72
Bracing Systems Bracing Systems 1

Bracing Systems Product/Product PD… · •• Most economical bracing system 23 Eave Floor Notes about Diagonal Rod Bracing: Diagonal Rods 24. Diagonal Rods 25. Diagonal Bracing

  • Upload
    others

  • View
    20

  • Download
    0

Embed Size (px)

Citation preview

Bracing SystemsBracing Systems

11

Rod BracingRod Bracing

22

Wind Bracing SystemsWind Bracing Systems

33

HOWBRACINGWORKS

Wind Bracing SystemsWind Bracing SystemsWind Bracing SystemsWind Bracing Systems

44

Load Dispersal

The WIND load on Endwall panels...

Wind Bracing SystemsWind Bracing SystemsWind Bracing SystemsWind Bracing Systems

55

Load Dispersal

is dispersed through Endwall framing...

Wind Bracing SystemsWind Bracing SystemsWind Bracing SystemsWind Bracing Systems

66

Load Dispersal

into the Continuous Purlin system.

Wind Bracing SystemsWind Bracing SystemsWind Bracing SystemsWind Bracing Systems

77

Load Dispersal

The Purlins transfer the load...

Wind Bracing SystemsWind Bracing SystemsWind Bracing SystemsWind Bracing Systems

88

Load Dispersal

into the roof Brace Rods.

Wind Bracing SystemsWind Bracing SystemsWind Bracing SystemsWind Bracing Systems

99

Load Dispersal

The load travels through the Roof bracing...

Wind Bracing SystemsWind Bracing SystemsWind Bracing SystemsWind Bracing Systems

1010

Load Dispersal

through the Eave Purlin ...

Wind Bracing SystemsWind Bracing SystemsWind Bracing SystemsWind Bracing Systems

1111

Load Dispersal

to the wall Diagonal Bracing ...

Wind Bracing SystemsWind Bracing SystemsWind Bracing SystemsWind Bracing Systems

1212

Load Dispersal

...(or auxiliary bracing)...

Wind Bracing SystemsWind Bracing SystemsWind Bracing SystemsWind Bracing Systems

1313

Load Dispersal

into the Building’s foundation.

Wind Bracing SystemsWind Bracing SystemsWind Bracing SystemsWind Bracing Systems

1414

Load Dispersal

into the Building’s foundation.

Transverse (PerpendicularTransverse (Perpendicularto Sidewall)to Sidewall)

1515

Longitudinal (PerpendicularLongitudinal (Perpendicularto Endwall)to Endwall)

1616

Standard EP LocationStandard EP Location

1717

Roof Rods Break at Endpost(s)Roof Rods Break at Endpost(s)

1818

Wind BracingWind Bracing

1919

If possible, keep endpost spacingIf possible, keep endpost spacingsimilarsimilar at each endwall for a moreat each endwall for a more

efficient bracing pattern.efficient bracing pattern.

Typical Rod Bracing LocationTypical Rod Bracing Location

2020

Wind Bracing SystemsWind Bracing SystemsWind Bracing SystemsWind Bracing Systems

StandardStandardBracingBracingMethodsMethods

2121

Diagonal BracingDiagonal BracingDiagonal BracingDiagonal Bracing

•• VP standard bracing utilizes DiagonalVP standard bracing utilizes DiagonalBracing in the Roof and Walls.Bracing in the Roof and Walls.

•• The bracing design is determined by:The bracing design is determined by:

Building Loads & CodeBuilding Loads & Code

Building SizeBuilding Size

Building LocationBuilding Location

2222

Diagonal Rod BracingDiagonal Rod BracingDiagonal Rod BracingDiagonal Rod Bracing

•• Stiffest bracing system availableStiffest bracing system available•• Most economical bracing systemMost economical bracing system

2323

Eave

Floor

Notes about Diagonal Rod Bracing:

Diagonal RodsDiagonal Rods

2424

Diagonal RodsDiagonal Rods

2525

Diagonal Bracing OptionsDiagonal Bracing Options(Rods)(Rods)

Diagonal Bracing OptionsDiagonal Bracing Options(Rods)(Rods)

2626

Eave

Floor

Alternate Diagonal BracingAlternate Diagonal Bracing

2727

Rod Brace AssemblyRod Brace Assembly

2828

Coupling NutsCoupling Nuts

2929

Angle BracingAngle Bracing

Bracing may be single rods orBracing may be single rods orangles depending uponangles depending uponloading/designloading/design

3030

Angle BracingAngle Bracing

3131

Angle BracingAngle Bracing

3232

Angle BracingAngle Bracing

3333

Wind Bracing SystemsWind Bracing SystemsWind Bracing SystemsWind Bracing Systems

AlternativeAlternativeBracingBracingMethodsMethods

3434

Alternative Bracing MethodsAlternative Bracing MethodsAlternative Bracing MethodsAlternative Bracing Methods

Torsional BracingTorsional Bracing

3535

Rods are omitted from one sidewall.

Torsional BracingTorsional Bracing

3636

No Torsional Allowed if…No Torsional Allowed if…

3737

Alternative Bracing MethodsAlternative Bracing MethodsAlternative Bracing MethodsAlternative Bracing Methods

•• InexpensiveInexpensive•• Maximum building width of 50’Maximum building width of 50’•• Maximum eave height of 18’Maximum eave height of 18’•• 100 mph maximum wind speed100 mph maximum wind speed•• Minimum 3 baysMinimum 3 bays•• Call your Service Center ifCall your Service Center if closeclose to theseto theseparametersparameters

3838

Notes About Torsional Bracing

Rod Brace to FloorRod Brace to Floor

3939

Rod Mark NumbersRod Mark Numbers

4040

Alternative Bracing MethodsAlternative Bracing MethodsAlternative Bracing MethodsAlternative Bracing Methods

••Portal BeamPortal Beam••Knee BracesKnee Braces••Additional columnAdditional column

supportsupport

4141

Portal BracingPortal Brace Includes:

Portal BracingPortal Bracing

4242

Portal BracingPortal Bracing

4343

4444

BracingBracingNew Bracing OptionNew Bracing Option•• Fixed Base Wind Post (withFixed Base Wind Post (with

automated Wind Post Baseautomated Wind Post BasePlate Design)Plate Design)

•• Use at sidewalls or endwallsUse at sidewalls or endwalls•• 35’35’--0” max. eave height0” max. eave height•• Max. 24” column depthMax. 24” column depth•• Connection at main frame isConnection at main frame is

similar to that of portal framesimilar to that of portal frame

44

BracingBracing--Wind PostsWind Posts

Post and Beam StabilityPost and Beam Stability

Automated diaphragm checkAutomated diaphragm checkIf fails Rods may automatically beIf fails Rods may automatically bedesigneddesignedInitially at interior bayInitially at interior bayThen atThen at endbayendbay

4545

Post and Beam StabilityPost and Beam Stability

4646

Alternative Bracing MethodsAlternative Bracing MethodsAlternative Bracing MethodsAlternative Bracing Methods

••More expensive than rodMore expensive than rod••Flexible, not as stiff as diagonalFlexible, not as stiff as diagonalbracingbracing••Maximum eave height of 20’Maximum eave height of 20’••Special clearances possibleSpecial clearances possible

4747

Notes About Portal Bracing

Portal BracingPortal Bracing

4848

Portal BracingPortal Bracing

4949

Portal Bracing???Portal Bracing???

5050

Alternative Bracing MethodsAlternative Bracing MethodsAlternative Bracing MethodsAlternative Bracing Methods

•• Portal Frame BeamPortal Frame Beam•• Portal Frame ColumnsPortal Frame Columns•• Load Transfer ClipsLoad Transfer Clips•• Bolts and NutsBolts and Nuts

5151

Portal Frame Includes:

Portal Frames

Portal FramePortal Frame

5252

Portal Frame (1/2” offset)Portal Frame (1/2” offset)

5353

Portal FramePortal Frame

5454

Portal FramePortal Frame

5555

Alternative Bracing MethodsAlternative Bracing MethodsAlternative Bracing MethodsAlternative Bracing Methods

•• More expensive than rodsMore expensive than rods•• Relatively stiffRelatively stiff (can hold drift on frame)(can hold drift on frame)

•• Special clearances possibleSpecial clearances possible(Hold column & rafter depths)(Hold column & rafter depths)

5656

Notes About Portal Frames

Portal Frame

5757

Portal FramePortal Frame(typical Anchor Rod Detail)(typical Anchor Rod Detail)

5858

Combination of Rods and Portal Frame•• May be more for building heightsMay be more for building heightsabove 20’ tall.above 20’ tall.

5959

Alternative Bracing MethodsAlternative Bracing MethodsAlternative Bracing MethodsAlternative Bracing MethodsEave

Floor

Partial Height Portal FramePartial Height Portal Frame

6060

Bracing ComparisonsBracing Comparisons(Building Size = 200 x 300 x 19, IBC, 85 MPH(Building Size = 200 x 300 x 19, IBC, 85 MPH

WindWind -- Book Price Shown)Book Price Shown)

6161

$0$1,000$2,000$3,000$4,000$5,000$6,000$7,000$8,000

Bracing Type

RodsPortal BracePortal Frame

Strut Bracing at WallStrut Bracing at Wall

6262

Tube StrutTube Strut

6363

Rod Bracing at Truss FrameRod Bracing at Truss Frame

6464

Rod Bracing at Truss FrameRod Bracing at Truss Frame

6565

Rod Bracing at FacadeRod Bracing at Facade

6666

No Bracing?!?!?!No Bracing?!?!?!No Bracing?!?!?!No Bracing?!?!?!

6767

•• As erection proceeds all Brace Rods,As erection proceeds all Brace Rods,Flange Braces, Struts, Purlin/Girt LapsFlange Braces, Struts, Purlin/Girt Lapsshould be installed before proceeding.should be installed before proceeding.

•• All buildings will require someAll buildings will require sometemporary bracing until all erection istemporary bracing until all erection iscomplete !complete ! Do NOT take any chances !Do NOT take any chances !

6868

6969

What Wind Can Do!What Wind Can Do!

7070

Bracing TipsBracing Tips

Bracing most effective atBracing most effective at 45 degree45 degreeangleangleDiagonal bracingDiagonal bracing always mostalways mosteconomicaleconomicalConsiderConsider Interior Column BracingInterior Column Bracingat wide buildingsat wide buildingsConsider “Consider “shear wallsshear walls” with masonry,” with masonry,etc.etc.

7171

7272