Canovate Balistik Sistemler ; is a Canovate Group company.
Canovate Balistik Sistemler combined with one of the world’s most renowned producers “ARMOUR SHIELD” company with international certification and have created the “CANOVATEARMOURSHIELD” brand by adding logos to the name.
Canovate and Armour Shield are now combined to deliver 40 years of technological know-how and experience.
Canovate’s best practices are applied to the manufacturing of Bulletproof Vests and Ballistic Protective Systems as well as a wide range of related products to meet various operational safetly requirements.
Each product and every system of products has been carefully designed and field proven to perform at the highest level of safety with full performance delivered at the lowest price point.
Company Profile
COVERT LINE LIGHTWEIGHT TACTICAL
OPTIONS & ACCESSORIESExtra body protection | HV armour insert plates | armoured shields |
armour blankets | bomb/mine disposal | armoured bags HV & LV
MILITARY LINE
www.canovateballistic.com [email protected]
COVERT LINE
COV
• Full Concealable• Lightweight• Ideal for Covert Operations• Various Levels of Protection• Built-in Blunt Trauma Shield• Special Female Models
(Covert Body Armour)
COVERT LINE
DCV• Full Concealable• Ultra-Lightweight• Ideal for VIP’s, Dignatories• Various Levels of Protection• Built-in Blunt Trauma Shield• Special Female Models
www.canovateballistic.com [email protected]
LIGHTWEIGHT TACTICAL LINE
SCO• Lightweight• Adjustable at Sides and Shoulders• Various Levels of Protection• Includes Patented Blunt Trauma Shield• Upgrade Plate Pockets Front and Back• Cost Effective Model
LIGHTWEIGHT TACTICAL LINE
TAC CON• Lightweight• Full Shoulder / Height Adjustment• Hard Wearing & Heavy Duty Outer Fabric• Spacer Mesh For Added Comfort• Various Levels of Protection• Includes Patented Blunt Trauma Shield• Upgrade Plate Pockets Front and Back
www.canovateballistic.com [email protected]
MILITARY LINE
CBT• Full Shoulder / Height Adjustment• Hard Wearing & Heavy Duty Outer Fabric• Spacer Mesh For Added Comfort• Molle Attachment System• 5 Built-in Double Magazine Pouches• Man Down Strap• Includes Armourshield Patented Blunt Trauma Shield• Upgrade Plate Pockets
MILITARY LINE
ANA• Lightweight• Molle Attachment System• Various Levels of Protection• Includes Armourshield Patented Blunt Trauma
Shield• Upgrade Plate Pockets• In Full Operational Use• Over 125,000 in operational use in Afghanistan
both police and military. (Police outer carrier in blue Cordura)
www.canovateballistic.com [email protected]
OPTIONS & ACCESSORIES
BODY ARMOUR OPTIONS
ThroatProtector
BicepsProtectors
GroinProtector
SideProtectors
O&A - BODY ARMOUR OPTIONS
www.canovateballistic.com [email protected]
MILITARY LINE - ANA
• Ultra Lightweight 100% polyethylene insert plate• Each plate comprises a high pressure Polyethylene
composite high laminate• High Velocity Protection - Level III / III+• Designed to be used in conjunction with the
appropriate NIJ level IIIA soft body armour inserts
OPTIONS & ACCESSORIES
UDR SERIES UPGRADE PLATE (Level III / Level III+)
HARD ARMOUR UPGRADE PLATE
• Ceramic Composite Upgrade Plate• High Velocity Protection - Level III / IV• Available in a Range Of Sizes Including Side
Plates• Single Curve / Multi Curve• In Excess of 400,000 in Operational Use• A Very Low Cost Solution to Meet All Needs
OPTIONS & ACCESSORIES
GR SERIES UPGRADE PLATE (Certified Level III & IV)
GR SERIES
UDR SERIES
HARD ARMOUR UPGRADE PLATE
www.canovateballistic.com [email protected]
O&A - ADDITIONAL PRODUCTS
OPTIONS & ACCESSORIES
ADDITIONAL PRODUCTS
BallisticDischargeBags
SideBlankets
Ballistic Shields
BALLISTIC HELMET
• Widely Used by Military and Law Enforcement• Maximum Reliability and Comfort• 3 Point Attachment with Adjustable Harness• Snap Fit and Quick Release Chin• Available in a Variety of Colours• NIJ Level IIIA - 9mm and 0.44 Magnum• V50 of > 620 m/s against 17 Grain Fragment
according to MIL-STD-662F
OPTIONS & ACCESSORIES
NIJ Level IIIA Ballistic Helmet
PASGT SERIES
www.canovateballistic.com [email protected]
BLUNT TRAUMA SHIELD
CANOVATEARMOURSHIELD ADVANTAGE
Ballistic Fabrics
Blunt Trauma Shield
• Proven High Quality Materials• NIJ Certification• Full Traceability• Over 30 Years Of Armour
Experience
• Unique Trauma Attenuation• Protects Vital Organs• Reduction of BT By Up To 70%• Little Additional of Movement• Worldwide Patents• Standard in
CANOVATEARMOURSHIELD Body Armour
9MM 124 GR. FMJ @ 5 METRES
BTSBTSWITHOUT WITH
PATENTEDWORLDWIDE
W O RL D WIDE
www.canovateballistic.com [email protected]
• Enabling ranges from “gun to target” with measurement and analysis of armour, materials, and ammunition performance
• Testing to All International Standards• Test guns; small caliber to 40 mm &
Barrels• Quality Control Checks on Materials And
Systems• Manufacturers Quality Testing (MQT)• Evaluation of New Materials• Development of New and Improved
Armour Packages• Unique Usage of Real Weapons• Measurement Systems - Velocity - Pressure - Rate of Fire - Accuracy
IN-HOUSE BALLISTIC TESTING LABORATORY - TESTING OF IN-SERVICE ARMOUR
www.canovateballistic.com [email protected]
Certificates
National Institute Of Justice Compliance test Report
CERTIFICATES AND TEST REPORTS
Mr Mike SankeyArmorshield LLC405 Heron DriveBridgeport, NJ 08014
April 14, 2005
Dear Mr. Sankey,
In accordance with your instructions, United States Test Laboratory conducted Ballistic Resistance Test of four complete sets of body armor of Armorshield LLC, Model AS-VGT3-3A, Lot 1103,which were received on March 31, 2005. Testing was not witnessed by representatives of NLECTC.Testing was not witnessed by a representative of Armorshield LLC.
The testing, which was authorized by NLECTC, was conducted in accordance with the requirements of NIJ Standard-0101.04, Ballistic Resistance Testing of Police Body Armor, dated September, 2000, and all changes, verbal and written, authorized by NLECTC as of the date of the testing. The results of this test are to be used to determine the compliance of the armor in conjunction with the U. S. Department of Justice’s voluntary compliance testing program for armor intended for use by Law Enforcement officers. United States Test Laboratory is not empowered to issue or deny this compliance status; however, the attached data indicates that this sampling of Model AS-VGT3-3A, Lot 1103, did satisfy the ballistic requirement of NIJ Standard-0101.04 prerequisites to issuance of compliance status for threat level 3A protection.
The test samples and a copy of this report are being forwarded to NLECTC, and you may expect their formal notification promptly. Please refer to USTL report number 05N048.
Sincerely,
Richard MouserPresident
Mr Mike SankeyArmorshield LLC405 Heron DriveBridgeport, NJ 08014
April 14, 2005
Dear Mr. Sankey,
In accordance with your instructions, United States Test Laboratory conducted Ballistic Resistance Test of four complete sets of body armor of Armorshield LLC, Model AS-VGT3-3A, Lot 1103,which were received on March 31, 2005. Testing was not witnessed by representatives of NLECTC.Testing was not witnessed by a representative of Armorshield LLC.
The testing, which was authorized by NLECTC, was conducted in accordance with the requirements of NIJ Standard-0101.04, Ballistic Resistance Testing of Police Body Armor, dated September, 2000, and all changes, verbal and written, authorized by NLECTC as of the date of the testing. The results of this test are to be used to determine the compliance of the armor in conjunction with the U. S. Department of Justice’s voluntary compliance testing program for armor intended for use by Law Enforcement officers. United States Test Laboratory is not empowered to issue or deny this compliance status; however, the attached data indicates that this sampling of Model AS-VGT3-3A, Lot 1103, did satisfy the ballistic requirement of NIJ Standard-0101.04 prerequisites to issuance of compliance status for threat level 3A protection.
The test samples and a copy of this report are being forwarded to NLECTC, and you may expect their formal notification promptly. Please refer to USTL report number 05N048.
Sincerely,
Richard MouserPresident
NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT
NIJ Standard 0101.04September 2000
FACILITY DESCRIPTION: TESTING CERTIFICATION:
Test Laboratory: Report Number: 05N048 Laboratory Representative: Witnessed by:Test Start Date: 04/04/05 Report Date: 04/04/05 Name Name
RepresentingARMOR DESCRIPTION:
Manufacturer: Model:Date Rec'd: 03/31/05 Aramid PBO Ceramic Metal Style: NIJ Armor Type: 3A Enter as: 1, 2A, 2, 3A, 3, 4, or Special
*Ballistic Material: Polyethylene Hybrid Composite Other Male/Female: NIJ STD-0101.03 Compliant: No
SAMPLE DESCRIPTION:
Front Back Front Back Front Back Front Back Front Back Front Back Front Back Front Back Front Back Front BackSize: LARGE LARGE LARGE LARGE LARGE LARGE LARGE LARGE LARGE LARGE
Panel Serial Number: 23096305 23096305 23096304 23096304 23096303 23096303 23096301 23096301 23096302 23096302Plate Serial Number: N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Lot Number: 002 002 002 002 002 002 002 002 002 002Gross Weight (lb.): 3.75 4.35 3.76 4.34 3.74 4.36 3.74 4.34 3.74 4.34
TEST DESCRIPTION:
Front Back Front Back Front Back Front Back Front Back Front Back Front Back Front Back Front Back Front BackTest Condition: Wet Wet Wet Wet Wet Wet Wet Wet Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry
Threat Ammunition: 9mm 9mm 9mm 9mm .44 Mag .44 Mag .44 Mag .44 Mag 9mm 9mm 9mm 9mm 9mm 9mm 9mm 9mm 9mm 9mm 9mm 9mmBullet (grain/type): 124/FMJ 124/FMJ 124/FMJ 124/FMJ 240/SJHP 240/SJHP 240/SJHP 240/SJHP 124/FMJ 124/FMJ 124/FMJ 124/FMJ 124/FMJ 124/FMJ 124/FMJ 124/FMJ 124/FMJ 124/FMJ 124/FMJ 124/FMJ
NIJ Reference Velocity (ft/s): 1430 1430 1430 1430 1430 1430 1430 1430 1430 1430 1430 1430 1430 1430 1430 1430 1430 1430 1430 1430Provided BL Lower Velocity (ft/s):
Bullet Manufacturer: Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem.Bullet Lot Number: 23558 23558 23558 23558 22847 22847 22847 22847 23558 23558 23558 23558 23558 23558 23558 23558 23558 23558 23558 23558
Test Barrel Manufacturer: H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S Test Barrel Length (in): 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0
ARMOR CONSTRUCTION: Front Panel Rear Panel
Front Closure (Y/N): N N
Removable Carrier (Y/N): Y Y
Number of Layers:
Description of Stitching:
Individual Layer Description:
REMARKS:
United States Test Laboratory, LLC
Sample 1 Sample 2 Sample 3 Sample 5Penetration-Backface Signature (P-BFS)
Sample 4 Sample 9
Sample 8 Sample 9 Sample 10Penetration-Backface Signature (P-BFS) Baseline Ballistic Limit
Hybrid
ArmorShield LLC AS-VGT3-3AN/AMale
Layers 1-24: Flex aramid film.Layers 25-28: Plastic (0.014" thick).Layers 29: Foam (0.157" thick).
Sample 6 Sample 7 Sample 8
Richard W. Mouser
COMPLIANCE TESTING INFORMATION
*Ballistic Material Choices
Sample 10Baseline Ballistic Limit
Layers 1-24: 3" horizontal bar tack at top center and bottom center.
Layers 1-24: Flex aramid film.Layers 25-28: Plastic (0.014" thick).Layers 29: Foam (0.157" thick).
Layers 1-24: 3" horizontal bar tack at top center and bottom center.
Sample 6 Sample 7
29 29
Sample 1 Sample 2 Sample 3 Sample 4 Sample 5
05N048.xls Information
NATIONAL INSTITUTE OF JUSTICECOMPLIANCE TEST REPORT
NIJ Standard 0101.04September 2000
FACILITY DESCRIPTION: TESTING CERTIFICATION:
Test Laboratory: Report Number: 06N074 Laboratory Representative: Witnessed by:Test Start Date: 06/07/06 Report Date: 06/07/06 Name Name
RepresentingARMOR DESCRIPTION:
Manufacturer: Model:Date Rec'd: 05/17/06 Aramid PBO Ceramic Metal Style: NIJ Armor Type: 4 Enter as: 1, 2A, 2, 3A, 3, 4, or Special
*Ballistic Material: Polyethylene Hybrid Composite Other Male/Female: NIJ STD-0101.03 Compliant: No
SAMPLE DESCRIPTION:
Front Back Front Back Front Back Front Back Front Back Front Back Front Back Front Back Front Back Front BackSize: See Remarks See Remarks See Remarks See Remarks See Remarks See Remarks See Remarks See Remarks See Remarks
Panel Serial Number: *0001 *0001 *0005 *0002 *0002 *0004 *0004 *0003 *0003Plate Serial Number: *0002 *0001 *0009 *0004 *0003 *0007 *0008 *0006 *0005
Lot Number: See Remarks See Remaks See Remarks See Remarks See Remarks See Remarks See Remarks See Remarks See RemarksGross Weight (lb.): 10.14 10.17 10.13 10.18 10.26 10.03 10.16 10.07 10.15
TEST DESCRIPTION:
Front Back Front Back Front Back Front Back Front Back Front Back Front Back Front Back Front Back Front BackTest Condition: Wet Wet Wet Wet Wet Wet Wet Wet Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry
Threat Ammunition: .30 Caliber .30 Caliber .30 Caliber .30 Caliber .30 Caliber .30 Caliber .30 Caliber .30 Caliber .30 Caliber .30 Caliber .30 Caliber .30 Caliber .30 Caliber .30 Caliber .30 Caliber .30 CaliberBullet (grain/type): 166/AP 166/AP 166/AP 166/AP 166/M2 AP 166/M2 AP 166/M2 AP 166/M2 AP 166/M2 AP 166/M2 AP 166/M2 AP 166/M2 AP 166/M2 AP 166/M2 AP 166/M2 AP 166/M2 AP
NIJ Reference Velocity (ft/s): 2880 2880 2880 2880 2880 2880 2880 2880 2880 2880 2880 2880 2880 2880Provided BL Lower Velocity (ft/s):
Bullet Manufacturer: Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem. Rem.Bullet Lot Number: 23558 23558 23558 23558 22847 22847 22847 22847 23558 23558 23558 23558 23558 23558 23558 23558 23558 23558 23558 23558
Test Barrel Manufacturer: H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S H.S Test Barrel Length (in): 24.0 24.0 24.0 24.0 0.0 0.0 0.0 0.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0
ARMOR CONSTRUCTION: Front Panel Rear Panel
Front Closure (Y/N): N N
Removable Carrier (Y/N): Y Y
Number of Layers:
Description of Stitching:
Individual Layer Description:
REMARKS:
United States Test Laboratory, LLC
Sample 1 Sample 2 Sample 3 Sample 5Penetration-Backface Signature (P-BFS)
Sample 4 Sample 9
Sample 8 Sample 9 Sample 10Penetration-Backface Signature (P-BFS) Baseline Ballistic Limit
Hybrid
Armor Shield, LLCN/AMale
See Remarks
Plate:Layer 1: Ceramic (0.52" thick).Panel:Layers 1-24: Flex woven aramid film.Layers 25-28: Plastic (0.14" thick).Layer 29: Foam (0.157" thick).
Sample 6 Sample 7 Sample 8
Richard W. Mouser
COMPLIANCE TESTING INFORMATION
Model #: 1012-GR-4 in conjunction with AS-VGT3-3A.*Plate SN#: 1006060002/0001; Plate Size: 10"x 12"; Lot# 100606.*
Panel SN#: 1006060001; Panel Size: LARGE; Lot# 4444.
*Ballistic Material Choices
Sample 10Baseline Ballistic Limit
Layers 1-24: 3" horizontal bar tack at top center and bottom center.
Plate:Layer 1: Ceramic (0.52" thick).Panel:Layers 1-24: Flex woven aramid film.Layers 25-28: Plastic (0.14" thick).Layer 29: Foam (0.157" thick).
Layers 1-24: 3" horizontal bar tack at top center and bottom center.
Sample 6 Sample 7
1+29 1+29
Sample 1 Sample 2 Sample 3 Sample 4 Sample 5
06N074.xls Information
Mr Mike SankeyArmorshield LLC405 Heron DriveBridgeport, NJ 08014
April 14, 2005
Dear Mr. Sankey,
In accordance with your instructions, United States Test Laboratory conducted Ballistic Resistance Test of four complete sets of body armor of Armorshield LLC, Model AS-VGT3-3A, Lot 1103,which were received on March 31, 2005. Testing was not witnessed by representatives of NLECTC.Testing was not witnessed by a representative of Armorshield LLC.
The testing, which was authorized by NLECTC, was conducted in accordance with the requirements of NIJ Standard-0101.04, Ballistic Resistance Testing of Police Body Armor, dated September, 2000, and all changes, verbal and written, authorized by NLECTC as of the date of the testing. The results of this test are to be used to determine the compliance of the armor in conjunction with the U. S. Department of Justice’s voluntary compliance testing program for armor intended for use by Law Enforcement officers. United States Test Laboratory is not empowered to issue or deny this compliance status; however, the attached data indicates that this sampling of Model AS-VGT3-3A, Lot 1103, did satisfy the ballistic requirement of NIJ Standard-0101.04 prerequisites to issuance of compliance status for threat level 3A protection.
The test samples and a copy of this report are being forwarded to NLECTC, and you may expect their formal notification promptly. Please refer to USTL report number 05N048.
Sincerely,
Richard MouserPresident
Mr Mike SankeyArmorshield LLC405 Heron DriveBridgeport, NJ 08014
June 14, 2006
Dear Mr. Sankey,
In accordance with your instructions, United States Test Laboratory conducted Ballistic Resistance Test of four complete sets of body armor of Armorshield LLC, Model 1012-GR-4, Lot 1205/1205,which were received on May 17, 2006. Testing was not witnessed by representatives of NLECTC.Testing was not witnessed by a representative of Armorshield LLC.
The testing, which was authorized by NLECTC, was conducted in accordance with the requirements of NIJ Standard-0101.04, Ballistic Resistance Testing of Police Body Armor, dated September, 2000, and all changes, verbal and written, authorized by NLECTC as of the date of the testing. The results of this test are to be used to determine the compliance of the armor in conjunction with the U. S. Department of Justice’s voluntary compliance testing program for armor intended for use by Law Enforcement officers. United States Test Laboratory is not empowered to issue or deny this compliance status; however, the attached data indicates that this sampling of Model 1012-GR-4 w/AS-VGT3-3A, Lot 1205/1205, did satisfy the ballistic requirement of NIJ Standard-0101.04 prerequisites to issuance of compliance status for threat level 4 protection. A complete ballistic limit test was not completed. A complete penetration could not be achieved at the elevated velocities. The ballistic limit test was terminated when excessive chamber pressures occurred.
The test samples and a copy of this report are being forwarded to NLECTC, and you may expecttheir formal notification promptly. Please refer to USTL report number 06N074.
Sincerely,
Richard MouserPresident
BALLISTIC SYSTEMS
Canovate Balistik Sistemleri A.Ş.Ekşioğlu Mah. Atabey Cad. No:12 Çekmeköy, İstanbul, TR 34794
Phone: +90 (216) 484 22 22 Fax: +90 (216) 484 05 06
www.canovateballistic.com [email protected]