26
Data ONTAP® 7.2 Brocade 3000 Series Switch Configuration Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP Documentation comments: [email protected] Information Web: http://www.netapp.com Part number 215-03781_A0 Updated for Data ONTAP 7.2.5 on 5 May 2008

Brocade 3000 Swconfig

Embed Size (px)

Citation preview

Page 1: Brocade 3000 Swconfig

Data ONTAP® 7.2 Brocade 3000 SeriesSwitch Configuration Guide

NetApp, Inc.495 East Java DriveSunnyvale, CA 94089 U.S.A.Telephone: +1 (408) 822-6000Fax: +1 (408) 822-4501Support telephone: +1 (888) 4-NETAPPDocumentation comments: [email protected] Web: http://www.netapp.com

Part number 215-03781_A0Updated for Data ONTAP 7.2.5 on 5 May 2008

Page 2: Brocade 3000 Swconfig

Copyright and trademark information

Copyright information

Copyright © 1994–2008 NetApp, Inc. All rights reserved. Printed in the U.S.A.

No part of this document covered by copyright may be reproduced in any form or by any means—graphic, electronic, or mechanical, including photocopying, recording, taping, or storage in an electronic retrieval system—without prior written permission of the copyright owner.

Portions of this product are derived from the Berkeley Net2 release and the 4.4-Lite-2 release, which are copyrighted and publicly distributed by The Regents of the University of California. Copyright © 1980–1995 The Regents of the University of California. All rights reserved.

Portions of this product are derived from NetBSD, copyright © Carnegie Mellon University. Copyright © 1994, 1995 Carnegie Mellon University. All rights reserved. Author Chris G. Demetriou.

Permission to use, copy, modify, and distribute this software and its documentation is hereby granted, provided that both the copyright notice and its permission notice appear in all copies of the software, derivative works or modified versions, and any portions thereof, and that both notices appear in supporting documentation.

CARNEGIE MELLON ALLOWS FREE USE OF THIS SOFTWARE IN ITS “AS IS” CONDITION. CARNEGIE MELLON DISCLAIMS ANY LIABILITY OF ANY KIND FOR ANY DAMAGES WHATSOEVER RESULTING FROM THE USE OF THIS SOFTWARE.

Software derived from copyrighted material of The Regents of the University of California and Carnegie Mellon University is subject to the following license and disclaimer:

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

1. Redistributions of source code must retain the above copyright notices, this list of conditions, and the following disclaimer.

2. Redistributions in binary form must reproduce the above copyright notices, this list of conditions, and the following disclaimer in the documentation and/or other materials provided with the distribution.

3. All advertising materials mentioning features or use of this software must display this text:

This product includes software developed by the University of California, Berkeley and its contributors.

4. Neither the name of the University nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.

THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

ii Copyright and trademark information

Page 3: Brocade 3000 Swconfig

This software contains materials from third parties licensed to NetApp, Inc. which is sublicensed, and not sold, and title to such material is not passed to the end user. All rights reserved by the licensors. You shall not sublicense or permit timesharing, rental, facility management or service bureau usage of the Software.

Portions developed by the Apache Software Foundation (http://www.apache.org/). Copyright © 1999 The Apache Software Foundation.

Portions Copyright © 1995–1998, Jean-loup Gailly and Mark AdlerPortions Copyright © 2001, Sitraka Inc.Portions Copyright © 2001, iAnywhere SolutionsPortions Copyright © 2001, i-net software GmbHPortions Copyright © 1995 University of Southern California. All rights reserved.

Redistribution and use in source and binary forms are permitted provided that the above copyright notice and this paragraph are duplicated in all such forms and that any documentation, advertising materials, and other materials related to such distribution and use acknowledge that the software was developed by the University of Southern California, Information Sciences Institute. The name of the University may not be used to endorse or promote products derived from this software without specific prior written permission.

Portions of this product are derived from version 2.4.11 of the libxml2 library, which is copyrighted by the World Wide Web Consortium. NetApp modified the libxml2 software on December 6, 2001, to enable it to compile cleanly on Windows, Solaris, and Linux. The changes have been sent to the maintainers of libxml2. The unmodified libxml2 software can be downloaded from http://www.xmlsoft.org/.

Copyright © 1994–2002 World Wide Web Consortium, (Massachusetts Institute of Technology, Institut National de Recherche en Informatique et en Automatique, Keio University). All Rights Reserved. http://www.w3.org/Consortium/Legal/

Software derived from copyrighted material of the World Wide Web Consortium is subject to the following license and disclaimer:

Permission to use, copy, modify, and distribute this software and its documentation, with or without modification, for any purpose and without fee or royalty is hereby granted, provided that you include the following on ALL copies of the software and documentation or portions thereof, including modifications, that you make:

The full text of this NOTICE in a location viewable to users of the redistributed or derivative work.

Any pre-existing intellectual property disclaimers, notices, or terms and conditions. If none exist, a short notice of the following form (hypertext is preferred, text is permitted) should be used within the body of any redistributed or derivative code: “Copyright © [$date-of-software] World Wide Web Consortium, (Massachusetts Institute of Technology, Institut National de Recherche en Informatique et en Automatique, Keio University). All Rights Reserved. http://www.w3.org/Consortium/Legal/”

Notice of any changes or modifications to the W3C files, including the date changes were made.

THIS SOFTWARE AND DOCUMENTATION IS PROVIDED “AS IS,” AND COPYRIGHT HOLDERS MAKE NO REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE OR THAT THE USE OF THE SOFTWARE OR DOCUMENTATION WILL NOT INFRINGE ANY THIRD PARTY PATENTS, COPYRIGHTS, TRADEMARKS OR OTHER RIGHTS.

COPYRIGHT HOLDERS WILL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF ANY USE OF THE SOFTWARE OR DOCUMENTATION.

Copyright and trademark information iii

Page 4: Brocade 3000 Swconfig

The name and trademarks of copyright holders may NOT be used in advertising or publicity pertaining to the software without specific, written prior permission. Title to copyright in this software and any associated documentation will at all times remain with copyright holders.

Software derived from copyrighted material of NetApp, Inc. is subject to the following license and disclaimer:

NetApp reserves the right to change any products described herein at any time, and without notice. NetApp assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by NetApp. The use or purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of NetApp.

The product described in this manual may be protected by one or more U.S.A. patents, foreign patents, or pending applications.

RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by the government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.277-7103 (October 1988) and FAR 52-227-19 (June 1987).

Trademark information

NetApp, the Network Appliance logo, the bolt design, NetApp—the Network Appliance Company, DataFabric, Data ONTAP, FAServer, FilerView, FlexClone, FlexVol, Manage ONTAP, MultiStore, NearStore, NetCache, NOW NetApp on the Web, SecureShare, SnapDrive, SnapLock, SnapManager, SnapMirror, SnapMover, SnapRestore, SnapValidator, SnapVault, Spinnaker Networks, SpinCluster, SpinFS, SpinHA, SpinMove, SpinServer, StoreVault, SyncMirror, Topio, VFM, and WAFL are registered trademarks of NetApp, Inc. in the U.S.A. and/or other countries. Cryptainer, Cryptoshred, Datafort, and Decru are registered trademarks, and Lifetime Key Management and OpenKey are trademarks, of Decru, a NetApp, Inc. company, in the U.S.A. and/or other countries. SANScreen is a registered trademark of Onaro, Inc., a NetApp, Inc. company, in the U.S.A. and/or other countries. gFiler, Network Appliance, SnapCopy, Snapshot, and The evolution of storage are trademarks of NetApp, Inc. in the U.S.A. and/or other countries and registered trademarks in some other countries. The NetApp arch logo; the StoreVault logo; ApplianceWatch; BareMetal; Camera-to-Viewer; ComplianceClock; ComplianceJournal; ContentDirector; ContentFabric; EdgeFiler; FlexShare; FPolicy; Go Further, Faster; HyperSAN; InfoFabric; LockVault; NOW; ONTAPI; RAID-DP; ReplicatorX; RoboCache; RoboFiler; SecureAdmin; Serving Data by Design; SharedStorage; Simplicore; Simulate ONTAP; Smart SAN; SnapCache; SnapDirector; SnapFilter; SnapMigrator; SnapSuite; SohoFiler; SpinMirror; SpinRestore; SpinShot; SpinStor; vFiler; VFM Virtual File Manager; VPolicy; and Web Filer are trademarks of NetApp, Inc. in the U.S.A. and other countries. NetApp Availability Assurance and NetApp ProTech Expert are service marks of NetApp, Inc. in the U.S.A.

IBM, the IBM logo, AIX, and System Storage are trademarks and/or registered trademarks of International Business Machines Corporation.

Apple is a registered trademark and QuickTime is a trademark of Apple, Inc. in the U.S.A. and/or other countries. Microsoft is a registered trademark and Windows Media is a trademark of Microsoft Corporation in the U.S.A. and/or other countries. RealAudio, RealNetworks, RealPlayer, RealSystem, RealText, and RealVideo are registered trademarks and RealMedia, RealProxy, and SureStream are trademarks of RealNetworks, Inc. in the U.S.A. and/or other countries.

All other brands or products are trademarks or registered trademarks of their respective holders and should be treated as such.

NetApp, Inc. is a licensee of the CompactFlash and CF Logo trademarks.

NetApp, Inc. NetCache is certified RealSystem compatible.

iv Copyright and trademark information

Page 5: Brocade 3000 Swconfig

Table of Contents

Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii

Chapter 1 Brocade MetroCluster Overview . . . . . . . . . . . . . . . . . . . . . . . . 1

Brocade 3000 series MetroCluster . . . . . . . . . . . . . . . . . . . . . . . . 2

Chapter 2 Brocade Switch Cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Cabling a Brocade 3000 series switch . . . . . . . . . . . . . . . . . . . . . . 6

Brocade 3000 series switches. . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Chapter 3 Brocade 3000 Series Switch Configuration . . . . . . . . . . . . . . . . . . 9

Configuring Brocade switches . . . . . . . . . . . . . . . . . . . . . . . . . 10

Completing the configuration. . . . . . . . . . . . . . . . . . . . . . . . . . 13

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Table of Contents v

Page 6: Brocade 3000 Swconfig

vi Table of Contents

Page 7: Brocade 3000 Swconfig

Preface

About this guide This guide describes how Brocade 3000 series switch models operate with a Met-

roCluster, how to configure a Brocade switch in a fabric-attached MetroCluster,

and how to set up a fabric-attached MetroCluster.

Audience This guide is for system administrators who are familiar with operating systems

that run on the storage system’s clients, such as UNIX®, Linux®, and Windows® 2003. It also assumes that you are familiar with how to configure the storage system and how the NFS, CIFS, and HTTP protocols are used for file sharing or transfers. This guide does not cover basic system or network administration topics, such as IP addressing, routing, and network topology; it emphasizes the characteristics of the storage system.

Terminology Storage systems that run Data ONTAP® are sometimes also referred to as appliances, storage appliances, or systems. The name of the graphical user interface for Data ONTAP (FilerView) reflects one of these common usages.

FilerView as an alternative to commands

As a storage system administrator, you can perform tasks by entering commands at the console, in configuration files, or through a Telnet session or Remote Shell connection.

Another method of performing common tasks is to use the FilerView® graphical management interface for viewing and managing a storage system from a Web browser. FilerView is easy to use, and it includes Help that explains FilerView features and how to use them.

For more information about accessing a storage system using FilerView, and about FilerView Help, see the Storage Management Guide.

Command conventions

You can enter storage system commands on the system console or from any client that can obtain access to the storage system using a Telnet session. In examples that illustrate commands executed on a UNIX workstation, the command syntax and output might differ, depending on your version of UNIX.

Preface vii

Page 8: Brocade 3000 Swconfig

Formatting conventions

The following table lists different character formats used in this guide to set off special information.

Keyboard conventions

This guide uses capitalization and some abbreviations to refer to the keys on the keyboard. The keys on your keyboard might not be labeled exactly as they are in this guide.

Formatting convention Type of information

Italic type ◆ Words or characters that require special attention.

◆ Placeholders for information you must supply. For example, if the guide requires you to enter the fctest adaptername command, you enter the characters “fctest” followed by the actual name of the adapter.

◆ Book titles in cross-references.

Monospaced font ◆ Command and daemon names.

◆ Information displayed on the system console or other computer monitors.

◆ The contents of files.

Bold monospaced font

Words or characters you type. What you type is always shown in lowercase letters, unless your program is case-sensitive and uppercase letters are necessary for it to work properly.

What is in this guide… What it means…

hyphen (-) Used to separate individual keys. For example, Ctrl-D means holding down the Ctrl key while pressing the D key.

Enter Used to refer to the key that generates a carriage return; the key is named Return on some keyboards.

type Used to mean pressing one or more keys on the keyboard.

enter Used to mean pressing one or more keys and then pressing the Enter key.

viii

Page 9: Brocade 3000 Swconfig

Special messages This guide contains special messages that are described as follows:

NoteA note contains important information that helps you install or operate the system efficiently.

AttentionAn attention notice contains instructions that you must follow to avoid damage to the equipment, a system crash, or loss of data.

Preface ix

Page 10: Brocade 3000 Swconfig

x

Page 11: Brocade 3000 Swconfig

Chapter 1: Brocade MetroCluster Overview

1

Brocade MetroCluster Overview

About this chapter This chapter describes a Brocade switch MetroCluster and defines a switch fabric.

Topics in this chapter

This chapter discusses the following topic:

◆ “Description of a MetroCluster configuration” on page 2

1

Page 12: Brocade 3000 Swconfig

Brocade 3000 series MetroCluster

Description of a MetroCluster configuration

The MetroCluster configuration uses two storage systems that are connected to provide high availability and data mirroring.You can place these systems in different locations. When the distance between the two systems is greater than 500 meters, use four Brocade Fibre Channel switches in a fabric configuration to connect the two systems. This configuration is called a fabric-attached MetroCluster.

Switch fabrics A fabric-attached MetroCluster contains two switch fabrics. A switch fabric consists of a switch on the local half of the cluster connected to a switch on the remote half of the cluster. The two switches are connected to each other through long-distance Inter-Switch Link (ISL) cables, as shown in the following diagram.

For example, consider a MetroCluster configuration in which the first fabric begins at Switch 1 on the local node and is completed by connecting the ISL cable to the first switch (Switch 3) on the remote node. The second fabric is created using Switch 2 on the local node, connected through a second ISL cable to the second switch (Switch 4) on the remote node.

NoteEach fabric supports only one ISL.

2 Brocade 3000 series MetroCluster

Page 13: Brocade 3000 Swconfig

Dual Fabric Metro Cluster

Fabric 1

Fabric 2

SW2 SW4

SW3SW1

Chapter 1: Brocade MetroCluster Overview 3

Page 14: Brocade 3000 Swconfig

4 Brocade 3000 series MetroCluster

Page 15: Brocade 3000 Swconfig

Chapter 2: Brocade Switch Cabling

2

Brocade Switch Cabling

About this chapter This chapter illustrates how to cable Brocade 3000 series switches.

Topics in this chapter

This chapter discusses the following topics:

◆ “Cabling a Brocade 3000 series switch” on page 6

◆ “Brocade 3000 series switches” on page 8

5

Page 16: Brocade 3000 Swconfig

Cabling a Brocade 3000 series switch

Diagram of a Brocade switch cabled through the switch fabric

The following illustration shows how the local storage system and the remote storage system are cabled together through the switch fabric. This diagram is for storage systems that support hardware-based disk ownership.

Pool0

LocalShelf

1

Out In

In Out

AB

Pool0

LocalShelf

2

Out In

In Out

AB

Pool1

RemoteShelf 1Mirror

Out In

In Out

AB

Pool1

RemoteShelf 2Mirror

Out In

In Out

AB

Pool0

LocalShelf

1

Out In

In Out

AB

Pool0

LocalShelf

2

Out In

In Out

AB

Pool1

RemoteShelf 1Mirror

Out In

In Out

AB

Pool1

RemoteShelf 2Mirror

Out In

In Out

AB

SW1

Pool0

1

10 2 3 98 10 11

54 6 7 1312 14 15

SW3

SW2 SW4

LongHaulFC

Equipment

Local Node Remote Node

Pool0

1

10 2 3 98 10 11

54 6 7 1312 14 15

Pool0

1

10 2 3 98 10 11

54 6 7 1312 14 15

Pool0

1

10 2 3 98 10 11

54 6 7 1312 14 15

6 Cabling a Brocade 3000 series switch

Page 17: Brocade 3000 Swconfig

Switch banks and quadrants

The Fibre Channel switches are divided into banks and quadrants. Each switch has two banks, that divide the switch into two equal parts. (See the switch illustrations that follow.)

The banks are further divided into two quadrants of two or four ports each (depending on the number of ports in the switch). These quadrants combine to form pools, which function the same way in a fabric-attached MetroCluster as in a mirrored cluster. Quadrants 1 and 3 belong to Pool 0, and Quadrants 2 and 4 belong to Pool 1. Each switch bank contains a Pool 0 and a Pool 1.

Chapter 2: Brocade Switch Cabling 7

Page 18: Brocade 3000 Swconfig

Brocade 3000 series switches

Switches in the Brocade 3000 series

The Brocade 3000 series of switches includes the Brocade 3800 and 3850 switches and the Brocade 3200 and 3250 switches.

16-port switches The Brocade 3800 and 3850 switches are 16-port switches and have ports 0 through 15 licensed and operational, as shown in the following 16-port switch illustration.

8-port switches The Brocade 3200 and 3250 switches are 8-port switches and have eight ports, as shown in the following illustration.

8 Brocade 3000 series switches

Page 19: Brocade 3000 Swconfig

Chapter 3: Brocade 3000 Series Switch Configuration

3

Brocade 3000 Series Switch Configuration

About this chapter This chapter contains configuration information for the Brocade 3000 series switches.

Topics in this chapter

This chapter discusses the following topics:

◆ “Configuring Brocade switches” on page 10

◆ “Completing the configuration” on page 13

9

Page 20: Brocade 3000 Swconfig

Configuring Brocade switches

Points to know before you begin

To configure a Brocade 3000 series switch for a fabric-attached MetroCluster configuration, complete the following procedures.

NoteYou must perform these procedures on each switch in the MetroCluster configuration.

Use these procedures instead of the switch configuration procedure in the Cluster Installation and Administration Guide or the Active/Active Configuration Installation and Administration Guide.

Configuring a switch

To configure a switch, complete the following steps.

Step Action

1 If this switch has not been configured before, log in to the switch, using the console port and your Windows HyperTerminal application (not available in Windows Vista versions), and set the following values, as described in the Brocade switch hardware reference manual for your switch:

◆ IP address

◆ Default account passwords (administrtor and user)

◆ Date and time

NoteUse the Telnet command for subsequent switch login sessions, using the switch IP address.

10 Configuring Brocade switches

Page 21: Brocade 3000 Swconfig

2 Display the licenses installed on the switch by entering the following command:

licenseshow

Result: You should have the following licenses:

◆ Fabric License (or two Domain Licenses)

◆ Extended Fabric License (for ISL distances over 10 km)

If you do not have these licenses, contact your sales representative before proceeding.

3 Set the switch name, if needed, by entering the following command:

switchname switch_name

NoteUse a name that is meaningful, such as node name and switch.

4 Determine the switch firmware by entering the following command:

version

Result: The currently installed switch firmware is displayed.

5 Access the MetroCluster Compatibility Matrix on the NOW (NetApp on the Web)® site at now.netapp.com to get the currently supported version of the switch firmware.

NoteYou can find this document under the Interoperability heading on the Product Documentation page.

6 If your switch firmware is not the supported version, complete the following steps:

a. Download the switch firmware from now.netapp.com and install it, as described in the Brocade switch hardware reference manual for your switch.

b. Reboot the switch.

Step Action

Chapter 3: Brocade 3000 Series Switch Configuration 11

Page 22: Brocade 3000 Swconfig

Setting the switch parameters

After configuring the switch, set the switch parameters by completing the following steps.

1 Disable the switch by entering the following command:

switchdisable

2 Clear any preexisting configuration by entering the following commands:

cfgclear

cfgdisable

cfgsave

3 Configure the switch with default settings by entering the following command:

configdefault

4 Set the switch parameters by entering the following command:

configure

NoteThe domain ID might be specified by your system administrator. If not, you can use any unique number, for example, 1, 2, 3, or 4.

You should set only the following parameters:

◆ Fabric parameters = y

❖ Domain_id = XXX

❖ Disable device probing = 1

◆ Arbitrated Loop parameters = y

❖ Send FAN frames = 0

12 Configuring Brocade switches

Page 23: Brocade 3000 Swconfig

Completing the configuration

Completing the switch configuration

After the parameters are set, complete the configuration by performing these steps.

1 After you have set the parameters listed in Step 4 in “Setting the switch parameters” on page 12, exit the configuration utility by entering the following command:

ctrl-d

2 Reboot the switch so that the new settings take effect, by entering the following command:

fastboot

3 Log in to the switch and disable the switch by entering the following command:

switchdisable

4 For all switches in the Brocade 3000 series (3800, 3850, 3200, and 3250), set all ports attached to disk loops to half duplex by entering the following command for each port number:

NotePerform this command only for the ports to which disks are attached. Do not set ports attached to disk loops to Locked L-Port.

portCfgLPort <disk_port>,0,0,1

5 For the Brocade 3200 and 3250 switches, ensure that the disk loop port is showing ON in the Locked Loop HD fields only by entering the following commands:

portCfgShow

portCfglport

Result: ON is displayed in the locked Loop HD fields only.

NoteThese commands do not work with the Brocade 3800 and 3850 switches.

Chapter 3: Brocade 3000 Series Switch Configuration 13

Page 24: Brocade 3000 Swconfig

6 If your switch has the trunking license installed, disable trunking on the ISL port by entering the following command:

portcfgtrunkport <ISL_port#> 0

7 To configure the long-distance ISL port for your ISL length, enter the following command:

portcfglongdistance [slotnumber/portnumber][distance_level] [VC_Translation_Link_Init][desired_distance]

distance_level is one of the following values:

◆ As a normal switch port, use LO.

◆ For distances up to 10 km, use LE.

◆ For distances beyond 10 km, use LS. Specify 1 to activate long- distance link initialization sequence, or specify 0 to deactivatethis mode. Then specify the distance.

Example: If your ISL length is 18 km, and your ISL is connected to port 13, you would use the following command:

portCfgLongDistance 13 LS 1 18

8 To enable the switch, enter the following command:

switchenable

9 To verify that the switch settings are correct, enter the following command:

configshow

14 Completing the configuration

Page 25: Brocade 3000 Swconfig

Index

Numerics16-port switch 83000 series switch 103800 switch 83850 switch 8

Aaudience, intended for this book vii

Bbanks 7Brocade 3200 8Brocade Fibre Channel switches 2

Ccommands

configshow 14configure 12switchdisable 12switchenable 14switchname 11version 11

configurationcompleting 13

conventionscommand viiformatting viiikeyboard viii

Ddefault settings 12disabling the switch 13disk loops 13disks 13domain ID 12

EExtended Fabric License 11

FFabric License 11fabric-attached MetroCluster 7FilerView vii

Hhalf duplex 13

IISL (Inter-Switch Link) cables 2ISL length 14

Llong-distance ISL port 14

MMetroCluster

configuring the switches in 9description 2fabric-attached 2

Nnode name 11

Pparameters 12, 13pools 7port number 13ports 7, 13

Qquadrants 7

Sspecial messages ix

Index 15

Page 26: Brocade 3000 Swconfig

switch fabric 2switch firmware 11switch parameters 12switch settings 14switches

banks 7checking firmware revision 11configuring for MetroCluster 9disabling 12

pools 7quadrants 7setting the parameters 12

system administrator 12

Tterminology viitrunking license 14

16 Index