4
Fully Waterproof Can Improve U-VALUE To 0.20 W/m 2 K! (See back page) FIRE RETARDANT CFC/HCFC Free Independently Tested for Breathability Out-performs Traditional Breather Membrane Meets 2010 Building Regulations NHBC Acceptance FR PLASTERBOARD VAPOUR CONTROL LAYER SHEATHING BOARD GLASS FIBRE INSULATION 75mm BREATHABLE OPEN LAP TO ALLOW MOISTURE TO ESCAPE OUTER BRICKWORK 100mm BLOCK WORK CAVITY Breather-Foil FR (FLAME RETARDANT BREATHER) MEMBRANE FOIL FACING OUTWARDS STAPLED TO PLYWOOD SOLE PLATE CHIPBOARD FLOORING STOPS 10MM SHORT OF STUD FLOOR JOIST VENTED AIR SPACE DPC FOIL-TEC DOUBLE WALL TIE STUD WORK ADVANCES www.ybsinsulation.com FOR TIMBER FRAME/ MODULAR HOUSING APPLICATIONS NOW AVAILABLE 2.62m wide rolls! Speed up your production! YOUR COMPANY LOGO AND COLOURED MEMBRANE HERE! Call: 0844 99 100 44 For Details Cert. No. 08/0315 Breather- Foıl INSULATING FIRE RETARDANT Breather Membrane BDA Agrément No. BAKQW 10-01

BDA Agrément No. BAKQW 10-01 Breather-Foıl FRinstallation benefits: Breather-Foil FR - timber frame build up Breather-Foil FR protects the timber frame ... Breather-Foil FR is a

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: BDA Agrément No. BAKQW 10-01 Breather-Foıl FRinstallation benefits: Breather-Foil FR - timber frame build up Breather-Foil FR protects the timber frame ... Breather-Foil FR is a

Fully Waterproof

Can Improve U-VALUE To 0.20 W/m2K! (See back page)

FIRE RETARDANT

CFC/HCFC Free

Independently Tested for Breathability

Out-performs TraditionalBreather Membrane

Meets 2010 Building Regulations

NHBC Acceptance

FR

PLASTERBOARD

VAPOUR CONTROLLAYER

SHEATHING BOARD

GLASS FIBRE INSULATION

75mm BREATHABLE OPENLAP TO ALLOWMOISTURE TO ESCAPE

OUTER BRICKWORK

100mm BLOCK WORK

CAVITY

Breather-Foil FR(FLAME RETARDANTBREATHER) MEMBRANE

FOIL FACING OUTWARDSSTAPLED TO PLYWOOD

SOLE PLATE

CHIPBOARD FLOORINGSTOPS 10MM SHORT OF STUD

FLOOR JOIST

VENTED AIR SPACEDPC

FOIL-TEC DOUBLE

WALL TIE

STUD

WORK ADVANCES

www.ybsinsulation.com

FOR TIMBER FRAME/ MODULARHOUSING APPLICATIONS

NOW AVAILABLE

2.62m wide rolls!

Speed up yourproduction!

YOUR COMPANY LOGO ANDCOLOURED MEMBRANE

HERE!Call: 0844 99 100 44

For Details

Cert. No. 08/0315Breather-FoılINSULATING FIRE RETARDANT Breather Membrane

BDA Agrément No. BAKQW 10-01

Page 2: BDA Agrément No. BAKQW 10-01 Breather-Foıl FRinstallation benefits: Breather-Foil FR - timber frame build up Breather-Foil FR protects the timber frame ... Breather-Foil FR is a

Specially developed for use in timber-frame andmodular building construction, Breather-Foil FR cangreatly increase the U-value of the timber-frame wall.Whether pre-fabricated or assembled on site,Breather-Foil FR can afford the designer andcontractor maximum flexibility when detailing timber-frame walls, without the expense of thickertimber frames or higher priced materials.

The Breather-Foil FR timber-framed wall systemcreates a wind-tight, draught-free, weather-sealed, yet vapour-permeable enclosure, when used inconjunction with external cladding, such as tile-hanging, masonry or weather-boarding.

Breather-Foil FR is available with or without a removable coloured membrane (which can carry your company logo!).

The Breather-Foil FRtimber-frame wall systemalso offers the followinginstallation benefits:

Breather-Foil FR - timber frame build up Breather-Foil FR protects the timber frame

• Breather-Foil FR protects the timber frame components during construction

• Breather-Foil FR details and installation procedures apply regardless of cladding type

• Breather-Foil FR will protect the timber and insulation components from the elements

Vapour flow detail atthe reverse ofBreather-Foil FR

PLASTERBOARD

VAPOUR CONTROLLAYER

SHEATHING BOARD

GLASS FIBRE INSULATION

75mm BREATHABLE OPENLAP TO ALLOWMOISTURE TO ESCAPE

OUTER BRICKWORK

100mm BLOCK WORK

CAVITY

Breather-Foil FR(FLAME RETARDANTBREATHER) MEMBRANEFOIL FACING OUTWARDSSTAPLED TO PLYWOOD

SOLE PLATE

CHIPBOARD FLOORINGSTOPS 10MM SHORT OF STUD

FLOOR JOIST

VENTED AIR SPACE

CONCRETE OVERSITE

CONCRETE INFILL

Breather-Foil FR

repels water entering

across the cavity.

Runs over horizontal

laps.

Vapour

Control Layer

prevents

water vapour

entering

the wall.

BUT any water vapourthat does enter the wallcan exit through theunique open bubblestructure and out of theopen laps.

(Tested to BS EN 12153:2000 for

water-tightness and air permeability)

DPC

FOIL-TEC DOUBLE

WALL TIE

STUD

COMPREHENSIVE FIXING DETAILS ARE AVAILABLE UPON REQUEST

Breather-FoılINSULATING FIRE RETARDANT Breather Membrane

FR

FOR TIMBER FRAME/MODULAR HOUSING

APPLICATIONS

Page 3: BDA Agrément No. BAKQW 10-01 Breather-Foıl FRinstallation benefits: Breather-Foil FR - timber frame build up Breather-Foil FR protects the timber frame ... Breather-Foil FR is a

FACTORY ASSEMBLYThe timber framework is to be constructed with the sheathing board inposition. Breather-Foil FR is rolled out into position and then stapled tothe sheathing board. An overlap of 200mm must be allowed at the loweredge of the panel. This is to allow for coverage of the lower sole plate orupper floor joists. An overlap of 150mm must be allowed at the right handedge of the panel. This is to allow for coverage and sealing of the verticaljoint on assembled panels. The end overlap and the bottom overlapshould not be stapled, but left loose for site fixing.

All mid panel horizontal joints have an overlap of 75mm. The upper layermust overlap the lower layer to allow any penetrating water to be dispersedto a safe outlet. These horizontal laps are to be left open to allow the panelsto breathe. The location of the timber studs should now be highlighted withindelible ink to allow for future accurate positioning of the wall ties.

Breather-Foil FR INSTALLATION DETAILS

PLEASE REMOVE COLOURED MEMBRANE AS BRICKWORK ADVANCES

PLEASE REMOVE COLOURED MEMBRANE AS BRICKWORK ADVANCES

REMOVE COLOURED MEMBRANE AS BRICKWORK ADVANCES

PLEASE REMOVE COLOURED MEMB NE AS BRICKWORK ADVANCES

PLEASE REMOVE COLOURED MEMB NE AS BRICKWO

AS BRICKWORK ADVANCES PLE

CLADDINGS FOR TIMBER-FRAMED WALL SYSTEMS

Breather-Foil FR can be used inconjunction with most external claddings,such as tile-hanging, masonry or weather-boarding, as shown below.

PROFILE BOARDING

TILE HANGING

COUNTERBATTEN

INSULATION

BATTEN

CLADDING

COUNTERBATTEN

TILES

TILEBATTEN

Breather-Foil FR

INSULATION

Breather-Foil FR

Timber studs are indicated onfoil surface with marker pen.

EDGE - 150mm overlapMUST NOT BE STAPLED

Protective filmis removed asbrickworkprogresses

150mm Foil Overlapstapled on to next panel

Openings are cut andstapled back - or canbe cut flush to edges.

Breather-Foil FR cut flush to edge

Panels slide in to position

1.35m Rolls

BOTTOM - 200mm overlap MUST NOT BE STAPLED

Floor Joists

NOTE: Breather-Foil FR is a highly reflective material. To avoid on-site glare, YBSapply a tinted* membrane which must be removed before the brickwork progresses.

75mm Open Breather Lap

75mm Open Breather Lap

Staples

Any window and door openings are to be cut outwith the Breather-Foil FR and can now be turnedinside the opening and fixed to the studwork orcut flush to the edges of the opening.

STACKING/TRANSPORT Stack and strap the panels, for transport, asnormal. The bubbles compress slightly underload but DO NOT burst. They will reform once thepanel is erected. The smooth surface of BF-FRmeans the timber panels slide off each otherresulting in less damage.

SITE WORKPanels are erected in to position with the over -laps to the bottom and to the right (looking fromoutside). After fixing the panels, the verticaloverlaps are stapled.YBS Breather-Foil FR wall ties are fixedalong the ’marked’ vertical stud line as theexternal brick wall is built. The anti-glaremembrane should be peeled off over the ties asthe brick work progresses.

SITE WORK EXTERIORIf left exposed use edge battens fixed all aroundthe perimeter to help prevent wind lifting anddamaging the Breather-Foil FR in extremeconditions.

75mmOpenBreatherLap

Air Vent

Sole Plate

YOUR LOGO HERE*

Timber Frame Ties

Marker pen linesshowing stud locations

Floor JointingWhere the floor joists are greater than 150mm, aBreather-Foil FR jointing strip of 270mm or337mm is to be used. When stapling, ensurethat the overlaps are face downwards.

Breather-Foil FR

Breather-Foil FR Jointing Strip

Plywood Filler Piece

Breather-Foil FR

Joist

Timber Frame

Sheathing Board

Sheathing Board

Timber Frame

* Various coloured anti-glare membranes are available - call: 0844 99 100 44

200mm overlap - to cover Floor Joists

NOW AVAILABLE

2.62m wide rolls!

Speed up yourproduction!

Page 4: BDA Agrément No. BAKQW 10-01 Breather-Foıl FRinstallation benefits: Breather-Foil FR - timber frame build up Breather-Foil FR protects the timber frame ... Breather-Foil FR is a

Printed using Environmentally Friendly Paper - 100% chlorine free© Yorkshire Building Services (WHITWELL) Ltd

Yorkshire Building Services (WHITWELL) Ltd.The Crags Industrial Park, Morven Street, Creswell, Derbyshire S80 4AJ

Tel: 0844 99 100 44 Fax: 0844 99 100 [email protected] www.ybsinsulation.com Y

BS

181

V4

12/2

010

Technical Data - Breather-Foil FR U-Values

Thickness Thermal ThermalConductivity Resistance

Outside surface (mm) (W/mK) (m2K/W)resistance - - 0.060

Brick, External 102.50 0.770 0.133bridged by 17.2% Mortar (102.5mm)

BF-FR Cavity 50.00 - 0.649

BF-FR Bubble 4.00 - 0.121

Sheath board 9.00 0.130 0.069

Mineral fibre 140.00 0.040 3.500bridged by 15% Timber (140.0mm)

Vapour control layer - - -

Plasterboard 12.50 0.190 0.066

Inside surface resistance - - 0.120

U-value, Combined Method: 0.25W/m2K

Thickness Thermal ThermalConductivity Resistance

(mm) (W/mK) (m2K/W)- - 0.060

102.50 0.770 0.133bridged by 17.2% Mortar (102.5mm)

50.00 - 0.649

4.00 - 0.121

9.00 0.130 0.069

140.00 0.035 4.000bridged by 15% Timber (140.0mm)

- - -

12.50 0.190 0.066

- - 0.120

U-value, Combined Method: 0.23W/m2K

With Mineral Wool U-Value C to 0.23140mm stud - rock fibre

Thickness Thermal ThermalConductivity Resistance

(mm) (W/mK) (m2K/W)- - 0.060

102.50 0.770 0.133bridged by 17.2% Mortar (102.5mm)

50.00 - 0.649

4.00 - 0.121

9.00 0.130 0.069

140.00 0.032 4.375bridged by 15% Timber (140.0mm)

- - -

12.50 0.190 0.066

- - 0.120

U-value, Combined Method: 0.22W/m2K

U-Value B to 0.22140mm stud - high performance glass fibre

U-Value to 0.25 140mm stud - standard glass fibre

Thickness Thermal ThermalConductivity Resistance

Outside surface (mm) (W/mK) (m2K/W)

resistance - - 0.060

Brick, External 102.50 0.770 0.133bridged by 17.2% Mortar (102.5mm)

BF-FR Cavity 50.00 - 0.649

BF-FR Bubble 4.00 - 0.121

Sheathing board 9.00 0.130 0.069

PIR 80.00 0.023 3.478

Stud Cavity 60.00 - 0.340bridged by 15% Timber (140.0mm)

Vapour control layer - - -

Plasterboard 12.50 0.190 0.066

Inside surface resistance - - 0.120U-value, Combined Method:

0.25W/m2K

Thickness Thermal ThermalConductivity Resistance

(mm) (W/mK) (m2K/W)- - 0.060

102.50 0.770 0.133bridged by 17.2% Mortar (102.5mm)

50.00 - 0.649

4.00 - 0.121

9.00 0.130 0.069

100.00 0.023 4.348

40.00 - 0.340bridged by 15% Timber (140.0mm)

- - -

12.50 0.190 0.066

- - 0.120U-value, Combined Method:

0.22W/m2K

With PIR U-Value of 0.21140mm stud - 100mm PIR

Thickness Thermal ThermalConductivity Resistance

(mm) (W/mK) (m2K/W)- - 0.060

102.50 0.770 0.133bridged by 17.2% Mortar (102.5mm)

50.00 - 0.649

4.00 - 0.121

9.00 0.130 0.069

110.00 0.023 4.783

30.00 - 0.665bridged by 15% Timber (140.0mm)

- - -

12.50 0.190 0.066

- - 0.120U-value, Combined Method:

0.20W/m2K

U-Value of 0.20140mm stud - 110mm PIR+ Foiltec VCL

U-Value of 0.25 140mm stud - 80mm PIR

0

100

0

200

300

400

500

600

700

800

OSB board open joints

Breather-Foil FR

OSB board + breather paper

Airf

low

(m

3/ho

ur)

Test Pressure (Pa)

Measured Values of Airflow

20015010050

Breather-Foil FR - Technical SpecificationThe investigation on thermal performance has been performedaccording to EN 12667: ‘Thermal performance of building materialsand products - Determination of thermal resistance by means ofguarded hot plate and heat flow meter methods - Product of highand medium thermal resistance (2001-02)’. This meets allrequirements of BR443 for use as a thermal insulationBreather-Foil FR Bubble 0.121m2 K/WBreather-Foil FR Cavity 0.649 m2 K/WBreather-Foil FR - Total Thermal Resistance 0.770 m2 K/W Vapour Resistance 0.40 MNs/gInstalled air permeability at 50Pa BS EN 12153: 54m3 / m2 (24hr)Nail Tear Resistance BS4016 (wet & dry) 0 min 70NEnvironmental CFC & HCFC FreeDimensions

Thickness 4mmWidth 1350mm/2620mmLength 50m/25mJointing Strip (to suit truss depth) 270, 337, 450mm x 50mFoil Tape 50m x 75mm (24 rolls/box)

Hygrothermal researchby the BRE and supervised by TRADA - and BDABreather-Foil FRwas subjected to extremeinternal and external conditionsand left for an extended periodof time. Moisture content of thetimber structure was well withinacceptable limits.

Rainscreen/WatertightnessBreather-Foil FR has beensuccessfully tested for watertightness and is an effectiverainscreen. (EN 1254:1999 Class R5).

Please contact YBS Technical on: 0871 917 0044 for moreinformation.

Many U-value combinations are available. All U-values using Combined Method - timber content at15%. Other materials to BRE conventions for U-values or using manufacturers’ certified data. Mineral fibre to new European CE marking.

In airflow tests by the BRE, Breather-Foil FR allowed more air out than a standard breather membrane.

D E F

Construction TypeElement: Wall

Exposure: Normal

Internal surface emissivity: High

External surface emissivity: High

Building use: BS5250 dry/moist occupancy

A B C