InTouch Ticket 3053798 Chemical Injection using Reda power cable with capillary tube Figure 1. Figure 1 shows the typical configuration (without down-hole barrier). This system included a packer, which is not common with continuous chemical injection. A special feedtrhu connector with a 3/8" capillary tube by-pass--in addition to SLB Page 1 document.doc Proprietary Information This document contains information proprietary to REDA, a Division of CAMCO, and is intended solely for the controlled use of the recipient. The contents are not to be reproduced or disclosed without prior written authorization. © REDA 1997 Chemical Tank Filter / Strainer Metering Pump Check Valve Reda, Bolt-On- Head Discharge Reda, Pump Reda, Intake/Gas Sep. Reda, Protector Reda, Motor Packer Reda, Composite Injection Tube ESP Power Cable. ( Flat or Round configuration available) Reda, Motor Guide SS Capillary tube CHEMICAL INJECTION SYSTEM Utilizing cable with capillary tube R E D A REDA 1 2 - - - 3 4 Calibration Column 5 R E D A

Capilar Installation

  • Upload
    luis

  • View
    118

  • Download
    3

Embed Size (px)

DESCRIPTION

Instalacion de tubos de inyeccion ESP

Citation preview

Figure 1

InTouch Ticket 3053798 Chemical Injection using Reda power cable with capillary tube

Figure 1.Figure 1 shows the typical configuration (without down-hole barrier). This system included a packer, which is not common with continuous chemical injection. A special feedtrhu connector with a 3/8" capillary tube by-pass--in addition to the three electric conductors--was used for this installation.

Are you using Sub Surface Safety Valves (SSSV)in the production tubing string? If the answer is no, there is no need to install a down-hole barrier in capillary tube.

The check valve (5)--installed at surface--is the physical barrier to prevent back-flow. In addition to this check valve, you can install a valve with electronic actuator in the injection line. A company such as Milton Roy-Flow Control Division http://www.miltonroy.com/ can help with the application of these valves.

In regards to your question on the termination of the capillary tubing and the physical attachment of the tubing to the equipment below the FCE splice, it can be very simple for vertical wells or more elaborated for deviated or high profile wells. It is more a plumbing job that has to be done in the Geo Market. We have not developed engineering procedures nor drawings.

Figure 2-a

Figure 2-b

Figure 2-a shows the simplest arrangement, using the same type of cable bands to attach the tubing to the motor, surveyor and pup-joint if used. The tubing is external to the pup-joint and is terminated in U shape. Lasalle protectors and encapsulated line can be used for additional protection of external tubing. (see figure 3). The A.O.P.C. LIUHUA COMPLETION DIAGRAM with Lasalle Downhole Chemical Injection Line in Figure 3 shows a more elaborated system.

In the internal tubing approach shown in Figure 2-b, the capillary tube is protected, and is terminated bending in a U shape, or Swagelok fittings (elbows, tees, etc) You can find information on fittings and tools required at http://www.swagelok.com/index.asp

The use of the Swagelok tube bender permits easy forming of the tubing in the field, or the pup-joint assembly could be pre-assembled and tested and then connected in the filed during installation

Figure 2-c

Figure 2-c includes a discharge manifold.

The use of the Swagelok tube bender permits easy forming of the tubing in the field, or the pup-joint assembly could be pre-assembled and tested and then connected in the filed during installation. Option 2-c would be preferable handled this way.

A.O.P.C. LIUHUA COMPLETION DIAGRAM with Lasalle Downhole Chemical Injection Line (3/8" Encapsulated stainless steel line)

Figure 3

Concerning to your question on availability of check valves for this type of installation, you are right, there are check valves available, for example Swagelock CH8 Series check valves. I downloaded the catalog below for your reference.

You can find additional information at: http://www.swagelok.com/Two issues to consider when installing a check valve at the bottom of the capillary tube , as opposed to the check valve at surface as illustrated in Figure 1, are first, the possibility of obstruction of the check valve at downhole conditions, and second the pressure rating of the capillary tube.

Obstruction of the check valve.

The concern is that debris, scale, wax, or other substance could interfere the operation of the check valve.

Working Pressure rating of the capillary tube.

The most common capillary tube we use is SS 316L, 3/8in O.D., 0.049in wall. The internal working pressure for this tube is between 4,800 to 4,900 psi. This theortical internal working pressure is de-rated when operating at high temperatures. One manufacturer (GIBSON TUBE, http://www.gibsontube.com ) provides the follwing correction factors for SS 316L: 0.93, 0.84, 0.75 for temperatures of 100 F, 300F, and 500 F respectively.

If the capillary tube is run with its end open, the fluid enters the tubing and therefore, the internal pressure is the same as the external pressure.

If there is a check valve at the lower end of the capillary tube, the fluid cannot enter the tube, therefore the external pressure will be higher, unless the tubing is continually filled with liquid while it is run. This is not usually a problem, but something to consider in deeper applications. The external pressure will depend on the fluid level and the fluids specific weight.

This configuration or a chemical injection mandrel should be considered only if a downhole barrier, such as Sub Surface Safety Valves (SSSV) are installed in the production tubing string.Proprietary Information

This document contains information proprietary to REDA, a Division of CAMCO,

and is intended solely for the controlled use of the recipient. The contents are not

to be reproduced or disclosed without prior written authorization.

REDA 1997

Chemical

Tank

Filter /

Strainer

Metering

Pump

Check

Valve

Reda, Bolt-On-

Head Discharge

Reda, Pump

Reda,

Intake/Gas Sep.

Reda, Protector

Reda, Motor

Packer

Reda, Composite Injection Tube ESP Power Cable. ( Flat or Round configuration available)

Reda, Motor Guide

SS Capillary tube

CHEMICAL INJECTION SYSTEM

Utilizing cable with capillary tube

REDA

REDA

1

2

-

-

-

3

4

Calibration

Column

5

EMBED Word.Document.8 \s

REDA

EMBED AcroExch.Document

EMBED AcroExch.Document

Diego A. NarvaezPage 4Cap-Tube.doc?ts=MjAwNToxMjoyMTowMTowOTo0NQ==&filename=Cap-Tube.doc&forcedownload=no

_1066653463.pdf

FMC Horizontal Sub Sea Tubing Hanger(18-1/2" OD, 4" production bore, 5,000 psi rated)

Halliburton Adjustable Union Assembly

Lasalle Corrosion Monitoring Tool(Installed in selected wells only)

Camco Downhole Safety Valve Assembly(c/w Halliburton flow couplings)

Halliburton Annular Circulation Valve Assembly(Set to shear circa 1,500 psi differential pressure annulus/tubing)

Packer Sub AssemblyNodeco Re-settable Packer & Halliburton Swivel/Adjustable Union(Packer setting initiates at 1,100 psi, complete at 3,000 psi.Packer unseated by circa 50,000 lbs over pull)

Camco Check and Shear Valve Assembly(Set to shear circa 4,200 psi differential pressure tubing/annulus)

Phoenix Flowmeter Assembly(c/w turbine flowmeter & discharge pressure sensor)

Reda Electric Submergible Pump (ESP) Assemblycomprising the following sections:

(a) Reda HN13500, 73 Stage, 562 Series Tandem Pump Section

(b) Reda BPBSL-HL, 540 Series Tandem Protector Section

(c) Reda 540HP, 562 Series Tandem Motor Section

Phoenix Multi-Sensor Assembly(c/w intake pressure, intake temperature & motor oil temperature sensors)

Lasalle Stinger Assembly(c/w chemical injection anchor, burst disc - rupture pressure circa 2,500psi &corrosion monitors)

Tronic Wet Mateable Electric Connector (WMEC)(Electrical Rating: 5,000 volts, 125 amps)

Tubing, 4-1/2" 12.6 ppf L80 New Vam, (2 Joints)

Redablack Main ESP Power Cable(#1 AWG, compacted, round cable with galvanised armour)(Electrical Rating: 5,000 volts, 125 amps)

Lasalle Downhole Safety Valve Hydraulic Control Line(3/8" Encapsulated stainless steel line)

Main Tubing String, 5" 15.0 ppf L80 New Vam Tubing(Completion assemblies utilise 4-1/2" 12.6 ppf L80 New Vam tubing)

9-5/8" 47 ppf L80 Casing

BIW Packer Penetrator System(c/w 50 ft Redablack upper pigtail & 200 ft lower motor lead extension)(Electrical Rating: 5,000 volts, 140 amps)

Tubing, 4-1/2" 12.6 ppf L80 New Vam, (2 Joints)

Phoenix Flowmeter and Discharge Pressure Cables(3/8" flowmeter electric cable & 1/4" discharge pressure hydraulic line)

Reda 540 Series Motor Lead Extension (MLE) & Motor Pothead(#4 AWG, KELB, flat cable with monel armour, length: 200 ft nominal)(Electrical Rating: 5,000 volts, 125 amps)

Reda 562 Series Motor Adapter(c/w electrical connections for Phoenix Multi-Sensor)

Lasalle Downhole Chemical Injection Line(3/8" Encapsulated stainless steel line)

Baker "HYFLO II" H40 Hydraulic Set Liner Hanger

Horizontal Reservoir Section(completed with 7" 23.0 ppf L80 Perforated Liner)

A.O.P.C. LIUHUA 11-1 ESP Completion Diagram

2

4

6

8

11

13

15

16

18

21

23

2

11

8

6

13

15

16

18

23

4

21

1

3

5

7

9

10

12

14

17

19

20

22

24

25

1

10

7

5

12

17

19

24

3

22

9

14

20

25

_1066653866.pdf

Check Valves

www.swagelok.com

CH Series Working pressures up to 6000 psig (413 bar)

Cracking pressures fixed from 1/3 to 25 psi (0.02 to 1.7 bar)

Swagelok tube fitting, NPT and ISO pipe, and VCR and VCO faceseal fitting end connections in 1/8 through 1 in. and 6 through25 mm sizes

316 stainless steel materials

CH Series Check Valves

2

Cracking and Reseal

Pressures at 70F (20C)

Poppet with bondedelastomer seal

Poppet stop

O-ring seals body halves Backup ring supports O-ring

Features

Nominal Spring Size,

psi (bar)

Cracking PressureRange,psi (bar)

Minimum ResealPressure,psi (bar)

1/3 (0.02) Up to 3 (0 to 0.20) 6 (0.41)back pressure

1 (0.06) Up to 4 (0 to 0.27) 5 (0.34)back pressure

5 (0.34) 3 to 9 (0.20 to 0.62) 2 (0.13)back pressure

10 (0.68) 7 to 15 (0.48 to 1.0) 3 (0.20)

25 (1.7) 20 to 30 (1.3 to 2.0) 17 (1.1)

For more information about pressure ratings of valves with tube fitting endconnections, see Swagelok Tubing Data, MS-01-82. Valves with female pipe ends have lower pressure ratings. See Dimensions,

page 4.

Valves that are not actuated for a period of time maycrack initially at higher than subsequent crackingpressures.

Cracking pressure the upstream pressure at which the firstindication of flow occurs.

Reseal pressure the upstream pressure at which there is noindication of flow.

Technical DataSeries CH4 CH8 CH16

End ConnectionSizes

1/8 and 1/4 in.;6 mm

3/8 and 1/2 in.;8, 10, and 12 mm

3/4 and 1 in.;22 and 25 mm

Nominal CrackingPressures,psi (bar)

1/3, 1, 5, 10, and 25(0.02, 0.06, 0.34, 0.68, and 1.7)

Working andBack Pressuresat 70F (20C),psig (bar)

6000 (413) 5000 (344)

TemperatureRating,F (C) Fluorocarbon FKM seals: 10 to 400 (23 to 204)

Flow Coefficient(see Flow Data) 0.67 max 1.8 max 4.7 max

ComponentMaterial Grade/

ASTM Specification

1 Inlet body316 SS/A479

2 Indicator ring

3 Poppet Fluorocarbon FKM-bonded 316 SS/A479

4 Poppet stop 316 SS/A240

5 Spring 302 SS/A313

6 O-ring Fluorocarbon FKM

7 Backup ring PTFE/D1710

8 Outlet body 316 SS/A479

1

2

34

5

6

7

8

Fluorocarbon-based lubricant.

TestingEvery CH series check valve is factory tested for crackand reseal performance.

Materials of Construction

Cleaning and PackagingEvery CH series check valve with VCR end connections is specially cleaned and packaged in accordance withSwagelok Specification SC-11. CH series check valveswith other end connections are cleaned and packaged inaccordance with Swagelok Specification SC-10; specialcleaning and packaging in accordance with SpecificationSC-11 is available as an option.

CH Series Check Valves

3

Flow Data at 70F (20C)

CH8 Series

CH16 Series

CH4 Series

CH8 Series

CH16 Series

Air Flow Water Flow

25 psi (1.7 bar) spring

CH4 Series

Air Flow, std ft3/min

Air Flow, std L/min

Water Flow, U.S. gal/min

Water Flow, L/min

Air Flow, std ft3/min

Air Flow, std L/min

Water Flow, U.S. gal/min

Water Flow, L/min

Air Flow, std ft3/min

Air Flow, std L/min

Water Flow, U.S. gal/min

Water Flow, L/min

10 psi(0.68 bar)

1 psi (0.06 bar)

25 psi (1.7 bar) spring

10 psi (0.68 bar)

1 psi (0.06 bar)

25 psi (1.7 bar) spring

10 psi (0.68 bar)

1 psi (0.06 bar)

25 psi (1.7 bar) spring

1 psi (0.06 bar)

25 psi (1.7 bar) spring

1 psi (0.06 bar)

25 psi (1.7 bar) spring

10 psi (0.68 bar)

1 psi (0.06 bar)

10 psi(0.68 bar)

10 psi(0.68 bar)

CH Series Check Valves

4

ABD CC

Dimensions

End Connection PressureRating,

psig (bar)

Dimensions,in. (mm)

Type Size A BC

Nut HexD

Body Hex

Swagelok tube fitting

1/8 in.

6000 (413)

SS-CHS2- 2.27 (57.7)

1.04 (26.4)

7/16

11/16

CH4 Series

1/4 in. SS-CHS4-2.43 (61.7)

9/16

6 mm SS-CHS6MM- (14)

Female NPT 1/4 in. SS-CHF4- 2.13 (54.1)

Male NPT1/8 in. SS-CHM2- 1.79 (45.5)

1.04 (26.4)1/4 in. SS-CHM4- 2.17 (55.1)

Female ISO 1/4 in. SS-CHF4RT- 2.28 (57.9)

Male ISO 1/4 in. SS-CHM4RT- 2.17 (55.1)

1.04 (26.4)Male VCO fitting 1/4 in. SS-CHVCO4- 1.98 (50.3)

Male VCR fitting 1/4 in. SS-CHVCR4- 2.28 (57.9)

CH8 Series

Swagelok tube fitting

3/8 in.

6000 (413)

SS-CHS6- 2.75 (69.9)

1.23 (31.2)

11/16

1

1/2 in. SS-CHS8- 2.96 (75.2) 7/8

8 mm SS-CHS8MM- 2.70 (68.6) (16)

10 mm SS-CHS10MM- 2.80 (71.1) (19)

12 mm SS-CHS12MM- 2.96 (75.2) (22)

Female NPT3/8 in. 5000 (344) SS-CHF6- 2.55 (64.8)

1/2 in. 4600 (316) SS-CHF8- 3.03 (77.0) 1116

Male NPT3/8 in.

6000 (413)SS-CHM6- 2.36 (59.9)

1.23 (31.2) 11/2 in. SS-CHM8- 2.73 (69.3)

Female ISO 1/2 in. 4600 (316) SS-CHF8RT- 3.29 (83.6) 1116

Male ISO 1/2 in. 6000 (413) SS-CHM8RT- 2.73 (69.3) 1.23 (31.2)

1

Female SAE/MS 1/2 in. 4600 (316) SS-CHF8ST- 2.74 (69.6)

Male SAE/MS 1/2 in.6000 (413)

SS-CHM8ST- 2.48 (63.0) 1.61 (40.9)

Male VCO fitting 1/2 in. SS-CHVCO8- 2.35 (59.7)1.23 (31.2)

Male VCR fitting 1/2 in. SS-CHVCR8- 2.73 (69.3)

CH16 Series

Swagelok tube fitting

3/4 in. 5000 (344) SS-CH16S12- 3.52 (89.4) 1.78 (45.2) 118

158

1 in. SS-CH16S16- 3.88 (98.6)

1.79 (45.5)22 mm SS-CHS22MM- 3.48 (88.4)

25 mm SS-CHS25MM- 3.88 (98.6)

Female NPT3/4 in. 4300 (296) SS-CH16F12- 3.23 (82.0)

1 in. 4100 (282) SS-CH16F16- 3.83 (97.3)

Male NPT3/4 in.

5000 (344)SS-CHM12- 3.29 (83.6) 1.79 (45.5)

1 in. SS-CHM16- 3.67 (93.2) 1.80 (45.7)

Female ISO3/4 in. 4300 (296) SS-CH16F12RT- 3.55 (90.2)

1 in. 4100 (282) SS-CH16F16RT- 3.83 (97.3)

Male ISO3/4 in

5000 (344)

SS-CHM12RT- 3.35 (85.1) 1.79 (45.5)

1 in. SS-CHM16RT- 3.67 (93.2) 1.80 (45.7)

Male VCO fitting3/4 in. SS-CHVCO12-

2.90 (73.7)1.77 (45.0)

1 in. SS-CHVCO16- 1.78 (45.2)

Male VCR fitting 3/4 in. SS-CHVCR12- 3.78 (96.0) 1.79 (45.5)

(40)

(32)

112

Dimensions shown with Swagelok nuts finger-tight, where applicable. Dimensions in inches and (millimeters) are for reference only and are subject to change. Reference specifications: ISO 7/1, BS21, DIN -2999, JIS B0203.

Ordering InformationTo order, add the desired crackingpressure designator as a suffix tothe basic ordering number.Example: SS-CHS8-10.

3500 (241)

4700 (323)

5000 (344)

Cracking Pressure, psi (bar) Designator1/3 (0.02) 1/3

1 (0.06) 1

5 (0.34) 5

10 (0.68) 10

25 (1.7) 25

3000 (206)

Basic OrderingNumber

CH Series Check Valves

5

Special Applications

Sour Gas Valves For sour gas (hydrogen sulfide-bearing hydrocarbon)

applications. Materials for wetted components are selected in

accordance with NACE Specification MR0175 forsulfide stress cracking-resistant materials.

Ethylene propylene seals with PTFE backup ring.

Technical DataPressure Rating at 70F (20C)

CH4 and CH8 series: 5000 psig (344 bar)CH16 series: 4700 psig (323 bar)

Temperature Rating50 to 300F (45 to 148C)

Nominal Cracking Pressures1/3, 1, and 5 psi (0.02, 0.06, and 0.34 bar)

End Connections 1/4, 3/8, 1/2, 3/4, and 1 in. Swagelok tube fittings

Materials of ConstructionBody, poppetalloy R-405/B164Sealsethylene propyleneSpringalloy X-750/AMS 5699All other materials and lubricant same as standardproduct. See Materials of Construction, page 2.

Ordering InformationTo order, substitute M for SS and insert -SG into the basicordering number, followed by the desired crackingpressure designator.Example: M-CHS8-SG-1/3.

Maintenance KitsSpring kits and seal kits are available for retrofit ormaintenance. See Swagelok Check Valve MaintenanceKits, MS-02-115-SCS.

Options

Seal MaterialsFluorocarbon FKM seal materials are standard. Otherelastomer seals (poppet bonding material and O-ring) areavailable. To order, insert the desired seal designator intothe valve ordering number.Example: SS-CHM6-BU-10.

SealMaterial Designator

Temperature Rating,F (C)

Kalrez

Buna N -BU40 to 250 (40 to121)

-KZ

Neoprene -NE

10 to 400 (23 to 204)

Ethylene propylene -EP 50 to 300 (45 to 148)

Aflas -AF 0 to 380 (17 to 193)

Fluorocarbon-Free Valves For systems where PTFE and fluorinated compounds

cannot be tolerated. Ethylene propylene seal material with PEEK

(polyetheretherketone) backup ring; all other materialsare standard.

Technical DataPressure Rating at 70F (20C)

Same as standard product. See Technical Data,page 2.

Temperature Rating50 to 300F (45 to 148C)

Nominal Cracking PressuresSame as standard product. See Technical Data,page 2.

End ConnectionsAll end connection types and sizes from the tableon page 4.

Materials of ConstructionSealsEthylene propyleneBackup ringPEEKLubricanthydrocarbon basedAll other materials same as standard product. SeeMaterials of Construction, page 2.

Ordering InformationTo order, insert -PK into the basic ordering number,followed by the desired cracking pressure designator.Example: SS-CHS2-PK-1.

Special AlloysValve bodies of alloy R-405 are available in some sizes.Contact your Swagelok representative for more information.

Swagelok, VCR, VCO TM Swagelok CompanyAflas TM Asahi Glass Co., Ltd.Kalrez TM DuPont 2000 Swagelok CompanyPrinted in U.S.A.April 2000, R3MS-01-75

Safe Product SelectionWhen selecting products, the total system design mustbe considered to ensure safe, trouble-free performance.Function, material compatibility, adequate ratings,proper installation, operation, and maintenance are theresponsibilities of the system designer and user.

Caution: Do not mix or interchange parts with those ofother manufacturers.