CAPPA ASALAIRBIOHAZARD
ATLANTICAsalair
biohazard hoodAtlantic
1200 – 1500 – 1800
73
BIO
HA
ZA
RD
SA
FETY
CA
BIN
ET
TECHNICAL SPECIFICATIONS• Casing realized in iron plate and steel structurals powdered painted.• Internal chamber in negative pressure to avoid a passage of contaminated air in the work chamber.• Work’s chamber maked in stainless steel AISI 304 with rounded corners to avoid contaminations.• Low box in stainless steel AISI 304 for salvage liquids.• Working surface in stainless steel AISI 304, drill and divided in four parts to facilitate cleanliness
and decontamination.• Frontal membrane key control panel.• Frontal panel in temperated glass with closing gas cylinder and alarm micro switch for open glass.• Closing frontal panel in stainless steel AISI 304 with UV lamp 30 W.• Electronic key for start and germicide lamp.• Power switch and overload fuses.• Electric outlet in work’s chamber. IP 55 protection.• Germicide lamp outlet with timer 0-99 hours.• Air/vacum cock.• Gas cock + safety solenoid valve.• Illumination by fluorescent light external at the work’s chamber.• Two, for flow and expulsion, Hepa absolute filter – efficiency exceeding 99.999%, M.P.P.S. 0.3
Micron tested, following the C.E.N. regulation. U.S. Federal standard 209/E (class 100).• Easy system, from frontal side of the hood, to remove Hepa filter.• Carbon filter and air conveyor connector with anti-wind air grating, by request.• Two centrifugal anti-spark fans• Fan’s auto regulation to guarantee frontal barrier and laminar flow.• Frontal membrane key control panel with pilot light, IP 65 protection.• Laminar flow speed display in m/sec.• Expulsion air capacity display in m3/h.• Aspiration air speed display in m/sec.• Min.-max speed alarm for laminar flow and expulsion flow.• Filters’ digital hour counter of operation.• Germicide lamp’s digital hour counter of operation with timer.• External expulsion canalization prearrangement.• Automatic cycle program in decontamination.• Laminar flow’s average speed 0.40m/sec;• Noise Db (A) < 60.• Power supply 230V – 50Hz.• Electrical input: 700W + 440W.
m3/h aria in espulsionedisplay for air expulsion m3/h
velocità flusso laminare m3/secdisplay for laminar flow m3/sec
velocità aria in aspirazione mt/secdisplay for inlet air speed mt/sec
PANNELLO DI CONTROLLOALARMS PANNEL
71
BIO
HA
ZA
RD
SA
FETY
CA
BIN
ET
PESO
WEIGHT
DIMENSIONI ESTERNE
OUTER DIMENSIONS
DIMENSIONI PIANO DI LAVORO
WORK SURFACE DIMENSIONS
L X P X HW X D X H
L X P X HW X D X H
KG
KG
1260 X 590 X 650 MM
1500 X 590 X 650 MM
1800 X 590 X 650 MM
1350 X 760 X 1500 MM
1550 X 760 X 1500 MM
1850 X 760 X 1500 MM
200
220
240
Asalair Atlantic Biohazard is in conformity with the following law:• BRITISH STANDARD (BSI 5726-1992).• CE - EN 61010-1• 89/392/CEE - EN 61326 - 89/336 EEC• CEI 66.5 E CEI 62.25• U.S. FEDERAL STANDARD 209/E• UNI EN 12469Is complies with safety advice being stated by OMS.
LA CAPPA ASAL BIOHAZARD è conforme alle norme:• BRITISH STANDARD (BSI 5726-1992).• CE - EN 61010-1• 89/392/CEE - EN 61326 - 89/336 EEC• CEI 66.5 E CEI 62.25• U.S. FEDERAL STANDARD 209/E• UNI EN 12469È conforme alle raccomandazioni per la sicurezza deglioperatori sanitari espresse dalla OMS.
CAPPA BIOHAZARD ASALAIR “ATLANTIC”The Asalair biohazard hood mod. ATLANTIC, is a batteriologic safety cabinet CLASS II A, that exploiting air recy-cle, through Hepa filters, guarantee a non-contaminated zone where is possibile to work the product, preservingoperator and external ambient by contamination. The air’s frontal aspiration speed is costant 0,45 mt/sec becau-se all the functions are autocontrolled by microprocessor.The air’s flow is uniform and unidirectional consisting in parallel waste air’s stripes that move themself with samespeed in every point creating a homogeneus air’s draught without turbolences.The contaminated particles are filtered with another Hepa filter (if present with an activated carbon filter also)before to be conveied and ejcted in ambient through a second centrifugal fan.The vertical laminar flow hood mod. ATLANTIC has been maked to allow manipulations of various material in awaste ambient. It unites, with air’s ricycle system, the absolute safety by external contaminations with the pro-tection for the operator.It is a batteriologic safety cabinet (BIOHAZARD) with a work’s zone protect by a vertical laminar flow in class 100,guaranting the product by external contaminations or by turbolence of the laminar flow on the contaminated mate-rials in the work’s chamber.The contaminated particles are filtered with another Hepa filter (if present with an activated carbon filter also) befo-re to be conveied and eject in ambient through a second centrifugal fan. The laminar flow is filtered through a Hepafilter (high efficiency particulate air) - efficiency exceding 99.999% on. 0.3 µm. particles with DOP test, and gua-rantee highest performance than U.S. Federal 209/E (class 100) asked.The use prime components and materials, the working, the operator and ambient safety allow to classify theAsalair biohazard hood mod. ATLANTIC in accordance with BS 5726-UNI EN 12469-NSF 49 like a class II A, witha laminar flow speed of 0.40m/sec., convertible in class II B3, with a simple modify of the frontal flow speed.The hoods class IIA (in accordance with NSF 49: 1992) are different for the air volume recycled report in the wor-k’s area:• Type A (30% expulse air in the room – 70% ricirculated air) frontal air speed = 0.45m/sec.• Type B1 (70% expulse air to the external of the room – 30% ricirculated air) frontal air speed = 0.5m/sec.• Type B2 (100% expulse air to the external of the room) frontal air speed = 0.5m/sec.• Type B3 (30% expulse air to the external of the room – 70% ricirculated air) frontal air speed = 0.5m/sec.Expulse air, in the hood type A, is ricirculated in ambient, in the hood type B3 is canalized to the external of theroom.The compensation is possible with air aspiration through frontal opening that create a frontal barrier preventingthe contaminated aerosol’s leak.
74
Ci r
iser
viam
o il
dirit
to d
i app
orta
re s
enza
pre
avvi
so t
utte
le m
odifi
che
nece
ssar
ie p
er il
mig
liora
men
to d
el p
rodo
ttoW
e re
serv
e to
cha
nge
any
spec
ifica
tion
at o
ur p
rodu
cts
with
out
prio
r no
tice
Il prodotto è conforme alle seguenti Direttive: CEE – 73/23,89/392, 89/336, 91/368, 92/31, 93/44, 93/68, alle seguentiNorme: CEI EN 61010-1 (IEC 1010-1/CEI 66-5) alle seguenti LeggiNazionali: D.P.R.N. 547 27/4/1995 Legge N. 186 1/3/1968
Is in conformity with the following Directives: CEE – 73/23,89/392, 89/336, 91/638, 92/31, 93/44, 93/68 the followingRules: CEI EN 61010- 1 (IEC 1010-1/CEI 66-5) – the followingNational Laws: D.P.R. N. 547 27/4/1995 Law N. 186 1/3/1968
ACCESSORI A RICHIESTA• Cella di carboni attivi da inserire a cascata dopo
il filtro Hepa per l’aria in espulsione per lavora-zioni con vapori tossici.
• Modulo EXACARB - Sistema di filtrazione a car-boni attivi. Il modulo filtrante, completo di moto-ventilatore, a carbone attivo, consente la filtra-zione di sostanze tossiche (quali vapori e gaschimici) presenti all’interno della cabina primadella loro espulsione nell’ambiente. Il carboneattivo in granuli trattiene nelle sue molecole ivapori tossici permettendo così il controllo dellacontaminazione chimica dell’aria. Si ottiene per-tanto una totale sicurezza ambientale. Il modu-lo viene applicato sul camino della cappa.
• Raccordo convogliatore scarico esterno aria congriglia antivento.
• Pannello di chiusura completo di lampada ger-micida 30W.
• Tavolo di supporto dim. (LxPxA 1350 x 760 x 840 mm.)
• Cassettiera a 3 cassetti con ruote e chiave.
OPTIONAL ACCESSORIES• Carbon filter to put on HEPA filter for maximum
protection from toxic fumes.• EXACARB – Carbon filtration system, complete
with motor fan, allow to filter toxic or bed smel-ling fumes present inside the cabin beforetheir expulsion in the room. Exacarb system is placed on the hood pipe fitting.
• Front opening panel in stainless steel with ger-micide 30W lamp.
• Air conveyor connector with anti-wind air grating.• Hood support table
(WxDxH 1350 x 760 x 840 mm.)• Drawers set with 3 draws and wheels and key.