13
2CDC 291 024 S0013 Data sheet Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and optocouplers are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC (programmable logic controller), PC or field bus systems and the sensor / actuator level. The compact design and different connection terminal possibilities optimize your panel installation. Characteristics Boxed slim relays and optocoupler modules, 6 mm or 12 mm 8 different rated control supply voltages: DC versions: 5 V, 12 V, 24 V AC/DC versions: 24 V, 48-60 V, 115 V, 230 V, 60-230 V Output relay: 1 n/c contact, 1 n/o contact, 1 c/o (SPDT) contact, 2 c/o (SPDT) contacts Output optocoupler: Transistor 100 mA - 58 V DC, MOS-FET 58 V DC - 2 A / 5 A, Triac 1 A - 400 V AC / 2 A - 230 V AC Devices with output contacts protected by built in RC circuit, which results in increased contact life Devices with leakage current protection on the input side All products with LED for the indication of the operational state Screw or spring-type terminals Jumper bars and separator end section as accessories Various certifications and approvals (see overview, document no. 2CDC117035D0201)

Boxed interface relays and optocouplers R600 Boxed slim ......Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and

  • Upload
    others

  • View
    29

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Boxed interface relays and optocouplers R600 Boxed slim ......Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and

2CD

C 2

91 0

24 S

0013

Data sheet

Boxed interface relays and optocouplers R600Boxed slim relays, optocouplers and accessories

Boxed interface relays and optocouplers are used

for electrical isolation, amplification and signal

matching between the electronic controlling, e.g.

PLC (programmable logic controller), PC or field

bus systems and the sensor / actuator level. The

compact design and different connection terminal

possibilities optimize your panel installation.

Characteristics – Boxed slim relays and optocoupler modules, 6 mm or 12 mm – 8 different rated control supply voltages:

DC versions: 5 V, 12 V, 24 V AC/DC versions: 24 V, 48-60 V, 115 V, 230 V, 60-230 V

– Output relay: 1 n/c contact, 1 n/o contact, 1 c/o (SPDT) contact, 2 c/o (SPDT) contacts Output optocoupler: Transistor 100 mA - 58 V DC, MOS-FET 58 V DC - 2 A / 5 A, Triac 1 A - 400 V AC / 2 A - 230 V AC

– Devices with output contacts protected by built in RC circuit, which results in increased contact life – Devices with leakage current protection on the input side – All products with LED for the indication of the operational state – Screw or spring-type terminals – Jumper bars and separator end section as accessories – Various certifications and approvals (see overview, document no. 2CDC117035D0201)

Page 2: Boxed interface relays and optocouplers R600 Boxed slim ......Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and

2 - Boxed interface relays and optocouplers R600 | Data sheet

Ordering details R600 interface relays - 1 n/c contact: 250 V, 10 mA - 6 A, width 12 mm Rated control supply voltage Connection type Particularities Type Order code Pkg

qtyWeight(1 pc)kg (lb)

24 V AC/DCScrew RC circuit parallel to

output contact

RB101R-24VUC 1SNA645019R04005 0.04

(0.088)Spring RBR101R-24VUC 1SNA645519R0600

Ordering details R600 interface relays - 1 n/o contact: 250 V, 10 mA - 6 A, width 6 mm Rated control supply voltage Connection type Particularities Type Order code Pkg

qtyWeight(1 pc)kg (lb)

24 V AC/DC Screw RB111-24VUC 1SNA645014R2700

10 0.02 (0.044)

115 V AC/DC Screw RB111-115VUC 1SNA645016R2100

230 V AC/DC Screw RB111-230VUC 1SNA645017R2200

24 V AC/DC Spring RBR111-24VUC 1SNA645514R2100

Ordering details R600 interface relays - 1 n/o contact: 250 V, 10 mA - 6 A, width 12 mm Rated control supply voltage Connection type Particularities Type Order code Pkg

qtyWeight(1 pc)kg (lb)

24 V AC/DCScrew RC circuit parallel to

output contactRB111R-24VUC 1SNA645018R0300

5 0.04 (0.088)Spring RBR111R-24VUC 1SNA645518R0500

Ordering details R600 interface relays - 1 c/o (SPDT) contact: 250 V, 10 mA - 6 A, width 6 mmRated control supply voltage Connection type Particularities Type Order code Pkg

qtyWeight(1 pc)kg (lb)

5 V DC Screw A1-A2 polarized RB121P-5VDC 1SNA645034R2300

10 0.02 (0.044)

12 V DC Screw A1-A2 polarized RB121P-12VDC 1SNA645035R2400

12 V DC Screw RB121-12VDC 1SNA645073R0000

24 V DC Screw RB121-24VDC 1SNA645071R0000

24 V AC/DC Screw RB121-24VUC 1SNA645001R0300

48-60 V AC/DC Screw RB121-48-60VUC 1SNA645002R0400

115 V AC/DC Screw RB121-115VUC 1SNA645003R0500

230 V AC/DC Screw RB121-230VUC 1SNA645004R0400

5 V DC Spring A1-A2 polarized RBR121P-5VDC 1SNA645534R2500

12 V DC Spring A1-A2 polarized RBR121P-12VDC 1SNA645535R2600

24 V DC Spring RBR121-24VDC 1SNA645571R0000

24 V AC/DC Spring RBR121-24VUC 1SNA645501R0500

48-60 V AC/DC Spring RBR121-48-60VUC 1SNA645502R0600

115 V AC/DC Spring RBR121-115VUC 1SNA645503R0700

230 V AC/DC Spring RBR121-230VUC 1SNA645504R0000

Ordering details R600 interface relays - 1 c/o (SPDT) contact: 250 V, 3 mA - 6 A, gold-plated contacts, width 6 mm Rated control supply voltage Connection type Particularities Type Order code Pkg

qtyWeight(1 pc)kg (lb)

5 V DC Screw A1-A2 polarized RB121PG-5VDC 1SNA645036R2500

10 0.02 (0.044)

12 V DC Screw RB121G-12VDC 1SNA645075R0000

24 V DC Screw RB121G-24VDC 1SNA645072R0000

24 V AC/DC Screw RB121G-24VUC 1SNA645005R0700

48-60 V AC/DC Screw RB121G-48-60VUC 1SNA645006R0000

115 V AC/DC Screw RB121G-115VUC 1SNA645007R0100

230 V AC/DC Screw RB121G-230VUC 1SNA645008R1200

24 V DC Spring RBR121G-24VDC 1SNA645572R0000

24 V AC/DC Spring RBR121G-24VUC 1SNA645505R0100

48-60 V AC/DC Spring RBR121G-48-60VUC 1SNA645506R0200

115 V AC/DC Spring RBR121G-115VUC 1SNA645507R0300

230 V AC/DC Spring RBR121G-230VUC 1SNA645508R1400

Page 3: Boxed interface relays and optocouplers R600 Boxed slim ......Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and

Data sheet | Boxed interface relays and optocouplers R600 - 3

Ordering details R600 interface relays - 1 c/o (SPDT) contact: 250 V, 10 mA - 6 A, width 12 mm Rated control supply voltage Connection type Particularities Type Order code Pkg

qtyWeight(1 pc)kg (lb)

60-230 V AC/DC Screw RB121-60-230VUC 1SNA645020R0100

5 0.04 (0.088)

115 V AC/DC Screw Leakage current protection, RC circuit parallel to input

RB121R-115VUC 1SNA645046R0700

230 V AC/DC Screw RB121R-230VUC 1SNA645011R2400

60-230 V AC/DC Spring RBR121-60-230VUC 1SNA645520R0300

230 V AC/DC Spring Leakage current protection, RC circuit parallel to input RBR121R-230VUC 1SNA645511R2600

Ordering details R600 interface relays - 2 c/o (SPDT) contacts: 250 V, 1 mA - 8 A, gold-plated contacts, width 12 mm Rated control supply voltage Connection type Type Order code Pkg

qtyWeight(1 pc)kg (lb)

24 V AC/DC Screw RB122G-24VUC 1SNA645012R2500

5 0.04 (0.088)

48-60 V AC/DC Screw RB122G-48-60VUC 1SNA645040R1500

115 V AC/DC Screw RB122G-115VUC 1SNA645041R0200

230 V AC/DC Screw RB122G-230VUC 1SNA645013R2600

24 V AC/DC Spring RBR122G-24VUC 1SNA645512R2700

48-60 V AC/DC Spring RBR122G-48-60VUC 1SNA645540R1700

115 V AC/DC Spring RBR122G-115VUC 1SNA645541R0400

230 V AC/DC Spring RBR122G-230VUC 1SNA645513R2000

Ordering details R600 optocouplers - Transistor output, 58 V DC, 100 mA, width 6 mm Rated control supply voltage Connection type Type Order code Pkg

qtyWeight(1 pc)kg (lb)

5 - 12 V DC Screw OBIC0100-5-12VDC 1SNA645047R0000

10 0.02 (0.044)

24 V DC Screw OBIC0100-24VDC 1SNA645021R2600

48 - 60 V AC/DC Screw OBIC0100-48-60VUC 1SNA645049R1200

115 - 230 V AC/DC Screw OBIC0100-115-230 1SNA645022R2700

5 - 12 V DC Spring OBRIC0100-5-12VDC 1SNA645547R0200

24 V DC Spring OBRIC0100-24VDC 1SNA645521R2000

48 - 60 V AC/DC Spring OBRIC0100-48-60VUC 1SNA645549R1400

115 - 230 V AC/DC Spring OBRIC0100-115-230 1SNA645522R2100

Ordering details R600 optocouplers - MOS-FET output, 58 V DC, 2 A, width 6 mm

Rated control supply voltage Connection type Type Order code Pkg qty

Weight(1 pc)kg (lb)

5 - 12 V DC Screw OBOC2000-5-12VDC 1SNA645050R1700

10 0.02 (0.044)

24 V DC Screw OBOC2000-24VDC 1SNA645051R0400

24 V AC/DC Screw OBOC2000-24VUC 1SNA645025R2200

48 - 60 V AC/DC Screw OBOC2000-48-60VUC 1SNA645053R0600

115 V AC/DC Screw OBOC2000-115VUC 1SNA645054R0700

230 V AC/DC Screw OBOC2000-230VUC 1SNA645026R2300

5 - 12 V DC Spring OBROC2000-5-12VDC 1SNA645550R1100

24 V DC Spring OBROC2000-24VDC 1SNA645551R0600

24 V AC/DC Spring OBROC2000-24VUC 1SNA645525R2400

48 - 60 V AC/DC Spring OBROC2000-48-60VUC 1SNA645553R0000

230 V AC/DC Spring OBROC2000-230VUC 1SNA645526R2500

Ordering details R600 optocouplers - MOS-FET output, 58 V DC, 5 A, width 6 mm

Rated control supply voltage Connection type Type Order code Pkg qty

Weight(1 pc)kg (lb)

24 V DC Screw OBOC5000-24VDC 1SNA645024R2100

10 0.02 (0.044)

115 V AC/DC Screw OBOC5000-115VUC 1SNA645058R1300

24 V DC Spring OBROC5000-24VDC 1SNA645524R2300

230 V AC/DC Spring OBROC5000-230VUC 1SNA645559R1600

Page 4: Boxed interface relays and optocouplers R600 Boxed slim ......Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and

4 - Boxed interface relays and optocouplers R600 | Data sheet

Ordering details R600 optocouplers - Triac output, 400 V AC, 1 A, width 6 mm

Rated control supply voltage Connection type Type Order code Pkg qty

Weight(1 pc)kg (lb)

24 V DC Screw OBOA1000-24VDC 1SNA645027R2400

10 0.03 (0.066)

115 V AC/DC Screw OBOA1000-115VUC 1SNA645062R0700

230 V AC/DC Screw OBOA1000-230VUC 1SNA645028R0500

24 V DC Spring OBROA1000-24VDC 1SNA645527R2600

Ordering details R600 optocouplers - Triac output, 230 V AC, 2 A, width 12 mm

Rated control supply voltage Connection type Type Order code Pkg qty

Weight(1 pc)kg (lb)

24 V DC Screw OBOA2000-24VDC 1SNA645029R06005 0.03

(0.066)24 V DC Spring OBROA2000-24VDC 1SNA645529R0000

Ordering details - Accessories Description Type Order code Pkg

qtyWeight(1 pc)kg (lb)

Jumper bar, 10 poles * (replacement of BJ612-10 - 1SNA290488R0100) RB-JB10 1SVR406570R0000

10

0.05 (0.11)

Jumper bar, 20 poles * (replacement of BJ612-20 - 1SNA206754R0000) * RB-JB20 1SVR406580R0000 0.10

(0.22)

Separator end section SC612 1SNA290474R0200 0.05 (0.11)

Front marking blank cards, 100 pcs. RC610 1SNA233000R0100

Terminal marking blank cards, 100 pcs. RC65 1SNA232000R0000

* - Before the first and after the last jumpered R600 relay or optocoupler, a separator end section shall be used. - The sum of the current for jumpered devices shall not exceed 6 A on 6 mm devices and 8 A on 12 mm devices.

Page 5: Boxed interface relays and optocouplers R600 Boxed slim ......Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and

Data sheet | Boxed interface relays and optocouplers R600 - 5

Electrical connection

11-12 n/c contact A1-A2 Control supply voltage 13-14 n/o contact S1 Connection for jumper bar (input side) 11-12/14 1st c/o contact S2 Connection for jumper bar (output side) 21-22/24 2nd c/o contact

A1

A2S1

11S2

12

2CD

C 2

92 0

30 F

0013

A1

A2S1

14S2

13

2CD

C 2

92 0

31 F

0013

A1

A2S1

14S2

13

2CD

C 2

92 0

33 F

0013

RB(R)101R - 24VUC RB(R)111-24VUC RB111-115VUC/230VUC

A1

A2S1

14S2

13

2CD

C 2

92 0

35 F

0013

A1

A2

S111S2

12 14

2CD

C 2

92 0

36 F

0013

A1

A2

S111S2

12 14

2CD

C 2

92 0

38 F

0013

RB(R)111R-24VUC RB(R)121P(G)-5VDC/12VDC RB(R)121-12VDC/24VDC

A1

A2S1

11S2

12 14

2CD

C 2

92 0

39 F

0013

A1

A2S1

11S2

12 142C

DC

292

040

F00

13

A1

A2S1

11S2

12 14

2CD

C 2

92 0

42 F

0013

RB(R)121(G)-24VUC RB(R)121(G)-48-60VUC/ 115VUC/230VUC/60-230VUC

RB(R)121R-115VUC/230VUC

A1

A2S1

11 21

12 14 22 24

2CD

C 2

92 0

43 F

0013

A1

A2S1

11 21

12 14 22 24

2CD

C 2

92 0

44 F

0013

RB(R)122G-24VUC/48-60VUC RB(R)122G-115VUC/230VUC

A1

A2S1

14 (-)S2

13 (+)

2CD

C 2

92 0

19 F

0016

A1

A2S1

14 (-)S2

13 (+)

2CD

C 2

92 0

17 F

0016

A1

A2S1

14 (-)S2

13 (+)

2CD

C 2

92 0

18 F

0016

OB(R)OC, OB(R)IC except 5-12VDC versions

OB(R)IC0100-5-12VDC OB(R)OC2000-5-12VDC

OB(R)OA

Page 6: Boxed interface relays and optocouplers R600 Boxed slim ......Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and

6 - Boxed interface relays and optocouplers R600 | Data sheet

Technical data - Interface relays

RB(R)101R- RB(R)111R-

24VUC 24VUC

Input circuit

Rated control supply voltage Us 24 V AC/DCRated control supply voltage Us tolerance

DC -15 %, +20 %AC -/+ 10 %

Rated frequency 50/60 HzTypical power consumption 0.24 WTypical current 10 mADrop-out voltage at 20 °C 4.5 VIndication of operational states green LED V: control supply voltage applied

Output circuitKind of output 11-12 relay, 1 n/c contact -

13-14 - relay, 1 n/o contactRated operational voltage Ue 250 V ACMinimum switching voltage 12 VMaximum switching voltage 250 V ACMinimum switching current 10 mARated free air thermal current Ith 6 A

Rated operational current Ie

AC-12 (resistive) 230 V 6 AAC-15 (inductive) 230 V 1.5 AAC-15 (inductive) 120 V 3 A

DC-12 (resistive) 24 V 6 ADC-13 (inductive) 24 V 1 A

DC-13 (inductive) 110 V 0.2 ADC-13 (inductive) 220 V 0.1 A

AC rating (UL 508; NEMA ICS-5)

Utilization category (pilot duty)

B300

DC rating (UL 508; NEMA ICS-5)

Utilization category (pilot duty)

R300

Minimum switching power 0.6 W / 0.6 VAMechanical lifetime 1 x 107 switching cyclesElectrical lifetime at AC-15 1 x 105 switching cyclesMax. fuse rating to achieve short-circuit protection 6 A fastResponse time 5 msRelease time 8 ms

RB(R)111-

24VUC 115VUC 230VUC

Input circuit

Rated control supply voltage Us 24 V AC/DC 115 V AC/DC 230 V AC/DCRated control supply voltage Us tolerance

DC -15 %, +20 % -15 %, +10 %AC -/+ 10 %

Rated frequency 50/60 HzTypical power consumption 0.24 W 0.46 W 0.8 WTypical current 10 mA 4 mA 3.5 mADrop-out voltage at 20 °C 4.5 V 17 V 27 VIndication of operational states green LED V: control supply voltage applied

Output circuitKind of output 13-14 relay, 1 n/o contactRated operational voltage Ue 250 V ACMinimum switching voltage 12 VMaximum switching voltage 250 V ACMinimum switching current 10 mARated free air thermal current Ith 6 A

Rated operational current Ie

AC-12 (resistive) 230 V 6 AAC-15 (inductive) 230 V 1.5 AAC-15 (inductive) 120 V 3 A

DC-12 (resistive) 24 V 6 ADC-13 (inductive) 24 V 1 A

DC-13 (inductive) 110 V 0.2 ADC-13 (inductive) 220 V 0.1 A

AC rating (UL 508; NEMA ICS-5)

Utilization category (pilot duty)

B300

DC rating (UL 508; NEMA ICS-5)

Utilization category (pilot duty)

R300

Minimum switching power 0.6 W / 0.6 VAMechanical lifetime 1 x 107 switching cyclesElectrical lifetime at AC-15 1 x 105 switching cyclesMax. fuse rating to achieve short-circuit protection 6 A fastResponse time 5 ms 6 ms 7 msRelease time 8 ms 15 ms 15 ms

Page 7: Boxed interface relays and optocouplers R600 Boxed slim ......Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and

Data sheet | Boxed interface relays and optocouplers R600 - 7

RB(R)121(P)(G)-

5VDC 12VDC 24VDC 24VUC 48-60VUC 115VUC 230VUC

Input circuit

Rated control supply voltage Us 5 V DC 12 V DC 24 V DC 24 V AC/DC 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DCRated control supply voltage Us tolerance

DC -15 %, +20 % -15 %, +10 %AC - -/+ 10 %

Rated frequency - 50/60 HzTypical power consumption 0.2 W 0.2 W 0.24 W 0.33 W 0.54 W 0.46 W 0.8 WTypical current 40 mA 16 mA 10 mA 7 mA 9 mA 4 mA 3.5 mADrop-out voltage at 20 °C 1.2 V 2.2 V 4.5 V 8 V 8 V 17 V 27 VIndication of operational states green LED V: control supply voltage applied

Output circuitKind of output 11-12/14 relay, 1 c/o (SPDT) contactRated operational voltage Ue 250 V ACMinimum switching voltage 12 V / gold-plated contacts: 5 VMaximum switching voltage 250 V ACMinimum switching current 10 mA / gold-plated contacts: 3 mA at 20 VRated free air thermal current Ith 6 A

Rated operational current Ie

AC-12 (resistive) 230 V 6 AAC-15 (inductive) 230 V 1.5 AAC-15 (inductive) 120 V 3 A

DC-12 (resistive) 24 V 6 ADC-13 (inductive) 24 V 1 A

DC-13 (inductive) 110 V 0.2 ADC-13 (inductive) 220 V 0.1 A

AC rating (UL 508; NEMA ICS-5)

Utilization category (pilot duty)

B300

DC rating (UL 508; NEMA ICS-5)

Utilization category (pilot duty)

R300

Minimum switching power 0.6 W / 0.6 VA; gold plated contacts: 0.06 V / 0.06 VAMechanical lifetime 1 x 107 switching cyclesElectrical lifetime at AC-15 1 x 105 switching cyclesMax. fuse rating to achieve short-circuit protection 6 A fastResponse time 5 ms 5 ms 5 ms 5 ms 5 ms 6 ms 7 msRelease time 8 ms 8 ms 8 ms 8 ms 8 ms 15 ms 16 ms

RB(R)121R-

115VUC 230VUC

Input circuit

Rated control supply voltage Us 115 V AC/DC 230 V AC/DCRated control supply voltage Us tolerance

DC -20%, +15% -10%, +15%AC -/+ 10 %

Rated frequency 50/60 HzTypical power consumption 2 W 2.8 WTypical current 18 mA 12 mADrop-out voltage at 20 °C 17 V 27 VIndication of operational states green LED V: control supply voltage applied

Output circuitKind of output 11-12/14 relay, 1 c/o (SPDT) contactRated operational voltage Ue 250 V ACMinimum switching voltage 12 VMaximum switching voltage 250 V ACMinimum switching current 10 mARated free air thermal current Ith 6 A

Rated operational current Ie

AC-12 (resistive) 230 V 6 AAC-15 (inductive) 230 V 1.5 AAC-15 (inductive) 120 V 3 A

DC-12 (resistive) 24 V 6 ADC-13 (inductive) 24 V 1 A

DC-13 (inductive) 110 V 0.2 ADC-13 (inductive) 220 V 0.1 A

AC rating (UL 508; NEMA ICS-5)

Utilization category (pilot duty)

B300

DC rating (UL 508; NEMA ICS-5)

Utilization category (pilot duty)

R300

Minimum switching power 0.6 W / 0.6 VAMechanical lifetime 1 x 107 switching cyclesElectrical lifetime at AC-15 1 x 105 switching cyclesMax. fuse rating to achieve short-circuit protection 6 A fastResponse time 6 ms 7 msRelease time 15 ms 16 ms

Page 8: Boxed interface relays and optocouplers R600 Boxed slim ......Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and

8 - Boxed interface relays and optocouplers R600 | Data sheet

RB(R)122G

24VUC 48-60VUC 115VUC 230VUC

Input circuit

Rated control supply voltage Us 24 V AC/DC 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DCRated control supply voltage Us tolerance

DC -15 %, +20 % -15 %, +10 %AC -/+ 10 %

Rated frequency 50/60 HzTypical power consumption 0.48 W 0.62 W 0.96 W 0.58 W 1.15 WTypical current 20 mA 13 mA 16 mA 5 mA 5 mADrop-out at 20 °C 5.4 V 8.8 V 8.8 V V 20 V 10 VIndication of operational states green LED V: control supply voltage applied

Output circuitKind of output 11-12/14 relay, 1st c/o (SPDT) contact

21-22/24 relay, 2nd c/o (SPDT) contactRated operational voltage Ue 250 V ACMinimum switching voltage 5 VMaximum switching voltage 250 V DC - 250 V ACMinimum switching current 1 mARated free air thermal current Ith 8 A

Rated operational current Ie

AC-12 (resistive) 230 V 8 AAC-15 (inductive) 230 V 1.5 ADC-12 (resistive) 24 V 8 A

DC-13 (inductive) 24 V 1 ADC-13 (inductive) 110 V 0.2 ADC-13 (inductive) 220 V 0.1 A

Minimum switching power 5 mW / 5 mVAMechanical lifetime 2 x 107 switching cyclesElectrical lifetime at AC-15 1 x 105 switching cyclesMax. fuse rating to achieve short-circuit protection 10 A fastResponse time 6 ms 10 ms 10 ms 6 ms 6 msRelease time 10 ms 14 ms 14 ms 15 ms 15 ms

General technical data - Interface relays

RB RBR

General data

Material of housing UL 94 V0

Mounting DIN RailDegree of protection housing /

terminalsIP20 NEMA1

Electrical connection Screw terminal Spring-type terminal

Connecting capacity fine-strand 0.22-2.5 mm² (24-14 AWG)rigid 0.2-4 mm² (24-12 AWG) 0.2-2.5 mm² (24-14 AWG)

Stripping length 9 mm (0.354 in)Tightening torque 0.4-0.6 Nm (3.5-5.3 lb.in) n/aEnvironmental dataAmbient temperature ranges storage -40...+80 °C (-40...+176 °F)

operation -20...+70 °C (-4...+158 °F)Isolation dataRated insulation voltage Ui 250 VRated impulse withstand voltage Uimp

input / output 4 kVshock coil / output 4 kV

output / output 1 kVOvervoltage category IIIPollution degree 2Standards / DirectivesStandards IEC/EN 60947-5-1EMC Directive 2014/30/EULow Voltage Directive 2014/35/EURoHS Directive 2011/65/EU

Page 9: Boxed interface relays and optocouplers R600 Boxed slim ......Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and

Data sheet | Boxed interface relays and optocouplers R600 - 9

Technical data - Optocouplers

OB(R)IC0100-...

5-12VDC 24VDC 48-60VUC 115-230Input circuitInput voltage 5 V DC 12 V DC 24 V DC 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DCFrequency - 50/60 HzInput current 5 mA 9 mA 4 mA 4 mA 5 mA 7 mA (AC)

16 mA (DC)11.5 mA (AC) 25 mA (DC)

Pull-in voltage 4 V 15 V 25 V 60 V AC / 70 V DC

Typ. switch-on time 10 µs 5 msTyp. switch-off time 500 µs 20 msOperating frequency 1000 Hz 20 HzPermissible leakage current 0.9 mA 1.0 mA 0.9 mA 1.6 mAOutput circuit 11(13+)- 14Kind of output TransistorRated operational voltage 4.5-58 V DCMinimum switching current 1 mAMaximum switching current 100 mALeakage current at max. switching voltage < 50 µARated operational current Ie

DC-12 (resistive) 58 V 0.1 A

Residual voltage typical 1 Vmaximum 1.3 V

Max. fuse rating to achieve short-circuit protection 100 mA fastIsolation dataRated insulation voltage Ui 250 VRated impulse withstand voltage Uimp 2.5 kVOvervoltage category IIPollution degree 2

OB(R)OC2000-...

5-12VDC 24VDC 24VUC 48-60VUC 115VUC 230VUCInput circuitInput voltage 5 V DC 12 V DC 24 V DC 24 V AC/DC 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DCFrequency - 50/60 HzInput current 5 mA 9 mA 5.4 mA 6.3 mA 4 mA 5.1 mA 4.2 mA 4 mAPull-in voltage 4 V 12 V 15 V 27 V 50 V 80 VTyp. switch-on time 15 µs 30 µs 1 ms 5 ms 500 µs 1 msTyp. switch-off time 250 µs 400 µs 7 ms 20 ms 10 ms 15 msOperating frequency 2000 Hz 1000 Hz 60 Hz 20 Hz 50 Hz 35 HzPermissible leakage current 1 mA 0.8 mA 0.9mA 1 mA 0.3 mAOutput circuit 11(13+)- 14Kind of output MOS-FETRated operational voltage 4.5-58 V DCMinimum switching current 1 mAMaximum switching current 2 ALeakage current at max. switching voltage < 50 µARated operational current Ie

DC-12 (resistive) 58 V 2 A

Residual voltage typical 0.1 Vmaximum 0.5 V

Max. fuse rating to achieve short-circuit protection 2 A ultra-fastIsolation dataRated insulation voltage Ui 250 VRated impulse withstand voltage Uimp 2.5 kVOvervoltage category IIPollution degree 2

Page 10: Boxed interface relays and optocouplers R600 Boxed slim ......Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and

10 - Boxed interface relays and optocouplers R600 | Data sheet

OB(R)OC5000-...

24VDC 115VUC 230VUCInput circuitInput voltage 24 V DC 115 V AC/DC 230 V AC/DCFrequency - 50/60 HzInput current 5.4 mA 4.2 mA 4 mAPull-in voltage 12 V 50 V 80 VTyp. switch-on time 30 µs 500 µs 1 msTyp. switch-off time 400 µs 10 ms 15 msOperating frequency 1000 Hz 50 Hz 35 HzPermissible leakage current 0.8 mA 0.3 mA 0.3 mAOutput circuit 11(13+)- 14Kind of output MOS-FETRated operational voltage 4.5-58 V DCMinimum switching current 1 mAMaximum switching current 5 ALeakage current at max. switching voltage < 50 µARated operational current Ie

DC-12 (resistive) 58 V 5 A

Residual voltage typical 0.1 Vmaximum 0.5 V

Max. fuse rating to achieve short-circuit protection 6 A ultra-fastIsolation dataRated insulation voltage Ui 250 VRated impulse withstand voltage Uimp 2.5 kVOvervoltage category IIPollution degree 2

OB(R)OA1000-... OB(R)OA2000-...

24VDC 115VUC 230VUC 24VDCInput circuitInput voltage 24 V DC 115 V AC/DC 230 V AC/DC 24 V DCFrequency - 50/60 Hz -Input current 3.6 mA 4.15 mA 4.6 mA 3.6 mAPull-in voltage 14 V 60 V 135 V 14 VTyp. switch-on time 150 µs 2.2 ms 2.5 ms 150 µsTyp. switch-off time 1 ms 18 ms 25 ms 1 msOperating frequency 500 Hz 25 Hz 20 Hz 500 HzPermissible leakage current 1 mA 1 mAOutput circuit 11(13+)- 14Kind of output Triac TriacRated operational voltage 24-400 V AC 10-230 V ACMinimum switching current 25 mA 25 mAMaximum switching current 1 A 2 ALeakage current at max. switching voltage < 500 µA < 500 µARated operational current Ie

AC-12 (resistive) 400 V 1 A -AC-12 (resistive) 230 V - 2A

Residual voltage typical 1 V 1 Vmaximum 1.6 V 1.6 V

Max. fuse rating to achieve short-circuit protection 4 A ultra-fast 4 A ultra-fastIsolation dataRated insulation voltage Ui 400 V 230 VRated impulse withstand voltage Uimp 4 kV 4 kVOvervoltage category II IIPollution degree 2 2

Page 11: Boxed interface relays and optocouplers R600 Boxed slim ......Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and

Data sheet | Boxed interface relays and optocouplers R600 - 11

General technical data - Optocouplers

OB OBR

General dataMaterial of housing UL 94 V0

Mounting DIN Rail

Degree of protection housing / terminals IP20 NEMA1

Electrical connection Screw terminal Spring-type terminal

Connecting capacity fine-strand with/without wire end ferrule 0.22-2.5 mm² (24-14 AWG)rigid 0.2-4 mm² (24-12 AWG) 0.2-2.5 mm² (24-14 AWG)

Stripping length 9 mm (0.354 in)Tightening torque 0.4-0.6 Nm (3.5-5.3 lb.in) n/aEnvironmental dataAmbient temperature ranges storage -40...+80 °C (-40...+176 °F)

operation -20...+70 °C (-4...+158 °F)Standards / DirectivesStandards IEC/EN 60947-5-1EMC Directive 2014/30/EULow Voltage Directive 2014/35/EURoHS Directive 2011/65/EU

Page 12: Boxed interface relays and optocouplers R600 Boxed slim ......Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and

12 - Boxed interface relays and optocouplers R600 | Data sheet

Technical diagrams

Load limit curves

resistive load

DC current [A]

DC

vo

ltag

e [V

]

20105210.2 0.50.110

20

30

4050

300

200

100

2CD

C 2

92 0

02 F

0212

DC current [A]

resistive load

20

20

304050

100

200

300

1010

510.50.20.1 2

DC

vo

ltag

e [V

]

2CD

C 2

92 0

28 F

0213

Versions with 1 n/o, 1 n/c or 1 c/o contact Versions with 2 c/o contacts

Dimensions

in mm and inches

70 2.76”

35 1.38”

67.5

2.66

”75

2.95

2CD

C 2

92 0

25 F

0013

75 2.95”

67.5

2.66

75 2.95

37.5 1.48”

2CD

C 2

92 0

26 F

0013

Versions with screw terminals Versions with spring-type terminals

Further documentation

Document title Document type Document number

Electronic relays and controls Catalog 2CDC 110 004 C02xx

You can find the documentation on the internet at www.abb.com/lowvoltage -> Automation, control and protection -> Electronic relays and controls -> Interface relays and optocouplers.

CAD system files

You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com -> Low Voltage Products & Systems -> Control Products -> Electronic Relays and Controls.

Page 13: Boxed interface relays and optocouplers R600 Boxed slim ......Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and

ABB STOTZ-KONTAKT GmbHP. O. Box 10 16 8069006 Heidelberg, GermanyPhone: +49 (0) 6221 7 01-0Fax: +49 (0) 6221 7 01-13 25E-mail: [email protected]

You can find the address of your local sales organization on the ABB home pagehttp://www.abb.com/contacts -> Low Voltage Products and Systems

Contact us

Note:We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.

We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG.

Copyright© 2017 ABB All rights reserved

Do

cum

ent

num

ber

1S

VC

117

001

D02

00 R

ev.

F (0

1.08

.201

7)