 x 32 x 10 8005H126 L,M,N,O,P 75 x 32 x 10 800

• Heavy duty channeled steel base• Coupling guard included• Motor and compressor mounting holes are

predrilled. Select motor drilling code from the chart below:

B110-1

97

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

BELT DRIVE UNIT BASES

ADJUSTABLE MOTOR BASE CODE CHART

(*)Select adjustable base code from chart above to complete part number.For example, when 5F20-238A is selected the adjustable motor base will accept a 5 H.P., 184T frame motor.

CODE H. P. FRAME CODE H. P. FRAME CODE H.P. FRAMEA 5 184T F 25 284T L 75 365TB 7.5 213T G 30 286T M 100 404TC 10 215T H 40 324T N 125 405TD 15 254T J 50 326TE 20 256T K 60 364T

COMPRESSOR USED WITHADJUSTABLE MOTOR

BASEBASE SIZE (L x W x H)

APPROX. BASE WEIGHT (lbs)

BELT DRIVE UNIT BASE P/N

5F20 A, B,C 37 x 16 x 11 1505F20-238(*)

5F30 B,C, D 37 x 16 x 11 1505F40 B,C,D,E,F 48 x 22 x 6 250

5F40-408(*)5F60 C,D,E,F,G 48 x 22 x 6 2505H40 E,F,G,H,J 56 x 25 x 8 440

5H40-598(*)5H60 G,H,J,K,L 56 x 25 x 8 4405H80 H,J,K,L,M 75 x 32 x 10 625

5H60-974(*)5H120 K,L,M,N 75 x 32 x 10 625

• Heavy duty channeled steel base• Belt guard included.• Compressor mounting holes are

predrilled.• An adjustable steel motor base

facilitates motor positioning. Select adjustable motor base from the chart below:

B111-1

98

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

FLYWHEEL, PULLEY, BELTS

PD - Pitch Diameter (in.)

PL - Pitch Length (in.)

COM-PRESSOR

MODEL

MOTOR H. P.

MOTOR FRAME

SIZE

MOTOR SHAFT

DIA. (in.)

COM-PRESSOR

RPM

CENTER TO

CENTER (in.)

FLYWHEEL PULLEY BELTS

P/N PDNO. OF

GROOVES & TYPE

P/N PDNO. OF

GROOVES & TYPE

P/N PL NO. OF BELTS

5F20 5 184T 1-1/8 1750 19.3 5F20-394 7.5 2-B 5F20-861 7.4 2-B 5F20-851 61.8 2-B5F20 7.5 213T 1-3/8 1750 19.3 5F20-394 7.5 2-B 5F20-891 7.4 2-B 5F20-851 61.8 2-B5F20 10 215T 1-3/8 1750 19.3 5F20-394 7.5 2-B 5F20-891 7.4 2-B 5F20-851 61.8 2-B5F30 7.5 213T 1-1/8 1750 19.3 5F20-394 7.5 2-B 5F20-891 7.4 2-B 5F20-851 61.8 2-B5F30 10 215T 1-3/8 1750 19.3 5F20-394 7.5 2-B 5F20-891 7.4 2-B 5F20-851 61.8 2-B5F30 15 254T 1-5/8 1750 19.3 5F30-394 7.5 3-B 5F30-921 7.4 3-B 5F30-831 61.8 3-B5F40 7.5 213T 1-5/8 1750 26.6 5F40-394 9.5 3-B 5F30-881 9.4 3-B 5F40-841 82.8 3-B5F40 10 215T 1-3/8 1750 26.6 5F40-394 9.5 3-B 5F30-881 9.4 3-B 5F40-841 82.8 3-B5F40 15 254T 1-5/8 1750 26.6 5F40-394 9.5 3-B 5F40-871 9.4 3-B 5F40-841 82.8 3-B5F40 20 256T 1-5/8 1750 26.6 5F40-394 9.5 3-B 5F40-871 9.4 3-B 5F40-841 82.8 3-B5F40 25 284T 1-7/8 1750 26.6 5F40-394 9.5 3-B 5F40-881 9.4 3-B 5F40-841 82.8 3-B5F60 10 215T 1-3/8 1750 26.6 5F40-394 9.5 3-B 5F30-881 9.4 3-B 5F40-841 82.8 3-B5F60 15 254T 1-5/8 1750 26.6 5F40-394 9.5 3-B 5F40-871 9.4 3-B 5F40-841 82.8 3-B5F60 20 256T 1-5/8 1750 26.6 5F40-394 9.5 3-B 5F40-871 9.4 3-B 5F40-841 82.8 3-B5F60 25 284T 1-7/8 1750 26.6 5F40-394 9.5 3-B 5F40-881 9.4 3-B 5F40-841 82.8 3-B5F60 30 286T 1-7/8 1750 26.6 5F40-394 9.5 3-B 5F40-881 9.4 3-B 5F40-841 82.8 3-B5H40 20 256T 1-5/8 1750 32.2 5H40-394 11.0 3-C 5H40-811 11.0 3-C 5H40-861 92.9 3-C5H40 25 284T 1-7/8 1750 32.2 5H40-394 11.0 3-C 5H80-811 11.0 3-C 5H40-861 98.9 3-C5H40 30 286T 1-7/8 1750 32.2 5H40-394 11.0 3-C 5H80-811 11.0 3-C 5H40-861 98.9 3-C5H40 40 324T 2-1/8 1750 32.2 5H40-394 11.0 3-C 5H40-821 11.0 3-C 5H40-861 98.9 3-C5H40 50 326T 2-1/8 1750 32.2 5H40-394 11.0 3-C 5H40-821 11.0 3-C 5H40-861 98.9 3-C5H60 30 286T 1-7/8 1750 32.2 5H40-394 11.0 3-C 5H80-811 11.0 3-C 5H40-861 98.9 3-C5H60 40 324T 2-1/8 1750 32.2 5H40-394 11.0 3-C 5H40-821 11.0 3-C 5H40-861 98.9 3-C5H60 50 326T 2-1/8 1750 32.2 5H60-394 11.0 5-C 5H80-821 11.0 5-C 5H120-861 98.9 5-C5H60 60 364T 2-3/8 1750 32.2 5H60-394 11.0 5-C 5H120-821 11.0 5-C 5H120-861 98.9 5-C5H60 75 365T 2-3/8 1750 32.2 5H40-394 11.0 5-C 5H120-821 11.0 5-C 5H120-861 98.9 5-C5H80 40 324T 2-1/8 1750 36.7 5H60-394 11.0 5-C 5H80-821 11.0 5-C 5H40-871 107.9 5-C5H80 50 326T 2-1/8 1750 36.7 5H60-394 11.0 5-C 5H80-821 11.0 5-C 5H40-871 107.9 5-C5H80 60 364T 2-3/8 1750 36.7 5H60-394 11.0 5-C 5H120-821 11.0 5-C 5H40-871 107.9 5-C5H80 75 365T 2-3/8 1750 36.7 5H60-394 11.0 5-C 5H120-821 11.0 5-C 5H40-871 107.9 5-C5H80 100 404T 2-7/8 1750 36.7 5H120-394 11.0 9-C 5H120-831 11.0 9-C 5H120-871 107.9 9-C

5H120 60 364T 2-3/8 1750 36.7 5H60-394 11.0 5-C 5H120-821 11.0 5-C 5H40-871 107.9 5-C5H120 75 365T 2-3/8 1750 36.7 5H60-394 11.0 5-C 5H120-821 11.0 5-C 5H40-871 107.9 5-C5H120 100 404T 2-7/8 1750 36.7 5H120-394 11.0 9-C 5H120-831 11.0 9-C 5H120-871 107.9 9-C5H120 125 405T 2-7/8 1750 36.7 5H120-394 11.0 9-C 5H120-831 11.0 9-C 5H120-871 107.9 9-C

P95 P96 P97

99

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

DIMENSIONAL AND PHYSICAL DATA FOR COMPRESSOR UNITS

MOTOR-COMPRESSOR UNIT6G

06LH

009 109 209 014 114 214 018 118 218 028 128 228

40 45 60 63 65 6L40 6L43 6L45 6L60 6L63 6L65 6L80 6L83 6L85 6L120 6L123 6L125

DIMENSIONS*

*All dimensions are in inches. Dimensions shown are approximate. Certified dimension prints are available on request.

A 31-7/8 31-7/8 33-1/8 33-1/8 33-1/8 39-1/2 39-1/2 39-1/2 41-1/2 41-1/2 41-1/2 56-7/8 56-7/8 56-7/8 60 60 60

B 21-1/8 21-1/8 23 23 23 28-5/8 28-5/8 28-5/8 29-1/8 29-1/8 28-3/8 28-3/8 28-3/8 28-3/8 29-1/4 29-1/4 29-1/4

C 18-5/8 18-5/8 19-3/4 19-3/4 19-3/4 25-7/8 25-7/8 25-7/8 28-7/8 28-7/8 28-7/8 29-1/2 29-1/2 29-1/2 33-3/8 33-3/8 33-3/8

D 19-1/8 19-1/8 19-1/8 19-1/8 19-1/8 25-3/8 25-3/8 25-3/8 25-3/8 25-3/8 25-3/8 35-7/8 35-7/8 35-7/8 35-7/8 35-7/8 35-7/8

E 11 11 11 11 11 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2

F 21-7/8 21-7/8 21-7/8 21-7/8 21-7/8 26-3/8 26-3/8 26-3/8 26-3/8 26-3/8 26-3/8 37-1/2 37-1/2 37-1/2 37-1/2 37-1/2 37-1/2

G 18-1/4 18-1/4 18-1/4 18-1/4 18-1/4 27 27 27 27 27 27 32-1/2 32-1/2 32-1/2 32-1/2 32-1/2 32-1/2

COMPRESSOR MOUNTING HOLES (Dia.)

H 9/16 9/16 5/16 9/16 9/16 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4

MOUNTING RAIL HOLES (Dia.)

J 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16 9/16

SUCTION VALVE (ODF) K 1-5/8 1-5/8 2-1/8 2-1/8 2-1/8 2-1/8 2-5/8 2-5/8 3-1/8 3-1/8 3-1/8 4-1/8 4-1/8 4-1/8 4-1/8 4-1/8 4-1/8

DISCHARGE VALVE (ODF) L 1-1/8 1-1/8 1-3/8 1-3/8 1-3/8 1-5/8 1-5/8 1-5/8 2-1/8 2-1/8 2-1/8 3-1/8 3-1/8 3-1/8 3-1/8 3-1/8 3-1/8

NET WEIGHT (lbs) 480 546 690 730 760 1040 1080 1145 1310 1410 1500 1830 1870 1890 2150 2190 2220

RATINGS AT 40F SATURATED

SUCTION TEMP. AND 105F

CONDENSING TEMP. (Tons)**

**These are saturation temperatures corresponding to the actual suction and discharge pressures at the compressor.†Refrigerants 12, C-500 and 22 are suitable for use in any of the units as long as motor kW limitations are not exceeded.‡These rating points are in accordance with ASRE Standard 23-R, “Methods of Rating and Testing Motor Compressor Units.”

††For 1450 rpm, reduce capacity, and power input to 83% of 1750 rpm valves.‡‡ “Net” Oil Pressure = Oil Pressure Gauge Reading – Suction Pressure.

REFRIGERANT 12†

10.8 10.8 16.2 16.2 25.6 25.6 38.4 38.4 51.2 51.2 76.8 76.8

CARRENE 500† 12.7 12.7 19.0 30.2 30.2 45.3 45.3 60.4 60.4 90.6 90.6

REFRIGERANT 22†

17.1 25.6 39.8 59.6 59.6 79.5 119.4

NUMBER Of CYLINDERS 4 4 6 6 6 4 4 4 6 6 6 8 8 8 12 12 12

BORE, INCHES 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4

STROKE, INCHES 2 2 2 2 2 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4

DISPLACEMENT, CFM AT1750 RPM

39.8 39.8 59.6 59.6 59.6 92.4 92.4 92.4 138.4 138.4 138.4 184.8 184.8 184.8 276.8 276.8 276.8

ASRE RATINGS‡(Tons) at

1750 RPM††

GROUP III (20 and

105)**

REFRIGERANT 12

6.7 6.7 10.0 10.0 15.8 15.8 23.8 23.8 31.6 31.6 47.5 47.5

CARRENE 500 7.8 7.8 11.6 18.3 18.3 27.6 27.6 36.8 36.8 55.1 55.1

GROUP VII (20

and 100)**

REFRIGERANT 22

10.6 16.0 16.0 25.4 25.4 38.1 38.1 50.8 76.4

GROUP IV (40 and

110)**

REFRIGERANT 12

10.1 10.1 15.2 15.2 24.0 24.0 35.8 35.8 48.0 48.0 71.8 71.8

CARRENE 500 11.9 18.8 28.2 42.3 42.3 56.3 56.3 84.6

GROUP VIII (40

and 100)**

REFRIGERANT 22

17.2 25.7 25.7 40.3 40.3 60.3 60.3 80.5 120.4

SPEED, RPM (60 Cycle) 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750

MINIMUM NET OIL PRESSURE FOR UNLOADER OPERATION (PSI)‡‡

35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35

RECOMMENDED NET OILPRESSURE AT

1750 RPM (PSI)40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60 40-60

NORMAL OIL LEVEL IN SIGHT-GLASS CENTER LINE

FACTORY OIL CHARGE (Pints) 18 18 20 20 20 30 30 30 47 47 47 80 80 80 90 90 90

100

CARLYLE OPEN DRIVE COMPRESSORS

6L, 06L REPLACEMENT COMPRESSOR AND MOTOR GROUP

FORMER 6LMODEL SIZE

CURRENT 06LMODEL SIZE

REPLACEMENT COMPRESSORMODEL

6L40 06LA009 06LH0096L43 06LA109 06LH1096L45 06LA209 06LH2096L60 06LA014 06LH0146L63 06LA114 06LH1146L65 06LA214 06LH2146L80 06LA018 06LH0186L83 06LA118 06LH1186L85 06LA218 06LH218

6L120 06LA028 06LH0286L123 06LA128 06LH1286L123*

*10 Cylinder Compressor.

06LA123 06LH1236L125 06LA228 06LH228

101

CARLYLE OPEN DRIVE COMPRESSORS

06L PERFORMANCE DATA COMPRESSOR CAPACITIES (60 Hz)

SST SDTR-500 R-22

06LH214 06LH218 6LH228 06LH214 06LH218 06LH228Cap. Kw THR Cap. kW THR Cap. kW THR Cap. kW THR Cap. kW THR Cap. kW THR

10

90 25.0 27.2 32.8 33.8 36.4 44.1 49.9 53.9 65.3 35.2 36.2 45.5 45.8 47.0 59.2 65.8 73.4 86.7100 22.8 28.3 30.8 30.5 38.0 41.3 45.3 56.4 61.3 32.4 38.1 43.2 42.0 50.0 56.2 60.8 76.8 82.7105 21.6 28.8 29.9 28.9 38.6 39.9 43.1 57.3 59.4 31.0 38.8 42.0 - - - 58.4 78.4 80.7110 20.6 29.2 28.9 - - - 40.9 58.1 57.4 29.5 39.3 40.8 - - - 56.0 79.9 78.8120 18.4 29.8 26.9 - - - 36.6 58.9 53.4 - - - - - - - - -130 16.3 29.9 24.9 - - - 32.4 58.7 49.2 - - - - - - - - -

20

90 32.5 30.3 41.1 43.5 40.4 55.0 64.8 60.0 81.9 45.1 38.8 56.1 58.4 49.6 72.5 85.9 78.5 108.2100 29.9 32.1 39.0 39.9 42.8 52.0 59.6 63.7 77.7 41.9 41.6 53.7 54.1 53.9 69.5 80.0 83.6 103.8105 28.6 32.8 37.9 38.1 43.8 50.5 57.0 65.2 75.6 40.2 42.8 52.4 51.9 56.1 67.9 77.0 86.1 101.5110 27.3 33.5 36.9 36.3 44.7 49.0 54.4 66.6 73.4 38.6 43.8 51.1 49.7 58.1 66.2 74.1 88.5 99.3120 24.7 34.7 34.6 32.7 46.3 45.8 49.3 68.8 68.9 35.3 45.6 48.3 - - - 67.8 92.7 94.2130 22.1 35.4 32.2 - - - 44.1 70.1 64.1 32.2 46.8 45.5 - - - 60.7 95.6 88.0140 19.5 35.8 29.7 - - - 38.8 70.5 58.9 - - - - - - - - -

30

90 40.9 33.0 50.3 54.6 43.8 67.0 81.7 65.1 100.2 56.3 40.7 67.9 72.9 50.9 87.4 108.8 81.5 132.0100 38.0 35.3 48.1 50.6 46.9 64.0 75.9 69.9 95.8 52.6 44.3 65.2 68.1 56.6 84.3 101.9 88.5 127.1105 36.6 36.4 46.9 48.6 48.4 62.4 73.0 72.1 93.5 50.7 46.0 63.8 65.7 59.5 82.6 98.4 92.0 124.6110 35.1 37.4 45.7 46.6 49.7 60.7 70.0 74.2 91.2 48.9 47.6 62.4 63.1 62.4 80.8 94.8 95.4 121.9120 32.1 39.2 43.2 42.5 52.3 57.4 64.1 77.8 86.3 45.1 50.4 59.4 57.7 67.8 77.0 87.0 101.6 116.0130 29.0 40.6 40.5 38.3 54.5 53.8 58.0 80.7 81.0 41.3 53.0 56.4 52.1 72.4 72.7 78.4 106.8 108.8135 27.4 41.1 39.0 36.1 55.4 51.9 54.8 77.9 81.9 39.5 54.1 54.9 49.1 74.2 70.3 73.6 108.7 104.5140 25.8 41.6 37.6 33.9 56.4 50.0 51.6 75.1 82.8 - - - - - - - - -

40

90 50.2 34.9 60.2 67.0 46.3 80.2 100.4 68.8 120.0 68.9 41.7 80.8 89.5 50.9 104.0 134.4 82.3 157.8100 47.1 37.9 57.9 62.7 50.2 77.0 94.1 74.9 115.4 64.7 46.2 77.8 84.1 57.9 100.6 126.3 91.2 152.3105 45.5 39.3 56.6 60.5 52.1 75.4 90.9 77.8 113.0 62.5 48.3 76.3 81.3 61.6 98.8 122.2 95.8 149.4110 43.8 40.6 55.4 58.3 54.0 73.6 87.6 80.6 110.5 60.3 50.4 74.7 78.3 65.3 96.9 117.8 100.2 146.4120 40.4 43.1 52.7 53.7 57.5 70.1 80.9 85.7 105.3 56.0 54.4 71.4 72.2 72.6 92.9 108.6 108.7 139.5130 36.8 45.2 49.7 48.9 60.8 66.2 73.9 90.2 99.6 51.6 58.1 68.1 65.7 79.3 88.3 98.2 116.2 131.3135 34.9 46.1 48.0 46.5 62.3 64.1 70.2 92.1 96.4 49.4 59.9 66.4 62.3 82.3 85.8 92.5 119.4 126.5140 33.1 46.9 46.4 43.9 63.9 62.1 66.5 94.0 93.2 - - - - - - - - -

44

90 54.2 35.4 64.3 72.3 47.0 85.7 108.3 69.8 128.2 74.3 41.8 86.2 96.7 50.5 111.1 145.3 81.9 168.6100 51.0 38.7 62.0 67.9 51.3 82.5 101.8 76.5 123.6 69.8 46.6 83.1 91.0 58.1 107.6 136.7 91.7 162.8105 49.3 40.2 60.7 65.6 53.4 80.8 98.5 79.7 121.2 67.6 49.0 81.5 88.1 62.1 105.7 132.3 96.6 159.8110 47.6 41.7 59.4 63.3 55.4 79.1 95.1 82.7 118.7 65.3 51.2 79.9 85.0 66.1 103.8 127.7 101.5 156.6120 44.0 44.4 56.6 58.6 59.3 75.5 88.1 88.5 113.3 60.6 55.6 76.5 78.5 74.2 99.7 117.8 111.0 149.4130 40.2 46.8 53.6 53.6 63.0 71.5 80.8 93.7 107.4 56.0 59.9 73.0 71.7 81.7 94.9 106.7 119.4 140.7135 38.2 47.0 51.9 40.8 64.8 69.9 76.9 95.9 104.1 53.6 61.9 71.3 68.1 85.2 92.3 100.6 123.1 135.6140 36.3 48.8 50.2 48.3 66.6 67.3 73.0 98.2 100.9 - - - - - - - - -

102

CARLYLE OPEN DRIVE COMPRESSORS

06L PERFORMANCE DATA COMPRESSOR CAPACITIES (60 Hz)

– Spaces noted by a dash indicate maximum compressor power is exceeded.

NOTES:1. Capacities are based on 1750 rpm and 15 F subcooling. 2. Liquid subcooling, greater than (less than) the 15 F incorporated in the ratings, increases (decreases) system capacity by 1.2 of 1% for each degree of

subcooling. When correcting for subcooling, power input does not change. Adjusted total heat rejection (tons) equals adjusted capacity + .285 x kW input.

3. Refrigerant temperatures shown are saturation temperatures corresponding to pressures indicated at compressor. Actual gas temperatures are higher because of superheat.

4. Capacities are based on actual suction gas temperatures to the compressor of 65 F for R-500. (This assumes superheat is obtained from liquid-suction interchanger or in evaporator.)

Capacity corrections, for other than rated suction gas temperatures, may be obtained from Capacity Multipliers table. R-22 suction gas superheat for ratings (15 F) normally occurs because of expansion valve operation and line losses. Therefore R-22 ratings can be used without adjustment.

SST SDTR-500 R-22

06LH214 06LH218 6LH228 06LH214 06LH218 06LH228Cap. kW THR Cap. kW THR Cap. kW THR Cap. kW THR Cap. kW THR Cap. kW THR

48

90 58.3 35.8 68.5 77.9 47.6 91.4 116.6 70.6 136.7 79.9 41.8 91.8 104.3 49.8 118.5 156.5 81.1 179.6100 55.0 39.3 66.2 73.3 52.2 88.2 109.9 77.8 132.0 75.2 46.9 88.6 98.3 58.0 114.8 147.5 91.7 173.6105 53.2 41.0 64.9 71.0 54.4 86.5 106.4 81.3 129.6 72.8 49.4 86.9 95.2 62.3 112.9 142.8 97.1 170.4110 51.4 42.6 63.6 68.6 56.7 84.8 102.9 84.7 127.0 70.4 51.9 85.2 91.9 66.7 110.9 137.8 102.5 167.0120 47.7 45.6 60.7 63.7 61.0 81.0 95.6 91.1 121.6 65.5 56.7 81.6 85.1 75.5 106.6 127.3 112.8 159.4130 43.8 48.3 57.5 58.4 65.1 77.0 87.9 96.9 115.5 60.6 61.4 78.0 77.9 83.9 101.8 115.4 122.3 150.2135 41.7 49.4 55.7 55.6 67.1 74.8 83.8 99.5 112.1 58.1 63.7 76.2 74.1 87.8 99.1 108.9 126.5 144.9140 39.6 50.6 54.0 52.9 69.2 72.6 79.7 102.2 108.8 - - - - - - - - -

50

90 60.4 35.9 70.6 80.7 47.8 94.3 120.8 70.9 140.9 82.8 41.7 94.7 108.2 49.4 122.2 163.3 80.5 185.2100 57.0 39.6 68.3 76.1 52.6 91.1 114.0 78.4 136.3 78.0 47.0 91.4 102.1 57.9 118.5 153.0 91.5 179.0105 55.2 41.3 67.0 73.8 54.9 89.4 110.5 82.0 133.9 75.5 49.6 89.6 98.8 62.3 116.6 148.1 97.2 175.8110 53.4 43.0 65.7 71.3 57.2 87.6 106.9 85.5 131.3 73.0 52.1 87.9 95.5 66.9 114.6 143.0 102.8 172.3120 49.6 46.2 62.8 66.3 61.7 83.9 99.5 92.3 125.8 68.0 57.2 84.3 88.6 76.1 110.2 132.1 113.6 164.5130 45.6 49.0 59.6 61.0 66.1 79.8 91.6 98.5 119.7 62.9 62.1 80.6 81.1 84.9 105.3 119.9 123.6 155.1135 43.4 50.2 57.8 58.1 68.2 77.6 87.4 101.3 116.3 60.4 64.6 78.7 - - - 113.2 128.1 149.6140 41.3 51.4 56.0 55.3 70.4 75.4 83.3 104.1 112.9 - - - - - - - - -

Cap. — CapacitykW — Power InputSDT — Saturated Discharge TemperatureSST — Saturated Suction TemperatureTHR — Total Heat Rejection (tons)

103

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

06LH OUTLINE DRAWINGSNOTE: COMPRESSORS SHOWN WITH OPTIONAL ACCESSORIES - CONTACT YOUR DISTRIBUTOR FOR DETAILS.

06LH109 & 209 COMPRESSORS

06LH114, 214 COMPRESSOR

NOTES:1. OIL PUMP IS AUTOMATICALLY REVERSIBLE FOR

EITHER DIRECTION OF ROTATION.2. NET WEIGHT INCLUDES MOTOR, COMPRESSOR

UNIT ASSEMBLY AS SHOWN, LESS REFRIGERANT.3. MOTOR FURNISHED WITH INTERNAL OVERHEAT

PROTECTION.

UNIT SIZE NET WEIGHT-LBS06LH109 108006LH209 1145

NOTES:1. OIL PUMP IS AUTOMATICALLY REVERSIBLE FOR EITHER

DIRECTION OF ROTATION.2. NET WEIGHT INCLUDES MOTOR, COMPRESSOR UNIT ASSEMBLY

AS SHOWN, LESS REFRIGERANT.3. SUCTION STRAINER MAY BE REMOVED FROM EITHER

HORIZONTAL DIRECTION. TO REMOVE IT FROM THE LEFT (VIEWED FROM PUMP END), REMOVE SUCTION STRAINER COVER. TO REMOVE IT FROM THE RIGHT, REMOVE SUCTION VALVE. SAME CLEARANCE REQUIRED EITHER DIRECTION. OBSERVE SAME CLEARANCE IF MOTOR END COVER IS ROTATED.

4. MOTOR FURNISHED WITH INTERNAL OVERHEAT PROTECTION.

UNIT SIZE NET WEIGHT-LBS06LH114 1410

06LH214 1500

104

CARLYLE OPEN DRIVE COMPRESSORS/ACCESSORIES

06LH OUTLINE DRAWINGSNOTE: COMPRESSORS SHOWN WITH OPTIONAL ACCESSORIES - CONTACT YOUR DISTRIBUTOR FOR DETAILS.

06LH118, 218 COMPRESSOR

06LH128, 228 COMPRESSOR

NOTES:1. OIL PUMP IS AUTOMATICALLY REVERSIBLE FOR EITHER DIRECTION OF

ROTATION.2. NET WEIGHT INCLUDES MOTOR, COMPRESSOR UNIT ASSEMBLY AS

SHOWN, LESS REFRIGERANT.3. SUCTION STRAINER MAY BE REMOVED FROM EITHER HORIZONTAL

DIRECTION. TO REMOVE IT FROM THE LEFT (VIEWED FROM PUMP END), REMOVE SUCTION STRAINER COVER. TO REMOVE IT FROM THE RIGHT, REMOVE SUCTION VALVE. SAME CLEARANCE REQUIRED EITHER DIRECTION. OBSERVE SAME CLEARANCE IF MOTOR END COVER IS ROTATED.

4. MOTOR FURNISHED WITH INTERNAL OVERHEAT PROTECTION.

UNIT SIZE NET WEIGHT-LBS06LH118 1850

06LH218 1890

NOTES:1. OIL PUMP IS AUTOMATICALLY REVERSIBLE FOR EITHER DIRECTION OF

ROTATION.2. NET WEIGHT INCLUDES MOTOR, COMPRESSOR UNIT ASSEMBLY AS

SHOWN, LESS REFRIGERANT.3. SUCTION STRAINER MAY BE REMOVED FROM EITHER HORIZONTAL

DIRECTION. TO REMOVE IT FROM THE LEFT (VIEWED FROM PUMP END), REMOVE SUCTION STRAINER COVER. TO REMOVE IT FROM THE RIGHT, REMOVE SUCTION VALVE. SAME CLEARANCE REQUIRED EITHER DIRECTION. OBSERVE SAME CLEARANCE IF MOTOR END COVER IS ROTATED.

4. MOTOR FURNISHED WITH INTERNAL OVERHEAT PROTECTION.

UNIT SIZE NET WEIGHT-LBS

06LH128 219006LH228 2220