Upload
cristofer-heredia
View
218
Download
0
Embed Size (px)
Citation preview
7/31/2019 Caracter i Sticas Cables
1/25
INDEX
External Network
Dry Core Cables
CTP-APL ........................................................................................................................................... CTS-APL ........................................................................................................................................... CTP-APL-AS ..................................................................................................................................... CTP-APL-SN ..................................................................................................................................... CCE-APL ...........................................................................................................................................
2 e 34 e 56 e 78 e 9
10 e 11
Gel Core Cable
CTP-APL-G ........................................................................................................................................ CTS-APL-G ............................................................................................................................................
CCE-APL-G ........................................................................................................................................
12 e 1314 e 15
16 e17
Internal Network
CIT ..................... ..................... ...................... ..................... ...................... ............................... .............. 18 e 19
Cable Forms .............................................................................................................................
Correction Factors.............................................................................................................Color Code ..................................................................................................................................
Others Products ....................................................................................................................
20 e 21
22
23 e 24
25
1
www.furukawa.com.br
URUKAF WABUILDING THE NETWORKS OF THE FUTURE
7/31/2019 Caracter i Sticas Cables
2/25
CTP-APL
Specification:ABNT NBR 9124 and Telebrs 235.320.701ANATEL Certification 46298-XXX-256
2
Electrical Characteristics
Conductor Diameter (mm) 0,40 0,50 0,65
Maximum Electrical Resistance (/km)
Resistive Unbalance (%)
MutualCapacitance (nF/km)
Average
CapacitanceUnbalance (pF/km)
P x P
P x T
Far EndCrosstalk Leak (dB/km)
150kHz
Near EndCrosstalk Leak (dB)
1024kHz
150kHz
1024kHz
AverageTransmissionAttenuation (dB/km)
Applied Voltage (V )cc
Max. Average
Max. Individual
20 p
> 20 p
Max. RMS
Max. Individual
Max. Average
Max. Individual
Max. RMS
Min. Individual
Min. RMS
Min. Individual
Min. Individual
Min. Individual
150 kHz
1024 kHz
C X C
C X B
12.0 8.0 6.0
26.0 20.4 16.0
2500 3000 3600
10000
147.2 94.0 55.8
2.0 1.5 1.5
5.0 5.0 4.0
46 ~56
48 ~54
45.3
181
574
2625
68
58
52
35
53
40
Overall Features
Specifications Value
Conductor Bare Copper
Conductor Diameter (mm)0.400.500.65
Number of Pairs 10 to 2400
Insulation Polyethylene or Polypropylene
Cladding Non-moisture Absorbing Tape(s)
External Sheath APL Sheath
* Other conductor diameters and cable composition available on inquiry.
Application:
The rigorous technical characteristics ofthis product allows transmitting analogand digital signals via high-ratestate-of-the-art transmission technologiessuch as ADSL, HDSL, VDSL, ISDN, etc.Provides a significant improvement in newservices, such as: multimedia, Internet,remote conferencing and voice over IP,among other. Its robust construction affordstotal protection from bad weather. Indicatedfor external networks as trunk, primary orsecondary cable, and can be installed inducts lines or overhead lines.
Description:
Telephone cable consisting of solidelectrolytic copper conductors.Thermoplastic insulation, grouped in pairs,core protected by an APL sheath.
7/31/2019 Caracter i Sticas Cables
3/25
External NetworkDry Core Cable
3
CTP-APL40
10 9.4 79 2000
20 10.7 114 2000
30 12.2 154 2000
50 14.2 223 2000
75 16.2 303 2000
100 17.2 378 2000
200 23.9 698 2000
300 28.8 1021 2000
400 31.8 1336 1000600 38.1 1965 1000
900 44.9 2850 500
1200 50.9 3739 500
1500 56.6 4623 400
1800 62.0 5004 400
2400 69.9 7274 400
CTP-APL50
10 10.7 101 2000
20 11.7 153 2000
30 13.9 212 200050 16.4 350 2000
75 19.1 400 2000
100 21.6 620 2000
200 28.8 1150 1000
300 34.6 1160 1000
400 38.6 2170 1000
600 46.1 2972 500
900 55.3 4359 400
1200 63.0 5765 400
1500 69.9 7159 400
CTP-APL65
10 11.7 150 2000
20 14.0 239 2000
30 16.1 324 2000
50 20.1 490 2000
75 23.6 739 2000
100 26.7 947 2000
200 36.9 1775 1000
300 44.1 2577 1000
400 50.3 3392 400
600 57.4 5031 400
900 71.2 7450 400
Size Characteristics
Number ofPairs
RatedExternalDiameter
(mm)
RatedNet Mass(kg/km)
RatedLength
(m)
Designation
7/31/2019 Caracter i Sticas Cables
4/25
CTS-APL
Application:
The use of Foam Skin insulation results ina lighter weight and more compact productas compared to CTP-APL cable. Allowstransmitting analog and digital signals via
high-rate-state-of-the-art transmissiontecnologies such as ADSL, HDSL, VDSL,ISDN, etc. Provides a significantimprovement in new services, such as:multimedia, lnternet, remote conferencingand voice over IP, among other. Its robustconstruction affords total protection frombad weather. Indicated for external networks,such as trunck, primary or secondary cable,and can be installed in ducted lines oroverhead lines.
Description:
Telephone cable consisting of solidelectrolytic copper conductors. Expandedthermoplastic insulation coated with a thinlayer of solid thermoplastic, grouped in pairs,core protected by an APL Sheath.
Specification:Telebrs 235.320.714, Furukawa PT 0480ANATEL Certification 47098-XXX256
4
Electrical Characteristics
Conductor Diameter (mm) 0.40 0.50
Maximum Electrical Resistance (/km)
Resistive Unbalance(%)
MutualCapacitance (nF/km)
Average
Far EndCrosstalk Leak (dB/km)
P x P
P x T
Near EndCrosstalk Leak (dB)
150kHz
TransmissionAttenuation (dB/km)
1024kHz
150kHz
1024kHz
Average
Applied Voltage (V )cc
Max. Average
Max. Individual
20 p
> 20 p
Max. RMS
Max. Average
Max. Individual
Min. RMS
Min. Individual
Min. RMS
Min. Individual
Min. Individual
Min. Individual
150 kHz
1024 kHz
C X C
C X B
12.0 8.0
26.0 20.4
1700 2000
10000
147.2 94.0
1.5
5.0
46 ~56
48 ~54
45.3
181
574
2625
68
58
52
53
40
Overall Features
Specifications Value
Conductor Bare Copper
Conductor Diameter (mm)0.400.50
Number of Pairs 10 to 2400
Insulation Foam Skin
Cladding Non-moisture Absorbing Tape(s)
External Sheath APL Sheath
* Other conductor diameters and cable composition available on inquiry.
2.0
CapacitanceUnbalance (pF/km)
Min. Individual
35
7/31/2019 Caracter i Sticas Cables
5/25
External NetworkDry Core Cable
5
Size Characteristics
Number ofPairs
RatedExternalDiameter
(mm)
RatedNet Mass(kg/km)
RatedLength
(m)
Designation
CTS-APL40
10 9.4 70 2000
20 10.7 111 2000
30 12.0 143 2000
50 13.5 213 2000
75 15.8 294 2000
100 17.4 372 2000
200 23.1 684 2000
300 27.8 1003 2000
400 30.8 1296 1000600 36.6 1904 1000
900 44.5 2827 500
1200 50.2 3682 500
1500 55.8 4563 400
1800 60.4 5366 400
2400 69.0 7146 400
CTS-APL50
10 10.5 88 2000
20 11.4 140 2000
30 13.5 189 200050 15.8 285 2000
75 18.0 406 2000
100 20.4 519 2000
200 27.3 958 1000
300 32.6 1400 1000
400 38.4 1809 1000
600 43.3 2642 400
900 53.8 3902 400
1200 61.3 5129 400
Conductor
Expanded PE(Plastic + Air)
Solid PE
7/31/2019 Caracter i Sticas Cables
6/25
CTP-APL-AS
Application:
The technical characteristics of this productallow transmitting analog and digital signalsvia high-rate-state-of-the-art transmission
technologies such as ADSL, HDSL, ISDN, etc.Provides a significant improvement in newservices, such as: multimedia, lnternet, remoteconferencing and voice over IP, among other.Its robust construction affords total protectionfrom bad weather. Indicated for externalnetworks as secondary cable, and can beinstalled in ducts or overhead lines.
Description:
Telephone cable consisting of solid electrolyticcopper conductors. Thermoplastic insulation,
grouped in pairs, core protected by a APLsheath. Supported by thermoplastic-coatedsteel cordage, fitted in parallel with theAPL sheath. Specification:
ABNT NBR 9889 and Telebrs 235.320.704ANATEL Certification 46398-XXX256
6
Overall Features
Specifications Value
Conductor Bare Copper
Conductor Diameter (mm)0.400.500.65
Number of Pairs 10 to 100
Insulation Polyethylene or Polypropylene
Cladding Non-moisture Absorbing Tape(s)
External Sheath APL Sheath
* Other conductor diameters and cable composition available on inquiry.
Electrical Characteristics
Conductor Diameter (mm) 0.40 0.50 0.65
Maximum Electrical Resistance (/km)
Resistive Unbalance (%)
MutualCapacitance (nF/km)
Average
CapacitanceUnbalance (pF/km)
P x P
P x T
Far EndCrosstalk Leak (dB/km)
150kHz
Near EndCrosstalk Leak (dB)
1024kHz
150kHz
1024kHz
AverageTransmissionAttenuation (dB/km)
Applied Voltage (V )cc
Max. Average
Max. Individual
20 p
> 20 p
Max. RMS
Max. Individual
Max. Average
Max. Individual
Max. RMS
Min. Individual
Min. RMSMin. Individual
Min. Individual
Min. Individual
150 kHz
1024 kHz
C X C
C X B
12.0 8.0 6.0
26.0 20.4 16.0
2500 3000 3600
10000
147.4 94.0 55.8
2.0 1.5 1.5
5.0 5.0 4.0
46 ~56
48 ~54
45.3
181
574
2625
68
58
5235
53
40
7/31/2019 Caracter i Sticas Cables
7/25
External NetworkDry Core Cable
7
Size Characteristics
Number ofPairs
RatedLength
(m)
Designation
CTP-APL-AS
40
10 20.5 9.5 250
Height
Width
1000
Rated External Diameter(mm)
RatedNet
Mass(kg/km)Heigth Width
20
30
50
75
100
22.0 11.0 265 1000
23.2 12.2 325 1000
25.2 14.2 400 1000
27.2 16.2 490 1000
28.7 17.7 575 1000
CTP-APL-AS
50
10 22.0 11.0 270 1000
20
30
50
75
100
23.2 12.1 325 1000
25.0 14.0 385 1000
27.2 16.2 495 1000
28.7 16.4 640 1000
30.0 21.6 770 1000
CTP-APL-AS
65
10 23.0 12.0 310 1000
20
30
50
25.5 14.5 400 1000
27.5 16.5 495 1000
31.0 20.0 675 1000
7/31/2019 Caracter i Sticas Cables
8/25
CTP-APL-SN
Application:
Made of tinned copper conductors, thiscable provides an excellent performance formechanical connections on terminal blocks,avoiding oxidation of the conductor copper.Its design affords total protection from bad
weather. Indicated as transition cables stubs,for use in distribution closets, terminal boxesand building entrances.
Description:
Telephone cable consisting of solid tinnedcopper conductors. Expanded thermoplasticinsulation coated with a thin layer of solidthermoplastic, grouped in pairs, coreprotected by an APL sheath. Specification:
ABNT NBR 10488 and Telebrs 235.320.713ANATEL Certification 46598-XXX256
8
Electrical Characteristics
Conductor Diameter (mm) 0.50
Maximum Electrical Resistance (/km)
Resistive Unbalance (%)
MutualCapacitance (nF/km)
Average
CapacitanceUnbalance (pF/km)
P x P
P x T
Far EndCrosstalk Leak (dB/km)
150kHz
1024kHz
Max. Average
Max. Individual
20 p
> 20 p
Max. RMS
Max. Individual
Max. Average
Max. Individual
Min. RMS
Min. Individual
Min. RMS
Min. Individual
C X C
C X B
46 ~56
48 ~54
45.3
181
574
2625
68
58
52
35
Overall Features
Specifications ValueConductor Tinned Copper
Conductor Diameter (mm) 0.50
Number of Pairs 10 to 600
Insulation Polyethylene or Polypropilene
Cladding Non-moisture Absorbing Tape(s)
External Sheath APL Sheath
* Other conductor diameters and cable composition available on inquiry.
7.0
3.0
97.8
3000
10000Applied Voltage (V )cc
Near EndCrosstalk Leak (dB)
150kHz
1024kHz
Min. Individual
Min. Individual
53
40
7/31/2019 Caracter i Sticas Cables
9/25
External NetworkDry Core Cable
9
Size Characteristics
Number ofPairs
RatedExternalDiameter
(mm)
RatedNet
Mass(kg/km)
RatedLength
(m)
Designation
CTP-APL-SN
50
10 9.4 115 1000
20 10.7 180 1000
30 12.2 240 1000
50 14.2 370 1000
75 16.2 515 1000
100 17.2 665 1000
200 20.9 1250 500
300 23.9 1790 500
400 28.8 2380 500600 31.8 3480 250
7/31/2019 Caracter i Sticas Cables
10/25
CCE-APL
Application:
Made of electrolytic copper conductors,this product allows transmitting analog anddigital and multimedia and lnternet services,among other. Its design affords full protection
from bad weather. Indicated for externalnetworks for branching from distributionsplices to subscriber inputs, can beinstalled in duct lines or overhead lines.
Description:
Telephone cable consisting of solidelectrolytic copper conductors.Thermoplastic insulation, grouped inup to 6 pairs, core protected byan APL sheath.
Specification:ABNT NBR 9124 and Telebrs 235.320.710ANATEL Certification 45698-XXX256
10
Electrical Characteristics
Conductor Diameter (mm) 0.50 0.65
Maximum Electrical Resistance (/km)
Resistive Unbalance (%) Max. Individual
94.0 55.8
Overall Features
Specifications Value
Conductor Bare Copper
Conductor Diameter (mm)0.500.65
Number of Pairs 02 to 06
Insulation Polyethylene or Polypropylene
Cladding Non-moisture Absorbing Tape(s)
External Sheath APL Sheath
* Other conductor diameters and cable composition available on inquiry.
5.0 4.0
46 ~ 56
CapacitanceUnbalance (pF/km)
Max. Individual 2625
Max. Individual 181P x P
P x T
Far EndCrosstalk Leak (dB/km)
Min. Individual 35
Min. Individual 58150kHz
1024kHz
TransmissionAttenuation (dB/km)
150 kHzAverage
1024 kHz
10000
C X C
C X B
8.0 6.0
20.4 16.0
3000 3600Applied Voltage (V )cc
MutualCapacitance (nF/km)
Average
7/31/2019 Caracter i Sticas Cables
11/25
CCE-APL50
External NetworkDry Core Cable
11
Size Characteristics
Number ofPairs
RatedExternalDiameter
(mm)
RatedNet
Mass(kg/km)
RatedLength
(m)
Designation
2 6.6 40 1000
3 7.0 49
4 7.5 54
5 8.3 65
6 8.7 76
CCE-APL65
2 7.5 51 1000
3 8.5 63 1000
4 9.2 77 1000
5 10.0 87 1000
6 10.2 99 1000
1000
1000
1000
1000
7/31/2019 Caracter i Sticas Cables
12/25
CTP-APL-G
Application:
The rigorous technical characteristics of thisproduct allows transmitting analog and digitalsignals at high-rates, such, as ADSL, HDSL,ISDN, etc. Provides a significant improvementin new services, such as multimedia, Internet,
remote conferencing and voice over IP,among other. Its robust construction affordstotal protection from bad weather. The use ofa water sealing compound recommends it forinstallation in high humidity environments,including directly buried in the ground.
Specification:ABNT NBR 9888 and Telebrs 235.320.702ANATEL Certification 46498-XXX256
12
Electrical Characteristics
Conductor Diameter(mm) 0.40 0.50 0.65
Maximum Electrical Resistance (/km)
Resistive Unbalance (%)
MutualCapacitance (nF/km)
Average
CapacitanceUnbalance (pF/km)
P x P
P x T
Far EndCrosstalk Leak (dB/km)
150kHz
Near EndCrosstalk Leak (dB)
1024kHz
150kHz
1024kHz
AverageTransmissionAttenuation (dB/km)
Applied Voltage (V )cc
Max. Average
Max. Individual
20 p
> 20 p
Max. RMS
Max. Individual
Max. Average
Max. Individual
Min. RMS
Min. Individual
Min. RMS
Min. Individual
Min. Individual
Min. Individual
150 kHz
1024 kHz
C X C
C X B
11.2 7.0 5.1
25.1 19.5 15.3
2800 4000 5000
10000
147.2 94.0 55.8
2.0 1.5 1.5
5.0 5.0 4.0
46 ~56
48 ~54
45.3
181
574
2625
68
58
52
35
53
40
Overall Features
Specifications Value
Conductor Bare Copper
Conductor Diameter (mm)0.400.500.65
Number of Pairs 10 to 600
Insulation Polyethylene or Polypropylene
Cladding Non-moisture Absorbing Tape(s)
External Sheath APL Sheath
Description:
Telephone cable consisting of solid electrolyticcopper conductors. Thermoplastic insulation,grouped in pairs, core filled with a water-proofing compoun and protected by
an APL sheath.
* Other conductor diameters and cable composition available on inquiry.
7/31/2019 Caracter i Sticas Cables
13/25
External NetworkGel Core Cable
13
Size Characteristics
Number ofPairs
RatedExternalDiameter
(mm)
RatedNet
Mass(kg/km)
RatedLength
(m)
Designation
CTP-APL-G40
10 11.2 105 2000
20 13.4 159 2000
30 15.2 212 2000
50 17.4 308 2000
75 20.2 425 2000
100 22.4 540 2000
200 29.9 1004 1000
300 35.3 1457 1000
400 39.8 1889 1000600 47.4 2779 1000
CTP-APL-G50
10 12.4 134 2000
20 16.2 220 2000
30 17.2 289 2000
50 20.2 434 2000
75 23.6 617 2000
100 26.4 785 2000
200 30.0 1473 1000
300 41.9 2166 1000400 47.3 2860 1000
600 56.9 4230 500
CTP-APL-G65
10 14.2 186 2000
20 17.7 309 2000
30 20.2 427 2000
50 24.9 687 2000
75 28.8 986 2000
100 32.8 1265 2000
200 44.4 2410 1000300 52.8 3534 1000
400 60.2 4653 400
600 71.8 7200 400
7/31/2019 Caracter i Sticas Cables
14/25
CTS-APL-G
Specification:ABNT NBR 11180 and Telebrs 235.320.714ANATEL Certification 47198-XXX256
14
Electrical Characteristics
Conductor Diameter (mm) 0.40 0,50
Maximum Electrical Resistance (/km)
Resistive Unbalance (%)
MutualCapacitance (nF/km)
Average
CapacitanceUnbalance (pF/km)
P x P
P x T
Far EndCrosstalk Leak (dB/km)
150kHz
Near EndCrosstalk Leak (dB)
1024kHz
150kHz
1024kHz
AverageTransmissionAttenuation (dB/km)
Applied Voltage (V )cc
Max. Average
Max. Individual
20 p
> 20 p
Max. RMS
Max. Individual
Max. Average
Max. Individual
Min. RMS
Min. Individual
Min. RMS
Min. Individual
Min. Individual
Min. Individual
150 kHz
1024 kHz
C X C
C X B
11.2 7.0
25.1 19.5
2400 2000
10000
147.2 94.0
2.0 1.5
5.0 5.0
46 ~56
48 ~54
45.3
181
574
2625
68
58
52
35
53
40
Overall FeaturesSpecifications Value
Conductor Bare Copper
Conductor Diameter (mm)0.400.50
Number of Pairs 10 to 2400
Insulation Foam Skin
Cladding Non-moisture Absorbing Tape(s)
External Sheath APL Sheath
* Other conductor diameters and cable composition available on inquiry.
Application:
The use of Foam Skin insulation results in alighter weight and smaller product ascompared to CTP-APL-G cable. Its enhancedtechnical characteristics allow transmitting analogand digital signals at high-rates invarious applications, such as ADSL, VDSL,ISDN, etc. Provides a better quality in the severalservices it is applied to such as:
multimedia, lnternet, remote conferecingand voice over IP, among other. Its robustconstruction affords total protection from badweather. Indicated for external networks astrunk, primary or secondary cable. The useof a water sealing compound recommendsit for installation in high humidityenvironments, including directlyburied in the ground.
Description:
Telephone cable consisting of solidelectrolytic copper conductors. Expandedthermoplastic insulation coated with a thinlayer of solid thermoplastic, grouped inpairs, core filled with a water-proofingcompound and protected by an APL sheath.
7/31/2019 Caracter i Sticas Cables
15/25
External NetworkGel Core Cable
15
Size Characteristics
Number ofPairs
RatedExternalDiameter
(mm)
RatedNet
Mass(kg/km)
RatedLength
(m)
Designation
CTS-APL-G40
10 10.9 110 2000
20 12.9 150 2000
30 14.5 210 2000
50 16.7 295 2000
75 19.0 408 2000
100 21.1 490 2000
200 25.2 836 2000
300 30.0 1222 2000
400 34.3 1494 1000600 41.5 2332 1000
900 49.5 3445 500
1200 58.3 4563 500
1500 62.0 5614 400
1800 67.1 6635 400
2400 77.0 8500 400
CTS-APL-G50
10 11.6 150 2000
20 13.9 195 2000
30 15.6 280 200050 18.5 405 2000
75 21.3 565 2000
100 23.6 710 2000
200 31.2 1209 1000
300 40.5 1950 1000
400 45.4 2619 1000
600 51.8 2550 400
900 60.2 5300 400
1200 62.1 7245 400
Conductor
Expanded PE(Plastic + Air)
Solid PE
7/31/2019 Caracter i Sticas Cables
16/25
CCE-APL-G
Application:
Made of electrolytic copper conductors,this product allows transmitting analogand digital signal and multimedia andInternet services, among other. Its design
affords total protection from bad weather.Indicated for external networks forbranching from distribution splices tosubscriber inputs. The use of a watersealing compound recommends it forinstallation in high humidity environments,including directly buried in the ground.
Description:
Telephone cable consisting of solidelectrolytic copper conductors.
Thermoplastic insulation, grouped inup to 6 pairs, core filled with water-proofmaterial and protected by an APL sheath.
Specification:
ABNT NBR 9888 and Telebrs 235.320.711ANATEL Certification 45898-XXX256
16
Overall Features
Specifications Value
Conductor Bare Copper
Conductor Diameter (mm)0.500.65
Number of Pairs 02 to 06
Insulation Polyethylene or Polypropylene
Cladding Non-moisture Absorbing Tape(s)
External Sheath APL Sheath
* Other conductor diameters and cable composition available on inquiry.
Electrical Characteristics
Conductor Diameter (mm) 0.50 0.65
Maximum Electrical Resistance (/km)
Resistive Unbalance (%) Max. Individual
94.0 55.8
5.0 4.0
MutualCapacitance (nF/km) Average 46 ~ 56
CapacitanceUnbalance (pF/km)
Max. Individual 2625
Max. Individual 181P x P
P x T
Far EndCrosstalk Leak (dB/km)
Min. Individual 35
Min. Individual 58150kHz
1024kHz
TransmissionAttenuation (dB/km)
150 kHzAverage
1024 kHz
10000
C X C
C X B
7.0 5.1
19.5 15.3
4000 5000Applied Voltage (V )cc
7/31/2019 Caracter i Sticas Cables
17/25
External NetworkGel Core Cable
17
CCE-APL-G50
Size Characteristics
Number ofPairs
RatedExternalDiameter
(mm)
RatedNet
Mass(kg/km)
RatedLength
(m)
Designation
2 7.5 52 1000
3 8.2 62
4 8.8 67
5 9.3 78
6 9.5 89
CCE-APL-G65
2 8.0 69 1000
3 9.1 84 1000
4 10.4 95 1000
5 10.6 110 1000
6 12.0 130 1000
1000
1000
1000
1000
7/31/2019 Caracter i Sticas Cables
18/25
CIT
Application:
Using thermoplastic insulation with excellent,temperature stable electrical characteristics,the product provides an enhanced analogand digital signal transmission performance.Its rigorous technical requirements allow itsapplication to state-of-the-art high rate digitalnetworks, such as: ADSL, HDSL, VDSL,ISDN, etc. Provides s better quality in manyservices, such as multimedia, remote conferecing,lnternet and voice over IP,among other. Its fire-stopping characteristicsindicates it for use in internal installations in centraltelephone offices, commercial,industrial and residential buildings orapplication which require fire-stopping safetyprovisions and electrical characteristics thatmeet the needs of state-of-the-art highspeed transmission networks.
Description:
Telephone cable consisting of solid tinnedelectrolytic copper conductors. Fire-stoppingthermoplastic insulation, grouped in pairs,core coated in a layer of PVC.
Specification:ABNT NBR 10501 and Furukawa PT-803ANATEL Certification 46098-XXX256
18
Electrical Characteristics
Conductor Diameter (mm) 0.40 0.50 0.60
Maximum Electrical Resistance (/km)
ResistiveUnbalance (%)
MutualCapacitance (nF/km)
TransmissionAttenuation (dB/km)
Max. Average
Max. Individual
150 kHzAverage
C X C
C X B
153.0 97.8 67.9
80
1500
2800
Overall Features
Specifications Value
Conductor Tinned Copper
Conductor Diameter (mm)0.400.500.65
Number of Pairs 10 to 1200
Insulation
Cladding
Fire-stopping
External Sheath Gray PVC
Non-moisture Absorbing Tape(s)
* Other conductor diameters and cable composition available on inquiry.
7.0
3.0
Maximum Average
1024 kHz
10.1 8.6 7.1
29.3 26.0 21.6
Applied Voltage (V )cc
Fully Shilded Aluminum or Aluminized Polyester Tapesand Continuity Wire(s)
7/31/2019 Caracter i Sticas Cables
19/25
Internal Network
19
Size Characteristics
Number ofPairs
RatedExternal
Diameter(mm)
RatedNet
Mass(kg/km)
RatedLength
(m)
Designation
CIT40
10 7.6 55 1000
15 8.6 72 100020 9.6 96 100025 10.6 113 100030 11.1 130 100040 12.6 164 100050 13.6 200 100075 15.6 281 1000100 18.1 375 1000200 24.1 687 500300 29.6 1012 500400 33.6 1314 500
600 40.1 1942 250800 46.1 2537 250900 48.6 2873 250
1200 55.1 3759 250
CIT
50
10 8.6 72 1000
15 9.1 95 100020 10.6 128 100025 11.6 152 100030 12.6 176 100040 13.6 224 100050 15.1 276 100075 18.1 408 1000100 20.1 523 1000200 27.6 1000 500300 33.1 1446 500400 37.6 1918 500600 45.6 2800 250800 52.1 3710 250900 54.6 4155 250
1200 62.1 5459 250
CIT60
10 9.1 91 1000
15 10.1 124 100020 11.6 165 100025 12.6 198 100030 13.6 232 1000
40 15.1 297 100050 16.6 368 100075 19.6 543 500100 22.1 702 500200 31.1 1450 500300 36.6 2084 250400 41.6 2746 250600 50.1 3997 250
7/31/2019 Caracter i Sticas Cables
20/25
8
CablesForms
20
CABLES: CTP-APL CTS-APL CTP-APL-AS CTP-APL-SN
CCE-APL CTP-APL-G CTS-APL-G CCE-APL-G
*
CONCENTRIC FORMS
* Pilot Pair, when used.Note: The indicated color code refers to group bundling.Extra pair cables with more than 400 pairs: extra pairs are placed in the group or supergroup interstices of the external corona.The quantity and color code for extra pairs are according to the table of page 24.
2
13
*20 Pairs
6
1
16
*30 Pairs
10
4
9
BASIC GROUPS FOR MULTIPLE FORMS
12 Pairs
3
9
13 Pairs
4
13
25 Pairs
9
3
MULTIPLE FORMS
50 Pairs
W-B12
75 Pairs 100 Pairs
W-B13
W-O13
*
W-O12
W-G25
*
W-B25
W-O25
W-Br25
*
W-B25
W-G25
W-O25
C-G25
*
W-G25
200 Pairs 300 Pairs 400 Pairs
600 Pairs 900 Pairs 1200 Pairs
1500 Pairs 1800 Pairs 2400 Pairs
W-B25
W-O25
C-B25
W-Br25
*
C-O25
W-Gr25
C-Gr25
C-Br25
Bk-B25
W-Gr25
G-O25
C-B25
W-G25
W-O25
C-O25
C-Br25
C-Gr25
Bk-B25
Bk-G25
Bk-Br25
C-B25
W-O25
W-Gr25
W-O25
10 Pairs
V-Br100* Bk-G
100*
Bk-O100* W-Gr
100*V-G100
* Bk-Br100*
V-O100* Bk-Gr
100*
V-B100* Y-B
100*
Y-O100*
Y-Br
100
* Y-G100
*
Y-Gr100*
C-Br100* C-G
100*
Bk-B100*
C-Gr100*
C-B100*
C-O100*
W-Br100
* W-B100
*
W-G100* W-O
100*
Y-G100*
Y-O100*
Bk-Gr100*
Bk-Br100*
Y-B100*
C-G100*
Bk-O100*
C-O100* W-O
100*
C-Br100*
C-Gr100*
Bk-B100*
C-B100
*
* W-Br100*W-Gr
100
W-G100*W-B
100*
Bk-G100
*
Bk-Gr100
Bk-Br100
Bk-G100
Bk-O100
Bk-B100
C-Gr100
C-Br100
C-G100
C-O100
C-B100
W-O100
W-Gr100
W-G100
W-Br100
W-B100
Bk-O100
* W-Br100
*
W-Gr100
* W-B100
*
W-O100*
Bk-B100
*
C-Gr
100
*
C-G100
*
W-Gr100
*
C-O100
*
C-B
100
*
C-Br100
*
*
C-Gr100
*
C-O100
*
C-B100
*
W-Gr100
*
W-B100
*W-Br100
*
W-G100
*
W-O100
*
V-Br25
*
V-G25
V-O25
V-B
25
Y-Gr25
*Y-Br25
Y-G25
Y-O25
Y-B
25
*
Bk-Gr25
Bk-Br25
Bk-G25
Bk-O25
* W-Gr25
C-Br25
C-G25
C-Gr
25
C-O
25
*
Bk-B25
C-B25W-Br25
* W-B25
W-G25
W-O25
Y-B25*
C-Gr25 *
W-Br25 *
Br-Gr25
W-O25
Bk-O25 *
C-G25
*
W-Br25
* W-B25
Bk-O25
*
C-Br100
*
*
*
**
*
*
*
*
* *
* *
*
*
*
7/31/2019 Caracter i Sticas Cables
21/25
21
CablesForms
8
CABLE CIT
*
CONCENTRIC FORMS
* Pilot Pair, when used.Note: The indicated color code refers to group bundling.Extra pair cables with more than 400 pairs: extra pairs are placed in the group or supergroup interstices of the external corona.
The quantity and color code for extra pairs are according to the table of page 24.
2
10 Pairs
6
*
1
20 Pairs
1310
*
4
30 Pairs
16
3
12 Pairs
BASIC GROUPS FOR MULTIPLE FORMS
9
4
13 Pairs
9
3
25 Pairs
9
13
W-B12
MULTIPLE FORMS
W-O13
*
W-B13
W-O12
W-G25
*
W-O25
W-B25
W-Br25
*
W-G25
W-B25
W-O25
Bk-Br25
BK-G25
Bk-B25
C-B25
W-Gr25
C-O25
C-Br25
C-Gr25
W-O25
W-G25
W-B25
W-Gr25
C-B25
C-O25
C-Gr25
W-G25
C-Br25
Bk-B25 W-B
25
W-O25
W-B25
W-O25
C-G25
*C-O25
W-G25
W-Br25
*W-Gr
25
C-B25
V-G25
V-O25
V-B25
Y-G25
Y-Br25
Bk-B25
C-Br25
C-Gr25
W-Gr25
W-G25
W-B25
W-O25
C-B25
C-O25
Bk-G25
Bk-Br25
Bk-Gr25
Y-O25
*Bk-O25
*C-G25
*W-Br25
*Y-B25
*
*W-Br25
Bk-Gr25
*C-G25
50 Pairs 75 Pairs 100 Pairs
200 Pairs 300 Pairs 400 Pairs
600 Pairs 900 Pairs 1200 Pairs
Bk-O25
*V-Br25
*C-G25
*Y-B25
*Y-Gr25
*Bk-O25
*W-Br25
*C-Br100
*W-G100
*W-Br100
*W-Gr100
*C-B100
*C-G100
*C-O100
*W-B100
*W-O100
*W-G100
*W-O100
*W-B100
*Bk-O100
*Bk-Br100
*Bk-B
100
*W-Gr
100
*C-Gr100
*C-B100
*C-O100
*C-Br100 *
C-G100
7/31/2019 Caracter i Sticas Cables
22/25
CorrectionFactors
22
I) Capacitance Unbalance ( C)
A) Pair-Pair
Thermoplastic Insulated CablesFor a component , in meters, different from 1000 m, the limits of capacitance unbalance ( C) aregiven by the following formula:
l
- maximum rms
( C)
( )l= 45,3 .
1000l (pF)
- maximum individual
( C)
( )l= 181 .
1000l (pF)
- maximum average
( C)
(
)l
= 574 .
1000
l (pF)
- maximum individual
( C)
( )l= 2645 .
1000l (pF)
- ratio mean square
150 kHz
RT( )l
= 68 + 10 logl
1000 (dB)
1024 kHz
RT = 52+ 10 logl
1000
- minimum individual
150 kHz
RT( )l
= 58 + 10 logl
1000 (dB)
1024 kHz
RT = 35+ 10 logl
1000
II) Far End Crosstalk Leak (RT)
For a component , in meters, different from 100 m, the FEX leak (RT) is given by the following
formula:
l
B) Pair-Ground
Thermoplastic Insulated CablesFor a component , in meters, different from 1000 m, the limits of capacitance unbalance ( C) aregiven by the following formula:
l
7/31/2019 Caracter i Sticas Cables
23/25
23
ColorCode
Cables: CTP-APL CTS-APL CTS-APL-G
Number ofSupergroup
W: White, B: Blue, O: Orange, G: Green. Br: Brown, Gr: Gray, C: Crimson, Bk: Black, Y: Yellow, V: Violet
1
Color of Binding ofSupergroup
W-B
Sequence of Pairs in Supergroup
1 to 50 1 to 100
50 100
2 W-O 51 to 100 101 to 200
3 W-G 101 to 150 201 to 300
4 W-Br 151 to 200 301 to 400
5 W-Gr 201 to 250 401 to 500
6 C-B 251 to 300 501 to 600
7 C-O 301 to 350 601 to 700
8 C-G 351 to 400 701 to 800
9 C-Br 401 to 450 801 to 900
10 C-Gr 451 to 500 901 to 1000
11 Bk-B 501 to 550 1001 to 1100
12 Bk-Y 551 to 600 1101 to 1200
13 Bk-G 601 to 650 1201 to 1300
14 Bk-Br 651 to 700 1301 to 1400
15 Bk-Gr 701 to 750 1401 to 1500
16 Y-B 751 to 800 1501 to 1600
17 Y-O 801 to 850 1601 to 1700
18 Y-G 851 to 900 1701 to 1800
19 Y-Br - 1801 to 1900
20 Y-Gr - 1901 to 2000
21 V-B - 2001 to 2100
22 V-O - 2101 to 2200
23 V-G - 2201 to 2300
24 V-Br - 2301 to 2400
Cables: CTP-APL CTP-APL-G CTP-APL-AS
CCE-APL CCE-APL-G CIT
Pair Color
W-B1
Pair Color
C-Bl6
Pair Color
Bk-B11
Pair Color
Y-B16
Pair Color
V-B21
W-O2 C-O7 Bk-O12 Y-O17 V-O22
W-G3 C-G8 Bk-V13 Y-G18 V-G23
W-Br4 C-Br9 Bk-Br14 Y-Br19 V-Br24
W-Gr5 C-Gr10 Bk-Gr15 Y-Gr20 V-Gr25
W: White, B: Blue, O: Orange, G: Green. Br: Brown, Gr: Gray, C: Crimson, Bk: Black, Y: Yellow, V: Violet
7/31/2019 Caracter i Sticas Cables
24/25
ColorCode
24
Identification of Extra Pairs
Extra Pair
1
Number Color Code
Colors
A Vein B Vein
2
3
4
5
6
7
89
10
11
12
W-C White Crimson
W-Y White Yellow
W-V White Violet
C-Bk Crimson Black
C-Y Crimson Yellow
C-V Crimson Violet
Bk-Y Black Yellow
Bk-V Black VioletY-V Yellow Violet
B-O Blue Orange
B-G Blue Green
B-Br Blue Brown
Quantity of Pilot Pairs
(when used) and Extra Pairs
Numberof Rated
Pairs
10
Numberof PilotPairs
1
Numberof Extra
Pairs
-
20 1 -
30 1 -
50 1 -
75 1 -
100 1 -
200 2 -
300 3 -
400 4 -
600 6 2
900 9 2
1200 12 3
1500 15 4
1800 18 5
2400 24 6
7/31/2019 Caracter i Sticas Cables
25/25
OthersProducts
Furukawa provides other Outdoor Network products, such as corrugated steel tape armored cablesfor underground deployment in ducts or directly buried in the ground (CTP-APL-G-AR), fibersupported cables (CCE-APL-ASF) or cables for indoor network (CI).
Armored Cable CCE-APL-ASF Cable
CI Cable