31
PRIVATE BRANCH EXCHANGE Meridian 1 – Option 81C CONTENTS BASIC TELEPHONE SYSTEMS. …………………………………………………………………………………………………… MERIDAIN SYSTEM MODELS. ……………………………………………………………………………………………………. M1 SYSTEM ARCHITECTURE ……………………………………………………………………………………………………… MERIDAIN 1 HARDWARE …………………………………………………………………………………………………………… COMMON EQUIPMENT.. NETWORK EQUIPMENT. ……………………………………………………………………………………………………………… PERIPHERAL EQUIPMENT …………………………………………………………………………………………………………… E1 SIGNALING ………………………………………………………………………………………………………………………………. OPTION 81C BLOCK DIAGRAM.. M1 CONFIGURATIONOVERLAYS ………………………………………………………………………………………………… PROBLEM DETERMINATION TOOL.. GENERAL INFORMATION – MULTI-GROUP SYSTEMS. …………………………………………………………… MERIDAIN 1 SYSTEM HEALTH CHECK. ……………………………………………………………………………………… REFERNCE ………………………………………………………………………………………………………………………………………. 1

Basics Configuration of PBX -Nortel Meridain 81c

Embed Size (px)

DESCRIPTION

Little Bit Info of Nortel Meridian 81C configuration

Citation preview

Page 1: Basics Configuration of PBX -Nortel Meridain 81c

PRIVATE BRANCH

EXCHANGEMeridian 1 – Option 81C

CONTENTS

BASIC TELEPHONE SYSTEMS. ……………………………………………………………………………………………………MERIDAIN SYSTEM MODELS. …………………………………………………………………………………………………….M1 SYSTEM ARCHITECTURE ………………………………………………………………………………………………………MERIDAIN 1 HARDWARE ……………………………………………………………………………………………………………COMMON EQUIPMENT..NETWORK EQUIPMENT. ………………………………………………………………………………………………………………PERIPHERAL EQUIPMENT ……………………………………………………………………………………………………………E1 SIGNALING ……………………………………………………………………………………………………………………………….OPTION 81C BLOCK DIAGRAM..M1 CONFIGURATIONOVERLAYS …………………………………………………………………………………………………

1

Page 2: Basics Configuration of PBX -Nortel Meridain 81c

PROBLEM DETERMINATION TOOL..GENERAL INFORMATION – MULTI-GROUP SYSTEMS. ……………………………………………………………MERIDAIN 1 SYSTEM HEALTH CHECK. ………………………………………………………………………………………REFERNCE ……………………………………………………………………………………………………………………………………….

This document is for you if you want to learn a bit more about how Meridian 1 – Option 81C PBX system works. This document will be good for those who need to know about the configuration of Meridian 1. A little bit telecommunication knowledge is required to go through this document.

This document has been made with the full reference of M1R25 document of Nortel Networks. So, thanks for the Nortel Networks.

Types of telephone systems

When telephones are required in a building for a group of users, there are several options from which to choose

There are three main types of systems are:

Centrex Key System Private Branch Exchange

Nortel Networks manufactures systems of all the three types.

The Nortel Networks system that servers Centrex telephones is called the DMS systems The Nortel Networks system that servers Key System telephones is called the Norstar systems The Nortel Networks system that servers Private Branch Exchange are called the Meridian 1 systems

PBXs, trunks, and Central Offices

PBXs provide telephone service to large numbers of users, usually between 30 and 10,000.When you are connected to a PBX and you lift the handset of your telephone, the dial tone you hear is coming from the PBX.

2

Page 3: Basics Configuration of PBX -Nortel Meridain 81c

The PBX receives the digits you dial, interprets them and connects you to the destination you want. Sometimes the destination is an internal telephone, connected to the same PBX. Sometimes it is an external telephone connected to the PBX by a trunk.

Trunks are pairs of wires or optical fiber that connect the PBX to an outside system. One of these systems is called a Central Office. The Central Office (or CO) provides telephone service to businesses and residences in your local area.

Central Offices are sometimes called exchange offices. When your call goes out to one of these offices you have accessed the exchange network, sometimes called the public exchange network.

If you have more than one trunk connected to the same end-system, handling the same kinds of calls, arrange them in trunk groups (also called trunk routes). For example, trunks connected to the Central Office that handle public exchange network calls are called Central Office Trunks (COTs).

Analog and digitalThere are trunks that handle analog signals and those that handle digital signals. There are analog and digital PBXs as well as analog and digital telephones.

Analog signals are transmissions that travel along in a wave format. They might travel through a wire (when a signal is traveling along a trunk) or the air (when you are speaking to someone beside you).

Digital signals are on and off pulses put together in a particular sequence. The pulses and the sequence are deciphered by equipment at the other end that can either read the message and understand it digitally or change it into an analog format to be heard and understood by a person. When a telephone or system is called digital it means it is built to send and receive signals in a digital format.

The Meridian 1 is a digital PBX system

The Meridian 1 can be connected to both analog and digital trunks

System models

There are three distinct families or generations of PBX systems manufactured by Nortel Networks. The most recent generation is called the Meridian 1. The earliest Generation was called the SL-1, followed by the generation called the Meridian SL-1.Each generation has at least three models.

3

Page 4: Basics Configuration of PBX -Nortel Meridain 81c

CONTROL

NETWORK

Each model is designed to handle different quantities of telephones. Generally, you can divide each generation into the categories of small, medium and large systems. In the most recent Meridian 1 generation there is also a system that handles a very small number of telephones.

System Name Size RangeOption 11, Option 11E, 11C, 11C compact Very Small SystemsOption 21, Option 21E Small SystemsOption 51, Option 51COption 61, Option 61C

Medium Systems

Option 71, Option 81, Option 81C Large Systems

PBX BASIC ARCHITUCTURE M1 System Architecture

Network Control Bus Control

Network Control Bus

Network Loop Network

ACCESS Network Loop

sTERMINALS TERMINALS

4

CPU

PeripheralEquipment

SwitchingNetwork

USERINTERFACE

MEMORY MASS STORAGEP

O

W

E

R

Page 5: Basics Configuration of PBX -Nortel Meridain 81c

Control Controlling elements of the system Controls high-level call processing, maintenance and I/O

Network Control Bus Carries messages between the control and network elements

Network (Digital Switch) Connects data (conversations) from Network loop as instructed by main computer Controlled by the main computer

Network Loop Routes information from terminals into the Network (digital switch) Carries messages and conversations between the access and network components TIME DIVISION MULTIPLEXING (TDM): Several conversations share the same wire path, but at different times – time is

divided up into time slots

Access Distribution/Multiplexing Concentration Protocol conversion

Terminals Analog Telephone sets Digital Telephone sets Trunks

MERIDIAN 1 HARDWARE

The hardware components of the system belong to three main groups of equipment.

Common Equipment (CE)

Network Equipment (NE)

Peripheral Equipment (PE)

5

Page 6: Basics Configuration of PBX -Nortel Meridain 81c

COMMON EQUIPMENT (or) CONTROL EQUIPMENT

CALL PROCESSOR (CP)

The components in this area of the machine can be called the computer because they control the operation of the rest of the system.

Central Processing Unit (CPU) Memory Disks Input/output ports

The CPU performs the functions required by the telephones and trunks connected to the system.

The memory has all the instructions stored so the CPU can operate.

The disks have a permanent record of the instructions. If the memory is erased because of a power failure, for example, the instructions stored on the disk are automatically loaded into the memory when the power failure ends.

The input/output ports are called Serial Data Interface (SDI) ports. They allow your system maintainer to connect a terminal to the system for programming purposes. If you are going to move, add and change telephones, you will be using this terminal as well. Other devices, such as printers for traffic studies and call detail records, are also connected to these ports

Inter-Processor bus to communicate with in the Control Equipment

INPUT/OUTPUT DISK UNIT WITH CD- ROM (IODU/C)

Software is delivered to Meridian 1 systems by CD-ROM. IODU/C applies to Options 51C, 61C, 81, and 81C.

CORE NETWORK INTERFACE (CNI)

It provides interface between the inter-processor bus and the network shelves It provides interface between the Call Processor and the Three Port Extender (3PE) cards, each CNI can be connected to

two 3PE cards

NETWORK EQUIPMENT

The telephones and trunks interconnected by the PBX are connected using the Network Equipment components of the system.

6

Page 7: Basics Configuration of PBX -Nortel Meridain 81c

Time slots

The system uses timeslots to connect each party on an active call. If two internal telephone users are speaking, the system uses two timeslots to connect them, one for each telephone. If a telephone user is calling out on a trunk, the system uses two timeslots, one for the telephone and another for the trunk.

Loops and Super loops

These timeslots are present on Network Equipment components called Loops. Each Loop has 32 timeslots, if it is an Enhanced or Standard Loop. Meridian 1 systems use Enhanced Loops. Meridian 1 systems can also use newer versions of Loops called Super loops. Super loops have 128 timeslots. Loops and Super loops are cards that sit in the Network Equipment area of the machine. A Virtual Super loop has been introduced in X11 Release 25 to support i2004 Internet Telephones. Up to 1024 telephones can be configured on a single Virtual Super loop for a system, compared to the traditional 512 telephones. Collectively, 32 loops are called a group. The Option 81C is called a multi-group system because you can equip up to five groups.

Introduced in X11 Release 25, Fiber Network fabric (FNP) allows the expansion of Meridian 1 Option 81 and 81C systems from five Network groups to eight Network groups, a 60% increase in port and trunk capacity. A Dual Ring fiber optic network has replaced the intergroup cards and intergroup module in pre-Release 25 Meridian 1 systems.

A Fiber Network provides 7680 timeslots for 3840 simultaneous conversations. This significantly enhances the number of telephones that you can configure on a system.

Network Controller cards ENET – Enhanced Network card (handles 2 network loops, max. 8 per N/W shelf), XNET –Super loop Network card (handles 1 super loop – equivalent to 4 network loops), max. 4 per network shelf)

Digital Trunk Cards DTI – Digital trunk interface (E1 for Europe, T1 for North America), PRI– Primary rate interface (PRI2 for Europe, PRI for North America)

Conference and Tone and Digit Switch CardsWhen you look at your system you will notice there are also Conference cards and Tone and Digit Switch (TDS) cards sitting near the Loop and Super loop cards. They are also part of the Network Equipment. The Conference card supplies extra timeslots to a conversation when additional people are added in a conference. The TDS card supplies tones like dial tone and busy tone, when told to do so by the computer in the system. On some systems, the Conference and TDS functions are combined on dual-function cards.

Peripheral Signaling provides buffering and signaling interface between CPU and peripheral equipment

Clock Controller Provides a stable clock reference for synchronization with the public network (PSTN); requires when system uses digital trunks

PERIPHERAL EQUIPMENT

Line cards and trunk cards

The telephones and trunks on your system are connected to the system with cards that sit on shelves. There are line cards for telephones and trunk cards for trunks.

7

Page 8: Basics Configuration of PBX -Nortel Meridain 81c

On the newer Meridian 1 systems these shelves for cards are housed in modules.There are unique cards designed for each type of telephone and trunk. More than one telephone or trunk is connected to a card. The version of the card determines how many can be connected. When you add more telephones and trunks to your system, you will need to add more cards when the existing ones are fully utilized.

Density

A term, density, is used to describe, in general, the vintage and capacity of a card. For example, when line cards were introduced in 1975, they had four units on them to connect up to four telephones. These are called single-density cards. Later, line cards were introduced with twice as many units for twice as many telephones and these are called double-density cards. The development of new cards continued, with the introduction of quad-density cards that connect up to 16 telephones, and then octal-density cards. These have 32 units, 16 of which are for digital telephones and the other 16 are for associated data terminals that you can connect to the telephones.

PE cards vs. IPE cardsThere are two versions of cards:

Intelligent Peripheral Equipment (IPE) Peripheral Equipment (PE)

Meridian 1 systems can accommodate IPE cards and PE cards. Only upgraded SL-1 and Meridian SL-1 systems can handle IPE cards. If not upgraded, they can only have PE cards.

Intelligent line cards and trunk cards can have more telephones and trunks connected to them than the older, non-intelligent kinds of cards. This saves room in your system and keeps your system small.

XPEC- Controller card – performs protocol conversion between DS30Y (used in super loop side) and DS30X (comm.b/w xpec & ipe). Intelligent cards are served by Super loops. Non-intelligent cards are served by Loops.Other line cards placed in PE XALC, XDLC, XUT, LSE1 and XEM

Ring Generator - generates the electrical signal, which causes an analog set to ring

Digitone receiver (DTR)

If you use Digitone-type telephones, your system has digitone receiver (DTR) cards. Digitone-type telephones are sometimes called 2500 or DTMF telephones. They are analog telephones that out pulse tones when keys on the keypad are pressed.The CPU of your system requires assistance in interpreting these analog tones. The DTR card was designed to interpret these tones and change each tone into a digital signal, suitable for the CPU.You need DTR cards if your system has any Digitone-type telephones, or Digitone-type trunks which carry these tones into your system from other systems.

STIPULATION

The greater the number of Loops or Super loops equipped on your system, the greater the number of timeslots you have. As you add more telephones and trunks to your system it is important to keep the timeslots in mind.

If you do not provision sufficient timeslots, or manage the system properly, the users on your system might begin to complain of poor service. This usually appears first in the form of dial tone delay problems.

8

Page 9: Basics Configuration of PBX -Nortel Meridain 81c

When users lift their handsets to make calls, it is called taking their telephones off-hook. The system attempts to provide dial tone to the telephone that is off-hook. Timeslots are needed in order to provide dial tone. An under-provisioned system will not have enough timeslots for the demand, especially during busy times of the day. If there are not enough timeslots available for dial tone, a user must wait until another user on the same Loop (or Super loop) hangs up. Since Super loops have far more timeslots than Loops, dial tone delays usually do not occur when you use Super loops on your system.

This demand for timeslots is called traffic. You can predict the expected demand with the help of your system supplier. The occurrence of service problems is sometimes called blockage. There are many things you and your system supplier can do initially, and on an ongoing basis, to eliminate blockage. Refer to the module called Traffic for many suggestions.

DTI TRUNK CARDS – E1 SIGNALING (Connecting PBX to the External world)

CAS CCSChannel Associated Signaling Common Channel SignalingThe signaling associated with a channel Same signaling channel for all the channelsNot many features/services possible Many features/services are possibleIn-band Signaling (same channel carries both voice & data) Out of band Signaling (separate channel for signaling) Eg. DTI Eg.ISDN (PRI)

OPTION 81C BLOCK DIAGRAM

9

Page 10: Basics Configuration of PBX -Nortel Meridain 81c

Inter Processor Bus (IPB) Network Bus

LOOPS 0 - 15

CABLES TO INTER-GROUP MODULE

Inter CPU Cables SCSI bus cables

M1 CONFIGURATION - OVERLAYS

What are Overlays?

•Prompt – Response systems used to configure M1 switch.•Used to Create, Modify & Delete configurations•Are identified by “LD xxx” where “xxx” are numbers.

CLASSIFICATION OF OVERLAYS

10

CallProcessor

IODUC Core to Network[CNI]

CORE MODULE 0

Three Port Extender(3PE)

Peripheral Signaling

(PS)

DUALInter-groupSwitch(fnp)

ENETXNET

SDIXCTPRIDTI

Page 11: Basics Configuration of PBX -Nortel Meridain 81c

•Administration Overlays•Maintenance Overlays•Print Overlays

ADMINISTRATION OVERLAYSConfiguration Record (LD 17, LD 97)

Hardware of the System

Loops

To peripheral equipment (ENET) Conference and Tone loops (XCT) T1/E1 (DTI, PRI)

Super loops to IPE shelf – IPE segmentation

TTY’s, Number of CPUs

Background and Midnight routines

Call Processing Data structure allocation

Digitone Receivers (LD 13)

CDB (CUSTOMER DATA BLOCK) – (LD 15)

Characteristics applying to all customer resources are defined in this data block

ROUTES (LD 16)

Logically groups multiple trunks coming\going to a common destination Each route is assigned an Access code (ACOD) which determine which calls it will handle

Trunks (LD 14)

11

Page 12: Basics Configuration of PBX -Nortel Meridain 81c

Links trunks with routes Has a physical location called a Terminal Number (TN)

- TN consists of loop, shelf, card, unit (lscu)

Digital Sets (LD 11)M39XX sets

Analog Sets (LD 10)500, 2500 sets

Attendant Console (LD 12)2250 sets

MAINTENANCE OVERLAYS

LD 30 – Network and signaling DiagnosticsLD 31 – Telephone and Console DiagnosticsLD 32 – Network and peripheral DiagnosticsLD 34 – TDS and DTR Diagnostics

LD 2 – Traffic

Set time and date Set traffics report schedules, print reports

LD 1 – Audit (template audit)

Audits the PBX and BCS template data structures

LD 44 – Software Audit

Audits data structures: Call registers, queues, etc Checks/Repairs network connections, linkages

12

Page 13: Basics Configuration of PBX -Nortel Meridain 81c

PRINT OVERLAYS

LD 20 – Prints TN related data (sets, trunks, DTRs, Dn blocks)LD 21 – Prints Customer Data BlockLD 22 – Configuration Record Data Block

LD 81 – Print a list or count of sets with selected featuresLD 82 – Prints hunting patterns and DN blocksLD 83 – Prints a list of TNs in DES order

LD 97 – Administrates and Print some portions of Configuration record

PROBLEM DETERMINATION TOOL (PDT)

•PDT can be invoked by typing Cntrl+P Cntrl+D Cntrl+T (^P^D^T)

•The user interacts with PDT by means of PDT Shell

•To switch between PDT and Overlays,– From Overlay (OVL000) prompt type ^P^D^T– From PDT (pdt>) prompt type “sl1input”

•PDT has two special operating modes– Debug mode– Super-user mode

• Default is regular mode

•At any time only one PDT shell can be in super-user mode or debug mode.

•In Super-User mode, PDT invokes VxWorks native shell and operates in its context. All VxWorks shell functionality is available in this mode.

Security

–General User Security Level

•Restricted set of PDT commands

13

Page 14: Basics Configuration of PBX -Nortel Meridain 81c

–Expert Security Level

•Full set of PDT commands

•Debug operation mode of PDT shell

•Superuser operation mode of PDT shell

•Direct Access of operating System subroutines and data–Passwords

• (<Rls 22) – xxxxxxxx (Hidden)

• (>= Rls 22) – xxxxxxxxx (Hidden)

Debugging

•PDT provides tools for debugging SL1 tasks and other tasks too

• Debugging activities are based on “Debugging events” and “Debugging Actions”.

• PDT provides access to– Memory [examination and modification]– CPU registers [examination and modification]– Symbolic task trace printing– Retrieving details of system INI– Capturing of Rdtail file

Maintenance Commands

•rds n Opens a particular record•rdgo n Goes to a particular record of the system•rdtail n Prints the latest records of the switch.•pstat Lists the total number of patches in system•pload file Loads a particular patch into the system•pins Inserts a patch into the system•poos Puts a particular patch into out-of-service•pout Removes a particular patch from the memory•osVersion Lists the current software release of the switch•cd /u/ Used to change directories•ll Long listing of file in that directory•rm Removes that particular file name

14

Page 15: Basics Configuration of PBX -Nortel Meridain 81c

•tree /u Lists all the directories in u partition•mv Used to rename a file •cp Used to copy a file•reboot -1 Cold Start•reboot Warm start•sl1Version Lists the current version & the processor type.

General Information

All the terminals connected (access) to the M1 have their individual Physical Address called as TNs and their respective DNs

TN (Terminal Number) consists of Loop, Shelf, Card, unit (lscu)

Option 81C – Multi-group Systems

What’s a Group?Up to 16 loops (or 4 super loops) can be equipped on a single network shelf.The back plane of a network shelf has 32 traces (or links), each of which carries traffic for a single network loop, 2-network shelves together (32 loops) max out the capacity of the back plane, these two shelves constitute a “Network Group” Or “Group”

Multi-group systems require additional equipment

- For network connections between groups- To interface with the core equipment

Maximum 5 groups, 160 loops, 10,000 ports – IGX Maximum 8 groups, 256 loops, 20,000 ports – FNP

MERIDIAN 1 SYSTEM HEALTH CHECK

CPU REDUNDANCY AND STATUS: >LD 135CCED000. stat cpucp 0 16 PASS – ENBL

TRUE REDUNDANTDISK STATE = REDUNDANTHEALTH = 28VERSION = Oct 3 2003, 19:23:08Side = 0, DRAM SIZE = 256 Mbytes

cp 1 16 PASS -- STDBY

TRUE REDUNDANT

15

Page 16: Basics Configuration of PBX -Nortel Meridain 81c

DISK STATE = REDUNDANTHEALTH = 28VERSION = Oct 3 2003, 19:23:08Side = 1, DRAM SIZE = 256 Mbytes

CNI CARD STATUS:>LD 135. stat cni

cni 0 9 0: remote = group 0 ENBLcni 0 9 1: remote = group 1 ENBLcni 0 10 0: remote = group 2 ENBL

cni 1 9 0: remote = group 0 ENBLcni 1 9 1: remote = group 1 ENBLcni 1 10 0: remote = group 2 ENBL

. stat mem

Side = 0, DRAM SIZE = 256 Mbytes Side = 1, DRAM SIZE = 256 Mbytes

MMDU AND ELNK STAUS:>LD 137. statCMDU 0 ENABLED (ACTIVE)CMDU 1 ENABLED (STANDBY)RDUN ENABLEDELNK ENABLEDSDEV 0 OK (KC VALID). stat elnkELNK ENABLEDEthernet (fei unit number 0):Host: PRI_IPInternet address: 10.10.10.11Broadcast address: 10.255.255.255Ethernet address: 00:01:af:04:6c:e0Netmask: 0xff000000; Subnetmask: 0xff00000023237272 packets received; 23574397 packets sent0 input errors; 0 output errors

16

Page 17: Basics Configuration of PBX -Nortel Meridain 81c

0 collisions

ELAN STATUS:>LD 48. STAT ELANSERVER TASK: ENABLED ELAN #: 16 DES: SCCS APPL_IP_ID: 10 .10 .10 .10 LYR7: ACTIVE EMPTY APPL ACTIVE ELAN #: 17 APPL_IP_ID: 10 .10 .10 .13 LYR7: ACTIVE EMPTY APPL ACTIVE

ELAN HOST CONFIGURATION:>LD 117=> prt host ID Hostname IP Address 1 LOCAL_PPP_IF 137.135.192.4 2 REMOTE_PPP_IF 100.1.1.1 3 PRI_IP1 10.10.10.11 4 SEC_IP1 10.10.10.12 OK=> prt route ID Network Gateway 10.0.0.0 10.10.10.0 OK

=> prt elnkACTIVE ETHERNET: "PRI_IP1" "10.10.10.11"INACTIVE ETHERNET: "SEC_IP1" "10.10.10.12"OK

FIJI RING AND CARD STATUS:

>LD 39. stat ring 0

RING STATE: DRIVES HALF (000 - 479)RING AUTO RECOVERY IS ONFIJI 0 0 ENBLFIJI 1 0 ENBL

17

Page 18: Basics Configuration of PBX -Nortel Meridain 81c

FIJI 2 0 ENBLFIJI 3 0 UNEQ FIJI 4 0 UNEQ FIJI 5 0 UNEQ FIJI 6 0 UNEQ FIJI 7 0 UNEQ

. stat ring 1

RING STATE: DRIVES HALF (480 - 959)RING AUTO RECOVERY IS ONFIJI 0 1 ENBLFIJI 1 1 ENBLFIJI 2 1 ENBLFIJI 3 1 UNEQ FIJI 4 1 UNEQ FIJI 5 1 UNEQ FIJI 6 1 UNEQ FIJI 7 1 UNEQ

SUPERLOOP STATUS:>LD 97SCSYS000MEM AVAIL: (U/P): 22193398 USED U P: 6143328 236966 TOT: 28573692DISK SPACE NEEDED: 329 KBYTES2MB BACKUP DISKETTE(S) NEEDED: 1 (PROJECTED LD43 - BKO)REQ prtTYPE suplSUPLSUPL SUPT SLOT XPEC0 XPEC1 004 STD LEFT 01 0 3 -- - - 008 STD RGHT 06 0 3 -- - - 020 STD LEFT 02 0 1 -- - - 024 STD RGHT 02 2 3 -- - - 036 STD LEFT 03 0 1 -- - - 040 STD RGHT 03 2 3 -- - - 052 STD LEFT 04 0 1 -- - - 056 STD RGHT 07 0 3 -- - - 068 STD LEFT 05 0 1 -- - - 084 STD LEFT 05 2 3 04 2 3

18

Page 19: Basics Configuration of PBX -Nortel Meridain 81c

248 ---- ---- PHANTOM -- - - 252 ---- ---- PHANTOM -- - -

>LD 97REQ prtTYPE xpeXPEC

S0 S1 S2 S3 LOC DIS RGTP

01 004 004 004 004 NO 08 02 020 020 024 024 NO 08 03 036 036 040 040 NO 08 04 052 052 084 084 NO 08 05 068 068 084 084 NO 08 06 008 008 008 008 NO 08 07 056 056 056 056 NO 08

E1 LOOP STATUS:LD 60. stat 18DTI2 LOOP 18 - ENBL REF CLK: DSBLSERVICE RESTORE: YES ALARM STATUS: ACCEPTABLECH 01 - BUSY TIE VOD CH 02 - BUSY TIE VOD CH 03 - IDLE TIE VOD CH 04 - IDLE TIE VOD CH 05 - IDLE TIE VOD CH 06 - BUSY TIE VOD CH 07 - IDLE TIE VOD CH 08 - BUSY TIE VOD CH 09 - IDLE TIE VOD CH 10 - BUSY TIE VOD CH 11 - IDLE TIE VOD CH 12 - BUSY TIE VOD CH 13 - IDLE TIE VOD CH 14 - BUSY TIE VOD CH 15 - BUSY TIE VOD CH 16 - BUSY TIE VOD CH 17 - IDLE TIE VOD CH 18 - BUSY TIE VOD CH 19 - IDLE TIE VOD CH 20 - BUSY TIE VOD CH 21 - IDLE TIE VOD CH 22 - IDLE TIE VOD CH 23 - BUSY TIE VOD CH 24 - BUSY TIE VOD CH 25 - IDLE TIE VOD CH 26 - IDLE TIE VOD CH 27 - IDLE TIE VOD CH 28 - IDLE TIE VOD CH 29 - IDLE TIE VOD CH 30 - IDLE DID VOD

19

Page 20: Basics Configuration of PBX -Nortel Meridain 81c

LSE1 CARD STATUS:>LD 32. stat 68 0 400 = UNIT 00 = IDLE (L500)01 = UNIT 01 = IDLE (L500)02 = UNIT 02 = BUSY (L500)03 = UNIT 03 = BUSY (L500)04 = UNIT 04 = BUSY (L500)05 = UNIT 05 = BUSY (L500)06 = UNIT 06 = BUSY (L500)07 = UNIT 07 = BUSY (L500)08 = UNIT 08 = BUSY (L500)09 = UNIT 09 = BUSY (L500)10 = UNIT 10 = BUSY (L500)11 = UNIT 11 = BUSY (L500)12 = UNIT 12 = BUSY (L500)13 = UNIT 13 = BUSY (L500)14 = UNIT 14 = BUSY (L500)15 = UNIT 15 = BUSY (L500)STATUS OF DLC, FALC AND MFC CARDS:

DLC STATUS:

>LD 32.stat 20 0 400 = UNIT 00 = IDLE (3904 LOG OUT)01 = UNIT 01 = IDLE (3905 LOG OUT)02 = UNIT 02 = IDLE (3905 LOG IN )03 = UNIT 03 = IDLE (3905 LOG OUT)04 = UNIT 04 = IDLE (3905 LOG OUT)05 = UNIT 05 = IDLE (3905 LOG OUT)06 = UNIT 06 = IDLE (3905 LOG OUT)07 = UNIT 07 = IDLE (3905 LOG OUT)08 = UNIT 08 = IDLE (3905 LOG OUT)09 = UNIT 09 = IDLE (3905 LOG OUT)10 = UNIT 10 = IDLE (3905 LOG OUT)11 = UNIT 11 = IDLE (3905 LOG OUT)12 = UNIT 12 = BUSY (3905 LOG IN )

20

Page 21: Basics Configuration of PBX -Nortel Meridain 81c

13 = UNIT 13 = IDLE (3905 LOG OUT)14 = UNIT 14 = IDLE (3905 LOG OUT)15 = UNIT 15 = IDLE (3905 LOG OUT)16 = UNIT 16 = UNEQ17 = UNIT 17 = UNEQ18 = UNIT 18 = UNEQ19 = UNIT 19 = UNEQ20 = UNIT 20 = UNEQ21 = UNIT 21 = UNEQ22 = UNIT 22 = UNEQ23 = UNIT 23 = UNEQ24 = UNIT 24 = UNEQ25 = UNIT 25 = UNEQ26 = UNIT 26 = UNEQ27 = UNIT 27 = UNEQ28 = UNIT 28 = UNEQ29 = UNIT 29 = UNEQ30 = UNIT 30 = UNEQ31 = UNIT 31 = UNEQ

FALC STATUS:

.stat 4 0 000 = UNIT 00 = IDLE (L500)01 = UNIT 01 = IDLE (L500)02 = UNIT 02 = IDLE (L500)03 = UNIT 03 = IDLE (L500)04 = UNIT 04 = IDLE (L500)05 = UNIT 05 = IDLE (L500)06 = UNIT 06 = IDLE (L500)07 = UNIT 07 = IDLE (L500)08 = UNIT 08 = IDLE (L500)09 = UNIT 09 = IDLE (L500)10 = UNIT 10 = IDLE (L500)

21

Page 22: Basics Configuration of PBX -Nortel Meridain 81c

11 = UNIT 11 = IDLE (L500)12 = UNIT 12 = IDLE (L500)13 = UNIT 13 = IDLE (L500)14 = UNIT 14 = IDLE (L500)15 = UNIT 15 = IDLE (L500)

MFC STATUS:

.stat 20 0 000 = UNIT 00 = IDLE MFC01 = UNIT 01 = IDLE MFC02 = UNIT 02 = IDLE MFC03 = UNIT 03 = IDLE MFC

How to list the patches installed in the Meridian?>LD 22REQ: issp

Site ID>LD 22REQ: tid

HOW TO IDENTIFY A SYSTEM PROCESSOR AND GENERIC

'16' => '81C/CP1', '17' => '51C/CP1', '18' => '61C/CP1', '19' => '81C/CP2', '22' => '51C/CP2', '23' => '61C/CP2', '24' => '51C/CP3', '25' => '61C/CP3', '26' => '81C/CP3', '28' => '51C/CP4', '29' => '61C/CP4', '30' => '81C/CP4', '96' => 'INSTALL',

22

Page 23: Basics Configuration of PBX -Nortel Meridain 81c

'97' => 'MDCS ', '98' => 'FoxPSDL', '99' => 'PSDL ', '00' => 'Info ',

1611 = 81/81C CP11711 = 51C CP11811 = 61C CP11911 = 81/81C CP22111 = OPTION 11C (not supported)2211 = 51C CP22311 = 61C CP22411 = 51C CP32511 = 61C CP32611 = 81/81C CP32811 = 51C CP42911 = 61C CP43011 = 81/81C CP4

PROBLEM DETERMINATION TOOL (PDT PROMPT)

PDT: login on /sdi/tty3Password:PDT in Progress. Please Wait....

Done!pdt> hiHealthShow Local (Side 1, Active, Redundant): sio8 1 16 1: 0002 sio8 1 16 2: 0002 sutl 1 15: 0002 strn 1 15: 0002 xsmp 1 15 1: 0002 cnib 1 9: 0002 cnib 1 10: 0002 cnip 1 9 0: 0002 cnip 1 9 1: 0002 cnip 1 10 0: 0002 cnip 1 10 1: 0000 (OutOfService) cmdu 1 16 1: 0008 eth 1 16 0: 0000 (OutOfService) Local Total: 0028

23

Page 24: Basics Configuration of PBX -Nortel Meridain 81c

Remote (Side 0, Inactive, Redundant): sio8 0 16 1: 0002 sio8 0 16 2: 0002 sutl 0 15: 0002 strn 0 15: 0002 xsmp 0 15 1: 0002 cnib 0 9: 0002 cnib 0 10: 0002 cnip 0 9 0: 0002 cnip 0 9 1: 0002 cnip 0 10 0: 0002 cnip 0 10 1: 0000 (OutOfService) cmdu 0 16 1: 0008 eth 0 16 0: 0000 (OutOfService) Remote Total: 0028

value = 0 = 0x0

RDTAILpdt> rdtailRPT: ... rdNotify: SWO happened,default rptFile will open.

RPT: ...rd : 1017 new reports arrived since last command

RPT: ...rd : showing 16 records up to the newest record (rec 86)

71 :(5/6/05 2:00:08.538) SRPT773 TOD 1: Starting midnight job 'rstThr' 72 :(5/6/05 2:00:08.538) SRPT774 TOD 1: Midnight jobs completed 73 :(5/6/05 2:01:57.257) TEMU049 WARNING: record no mismatch, curr= 2, rec= 5 74 :(5/6/05 2:01:58.338) CIOD157 INFO: CMDU 1 is ACTIVE, RDUN is ENABLED 75 :(5/6/05 2:02:00.630) HWI0009 HI FS: saving data to directory "/u/db/hi_b" 76 :(5/6/05 2:03:51.055) TEMU129 BackUP process ended successfully. Number of floppy diskette(s) used: 1 Amount of space remaining on the last floppy: 1055 77 :(5/6/05 2:14:16.369) HWI0655 SUTL: sutlBackGrndTest invoked 78 :(5/6/05 2:14:17.394) SRPT770 TOD 1: Midnight job server started. Number of jobs to do: 2 79 :(5/6/05 2:14:17.394) SRPT773 TOD 1: Starting midnight job 'pchMidNite' 80 :(5/6/05 2:14:32.342) SRPT773 TOD 1: Starting midnight job 'kcm_24h' 81 :(5/6/05 2:14:33.385) SRPT774 TOD 1: Midnight jobs completed 82 :(5/6/05 2:32:52.359) ELAN011 ELAN 17 host IP=10.10.10.13 disabled due tot 83 :(5/6/05 2:32:52.359) ELAN011 ELAN 17 host IP=10.10.10.13 disabled due tot

24

Page 25: Basics Configuration of PBX -Nortel Meridain 81c

84 :(5/6/05 2:42:02.145) ELAN014 ELAN 17 host IP=10.10.10.13 is enabled 85 :(5/6/05 2:42:05.684) SRPT093 AML: local side AML connection 17 to 10.10.. 86 :(5/6/05 2:42:05.684) SRPT091 HB: Local side AML health change:4.value = 0 = 0x0

RDSHOWpdt> rdshow Work file : "/e/rpt/rpt.log"RPT: ... GetTod: record 87 without time_stamp (ROM Report)

File status : full(old reports are replaced by new ones) File capacity : 1372 oldest rec : 87 ( 0/ 0/00 00:00:00) current rec : 86 ( 5/ 6/05 02:42:05) newest rec : 86 ( 5/ 6/05 02:42:05) display size : -16 ( 5/ 6/05 19:21:32)

value = 0 = 0x0

DISK STATUS:

pdt> drShowDisk State is: Master Redundant Normal

Partition 0: Status: active Type: primary Offset: 63 Size: 626472

Partition 1: Status: inactive Type: extended Offset: 626598 Size: 626472

Partition 2: Status: inactive Type: extended Offset: 1253133 Size: 626472

value = 17 = 0x11

25

Page 26: Basics Configuration of PBX -Nortel Meridain 81c

Reference:

M1R25 – Nortel Networks

26