30
C-Technical part 1-Presentation

C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

  • Upload
    hamien

  • View
    244

  • Download
    0

Embed Size (px)

Citation preview

Page 1: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1-Presentation

Page 2: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/2

CUSTOMER VIEW- XBT N-JLD

06-2003

Chapter 1Chapter 1

Technical Presentation1.11.1

Communication possibilities1.21.2

Accesories1.31.3

Compatibility1.41.4

XBTL 1000 reminder1.51.5

Page 3: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/3

CUSTOMER VIEW- XBT N-JLD

06-2003

Technical Presentation1.11.1

Page 4: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/4

CUSTOMER VIEW- XBT N-JLD

06-2003

Magelis compact display units

4

multipointmonopoint

m XBT N200with alphanuméric screen

Display 2 linesof 20 charactersGreen screen

m XBT N400with matrix screen

Display 1 to 4 linesof 5 to 20 charactersGreen screen

m XBT N401with matrix screen

diaplay 1 to 4 linesof 5 to 20 charactersGreen screen / orange / red

m XBT NU400with matrix screen

Display 1 to 4 linesof 5 to 20 charactersGreen screenApplication for TeSysmodel U

Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP)

Uni-TelwayModbus

Uni-Telway Modbus Modbus

Page 5: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/5

CUSTOMER VIEW- XBT N-JLD

06-2003

Text display (LCD) :• 2 lines 20 characters for XBT-N200 (No big font)• Fonts : standard,katakana

Direct connection to PLC• RJ45 port for point to point communication• Protocol Unitelway-Modbus point to point

No 24 Vdc power supply needed• power supplied from PLC’s com port (5Vdc directly on the

PLC connection cable or on the computer cable during thedownload)

Keys• 2 services keys and 2 keys for the links with other pages• 4 customizable service keys configurable as funtion keys

All the functionalities of the XBT-H811510

5

Physical features of XBT-N200

RJ45

MiniDIN

24VDC

128 application pages8 variables/pages64*20 enumerated list

Sub D9

XBTZ978

XBTZ945

TWIDO,MICRO,NEZA,PREMIUM,NANO

Page 6: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/6

CUSTOMER VIEW- XBT N-JLD

06-2003

Text display (LCD) :• 1 to 4 lines 5 to 20 char XBTN400 + scrolling with 25 lines .

7 Sizes of char.• Fonts : standard,cyrillic,katakana

Direct connection to PLC• 1 serial link RS485/RS232C- RJ45 port• Protocol Unitelway2-Modbus

No 24 Vdc power supply neededKeys

• 2 services keys and 2 keys for the links with other pages• 4 customizable service keys configurable as funtion keys

6

Physical features of XBT-N400

RJ45

MiniDIN

200 application pages40 variables/pages256 Alarm pages

Sub D9

XBTZ978

XBTZ945

TWIDO,MICRO,NEZA,PREMIUM,NANO

24VDC

Page 7: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/7

CUSTOMER VIEW- XBT N-JLD

06-2003

Use for Motor Starter Tesys Model U• Matrix screen ,1 to 4 lines of 5 to 20 characters•Modbus Multipoint communication only

Preloaded application for 15 Tesys Model UCommunication

•1 Sub D25 connectionDriving of 8 devices

•visualization parameters•adjust•diagnostic • Alarms management

Power supply 24VdcCompatibility with offer ATV : ATV 28 ,38 , 58Keys

2 services keys and 2 keys for the links with other pages4 customizable service keys configurable as funtion keys

Sub D9

Sub D25

XBTZ915

XBTZ938

Specificities of the Ultima dedicated XBTNU 400

Page 8: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/8

CUSTOMER VIEW- XBT N-JLD

06-2003

Matrix screen• 1 to 4 lines of 5 to 20 characters• 3 color matrix screen: Green, Orange, and Red. (on some

models only) Accessible by the PLC application.• Scrolling 25 lines , 7 sizes of char.

4 DEL for operator guidance:• Alarm , communication status, scrolling help up and down.

Requires 24 Vdc external supplyConnection for all Schneider PLC:

• SubD25 connector.• Multipoint communication• Protocols Unitelway and Modbus• (the second Mini din connection is not supported yet)

Keys• 2 services keys and 2 keys for the links with other pages• 4 customizable service keys configurable as funtion keys

Physical features of XBT-N401

COMMANDSTART LIGHTRINSE SEWAGE

ALARM

Default

24 V

200 application pages40 variables/pages256 Alarm pages64*20 enumerated list

Page 9: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/9

CUSTOMER VIEW- XBT N-JLD

06-2003

Visibility Distance 2mView angle 90° (horizontal and vertical)Life time :100 000 hAction Speed 300ms (to detect a key action or to do an actionrequired by the PLC)Luminosity:>15cd/m² (Candela) for the optimum and 30cd/m² forthe universal3 Levels of passwordFlush-mounted

Range General characteristics24 V

Page 10: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/10

CUSTOMER VIEW- XBT N-JLD

06-2003

1.21.2 Communication Possibilities

Page 11: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/11

CUSTOMER VIEW- XBT N-JLD

06-2003

Point-to-point connections:

TWIDOPLC

ModbusModbus ModbusUnitelway

1.21.2 Communication Possibilities

PLC /cablesTSX17- XBT Z958Twido/Micro/premium/nano/neza-XBT Z968Quantum- XBTZ9710Momentum- XBT Z9711TSX47/67/87- XBT Z 948SCA 62- XBT Z908

Page 12: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/12

CUSTOMER VIEW- XBT N-JLD

06-2003

Multidrop connection:

Unitelway

OROR

1.21.2 Communication Possibilities

Page 13: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/13

CUSTOMER VIEW- XBT N-JLD

06-2003

Multipoint connection:

Modbus

1.21.2 Communication Possibilities

Page 14: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/14

CUSTOMER VIEW- XBT N-JLD

06-2003

Point to point Connection for modular machines

M1 M1

Modbus+

Modbus Modbus

I/O I/O

1.21.2 Communication Possibilities

Page 15: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/15

CUSTOMER VIEW- XBT N-JLD

06-2003

Ethernet TCP/IP

Profibus DP

Interbus S

DeviceNet

CANopen

Modbus

CableFast

CPUADVANTIS

Point to point Connection for modular machines

1.21.2 Communication Possibilities

Page 16: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/16

CUSTOMER VIEW- XBT N-JLD

06-2003

1.31.3 Accessories

Page 17: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/17

CUSTOMER VIEW- XBT N-JLD

06-2003

New connection cables

ReferenceHMI

ConnectionRemote

ConnectionDesignation Type of Connection

XBT-Z978 RJ45 MiniDIN XBT-N200 or 400 cable with Twido RS485 – HMI/PLC

XBT-Z938 25-pin SubD RJ45 Tesys model U cable RS485– HMI/Tesys model U

XBT-Z9680 25-pin SubD(angled)

MiniDIN Cable for the XBT-N401 and

XBT-HPE, HM, PM, F withTwido/Nano/Micro/Premium

to increase the depth of

cabling

RS485 – HMI/PLC

XBT-Z945 RJ45 9-pin SubDPC-configured cable for theXBT-N200 or 400 with powersupply via the PS2 mouse

port

RS232 - power supply viathe PS2 mouse port

1.31.3 Accessories

Page 18: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/18

CUSTOMER VIEW- XBT N-JLD

06-2003

Protective transparent sheets (pack of 10):

Function:-Protects the terminal from contamination and small scratches

Requirements:- Can be replaced by the end customer (can be applied and removed withouttools)- Minimum reduction in the touch-sensitivity of the keys (maximum differentialof -25% on travel/effort

Relegendable key labelsXBL YN00 or XBL YN01

1.31.3 Accessories

Page 19: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/19

CUSTOMER VIEW- XBT N-JLD

06-2003

Accessory for flush assembly of the product:

Function:-Enables flush assembly of the product for customizing the panel of the machine with a flat inner insulation (not provided)-Can be used to improve protection or total seal of the display units for heavy-duty applications (e.g., Karcher washing system, outdoor use, etc.) using a flat inner insulation (not provided)

Requirements:-Must be easy to install-Must be possible to remove the product without removing the inner insulation

Replacement accessories:- Fixing brackets (12)- Re-usable labels, 2 models for the Optimum and Multifunction versions.

1.31.3 Accessories

Page 20: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/20

CUSTOMER VIEW- XBT N-JLD

06-2003

Compatibility1.41.4

Page 21: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/21

CUSTOMER VIEW- XBT N-JLD

06-2003

COMPATIBILITY OF PRODUCTS WITHIN THE NEW OFFER:-An XBT-N200 application is compatible with an XBT-N400 or XBT-401-An XBT-N400 application is compatible with an XBT-401

COMPATIBILITY OF PRODUCTS WITH THE OLD OFFER:

- An XBT-H8 and XBT-H0 application is compatible with an XBT-N400 or XBT-401

Compatibility1.41.4

Page 22: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/22

CUSTOMER VIEW- XBT N-JLD

06-2003

XBTL1000 Reminder1.51.5

Page 23: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/23

CUSTOMER VIEW- XBT N-JLD

06-2003

Single software package programs the Magelis range• Compatible with the current XBT-H as well as the new XBT-N,

up to XBT F• Running under Windows 98 / 2000 / XP• ( be careful, the new Tactile XBT G HMI uses the software

named Vijeo-designer)The HMI program resides in the HMI, not in PLC memory.

XBTL 1000 Software presentation

XBTL1000 Reminder1.51.5

Page 24: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/24

CUSTOMER VIEW- XBT N-JLD

06-2003

Intuitive and easy to learn• Wizards• Application/Demo examples• Help bubbles on fields for configuration• Direct access to the variables list built with PL7 / Concept• Built-in simulator, no PLC required to debug application• Reduce download time 30%

Enhanced functions• Multilingual support, import/export of texts for easy

translation• Numerated lists ( 64 messages of 20 characters )• Application can be password protected• Variables conditional display• Threshold controlled by PLC variable• XBTH Conversion• IEC syntax variables for Modbus protocol

XBTL1000 Reminder1.51.5

PL7-Pro

Page 25: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/25

CUSTOMER VIEW- XBT N-JLD

06-2003

1

Product Selection/Protocol Selection

2

Next

To create an application, select in the toolbar File/new than follow the assistant

XBTL1000 Reminder1.51.5

Page 26: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/26

CUSTOMER VIEW- XBT N-JLD

06-2003

1

Equipment configuration

2

Next

XBTL1000 Reminder1.51.5

Page 27: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/27

CUSTOMER VIEW- XBT N-JLD

06-2003

Language Selection

1

Next

XBTL1000 Reminder1.51.5

Page 28: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/28

CUSTOMER VIEW- XBT N-JLD

06-2003

Parameters configuration/Dialog table configuration

2

1

2

XBTL1000 Reminder1.51.5

Page 29: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/29

CUSTOMER VIEW- XBT N-JLD

06-2003

Dialog table details

Pre-defined functions list

Variable for the Start address of the list

Time cycle

Table selection

XBTL1000 Reminder1.51.5

Page 30: C-Technical part 1-Presentation - Futuronix · Programming software : XBT L1001M, XBT L1003M (under Windows 98, 2000, and XP) Uni-Telway Modbus Uni-Telway Modbus Modbus. C-Technical

C-Technical part1- Presentation

C -1 Technical part/30

CUSTOMER VIEW- XBT N-JLD

06-2003

Create your pages

Use this icon to create an alphanumeric fieldthan follow the assistant.

1 2 3

XBTL1000 Reminder1.51.5