    Electromechanical Multiple andSingle Position Switches

    Electromechanical

    multiple position

    switches

    1.2 Series 100

    per DIN 43697

    1.4 Series 621.6 Series 611.8 Series 72

    1.10 Series 461.12 Series 40

    Electromechanical

    single position

    switches

    1.14 Series F 60

    per DIN 43693

    1.16 Series 99

    Series 100

    1.1

    Multiple

    position

    switches

    series

    100

    62

    61

    72

    46

    40

    Single

    positionswitches

    series

    F 60

    99

    100

    1

    Accessories

    Spare parts

    5

    Contents

  • 8/3/2019 Balluff meccanici

    2/18

    Multiple position switches

    per DIN 43697 for

    standard applications

    Mounting and function

    dimensions per

    DIN 43697

    Dual-chamber system

    with IP 67 protection:

    wear-free membrane with

    hermetic sealing from

    plunger mechanism and

    switch chamber

    Maintenance-free, self-

    lubricating plunger guide

    with slide bearing

    Multiple position switches

    with anticrystillization

    plungers

    With chisel plungers only

    For use with aggressive,

    resinifying liquid media

    In dry areas with very fine

    chip presence

    Connection types

    S 80 or S 90 connector

    with standard wiring as

    normally-open, connector

    position right (see

    drawing). Observe

    permissible operating

    voltage for connectors

    (see page 5.13).

    Thread for cable fitting

    M251.5 on side and in

    flange (gaskets and plugs

    included)

    Available sizes

    No. of plungers 2 3 4 5 6 8 10 12 14 16

    l2 when l1 = 12 mm 70 80 90 105 120 140 170 200 240 240

    l1 = 16 mm 70 90 105 120 140 170 200 240

    no. of S 80 1 1 2 2 2

    connectors S 90 1 1 1 1 1 1 2 2 2 2

    dimensions in mm

    Plunger

    type

    12 12 mm

    16 16 mm

    Plunger

    spacing

    02 2

    03 3

    04 4

    ...

    D Chisel

    K Ball

    R Roller

    L Roller bearing

    E Anticrystalli-

    zation chisel

    plunger

    Ordering example:

    BNS 819-D02-D16-100-10-FE-S 80

    BNS 819-D_ _-_ _ _-100-10-_ _-_ _ _

    FD 6...60 V

    FE 90...250 V

    optional

    Function

    indication

    S 80 5-pin

    S 90 12-pin

    optional

    Connector

    No. of

    plungers

    Series 100per DIN 43697

    ElectromechanicalMultiple Position Switches

    Option: Add code for function

    indication and/or connector to

    part number.

    Multiple position switches

    with function indication

    Function indication for

    dual voltage range option

    1.2

  • 8/3/2019 Balluff meccanici

    3/18

    Type

    Plunger spacing

    Plunger type

    Plunger material

    Housing material

    Connection

    Ambient temperature range

    Degree of protection per IEC 60529

    Function indication

    Precision multiple position switches per DIN 43697

    12 mm or 16 mm

    chisel (D), ball (K), roller (R), roller bearing (L) or anticrystallization plungers (E)

    stainless steel, induction hardened

    cast aluminum, corrosion-resistant, anodized finish

    cable fitting M251.5 or connector

    5...+80 C

    IP 67

    LED 6...60 V (FD) or 90...250 V (FE)

    BSE 30.0

    BNS 819-D_ _-_ _ _-100-10-_ _-_ _ _

    silver, gold plated

    snap switch

    dual changeover, one normally-open and

    one normally-closed, galvanically isolated

    see page 5.2

    8 mm

    6 mm

    5.5 mm

    min. 20 N

    max. 300/min

    10 m/min

    8 m/min

    20 m/min

    120 m/min

    0.002 mm

    0.01 mm

    max. 100 g

    10...55 Hz 1.5 mm

    Caution!To ensure switchingfunction, the dimension5-0.5 is especially critical.

    With switch element

    Ordering code

    Wiring diagram, style

    Switch element

    Contact material

    Switching principle

    Contact system

    Electrical data

    Mechanical data

    Plunger point to reference surface

    Switchpoint to reference surfaceMaximum plunger travel

    Switching actuating force on plunger

    Switching frequency

    Approach plunger D, E

    velocity plunger K

    plunger R

    plunger L

    Repeata- plunger D, E, K

    bility plunger R, L

    Shock load

    Vibration

    Installation

    1

    5

    Series 100per DIN 43697

    ElectromechanicalMultiple Position Switches

    cam cam tray

    Multiple

    position

    switches

    series

    100

    62

    61

    72

    46

    40

    Single

    positionswitches

    series

    F 60

    99

    100

    Accessories

    Spare parts

    referencesurface

    gasket

    function indication

    anticrystallization chisel plungers (E)

    connector

    S 80

    connector

    S 90

    50(side

    ca

    bleen

    try

    )

    www.balluff.de 1.3

    Sensor systems AS-Interface

    Series 100 electromechanicalmultiple position switches with direct

    AS-Interface compatibilitycan be found in the maincatalog "The SensorLine" section 5.

    85(withFD/FE)

  • 8/3/2019 Balluff meccanici

    4/18

    Available sizes

    No. of plungers 2 3 4 5 6 8 10 12 14 16

    l2 when l1 = 12 mm 64 72 84 96 112 130 160 192 225 225

    l1 = 16 mm 64 84 96 112 130 160 192 225

    no. of S 80 1 1 2 2 2

    connectors S 90 1 1 1 1 1 1 2 2 2 2

    dimensions in mm

    Plunger

    type

    12 12 mm

    16 16 mm

    Plunger

    spacing

    02 2

    03 3

    04 4

    ...

    D Chisel

    K Ball

    R Roller

    L Roller bearing

    E Anticrystalli-

    zation chisel

    plunger

    Ordering example:

    BNS 819-D04-D12-62-10-FD-S 80

    BNS 819-D_ _-_ _ _-62-10-_ _-_ _ _

    FD 6...60 V

    FE 90...250 V

    optional

    Function

    indication

    S 80 5-pin

    S 90 12-pin

    optional

    Connector

    No. of

    plungers

    Series 62ElectromechanicalMultiple Position Switches

    Option: Add code for function

    indication and/or connector to

    part number.

    Multiple position switches

    for standard applications

    Dual-chamber system

    with IP 67 protection:

    wear-free membrane with

    hermetic sealing from

    plunger mechanism and

    switch chamber

    Maintenance-free, self-

    lubricating plunger guide

    with slide bearing

    Multiple position switches

    with anticrystillization

    plungers

    With chisel plungers only

    For use with aggressive,

    resinifying liquid media

    In dry areas with very fine

    chip presence

    Connection types

    S 80 or S 90 connector

    with standard wiring as

    normally-open, connector

    position right (see

    drawing). Observe

    permissible operating

    voltage for connectors

    (see page 5.13).

    Thread for cable fitting

    M201.5 on side and in

    flange (gaskets and plugs

    included)

    Multiple position switches

    with function indication

    Function indication for

    dual voltage range option

    1.4

  • 8/3/2019 Balluff meccanici

    5/18

    Multiple

    position

    switches

    series

    100

    62

    61

    72

    46

    40

    Single

    positionswitches

    series

    F 60

    99

    100

    Precision multiple position switches

    12 mm or 16 mm

    chisel (D), ball (K), roller (R), roller bearing (L) or anticrystallization plungers (E)

    stainless steel, induction hardened

    cast aluminum, corrosion-resistant, anodized finish

    cable fitting M201.5 or connector

    5...+80 C

    IP 67

    LED 6...60 V (FD) or 90...250 V (FE)

    Caution!

    To ensure switchingfunction, the dimension5-0.5 is especially critical.

    www.balluff.de

    1

    5

    Series 62ElectromechanicalMultiple Position Switches

    BSE 30.0

    BNS 819-D_ _-_ _ _-62-10-_ _-_ _ _

    silver, gold plated

    snap switch

    dual changeover, one normally-open and

    one normally-closed, galvanically isolated

    see page 5.2

    8 mm

    6 mm

    5.5 mm

    min. 20 N

    max. 300/min

    10 m/min

    8 m/min

    20 m/min

    120 m/min

    0.002 mm

    0.01 mm

    max. 100 g

    10...55 Hz 1.5 mm

    With switch element

    Ordering code

    Wiring diagram, style

    Switch element

    Contact material

    Switching principle

    Contact system

    Electrical data

    Mechanical data

    Plunger point to reference surface

    Switchpoint to reference surfaceMaximum plunger travel

    Switching actuating force on plunger

    Switching frequency

    Approach plunger D, E

    velocity plunger K

    plunger R

    plunger L

    Repeata- plunger D, E, K

    bility plunger R, L

    Shock load

    Vibration

    Installation

    Type

    Plunger spacing

    Plunger type

    Plunger material

    Housing material

    Connection

    Ambient temperature range

    Degree of protection per IEC 60529

    Function indication

    gasket

    function indication

    referencesurface

    cam cam tray

    Accessories

    Spare parts

    33(side

    ca

    bleen

    try

    )

    85(withFD/FE)

    1.5

    anticrystallization chisel plungers (E)

    connector

    S 80

    connector

    S 90

  • 8/3/2019 Balluff meccanici

    6/18

    Plunger

    type

    12 12 mm

    16 16 mm

    Plunger

    spacing

    B Standard

    2 M201.5

    on side

    B 3 M201.5

    on side and in

    flangeC 2 M201.5

    on side and cable

    entry in flange

    D Chisel

    K Ball

    R Roller

    L Roller

    bearing

    E Anticrystalli-zation chisel

    plunger

    Ordering example:

    BNS 819-B04-D12-61-12-10-FD-S 80

    BNS 819-_ _ _-_ _ _-61-_ _-10-_ _-_ _ _

    12 12 mm

    16 16 mm

    24 24 mm

    30 30 mm

    Distance I3

    FD 6...60 V

    FE 90...250 V

    optional

    Function

    indication

    Housing

    style

    Series 61ElectromechanicalMultiple Position Switches

    Option: Add code for function

    indication and/or connector to

    part number.

    S 80 5-pin

    optional

    Connector

    No. of

    connectors S 80

    1

    1

    2

    2

    2

    1

    1

    2

    Housing B

    standard dimension

    l2

    l3

    36 12

    48 12

    60 12

    72 12

    84 12

    48 16

    72 16

    84 16

    Housing B

    dimension

    l2

    l3

    60 30

    60 24

    60 30

    Housing C

    dimension

    l2

    l3

    48 24

    60 30

    60 24

    60 30

    02 2

    03 3

    04 4

    ...

    No. of

    plungers

    Available sizes

    Multiple position switches

    for standard applications

    Dual-chamber system

    with IP 67 protection:

    wear-free membrane with

    hermetic sealing from

    plunger mechanism and

    switch chamber

    Maintenance-free, self-

    lubricating plunger guide

    with slide bearing

    Multiple position switches

    with anticrystillization

    plungers

    With chisel plungers only

    For use with aggressive,

    resinifying liquid media

    In dry areas with very fine

    chip presence

    Connection types

    S 80 connector

    with standard wiring as

    normally-open, connector

    position right (see

    drawing). Observe

    permissible operating

    voltage for connector

    (see page 5.13).

    Plunger spacing

    dimension

    l112

    12

    12

    12

    12

    16

    16

    16

    1.6

    Thread for cable fitting

    M201.5 on side and in

    flange (gaskets and plugs

    included)

    Multiple position switches

    with function indication

    Function indication for

    dual voltage range option

    No. of

    plungers

    2

    3

    4

    5

    6

    2

    3

    4

    dimensions in mm

  • 8/3/2019 Balluff meccanici

    7/18

    Multiple

    position

    switches

    series

    100

    62

    61

    72

    46

    40

    Single

    positionswitches

    series

    F 60

    99

    100

    Type

    Plunger spacing

    Plunger type

    Plunger material

    Housing material

    Connection

    Ambient temperature range

    Degree of protection per IEC 60529

    Function indication

    Caution!

    To ensure switchingfunction, the dimension5-0.5 is especially critical.

    www.balluff.de

    1

    5

    Series 61ElectromechanicalMultiple Position Switches

    Precision multiple position switches

    12 mm or 16 mm

    chisel (D), ball (K), roller (R), roller bearing (L) or anticrystallization plungers (E)

    stainless steel, induction hardened

    cast aluminum, corrosion-resistant, anodized finish

    cable fitting M201.5 or connector5...+80 C

    IP 67

    LED 6...60 V (FD) or 90...250 V (FE)

    BSE 30.0

    BNS 819-_ _ _-_ _ _-61-_ _-10-_ _-_ _ _

    silver, gold plated

    snap switch

    dual changeover, one normally-open and

    one normally-closed, galvanically isolated

    see page 5.2

    8 mm

    6 mm

    5.5 mm

    min. 20 N

    max. 300/min

    10 m/min

    8 m/min

    20 m/min

    120 m/min

    0.002 mm

    0.01 mm

    max. 100 g

    10...55 Hz 1.5 mm

    With switch element

    Ordering code

    Wiring diagram, style

    Switch element

    Contact material

    Switching principle

    Contact system

    Electrical data

    Mechanical data

    Plunger point to reference surface

    Switchpoint to reference surfaceMaximum plunger travel

    Switching actuating force on plunger

    Switching frequency

    Approach plunger D, E

    velocity plunger K

    plunger R

    plunger L

    Repeata- plunger D, E, K

    bility plunger R, L

    Shock load

    Vibration

    Installation

    cam cam tray

    reference

    surface

    housing B housing Chousing B (standard)

    gasket

    anticrystallization chisel plungers (E)

    83(withFD/FE)

    Accessories

    Spare parts

    connector

    S 80

    1.7

    Sensor Systems AS-Interface

    Series 61 electromechanicalmultiple position switches with direct

    AS-Interface compatibilitycan be found in the maincatalog "The SensorLine" section 5.

  • 8/3/2019 Balluff meccanici

    8/18

    Series 72ElectromechanicalMultiple Position Switches

    Available sizes

    No. of plungers 2 3 4 5 6 8 10 12 13 16

    l2 when l1 = 12 mm 84 84 100 116 132 164 180 212 244l3 when l1 = 12 mm 66 66 82 98 114 146 162 194 226

    l4 when l1 = 12 mm 54 54 68 84 100 132 148 180 212

    l2 when l1 = 16 mm 84 100 116 132 148 180 212 244

    l3 when l1 = 16 mm 66 82 98 114 130 162 194 226

    l4 when l1 = 16 mm 54 68 84 100 116 148 180 212

    no. of S 80 1 1 2 2 2

    connectors S 90 1 1 1 1 1 1 2 2 2 2

    dimensions in mm

    Plunger

    type

    12 12 mm

    16 16 mm

    Plunger

    spacing

    02 2

    03 3

    04 4

    ...

    D Chisel

    K Ball

    R Roller

    L Roller bearing

    E Anticrystalli-

    zation chisel

    plunger

    Ordering example:

    BNS 819-B04-D12-72-10-FD

    BNS 819-B_ _-_ _ _-72-10-_ _

    FD 6...60 V

    FE 90...250 V

    optional

    Function

    indication

    No. of

    plungers

    Option: Add code for function

    indication to part number.

    Multiple position switches

    for standard applications

    Dual-chamber system

    with IP 67 protection:

    wear-free membrane with

    hermetic sealing from

    plunger mechanism and

    switch chamber

    Maintenance-free, self-

    lubricating plunger guide

    with slide bearing

    Multiple position switches

    with anticrystillization

    plungers

    With chisel plungers only

    For use with aggressive,

    resinifying liquid media

    In dry areas with very fine

    chip presence

    Connection types

    Thread for cable fitting

    M251.5 on side and in

    flange (gaskets and plugs

    included)

    1.8

    Multiple position switches

    with function indication

    Function indication for

    dual voltage range option

    Phase-Ou

    t!

  • 8/3/2019 Balluff meccanici

    9/18

    Precision multiple position switches

    12 mm or 16 mm

    chisel (D), ball (K), roller (R), roller bearing (L) or anticrystallization plungers (E)

    stainless steel, induction hardened

    cast aluminum, corrosion-resistant, anodized finish

    cable fitting M251.5 or connector

    5...+80 C

    IP 67

    LED 6...60 V (FD) or 90...250 V (FE)

    Type

    Plunger spacing

    Plunger type

    Plunger material

    Housing material

    Connection

    Ambient temperature range

    Degree of protection per IEC 60529

    Function indication

    Series 72ElectromechanicalMultiple Position Switches

    Multiple

    position

    switches

    series

    100

    62

    61

    72

    46

    40

    Single

    positionswitches

    series

    F 60

    99

    100

    1

    5

    Caution!To ensure switchingfunction, the dimension3-0.5 is especially critical.

    BSE 30.0

    BNS 819-B_ _-_ _ _-72-10-_ _-_ _ _

    silver, gold plated

    snap switch

    dual changeover, one normally-open and

    one normally-closed, galvanically isolated

    see page 5.2

    6 mm

    4 mm

    5.5 mm

    min. 20 N

    max. 300/min

    10 m/min

    8 m/min

    20 m/min

    120 m/min

    0.002 mm

    0.01 mm

    max. 100 g

    10...55 Hz 1.5 mm

    With switch element

    Ordering code

    Wiring diagram, style

    Switch element

    Contact material

    Switching principle

    Contact system

    Electrical data

    Mechanical data

    Plunger point to reference surface

    Switchpoint to reference surfaceMaximum plunger travel

    Switching actuating force on plunger

    Switching frequency

    Approach plunger D, E

    velocity plunger K

    plunger R

    plunger L

    Repeata- plunger D, E, K

    bility plunger R, L

    Shock load

    Vibration

    Installation

    Accessories

    Spare parts

    reference

    surface

    function

    indication

    center

    M251.5

    cam cam tray

    anticrystallization

    chisel plungers (E)87.5 (with FD/FE)

    1.9www.balluff.de

    Phase-Ou

    t!

  • 8/3/2019 Balluff meccanici

    10/18

    Series 46ElectromechanicalMultiple Position Switches

    Multiple position switches

    for standard applications

    Smallest plunger spacing

    for electromechanical

    multiple position switches

    (8 mm or 10 mm)

    Dual-chamber system

    with IP 67 protection:

    wear-free membrane with

    hermetic sealing from

    plunger mechanism and

    switch chamber

    Maintenance-free, self-

    lubricating plunger guide

    with slide bearing

    Multiple position switches

    with anticrystillization

    plungers

    With chisel plungers only

    For use with aggressive,

    resinifying liquid media

    In dry areas with very fine

    chip presence

    Connection types

    S 80 connector

    with standard wiring as

    normally-open, connector

    position right (see

    drawing). Observe

    permissible operating

    voltage for connector

    (see page 5.13).

    Thread for cable fitting

    M161.5 on side and in

    flange (gaskets and plugs

    included)

    Switch elements

    for applications with

    low currents

    For currents 10...100 mA

    snap switch types

    BSE 75 or BSE 76 are

    recommended. These switch

    elements can handle low

    power thanks to their special

    contact design and the use

    of gold-crosspoint as the

    contact material.

    Available sizes

    No. of plungers 2 3 4 5 6 8 10 12

    l2 when l1 = 8 mm 49 59 64 72 80 96 112 129

    l1 = 10 mm 49 59 72 80 89 112 129

    no. of connectors S 80 1 1 2 2 2

    dimensions in mm

    Plunger

    type

    08 8 mm

    10 10 mm

    Plunger

    spacing

    02 2

    03 3

    04 4

    ...

    D Chisel

    K Ball

    R Roller

    E Anticrystalli-

    zation chisel

    plunger

    Ordering example:BNS 819-B04-D08-46-11-S 80

    BNS 819-B_ _-_ _ _-46-1_-_ _ _

    0 BSE 71

    1 BSE 72

    2 BSE 75

    3 BSE 76

    4 BSE 77

    Switch

    elements

    No. of

    plungers

    Option: Add code for connector

    to part number.

    Function indication FC on request.

    S 80 5-pin

    optional

    Connector

    1.10

  • 8/3/2019 Balluff meccanici

    11/18

    Type

    Plunger spacing

    Plunger type

    Plunger material

    Housing material

    Connection

    Ambient temperature range

    Degree of protection per IEC 60529

    BSE 77BNS ...-46-14

    silver

    snap switch

    single-pole changeover

    plug-/solder connection

    see page 5.3

    4 mm

    3.5 mm

    3.5 mm

    min. 8 N

    max. 200/min

    8 m/min

    9 m/min

    60 m/min

    0.02 mm

    0.03 mm

    0.05 mm

    max. 100 g

    10...55 Hz 1.5 mm

    BSE 72 BSE 76

    BNS ...-46-11 BNS ...-46-13

    silver gold

    snap switch

    single-pole changeover

    screw connection

    see page 5.3

    4 mm

    3.5 mm

    3.5 mm

    min. 8 N

    max. 200/min

    8 m/min

    9 m/min

    60 m/min

    0.02 mm

    0.03 mm

    0.05 mm

    max. 100 g

    10...55 Hz 1.5 mm

    BSE 71 BSE 75

    BNS ...-46-10 BNS ...-46-12

    silver gold

    snap switch

    single-pole changeover

    solder connection

    see page 5.3

    4 mm

    3.5 mm

    3.5 mm

    min. 8 N

    max. 200/min

    8 m/min

    9 m/min

    60 m/min

    0.02 mm

    0.03 mm

    0.05 mm

    max. 100 g

    10...55 Hz 1.5 mm

    Precision multiple position switches

    8 mm or 10 mm

    chisel (D), ball (K), roller (R) or anticrystallization plungers (E)

    stainless steel, induction hardened

    cast aluminum, corrosion-resistant, anodized finish

    cable fitting M161.5 or connector

    5...+80 C

    IP 67

    Series 46ElectromechanicalMultiple Position Switches

    Multiple

    position

    switches

    series

    100

    62

    61

    72

    46

    40

    Single

    positionswitches

    series

    F 60

    99

    100

    1

    5

    With switch element

    Ordering code

    Wiring diagram, style

    Switch element

    Contact material

    Switching principle

    Contact system

    Connection type

    Electrical data

    Mechanical data

    Plunger point to reference surface

    Switchpoint to reference surfaceMaximum plunger travel

    Switching actuating force on plunger

    Switching frequency

    Approach plunger D, E

    velocity plunger K

    plunger R

    Repeatability plunger D, Eplunger K

    plunger R

    Shock load

    Vibration

    Caution!To ensure switchingfunction, the dimension2.8-0.5 is especially critical.

    cam cam tray

    referencesurface

    60(withBSE77)

    Installation

    anticrystallization chisel plungers (E)

    connector

    S 80

    Accessories

    Spare parts

    1.11www.balluff.de

  • 8/3/2019 Balluff meccanici

    12/18

    Series 40ElectromechanicalMultiple Position Switches

    Plunger

    type

    08 8 mm

    Plunger

    spacing

    02 2

    03 3

    04 4

    ...

    D Chisel

    K Ball

    R Roller

    E Anticrystalli-

    zation chisel

    plunger

    Ordering example:

    BNS 819-B04-D08-40-10-S 80

    BNS 819-B_ _-_ _ _-40-1_-_ _ _

    0 BSE 71

    1 BSE 72

    2 BSE 75

    3 BSE 76

    4 BSE 77

    Switch

    elements

    No. of

    plungers

    Option: Add code for connector

    to part number.

    S 80 5-pin

    optional

    Connector

    Multiple position switches

    for standard applications

    Smallest plunger spacing

    for electromechanical

    multiple position switches

    (8 mm)

    Dual-chamber system

    with IP 67 protection:

    wear-free membrane with

    hermetic sealing from

    plunger mechanism and

    switch chamber

    Maintenance-free, self-

    lubricating plunger guide

    with slide bearing

    Multiple position switches

    with anticrystillization

    plungers

    With chisel plungers only

    For use with aggressive,

    resinifying liquid media

    In dry areas with very fine

    chip presence

    Connection types

    S 80 connector

    with standard wiring as

    normally-open. Observe

    permissible operating

    voltage for connector

    (see page 5.13).

    Thread for cable fitting

    M161.5 on side (gaskets

    and plugs included)

    Switch elements

    for applications with

    low currents

    For currents 10...100 mA

    snap switch types

    BSE 75 or BSE 76 are

    recommended. These switch

    elements can handle low

    power thanks to their special

    contact design and the use

    of gold-crosspoint as the

    contact material.

    Available sizes

    No. of plungers 2 3 4 5 6

    l1 34 42 50 58 66

    no. of connectors S 80 1 1 2 2 2

    dimensions in mm

    1.12

  • 8/3/2019 Balluff meccanici

    13/18

    Type

    Plunger spacing

    Plunger type

    Plunger material

    Housing material

    Connection

    Ambient temperature range

    Degree of protection per IEC 60529

    Precision multiple position switches

    8 mm

    chisel (D), ball (K), roller (R) or anticrystallization plungers (E)

    stainless steel, induction hardened

    cast aluminum, corrosion-resistant, anodized finish

    cable fitting M161.5 on side or connector

    5...+80 C

    IP 67

    Series 40ElectromechanicalMultiple Position Switches

    Multiple

    position

    switches

    series

    100

    62

    61

    72

    46

    40

    Single

    positionswitches

    series

    F 60

    99

    100

    1

    5

    Caution!

    To ensure switchingfunction, the dimension2.8-0.5 is especially critical.

    cam cam trayInstallation

    reference

    surface

    anticrystallization chisel plungers (E)

    connector

    S 80

    BSE 77BNS ...-40-14

    silver

    snap switch

    single-pole changeover

    plug-/solder connection

    see page 5.3

    4 mm

    3.5 mm

    3.5 mm

    min. 8 N

    max. 200/min

    8 m/min

    9 m/min

    60 m/min

    0.02 mm

    0.03 mm

    0.05 mm

    max. 100 g

    10...55 Hz 1.5 mm

    BSE 72 BSE 76

    BNS ...-40-11 BNS ...-40-13

    silver gold

    snap switch

    single-pole changeover

    screw connection

    see page 5.3

    4 mm

    3.5 mm

    3.5 mm

    min. 8 N

    max. 200/min

    8 m/min

    9 m/min

    60 m/min

    0.02 mm

    0.03 mm

    0.05 mm

    max. 100 g

    10...55 Hz 1.5 mm

    BSE 71 BSE 75

    BNS ...-40-10 BNS ...-40-12

    silver gold

    snap switch

    single-pole changeover

    solder connection

    see page 5.3

    4 mm

    3.5 mm

    3.5 mm

    min. 8 N

    max. 200/min

    8 m/min

    9 m/min

    60 m/min

    0.02 mm

    0.03 mm

    0.05 mm

    max. 100 g

    10...55 Hz 1.5 mm

    With switch element

    Ordering code

    Wiring diagram, style

    Switch element

    Contact material

    Switching principle

    Contact system

    Connection type

    Electrical data

    Mechanical data

    Plunger point to reference surface

    Switchpoint to reference surfaceMaximum plunger travel

    Switching actuating force on plunger

    Switching frequency

    Approach plunger D, E

    velocity plunger K

    plunger R

    Repeatability plunger D, Eplunger K

    plunger R

    Shock load

    Vibration

    Accessories

    Spare parts

    1.13www.balluff.de

  • 8/3/2019 Balluff meccanici

    14/18

    Series F 60per DIN 43693

    ElectromechanicalSingle Position Switches

    D Chisel

    K Ball

    R Roller

    L Roller bearing

    E Anticrystalli-

    zation chisel

    plunger

    Ordering example:

    BNS 819-FD-60-101-FE-S 80

    BNS 819-F_-60-101-_ _-_ _ _

    FD 6...60 V

    FE 90...250 V

    optional

    Function

    indication

    Plunger

    type

    Option: Add code for function

    indication and/or connector to

    part number.

    S 80 5-pin

    optional

    Connector

    Single position switches

    per DIN 43693 for

    standard applications

    Mounting and function

    dimensions per

    DIN 43693

    Dual-chamber system

    with IP 67 protection:

    wear-free membrane with

    hermetic sealing from

    plunger mechanism and

    switch chamber

    Maintenance-free, self-

    lubricating plunger guide

    with slide bearing

    Plungers can be rotated

    in 4 approach directions

    (see page .8)

    Single position switches

    with anticrystillization

    plunger

    With chisel plunger only

    For use with aggressive,

    resinifying liquid media

    In dry areas with very fine

    chip presence

    Connection types

    S 80 connector

    with standard wiring as

    normally-open. Observe

    permissible operating

    voltage for connector

    (see page 5.13).

    Thread for cable fitting

    M161.5 (gaskets and

    plugs included)

    Single position switches

    with function indication

    Function indication for

    dual voltage range option

    1.14

  • 8/3/2019 Balluff meccanici

    15/18

    Type

    Plunger type

    Plunger material

    Housing material

    Connection

    Ambient temperature range

    Degree of protection per IEC 60529

    Function indication

    Precision single position switches per DIN 43693

    chisel (D), ball (K), roller (R), roller bearing (L) or anticrystallization plungers (E)

    stainless steel, induction hardened

    cast aluminum, corrosion-resistant, anodized finish

    cable fitting M161.5 or connector

    5...+80 C

    IP 67

    LED 6...60 V (FD) or 90...250 V (FE)

    Series F 60per DIN 43693

    ElectromechanicalSingle Position Switches

    reference

    surface

    connector

    S 80

    anticrystallization

    chisel plunger (E)

    function indication

    Multiple

    position

    switches

    series

    100

    62

    61

    72

    46

    40

    Single

    positionswitches

    series

    F 60

    99

    100

    1

    5

    Caution!

    To ensure switchingfunction, the dimension5-0.5 is especially critical.

    BSE 30.0

    BNS 819-F_-60-101-_ _-_ _ _

    silver, gold plated

    snap switch

    dual changeover, one normally-open and

    one normally-closed, galvanically isolated

    see page 5.2

    8 mm

    4 mm

    7,5 mm

    min. 20 N

    max. 300/min

    10 m/min

    8 m/min

    20 m/min

    120 m/min

    0.002 mm

    0.01 mm

    max. 100 g

    10...55 Hz 1.5 mm

    With switch element

    Ordering code

    Wiring diagram, style

    Switch element

    Contact material

    Switching principle

    Contact system

    Electrical data

    Mechanical data

    Plunger point to reference surface

    Switchpoint to reference surfaceMaximum plunger travel

    Switching actuating force on plunger

    Switching frequency

    Approach plunger D, E

    velocity plunger K

    plunger R

    plunger L

    Repeata- plunger D, E, K

    bility plunger R, L

    Shock load

    Vibration

    Installationcam cam tray

    Accessories

    Spare parts

    76(withFD/FE)

    1.15www.balluff.de

  • 8/3/2019 Balluff meccanici

    16/18

    Series 99 and 100ElectromechanicalSingle Position Switches

    Single position switches

    for standard applications

    Dual-chamber system

    with IP 67 protection:

    wear-free membrane with

    hermetic sealing from

    plunger mechanism and

    switch chamber

    Maintenance-free, self-

    lubricating plunger guide

    with slide bearing

    Plungers can be rotated

    in 4 approach directions

    (see page .8)

    Single position switches

    with anticrystillization

    plunger

    With chisel plunger only

    For use with aggressive,

    resinifying liquid media

    In dry areas with very fine

    chip presence

    Connection types

    S 80 connector

    with standard wiring as

    normally-open. Observe

    permissible operating

    voltage for connector

    (see page 5.13).

    Thread for cable fitting

    M121.5 for series 99,

    thread for cable fitting

    M161.5 for series 100

    Switch elements

    for applications with

    low currents

    For currents 10...100 mA

    snap switch types

    BSE 73 or BSE 74 are

    recommended. These switch

    elements can handle low

    power thanks to their special

    contact design and the use

    of gold-crosspoint as the

    contact material.

    Plunger

    type

    0 BSE 69

    1 BSE 70

    2 BSE 73

    3 BSE 74

    Switch

    elements

    99 Series 99

    100 Series 100

    D Chisel

    K Ball

    R Roller

    E Anticrystalli-

    zation chisel

    plunger

    Ordering example:

    BNS 819-100-E-12-S 80

    BNS 819-_ _ _-_-1_-_ _ _

    Series

    S 80 only with BSE 69 or BSE 73.

    Option: Add code for connector

    to ordering code.

    S 80 5-pin

    optional

    Connector

    1.16

  • 8/3/2019 Balluff meccanici

    17/18

    Precision single position switches

    chisel (D), ball (K), roller (R) or anticrystallization plungers (E)

    stainless steel, induction hardened

    cast aluminum, corrosion-resistant, anodized finish

    cable fitting (M121.5 series 99, M161.5 series 100) or connector

    5...+80 C

    IP 67

    Type

    Plunger type

    Plunger material

    Housing material

    Connection

    Ambient temperature range

    Degree of protection per IEC 60529

    Series 99 and 100ElectromechanicalSingle Position Switches

    Caution!To ensure switchingfunction, the dimension2.8-0.5 is especially critical.

    cam cam trayInstallation

    Multiple

    position

    switches

    series

    100

    62

    61

    72

    46

    40

    Single

    positionswitches

    series

    F 60

    99

    100

    1

    5

    connector

    S 80

    anticrystallization

    chisel plunger (E)

    40 (series 99)

    42 (series 100)

    reference

    surface

    43

    so

    lderconnec

    tion

    47

    screwc

    onnection

    20 (series 99)22 (series 100)

    plugs for

    M12x1.5 (series 99)

    BSE 70 BSE 74

    BNS 819-99/100-_-11 BNS 819-99/100-_-13

    silver gold

    snap switch

    single-pole changeover

    screw connection

    see page 5.3

    4 mm

    3.5 mm

    3.5 mm

    min. 8 N

    max. 200/min

    8 m/min

    9 m/min

    60 m/min

    0.02 mm

    0.03 mm

    0.05 mm

    max. 100 g

    10...55 Hz 1.5 mm

    BSE 69 BSE 73

    BNS 819-99/100-_-10 BNS 819-99/100-_-12

    silver gold

    snap switch

    single-pole changeover

    solder connection

    see page 5.3

    4 mm

    3.5 mm

    3.5 mm

    min. 8 N

    max. 200/min

    8 m/min

    9 m/min

    60 m/min

    0.02 mm

    0.03 mm

    0.05 mm

    max. 100 g

    10...55 Hz 1.5 mm

    With switch element

    Ordering code

    Wiring diagram, style

    Switch element

    Contact material

    Switching principle

    Contact system

    Connection type

    Electrical data

    Mechanical data

    Plunger point to reference surface

    Switchpoint to reference surfaceMaximum plunger travel

    Switching actuating force on plunger

    Switching frequency

    Approach plunger D, E

    velocity plunger K

    plunger R

    Repeatability plunger D, Eplunger K

    plunger R

    Shock load

    Vibration

    Accessories

    Spare parts

    1.17www.balluff.de

    M16x1.5 (series 100)

  • 8/3/2019 Balluff meccanici

    18/18

    BalluffSensors

    Optimized forevery Automation Task