Caracter i Sticas Cables

Embed Size (px)

Citation preview

  • 7/31/2019 Caracter i Sticas Cables

    1/25

    INDEX

    External Network

    Dry Core Cables

    CTP-APL ........................................................................................................................................... CTS-APL ........................................................................................................................................... CTP-APL-AS ..................................................................................................................................... CTP-APL-SN ..................................................................................................................................... CCE-APL ...........................................................................................................................................

    2 e 34 e 56 e 78 e 9

    10 e 11

    Gel Core Cable

    CTP-APL-G ........................................................................................................................................ CTS-APL-G ............................................................................................................................................

    CCE-APL-G ........................................................................................................................................

    12 e 1314 e 15

    16 e17

    Internal Network

    CIT ..................... ..................... ...................... ..................... ...................... ............................... .............. 18 e 19

    Cable Forms .............................................................................................................................

    Correction Factors.............................................................................................................Color Code ..................................................................................................................................

    Others Products ....................................................................................................................

    20 e 21

    22

    23 e 24

    25

    1

    www.furukawa.com.br

    URUKAF WABUILDING THE NETWORKS OF THE FUTURE

  • 7/31/2019 Caracter i Sticas Cables

    2/25

    CTP-APL

    Specification:ABNT NBR 9124 and Telebrs 235.320.701ANATEL Certification 46298-XXX-256

    2

    Electrical Characteristics

    Conductor Diameter (mm) 0,40 0,50 0,65

    Maximum Electrical Resistance (/km)

    Resistive Unbalance (%)

    MutualCapacitance (nF/km)

    Average

    CapacitanceUnbalance (pF/km)

    P x P

    P x T

    Far EndCrosstalk Leak (dB/km)

    150kHz

    Near EndCrosstalk Leak (dB)

    1024kHz

    150kHz

    1024kHz

    AverageTransmissionAttenuation (dB/km)

    Applied Voltage (V )cc

    Max. Average

    Max. Individual

    20 p

    > 20 p

    Max. RMS

    Max. Individual

    Max. Average

    Max. Individual

    Max. RMS

    Min. Individual

    Min. RMS

    Min. Individual

    Min. Individual

    Min. Individual

    150 kHz

    1024 kHz

    C X C

    C X B

    12.0 8.0 6.0

    26.0 20.4 16.0

    2500 3000 3600

    10000

    147.2 94.0 55.8

    2.0 1.5 1.5

    5.0 5.0 4.0

    46 ~56

    48 ~54

    45.3

    181

    574

    2625

    68

    58

    52

    35

    53

    40

    Overall Features

    Specifications Value

    Conductor Bare Copper

    Conductor Diameter (mm)0.400.500.65

    Number of Pairs 10 to 2400

    Insulation Polyethylene or Polypropylene

    Cladding Non-moisture Absorbing Tape(s)

    External Sheath APL Sheath

    * Other conductor diameters and cable composition available on inquiry.

    Application:

    The rigorous technical characteristics ofthis product allows transmitting analogand digital signals via high-ratestate-of-the-art transmission technologiessuch as ADSL, HDSL, VDSL, ISDN, etc.Provides a significant improvement in newservices, such as: multimedia, Internet,remote conferencing and voice over IP,among other. Its robust construction affordstotal protection from bad weather. Indicatedfor external networks as trunk, primary orsecondary cable, and can be installed inducts lines or overhead lines.

    Description:

    Telephone cable consisting of solidelectrolytic copper conductors.Thermoplastic insulation, grouped in pairs,core protected by an APL sheath.

  • 7/31/2019 Caracter i Sticas Cables

    3/25

    External NetworkDry Core Cable

    3

    CTP-APL40

    10 9.4 79 2000

    20 10.7 114 2000

    30 12.2 154 2000

    50 14.2 223 2000

    75 16.2 303 2000

    100 17.2 378 2000

    200 23.9 698 2000

    300 28.8 1021 2000

    400 31.8 1336 1000600 38.1 1965 1000

    900 44.9 2850 500

    1200 50.9 3739 500

    1500 56.6 4623 400

    1800 62.0 5004 400

    2400 69.9 7274 400

    CTP-APL50

    10 10.7 101 2000

    20 11.7 153 2000

    30 13.9 212 200050 16.4 350 2000

    75 19.1 400 2000

    100 21.6 620 2000

    200 28.8 1150 1000

    300 34.6 1160 1000

    400 38.6 2170 1000

    600 46.1 2972 500

    900 55.3 4359 400

    1200 63.0 5765 400

    1500 69.9 7159 400

    CTP-APL65

    10 11.7 150 2000

    20 14.0 239 2000

    30 16.1 324 2000

    50 20.1 490 2000

    75 23.6 739 2000

    100 26.7 947 2000

    200 36.9 1775 1000

    300 44.1 2577 1000

    400 50.3 3392 400

    600 57.4 5031 400

    900 71.2 7450 400

    Size Characteristics

    Number ofPairs

    RatedExternalDiameter

    (mm)

    RatedNet Mass(kg/km)

    RatedLength

    (m)

    Designation

  • 7/31/2019 Caracter i Sticas Cables

    4/25

    CTS-APL

    Application:

    The use of Foam Skin insulation results ina lighter weight and more compact productas compared to CTP-APL cable. Allowstransmitting analog and digital signals via

    high-rate-state-of-the-art transmissiontecnologies such as ADSL, HDSL, VDSL,ISDN, etc. Provides a significantimprovement in new services, such as:multimedia, lnternet, remote conferencingand voice over IP, among other. Its robustconstruction affords total protection frombad weather. Indicated for external networks,such as trunck, primary or secondary cable,and can be installed in ducted lines oroverhead lines.

    Description:

    Telephone cable consisting of solidelectrolytic copper conductors. Expandedthermoplastic insulation coated with a thinlayer of solid thermoplastic, grouped in pairs,core protected by an APL Sheath.

    Specification:Telebrs 235.320.714, Furukawa PT 0480ANATEL Certification 47098-XXX256

    4

    Electrical Characteristics

    Conductor Diameter (mm) 0.40 0.50

    Maximum Electrical Resistance (/km)

    Resistive Unbalance(%)

    MutualCapacitance (nF/km)

    Average

    Far EndCrosstalk Leak (dB/km)

    P x P

    P x T

    Near EndCrosstalk Leak (dB)

    150kHz

    TransmissionAttenuation (dB/km)

    1024kHz

    150kHz

    1024kHz

    Average

    Applied Voltage (V )cc

    Max. Average

    Max. Individual

    20 p

    > 20 p

    Max. RMS

    Max. Average

    Max. Individual

    Min. RMS

    Min. Individual

    Min. RMS

    Min. Individual

    Min. Individual

    Min. Individual

    150 kHz

    1024 kHz

    C X C

    C X B

    12.0 8.0

    26.0 20.4

    1700 2000

    10000

    147.2 94.0

    1.5

    5.0

    46 ~56

    48 ~54

    45.3

    181

    574

    2625

    68

    58

    52

    53

    40

    Overall Features

    Specifications Value

    Conductor Bare Copper

    Conductor Diameter (mm)0.400.50

    Number of Pairs 10 to 2400

    Insulation Foam Skin

    Cladding Non-moisture Absorbing Tape(s)

    External Sheath APL Sheath

    * Other conductor diameters and cable composition available on inquiry.

    2.0

    CapacitanceUnbalance (pF/km)

    Min. Individual

    35

  • 7/31/2019 Caracter i Sticas Cables

    5/25

    External NetworkDry Core Cable

    5

    Size Characteristics

    Number ofPairs

    RatedExternalDiameter

    (mm)

    RatedNet Mass(kg/km)

    RatedLength

    (m)

    Designation

    CTS-APL40

    10 9.4 70 2000

    20 10.7 111 2000

    30 12.0 143 2000

    50 13.5 213 2000

    75 15.8 294 2000

    100 17.4 372 2000

    200 23.1 684 2000

    300 27.8 1003 2000

    400 30.8 1296 1000600 36.6 1904 1000

    900 44.5 2827 500

    1200 50.2 3682 500

    1500 55.8 4563 400

    1800 60.4 5366 400

    2400 69.0 7146 400

    CTS-APL50

    10 10.5 88 2000

    20 11.4 140 2000

    30 13.5 189 200050 15.8 285 2000

    75 18.0 406 2000

    100 20.4 519 2000

    200 27.3 958 1000

    300 32.6 1400 1000

    400 38.4 1809 1000

    600 43.3 2642 400

    900 53.8 3902 400

    1200 61.3 5129 400

    Conductor

    Expanded PE(Plastic + Air)

    Solid PE

  • 7/31/2019 Caracter i Sticas Cables

    6/25

    CTP-APL-AS

    Application:

    The technical characteristics of this productallow transmitting analog and digital signalsvia high-rate-state-of-the-art transmission

    technologies such as ADSL, HDSL, ISDN, etc.Provides a significant improvement in newservices, such as: multimedia, lnternet, remoteconferencing and voice over IP, among other.Its robust construction affords total protectionfrom bad weather. Indicated for externalnetworks as secondary cable, and can beinstalled in ducts or overhead lines.

    Description:

    Telephone cable consisting of solid electrolyticcopper conductors. Thermoplastic insulation,

    grouped in pairs, core protected by a APLsheath. Supported by thermoplastic-coatedsteel cordage, fitted in parallel with theAPL sheath. Specification:

    ABNT NBR 9889 and Telebrs 235.320.704ANATEL Certification 46398-XXX256

    6

    Overall Features

    Specifications Value

    Conductor Bare Copper

    Conductor Diameter (mm)0.400.500.65

    Number of Pairs 10 to 100

    Insulation Polyethylene or Polypropylene

    Cladding Non-moisture Absorbing Tape(s)

    External Sheath APL Sheath

    * Other conductor diameters and cable composition available on inquiry.

    Electrical Characteristics

    Conductor Diameter (mm) 0.40 0.50 0.65

    Maximum Electrical Resistance (/km)

    Resistive Unbalance (%)

    MutualCapacitance (nF/km)

    Average

    CapacitanceUnbalance (pF/km)

    P x P

    P x T

    Far EndCrosstalk Leak (dB/km)

    150kHz

    Near EndCrosstalk Leak (dB)

    1024kHz

    150kHz

    1024kHz

    AverageTransmissionAttenuation (dB/km)

    Applied Voltage (V )cc

    Max. Average

    Max. Individual

    20 p

    > 20 p

    Max. RMS

    Max. Individual

    Max. Average

    Max. Individual

    Max. RMS

    Min. Individual

    Min. RMSMin. Individual

    Min. Individual

    Min. Individual

    150 kHz

    1024 kHz

    C X C

    C X B

    12.0 8.0 6.0

    26.0 20.4 16.0

    2500 3000 3600

    10000

    147.4 94.0 55.8

    2.0 1.5 1.5

    5.0 5.0 4.0

    46 ~56

    48 ~54

    45.3

    181

    574

    2625

    68

    58

    5235

    53

    40

  • 7/31/2019 Caracter i Sticas Cables

    7/25

    External NetworkDry Core Cable

    7

    Size Characteristics

    Number ofPairs

    RatedLength

    (m)

    Designation

    CTP-APL-AS

    40

    10 20.5 9.5 250

    Height

    Width

    1000

    Rated External Diameter(mm)

    RatedNet

    Mass(kg/km)Heigth Width

    20

    30

    50

    75

    100

    22.0 11.0 265 1000

    23.2 12.2 325 1000

    25.2 14.2 400 1000

    27.2 16.2 490 1000

    28.7 17.7 575 1000

    CTP-APL-AS

    50

    10 22.0 11.0 270 1000

    20

    30

    50

    75

    100

    23.2 12.1 325 1000

    25.0 14.0 385 1000

    27.2 16.2 495 1000

    28.7 16.4 640 1000

    30.0 21.6 770 1000

    CTP-APL-AS

    65

    10 23.0 12.0 310 1000

    20

    30

    50

    25.5 14.5 400 1000

    27.5 16.5 495 1000

    31.0 20.0 675 1000

  • 7/31/2019 Caracter i Sticas Cables

    8/25

    CTP-APL-SN

    Application:

    Made of tinned copper conductors, thiscable provides an excellent performance formechanical connections on terminal blocks,avoiding oxidation of the conductor copper.Its design affords total protection from bad

    weather. Indicated as transition cables stubs,for use in distribution closets, terminal boxesand building entrances.

    Description:

    Telephone cable consisting of solid tinnedcopper conductors. Expanded thermoplasticinsulation coated with a thin layer of solidthermoplastic, grouped in pairs, coreprotected by an APL sheath. Specification:

    ABNT NBR 10488 and Telebrs 235.320.713ANATEL Certification 46598-XXX256

    8

    Electrical Characteristics

    Conductor Diameter (mm) 0.50

    Maximum Electrical Resistance (/km)

    Resistive Unbalance (%)

    MutualCapacitance (nF/km)

    Average

    CapacitanceUnbalance (pF/km)

    P x P

    P x T

    Far EndCrosstalk Leak (dB/km)

    150kHz

    1024kHz

    Max. Average

    Max. Individual

    20 p

    > 20 p

    Max. RMS

    Max. Individual

    Max. Average

    Max. Individual

    Min. RMS

    Min. Individual

    Min. RMS

    Min. Individual

    C X C

    C X B

    46 ~56

    48 ~54

    45.3

    181

    574

    2625

    68

    58

    52

    35

    Overall Features

    Specifications ValueConductor Tinned Copper

    Conductor Diameter (mm) 0.50

    Number of Pairs 10 to 600

    Insulation Polyethylene or Polypropilene

    Cladding Non-moisture Absorbing Tape(s)

    External Sheath APL Sheath

    * Other conductor diameters and cable composition available on inquiry.

    7.0

    3.0

    97.8

    3000

    10000Applied Voltage (V )cc

    Near EndCrosstalk Leak (dB)

    150kHz

    1024kHz

    Min. Individual

    Min. Individual

    53

    40

  • 7/31/2019 Caracter i Sticas Cables

    9/25

    External NetworkDry Core Cable

    9

    Size Characteristics

    Number ofPairs

    RatedExternalDiameter

    (mm)

    RatedNet

    Mass(kg/km)

    RatedLength

    (m)

    Designation

    CTP-APL-SN

    50

    10 9.4 115 1000

    20 10.7 180 1000

    30 12.2 240 1000

    50 14.2 370 1000

    75 16.2 515 1000

    100 17.2 665 1000

    200 20.9 1250 500

    300 23.9 1790 500

    400 28.8 2380 500600 31.8 3480 250

  • 7/31/2019 Caracter i Sticas Cables

    10/25

    CCE-APL

    Application:

    Made of electrolytic copper conductors,this product allows transmitting analog anddigital and multimedia and lnternet services,among other. Its design affords full protection

    from bad weather. Indicated for externalnetworks for branching from distributionsplices to subscriber inputs, can beinstalled in duct lines or overhead lines.

    Description:

    Telephone cable consisting of solidelectrolytic copper conductors.Thermoplastic insulation, grouped inup to 6 pairs, core protected byan APL sheath.

    Specification:ABNT NBR 9124 and Telebrs 235.320.710ANATEL Certification 45698-XXX256

    10

    Electrical Characteristics

    Conductor Diameter (mm) 0.50 0.65

    Maximum Electrical Resistance (/km)

    Resistive Unbalance (%) Max. Individual

    94.0 55.8

    Overall Features

    Specifications Value

    Conductor Bare Copper

    Conductor Diameter (mm)0.500.65

    Number of Pairs 02 to 06

    Insulation Polyethylene or Polypropylene

    Cladding Non-moisture Absorbing Tape(s)

    External Sheath APL Sheath

    * Other conductor diameters and cable composition available on inquiry.

    5.0 4.0

    46 ~ 56

    CapacitanceUnbalance (pF/km)

    Max. Individual 2625

    Max. Individual 181P x P

    P x T

    Far EndCrosstalk Leak (dB/km)

    Min. Individual 35

    Min. Individual 58150kHz

    1024kHz

    TransmissionAttenuation (dB/km)

    150 kHzAverage

    1024 kHz

    10000

    C X C

    C X B

    8.0 6.0

    20.4 16.0

    3000 3600Applied Voltage (V )cc

    MutualCapacitance (nF/km)

    Average

  • 7/31/2019 Caracter i Sticas Cables

    11/25

    CCE-APL50

    External NetworkDry Core Cable

    11

    Size Characteristics

    Number ofPairs

    RatedExternalDiameter

    (mm)

    RatedNet

    Mass(kg/km)

    RatedLength

    (m)

    Designation

    2 6.6 40 1000

    3 7.0 49

    4 7.5 54

    5 8.3 65

    6 8.7 76

    CCE-APL65

    2 7.5 51 1000

    3 8.5 63 1000

    4 9.2 77 1000

    5 10.0 87 1000

    6 10.2 99 1000

    1000

    1000

    1000

    1000

  • 7/31/2019 Caracter i Sticas Cables

    12/25

    CTP-APL-G

    Application:

    The rigorous technical characteristics of thisproduct allows transmitting analog and digitalsignals at high-rates, such, as ADSL, HDSL,ISDN, etc. Provides a significant improvementin new services, such as multimedia, Internet,

    remote conferencing and voice over IP,among other. Its robust construction affordstotal protection from bad weather. The use ofa water sealing compound recommends it forinstallation in high humidity environments,including directly buried in the ground.

    Specification:ABNT NBR 9888 and Telebrs 235.320.702ANATEL Certification 46498-XXX256

    12

    Electrical Characteristics

    Conductor Diameter(mm) 0.40 0.50 0.65

    Maximum Electrical Resistance (/km)

    Resistive Unbalance (%)

    MutualCapacitance (nF/km)

    Average

    CapacitanceUnbalance (pF/km)

    P x P

    P x T

    Far EndCrosstalk Leak (dB/km)

    150kHz

    Near EndCrosstalk Leak (dB)

    1024kHz

    150kHz

    1024kHz

    AverageTransmissionAttenuation (dB/km)

    Applied Voltage (V )cc

    Max. Average

    Max. Individual

    20 p

    > 20 p

    Max. RMS

    Max. Individual

    Max. Average

    Max. Individual

    Min. RMS

    Min. Individual

    Min. RMS

    Min. Individual

    Min. Individual

    Min. Individual

    150 kHz

    1024 kHz

    C X C

    C X B

    11.2 7.0 5.1

    25.1 19.5 15.3

    2800 4000 5000

    10000

    147.2 94.0 55.8

    2.0 1.5 1.5

    5.0 5.0 4.0

    46 ~56

    48 ~54

    45.3

    181

    574

    2625

    68

    58

    52

    35

    53

    40

    Overall Features

    Specifications Value

    Conductor Bare Copper

    Conductor Diameter (mm)0.400.500.65

    Number of Pairs 10 to 600

    Insulation Polyethylene or Polypropylene

    Cladding Non-moisture Absorbing Tape(s)

    External Sheath APL Sheath

    Description:

    Telephone cable consisting of solid electrolyticcopper conductors. Thermoplastic insulation,grouped in pairs, core filled with a water-proofing compoun and protected by

    an APL sheath.

    * Other conductor diameters and cable composition available on inquiry.

  • 7/31/2019 Caracter i Sticas Cables

    13/25

    External NetworkGel Core Cable

    13

    Size Characteristics

    Number ofPairs

    RatedExternalDiameter

    (mm)

    RatedNet

    Mass(kg/km)

    RatedLength

    (m)

    Designation

    CTP-APL-G40

    10 11.2 105 2000

    20 13.4 159 2000

    30 15.2 212 2000

    50 17.4 308 2000

    75 20.2 425 2000

    100 22.4 540 2000

    200 29.9 1004 1000

    300 35.3 1457 1000

    400 39.8 1889 1000600 47.4 2779 1000

    CTP-APL-G50

    10 12.4 134 2000

    20 16.2 220 2000

    30 17.2 289 2000

    50 20.2 434 2000

    75 23.6 617 2000

    100 26.4 785 2000

    200 30.0 1473 1000

    300 41.9 2166 1000400 47.3 2860 1000

    600 56.9 4230 500

    CTP-APL-G65

    10 14.2 186 2000

    20 17.7 309 2000

    30 20.2 427 2000

    50 24.9 687 2000

    75 28.8 986 2000

    100 32.8 1265 2000

    200 44.4 2410 1000300 52.8 3534 1000

    400 60.2 4653 400

    600 71.8 7200 400

  • 7/31/2019 Caracter i Sticas Cables

    14/25

    CTS-APL-G

    Specification:ABNT NBR 11180 and Telebrs 235.320.714ANATEL Certification 47198-XXX256

    14

    Electrical Characteristics

    Conductor Diameter (mm) 0.40 0,50

    Maximum Electrical Resistance (/km)

    Resistive Unbalance (%)

    MutualCapacitance (nF/km)

    Average

    CapacitanceUnbalance (pF/km)

    P x P

    P x T

    Far EndCrosstalk Leak (dB/km)

    150kHz

    Near EndCrosstalk Leak (dB)

    1024kHz

    150kHz

    1024kHz

    AverageTransmissionAttenuation (dB/km)

    Applied Voltage (V )cc

    Max. Average

    Max. Individual

    20 p

    > 20 p

    Max. RMS

    Max. Individual

    Max. Average

    Max. Individual

    Min. RMS

    Min. Individual

    Min. RMS

    Min. Individual

    Min. Individual

    Min. Individual

    150 kHz

    1024 kHz

    C X C

    C X B

    11.2 7.0

    25.1 19.5

    2400 2000

    10000

    147.2 94.0

    2.0 1.5

    5.0 5.0

    46 ~56

    48 ~54

    45.3

    181

    574

    2625

    68

    58

    52

    35

    53

    40

    Overall FeaturesSpecifications Value

    Conductor Bare Copper

    Conductor Diameter (mm)0.400.50

    Number of Pairs 10 to 2400

    Insulation Foam Skin

    Cladding Non-moisture Absorbing Tape(s)

    External Sheath APL Sheath

    * Other conductor diameters and cable composition available on inquiry.

    Application:

    The use of Foam Skin insulation results in alighter weight and smaller product ascompared to CTP-APL-G cable. Its enhancedtechnical characteristics allow transmitting analogand digital signals at high-rates invarious applications, such as ADSL, VDSL,ISDN, etc. Provides a better quality in the severalservices it is applied to such as:

    multimedia, lnternet, remote conferecingand voice over IP, among other. Its robustconstruction affords total protection from badweather. Indicated for external networks astrunk, primary or secondary cable. The useof a water sealing compound recommendsit for installation in high humidityenvironments, including directlyburied in the ground.

    Description:

    Telephone cable consisting of solidelectrolytic copper conductors. Expandedthermoplastic insulation coated with a thinlayer of solid thermoplastic, grouped inpairs, core filled with a water-proofingcompound and protected by an APL sheath.

  • 7/31/2019 Caracter i Sticas Cables

    15/25

    External NetworkGel Core Cable

    15

    Size Characteristics

    Number ofPairs

    RatedExternalDiameter

    (mm)

    RatedNet

    Mass(kg/km)

    RatedLength

    (m)

    Designation

    CTS-APL-G40

    10 10.9 110 2000

    20 12.9 150 2000

    30 14.5 210 2000

    50 16.7 295 2000

    75 19.0 408 2000

    100 21.1 490 2000

    200 25.2 836 2000

    300 30.0 1222 2000

    400 34.3 1494 1000600 41.5 2332 1000

    900 49.5 3445 500

    1200 58.3 4563 500

    1500 62.0 5614 400

    1800 67.1 6635 400

    2400 77.0 8500 400

    CTS-APL-G50

    10 11.6 150 2000

    20 13.9 195 2000

    30 15.6 280 200050 18.5 405 2000

    75 21.3 565 2000

    100 23.6 710 2000

    200 31.2 1209 1000

    300 40.5 1950 1000

    400 45.4 2619 1000

    600 51.8 2550 400

    900 60.2 5300 400

    1200 62.1 7245 400

    Conductor

    Expanded PE(Plastic + Air)

    Solid PE

  • 7/31/2019 Caracter i Sticas Cables

    16/25

    CCE-APL-G

    Application:

    Made of electrolytic copper conductors,this product allows transmitting analogand digital signal and multimedia andInternet services, among other. Its design

    affords total protection from bad weather.Indicated for external networks forbranching from distribution splices tosubscriber inputs. The use of a watersealing compound recommends it forinstallation in high humidity environments,including directly buried in the ground.

    Description:

    Telephone cable consisting of solidelectrolytic copper conductors.

    Thermoplastic insulation, grouped inup to 6 pairs, core filled with water-proofmaterial and protected by an APL sheath.

    Specification:

    ABNT NBR 9888 and Telebrs 235.320.711ANATEL Certification 45898-XXX256

    16

    Overall Features

    Specifications Value

    Conductor Bare Copper

    Conductor Diameter (mm)0.500.65

    Number of Pairs 02 to 06

    Insulation Polyethylene or Polypropylene

    Cladding Non-moisture Absorbing Tape(s)

    External Sheath APL Sheath

    * Other conductor diameters and cable composition available on inquiry.

    Electrical Characteristics

    Conductor Diameter (mm) 0.50 0.65

    Maximum Electrical Resistance (/km)

    Resistive Unbalance (%) Max. Individual

    94.0 55.8

    5.0 4.0

    MutualCapacitance (nF/km) Average 46 ~ 56

    CapacitanceUnbalance (pF/km)

    Max. Individual 2625

    Max. Individual 181P x P

    P x T

    Far EndCrosstalk Leak (dB/km)

    Min. Individual 35

    Min. Individual 58150kHz

    1024kHz

    TransmissionAttenuation (dB/km)

    150 kHzAverage

    1024 kHz

    10000

    C X C

    C X B

    7.0 5.1

    19.5 15.3

    4000 5000Applied Voltage (V )cc

  • 7/31/2019 Caracter i Sticas Cables

    17/25

    External NetworkGel Core Cable

    17

    CCE-APL-G50

    Size Characteristics

    Number ofPairs

    RatedExternalDiameter

    (mm)

    RatedNet

    Mass(kg/km)

    RatedLength

    (m)

    Designation

    2 7.5 52 1000

    3 8.2 62

    4 8.8 67

    5 9.3 78

    6 9.5 89

    CCE-APL-G65

    2 8.0 69 1000

    3 9.1 84 1000

    4 10.4 95 1000

    5 10.6 110 1000

    6 12.0 130 1000

    1000

    1000

    1000

    1000

  • 7/31/2019 Caracter i Sticas Cables

    18/25

    CIT

    Application:

    Using thermoplastic insulation with excellent,temperature stable electrical characteristics,the product provides an enhanced analogand digital signal transmission performance.Its rigorous technical requirements allow itsapplication to state-of-the-art high rate digitalnetworks, such as: ADSL, HDSL, VDSL,ISDN, etc. Provides s better quality in manyservices, such as multimedia, remote conferecing,lnternet and voice over IP,among other. Its fire-stopping characteristicsindicates it for use in internal installations in centraltelephone offices, commercial,industrial and residential buildings orapplication which require fire-stopping safetyprovisions and electrical characteristics thatmeet the needs of state-of-the-art highspeed transmission networks.

    Description:

    Telephone cable consisting of solid tinnedelectrolytic copper conductors. Fire-stoppingthermoplastic insulation, grouped in pairs,core coated in a layer of PVC.

    Specification:ABNT NBR 10501 and Furukawa PT-803ANATEL Certification 46098-XXX256

    18

    Electrical Characteristics

    Conductor Diameter (mm) 0.40 0.50 0.60

    Maximum Electrical Resistance (/km)

    ResistiveUnbalance (%)

    MutualCapacitance (nF/km)

    TransmissionAttenuation (dB/km)

    Max. Average

    Max. Individual

    150 kHzAverage

    C X C

    C X B

    153.0 97.8 67.9

    80

    1500

    2800

    Overall Features

    Specifications Value

    Conductor Tinned Copper

    Conductor Diameter (mm)0.400.500.65

    Number of Pairs 10 to 1200

    Insulation

    Cladding

    Fire-stopping

    External Sheath Gray PVC

    Non-moisture Absorbing Tape(s)

    * Other conductor diameters and cable composition available on inquiry.

    7.0

    3.0

    Maximum Average

    1024 kHz

    10.1 8.6 7.1

    29.3 26.0 21.6

    Applied Voltage (V )cc

    Fully Shilded Aluminum or Aluminized Polyester Tapesand Continuity Wire(s)

  • 7/31/2019 Caracter i Sticas Cables

    19/25

    Internal Network

    19

    Size Characteristics

    Number ofPairs

    RatedExternal

    Diameter(mm)

    RatedNet

    Mass(kg/km)

    RatedLength

    (m)

    Designation

    CIT40

    10 7.6 55 1000

    15 8.6 72 100020 9.6 96 100025 10.6 113 100030 11.1 130 100040 12.6 164 100050 13.6 200 100075 15.6 281 1000100 18.1 375 1000200 24.1 687 500300 29.6 1012 500400 33.6 1314 500

    600 40.1 1942 250800 46.1 2537 250900 48.6 2873 250

    1200 55.1 3759 250

    CIT

    50

    10 8.6 72 1000

    15 9.1 95 100020 10.6 128 100025 11.6 152 100030 12.6 176 100040 13.6 224 100050 15.1 276 100075 18.1 408 1000100 20.1 523 1000200 27.6 1000 500300 33.1 1446 500400 37.6 1918 500600 45.6 2800 250800 52.1 3710 250900 54.6 4155 250

    1200 62.1 5459 250

    CIT60

    10 9.1 91 1000

    15 10.1 124 100020 11.6 165 100025 12.6 198 100030 13.6 232 1000

    40 15.1 297 100050 16.6 368 100075 19.6 543 500100 22.1 702 500200 31.1 1450 500300 36.6 2084 250400 41.6 2746 250600 50.1 3997 250

  • 7/31/2019 Caracter i Sticas Cables

    20/25

    8

    CablesForms

    20

    CABLES: CTP-APL CTS-APL CTP-APL-AS CTP-APL-SN

    CCE-APL CTP-APL-G CTS-APL-G CCE-APL-G

    *

    CONCENTRIC FORMS

    * Pilot Pair, when used.Note: The indicated color code refers to group bundling.Extra pair cables with more than 400 pairs: extra pairs are placed in the group or supergroup interstices of the external corona.The quantity and color code for extra pairs are according to the table of page 24.

    2

    13

    *20 Pairs

    6

    1

    16

    *30 Pairs

    10

    4

    9

    BASIC GROUPS FOR MULTIPLE FORMS

    12 Pairs

    3

    9

    13 Pairs

    4

    13

    25 Pairs

    9

    3

    MULTIPLE FORMS

    50 Pairs

    W-B12

    75 Pairs 100 Pairs

    W-B13

    W-O13

    *

    W-O12

    W-G25

    *

    W-B25

    W-O25

    W-Br25

    *

    W-B25

    W-G25

    W-O25

    C-G25

    *

    W-G25

    200 Pairs 300 Pairs 400 Pairs

    600 Pairs 900 Pairs 1200 Pairs

    1500 Pairs 1800 Pairs 2400 Pairs

    W-B25

    W-O25

    C-B25

    W-Br25

    *

    C-O25

    W-Gr25

    C-Gr25

    C-Br25

    Bk-B25

    W-Gr25

    G-O25

    C-B25

    W-G25

    W-O25

    C-O25

    C-Br25

    C-Gr25

    Bk-B25

    Bk-G25

    Bk-Br25

    C-B25

    W-O25

    W-Gr25

    W-O25

    10 Pairs

    V-Br100* Bk-G

    100*

    Bk-O100* W-Gr

    100*V-G100

    * Bk-Br100*

    V-O100* Bk-Gr

    100*

    V-B100* Y-B

    100*

    Y-O100*

    Y-Br

    100

    * Y-G100

    *

    Y-Gr100*

    C-Br100* C-G

    100*

    Bk-B100*

    C-Gr100*

    C-B100*

    C-O100*

    W-Br100

    * W-B100

    *

    W-G100* W-O

    100*

    Y-G100*

    Y-O100*

    Bk-Gr100*

    Bk-Br100*

    Y-B100*

    C-G100*

    Bk-O100*

    C-O100* W-O

    100*

    C-Br100*

    C-Gr100*

    Bk-B100*

    C-B100

    *

    * W-Br100*W-Gr

    100

    W-G100*W-B

    100*

    Bk-G100

    *

    Bk-Gr100

    Bk-Br100

    Bk-G100

    Bk-O100

    Bk-B100

    C-Gr100

    C-Br100

    C-G100

    C-O100

    C-B100

    W-O100

    W-Gr100

    W-G100

    W-Br100

    W-B100

    Bk-O100

    * W-Br100

    *

    W-Gr100

    * W-B100

    *

    W-O100*

    Bk-B100

    *

    C-Gr

    100

    *

    C-G100

    *

    W-Gr100

    *

    C-O100

    *

    C-B

    100

    *

    C-Br100

    *

    *

    C-Gr100

    *

    C-O100

    *

    C-B100

    *

    W-Gr100

    *

    W-B100

    *W-Br100

    *

    W-G100

    *

    W-O100

    *

    V-Br25

    *

    V-G25

    V-O25

    V-B

    25

    Y-Gr25

    *Y-Br25

    Y-G25

    Y-O25

    Y-B

    25

    *

    Bk-Gr25

    Bk-Br25

    Bk-G25

    Bk-O25

    * W-Gr25

    C-Br25

    C-G25

    C-Gr

    25

    C-O

    25

    *

    Bk-B25

    C-B25W-Br25

    * W-B25

    W-G25

    W-O25

    Y-B25*

    C-Gr25 *

    W-Br25 *

    Br-Gr25

    W-O25

    Bk-O25 *

    C-G25

    *

    W-Br25

    * W-B25

    Bk-O25

    *

    C-Br100

    *

    *

    *

    **

    *

    *

    *

    *

    * *

    * *

    *

    *

    *

  • 7/31/2019 Caracter i Sticas Cables

    21/25

    21

    CablesForms

    8

    CABLE CIT

    *

    CONCENTRIC FORMS

    * Pilot Pair, when used.Note: The indicated color code refers to group bundling.Extra pair cables with more than 400 pairs: extra pairs are placed in the group or supergroup interstices of the external corona.

    The quantity and color code for extra pairs are according to the table of page 24.

    2

    10 Pairs

    6

    *

    1

    20 Pairs

    1310

    *

    4

    30 Pairs

    16

    3

    12 Pairs

    BASIC GROUPS FOR MULTIPLE FORMS

    9

    4

    13 Pairs

    9

    3

    25 Pairs

    9

    13

    W-B12

    MULTIPLE FORMS

    W-O13

    *

    W-B13

    W-O12

    W-G25

    *

    W-O25

    W-B25

    W-Br25

    *

    W-G25

    W-B25

    W-O25

    Bk-Br25

    BK-G25

    Bk-B25

    C-B25

    W-Gr25

    C-O25

    C-Br25

    C-Gr25

    W-O25

    W-G25

    W-B25

    W-Gr25

    C-B25

    C-O25

    C-Gr25

    W-G25

    C-Br25

    Bk-B25 W-B

    25

    W-O25

    W-B25

    W-O25

    C-G25

    *C-O25

    W-G25

    W-Br25

    *W-Gr

    25

    C-B25

    V-G25

    V-O25

    V-B25

    Y-G25

    Y-Br25

    Bk-B25

    C-Br25

    C-Gr25

    W-Gr25

    W-G25

    W-B25

    W-O25

    C-B25

    C-O25

    Bk-G25

    Bk-Br25

    Bk-Gr25

    Y-O25

    *Bk-O25

    *C-G25

    *W-Br25

    *Y-B25

    *

    *W-Br25

    Bk-Gr25

    *C-G25

    50 Pairs 75 Pairs 100 Pairs

    200 Pairs 300 Pairs 400 Pairs

    600 Pairs 900 Pairs 1200 Pairs

    Bk-O25

    *V-Br25

    *C-G25

    *Y-B25

    *Y-Gr25

    *Bk-O25

    *W-Br25

    *C-Br100

    *W-G100

    *W-Br100

    *W-Gr100

    *C-B100

    *C-G100

    *C-O100

    *W-B100

    *W-O100

    *W-G100

    *W-O100

    *W-B100

    *Bk-O100

    *Bk-Br100

    *Bk-B

    100

    *W-Gr

    100

    *C-Gr100

    *C-B100

    *C-O100

    *C-Br100 *

    C-G100

  • 7/31/2019 Caracter i Sticas Cables

    22/25

    CorrectionFactors

    22

    I) Capacitance Unbalance ( C)

    A) Pair-Pair

    Thermoplastic Insulated CablesFor a component , in meters, different from 1000 m, the limits of capacitance unbalance ( C) aregiven by the following formula:

    l

    - maximum rms

    ( C)

    ( )l= 45,3 .

    1000l (pF)

    - maximum individual

    ( C)

    ( )l= 181 .

    1000l (pF)

    - maximum average

    ( C)

    (

    )l

    = 574 .

    1000

    l (pF)

    - maximum individual

    ( C)

    ( )l= 2645 .

    1000l (pF)

    - ratio mean square

    150 kHz

    RT( )l

    = 68 + 10 logl

    1000 (dB)

    1024 kHz

    RT = 52+ 10 logl

    1000

    - minimum individual

    150 kHz

    RT( )l

    = 58 + 10 logl

    1000 (dB)

    1024 kHz

    RT = 35+ 10 logl

    1000

    II) Far End Crosstalk Leak (RT)

    For a component , in meters, different from 100 m, the FEX leak (RT) is given by the following

    formula:

    l

    B) Pair-Ground

    Thermoplastic Insulated CablesFor a component , in meters, different from 1000 m, the limits of capacitance unbalance ( C) aregiven by the following formula:

    l

  • 7/31/2019 Caracter i Sticas Cables

    23/25

    23

    ColorCode

    Cables: CTP-APL CTS-APL CTS-APL-G

    Number ofSupergroup

    W: White, B: Blue, O: Orange, G: Green. Br: Brown, Gr: Gray, C: Crimson, Bk: Black, Y: Yellow, V: Violet

    1

    Color of Binding ofSupergroup

    W-B

    Sequence of Pairs in Supergroup

    1 to 50 1 to 100

    50 100

    2 W-O 51 to 100 101 to 200

    3 W-G 101 to 150 201 to 300

    4 W-Br 151 to 200 301 to 400

    5 W-Gr 201 to 250 401 to 500

    6 C-B 251 to 300 501 to 600

    7 C-O 301 to 350 601 to 700

    8 C-G 351 to 400 701 to 800

    9 C-Br 401 to 450 801 to 900

    10 C-Gr 451 to 500 901 to 1000

    11 Bk-B 501 to 550 1001 to 1100

    12 Bk-Y 551 to 600 1101 to 1200

    13 Bk-G 601 to 650 1201 to 1300

    14 Bk-Br 651 to 700 1301 to 1400

    15 Bk-Gr 701 to 750 1401 to 1500

    16 Y-B 751 to 800 1501 to 1600

    17 Y-O 801 to 850 1601 to 1700

    18 Y-G 851 to 900 1701 to 1800

    19 Y-Br - 1801 to 1900

    20 Y-Gr - 1901 to 2000

    21 V-B - 2001 to 2100

    22 V-O - 2101 to 2200

    23 V-G - 2201 to 2300

    24 V-Br - 2301 to 2400

    Cables: CTP-APL CTP-APL-G CTP-APL-AS

    CCE-APL CCE-APL-G CIT

    Pair Color

    W-B1

    Pair Color

    C-Bl6

    Pair Color

    Bk-B11

    Pair Color

    Y-B16

    Pair Color

    V-B21

    W-O2 C-O7 Bk-O12 Y-O17 V-O22

    W-G3 C-G8 Bk-V13 Y-G18 V-G23

    W-Br4 C-Br9 Bk-Br14 Y-Br19 V-Br24

    W-Gr5 C-Gr10 Bk-Gr15 Y-Gr20 V-Gr25

    W: White, B: Blue, O: Orange, G: Green. Br: Brown, Gr: Gray, C: Crimson, Bk: Black, Y: Yellow, V: Violet

  • 7/31/2019 Caracter i Sticas Cables

    24/25

    ColorCode

    24

    Identification of Extra Pairs

    Extra Pair

    1

    Number Color Code

    Colors

    A Vein B Vein

    2

    3

    4

    5

    6

    7

    89

    10

    11

    12

    W-C White Crimson

    W-Y White Yellow

    W-V White Violet

    C-Bk Crimson Black

    C-Y Crimson Yellow

    C-V Crimson Violet

    Bk-Y Black Yellow

    Bk-V Black VioletY-V Yellow Violet

    B-O Blue Orange

    B-G Blue Green

    B-Br Blue Brown

    Quantity of Pilot Pairs

    (when used) and Extra Pairs

    Numberof Rated

    Pairs

    10

    Numberof PilotPairs

    1

    Numberof Extra

    Pairs

    -

    20 1 -

    30 1 -

    50 1 -

    75 1 -

    100 1 -

    200 2 -

    300 3 -

    400 4 -

    600 6 2

    900 9 2

    1200 12 3

    1500 15 4

    1800 18 5

    2400 24 6

  • 7/31/2019 Caracter i Sticas Cables

    25/25

    OthersProducts

    Furukawa provides other Outdoor Network products, such as corrugated steel tape armored cablesfor underground deployment in ducts or directly buried in the ground (CTP-APL-G-AR), fibersupported cables (CCE-APL-ASF) or cables for indoor network (CI).

    Armored Cable CCE-APL-ASF Cable

    CI Cable