Bus Emissions Reduction on Putney High Street
Claire Cheriyan, on behalf of Finn Coyle
Principal Analyst (Emissions Modelling and Monitoring)
2
Pollution in Putney
Source Apportionment for NOx on Putney High St
3
SCR Roll-out
4
Route Selection
NO2 Focus Areas
NOx Abatement Retrofit £10 million funding (DfT/TfL) to retrofit approx 1000 Euro III buses with SCR
1015 buses now fitted to 3 types of Euro III bus
NOx reacts with ammonia over the catalyst and reduces it to nitrogen and water
(NO and NO2) + NH3 N2 + H2ON2O + NH3 (Secondary Emissions)
95 out of 220 buses that use Putney High Street were retrofitted with SCR
This made Putney the ideal location for monitoring the effectiveness of SCR programme
5
Calculating the effectiveness of SCR• TfL developed with Millbrook a ‘real world’ drive cycle based on Route 159
from Brixton to Oxford Street
• Real World test cycle with representative exhaust temperature essential forSCR development
0.00
10.00
20.00
30.00
40.00
50.00
60.00
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Spee
d (k
m/h
)
Test Time (secs)
SCR Emissions Test Results
7
NOx Reduction operating on Putney High Street
8
SCRT retrofit
base bus
0.0 2.5 5.0 7.5NO2 (g /kg fuel)
bus
type
Remote Sensing on Putney Hill - David Carslaw
• On average we see a 61% reduction in emissions of NO2
• 45% reduction in emissions of NOx
• These reductions are substantial compared with the average performance of the bus fleet in London including OEM SCR systems
SCRT retrofit
base bus
0 10 20 30NOx (g /kg fuel)
bus
type
0.00
0.01
0.02
0.03
0.04
0.05
0 20 40 60NOx (g/kg fuel)
dens
ity
busSCRT retrofit
base bus
SCR inlet temperature (deg. C)
RS
D N
Ox/C
O2 r
atio
0.000
0.005
0.010
0.015
150 200 250 300 350
●
●
●●
●
● ●●●●●●●●●●●●
●
●●●●●●●●●●●●●●●●●●●●●●●●
●●●
●
●●●
●●●●●●●●●●●●●●●●●●●●
●
● ●
●●●●●●●●●●●●●●●●●●●●●●●●●●●●
●
●
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●● ● ●●●
●●●●●●●●●●
●
speed
(km hr1)
5
10
15
20
25
30
35
40
• Emissions distribution– SCRT buses sometimes behave like
base buses– Other times there is ~90%
reduction in NOx
• Test track results– Importance of SCR inlet
temperature– >200oC gives 90% reduction in NOx
• Expect greater reduction in NOx where engine runs hotter
Monitoring Scheme Effectiveness – Putney High St
“there were 42% and 71% fewer exceedences at the kerb and façade respectively in the second half
of 2013 when compared to the second half of 2010 to 2012”
“a sustained decrease in ambient NO2 concentrations of 16% (during normalised
meteorological conditions) at the façade is an encouraging result”
10
Putney High St NO2 Monitor Trends
11
Summary and Conclusions
• The SCR Retrofit Programme has been successful in reducing NO2 concentrations on Putney High Street
• Euro VI and 3rd Generation SCR systems offer the potential for further savings going forward
12