Cabletron SNMP Bridges Management Module Guide

®

Page 2: Cabletron SNMP Bridges MMG (9030368)

9030368 E9i

Notice

Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made.

The hardware, firmware, or software described in this manual is subject to change without notice.

IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.

Virus Disclaimer

Cabletron has tested its software with current virus checking technologies. However, because no anti-virus system is 100% reliable, we strongly caution you to write protect and then verify that the Licensed Software, prior to installing it, is virus-free with an anti-virus system in which you have confidence.

Cabletron Systems makes no representations or warranties to the effect that the Licensed Software is virus-free.

Copyright © April, 1998, by Cabletron Systems, Inc. All rights reserved.

Printed in the United States of America.

Order Number: 9030368 E9

Cabletron Systems, Inc.P.O. Box 5005Rochester, NH 03866-5005

SPECTRUM

, the

SPECTRUM

IMT/VNM

logo,

DCM

,

IMT

, and

VNM

are registered trademarks, and

SpectroGRAPH

,

SpectroSERVER

,

Inductive Modeling Technology

,

Device Communications Manager

, and

Virtual Network Machine

are trademarks of Cabletron Systems, Inc.

C++

is a trademark of American Telephone and Telegraph, Inc.

UNIX

is a trademark of UNIX System Laboratories, Inc.

OSF/Motif

and

Motif

are trademarks of the Open Software Foundation, Inc.

X Window System

is a trademark of X Consortium, Inc.

Ethernet

is a trademark of Xerox Corporation.

Page 3: Cabletron SNMP Bridges MMG (9030368)

ii

Cabletron SNMP BridgesManagement Module Guide

Restricted Rights Notice

(Applicable to licenses to the United States Government only.)

1. Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013.

Cabletron Systems, Inc., 35 Industrial Way, Rochester, New Hampshire 03866-5005.

2. (a) This computer software is submitted with restricted rights. It may not be used, reproduced, or disclosed by the Government except as provided in paragraph (b) of this Notice or as otherwise expressly stated in the contract.

(b) This computer software may be:

(1) Used or copied for use in or with the computer or computers for which it was acquired, including use at any Government installation to which such computer or computers may be transferred;

(2) Used or copied for use in a backup computer if any computer for which it was acquired is inoperative;

(3) Reproduced for safekeeping (archives) or backup purposes;

(4) Modified, adapted, or combined with other computer software, provided that the modified, combined, or adapted portions of the derivative software incorporating restricted computer software are made subject to the same restricted rights;

(5) Disclosed to and reproduced for use by support service contractors in accordance with subparagraphs (b) (1) through (4) of this clause, provided the Government makes such disclosure or reproduction subject to these restricted rights; and

(6) Used or copied for use in or transferred to a replacement computer.

(c) Notwithstanding the foregoing, if this computer software is published copyrighted computer software, it is licensed to the Government, without disclosure prohibitions, with the minimum rights set forth in paragraph (b) of this clause.

(d) Any other rights or limitations regarding the use, duplication, or disclosure of this computer software are to be expressly stated in, or incorporated in, the contract.

(e) This Notice shall be marked on any reproduction of this computer software, in whole or in part.

Page 4: Cabletron SNMP Bridges MMG (9030368)

9030368 E9iii

Contents

Preface

What is in this Guide ........................................................................................................... xiConventions ......................................................................................................................... xiiRelated SPECTRUM Documentation................................................................................. xiiOther Related Documentation ............................................................................................ xiiGetting Help ....................................................................................................................... xiii

Chapter 1 Introduction

What is in this Chapter...................................................................................................... 1-1SNMP Bridge Management Module.................................................................................. 1-1

Chapter 2 Device View

What is in this Chapter...................................................................................................... 2-1Accessing the Device View ................................................................................................. 2-1SNMP NB20E and NB25E Device Views.......................................................................... 2-2

SNMP NB20E and SNMP NB25E LEDs.................................................................... 2-4SNMP NB30 Device View .................................................................................................. 2-5

SNMP NB30 LEDs....................................................................................................... 2-7Remote V.35 and RS449 Port ................................................................................ 2-7Remote DSX-1 Port................................................................................................ 2-7Ethernet Port ......................................................................................................... 2-8

SNMP NB30 Front Panel Switches............................................................................. 2-8EFDMIM Device View........................................................................................................ 2-9

Accessing the Hub Logical/Physical Device View....................................................... 2-9Hub Logical Device View ........................................................................................... 2-10

Gauge Control Panel............................................................................................ 2-12IRM2, IRBM, or IRM3 Hub Physical Device Views ................................................. 2-15

MMAC Device Panel............................................................................................ 2-15EFDMIM Logical MIM Representation.................................................................... 2-16

Logical Gauges..................................................................................................... 2-18Gauge Mode ......................................................................................................... 2-19

EFDMIM Physical MIM Representation.................................................................. 2-19EFDMIM LEDs.................................................................................................... 2-22

IRM Hub Physical Device View................................................................................. 2-23MMAC Device Statistics Panel ........................................................................... 2-23

Configuring the EFDMIM in an IRM or IRBM Device View................................... 2-25Configuring the EFDMIM in an IRM2 or IRM3....................................................... 2-26

Page 5: Cabletron SNMP Bridges MMG (9030368)

Cabletron SNMP Bridgesiv Management Module Guide

Chapter 2 Device View (continued)

Copying the EFDMIM into a Location or Topology View .........................................2-27Changing MIM Representations................................................................................2-28

Changing MIM Representations on the Entire Hub..........................................2-28Changing MIM Representations Using the Menu Bar ......................................2-28Changing MIM Representations Using the Mouse ............................................2-29

Clearing Duplicate EFDMIM Address Alarms .........................................................2-29Case #1..................................................................................................................2-30Case #2..................................................................................................................2-30

EFDMIM Generic Views ............................................................................................2-31

Chapter 3 Application Views

What is in this Chapter ......................................................................................................3-1Accessing the Application View..........................................................................................3-1NB20E, NB25E, and NB30 Application Views ..................................................................3-3

HASPART Panel .........................................................................................................3-11EFDMIM Application View ..............................................................................................3-11

Ring Table ...................................................................................................................3-11HASPART Panel .........................................................................................................3-13

Chapter 4 Configuration Views

What is in this Chapter ......................................................................................................4-1Accessing the Configuration View......................................................................................4-1NB20E, NB25E, and NB30 Configuration Views ..............................................................4-3

Model Configuration.....................................................................................................4-3Device Configuration ....................................................................................................4-3EFDMIM Configuration View......................................................................................4-8

Model Configuration ..............................................................................................4-8Device Configuration..............................................................................................4-9

Chapter 5 Diagnostic Views

What is in this Chapter ......................................................................................................5-1Accessing the Diagnostic View ...........................................................................................5-1SNMP NB20E, SNMP NB25E and NB30 Diagnostic View..............................................5-2EFDMIM Diagnostic View..................................................................................................5-3

Bridge Port Table ..........................................................................................................5-4

Page 6: Cabletron SNMP Bridges MMG (9030368)

9030368 E9v

Chapter 6 Performance Views

What is in this Chapter...................................................................................................... 6-1Accessing the Performance View ....................................................................................... 6-1NB20E, NB25E and NB30 Performance View .................................................................. 6-2EFDMIM Performance View.............................................................................................. 6-3

Packet Breakdown Pie Chart ...................................................................................... 6-4Bridge Port Table ......................................................................................................... 6-4

Port Performance View....................................................................................................... 6-5SNMP NB20E and NB25E Port Performance View................................................... 6-5EFDMIM Port Performance View ............................................................................... 6-9

Port Packet Breakdown Pie Chart...................................................................... 6-10SNMP NB30 Local Port Performance View.............................................................. 6-11SNMP NB30 Remote Port Performance View .......................................................... 6-16

Chapter 7 Event and Alarm Messages

What is in this Chapter...................................................................................................... 7-1NB20E, NB25E, and NB30 Events and Alarms ............................................................... 7-2

Index

Page 7: Cabletron SNMP Bridges MMG (9030368)

viiiCabletron SNMP Bridges

Management Module Guide

Page 8: Cabletron SNMP Bridges MMG (9030368)

9030368 E9ix

Tables

Chapter 2 Device View

Table 2-1. Gauge Selected Attribute Colors......................................................................... 2-13Table 2-2. Horizontal Bar Gauge Statistic Colors............................................................... 2-18Table 2-3. Horizontal Bar Gauge Statistic Colors............................................................... 2-24

Chapter 3 Application Views

Table 3-1. Bridge Database View Special Database Information Fields ............................. 3-3Table 3-2. Bridge Database View Acquired Database Information Fields .......................... 3-4Table 3-3. Bridge Database View Permanent Database Information Fields....................... 3-5Table 3-4. Permanent Database Static Address Filtering Options...................................... 3-6Table 3-5. Permanent Database Information View Fields ................................................... 3-7Table 3-6. Acquired Database Table Static Address Filter Options .................................... 3-8Table 3-7. Acquired Database Information View Fields ....................................................... 3-9Table 3-8. Special Database New Database Information ..................................................... 3-9Table 3-9. Special Database Add an Entry View Options .................................................. 3-10Table 3-10. Possible FDDI Ring States.................................................................................. 3-12Table 3-11. Possible EFDMIM Duplicate Address Indications ............................................ 3-12

Chapter 4 Configuration Views

Table 4-1. Bridge Setup Information View Parameters........................................................ 4-6Table 4-2. Possible EFDMIM CFM States........................................................................... 4-10Table 4-3. Possible EFDMIM RMT States........................................................................... 4-11Table 4-4. Configuration View Jumper Setting Fields ....................................................... 4-12

Chapter 6 Performance Views

Table 6-1. Port Status Messages ............................................................................................ 6-6Table 6-2. Port Topology Settings View Fields.................................................................... 6-15

Chapter 7 Event and Alarm Messages

Table 7-1. Events and Alarms ................................................................................................ 7-2

Page 9: Cabletron SNMP Bridges MMG (9030368)

xCabletron SNMP Bridges

Management Module Guide

Page 10: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Prefacexi

Preface

Use this guide if you are going to manage a Cabletron SNMP Bridge through SPECTRUM. Before reading this guide, you should be familiar with SPECTRUM’s functions as described in the Operations and Administration documentation. You should also be familiar with any network

management and hardware requirements described in the related hardware documentation.

What is in this Guide

The following chapter descriptions outline the organization of the

Cabletron SNMP Bridges Management Module Guide

.

Chapter Description

Chapter 1

Introduction

Describes the Cabletron SNMP Bridges management module and model types.

Chapter 2

Device Views

Describes the Device Views available for each Cabletron SNMP Bridge model type.

Chapter 3

Application Views

Describes the Application Views available for each Cabletron SNMP Bridge model type.

Chapter 4

Configuration Views

Describes the Configuration View available for each Cabletron SNMP Bridge model type.

Chapter 5

Diagnostic

Views

Describes the Diagnostic View available for each Cabletron SNMP Bridge model type.

Chapter 6

Performance

Views

Describes the Performance View available for each Cabletron SNMP Bridge model type.

Chapter 7

Event and Alarm

Messages

Contains a listing and explanation of the alarm and event messages generated in the Event Log or Alarm View for the Cabletron SNMP Bridge model types.

Page 11: Cabletron SNMP Bridges MMG (9030368)

Conventions

Prefacexii

Cabletron SNMP BridgesManagement Module Guide

Conventions

In this manual, the following conventions are used:

• Command names are printed in

bold

; for example,

Clear

or

Save & Close

.

• Menu selections to access a view are printed in

bold

; for example,

Configuration

or

Detail

.

• Buttons are represented by a shadowed box; for example, .

Related SPECTRUM Documentation

Refer to the Operations, Administration, and the following documentation for more information on using SPECTRUM:

SPECTRUM Report Generator User’s Guide

Getting Started with SPECTRUM for Operators

Getting Started with SPECTRUM for Administators

How to Manage Your Network with SPECTRUM

Other Related Documentation

Refer to the following documentation for more information on managing TCP/IP-based networks:

LAN Troubleshooting Handbook

, Mark Miller (1989, M&T Publishing, Inc.)

The Simple Book — An Introduction to Management of TCP/IP-based Internets

, Marshall T. Rose, Performance Systems International, Inc.

Computer Networks

, Andrew S. Tanenbaum, Prentice-Hall, Inc.

Local Area Networks, Architectures and Implementations

, James Martin & Kathleen K. Chapman for the Arben Group, Inc. (1989, Prentice-Hall, Inc.)

Getting Help

If you need additional support for this SPECTRUM Network Management product, or have any questions, comments, or suggestions concerning this

Help

Page 12: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Prefacexiii

Getting Help

manual, contact Cabletron Systems Technical Support at one of the following regional addresses.

Location Mail FAX Telephone

North America Cabletron Systems, Inc.P. O. Box 5005Rochester, NH 03866-5005

Email:

[email protected]

603-337-3075 603-337-3500

Europe Cabletron Systems, Ltd.Network HouseNewbury Business ParkLondon Road, NewburyBerkshire, England RG13 2PZ

Email:

[email protected]

(*)-44-635-552062 (*)-44-635-580000

Pacific Cabletron Systems, Inc.Allambie Grove Estate25 French’s Forest Road EastFrench’s Forest, NSW 2086Sydney, Australia

Email:

[email protected]

(*)-61-2-950-5950 (*)-61-2-950-5900

Japan Cabletron Systems, KKHamamatsucho MK Bldg.4th Floor1-4-12 Kaigan, Minato-KuTokyo 101 Japan

Email:

[email protected]

(*)-81-3-3459-1985 (*)-81-3-3459-1981

Singapore Cabletron Systems, Inc.85 Science Park Drive#03-03/04The CavendishSingapore 051

Email:

[email protected]

(*)-65-7763382 (*)-65-7755355

Germany Cabletron Systems GmbHDreieich Park1m Gefierth 13d63303 DreieichFrankfurt, Germany

Email:

[email protected]

(*)-49-610-39910 (*)-49-610-3991109

*International Operator Code

Questions About SPECTRUM Documentation?

Send your questions, comments or suggestions regarding SPECTRUM documentation to the Technical Communications Department directly via the following internet address:

[email protected]

Page 13: Cabletron SNMP Bridges MMG (9030368)

Getting Help

Prefacexiv

Cabletron SNMP BridgesManagement Module Guide

Page 14: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Introduction1-1

Chapter 1

Introduction

What is in this ChapterThis chapter describes the SPECTRUM Management Module for the Cabletron SNMP Bridge family of devices. It also provides the Model Type Names assigned to the SNMP Bridges in SPECTRUM. The Model Type Name refers to the template used to specify device attributes, actions, and associations for device models in SPECTRUM.

SNMP Bridge Management ModuleThe SPECTRUM SNMP Bridge Management Module manages the Cabletron SNMP Bridge family of devices by using the SNMP network management agent and the Management Information Bases (MIBs), included with the management module.

There are four SPECTRUM model type names for the Cabletron SNMP Bridge Devices, three for the standalone models (Bdg_CSI_SNB20, Bdg_CSI_SNB25, BdgCSINB30), and one for the MMAC chassis module (Bdg_CSI_EFDMIM).

Bdg_CSI_SNB20: An NB20E bridge managed through the Simple Network Management Protocol (SNMP).

Bdg_CSI_SNB25: An NB25E bridge managed through SNMP.

BdgCSINB30: An NB30 T1 Remote Bridge managed through SNMP. Most functions are like the NB25E but there are some differences noted throughout the manual. NB30 bridges work in pairs.

Page 15: Cabletron SNMP Bridges MMG (9030368)

SNMP Bridge Management Module

Introduction1-2

Cabletron SNMP BridgesManagement Module Guide

Bdg_CSI_EFDMIM: An EFDMIM Ethernet to FDDI bridging MIM designed for installation in a Cabletron MMAC hub device and managed through SNMP.

If you are running a previous version of SPECTRUM, the following user interface aspects may differ from those in SPECTRUM version 4.0:

• Order and names of menu selections

• Navigational features (mouse button functionality)

For information about menu selections and navigating within previous versions of SPECTRUM, refer to the SPECTRUM System User’s Guide. For information about menu selections and navigating within SPECTRUM version 4.0, refer to SPECTRUM Views and SPECTRUM Menus.

Page 16: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-1

Chapter 2

Device View

What is in this ChapterThis chapter provides a description of the Device View for the SNMP Bridges Management Module. This description includes an explanation of the menu bar access to the various views used to control and monitor the bridge, and how to use the Device View to view EFDMIMs, access SPECTRUM generic views, and monitor the performance of the bridges.

The Device View shows an actual representation of the bridge configuration. The representation is updated after each SPECTRUM polling cycle to show any changes in the bridge configuration.

Accessing the Device ViewYou can access the Device View using one of the following methods (refer to Figure 2-1 ):

• Double-click on the Device View button of the bridge icon.

• Highlight the bridge icon and select Device from the Icon Subviews menu.

Management Module Guide for the Cabletron Systems SNMP Bridges

Page 17: Cabletron SNMP Bridges MMG (9030368)

SNMP NB20E and NB25E Device Views

Device View2-2

Cabletron SNMP BridgesManagement Module Guide

Figure 2-1. Accessing the SNMP NB20E/NB25E/NB30 Device View

SNMP NB20E and NB25E Device ViewsThis view represents the physical status of the SNMP Bridge device and provides menu access to the generic views. These generic views allow you to access network configuration information as well as traffic flow and error data for your bridge. The Device View creates an icon manager that represents each of the ports associated with the bridge model.

The Device View periodically polls the bridge model in the SpectroSERVER database to determine if any configuration changes have occurred. If a configuration change has occurred, the configuration is changed within the Device View to match the model in the SpectroSERVER database. Figure 2-2 provides and example of an SNMP Bridge NB-20E Device View.

Double-click

10

1

.1

.01

Select Device

CloseNavigateAlarmsPerformanceNotes...UtilitiesZoomConfigurationDiagnosticAcknowledge

Flash Green EnabledApplicationDeviceDevTop

Page 18: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-3

SNMP NB20E and NB25E Device Views

Figure 2-2. Cabletron SNMP NB-20E Bridge Device View

* File View Device MenuHelp?

Primary Landscape 0x00400000 - VNM Host - MIS of type Hub_CSI_SNB20

NB-20EETHERNET/IEEE 802.3 BRIDGING UNITWITH REMOTE LANVIEW® AND MANAGEMENT

PORT2 1

POK

CP

RCV

XMTON LINE

STAND BY

ROOT

FORWARDBROADCAST

Page 19: Cabletron SNMP Bridges MMG (9030368)

SNMP NB20E and NB25E Device ViewsSNMP NB20E and SNMP NB25E LEDs

Device View2-4

Cabletron SNMP BridgesManagement Module Guide

SNMP NB20E and SNMP NB25E LEDs

The LEDs on the bridge front panels in the Device View are animated to reflect the state of the LEDs as of the last poll cycle. The LEDs turn on or off to match the bridge on the network. For detailed information on the LED definitions, and the operation of your bridge, refer to the documentation that accompanied your bridge. The following is a general definition of specific LEDs for the SNMP NB20E and SNMP NB25E bridge model types.

ON LINEWhen this green LED is on, the bridge is receiving power, and has completed its power up self test. The bridge is capable of forwarding packets.

STAND BYWhen this yellow LED is on, the bridge is in “STANDBY” mode and not capable of forwarding packets across the link.

XMT (Transmit)When this green LED is flashing, the bridge is transmitting packets to that network segment.

RCV (Receive)When this yellow LED is flashing, the bridge is receiving data packets from that network segment.

CP (Collision Present)When this red LED is flashing, a collision is occurring on that network segment.

POK (Port OK)When this green LED is on, the port has passed an Internal Loop Back Test and is ready for transmission

.

NOTE

You can access Port Performance Views through the Icon Subviews menu and by single-clicking the right mouse button to bring up the pop-up menu while in this Device View. The Device Menu allows you to access Configuration, Performance, Diagnostic, and Application Views from the Device View.

Page 20: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-5

SNMP NB30 Device View

SNMP NB30 Device ViewThis view represents the physical status of the SNMP NB30 Bridge device and provides menu access to the generic views. These generic views allow you to access network configuration information as well as traffic flow and error data for your bridge.

The Device View periodically polls the bridge model in the SpectroSERVER database to determine if any configuration changes have occurred. If a configuration change has occurred, the configuration is changed within the Device View to match the model in the SpectroSERVER database. Figure 2-3 provides and example of an SNMP Bridge NB-30 Device View.

Page 21: Cabletron SNMP Bridges MMG (9030368)

SNMP NB30 Device View

Device View2-6

Cabletron SNMP BridgesManagement Module Guide

Figure 2-3. Cabletron SNMP NB30 Bridge Device View

* File View Device MenuHelp?

Primary Landscape 0x00400000 - VNM Host - MIS of type HubCSINB30

NB-30ETHERNET/IEEE 802.3 BRIDGING UNITWITH REMOTE LANVIEW®

LINK OK

POK

CP

RCV

XMTPOWERSTAND BY

ROOT

FORWARDBROADCAST

ENETREMOTE

LINK OKYELLOWALARM CTS

REDALARM DM

POK POK

Page 22: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-7

SNMP NB30 Device View

SNMP NB30 LEDs

SNMP NB30 LEDs

The LEDs on the bridge front panels in the Device View are animated to reflect the state of the LEDs as of the last poll cycle. The LEDs turn on or off to match the bridge on the network. For detailed information on the LED definitions, and the operation of your bridge, refer to the documentation that accompanied your bridge. The following is a general definition of specific LEDs for the SNMP NB30 bridge model types.

POWERWhen this green LED is on, the bridge is receiving power.

STAND BYWhen this yellow LED is on, the bridge is in “STANDBY” mode and not capable of forwarding packets across the link.

Remote V.35 and RS449 Port

LINK OKWhen this green LED is on, the bridge has a valid receive clock from the DCE.

CTS (Clear To Send)When this yellow LED is on, the DCE is not conditioned to transmit data.

DM (Data Mode)When this red LED is on, the DCE is not in the data transfer mode.

POK (Port OK)When this green LED is on, the Remote Port has passed the Internal Loop Back Test and is ready for transmission. A proper transmit clock from the DCE must be present for this test to pass.

Remote DSX-1 Port

LINK OKWhen this green LED is on, a valid T1 signal is present.

YELLOW ALARMWhen this yellow LED on the local NB30 is on, the remote NB30 is in red alarm.

RED ALARMWhen this red LED on the local NB30 is on, it has lost synchronization with the remote NB30.

POK (Port OK)When this green LED is on, the Remote Port has passed the Internal Loop Back Test and is ready for transmission.

Page 23: Cabletron SNMP Bridges MMG (9030368)

SNMP NB30 Device ViewSNMP NB30 Front Panel Switches

Device View2-8

Cabletron SNMP BridgesManagement Module Guide

Ethernet Port

XMT (Transmit)When this green LED is flashing, the Ethernet side of the bridge is transmitting packets.

RCV (Receive)When this yellow LED is flashing, the Ethernet side of the bridge is receiving data packets.

CP (Collision Present)When this red LED is flashing, a collision is occurring on that Ethernet segment.

POK (Port OK)When this green LED is on, the Ethernet port has passed an Internal Loop Back Test and is ready for transmission.

SNMP NB30 Front Panel Switches

FORWARD BROADCASTWhen this switch is on (•), it allows the NB30 to forward broadcast messages.

ROOT

NOTE

You can access Port Performance Views (remote and local) through the Icon Subviews menu and by single-clicking the right mouse button to bring up the pop-up menu while in this Device View. The Device menu allows you to access Configuration, Performance, Diagnostic, and Application Views from the Device View.

NOTE

These switch settings are not depicted in the NB30 Device View, and must be seen by selecting Bridge Setup from the Configuration View.

Page 24: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-9

EFDMIM Device View

EFDMIM Device ViewThe EFDMIM is displayed in the Device View for a Cabletron hub. The hub Device View shows an actual representation of the hub with an EFDMIM installed in one of the slots. If the configuration changes (e.g., if an EFDMIM board is pulled or added to the hub), you see the corresponding change within this view. This change in the view occurs after the model’s next poll cycle.

This view represents the physical status of the EFDMIM installed in a Cabletron hub chassis and provides menu access to the EFDMIM generic views. These generic views allow you to access network configuration information, as well as traffic flow and error data for your EFDMIM.

Depending on the type of Cabletron hub containing the EFDMIM, the Device View appears slightly different. The Cabletron hub categories are as follows:

• IRM2, IRBM, or IRM3• IRM

The Device View periodically polls the hub model in the SpectroSERVER database to determine if any configuration changes have occurred. If a configuration change has occurred, the Device View changes as well to match the model in the SpectroSERVER database.

Accessing the Hub Logical/Physical Device View

You can access the Hub Logical or Physical Device View using one of the following methods (refer to Figure 2-4):

• Double-click on the Device View button of the hub icon. This opens the last device view accessed.

• Highlight the hub icon and select Device -> Logical orDevice -> Physical from the Icon Subviews menu.

Page 25: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Device ViewHub Logical Device View

Device View2-10

Cabletron SNMP BridgesManagement Module Guide

Figure 2-4. Accessing the Hub Device View

Hub Logical Device View

The IRM, IRM2, IRM3, and IRBM model types have available a Logical Device view that provides statistical information on each MIM it contains. Figure 2-5 provides an example of a Hub Logical Device View.

Double-click

Select Logical or Physical

CloseNavigateAlarmsPerformanceNotes...UtilitiesZoomConfigurationDiagnosticAcknowledge

Flash Green EnabledApplicationDeviceDevTop Logical

Physical

Page 26: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-11

EFDMIM Device View

Hub Logical Device View

Figure 2-5. Example of a Hub Logical Device View

A representation of an EFDMIM in this view presents the following information:

* File View Device MenuHelp?

Primary Landscape 0x00400000 - VNM Host - CTRON of type Hub_CSI_IRM3

IRBMSN

ONSTRCDNCRPO

ONRHNKDNCRPO

NS LK

AUI

ETHERNET

COMM

FOIRL

THRH

CONSOLE

MMAC

BRG

MT8 MIMSN

15

2

4

3

4

6

8

LNK

LNK

RCV

RCV

MT8 MIMSN

15

2

4

3

4

6

8

LNK

LNK

RCV

RCV

1

EFDMIM

ON

2 OFF

MMAC Device Panel

My OfficeLocation

Name IRM3

Logical Gauges Frames Gauge Mode Rates

Network Address

Device Type

System UpTime

132.177.118.24

Hub_CSI_IRM3

2+01:17:39

Page 27: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Device ViewHub Logical Device View

Device View2-12

Cabletron SNMP BridgesManagement Module Guide

Slot NumberThe number of the EFDMIM’s slot within the hub.

IP AddressThe IP address of the EFDMIM.

Board NameThe name of the EFDMIM.

Port NumberThe number of the port.

Port StatusThe current status of the port. The port status conditions are as follows:

STATUS COLOR CODENLNK (No Link) YellowON GreenOFF BlueSEG (Segmented) Red

Gauge Control Panel

The information displayed by the gauge located below the number and status of each port is controlled by the Gauge Control Panel. Access the Gauge Control Panel by clicking once on the hub’s logical representation, and selecting Icon Subviews from the File menu.

The Gauge Control Panel consists of three panels, as follows:

Gauge ModeThe Gauge Mode panel selections available are as follows:

RatesDisplays the selected statistic as a rate over a given time frame.

TotalsDisplays the total value of the selected statistic over the MIM’s up time.

PercentagesDisplays the selected statistic as a percentage of the total statistic for the MIM.

NOTE

When clicking on the hub’s representation, be sure not to click on one of the ports in the hub. Make sure that the entire hub board is highlighted before accessing the Icon Subviews menu.

Page 28: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-13

EFDMIM Device View

Hub Logical Device View

Gauge TypeThe Gauge Type panel selections are as follows:

NumericDisplays the numeric value of the selected statistic, on a field whose color corresponds to the attribute’s listing in the Selected Attribute panel. See Table 4-1 for a list of statistic colors.

LinearDisplays the value of the statistic as a bar graph, matching the color of the selected attribute. See Table 2-1 for a list of statistic colors.

Selected AttributeThe Selected Attribute panel selections are as follows:

Frame RateIndicates the amount of frames received or transmitted by the board or port.

Octet RateIndicates the amount of octets received or transmitted by the board or port.

Recv_Coll RateIndicates the amount of collisions received by the board or port.

Trans_Coll RateIndicates the amount of collisions generated by the board or port during transmission.

Error RateIndicates the amount of errors detected by the board or port.

Table 2-1. Gauge Selected Attribute Colors

Statistical Selection Gauge Color

Frame Rate Blue

Octet Rate Green

Recv_Coll Rate Light Orange

Trans_Coll Rate Light Orange

Error Rate Orange

Align_Errs Rate Lavender

CRC_Errs Rate Blue Green

Runts Rate Light Blue

Giants Rate Pink

OOW Rate Salmon

Page 29: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Device ViewHub Logical Device View

Device View2-14

Cabletron SNMP BridgesManagement Module Guide

Align_Errs RateIndicates the amount of misaligned packets detected by the board or port.

CRC_Errs RateIndicates the amount of packets received by the board or port with bad Cyclical Redundancy Checks (CRC).

Runts RateIndicates the amount of runt packets received by the board or port. A runt packet is one byte less than the standard Ethernet frame of 64 bytes not including preamble.

Giants RateIndicates the amount of giant packets received by the board or port. A giant packet exceeds 1518 bytes not including preamble.

OOW RateIndicates the amount of collisions out of the standard window (51.2µs) due to a network problem.

Make the desired selections in each of the windows, and click on the Apply button to apply the choices to the hub Device View. The view will update, however the selections will not be saved upon closing the Control Panel unless the Keep Settings button is first selected. Close the Control Panel by clicking on the Close button.

In addition, the hub Logical Device View displays a variety of information about the hub through a group of read-only dialog boxes at the top of the view, contained inside a box whose color matches the current contact status color of the hub.

Model NameThe user defined name of the hub model.

ContactIdentification and contact information of the person responsible for the hub.

DescriptionThe description of the hub containing the EFDMIM, which lists the device type as well as firmware version.

LocationThe physical location of the hub device.

Net AddressThe IP Address of the hub containing the EFDMIM.

System Up TimeThe time the hub has been active without failure, in the format: days+hours:minutes:seconds

ManufacturerThe manufacturer of the hub device.

Page 30: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-15

EFDMIM Device View

IRM2, IRBM, or IRM3 Hub Physical Device Views

Device TypeThe model type name of the hub containing the EFDMIM.

Serial NumberThe serial number of the hub device.

IRM2, IRBM, or IRM3 Hub Physical Device Views

The IRM2, IRBM, or IRM3 hub Physical Device Views present a variety of statistical information on each MIM installed in the hub chassis because of the high level monitoring point intelligence inherent in these hubs. The following sections describe the IRM2, IRBM, or IRM3 hub Device Views containing an EFDMIM.

MMAC Device Panel

The top portion of an IRM2, IRBM, or IRM3 hub Physical Device View containing the EFDMIM, displays the following information for the hub:

NameThe assigned or user-defined name for the hub containing the EFDMIM.

LocationThe physical location of the hub containing the EFDMIM.

Net AddressThe IP address of the hub containing the EFDMIM.

Device TypeThe model type name of the hub containing the EFDMIM.

System UpTimeThe time the hub has been active without failure displayed in the following format: days+hours:minutes:seconds

A condition status banner surrounding this information displays the condition status color for the hub containing the EFDMIM. In addition, the MMAC Device Panel provides two buttons that allow you to change the type of statistical information presented in the logical MIM horizontal bar gauges for either the EFDMIM or the entire hub, as described in the following section. Figure 2-6 shows an example of an IRM2, IRBM, or IRM3 MMAC Device Panel.

Page 31: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Device ViewEFDMIM Logical MIM Representation

Device View2-16

Cabletron SNMP BridgesManagement Module Guide

Figure 2-6. The IRM2, IRBM, or IRM3 MMAC Device Panel

EFDMIM Logical MIM Representation

The EFDMIM logical representation provides gauge and port information about the EFDMIM installed in the Cabletron hub instead of presenting a physical image. For information on a Device View physical MIM representation, refer to the section titled “EFDMIM Physical MIM Representation.” Refer to the section titled “Changing MIM Representations” for information on changing between logical and physical MIM representations. Figure 2-7 shows an example of a logical MIM representation.

An EFDMIM logical representation provides the following information about the board and the ports on the board:

Board NameThe name of the EFDMIM.

Port NumberThe number of the port.

Port StatusThe current status of the port. The port status conditions are as follows:

STATUS COLOR CODENLNK (No Link) YellowON GreenOFF BlueSEG (Segmented) Red

Two buttons are available from the MMAC Device Panel to change the statistical selections.

MMAC Device Panel

My OfficeLocation

Name IRBM Hub

Logical Gauges Frames Gauge Mode Percentage

Network Address

Device Type

System UpTime

132.177.118.24

Hub_CSI_IRBM

2+01:17:39

Page 32: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-17

EFDMIM Device View

EFDMIM Logical MIM Representation

Figure 2-7. Logical Representation of an EFDMIM in a Physical Device View

* File View Device MenuHelp?

Primary Landscape 0x00400000 - VNM Host - CTRON of type Hub_CSI_IRM3

IRBMSN

ONSTRCDNCRPO

ONRHNKDNCRPO

NS LK

AUI

ETHERNET

COMM

FOIRL

THRH

CONSOLE

MMAC

BRG

MT8 MIMSN

15

2

4

3

4

6

8

LNK

LNK

RCV

RCV

MT8 MIMSN

15

2

4

3

4

6

8

LNK

LNK

RCV

RCV

1

EFDMIM

ON

2 OFF

MMAC Device Panel

My OfficeLocation

Name IRM3

Logical Frames Gauge Mode Rates

Network Address

Device Type

System UpTime

132.177.118.24

Hub_CSI_IRM3

2+01:17:39

Page 33: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Device ViewEFDMIM Logical MIM Representation

Device View2-18

Cabletron SNMP BridgesManagement Module Guide

Logical Gauges

The Logical Gauges button accesses a menu that allows you to select the statistic represented by the horizontal bar gauges for the overall board or individual port on a MIM in logical MIM representation. The statistical selections are as follows:

FramesIndicates the amount of frames received or transmitted by the board or port.

BytesIndicates the amount of bytes received or transmitted by the board or port.

Recv_CollsIndicates the amount of collisions received by the board or port.

Trans_CollsIndicates the amount of collisions generated by the board or port during transmission.

Total_ErrorsIndicates the amount of errors detected by the board or port.

Align_ErrorsIndicates the amount of misaligned packets detected by the board or port.

CRC_ErrorsIndicates the amount of packets received by the board or port with bad Cyclical Redundancy Checks (CRC).

RuntsIndicates the amount of runt packets received by the board or port. A runt packet is one byte less than the standard Ethernet frame of 64 bytes not including preamble.

GiantsIndicates the amount of giant packets received by the board or port. A giant packet exceeds 1518 bytes not including preamble.

OutofWindowIndicates the amount of collisions out of the standard window (51.2µs) due to a network problem.

The horizontal bar gauge changes color depending on the statistic represented. Table 2-2 provides a list of the bar gauge statistic colors

Table 2-2. Horizontal Bar Gauge Statistic Colors

Statistical Selection Gauge Color

Frames Light blue

Bytes Blue

Recv_Colls Dark green

Page 34: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-19

EFDMIM Device View

EFDMIM Physical MIM Representation

Gauge Mode

The Gauge Mode button allows you to change the gauge representation of the selected statistic. The Gauge Mode field definitions are as follows:

PercentagesDisplays the selected statistic as a percentage of the total statistic for the MIM.

RatesDisplays the selected statistic as a rate over a given time frame.

EFDMIM Physical MIM Representation

The physical MIMs representation of the EFDMIM shows the board, its LEDs, and other physical features. Figure 2-8 shows an example of an IRM2, IRM3 or IRBM hub Device View in a physical MIM representation. Figure 2-9 shows a detailed example of the EFDMIM physical representation.

Trans_Colls Purple

Total_Errors Orange

Align_Errors Lavender

CRC_Errors Blue green

Runts Light purple

Giants Pink

OutofWindow Salmon

Table 2-2. Horizontal Bar Gauge Statistic Colors

Statistical Selection Gauge Color

Page 35: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Device ViewEFDMIM Physical MIM Representation

Device View2-20

Cabletron SNMP BridgesManagement Module Guide

Figure 2-8. Physical Representation of an EFDMIM in a Physical Device View

* File View Device MenuHelp?

Primary Landscape 0x00400000 - VNM Host - CTRON of type Hub_CSI_IRM3

EFDMIMSN

FDDI

MT8 MIMSN

15

2

4

3

4

6

8

LNK

LNK

RCV

RCV

MT8 MIMSN

15

2

4

3

4

6

8

LNK

LNK

RCV

RCV

MMAC Device Panel

My OfficeLocation

Name IRM3

Logical Gauges Frames Gauge Mode Rates

Network Address

Device Type

System UpTime

132.177.118.24

Hub_CSI_IRM3

2+01:17:39

STANDBY

SYSOK

POWER

CONSOLE

LINK

TXRX

WRAP

TOK

TXRXCOLPOK

FDDI

MMAC

CONFIG

FDDI A

FDDI B

BYPASS

ON NET

IRBMSN

ONSTRCDNCRPO

ONRHNKDNCRPO

NS LK

AUI

ETHERNET

COMM

FOIRL

THRH

CONSOLE

MMAC

BRG

Page 36: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-21

EFDMIM Device View

EFDMIM Physical MIM Representation

Figure 2-9. EFDMIM Device View Physical Representation

EFDMIM

SN

FDDI

STANDBY

SYSOK

POWER

CONSOLE

LINK

TXRX

WRAP

TOK

TXRXCOL

POK

FDDI

MMAC

CONFIG

FDDI A

FDDI B

BYPASS

ON NET

Page 37: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Device ViewEFDMIM Physical MIM Representation

Device View2-22

Cabletron SNMP BridgesManagement Module Guide

EFDMIM LEDs

This section provides an overview of the LEDs. For more detailed information, refer to the manual that came with your hardware. The EFDMIM LEDs are grouped into three categories: General, FDDI, and MMAC (Ethernet). During operation of the EFDMIM, the LANVIEW LEDs can be interpreted as follows:

General LEDs

POWERWhen lit, this green LED indicates that the power is on for the MMAC in which the EFDMIM is installed and the EFDMIM is receiving power.

SYSOKWhen lit, this green LED indicates that the EFDMIM internal self-test was completed successfully. This self-test is run each time you power on the unit.

STANDBYWhen lit, this yellow LED indicates that the bridge is in standby and no packets are being forwarded. OFF is the normal mode with packets being forwarded across the bridge.

FDDI Interface LEDs

TXWhen flashing, this green LED indicates that data is being sent out on the FDDI ring interface.

RXWhen flashing, this yellow LED indicates that data is being received from the FDDI ring interface.

WRAPWhen lit, this red LED indicates that the EFDMIM is in a wrap condition. OFF is the normal state.

TOKISDThis green LED flashes each time the EFDMIM places the token on the FDDI ring.

ON NETWhen lit, this green LED indicates that the EFDMIM’s FDDI interface is inserted into the FDDI ring network. OFF indicates that the EFDMIM is removed from the ring.

LINK A/BWhen lit, these green LEDs indicate that an optical signal is being detected.

Page 38: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-23

EFDMIM Device View

IRM Hub Physical Device View

MMAC (Ethernet) Interface LEDs

TXWhen flashing, this green LED indicates that data is being sent out on the Ethernet interface (MMAC backplane).

RXWhen flashing, this yellow LED indicates that data is being received from the Ethernet interface (MMAC backplane).

COLThis red LED flashes each time a packet collision occurs on the Ethernet/802.3 network.

POKWhen lit, this green LED indicates that the EFDMIM Ethernet port internal self-test was completed successfully. This self-test is run each time you power on the unit.

IRM Hub Physical Device View

The Physical Device View for an SNMP or Cabletron Proprietary IRM containing an SNMP Bridge device is similar to the Physical Device View for IRM2, IRM3, or IRBM hubs. The only difference is that the top portion of the IRM Physical Device View displays the MMAC Device Statistics Panel.

MMAC Device Statistics Panel

The MMAC Device Statistics Panel displays Frame Rate and Collision Rate information for the hub. Each rate is color-coded to correspond to the Multi-Attribute Line Graph. Figure 2-10 shows an example of an IRM MMAC Device Statistics Panel.

Three buttons are also available from the MMAC Device Statistics Panel to change the statistical presentation of the Multi-Attribute Line Graph or the logical MIM horizontal bar gauges, as follows:

The Log/Lin button toggles between a linear or logarithmic scale presentation of the graph.

Log/Lin

Page 39: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Device ViewIRM Hub Physical Device View

Device View2-24

Cabletron SNMP BridgesManagement Module Guide

Logical Gauges

The Logical Gauges button accesses a menu that allows you to select the statistic represented by the horizontal bar gauges for the overall board or individual port on a MIM in a logical MIM representation. The statistical selections are as follows:

FramesIndicates the amount of frames received or transmitted by the board or port

CollisionsIndicates the total amount of collisions detected by the board or port

The horizontal bar gauge changes color depending on the statistic represented, as shown in Table 2-3.

Gauge Mode

The Gauge Mode button allows you to change the gauge representation of the selected statistic, as follows:

PercentageDisplays the selected statistic as a percentage of the total statistic for the MIM.

RateDisplays the selected statistic as a rate over a given time frame.

Table 2-3. Horizontal Bar Gauge Statistic Colors

Statistical Selection Gauge Color

Frames Light blue

Collisions Yellow

Page 40: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-25

EFDMIM Device View

Configuring the EFDMIM in an IRM or IRBM Device View

Figure 2-10. The MMAC Device Statistics Panel

Configuring the EFDMIM in an IRM or IRBM Device View

To receive EFDMIM gauge and port information in the IRM or IRBM Device View logical representation and for the EFDMIM LEDs to appear “live” in the IRM or IRBM Device View physical representation, you must assign an IP address to the EFDMIM installed in the hub chassis as follows:

1. Move the mouse pointer onto the EFDMIM. Single-click the left mouse button to highlight the EFDMIM.

2. Select Icon Subviews from the View menu.

3. Select MIM Configuration View from the Icon Subviews menu to access the EFDMIM Configuration View.

4. Select Edit from the File menu in the EFDMIM Configuration View.

5. Enter the IP address of the EFDMIM device. If you have already created the EFDMIM as a stand alone icon, enter the same IP address here.

90

MMAC Device Statistics

Frame Rate

Collision Rate

Fri Jan 31 08:05:19 1996

1000

800

600

400

200

0

00:3:00:6:00:9:0

0

Lin

Logical Gauges Frames

Gauge Mode Percentage

NOTE

Cabletron recommends assigning a unique model name to the EFDMIM installed in the hub chassis to easily differentiate it from an independent EFDMIM icon (Bdg_CSI_EFDMIM) with the same assigned IP address.

Page 41: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Device ViewConfiguring the EFDMIM in an IRM2 or IRM3

Device View2-26

Cabletron SNMP BridgesManagement Module Guide

6. Select Save &Close from the File menu in the EFDMIM Configuration View.

7. A Pop-Up Window appears and prompts you whether to save the updated configuration information. Click OK.

8. Select Go Back from the View menu in the EFDMIM Configuration View to close this view.

Current EFDMIM gauge and port information in the IRM or IRBM Device View logical representation will now be provided. The EFDMIM LEDs in the IRM or IRBM Device View physical representation will now appear active.

Configuring the EFDMIM in an IRM2 or IRM3

To receive EFDMIM gauge and port information in the IRM2 or IRM3 Device View logical representation and for the EFDMIM LEDs to appear “live” in the IRM2 or IRM3 Device View physical representation, you must configure the EFDMIM installed in the hub chassis. The EFDMIM can only be configured in a Topology View. To configure the EFDMIM, execute the following procedures:

1. In the same Topology View level as the IRM2 or IRM3 with the installed EFDMIM, create a stand alone icon representing the EFDMIM.

2. In Edit mode, create a logical connection pipe between the stand alone EFDMIM icon and the IRM2 or IRM3 icon representing the hub with the installed EFDMIM. SPECTRUM automatically connects the EFDMIM to the hub’s internal port (CSIRptr Port).

3. In the EFDMIM DevTop view, connect the Off-Page Reference Icon representing the IRM2 or IRM3 containing the EFDMIM to the EFDMIM Ethernet port.

This completes the configuration procedure. Current EFDMIM gauge and port information in the IRM2 or IRM3 Device View logical representation is now provided. The EFDMIM LEDs in the IRM2 or IRM3 Device View physical representation will now appear active.

NOTE

Once the EFDMIM has been configured in the Topology View, the stand alone EFDMIM icon and the IRM2 or IRM3 icon containing the EFDMIM can be copied into a Location View.

Page 42: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-27

EFDMIM Device View

Copying the EFDMIM into a Location or Topology View

Copying the EFDMIM into a Location or Topology View

The EFDMIM installed in the hub chassis can be copied from the hub Device View and pasted as a stand-alone icon into a Location or Topology View, as follows:

1. Select Edit from the File menu.

2. Single-click on the EFDMIM to highlight it.

3. Select Copy from the Edit menu.

4. Navigate to the Location or Topology View.

5. Select Edit from the File menu.

6. Select Paste from the Edit menu.

The EFDMIM will now appear in the view as a stand-alone icon.

Page 43: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Device ViewChanging MIM Representations

Device View2-28

Cabletron SNMP BridgesManagement Module Guide

Changing MIM Representations

You can change the MIM representation of the entire hub or the MIM representation of the EFDMIM installed in the hub. This section describes several ways to change the representation of MIMs in a hub.

Changing MIM Representations on the Entire Hub

To change the MIM representation of the entire hub Device View, follow these steps:

1. In the hub’s Physical Device View, select the Device Menu menu option.

2. Click on either the Display Physical MIMs or Display Logical MIMs menu option. The entire hub changes to the selected MIM representation.

Changing MIM Representations Using the Menu Bar

To change the MIM representation of the EFDMIM using the menu bar, follow these steps:

1. In the hub’s Physical Device View, move the mouse pointer onto the EFDMIM. Single-click the left mouse button to highlight the EFDMIM.

2. Select the View menu, and select the Icon Subviews submenu. Select the Go Logical menu options from this submenu.

3. The EFDMIM changes its MIM representation. A selected single MIM appears to extend from the hub chassis.

NOTE

You must start in physical representation to use this toggle feature.

Page 44: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-29

EFDMIM Device View

Clearing Duplicate EFDMIM Address Alarms

Changing MIM Representations Using the Mouse

To change the MIM representation of the EFDMIM, using the mouse, follow these steps:

1. Move the mouse pointer onto the EFDMIM.

2. Double-click the left mouse button.

3. The EFDMIM changes its representation. A selected single MIM appears to extend from the hub chassis.

Clearing Duplicate EFDMIM Address Alarms

If you have previously created a stand alone EFDMIM icon and have created an IRM or IRBM hub icon and configured the EFDMIM installed in that hub through the hub Device View, a duplicate address alarm condition (yellow alarm) now exists in the hub icon containing the EFDMIM or the stand alone EFDMIM icon. This occurs because SPECTRUM views the independent EFDMIM icon and the EFDMIM installed in the hub icon as separate devices with the same assigned IP address. To alleviate this alarm condition, you must clear the duplicate alarm.

NOTE

You must start in physical representation to use this toggle feature.

NOTE

Make sure that the mouse pointer is not on top of or next to a gauge or port connector, otherwise a Port Performance View will open.

NOTE

Although yellow alarm conditions are minor alerts, Cabletron Systems recommends clearing these alarms when they occur.

Page 45: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Device ViewClearing Duplicate EFDMIM Address Alarms

Device View2-30

Cabletron SNMP BridgesManagement Module Guide

Two methods exist for clearing this yellow alarm condition, depending on the procedural order in which you created the independent EFDMIM icon and configured the EFDMIM in the IRM or IRBM hub Device View. The particular EFDMIM showing the duplicate IP address yellow alarm condition depends on which EFDMIM was created or configured first. The following sections describe the two possible ways of creating EFDMIMs and how to clear the resulting duplicate alarms.

Case #1

1. Create the independent EFDMIM (Bdg_CSI _EFDMIM) icon.

2. Create the IRM or IRBM hub icon that contains the EFDMIM.

3. Configure the EFDMIM in the hub Device View.

If you followed the previous procedure, you can clear the duplicate address alarm as follows:

1. Navigate to the hub Device View containing the EFDMIM.

2. Click on the EFDMIM to highlight it.

3. Select Icon Subviews from the View menu.

4. Select MIM Diagnostic View to access the EFDMIM Diagnostic View.

5. Select Alarms from the EFDMIM Diagnostic View. The Alarm View displays an alarm icon for the EFDMIM installed in the hub with a yellow alarm contact status color. The Symptom/Probable Cause box displays a DUPLICATE IP ADDRESS message.

6. Choose the Clear option from the Tools menu to clear the alarm. You can now exit from this view.

Case #2

1. Create the IRM or IRBM hub icon that contains the EFDMIM.

2. Configure the EFDMIM in the hub’s Device View.

3. Create the independent EFDMIM (Bdg_CSI_EFDMIM) icon.

4. If you followed the previous procedure, the EFDMIM (Bdg_CSI_EFDMIM) icon appears with a yellow alarm contact status in the Topology View. You can clear the duplicate address alarm as follows:

5. Click on the stand alone EFDMIM (Bdg_CSI_EFDMIM) icon.

6. Select Icon Subviews from the View menu.

Page 46: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Device View2-31

EFDMIM Device View

EFDMIM Generic Views

7. Select Diagnostic from the Icon Subviews menu to access the EFDMIM Diagnostic View.

8. Select Alarms from the EFDMIM Diagnostic View. The Alarm View displays two alarms for the independent EFDMIM icon each with a yellow alarm contact status color. The Symptom/Probable Cause box displays DUPLICATE IP ADDRESS and DUPLICATE-PHYSICAL ADDRESS messages respectively.

9. Choose the Clear option from the Actions menu to clear each of these alarms. You can now exit from this view.

EFDMIM Generic Views

To access the EFDMIM generic views (Configuration, Diagnostic, Application, and Performance) while in a hub Device View, follow these steps:

1. Single-click to select the EFDMIM physical or logical representation to highlight it.

2. Select Icon Subviews from the View menu.

3. Select the generic view of interest.

NOTE

The EFDMIM generic views can also be accessed from the independent EFDMIM icon (Bdg_CSI_EFDMIM) .

Page 47: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Device ViewEFDMIM Generic Views

Device View2-32

Cabletron SNMP BridgesManagement Module Guide

Page 48: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Application Views3-1

Chapter 3

Application Views

What is in this ChapterThis chapter describes the Application Views available for all Cabletron SNMP Bridges. The Application View contains network protocol traffic and database information for the Cabletron bridge device. Some of these attributes are external to SPECTRUM, since they are entered when the bridge device is configured. Other attributes are internal, since they are entered when the bridge device’s icon is created in the SpectroSERVER database. In the NB30 a filtering database is not maintained by the device on frames received through port 2 (the remote port). Consequently, filtering cannot be enabled or disabled for that port and all frames received through that port are automatically forwarded to port 1 (the local port).

Accessing the Application ViewYou can access the Application View using one of the following methods (refer to Figure 3-1):

• Double-click on the Application View label of the bridge icon.

• Highlight the bridge icon and select Application from the Icon Subviews menu.

Page 49: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Application Views3-2

Accessing the Application View

Figure 3-1. Accessing the Application View

Double-click

10

1

.1

.01

Select Application

CloseNavigateAlarmsPerformanceNotes...UtilitiesZoomConfigurationDiagnosticAcknowledge

Flash Green EnabledApplicationDeviceDevTop

Page 50: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Application Views3-3

NB20E, NB25E, and NB30 Application Views

NB20E, NB25E, and NB30 Application ViewsThe initial SNMP NB20E, SNMP NB25E, NB30 Application View provides the Model Name, Model Type, Network Address, HASPART Panel, and two buttons.

The Bridge Databases button accesses the SNMP Bridge Database View. This view provides information on the IEEE 802.1 Source Address Tables that are used to determine which frames will be forwarded through the SNMP bridge from one network segment to another. The following information is provided:

Model NameThe user-defined name of the bridge model.

Special DatabaseTable 3-1 lists the information provided by this area of the SNMP Bridge Database View.

Bridge Databases

Table 3-1. Bridge Database View Special Database Information Fields

Field Description

Number of Filters The current number of filters in the Special Database.

Max Number of Filters The maximum number of filters allowed in the Special Database.

Page 51: Cabletron SNMP Bridges MMG (9030368)

NB20E, NB25E, and NB30 Application Views

Application Views3-4

Cabletron SNMP BridgesManagement Module Guide

Acquired DatabaseTable 3-2 lists the information provided by this area of the SNMP Bridge Database View.

Table 3-2. Bridge Database View Acquired Database Information Fields

Field Description

Total Entries The total number of Dynamic or Static entries in the Acquired Database.

Maximum Entries The maximum number of Dynamic or Static entries allowed in the Acquired Database.

Static Entries The number of addresses added to the Acquired Database by you or the network manager.

Static Entry Age Lmt (Not Available for NB30)

The length of time allowed for a Static entry in the Acquired Database to be inactive before it is dropped from the database. This time is fixed at zero (0) as Static entries do not age-out.

Dynamic Entries The number of Dynamic entries that have been accumulated in the acquired database through the bridge’s learning process.

Dynamic Entry Age Lmt The length of time allowed for a Dynamic entry in the Acquired Database to be inactive before it is dropped from the database. A time range of 10 - 1,000,000 seconds can be specified.

Database Entries Erase (set to zero) all Dynamic or Static entries in the acquired database (except for the 16 [17 for the NB30] permanent Static entries) by clicking the Erase button.

Page 52: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Application Views3-5

NB20E, NB25E, and NB30 Application Views

Permanent DatabaseTable 3-3 lists the information provided by this area of the SNMP Bridge Database View.

Three additional buttons are available to access the SNMP Bridge database tables, as follows:

The Permanent Database Table button accesses the SNMP Bridge Permanent Database Table. The SNMP Bridge Permanent Database Table displays addresses that remain in the Source Address Table when the system is shut down. For the NB30, there is no Port2 Out column supported, and Port1 Out is named Filtering. The Add New Database Entry area of the Permanent Database Table allows you to enter a new Static hexadecimal Ethernet address into the Permanent Database. A Select Filtering button is also provided that accesses an SNMP Bridge Filter Selection View. Table 3-4 lists the filtering options for the Static address.

Table 3-3. Bridge Database View Permanent Database Information Fields

Field Description

Current Entries The number of Static entries currently recorded in the bridge’s Permanent Database.

Maximum Entries The maximum number of Static entries allowed in the Permanent Database.

Database Entries Erase (set to zero) all Static entries in the permanent database (except for the 16 [17 for the NB30] permanent Static entries) by clicking the Erase button. For the NB30 this also erases the entries in the Acquired Database.

Permanent Database Table

Page 53: Cabletron SNMP Bridges MMG (9030368)

NB20E, NB25E, and NB30 Application Views

Application Views3-6

Cabletron SNMP BridgesManagement Module Guide

Double-clicking on a column entry accesses an entry-specific Permanent Database Information View. Table 3-5 lists the information provided by this view.

Table 3-4. Permanent Database Static Address Filtering Options

Option Description

Prt1=Filter/Prt2=Filter (Not Available for NB30)

Add an entry to the Permanent Database Table to filter packets entering ports 1 and 2 if those packets are destined for the specified address.

Prt1=Filter/Prt2=Relay_Prt1

Add an entry to the Permanent Database Table to filter packets entering port 1 and forward packets entering port 2 if those packets are destined for the specified address. In the NB30 a filtering database is not maintained by the device on frames received through port 2 (the remote port). Consequently, filtering cannot be enabled or disabled for that port and all frames received through that port are automatically forwarded to port 1 (the local port).

Prt1=Relay_Prt2/Prt2=Relay_Prt1

Add an entry to the Permanent Database Table to forward packets entering ports 1 and 2 if those packets are destined for the specified address. In the NB30 a filtering database is not maintained by the device on frames received through port 2 (the remote port). Consequently, filtering cannot be enabled or disabled for that port and all frames received through that port are automatically forwarded to port 1 (the local port).

Prt1=Filter/Prt2=Filter (Not Available for NB30)

Add an entry to the Permanent Database Table to forward packets entering port 1 and filter packets entering port 2 if those packets are destined for the specified address.

Permanent Entry (NB30 only)

Delete the selected entry from the Permanent Database Table.

NOTE

Selecting a filtering option from this view, toggles to the next the filtering option and highlights it. The initial filter selected is the actual option that is used.

Page 54: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Application Views3-7

NB20E, NB25E, and NB30 Application Views

The Acquired Database Table button accesses the SNMP Bridge Acquired Database Table. The SNMP Bridge Acquired Database Table displays address entries that do not remain in the Source Address Table when the system is shut down. These entries can either be Static (entered by you) or Dynamic (added to the table through the bridge’s learning process). For the NB30, there is no Port2 Out column supported, and Port1 Out is named Filtering. The Add New Database Entry area of the Acquired Database Table allows you to enter a new Static Ethernet address into the Acquired Database. A Select Filtering button is also provided that accesses an SNMP Bridge Filter Selection View. Table 3-6 provides a list of the filtering options for the Static address.

Double-clicking on a column entry in the Acquired Database Table accesses an entry-specific Acquired Database Information View. Table 3-7 lists the information provided by this view.

Table 3-5. Permanent Database Information View Fields

Field Description

Model Name The user-defined name of the bridge model.

Source Address The source address of the entry selected.

Entry Type The entry type: Static or Dynamic. Permanent Database entries are always Static.

Port1 Out(Filtering for NB30)

The outbound port for packets entering port 1. A read-only indicator button displays the port’s filtering designation (Filter or Relay).

Port2 Out(Not Available for NB30)

The outbound port for packets entering port 2. A read-only indicator button displays the port’s filtering designation (Filter or Relay).

Permanent Entry Allows you to delete this address from the Permanent Database Table by clicking on the Delete button.

Acquired Database Table

Page 55: Cabletron SNMP Bridges MMG (9030368)

NB20E, NB25E, and NB30 Application Views

Application Views3-8

Cabletron SNMP BridgesManagement Module Guide

Table 3-6. Acquired Database Table Static Address Filter Options

Field Description

Prt1=Filter/Prt2=Filter(Not Available for NB30)

Add an entry to the Acquired Database Table to filter packets entering ports 1 and 2 if those packets are destined for the specified address.

Prt1=Filter/Prt2=Relay_Prt1 Add an entry to the Acquired Database Table to filter packets entering port 1 and forward packets entering port 2 if those packets are destined for the specified address. In the NB30 a filtering database is not maintained by the device on frames received through port 2 (the remote port). Consequently, filtering cannot be enabled or disabled for that port and all frames received through that port are automatically forwarded to port 1 (the local port).

Prt1=Relay_Prt2/Prt2=Relay_Prt1 Add an entry to the Acquired Database Table to forward packets entering ports 1 and 2 if those packets are destined for the specified address. In the NB30 a filtering database is not maintained by the device on frames received through port 2 (the remote port). Consequently, filtering cannot be enabled or disabled for that port and all frames received through that port are automatically forwarded to port 1 (the local port).

Prt1=Filter/Prt2=Filter(Not Available for NB30)

Add an entry to the Acquired Database Table to forward packets entering port 1 and filter packets entering port 2 if those packets are destined for the specified address.

Acquired Entry (NB30 only) Delete the selected entry from the Acquired Database Table.

NOTE

Selecting a filtering option from this view, toggles to the next filtering option and highlights it. The initial filter selected is the actual option that is used.

Page 56: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Application Views3-9

NB20E, NB25E, and NB30 Application Views

The Special Database Table button accesses the SNMP Bridge Special Database Filter Table. The SNMP Bridge Special Database Filter Table displays filtering information for forwarding packets through the bridge from one network segment to another. For the NB30, there is no Port2 Out column supported, and Port1 Out is named Port 1. Table 3-8 lists the information provided by the Add New Database Entry area of the Special Database Filter Table. An Add an Entry button is also provided that accesses an SNMP Bridge Add an Entry View. This view allows you to select filtering options for a Static address. Table 3-9 provides a list of the view’s filtering options.

Table 3-7. Acquired Database Information View Fields

Field Description

Model Name The user-defined name of the bridge model.

Source Address The source address of the entry selected.

Entry Type The entry type: Static or Dynamic.

Port1 Out (Filtering for NB30)

The outbound port for packets entering port 1. A read-only indicator button displays the port’s filtering designation (Filter or Relay).

Port2 Out(Not Available for NB30)

The outbound port for packets entering port 2. A read-only indicator button displays the port’s filtering designation (Filter or Relay).

Acquired Entry Allows you to delete this address from the Acquired Database Table by clicking on the Delete button

Special Database Table

Table 3-8. Special Database New Database Information

Field Description

Next Available Filter The number of the next available filter that can be added to the Special Database Filter Table. This field will appear red-boxed if the database is full and no more filters can be added. For the NB30 the next available filter will be set to 255 if the database is full, and the field is not boxed in red.

Set to Next Available Filter

Allows you to specify the next available filter to be added to the Special Database Filter Table.

Page 57: Cabletron SNMP Bridges MMG (9030368)

NB20E, NB25E, and NB30 Application Views

Application Views3-10

Cabletron SNMP BridgesManagement Module Guide

Double-clicking on a column entry from the Special Database Filter Table accesses a filter-specific Special Database Information View. A Delete Filter button is provided that accesses the Delete Special Database Filter View. This filter can be removed by clicking on the Delete button in this view.

The System button accesses the SNMP System Group View. This view provides the following information:

System DescriptorA textual description of the SNMP Bridge. This description includes the name and version of the hardware type, the software operating system, and the networking software.

System UpTimeThe time, in days+hours:minutes:seconds, since the SNMP Bridge’s network management software was last reinitialized.

System Object IDThe Structure of Management Information (SMI) identification of the network management subsystem contained in the SNMP Bridge.

Table 3-9. Special Database Add an Entry View Options

Field Description

Port 1 Filter/Relay Set port 1 to filter or forward packets.

Port 2 Filter/Relay (Not Available for NB30)

Set port 2 to filter or forward packets.

Source Address Set the Special Database to filter packets with a specific source address.

Destination Address Set the Special Database to filter packets with a specific destination address.

Filter by Type Field (Frame Type for NB30)

Set the Special Database to filter packets with a specific type field.

Filter by Data Field (Data Field for NB30)

Set the Special Database to filter packets based on the first sixteen bits of data in the packet.

Enable/Disable Filter (Filter Status for NB30)

Allows you to Enable or Disable the selected filtering.

System

Page 58: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Application Views3-11

EFDMIM Application View

HASPART Panel

HASPART Panel

The HASPART panel provides different entries for the different bridges modeled. For the SNMP NB20E and SNMP NB25E only one entry choice is available. Double-clicking on the Prt_Bdg_SEnet # entry accesses an interface specific Ethernet Port Performance View. For the NB30 there are two valid entry choices. Double-clicking on the CSIBrdg_LPort $ entry accesses the Ethernet Port Performance View. Double-clicking on the CSIBrdgPrtV35 $ (this could also be CSIBrdgPrtDSX depending on the port type) accesses an interface specific Remote Port Performance View. The section titled “Port Performance View” describes the Ethernet Port Performance View and the Remote Port Performance View.

EFDMIM Application ViewThe initial EFDMIM Application View provides the Model Name, Model Type, Network Address, Ring Table, and the HASPART Panel.

Ring Table

The Ring Table provides an ordered list and description of each node on the FDDI Ring and provides the following information:

MAC AddressThe EFDMIM FDDI MAC address.

Up NeighborA 6 octet canonical representation of the upstream neighbor’s address. The upstream neighbor is the last node on the ring to receive the FDDI token before this node.

A read-only indicator button displaying if the node is functioning as a station or a concentrator.

Ring MACSThe number of devices on the FDDI Ring.

NonMasterThe total number of A-Ports, B-Ports, and S-Ports on the FDDI Ring.

Master PhysThe number of master ports on this FDDI Ring (from 0 to 255).

Ring TopologyThe current state of the FDDI Ring. Table 3-10 shows the possible states.

Node Class

Page 59: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Application ViewRing Table

Application Views3-12

Cabletron SNMP BridgesManagement Module Guide

Ring DuplicateIndicates duplicate address information for the EFDMIM. Table 3-11 shows the possible indications.

Table 3-10. Possible FDDI Ring States

State Description

Isolated The EFDMIM is not attached to the ring.

Non-Op The EFDMIM is attempting to enter the ring.

Ring-Op The ring is operational.

Detect The claim/beacon process of the FDDI ring protocol has exceeded 1 second. This indicates a potential problem.

Non-Op-Dup The ring failed to complete the claim/beacon process because a duplicate FDDI address has been detected.

Ring-Op-Dup The ring is operational but a duplicate FDDI address has been detected.

Directed The claim/beacon process did not complete within 9 seconds. The EFDMIM is now sending directed beacons to indicate a problem.

Trace A problem has been detected with the station or its upstream neighbor. A trace is being sent to notify the upstream neighbor of the problem. The EFDMIM and all stations between the EFDMIM and its upstream neighbor will run self-tests.

Table 3-11. Possible EFDMIM Duplicate Address Indications

Indicator Description

My Duplicate The EFDMIM has determined that its MAC address is the same as another node on the FDDI Ring.

UNA Duplicate The EFDMIM’s upstream neighbor has determined that its MAC address is the same as another node on the ring.

Page 60: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Application Views3-13

EFDMIM Application View

HASPART Panel

HASPART Panel

The EFD_If_Port # button available from the HASPART panel accesses an interface specific EFDMIM Port Performance View. The EFDMIM Port Performance View is described in the section titled “Port Performance View.”

Page 61: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Application ViewHASPART Panel

Application Views3-14

Cabletron SNMP BridgesManagement Module Guide

Page 62: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Configuration Views4-1

Chapter 4

Configuration Views

What is in this ChapterThis chapter describes the Configuration Views available for the Cabletron SNMP Bridges. The Configuration View contains more detailed network configuration information for the Cabletron SNMP Bridge. Some of these configuration attributes are external and some internal. This view also allows you to configure the polling cycles to the bridge device model in the SpectroSERVER database.

Accessing the Configuration ViewYou can access the Configuration View using one of the following methods (refer to Figure 4-1):

• Double-click on the Configuration View label of the bridge icon.

• Highlight the bridge icon and select Configuration from the Icon Subviews menu.

Page 63: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Configuration Views4-2

Accessing the Configuration View

Figure 4-1. Accessing the Configuration ViewDouble-click

10

1

.1

.01

Select Configuration

CloseNavigateAlarmsPerformanceNotes...UtilitiesZoomConfigurationDiagnosticAcknowledge

Flash Green EnabledApplicationDeviceDevTop

Page 64: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Configuration Views4-3

NB20E, NB25E, and NB30 Configuration Views

Model Configuration

NB20E, NB25E, and NB30 Configuration Views

Model Configuration

This area of the SNMP Bridge Configuration View provides the following information:

Model NameThe user-defined name of the bridge model.

Network AddressThe Internet Protocol (IP) address of the SNMP Bridge.

Community NameThe Community Name that has been assigned locally to this SNMP Bridge.

Security StringThe SNMP Bridge’s assigned Security String. (Refer to User Security and User Maintenance for details on setting up security in SPECTRUM.)

Polling IntervalThe time, in seconds, between SpectroSERVER polls of the network for a specific model.

Poll Log RatioThe number of SpectroSERVER polls of a device that occur prior to logging the poll results in the database.

Polling StatusThis True/False button allows an administrator to disable SpectroSERVER polls of a device by setting Polling Status to False and selecting Save All Changes from the File menu. This is useful to disable rollup conditions for minor network events such as a workstation power-down.

Device Configuration

This area of the SNMP Bridge Configuration View provides the following information:

Bridge NameThe user-defined name of the bridge. The default is ETHERNET BRIDGE for the NB20E and NB25E. The default is CABLETRON REMOTE for the NB30.

Bridge TypeThe type of bridge (e.g., NB20E, NB25E, or NB30).

Page 65: Cabletron SNMP Bridges MMG (9030368)

NB20E, NB25E, and NB30 Configuration ViewsDevice Configuration

Configuration Views4-4

Cabletron SNMP BridgesManagement Module Guide

Bridge LocationThe user-defined name to indicate the location of the bridge on the network. The default location is LOCAL.

Firmware VersionThe release version of the firmware installed in the bridge.

Number of Ports The number of ports on the bridge.

The SNMP Bridge Configuration View also provides six buttons:

The Bridge/Root Information button accesses the Bridge/Root Information View. This view provides the following information:

Model NameThe user-defined name of the bridge model.

Root Bridge IDThe Ethernet address of the bridge that is currently functioning as the root bridge.

Root PortThe number of the port that provides the lowest cost path to the root bridge.

Root CostThe value or cost of the data path from the bridge to the root bridge.

Root Brdg Max AgeThe maximum time a Bridge Protocol Data Unit (BPDU) can exist before it is discarded if a bridge is the root or is attempting to become the root. A time range of 6 to 40 seconds can be specified. The default is 20 seconds.

The Additional Bridge Information button accesses the Additional Bridge Information View. This view provides the following information:

Model NameThe user-defined name of the bridge model.

Bridge PriorityThe part of the bridge ID that contains the identifier used in the spanning tree for priority comparisons. An allowed range of 0 through FFFF can be specified. The default is 8000.

Hold TimeThe minimum time period elapsing between the transmission of configuration BPDUs through a given bridge port.

Protocol Max AgeThe maximum age of received protocol information before it is discarded.

Bridge/Root Information

Additional Bridge Information

Page 66: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Configuration Views4-5

NB20E, NB25E, and NB30 Configuration Views

Device Configuration

Trap Type Obj ID (Not Available for NB30)Contains the object identifier of the first VarBinding in the last trap generated by the bridge.

The Bridge Setup Information button accesses the Setup Information View. This view is different for the NB20E, NB25E, and NB30. The information supplied for the different model types is shown below:

NB20E and NB25E

Model NameThe user-defined name of the bridge model.

Bridge IDThe bridge priority plus the Ethernet address of the bridge.

Switch SettingsThe current switch settings read from the bridge hardware.

Number of RestartsThe number of times the bridge has been powered up or restarted.

Type of FilteringThe type of filtering to be performed by the bridge. The default is IEEE 802.1.

STA ProtocolThe spanning tree algorithm under which the bridge is operating. Selections include: 802.1 compliant spanning tree algorithm environment (802.1), DEC LAN Bridge 100 environment (DEC), and without spanning tree algorithm enabled (None). The default is 802.1.

NB30

Model NameThe user-defined name of the bridge model.

Bridge IDThe bridge priority plus the Ethernet address of the bridge.

Firmware VersionThe firmware version currently loaded on the NB30 bridge.

Number of RestartsThe number of times the bridge has been powered up or restarted.

Type of FilteringThe type of filtering to be performed by the bridge. The default is IEEE_802.1.

Bridge Setup Information

Page 67: Cabletron SNMP Bridges MMG (9030368)

NB20E, NB25E, and NB30 Configuration ViewsDevice Configuration

Configuration Views4-6

Cabletron SNMP BridgesManagement Module Guide

STA ProtocolThe spanning tree algorithm under which the bridge is operating. Selections include: 802.1 compliant spanning tree algorithm environment (802.1), DEC LAN Bridge 100 environment (DEC), and without spanning tree algorithm enabled (None). The default is 802.1.

The Device Switch Settings section of the Bridge Setup Information View has six additional read-only parameters. Table 4-1 provides a list of the parameters.

The Topology Information button accesses the Topology Information View. This view provides the following information:

Model NameThe user-defined name of the bridge model.

Time Topology ChangeThe time, in seconds, that has elapsed since the bridge’s Topology Change Flag last recorded the value of a topology change.

Table 4-1. Bridge Setup Information View Parameters

Field Description

Broadcasts Indicates whether the bridge will forward Broadcast packets across the wide area transmission link. Filtered means that packets will not be forwarded, Forwarded means that they will be forwarded.

ROOT Indicates whether the bridge has the Root Switch enabled or disabled. OFF means the Root Switch is disabled, ON means that it is enabled.

Switch 1 In the Up position this switch indicates the bridge is configured to Data Mode Control Signal Switch, The Down position indicates the bridge is configured to T1 Timing Mode Switch.

Switch 2 In the Up position this switch indicates that the Spanning Tree Algorithm Switch is Enabled. The Down position indicates that the switch is Disabled.

Switch 3 This switch selects the T1 frame format. In the Up position this switch indicates the bridge is configured to ESF frame format, the Down position selects the D4 frame format. Both bridges must use the same frame format.

Switch 4 This switch is not used by the NB30 bridge.

Topology Information

Page 68: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Configuration Views4-7

NB20E, NB25E, and NB30 Configuration Views

Device Configuration

Topology ChangeIndicates if a bridge Topology change is in progress.

Topology Change CountThe number of times the bridge’s Topology Change Flag has been changed since the bridge was powered up or initialized.

The Fwd Dly & Hello Information button accesses the Forward Delay & Hello Information View. This view provides the following information:

Model NameThe user-defined name of the bridge model.

Forward Delay ParmThe value of the forward delay parameters when the bridge is the root or attempting to become root. A time range of 4 to 30 seconds can be specified. The default is 15.

Forward DelayThe time spent in the LISTENING state while moving from the BLOCKING state to the LISTENING state, or the time spent in the LEARNING state while moving from the LISTENING state to the FORWARDING state.

Hello Time ParmThe value of the Hello Time parameter when the bridge is the root or is attempting to become the root. A time range of 1 to 10 seconds can be specified. The default is 2 seconds.

Hello TimeIndicates, in seconds, the length of time the root bridge or bridge attempting to become the root waits before resending configuration BPDUs.

The Control button accesses the SNMP Bridge Control View. This view provides the following information:

Current Bridge StatusThe status of the bridge (ON-LINE, STAND BY, or DISABLED).

Enable or disable the bridge by toggling this button.

Fwd Dly & Hello Information

Control

Bridge Status

Page 69: Cabletron SNMP Bridges MMG (9030368)

NB20E, NB25E, and NB30 Configuration ViewsEFDMIM Configuration View

Configuration Views4-8

Cabletron SNMP BridgesManagement Module Guide

Force the bridge to undergo a software reset by clicking on this button.

Restore the bridge settings to their default values by clicking on this button. (Default settings for NB30).

Reset all device maintained counters by clicking on this button (NB30 only).

EFDMIM Configuration View

The EFDMIM Configuration View is divided into two sections: Model Configuration and Device Configuration.

Model Configuration

This area of the EFDMIM Configuration View provides the following information:

Model NameThe user-defined name of the bridge model.

Network AddressThe Internet Protocol (IP) address of the EFDMIM.

Community NameThe Community Name that has been assigned locally to this EFDMIM.

Security StringThe EFDMIM assigned Security String. (Refer to User Security and User Maintenance for details on setting up security in SPECTRUM.)

Polling IntervalThe time, in seconds, between SpectroSERVER polls of the network for a specific model.

Poll Log RatioThe number of SpectroSERVER polls of a device that occur prior to logging the poll results in the database.

Bridge Restart

Bridge Settings

Counters

Page 70: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Configuration Views4-9

NB20E, NB25E, and NB30 Configuration Views

EFDMIM Configuration View

This button allows an administrator to disable SpectroSERVER polls of a device by setting Polling Status to FALSE and selecting Save All Changes from the File menu. This is useful to disable rollup conditions for minor network events such as a workstation power-down.

Device Configuration

This area of the EFDMIM Configuration View provides the following information:

Bridge NameThe user-defined name of the bridge. The default is Cabletron Enet-FDDI Bridge.

Firmware VersionThe release version of the firmware installed in the bridge.

Bridge AddressThe factory-set address for the EFDMIM displayed in Ethernet and FDDI formats.

Bridge LocationThe user-defined name to indicate the location of the bridge on the network. The default location is LOCAL.

Bridge UptimeThe number of seconds since the EFDMIM was last reset or initialized.

Ring UptimeThe number of seconds since the most recent FDDI Ring oscillation. This field resets to zero when the FDDI Ring is non-operational.

Two additional buttons are available from the EFDMIM Configuration View.

The Additional Configuration button accesses an additional EFDMIM Configuration View, which provides the following information:

Model NameThe user-defined name of the bridge model.

Network AddressThe Internet Protocol (IP) address of the EFDMIM.

Polling Status

Additional Configuration

Page 71: Cabletron SNMP Bridges MMG (9030368)

NB20E, NB25E, and NB30 Configuration ViewsEFDMIM Configuration View

Configuration Views4-10

Cabletron SNMP BridgesManagement Module Guide

CFM StateThe EFDMIM current Configuration Management state. This indicates the current physical connections to the EFDMIM. Table 6-13 shows possible CFM states.

RMT StateThe current state of the ring. Table 6-14 shows possible RMT states.

A read-only indicator button displaying whether the station has an optical bypass switch (TRUE or FALSE).

A read-only indicator button displaying whether the optical bypass switch is stuck (TRUE or FALSE).

A read-only indicator button displaying whether the EFDMIM is an encapsulating bridge (using FDDI as a backbone only) or a translation bridge (translating packets into FDDI format).

OscillationsThe number of times the claim/beacon process has completed since the last power-up. The counter does not accept a reset command.

Downstream MACThe address of the EFDMIM’s downstream neighbor in canonical format.

Bypass Attached

Bypass Stuck

Bridge Mode

Table 4-2. Possible EFDMIM CFM States

State Description

Isolated Both PHY-A and PHY-B are disconnected from the ring. There are no connections at either the A or B FDDI port.

Wrap-A PHY-A is wrapped via the MAC (from PHY-A/Primary In to MAC to Secondary Out/PHY-A) and PHY-B is disconnected.

Wrap-B PHY-B is wrapped via the MAC (from PHY-B/Secondary In to MAC to Primary Out/PHY-B) and PHY-A is disconnected.

Wrap-AB PHY-B is connected to the MAC (from PHY-B/Secondary In to MAC to Primary Out/PHY-B) and PHY-A is wrapped (connecting Primary In to Secondary Out), isolating PHY-A from the MAC.

Page 72: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Configuration Views4-11

NB20E, NB25E, and NB30 Configuration Views

EFDMIM Configuration View

Through-A Indicates that the primary ring is connected to the MAC (from PHY-A/Primary In to MAC to Primary Out/PHY-B). The secondary ring is isolated from the MAC (from PHY-B/Secondary In to PHY-A/Secondary Out).

Through-B Indicates that the secondary ring is connected to the MAC (from PHY-B/Secondary In to MAC to Secondary Out/PHY-A). The primary ring is isolated from the MAC (from PHY-A/Primary In to PHY-B/Primary Out).

Table 4-3. Possible EFDMIM RMT States

State Description

Isolated The EFDMIM is not attached to the ring.

Non-Op The EFDMIM is attempting to enter the ring.

Ring-Op The ring is operational.

Detect The claim/beacon process of the FDDI ring protocol has exceeded 1 second. This indicates a potential problem.

Non-Op-Dup The ring failed to complete the claim/beacon process because a duplicate FDDI address has been detected.

Ring-Op-Dup The ring is operational but a duplicate FDDI address has been detected.

Directed The claim/beacon process did not complete within 9 seconds. The EFDMIM is now sending directed beacons to indicate a problem.

Trace A problem has been detected with the station or its upstream neighbor. A trace is being sent to notify the upstream neighbor of the problem. The EFDMIM and all stations between the EFDMIM and its upstream neighbor will run self-tests.

Table 4-2. Possible EFDMIM CFM States (Continued)

State Description

Page 73: Cabletron SNMP Bridges MMG (9030368)

NB20E, NB25E, and NB30 Configuration ViewsEFDMIM Configuration View

Configuration Views4-12

Cabletron SNMP BridgesManagement Module Guide

Switch SettingsIn addition, the Switch Settings area of the additional EFDMIM Configuration View provides a table containing a series of read-only indicator buttons that (if they appear depressed) indicate which jumper settings are enabled on the EFDMIM board. Table 6-15 provides a list of the jumper setting information fields.

The Control button accesses the EFDMIM Control View, providing the Model Name, Network Address, and the following information:

Bridge StatusThe status of the EFDMIM (ON-LINE, STAND BY, or DISABLED).

Enable or disable the EFDMIM by toggling this button.

Table 4-4. Configuration View Jumper Setting Fields

Field Description

Root Not depressed indicates the spanning tree root is selected.

ForwardBroad Not depressed indicates packets are being forwarded not filtered.

SpannTree Not depressed indicates spanning tree facilities are enabled.

BPDU Not depressed indicates the spanning tree is using the IEEE 802.1 Bridge Protocol Data Unit (BPDU) rather than the DEC BPDU.

Bypass Not depressed indicates there is an optical bypass physically attached to the EFDMIM.

Ring Not depressed indicates the EFDMIM should attach to the primary FDDI Ring rather than the secondary FDDI Ring.

Diagnostics Not depressed indicates the EFDMIM is in its normal operating mode and not running diagnostic self-tests.

Mode Not depressed indicates the EFDMIM is an encapsulating bridge (uses FDDI as a backbone between two Ethernet segments) rather than a translation bridge (communicates from Ethernet to Ethernet or Ethernet to FDDI).

Control

Bridge Status Control

Page 74: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Configuration Views4-13

NB20E, NB25E, and NB30 Configuration Views

EFDMIM Configuration View

Force the EFDMIM to reset its counters by clicking on this button. The EFDMIM resets all counters except the following:

FDDI Frame CountFDDI Error CountFDDI Lost CountFDDI Ring Oscillations

Counters

Page 75: Cabletron SNMP Bridges MMG (9030368)

NB20E, NB25E, and NB30 Configuration ViewsEFDMIM Configuration View

Configuration Views4-14

Cabletron SNMP BridgesManagement Module Guide

Page 76: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Diagnostic Views5-1

Chapter 5

Diagnostic Views

What is in this ChapterThis chapter describes the Diagnostic View available for Cabletron SNMP Bridges. The Diagnostic View provides a breakdown of network errors gathered by the SNMP Bridge or EFDMIM on a network segment. Each error attribute is summarized over two intervals: total interval since first poll and rate interval between polls. Buttons allow you to select a graphical representation for the error attributes, and to bring up the Event and Alarm Log Views.

Accessing the Diagnostic ViewYou can access the Diagnostic View using one of the following methods (refer to Figure 5-1):

• Double-click on the Diagnostic View label of the bridge icon.

• Highlight the bridge icon and select Diagnostic from the Icon Subviews menu.

Page 77: Cabletron SNMP Bridges MMG (9030368)

SNMP NB20E, SNMP NB25E and NB30 Diagnostic View

Diagnostic Views5-2

Cabletron SNMP BridgesManagement Module Guide

Figure 5-1. Accessing the Diagnostic View

SNMP NB20E, SNMP NB25E and NB30 Diagnostic View

The initial SNMP Bridge Diagnostic View displays the following information:

Model NameThe user-defined name of the bridge model.

Bridge NameThe user-defined name of the bridge. The default is ETHERNET BRIDGE (CABLETRON REMOTE BRIDGE for the NB30).

Bridge TypeThe type of bridge (e.g., NB20E, NB25E, or NB30).

StatusThe status of the bridge (ON-LINE, STAND BY, or DISABLED).

Double-click

10

1

.1

.01

Select Diagnostic

CloseNavigateAlarmsPerformanceNotes...UtilitiesZoomConfigurationDiagnosticAcknowledge

Flash Green EnabledApplicationDeviceDevTop

Page 78: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Diagnostic Views5-3

EFDMIM Diagnostic View

TotalThe total number of network errors detected by the bridge.

Last PollThe number of network errors since the last network poll.

The Network Errors button accesses a rate graph displaying the total number of network errors over a given timeframe.

The Events button accesses the Event Log containing information on network events specific to the SNMP Bridge.

The Alarms button accesses the Alarm View containing information on alarms specific to the SNMP Bridge.

EFDMIM Diagnostic ViewThe initial EFDMIM Diagnostic View displays the following information:

Model NameThe user-defined name of the bridge model.

Network AddressThe Internet Protocol (IP) address of the EFDMIM.

Bridge NameThe user-defined name of the bridge. The default is Cabletron Enet-FDDI Bridge.

TotalThe total number of network errors detected by the bridge.

Last PollThe number of network errors since the last network poll.

Network Errors

Events

Alarms

Page 79: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Diagnostic ViewBridge Port Table

Diagnostic Views5-4

Cabletron SNMP BridgesManagement Module Guide

Bridge Port Table

This area of the EFDMIM Diagnostic View displays the current state of the EFDMIM Ethernet and FDDI ports and the amount of packets containing errors detected by each port.

Double-clicking on an entry in the State column accesses a port-specific Port Performance View. (Refer to the Port Performance View section in Chapter 6.)

Double-clicking on an entry in the Error Pkts column accesses a rate graph displaying the amount of error packets detected by the port over a given time frame.

The Network Errors button accesses a rate graph displaying the total number of network errors over a given timeframe. The total number of network errors detected by the EFDMIM and the number of errors since the last network poll are also displayed.

The Events button accesses the Event Log containing information on network events specific to the EFDMIM.

The Alarms button accesses the Alarm View containing information on alarms specific to the EFDMIM.

Network Errors

Events

Alarms

Page 80: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Performance Views6-1

Chapter 6

Performance Views

What is in this ChapterThis chapter describes the Performance View available for the Cabletron SNMP Bridges. The Performance View provides data attributes for the traffic on the network segments connected to the Cabletron bridge devices. This view summarizes traffic flow in frames.

Accessing the Performance ViewYou can access the Performance View by highlighting the bridge icon and selecting Performance from the Icon Subviews menu, or by double-clicking on the Performance Graph of the Location View bridge icon (refer to Figure 6-1).

Page 81: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Performance Views6-2

NB20E, NB25E and NB30 Performance View

Figure 6-1. Accessing the Performance View

NB20E, NB25E and NB30 Performance ViewThe SNMP Bridge Performance View provides the following information:

Model NameThe user-defined name of the bridge model.

Bridge StatusThe status of the SNMP Bridge (ON-LINE, STAND BY, or DISABLED).

Force the SNMP Bridge to reset its counters by clicking on this button. (Not available for NB30).

Bridge Name (NB30 only)The user-defined name of the bridge. The default is CABLETRON REMOTE BRIDGE for the NB30.

10

1

.1

.01

Double-click

Select Performance

CloseNavigateAlarmsPerformanceNotes...UtilitiesZoomConfigurationDiagnosticAcknowledge

Flash Green EnabledApplicationDeviceDevTop

Counters

Page 82: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Performance Views6-3

EFDMIM Performance View

Bridge UptimeThe time, in days+hours:minutes:seconds, since the SNMP Bridge’s network management software was last reinitialized.

This button accesses a rate graph displaying the number of forwarded frames over a given timeframe. Gauges below the button indicate the number of frames forwarded by the SNMP Bridge. This includes the total number of frames forwarded since the bridge was initialized, and the difference in frames forwarded between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

This button accesses a rate graph displaying the number of received frames over a given time frame. Gauges below the button indicate the number of frames received by the SNMP Bridge. This includes the total number of frames received since the bridge was initialized, and the difference in frames received between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

This button accesses a rate graph displaying the number of filtered frames over a given time frame. Gauges below the button indicate the number of frames filtered by the SNMP Bridge. This includes the total number of filtered frames since the bridge was initialized, and the difference in frames forwarded between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

EFDMIM Performance ViewThe EFDMIM Performance View provides the following information:

Model NameThe user-defined name of the bridge model.

Network AddressThe Internet Protocol (IP) address of the EFDMIM.

Bridge StatusThe status of the EFDMIM (ON-LINE, STAND BY, or DISABLED).

Receive PacketsThe number of packets received by the EFDMIM. This includes the total number of packets received since the EFDMIM was initialized, and the difference in packets received between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

Frames Forwarded

Frames Received

Frames Filtered

Page 83: Cabletron SNMP Bridges MMG (9030368)

EFDMIM Performance ViewPacket Breakdown Pie Chart

Performance Views6-4

Cabletron SNMP BridgesManagement Module Guide

Packet Breakdown Pie Chart

The Packet Breakdown color-coded pie chart displays the following network traffic information for the EFDMIM:

Fltr PktsThe total amount of packets received and filtered through the EFDMIM’s ports.

Fwrd PktsThe total amount of packets received and forwarded through the EFDMIM’s ports.

Xmit PktsThe total amount of packets transmitted on the EFDMIM ports.

Error PktsThe total amount of packets containing errors detected by the EFDMIM ports.

Bridge Port Table

This area of the EFDMIM Performance View provides the total number of each statistic displayed in the Packet Breakdown Pie Chart on a port by port basis. Double-clicking on any column entry accesses the EFDMIM Port Performance View. (Refer to the Port Performance View section of this chapter.)

Columns in the Bridge Port Table can be sorted incrementally using the Sort button as follows:

1. Single-click on the particular column label. The Sort button appears at the top of the table.

2. Single-click on the Sort button to sort that particular column. Statistical information is sorted in descending order.

The Bridge Port Table can be updated using the Update button. Columns that have been sorted will remain sorted as the table is updated.

Page 84: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Performance Views6-5

Port Performance View

Port Performance ViewThe Port Performance View provides statistical and current operating information for each port on the SNMP Bridge or EFDMIM. This view is accessed through the Application View HASPART Panel, the Device View or the Device Topology View. The EFDMIM Port Performance View can also be accessed from the EFDMIM Diagnostic or Performance View Bridge Port Table.

To access the Port Performance View from the Device View, follow these steps:

1. Click in the Device View with the right mouse button to display the pop-up menu.

2. Select Port Performance View from the pop-up menu.

There are three ways to access the Port Performance View from the DevTop View. One way to display a Port Performance View from the DevTop View is to double-click on either one of the gauges of a port representation in the Port Connections Panel. You can also display a Port Performance View from the DevTop view by following these steps:

1. Click on one of the gauges of a port representation in the Port Connections Panel with the right mouse button to display the pop-up menu.

2. Choose Performance from the pop-up menu.

Finally, you can display the Port Performance View from the DevTop View by following these steps:

1. Click on one of the gauges of a port representation in the Port Connections Panel to highlight the icon.

2. Choose Icon Subviews from the View menu.

3. Choose Performance from the Icon Subviews menu.

SNMP NB20E and NB25E Port Performance View

The SNMP Bridge Port Performance View provides the following information:

Model NameThe user-defined name of the bridge model.

Network AddressThe Internet Protocol (IP) address of the SNMP Bridge.

Bridge TypeThe type of bridge (e.g., NB20E or NB25E).

Page 85: Cabletron SNMP Bridges MMG (9030368)

Port Performance ViewSNMP NB20E and NB25E Port Performance View

Performance Views6-6

Cabletron SNMP BridgesManagement Module Guide

Port NameThe user-defined name assigned to the port. The default names are PORT_1 and PORT_2.

Port StatusThe current port operating status. Table 6-16 provides a list of the status messages.

This button accesses a rate graph displaying the number of received frames over a given time frame. Gauges below the button indicate the number of frames received by the specified port. This includes the total number of frames received by this port since the bridge was initialized, and the difference in frames received between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

This button accesses a rate graph displaying the number of discarded frames over a given time frame. Gauges below the button indicate the number of frames received by the specified port but discarded during the forwarding process. This includes the total number of frames discarded by this port since the bridge was initialized, and the difference in frames discarded between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

Table 6-1. Port Status Messages

Message Description

OFF Indicates that the port is not operational due to a failed network interface chip associated with that port.

OK/SQE ON Indicates that the port is communicating with the network and the transceiver has SQE (signal quality error) detection enabled.

OK/SQE OFF Indicates that the port is communicating with the network and the transceiver has SQE (signal quality error) detection disabled.

CARRIER LOST Indicates that communication with the network has not been established or has been lost.

Frames Received

Frames Discarded

Page 86: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Performance Views6-7

Port Performance View

SNMP NB20E and NB25E Port Performance View

This button accesses a rate graph displaying the number of forwarded frames over a given time frame. Gauges below the button indicate the number of frames forwarded by the specified port. This includes the total number of frames forwarded by this port since the bridge was initialized, and the difference in frames forwarded between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

This button accesses a rate graph displaying the number of received frames over a given time frame. Gauges below the button indicate the number of frames discarded by the specified port due to a lack of buffer space. This includes the total number of frames discarded by the port since the bridge was initialized, and the difference in frames discarded between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

This button accesses a rate graph displaying the number of discarded frames over a given time frame. Gauges below the button indicate the number of frames that were intended for forwarding by the specified port but were discarded because the maximum time allowed for transmission was exceeded. This includes the total number of frames discarded by the port since the bridge was initialized, and the difference in frames discarded between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

Two additional buttons are available from the SNMP NB20E and NB25E Port Performance View.

The Port Diagnostics button accesses the Port Diagnostic View. The Port Diagnostic View provides the following information:

Model NameThe user-defined name of the bridge model.

Network AddressThe Internet Protocol (IP) address of the Bridge.

Bridge TypeThe type of bridge (e.g., NB20E or NB25E.)

Frames Forwarded

Frames Dscrd No Buff

Frames DiscrdTimeout

Port Diagnostics

Page 87: Cabletron SNMP Bridges MMG (9030368)

Port Performance ViewSNMP NB20E and NB25E Port Performance View

Performance Views6-8

Cabletron SNMP BridgesManagement Module Guide

This button accesses a rate graph displaying the number of giant packets over a given time frame. Fields to each side of the button indicate the amount of giant packets that could not be transmitted by the port as both a total since the bridge was initialized, and the total since the last poll. A giant packet exceeds 1518 bytes not including preamble.

This button accesses a rate graph displaying the number of port collisions over a given time frame. Fields to each side of the button indicate the total amount of collisions detected by the port as both a total since the bridge was initialized, and the total since the last poll.

Xmits AbortedIndicates the number of attempted transmissions that have been aborted due to excessive collisions as both a total since the bridge was initialized, and the total since the last poll. Before SPECTRUM aborts transmission, over sixteen attempts are made to send the packet.

OOW CollisionsIndicates the amount of collisions out of the standard window (51.2µs) due to a network problem as both a total since the bridge was initialized, and the total since the last poll.

CRC ErrorsIndicates the amount of packets received by the port with bad Cyclical Redundancy Checks (CRC) as both a total since the bridge was initialized, and the total since the last poll.

Alignment ErrorsIndicates the amount of misaligned packets detected by the port as both a total since the bridge was initialized, and the total since the last poll.

The Port Configuration button accesses the Port Configuration View. The Port Configuration View provides the following information:

Model NameThe user-defined name of the bridge model.

Network AddressThe Internet Protocol (IP) address of the SNMP Bridge.

Bridge Type The type of bridge (e.g., NB20E or NB25E).

Port NumberThe number of the port.

Giants

Collisions

Port Configuration

Page 88: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Performance Views6-9

Port Performance View

EFDMIM Port Performance View

Port NameThe user-defined name assigned to the port. The default names are PORT_1 and PORT_2.

Port AddressThe Ethernet address of the port.

Port TypeThe IEEE specification of the port (e.g., 802.3).

Port PriorityThe part of the port identifier used with the spanning tree algorithm in determining which port in a LAN segment has priority.

Port Path CostThe contributory cost of the port to the total cost of the path when the specific port is the root port. The allowable range is from 1 to 65,535.

Port to Root Bridge CostThe cost of the path of this port to the root bridge on the network.

LAN PortThe SNMP Bridge port that is designated port for communication with the LAN.

Topology Change ACKA read-only indicator button displaying the value of the topology change acknowledgment flag in the next configuration BPDU to be transmitted on this port.

Port Network NameThe name of the network segment connected to the port. The default names are LAN-1 and LAN-2.

Port Root DesignatorThe identification of the root bridge on the network.

EFDMIM Port Performance View

The EFDMIM Port Performance View provides the following information:

Model NameThe user-defined name of the bridge model.

Network AddressThe Internet Protocol (IP) address of the EFDMIM.

Port NumberThe number of the selected port.

Page 89: Cabletron SNMP Bridges MMG (9030368)

Port Performance ViewEFDMIM Port Performance View

Performance Views6-10

Cabletron SNMP BridgesManagement Module Guide

A read-only indicator button displaying the current operational state of the port (UP, DOWN, or TESTING).

The required operational state of the EFDMIM (UP, DOWN, or TESTING) selectable through this button and reflected in the Port Status read-only indicator button.

Receive PacketsThe number of packets received by the EFDMIM. This includes the total number of packets received since the EFDMIM was initialized, and the difference in packets received between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

Port Packet Breakdown Pie Chart

The Port Packet Breakdown color-coded pie chart displays the following network traffic information for the specific port:

Fltr PktsThe total amount of packets received and filtered through the port.

Fwrd PktsThe total amount of packets received and forwarded through the port.

Xmit PktsThe total amount of packets transmitted on the port.

Error PktsThe total amount of packets containing errors detected by the port.

No additional buttons or subviews are available from the EFDMIM Port Performance View.

Port Status

Admin State

Page 90: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Performance Views6-11

Port Performance View

SNMP NB30 Local Port Performance View

SNMP NB30 Local Port Performance View

The SNMP NB30 Local Port Performance View provides the following information:

Model NameThe user-defined name of the bridge model.

Network AddressThe Internet Protocol (IP) address of the SNMP Bridge.

Bridge TypeThe type of bridge (e.g., NB30).

Bridge StatusThe status of bridge (ON-LINE, STAND BY, or DISABLED).

Bridge UptimeThe time, in days+hours:minutes:seconds, since the SNMP Bridge’s network management software was last reinitialized.

This button accesses a rate graph displaying the number of received frames over a given time frame. Gauges below the button indicate the number of frames received by the specified port. This includes the total number of frames received by this port since the bridge was initialized, and the difference in frames received between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

This button accesses a rate graph displaying the number of filtered frames over a given time frame. Gauges below the button indicate the number of frames filtered by the specified port. This includes the total number of frames filtered by this port since the bridge was initialized, and the difference in frames filtered between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

This button accesses a rate graph displaying the number of forwarded frames over a given time frame. Gauges below the button indicate the number of frames forwarded by the specified port. This includes the total number of frames forwarded by this port since the bridge was initialized, and the difference in frames forwarded between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

Frames Received

Frames Filtered

Frames Forwarded

Page 91: Cabletron SNMP Bridges MMG (9030368)

Port Performance ViewSNMP NB30 Local Port Performance View

Performance Views6-12

Cabletron SNMP BridgesManagement Module Guide

This button accesses a rate graph displaying the number of received frames over a given time frame. Gauges below the button indicate the number of frames discarded by the specified port due to a lack of buffer space. This includes the total number of frames discarded by the port since the bridge was initialized, and the difference in frames discarded between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

This button accesses a rate graph displaying the number of discarded frames over a given time frame. Gauges below the button indicate the number of frames that were intended for forwarding by the specified port but were discarded because the maximum time allowed for transmission was exceeded. This includes the total number of frames discarded by the port since the bridge was initialized, and the difference in frames discarded between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

Two additional buttons are available from the SNMP NB30 Local Port Performance View.

The Port Diagnostics button accesses the Port Diagnostic View. The Port Diagnostic View provides the following information:

Model NameThe user-defined name of the bridge model.

Network AddressThe Internet Protocol (IP) address of the Bridge.

Bridge TypeThe type of bridge (e.g., NB30).

Bridge UptimeThe time, in days+hours:minutes:seconds, since the SNMP Bridge’s network management software was last reinitialized.

Discarded – No Buffer

Discarded – Timeout

Port Diagnostics

Page 92: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Performance Views6-13

Port Performance View

SNMP NB30 Local Port Performance View

This button accesses a rate graph displaying the number of giant packets over a given time frame. Fields to each side of the button indicate the amount of giant packets that could not be transmitted by the port as both a total since the bridge was initialized, and the total since the last poll. A giant packet exceeds 1518 bytes not including preamble.

This button accesses a rate graph displaying the number of port collisions over a given time frame. Fields to each side of the button indicate the total amount of collisions detected by the port as both a total since the bridge was initialized, and the total since the last poll.

Xmits AbortedIndicates the number of attempted transmissions that have been aborted due to excessive collisions as both a total since the bridge was initialized, and the total since the last poll. Before SPECTRUM aborts transmission, over sixteen attempts are made to send the packet.

OOW CollisionsIndicates the amount of collisions out of the standard window (51.2µs) due to a network problem as both a total since the bridge was initialized, and the total since the last poll.

CRC ErrorsIndicates the amount of packets received by the port with bad Cyclical Redundancy Checks (CRC) as both a total since the bridge was initialized, and the total since the last poll.

Alignment ErrorsIndicates the amount of misaligned packets detected by the port as both a total since the bridge was initialized, and the total since the last poll.

The Port Configuration button accesses the Port Configuration View. The Port Configuration View provides the following information:

Model NameThe user-defined name of the bridge model.

Network AddressThe Internet Protocol (IP) address of the SNMP Bridge.

Bridge Status The status of the bridge (ON-LINE, STAND BY, or DISABLED).

Bridge Name The name of the bridge (e.g., NB30).

Giants

Collisions

Port Configuration

Page 93: Cabletron SNMP Bridges MMG (9030368)

Port Performance ViewSNMP NB30 Local Port Performance View

Performance Views6-14

Cabletron SNMP BridgesManagement Module Guide

Bridge Type The type of bridge (e.g., CABLETRON REMOTE BRIDGE).

Bridge ID The Ethernet (MMAC) address of the bridge.

Port NameThe user-defined name assigned to each local port. The default names are PORT_1 and PORT_2.

Port StatusThe status of each local port (ON-LINE, STAND BY, or DISABLED).

Port TypeThe IEEE specification of each local port (e.g., 802.3).

Port AddressThe Ethernet address of each local port.

Network NameThe name of the network segment connected to the port. The default names are LAN-1 and LAN-2.

Max RetriesThe maximum number of retries for the redundant port algorithm on the NB30. Valid range is 2-99 retries.

Polling IntervalThe time, in seconds, between SpectroSERVER polls of the network for a specific model.

Polling AddressThe polling address that will be used by the redundant port algorithm on the NB30.

Redundancy CheckingThe state of the Redundancy Enable Flag (Valid options are Enabled or Disabled).

Active Local PortThe number of the port that is acting as the online Ethernet port on the NB30.

Default Local PortThe number of the port that is default Ethernet port on the NB30.

One additional button is available from the NB30 Local Port Configuration View.

The Topology Settings button accesses the Port Topology Settings View. Table 6-2 provides a list of the Port Topology Settings View fields.

Topology Settings

Page 94: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Performance Views6-15

Port Performance View

SNMP NB30 Local Port Performance View

Table 6-2. Port Topology Settings View Fields

Field Description

Model Name The user-defined name of the bridge model.

Bridge Name The name of the NB30. Default is CABLETRON REMOTE BRIDGE.

Bridge ID The Ethernet address of the bridge.

Network Address The Internet Protocol (IP) address of the SNMP Bridge.

Bridge Type The type of bridge (e.g., NB30).

Bridge Status The status of the bridge (ON_LINE or STAND BY).

Port Priority The part of the port identifier used with the spanning tree algorithm in determining which port in a LAN segment has priority.

Port State The current state of the port. (Possible values are DISABLED, LISTENING, LEARNING, FORWARDING, and BLOCKING).

Port Path Cost The contributory cost of the port to the total cost of the path when the specific port is the root port. The allowable range is from 1 to 65,535.

Designated Root The bridge identifier of the bridge recorded as the root in Configuration BPDUs transmitted by the Designated Bridge for the segment to which this port is attached. This value is used as the Root Identifier parameter in all Bridge Configuration PDUs originated by this node.

Designated Bridge The Bridge ID of the bridge that is assumed to be the root bridge on the network.

Designated Cost The cost of the path of this port to the root bridge on the network.

Designated Port The SNMP Bridge port that is designated port for communication with the LAN.

Topology Change ACK A read-only indicator button displaying the value of the topology change acknowledgment flag in the next configuration BPDU to be transmitted on this port.

!CAUTION

Do not use these controls if you have not configured the NB30 with redundant port hardware. Enabling redundancy or changing the active port could cause loss of contact with the bridge.

Page 95: Cabletron SNMP Bridges MMG (9030368)

Port Performance ViewSNMP NB30 Remote Port Performance View

Performance Views6-16

Cabletron SNMP BridgesManagement Module Guide

SNMP NB30 Remote Port Performance View

The NB30 Remote Port Performance View provides the following information:

Model NameThe user-defined name of the bridge model.

Network AddressThe Internet Protocol (IP) address of the NB30.

Port TypeThe type of remote port, (DSX-1, V35, or Rs449) and the current setting for the Frame Format Switch (ESF or D4). For more information on setting the Frame Format Switch, refer to the NB30 Remote Ethernet Bridge User’s Manual.

Port NameThe user-defined name assigned to the port. The default name is REMOTE PORT.

Port StatusThe current port operating status. Status messages are as follows:

NO EXT CLOCKDCE NOT READY / NO DMDCE NOT READY / NO CTSLINK OK / DCE READYNET LOOP / RED ALARMREM LOOP / RED ALARMNORMAL / RED ALARMNET LOOP / YELLOW ALARMREM LOOP / YELLOW ALARMNORMAL / YELLOW ALARMNET LOOP / LINK OKREM LOOP / LINK OKNORMAL / LINK OKNET LOOP / LINK LOSTREM LOOP / LINK LOSTNORMAL / LINK LOST

For definitions of status messages refer to the NB30 Remote Ethernet Bridge User’s Manual.

This button accesses a rate graph displaying the number of received frames over a given time frame. Gauges below the button indicate the number of frames received by the specified port. This includes the total number of frames received by this port since the bridge was initialized, and the difference in frames received between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

Frames Received

Page 96: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Performance Views6-17

Port Performance View

SNMP NB30 Remote Port Performance View

This button accesses a rate graph displaying the number of discarded frames over a given time frame. Gauges below the button indicate the number of frames received by the specified port but not discarded during the forwarding process. This includes the total number of frames not discarded by this port since the bridge was initialized, and the difference in frames discarded between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

This button accesses a rate graph displaying the number of received frames over a given time frame. Gauges below the button indicate the number of frames discarded by the specified port due to a lack of buffer space. This includes the total number of frames discarded by the port for lack of buffer space since the bridge was initialized, and the difference in frames discarded between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

This button accesses a rate graph displaying the number of discarded frames over a given time frame. Gauges below the button indicate the number of frames that were intended for forwarding by the specified port but were discarded because the maximum time allowed for transmission was exceeded. This includes the total number of frames discarded by the port due to timeout since the bridge was initialized, and the difference in frames discarded between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

This button accesses a rate graph displaying the number of received frames over a given time frame. Gauges below the button indicate the number of frames discarded by the specified port due to a framing error. This includes the total number of frames discarded by the port due to framing errors since the bridge was initialized, and the difference in frames discarded between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

This button accesses a rate graph displaying the number of received frames over a given time frame. Gauges below the button indicate the number of frames discarded by the specified port due to a Cyclical Redundancy Check error. This includes the total number of frames discarded by the port due to CRC errors since the bridge was initialized, and the difference in frames discarded between the previous SpectroSERVER poll and the current poll presented as both a total number and a dynamic horizontal bar gauge.

Frames Forwarded

Discarded – No Buffer

Discarded – Timeout

Discarded – Framing

Discarded – CRC

Page 97: Cabletron SNMP Bridges MMG (9030368)

Port Performance ViewSNMP NB30 Remote Port Performance View

Performance Views6-18

Cabletron SNMP BridgesManagement Module Guide

Two additional buttons are available from the NB30 Remote Port Performance View, as follows:

The Port Diagnostics button accesses the DSX-1 Loopback Test View. The DSX-1 Loopback Test View provides the following information:

Bridge NameThe name of the NB30. Default is CABLETRON REMOTE BRIDGE.

Network AddressThe Internet Protocol (IP) address of the NB30.

Bridge StatusThe status of the bridge (ON_LINE or STAND BY).

Testing StatusThe current port testing status (Not_Testing, Testing, Network, Passed, or Failed).

Single-click on this button to enable this option. This starts a loop back test.

Single-click on this button to enable this option. This stops loop back testing and returns the device to service.

Select one of the valid parameters for this field, (Alternating_1/0s, All_1s, All_0s, or Incrementing_Data) by clicking on this button and dragging to the selection.

The Port Configuration button accesses the DSX-1 Port Configuration View. The DSX-1 Port Configuration View provides the following information:

Port Diagnostics

Loop Up

Loop Down

Test Pattern

!CAUTION

Enabling a loop back test on a remote NB30 will make the device non-responsive to SNMP-Based commands, and you will lose contact. Loop back testing should ONLY be enabled on LOCAL NB30 devices. You should always be certain which NB30 is local and which is remote.

Port Configuration

Page 98: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Performance Views6-19

Port Performance View

SNMP NB30 Remote Port Performance View

Port NameThe name of the NB30 port. The default name is REMOTE PORT.

Network NameThe name of the network segment connected to the port.

Port TypeThe type of remote port, (DSX-1) and the current setting for the Frame Format Switch (ESF or D4). For more information on setting the Frame Format Switch refer to the NB30 Remote Ethernet Bridge User’s Manual.

Bridge StatusThe status of the bridge (ON_LINE or STAND BY).

Port StatusThe current port operating status. Status messages are as follows:

NO EXT CLOCKDCE NOT READY / NO DMDCE NOT READY / NO CTSLINK OK / DCE READYNET LOOP / RED ALARMREM LOOP / RED ALARMNORMAL / RED ALARMNET LOOP / YELLOW ALARMREM LOOP / YELLOW ALARMNORMAL / YELLOW ALARMNET LOOP / LINK OKREM LOOP / LINK OKNORMAL / LINK OKNET LOOP / LINK LOSTREM LOOP / LINK LOSTNORMAL / LINK LOST

For definitions of status messages refer to the NB30 Remote Ethernet Bridge User’s Manual.

Channel 1 through 24Toggle this parameter to enable or disable the selected channel.

NOTE

The Port Diagnostics and Port Configuration buttons are not available for the V.35 and RS449 remote ports.

Page 99: Cabletron SNMP Bridges MMG (9030368)

Port Performance ViewSNMP NB30 Remote Port Performance View

Performance Views6-20

Cabletron SNMP BridgesManagement Module Guide

!CAUTION

Be certain that both NB30 bridges are configured to use the same channels. When changing the channels used, always change the LOCAL NB30 first, and then change the REMOTE NB30 to correspond to the new configuration for the local device.

Page 100: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Event and Alarm Messages7-1

Chapter 7

Event and Alarm Messages

What is in this ChapterThis chapter describes the events and alarms that Cabletron SNMP Bridge devices generate. Additionally, this appendix notes if an event is mapped to an identical alarm message, and provides any probable cause messages corresponding to these alarms.

The events and alarms generated by the model type designations listed below are described in the sections that follow:

• SNMP NB20E• SNMP NB25E• NB30

Events and alarms originate as generic Simple Network Management Protocol (SNMP) traps sent from the physical bridge device. SPECTRUM translates these traps, or unsolicited messages, as events and displays them in the Event Log. The EFDMIMdoes not support traps. For more information on specific traps generated by each device, refer to RFC 1213 available through the Internet system. Also refer to the Management Information Base (MIB) documentation for each specific bridge device.

NOTE

Each event/alarm listed below includes: the event code, the event/alarm message, followed by a brief description of the event/alarm, an alarm mapping indicator, and any probable cause message for the mapped alarm. When variable data is inserted in a message, it is indicated by a {v}. Data in parenthesis will be replaced by the named variable followed by a specific value, without the parenthesis.

Management Module Guide for the Cabletron Systems SNMP Bridges

Page 101: Cabletron SNMP Bridges MMG (9030368)

NB20E, NB25E, and NB30 Events and Alarms

Event and Alarm Messages7-2

Cabletron SNMP BridgesManagement Module Guide

NB20E, NB25E, and NB30 Events and AlarmsTable 7-1 provides the events and alarms supported by SPECTRUM for the SNMP NB20E, and SNMP NB25E bridge devices. For a specific list of events that have been generated by a specific hub device, click on a bridge device icon, select New View from the View menu, and select the Performance option. When the Performance View appears, press the Events button to bring up the Event View displaying all the events that have occurred on that device. The event message files are located in the following directory:

/SPECTRUM Directory Path/SG-Support/CsEvFormat

The alarm message files are located in the following directory:

/SPECTRUM Directory Path/SG-Support/CsPCause

Table 7-1. Events and Alarms

Event Message Probable Cause Message

00010203

The model created is not the same type as the device. Model type = {v}, Name = {v}, User = {v}.

00010203

The model created is not the same type as the device. (This is a SPECTRUM Intelligence alarm and is supported by the EFDMIM.)

00010306

A(n) {v} device, named {v}, has been cold started.

00010306

Not Applicable.

00010307

A(n) {v} device, named {v}, has been warm started.

00010307

Not Applicable.

00010308

A(n) {v} device, named {v}, has detected a Communication Link Down.

00010308

Communication link is down.

00010309

A(n) {v} device, named {v}, has detected a Communication Link Up.

00010309

Not Applicable.

0001030a

A(n) {v} device, named {v}, has detected an Authorization Failure.

0001030a

Authorization failure. Other user is trying to connect to device with an invalid Community String.

Page 102: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Event and Alarm Messages7-3

NB20E, NB25E, and NB30 Events and Alarms

0001030b

A(n) {v} device, named {v}, has detected an EGP Neighbor or Loss. EGP Neighbor IP address is {0 1}.

0001030b

Lost contact with EGP Neighbor.

00010401

Device {v} of type {v} is created with an IP address already used by another model.

00010401

DUPLICATE IP ADDRESS

The model has the same IP address as that of some other Model. (This is a SPECTRUM Intelligence alarm and is supported by the EFDMIM.)

00010402

Device {v} of type {v} is created with a physical (Mac) address already used by another model.

00010402

DUPLICATE PHYSICAL ADDRESS

The model has the same Physical address (Mac address) as that of some other model. (This is a SPECTRUM Intelligence alarm and is supported by the EFDMIM.)

00010625

Network configuration changes reported by {v} (name - {v}). {v} (name - {v}) status is now {v} (Instance ID {v}).

00010625

Not Applicable.

00010626

Device configuration change reported by {v} (name - {v}). Acquired database of {v} (name - {v}) is full.

00010626

Not Applicable.

00010701

Alarm number {v} generated for device {v} of type {v}. Current condition is {v}.

00010701

Not Applicable.(This is a SPECTRUM Intelligence alarm and is supported by the NB30.)

Table 7-1. Events and Alarms (Continued)

Event Message Probable Cause Message

Page 103: Cabletron SNMP Bridges MMG (9030368)

NB20E, NB25E, and NB30 Events and Alarms

Event and Alarm Messages7-4

Cabletron SNMP BridgesManagement Module Guide

Page 104: Cabletron SNMP Bridges MMG (9030368)

9030368 E91

IndexAAccessing 2-9Accessing the

Configuration View 4-1Device View 2-1Performance View 6-1

AcquiredDatabase 3-4

Information View 3-7Table Button 3-7

Entry 3-8, 3-9Active Local Port 6-14Actual Representation 2-9Add

Entry 3-9New Database Entry 3-5, 3-7, 3-9

AdditionalBridge Information Button 4-4Bridge Information View 4-4Configuration Button 4-9

Admin State 6-10Alarm

Log 5-1Messages 7-1View 5-3, 5-4

Alarms 2-30, 2-31Button 5-3, 5-4

Align_Errors 2-13, 2-14, 2-18, 2-19Alignment Errors 6-8, 6-13All_0s 6-18All_1s 6-18Alternating_1/0s 6-18A-Ports 3-11Application

View 2-31, 3-1

BBdg 1-1Bdg_CSI

EFDMIM 1-2, 2-31SNB20 1-1

BdgCSINB30 1-1BLOCKING 6-15

State 4-7Board Name 2-12, 2-16BPDU 4-4, 4-12, 6-9B-Ports 3-11Bridge

Address 4-9Configuration 2-1

PDUs 6-15ID 4-5, 6-14, 6-15Location 4-4, 4-9Mode 4-10Name 4-3, 4-9, 5-2, 5-3, 6-2, 6-13, 6-15,

6-18Port Table 5-4, 6-4Priority 4-4, 4-5Protocol Data Unit 4-4, 4-12Restart 4-8Settings 4-8Setup

Information Button 4-5Status 4-12, 6-2, 6-3, 6-11, 6-13, 6-15,

6-18, 6-19Control 4-7, 4-12

Type 4-3, 5-2, 6-5, 6-7, 6-8, 6-11, 6-12, 6-14, 6-15

Uptime 4-9, 6-3, 6-11, 6-12Bridge/Root Information

Button 4-4View 4-4

Broadcasts 4-6Bypass 4-12

Attached 4-10Stuck 4-10

Bytes 2-13, 2-18

Page 105: Cabletron SNMP Bridges MMG (9030368)

Index2

Cabletron SNMP BridgesManagement Module Guide

CCabletron

Enet-FDDI Bridge 4-9, 5-3CABLETRON REMOTE 4-3

BRIDGE 5-2, 6-2, 6-14, 6-15, 6-18Canonical

Format 4-10Representation 3-11

CARRIER LOST 6-6Case

#1 2-30#2 2-30

CFM State 4-10Changing

MIM Representations 2-25On The Entire Hub 2-28Using The Menu Bar 2-28Using The Mouse 2-29

Channel 1 Through 24 6-19Claim/Beacon Process 3-12, 4-10, 4-11Clear 2-30, 2-31

To Send 2-7Clearing Duplicate EFDMIM Address

Alarms 2-29COL 2-23Collision 2-24

Button 6-8, 6-13Present 2-4, 2-8Rate 2-23

Comments xiiiCommunity Name 4-3, 4-8Concentrator 3-11Configuration

BPDUs 4-7, 6-15Changes 2-2, 2-5Management State 4-10View 2-31

Control Button 4-7, 4-12Conventions xiiCopy 2-27Cost Path 4-4Counters 4-8, 4-13, 6-2CP 2-4, 2-8CRC 2-14, 2-18, 6-8, 6-13

Errors 2-13, 2-14, 2-18, 2-19, 6-8, 6-13CsEvFormat 7-2CSIBrdg_LPort $ 3-11CSIBrdgPrtDSX 3-11CSIBrdgPrtV35 $ 3-11

CSIRptr Port 2-26CsPCause 7-2CTS 2-7Current

Bridge Status 4-7Entries 3-5Operating Information 6-5

Cyclical Redundancy Checks 2-14, 2-18, 6-8, 6-13

DD4 6-19

Frame Format 4-6Data

Attributes 6-1Field 3-10Mode 2-7

Control Signal Switch 4-6Path 4-4

DatabaseEntries 3-4, 3-5Information 3-1

DCE 2-7NOT READY / NO CTS 6-16, 6-19NOT READY / NO DM 6-16, 6-19

DEC 4-5, 4-6BPDU 4-12LAN Bridge 100 Environment 4-5, 4-6

DefaultLocal Port 6-14Settings 4-8

DeleteFilter 3-10Special Database Filter View 3-10

DesignatedBridge 6-15Cost 6-15Port 6-15Root 6-15

Destination Address 3-10Detect 3-12, 4-11Device

Actions 1-1Associations 1-1Attributes 1-1Configuration 4-3, 4-9Models 1-1Type 2-15View 2-1

Page 106: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Index3

D (continued)Diagnostic 2-31

View 2-31Diagnostics 4-12Directed 3-12, 4-11

Beacons 3-12, 4-11Disabled 3-10, 4-6, 4-7, 4-12, 5-2, 6-2, 6-3,

6-11, 6-13, 6-14, 6-15Discarded

CRC Button 6-17Framing Button 6-17No Buffer Button 6-12, 6-17Timeout Button 6-12, 6-17

DisplayLogical MIMs 2-28Physical MIMs 2-28

DM 2-7Down 6-10Downstream

MAC 4-10Neighbor 4-10

DSX-1 6-19Loopback Test View 6-18Port Configuration View 6-18

Duplicate AddressAlarm 2-29

Dynamic 3-4, 3-7, 3-9Entries 3-4Entry Age Lmt 3-4

EEFD_If_Port # 3-13EFDMIM 1-2

Configuring inan IRM2 or IRM3 2-26

Control View 4-12Copying into Location or Topology

View 2-27Generic Views 2-31LEDs 2-22, 2-25Logical MIM Representation 2-16Physical MIM Representation 2-19Port Performance View 3-13, 6-4

Enable/Disable Filter 3-10Enabled 3-10, 4-6, 4-7, 6-14Encapsulating Bridge 4-10, 4-12Entry Type 3-7, 3-9Erase 3-4, 3-5

ErrorAttribute 5-1Count 4-13Data 2-2, 2-5, 2-9Pkts 5-4, 6-4, 6-10

ESF 6-19Frame Format 4-6

Ethernet 1-2, 2-8, 4-4, 4-5, 4-9, 4-12, 5-4, 6-9, 6-14

Bridge 4-3, 5-2Interface LEDs 2-23Port 2-8, 2-26

Performance View 3-11Event

Log 5-1, 5-3, 5-4, 7-1Messages 7-1

EventsButton 5-3, 5-4

FFailed 6-18FALSE 4-10FDDI 1-2, 4-9

Interface LEDs 2-22Port 4-10, 5-4Ring 2-22, 3-11, 4-11

Oscillation 4-9Token 3-11

Filter 3-7, 3-9by Data Field 3-10by Type Field 3-10Status 3-10

Filtering 3-5, 3-7, 3-9Database 3-1Information 3-9Options 3-5, 3-7, 3-9

Firmware 4-4Version 4-4, 4-5, 4-9

Fltr Pkts 6-4, 6-10Forward

Broadcast 2-8Delay 4-7

and Hello Information View 4-7Parm 4-7

ForwardBroad 4-12Forwarding 6-15

State 4-7

Page 107: Cabletron SNMP Bridges MMG (9030368)

Index4

Cabletron SNMP BridgesManagement Module Guide

F (continued)Frame

Count 4-13Format Switch 6-19Rate 2-23Type 3-10

Frames 2-13, 2-18, 2-24Discarded Button 6-6Discrd Timeout Button 6-7Dscrd No Buff Button 6-7Filtered Button 6-3, 6-11Forwarded Button 6-3, 6-7, 6-11, 6-17Received

Button 6-3, 6-6, 6-11, 6-16Front Panels 2-4, 2-7Fwd Dly & Hello Information Button 4-7Fwrd Pkts 6-4, 6-10

GGauge

Information 2-16, 2-26Mode Button 2-19, 2-24

General LEDs 2-22Generic

Views 2-2, 2-9Getting Help xiiGiant Packets 2-14, 2-18, 6-8, 6-13Giants 2-13, 2-14, 2-18, 2-19

Button 6-8, 6-13Go

Back 2-26Logical 2-28

HHardware Type 3-10HASPART

Panel 3-3, 3-11, 3-13Hello Time Parm 4-7Help xiiiHold Time 4-4Horizontal Bar Gauge 2-15, 2-18, 2-23, 6-3,

6-6, 6-7, 6-10, 6-11, 6-16, 6-17Hub Chassis 2-9

IIcon

Manager 2-2Incrementing_Data 6-18Internal

Loop Back Test 2-4, 2-7, 2-8Port 2-26

Internet 7-1Protocol 4-3, 4-8, 4-9, 5-3, 6-3, 6-5, 6-7,

6-8, 6-9, 6-11, 6-12, 6-13, 6-15, 6-16, 6-18

Introduction 1-1IP 2-25, 4-3, 4-8, 4-9, 5-3, 6-3, 6-5, 6-7, 6-8,

6-9, 6-11, 6-12, 6-13, 6-15, 6-16, 6-18IRBM 2-9IRM 2-9

Cabletron Proprietary 2-23IRM2 2-9IRM3 2-9Isolated 3-12, 4-10, 4-11

JJumper Settings 4-12

LLAN

Port 6-9LAN-1 6-9, 6-14LAN-2 6-9, 6-14LANVIEW LEDs 2-22Last Poll 5-3LEARNING 6-15

State 4-7LED Definitions 2-4, 2-7Lin Button 2-23Linear Scale 2-23LINK

A/B 2-22OK 2-7OK / DCE READY 6-16, 6-19

LISTENING 6-15State 4-7

Local 4-4, 4-9NB30 2-7Port 3-1

Location 2-15Log Button 2-23

Page 108: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Index5

L (continued)Logarithmic Scale 2-23Logical

Connection Pipe 2-26Gauges Button 2-18, 2-24Representation 2-26

LoopBack Test 6-18Down 6-18Up 6-18

LostCount 4-13

MMAC Address 3-11Management

Information Base 1-1, 7-1Master

Phys 3-11Ports 3-11

MaxNumber of Filters 3-3Retries 6-14

Maximum Entries 3-4, 3-5Menu Bar Access 2-1Message

DUPLICATE IP ADDRESS 2-30, 2-31DUPLICATE-PHYSICAL ADDRESS 2-

31MIB 1-1, 7-1MIM

Configuration View 2-25Diagnostic View 2-30

Misaligned Packets 2-14, 2-18, 6-8, 6-13MMAC 6-14

Backplane 2-23Device

Panel 2-15Statistics Panel 2-23

Interface LEDs 2-23Mode 4-12Model 1-1

Configuration 4-3, 4-8Name 3-3, 3-7, 3-9, 3-11, 4-3, 4-4, 4-5,

4-6, 4-7, 4-8, 4-9, 4-12, 5-2, 5-3, 6-2, 6-3, 6-5, 6-7, 6-8, 6-9, 6-11, 6-12, 6-13, 6-15, 6-16

Type 3-3, 3-11

MonitoringPoint 2-15

Multi-Attribute Line Graph 2-23My Duplicate 3-12

NName 2-15NB20E 1-1NB25E 1-1NB30

Front Panel Switches 2-8LEDs 2-7Local Port Performance View 6-11Remote Port Performance View 6-16T1 Remote Bridge 1-1

Net Address 2-15NET LOOP

LINKLOST 6-16, 6-19OK 6-16, 6-19

RED ALARM 6-16, 6-19YELLOW ALARM 6-16, 6-19

Network 6-18Address 3-3, 3-11, 4-3, 4-8, 4-9, 4-12, 5-

3, 6-3, 6-5, 6-7, 6-8, 6-9, 6-11, 6-12, 6-13, 6-15, 6-16, 6-18

Configuration 2-2, 2-5, 2-9Information 4-1

Errors 5-1Button 5-3, 5-4

Interface Chip 6-6Manager 3-4Name 6-14, 6-19Protocol Traffic 3-1Segment 3-3, 5-1, 6-1Traffic 6-10

Networking Software 3-10New

View 7-2Next Available Filter 3-9NLNK 2-12, 2-16NO EXT CLOCK 6-16, 6-19No Link 2-12, 2-16Node 3-11

Class 3-11Non

Op 3-12, 4-11Dup 3-12, 4-11

NonMaster 3-11

Page 109: Cabletron SNMP Bridges MMG (9030368)

Index6

Cabletron SNMP BridgesManagement Module Guide

N (continued)NORMAL

LINKLOST 6-16, 6-19OK 6-16, 6-19

RED ALARM 6-16, 6-19YELLOW ALARM 6-16, 6-19

Not_Testing 6-18Notice iNumber of

Filters 3-3Ports 4-4Restarts 4-5

OOFF 2-12, 2-16, 6-6OK/SQE

OFF 6-6ON 6-6

ON 2-12, 2-16NET 2-22

ON-LINE 2-4, 4-7, 4-12, 5-2, 6-2, 6-3, 6-11, 6-13, 6-14, 6-15, 6-18, 6-19

OOW Collisions 6-8, 6-13Optical

Bypass 4-12Switch 4-10

Signal 2-22Oscillations 4-10OutofWindow 2-13, 2-14, 2-18, 2-19

PPacket

Breakdown Pie Chart 6-4Passed 6-18Paste 2-27Percentages 2-19, 2-24Performance 6-5, 7-2

View 2-31Permanent

Database 3-5Information View 3-6

Entry 3-6, 3-7PHY

A 4-10B 4-10

Physical

Bridge Device 7-1Features 2-19Image 2-16Representation 2-26Status 2-2, 2-5, 2-9

Pie Chart 6-4, 6-10POK 2-4, 2-7, 2-8, 2-23Poll

Cycle 2-4, 2-7, 2-9Log Ratio 4-3, 4-8

Polling 4-3Address 6-14Cycle 2-1, 4-1Interval 4-3, 4-8, 6-14Status 4-9

Port1 Filter/Relay 3-102 Filter/Relay 3-10Address 6-9, 6-14Configuration

Button 6-8, 6-13, 6-18View 6-8, 6-13

Connections Panel 6-5Diagnostic

Button 6-7, 6-12View 6-7, 6-12

Diagnostics Button 6-18Information 2-16, 2-26Name 6-6, 6-9, 6-14, 6-16, 6-19Network Name 6-9Number 2-12, 2-16, 6-8, 6-9OK 2-4, 2-7, 2-8Packet Breakdown Pie Chart 6-10Path Cost 6-9, 6-15Performance View 3-11, 5-4, 6-5Priority 6-9, 6-15Root Designator 6-9State 6-15Status 2-12, 2-16, 6-6, 6-10, 6-14, 6-16,

6-19To Root Bridge Cost 6-9Topology Settings View 6-14Type 6-9, 6-14, 6-16, 6-19

PORT_1 6-6, 6-9, 6-14PORT_2 6-6, 6-9, 6-14Port1 Out 3-5, 3-7, 3-9Port2 Out 3-5, 3-7, 3-9Power 2-7

On 2-22Up 2-4

Page 110: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Index7

P (continued)Preface xiPriority Comparisons 4-4Probable Cause Messages 7-1Protocol Max Age 4-4Prt_Bdg_SEnet # 3-11Prt1=Filter/Prt2=Filter 3-6, 3-8Prt1=Filter/Prt2=Relay_Prt1 3-6, 3-8Prt1=Relay_Prt2/Prt2=Relay_Prt1 3-6, 3-8

QQuestions xiii

RRate 2-19, 2-24

Graph 5-3, 5-4, 6-3, 6-6, 6-7, 6-11, 6-16, 6-17

Interval 5-1RCV 2-4, 2-8Receive 2-4, 2-8

Clock 2-7Packets 6-3, 6-10

Recv_Colls 2-13, 2-18Red

Alarm 2-7Redundancy

Checking 6-14Enable Flag 6-14

Redundant PortAlgorithm 6-14

Reinitialized 3-10Related Reading xiiRelay 3-7, 3-9REM LOOP

LINKLOST 6-16, 6-19OK 6-16, 6-19

RED ALARM 6-16, 6-19YELLOW ALARM 6-16, 6-19

RemoteDSX-1 Port 2-7NB30 2-7Port 2-7, 3-1, 6-16

Performance View 3-11RS449 Port 2-7V.35 Port 2-7

Restricted Rights Notice ii

Ring 4-12Duplicate 3-12Interface 2-22MACS 3-11Network 2-22Op 3-12, 4-11

Dup 3-12, 4-11Oscillations 4-13Table 3-11Topology 3-11Uptime 4-9

RMT State 4-10Rollup

Conditions 4-3Root 2-8, 4-6, 4-12

Brdg Max Age 4-4Bridge 4-4, 6-9, 6-15

ID 4-4Cost 4-4Identifier 6-15Port 4-4, 6-9Switch 4-6

Runt 2-14, 2-18Packets 2-14, 2-18

Runts 2-13, 2-19RX 2-22, 2-23

SSecurity

String 4-3, 4-8SEG 2-12, 2-16Segmented 2-12, 2-16Select Filtering 3-5, 3-7Self-Test 2-4, 2-22, 2-23, 3-12, 4-12Set to Next Available Filter 3-9Setup Information View 4-5Signal Quality Error 6-6Simple Network Management Protocol

Traps 7-1SMI 3-10

Page 111: Cabletron SNMP Bridges MMG (9030368)

Index8

Cabletron SNMP BridgesManagement Module Guide

S (continued)SNMP 1-1

BridgeAcquired Database Table 3-7Add an Entry View 3-9Configuration View 4-3Control View 4-7Filter Selection View 3-5, 3-7Special Database Filter Table 3-9

NB20E LEDs 2-4NB25E LEDs 2-4System Group View 3-10Traps 7-1

SoftwareOperating System 3-10Reset 4-8

Sort Button 6-4Sorting Incrementally 6-4Source Address 3-7, 3-9, 3-10

Tables 3-3Spanning Tree 4-4

Algorithm 4-5, 4-6, 6-9, 6-15Switch 4-6

Facilities 4-12Root 4-12

SpannTree 4-12Special Database 3-3

Information View 3-10Table Button 3-9

S-Ports 3-11STA Protocol 4-5, 4-6STAND BY 2-4, 2-7, 2-22, 4-7, 4-12, 5-2, 6-

2, 6-3, 6-11, 6-13, 6-14, 6-15, 6-18, 6-19

State Column 5-4Static 3-4, 3-7, 3-9

Entries 3-4Entry Age Lmt 3-4

Station 3-11Statistic Colors 2-18Statistical

Information 6-5Status 5-2

Banner 2-15Color 2-15

Structure of Management Information 3-10Suggestions xiiiSupport xiiiSwitch

1 4-62 4-63 4-64 4-6Settings 4-5, 4-12

SystemDescriptor 3-10Object ID 3-10OK 2-22UpTime 2-15, 3-10

TT1

Frame Format 4-6Signal 2-7Timing Mode Switch 4-6

TCP/IP Based Networks xiiTechnical Support xiiiTemplate 1-1Terminology xiiTest Pattern 6-18Testing 6-10, 6-18

Status 6-18Through

A 4-11B 4-11

TimeTopology Change 4-6

TOKISD 2-22Tools 2-30, 2-31Topology 6-9

Change 4-7ACK 6-15Count 4-7Flag 4-6

InformationButton 4-6View 4-6

Topology Settings Button 6-14Total 5-3

Entries 3-4Errors 2-13, 2-18, 2-19Interval 5-1

Trace 3-12, 4-11Trademarks iTraffic 6-1

Flow 2-2, 2-5, 2-9, 6-1Trans_Colls 2-13, 2-18, 2-19Translation Bridge 4-10, 4-12

Page 112: Cabletron SNMP Bridges MMG (9030368)

9030368 E9 Index9

T (continued)Transmit 2-4, 2-8

Clock 2-7Trap Type Obj ID 4-5TRUE 4-10TX 2-22, 2-23Type of Filtering 4-5

UUNA Duplicate 3-12Unsolicited

Messages 7-1UP 6-10Up

Neighbor 3-11Upstream Neighbor 3-11, 4-11

VVarBinding 4-5Virus Disclaimer i

WWRAP 2-22Wrap

A 4-10AB 4-10B 4-10

XXmit

Aborted 6-8, 6-13Pkts 6-4, 6-10

XMT 2-4, 2-8

YYellow

Alarm 2-7