BOLNIK IN VENTILATOR
VELIKO RAZLOGOV ZA NEUJEMANJE
Prim.mag. Ognjen CEROVIĆ, dr.med.
UKCL, KOAITOS, CIT
SODOBNI VENTILATORJI NUDIJO• ŠTEVILNE OBLIKE DIHALNE PODPORE
• ŠIROKO PALETU MOŽNOSTI PRILAGAJANJA PACIJENTOVIM POTREBAM
• SOFISTICIRANI NADZOR DIHALNE PODPORE
NE GLEDE NA IZBRANO OBLIKO PODPOREVENTILATOR JE ČRPALKA, KI• DELNO ALI POPOLNOMA
• ZAČASNO ALI ZA STALNO
NADOMEŠČA PACIJENTOVO DIHALNO ČRPALKOVENTILATOR NI INTELIGENTNA MAŠINA
• DELA SAMO TISTO KAR MU JE NARUČENO
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
NADZOR NAD BOLNIKOM IN DELOM VENTILATORJA MED
IZVAJANJEM MEHANSKEGA PREDIHAVANJA, JE NUJEN!!!
OBPOSTELJNI NADZOR MED MEHANSKIM PREDIHAVANJEM TEMELJI NA:
• FIZIKALNEM PREGLEDU BOLNIKA
• SPREMLJANJU NASTAVITEV PREDIHAVANJA
• OPAZOVANJU KRIVULJ PREDIHAVANJA NA MONITORJU
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
ČETVERO-
KOTNA
NARAŠČAJOČA PADAJOČA SINUSNA EKSPONENTNO
NARAŠČAJOČA
EKSPONENTNO
PADAJOČA
OSNOVNE KRIVULJE VNETILATORJA
Mellema MS, 2013
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJET
lak
Pre
tok
Volu
men
Čas
Čas
Čas
Čas
Tla
kP
reto
kV
olu
men
Čas
Čas
Čas
VOLUMSKO KONTROLIRANO PREDIHAVANJE TLAČNO KONTROLIRANO PREDIHAVANJE
Mellema MS, 2013
KRIVULJE KONTROLIRANEGA PREDIHAVANJA
KRIVULJE PODPORNEGA PREDIHAVANJA
A – MANDATORNI VOLUMSKO
KONTROLIRANI VDIH
B – SPONTANI VDIH
C - SINHRONIZIRANI SIMV VOLUMSKO
KONTROLIRANI VDIH
D – SINHRONIZIRANI SIMV/PS VDIH
Mellema MS, 2013
ČAS
ČAS
ČAS
Tla
kP
reto
kV
olu
men
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
DEFINICIJA INTERREAKCIJE BOLNIK – VENTILATOR
INTERREAKCIJA BOLNIK - VENTILATOR JE POSLEDICA VPLIVOV DVEH KONTROLNIH MEHANIZMOV (DVEH ČRPALK), KATERI MORAJU BITI VSKLAJENI, DA BI BOLNIK OD TOGA IMEO KORIST.
Kondili E. Br.J. Anesth. 2003;91:106-19
UJEMANJE MED BOLNIKOM IN VENTILATORJEM
BOLNIKOVRESPIRATORNI SISTEM
VENTILATOR
KLINIK
Neuromuskularnisistem
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
BOLNIKOVAČRPALKA
NEURALNI DIHALNINAPOR
BOLNIKOVRESPIRATORNI SISTEM
BOLNIKOVAČRPALKA VENTILATOR
BOLNIKOVRESPIRATORNI SISTEM
VENTILATOR
NEUJEMANJE BOLNIKAIN VENTILATORJA
VSI DELI DIHALNEGA CIKLUSA SO USKLAJENI
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
NEURALNI DIHALNINAPOR
BOLNIKOVAČRPALKA
NEURALNI DIHALNINAPOR
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
Bosma KJ, 2012
S STRANI BOLNIKA• NIVO SEDACIJE, BOLEČINE,
IMOBILIZACIJA
• INSPIRATORNI NAPOR/DIHALNI NAGON; NEURALNI TIMING
• PATOLOŠKI PROCESI NA PLUČIH ALI V TREBUHU; ↑SEKRECIJA
• PEEPi
• VELIKOST IN TIP ENDOTRAHEALNE CEVI
• IZGUBA DIHALNE MEŠANICE IZ SISTEMA
DEJAVNIKI NEUJEMANJA BOLNIKA IN VENTILATORJA
S STRANI VENTILATORJA
• ZNAČILNOSTI SPROŽILCA: OSNOVNI PRETOK, PODTLAK
• OBČUTLJIVOST SPROŽILCA
• TEHNIČNE ZNAČILNOSTI SISTEMA ZA DOVAJANJE DIHALNE MEŠANICE
• IZABRANA OBLIKA PRETOKA
• DIZAJN EKSPIRATORNE ZAKLOPKE
• DRUGI PRETOKI (NEBULIZATOR, DODATNI O2)
MED MEHANSKIM PREDIHAVANJEM SE BOLNIKOVO STANJE POGOSTO SPREMINJA.PRAV TAKO, SE SPREMINJA UJEMANJE BOLNIKA IN VENTILATORJA
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
!
Mellema MS, 2013Nilsestuen JO. 2005
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
4 FAZE DIHALNEGA
CIKLUSA
VPIHOVANJE(UDIH)
PREKLOP(KONEC VDIHA)
IZDIH
SPROŽITEVVDIHA
PREKLOP(CYCLING)
DIHALNI CIKLUS
4 FAZE DIHALNEGA
CIKLUSA
VPIHOVANJE(UDIH)
PREKLOP(KONEC VDIHA)
IZDIH
OBČUTLJIVOST SPROŽILCA
PACIENTOV NAPOR
OBČUTLJIVOST ZAKLOPK
BOLNIK POTREBUJE USTREZEN PRETOK
VSKLAJEN Z BOLNIKOVONEURALNO FREKVENCO
MOŽNA PRISOTNOST DINAMIČNE
HIPERINFLACIJE/PEEPi
Mellema MS, 2013Nilsestuen JO. 2005
SPROŽITEVVDIHA
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
PREKLOP
Z BOLNIKOVIM SODELOVANJEM
BREZ BOLNIKOVEGA SODELOVANJA
SPROŽITEV VDIHA
• BOLNIK JE GLOBOKO SEDIRAN/RELAKSIRAN• NI SPONTANIH VDIHOV• DIHALNE MIŠICE NISO AKTIVNE• POGOJI PREDIHAVANJA VNAPREJ ODBRANI
Levine S, NEJM, 2008
VZDRŽUJ PREPONO AKTIVNOM!!!
PO 18-69 UR MEHANSKE VENTILACIJE BREZ SODELOVANJA PREPONE PRIDE DO POMEMBNEGA ZMANJŠANJA VELIKOSTI MIŠIČNIH FIBRIL (53 – 57%)
VELIKOST FIBRIL
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
S PRETOKOM– POPREJ NASTAVLJENA HITROST PRETOKA,
POTREBNEGA, DA SE SPROŽI DIHALNI CIKLUS – 1-3 L/min
– POTREBEN JE OSNOVNI PRETOK 10-20 L/min ALI 1,5 L/min NAD SPROŽITVENIM PRETOKOM
BOLNIK
A=B NI VDIHA A>B JE VDIH
A B
S PODTLAKOM – POPREJ NASTAVLJENA VREDNOST PODTLAKA,
POTREBNA ZA ZAČETEK DIHALNEGA CIKLUSA
– PODTLAK NAREDI BOLNIK SAM S POSKUSOM VDIHA
– NI OSNOVNEGA PRETOKA V SISTEMU – IZGUBLJENO DIHALNO DELO
– NASTAVITVE PODTLAKA• OPTIMALNO: 1 cm H2O
• PREVISOKO: => 3 cm H2O• POVEČANO DIHALNO DELO
• > 15 – 20 cm H2O – ZA PREPREČAVANJE BOLNIKOVEGA VDIHA
• PRENIZKO: < 0,5 cm H2O• NEKONTROLIRANO SPROŽANJE DIHALNEGA CIKLUSA
• HIPERVENTILACIJA
Z BOLNIKOVIM SODELOVANJEM
BREZ BOLNIKOVEGA SODELOVANJA
SPROŽITEV VDIHA
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
NEUJEMANJE MED SPROŽITVIJO VDIHA – „TRIGGER ASYNCHRONY“
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
NAJPOGOSTEJŠE OBLIKE
• NEUČINKOVITO SPROŽANJE – NI DOSEŽEN PRAG SPROŽITVE
• DVOJNO SPROŽANJE
• SAMODEJNO SPROŽANJE
POGOSTNOST
• NEUČINKOVITO IN DVOJNO SPROŽANJE > 80% VSEH NEUJEMANJ
• SAMODEJNO SPROŽANJE <2% VSEH NEUJEMANJ
de WIT M. 2011
NEUJEMANJE MED SPROŽITVIJO VDIHA – „TRIGGER ASYNCHRONY“
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
VZROKI• NEUSTREZEN PRAG SPROŽITVE• PEEPi (AIR TRAPPING)• MIŠIČNA SLABOST• ZMANJŠAN DIHALNI NAGON• GLOBOKA SEDACIJA
de WIT M. 2011
NEUČINKOVITO SPROŽANJE
POJAVLJA SE PRI• KOPB BOLNIKIH• PREVELIKH DIHALNIH VOLUMNIH
UKREP• ↓ DIHALNI VOLUMEN• OMOGOČITI LAŽJI IZDIH
VENTILATOR NE ŠTEJE NEUSPELE CIKLUSE !
NEUJEMANJE MED SPROŽITVIJO VDIHA – „TRIGGER ASYNCHRONY“
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
DVOJNO SPROŽANJE
VZROKI:• VZDIHOVANJA• KAŠELJ U ČASU DIHALNEGA
NAPORA• POTREBA PO VELIKI
MINUTNI VENTILACIJI ALI• PRENISKO NASTAVLJENEM
VOLUMNU ALI PRETOKU• KOMBINACIJA NAVEDENIH
THILE AW. 2006de WIT M. 2011
NEUJEMANJE MED SPROŽITVIJO VDIHA – „TRIGGER ASYNCHRONY“
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
SAMODEJNO SPROŽANJE
VZROKI• IZGUBE DIHALNE MEŠANICE IZ
SISTEMA• NIHANJA VODE V CEVEH
DIHALNEGA SISTEMA• PULZACIJE SRCA• NEUSTREZNO NASTAVLJEN
PRAG SPROŽILCA
Mellema MS, 2013de WIT M. 2011
SAMODEJNO SPROŽANJE ZARADI IZGUBE IZ SISTEMA
NEUJEMANJE MED VDIHOM – „FLOW ASYNCHRONY“
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
• KONTRAKCIJA DIHALNIH MIŠIC SE NE KONČA PO SPROŽITVI VDIHA
• NASTANE, KER PRETOK NE USTREZA BOLNIKOVIM POTREBAM
• NEUJEMANJE BOLNIKA IN VENTILATORJA JE MOŽNO PRI
• STALNEM PREROKU (VCV)
• SPREMENLJIVEM PRETOKU (PCV)
• VZROK NEUJEMANJA JE NEPRAVILNA NASTAVITEV HITROSTI PRETOKA
• PREPOČASEN
• PREHITER
de WIT M. 2011
• PRESSURE-TIME PRODUCT
– BOLNIKOV NAPOR POTREBEN ZA DOVAJANJE DIHALNEGA VOLUMNA
• ZNAK USPEŠNE SINHRONIZACIJE PRETOKA– IZGLED ASISTIRANE KRIVULJE SE PRIBLIŽUJE IZGLEDU PASIVNE
KRIVULJE
• NEUJEMANJE POGOSTO NASTANE PRI DELNI DIHALNI PODPORI (V-SIMV/PS)
NEUJEMANJE MED VDIHOM – „FLOW ASYNCHRONY“
STALNI PRETOK
A - VCV 35L/minB - PS 55L/MIN
de WIT M. 2011
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
HITROST S KATERO RASTE TLAK MED DIHALNIM CIKLUSOM DO NASTAVLJENE CILJNE VREDNOSTI, DOLOČAJO
• AGRESIVNOST ALGORITMA, KI REGULIRA IZVAJANJE VDIHA• IMPEDANCA PACIJENTA (KOMPLIANSA IN UPOR V DIHALNIH POTEH)• BOLNIKOV INSPIRATORNI NAPOR
FLOW ACCELERATION PERCENT – FAP (RISE TIME)
• OMOGOČA NASTAVITEV HITROSTI NARAŠČANJA TLAKA V SISTEMU - VEČJI JE %, HITREJE JE DOSEŽEN LIMIT TLAKA
• UPORABLJA SE PRI TLAČNI PODPORI DIHANJU (PCV, PS)• SPREMINJANJEM FAP IŠČEMO VREDNOST, KI BOLNIKU
NAJBOLJ USTREZA
FAP
NEUJEMANJE MED VDIHOM – „FLOW ASYNCHRONY“
SPREMENLJIV PRETOK
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
FAP = 1% FAP = 50% FAP = 100%FAP = 1% FAP = 50% FAP = 100%
• PREVISOKO NASTAVLJENE VREDNOSTI FAP NOSIJO RIZIK − PREVISOKEGA TLAKA− IZGUBE DIHALNE MEŠANICE IZ SISTEMA− REAKCIJA PACIJENTA - NAPINJANJE TREBUŠNIH MIŠIC− PRI BOLNIKIH S KOPB LAHKO
• POSLABŠA DINAMIČNU HIPERINFLACIJU I POVEČA PEEPi• POVEČA ŠTEVILO NEUSPELIH AKTIVACIJ DIHALNEGA CIKLUSA• POVEČA DIHALNO DELO
• PRENISKE VREDNOSTI FAP− BOLNIKOVE POTREBE NISO ZADOVOLJENE
Prednastavljena vrednost
NEUJEMANJE MED VDIHOM – „FLOW ASYNCHRONY“
SPREMENLJIV PRETOK
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
• PREKLOP (CYCLING) POMENI KONEC Z VENTILATORJEM PODPRTEGA VDIHA
• VDIH JE KONČAN, KO JE:– DOSEŽEN NASTAVLJENI VOLUMEN
– DOSEŽEN NASTAVLJENI TLAK
– POTEKEL NASTAVLJENI ČAS
• PRI DELNI PODPORI S TLAKOM (PSV) SE VDIH KONČA:– KO JE SODEŽENA NASTAVLJENA MEJA TLAKA
– KO HITROST PRETOKA PADE NA 25% ZAČETNE HITROSTI (OBIČAJNO)
NEUJEMANJE NA KONCU VDIHA – „CYCLING ASYNCHRONY“
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
PREKLOP
PREKLOP(CYCLING)
NEUJEMANJE NA KONCU VDIHA – „CYCLING ASYNCHRONY“
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
PREZGODNJI PREKLOP – „PREMATURE CYCLING“
• BOLNIKOV INSPIRATORNI NAPOR JE ŠE VEDNO PRISOTEN, ČEPRAV JE ASISTIRANI VDIH KONČAN
• MEHANSKI IT < NEVRALNI IT
• DOVOLJ MOČEN INSPIRATORNI NAPOR LAHKO SPROŽI NASLEDNJI VDIH –DVOJNO SPROŽANJE
• POJAVLJA SE PRI• NEUSTREZNEM VT
• POVEČANEMU INSPIRATORNEMU NAPORU
• PRI DVOJNI SPROŽITVI• IZDIHANI VOLUMEN JE PODVOJEN (6ml/Kg 12ml/Kg)• OBSTAJA NEVARNOST VOLOTRAVME
• ODPRAVLJANJE NEUJEMANJA• PODALJŠANJE MEHANSKEGA IT
• POVEČANJE VTde WIT M. 2011MELLEMA MS, 2013
NEUJEMANJE NA KONCU VDIHA – „CYCLING ASYNCHRONY“
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
ZAMUJEN PREKLOP – „DELAYED CYCLING“
• BOLNIK ZAČNE Z IZDIHOM PRED KONCEM MEHANSKEGA VDIHA
• MEHANSKI IT > NEVRALNI IT
• VZROKI NEUJEMANJA• IZGUBA INSPRATORNEGA NAPORA• FORSIRANI IZDIH PRED KONCEM
MEHANSKEGA VDIHA
• ZAMUJENI PREKLOP JE POVEZAN• NEZADOSTEN ČAS IZDIHA• PREVELIK VT
• AIR TRAPPING• NEUČINKOVITO SPROŽANJE
• ODPRAVLJANJE NEUJEMANJA• SKRAJŠANJE MEHANSKEGA IT
• MANJŠI VTde WIT M. 2011MELLEMA MS, 2013
Preset ESENS
Patient Flow Increased ESENS
EXPIRATORY SENSITIVITY – ESENS (EXPIRATORY TRIGER)• DEFINIRA % OD VREDNOSTI MAKSIMALNEGA INSPIRATORNEGA PROTOKA PRI
KATEREM SE VDIH KONČA• REGULACIJA FAP IN ESENS
• PRVO NASTAVIMO FAP• ESENS NASTAVIMO GLEDE
NA NASTAVLJENI FAP
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
REGULIRANJE PREKLOPA PRI TLAČNI PODPORI DIHANJU
ESENS > 25%• SKRAJŠA ČAS VDIHA IN PODALJŠA IZDIH • LAHKO BITNO ZMANJŠA VELIKOST DIHALNEGA VOLUMNA• ZMANJŠA PEEPi• IZBOLJŠA OBČUTLJIVOST VENTILATORJA →MANJŠE ŠTEVILO NEUSPELIH SPROŽANJ
ESENS < 25% • POSLABŠA UJEMANJE BOLNIKA IN VENTILATORJA
20% (Set)
40% (Set)35% (Actual)
A. PODALJŠAN VDIH ZARADI SLABEGA TESNENJA SISTEMA I NISKO NASTAVLJENEGA ESENS
B. VIŠJE NASTAVLJEN ESENS PRIVEDE DO ZGODNEJŠEGA KONCA VDIHA
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
REGULIRANJE PREKLOPA PRI TLAČNI PODPORI DIHANJU
NEUJEMANJE MED IZDIHOM – „EXPIRATORY ASYNCHRONY“
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
• IZDIH JE PRAVILOMA PASIVEN
• NEUJEMANJE JE POSLEDICA INTRINZIČNEGA PEEP-a / DINAMIČNA HIPERINFLACIJA• VISOKA FD, KRATEK ČAS IZDIHA, BOLEZNI PLJUČ
• NEGATIVEN VPLIV DINAMIČNE HIPERINFLACIJE NA ZAČETEK VDIHA• OTEŽENO DOSEGANJE PRAGA SPROŽITVE
• UKREP: ↑ PEEP
• ODPRAVLJANJE NEUJEMANJA• GLAVNI CILJ PODALJŠANJE ČASA IZDIHA
• OBČUTLJIVOST SPROŽILCA• PRILAGODITEH HITROSTI IN OBLIKE PRETOKA• FAP, MEHANSKI IT, I:E RAZMERJE• FD
IZDIH
NEUSPEH AKTIVACIJE DIHALNEGA CIKLUSA JE MOGOČ PRI BILO KATERI ASISTIRANI OBLIKI DIHALNE PODPORE
POPOLNA VSKLAJENOST NEVRALNEGA IN MEHANSKEGA KONCA VDIHA JE REDKA
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
• BOLNIK SE „BORI“ Z VENTILATORJEM
• POTREBNA JE GLOBJA SEDACIJA → DALJŠI ČAS MP
• VEČJE DIHALNO DELO
• OKVARA MIŠIC
• MOTNJE VENTILACIJE/PERFUZIJE
• DINAMIČNA HIPERINFLACIJA
• ZAPOZNELI ALI PODALJŠNI PREHOD NA SPONTANO DIHANJE
• DALJŠI ČAS BIVANJA V ENOTI IT
• VIŠJI STROŠKI ZDRAVLJENJA
€ € € € €…
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
POSLEDICE NEUJEMANJA BOLNIKA IN VENTILATORJA
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE
18 DNINEUJEMANJE BOLNIKA IN VENTILATORJA PRISPEVA 18 DODATNIH DNI MEHANSKEGA PREDIHAVANJA
24%VSEH MEHANSKO PREDIHAVANIH BOLNIKOV DOŽIVI NEUJEMANJE Z VENTILATORJEM PRI VSAKEM 10-em VDIHU
72000$POVPREČNI STROŠKI MEHANSKEGA PREDIHAVANJA NA DAN SO ~ 4000$
NEKAJ ŠTEVILK
THILLE a. 2006
DASTA J. 2005
SKLEPI• NUJEMANJE BOLNIKA IN VENTILATORJA JE MOŽNO V VSEH ŠTIRIH DELIH
DIHALNEGA CIKLUSA
• KRIVULJE VENTILATORJA JE TREBA REDNO NADZOROVATI (NA URO)
• UKREPANJE OB UGOTOVITVI, DA SE BOLNIK „BORI“ Z VENTILATORJEM NAJ BO HITRO
• FIZIKALNI PREGLED IN ANALIZA KRIVULJ STA KLJUČNI ZA UGOTAVLJANJE VZROKA NEUJEMANJA
• NEUJEMANJE BOLNIKA IN VENTILATORJA LAHKO IMA ŠTEVILNE RESNE POSLEDICE ZA BOLNIKA IN NJEGOVO ZDRAVLJENJE
• ZA DOSEGANJE UJEMANJA BOLNIKA IN VENTILATORJA JE POTREBNO OBILO ZNANJA IN IZKUŠENJ LEČEČEGA ZDRAVNIKA
BOLNIK IN VENTILATOR - VELIKO RAZLOGOV ZA NEUJEMANJE