136
Ballast and Lighting Control FAGERHULT 2006

Ballast and Lighting Control FAGERHULT 2006 - EVU MWG April 07 Swe... · Luxmate Instabus. Lighting control; divided how? EIB ECHLON DMX 1-10V DSI DALI 0-10V PWM ... •All suppliers

  • Upload
    ngodat

  • View
    213

  • Download
    0

Embed Size (px)

Citation preview

Ballast and Lighting Control

FAGERHULT 2006

DEVELOPMENT

1940Automobile

Telephone

Ballast

1950

Telephone

Automobile

Ballast

1960

Telephone

Automobile

Ballast

1970

Telephone

Automobile

Ballast

1980

Telephone

Automobile

Ballast

1984Tidig variant av hf-don med magnetiska filter

1990

Telephone

Ballast

Automobile

En enhet enklare koppling, lägre energiförlust.

2000

Telephone

Automobile

Ballast

…1…2…3…4…5

Låg profil, multifunktion, olika belastningar, processor kontroll och DALI

…6

Ett gammalt hf-don väger 3,5 gånger fler än nya

Dimmable light sourses

Incandescent lamps and halogen,

tungsten

Dimming range 0-100%

Dimming extends lamp life (5% of dimming doubles the

life time.)

Dimming = energy saving

Any kind of dimming technology works

Big loads can get a humming noise from the filament

38mm Fluorescent tube

Dimming range 20-100% depending on tube (standard or

rapid start)

Used in old applications. Dimmer with thyristor dimmer

and pre-heat transformer or old electronic gear.

The inductive load stops the dimmer from being fully

used.

Flickering light with pre-heat transformer

Dimmer must be made for inductive loads

26mm Fluorescent tube

Dimming range 1-100%

Dimming with 1-10V, DSI or DALI.

Early dimming technology was made with

electronic pre-heat units and conventional ballasts.

This was not a HF-dimming. It easily caused

flickering light.

Compact tubesOnly compact tubes with 4 pins are dimmable.

Dimming range 5-100%.

Needs electronic ballast for dimming

Small compact tubes

Incandescent replacement

Small energy saving flourecent lamps has electronic gear

built in. The electronics main focus is to maintain a stabile

and flicker free output. This is a contradiction to dimming.

Do not dim. The capacitive load can break the dimmer.

T5 Fluorescent tube

Dimming range 1-100%

Works only with electronic ballast .

Also as circular tube

Mercury lamps

Dimming range 60-100%

Only lamps without capasitor are dimmable

Dimming shortens lamp life

Lamps need to start at 100% for 10 minutes before

dimming

Dimming must be slow, no fast change

New technology with electronic ballasts will make

dimming possible in near future

High pressure sodium

Dimming range 50-100%, lower for short periods

Only lamps without capasitor are dimmable

Dimming shortens lamp life

Lamps need to start at 100% for 10 minutes before

dimming

Dimming must be slow, no fast change

Metal Halide

Dimming range 50-100%,

Dimming affects light colour

Flickers easily during dimming

Only lamps without capasitor are dimmable

Dimming shortens lamp life

Lamps need to start at 100% for 10 minutes before

dimming

Dimming must be slow, no fast change

Low pressure sodium

No

NEON cold cathodeDimming range 5-100%

Dimming with conventional transformer

Electronic transformer for DMX protocol are available

LED

Dimming range 0-100% (voltage control)

Dimming with special electronic transformers or converters

Dimming with pulse or voltage control

9 out of 10 do not know that

fluorescent light is dimmable

But no one would accept a radio without a volume control…

Different ways of dimming

230V

Dimmable hf-ballasts

230V 12V

Thyristor dimming

Thyristor dimming is the most common way of controlling

a resitive or inductive load. Also know as leading edge

dimming.

Noise reduction is needed.

Creates massive harmonics on mains.

A coil is used to reduce voltage spikes.

Dimmer size from 300VA -5500VA.

230V

Leading edge

dimming

Dimming circuit Filter choke

Thyristor dimming

Dimmer for

control with

external switch

250VA

Dimmer for

domestic use

Wallbox mounted

300-1000VA

Universaldimmer

DIN-rail mounting

500-2000VA Dimmer for large

loads

2200-5500VA

230V

Transistor dimming

Transistordimming also known as trailing edge dimming. A

more complicated way of dimming, but with good result.

Dimms without any noise and are useful in sensitive

installations.

Dimms resitive and capasitive loads.

Creates harmonic distubance om mains.

Transistor dimmers are often used for dimming electronic

transformers.

Shall not be used for dimming conventional transformers!

Dimmers from 300VA -2200VA.

230V 12V

Electronic transformer

230V

Trailing edge

dimming

Dimming circuit

Transistor dimming

230V

SINEWAVE DIMMING

Sinewave dimming is the latest invention in dimming

technology. The energy input is sampled at a high

frequency and controlled out with a lower volt/current;

very much like amplitude control from a Variac

transformer!

The first electronic dimmer that do not creats harmonics!

Phase Input Phase Out

DIMMS EVERYTHING!

The output current waveform is smoothed using a

passive network to produce an output waveform

that accurately represents the waveform profile of

the incoming supply. The PWM process adds less

than 1% distortion to the mains supply, resulting in

a completely silent dimmer with a remarkable

facility for dimming almost any load.

Overall benefits of Sine Wave dimming:

Lamp filament noise eliminated

Extended lamp life due to elimination of load switching and

reduced peak voltage

Less than 1% harmonic distortion reduces power costs

Unity Power Factor

Minimum 96.5% efficiency to a maximum of 99%

"Any load" operation (dims the widest variety of loads of any

dimmer)

Total short-circuit and overload protection without breaker tripping

230V

STEP TRANSFORMER

Step transformer only reduces the main voltage to a lower

level of aprox. 200V. It is ment for energy saving in

installations with konventional ballats and starters.

A typical application are storage, corridors

Phase Input Phase Out

DIMMS(?) EVERYTHING!

BADLY!

200V

Lighting control; how?

EIBECHLON

DMX

DSI

DALI

1-10V

0-10VPWM

20V current control

BATIBUS

RS232

RS485

IHC X10IR command

C-busTransistor dimming

Tyristor dimming

Sinewave dimming

RF control

And about 20 more…

Switch Control

Step transformer

Luxmate

Instabus

Lighting control; divided how?

EIB ECHLON

DMX

DSI DALI1-10V

0-10V PWM

20V current controlBATIBUS

RS232 RS485

IHC

X10

IR command

C-bus

Transistor dimming

Tyristor dimming Sinewave dimming

RF control

BMS

Theatre

HF-Ballast

Domestic

Industrial C-bus

IHC RF controlEIB

Audo Visual

Tyristor dimming

Transistor dimming

Tyristor dimming

Pulse switch Control

Luxmate Instabus

Lighting control; ballast?

DSI DALI1-10V

HF-Ballast

PULSE CONTROL

Lighting control; Analouge 1-10V

N

L

+

-

Switched phase for off

Don´t mix plus and minus

Open control wire = 100% light

Short cut control wire = minimum light level

50-100 ballast on same control line

Dimming quality depends on control

unit performance

Introduced 1990 BY Philips

Open protocol

Lighting control; Analouge 1-10V

N

L

+

-

CONTROL WIRES ARE ONLY

SINGLE ISOLATED FROM MAINS!

Distance between mains and control

wires are less then 8mm and under

4kV.

Control wires must be treated as live!

The same for DSI and DALI

Lighting control; Analogue 1-10V

L N

Sw

itc

he

d p

has

e

PL

US

MIN

US

CONTROL UNIT

•10VDC = max output 100%

•1VDC (or less) = min. output

(depending on the ballast dimming

quality)

10V1V0V

100%

0%

Min.

Lighting control; Analouge 1-10V

10VDC

No voltage drop! All analogue

ballasts are working as parallell

connected power supplies

Voltage drop ”might” occur

between passive controller

and first ballast.

Most likely not.

10VDC

10VDC

10VDC

Lighting control; Analouge 1-10V

10VDC

Ballast with plus and minus shifted

will stay at minimum light level

10VDC

10VDC

10VDC

Lighting control; Analouge 1-10V

2mA

Maximum current per ballast is 2mA.

Today is 0,5mA more common.

2mA

2mA

2mA8mA

All control units made for ballast control can

operate 100mA (equal to 50 ballasts)

Audio Vision systems needs a amplifier to

interface the high current.

AV output works normally with only 5-10mA

Lighting control; Analogue 1-10V

•Open control wire will give 100% light

output.

•Short circuit of the control wire will set

light level to minimum.

•Minimum level is a function internally of

the ballast and will differ between

manyfacturer and lamp type.

Open control line and short circuit

Lighting control; Analogue 1-10V

•A resistor can be used to set a low fixed

output level. A 50k potentiometer can be

used for a simple adjustable setting.

•The value of the resistor will change with

the amount of ballasts.

•All control units made for ballast dimming

are voltage controller, not resistor based.

50kohm

Resistor control

Lighting control; Analogue 1-10V

•Open control wire will give 100% light

output.

•Short circuit of the control wire will set

light level to minimum.

•This can be a useful function in a corridor

if a movement detector controls the

function.

PIR control of two light output levels

50kohm

Like a special Discovery Space e-Sense?

Lighting control; Analogue 1-10V

L N

Sw

itc

he

d p

has

e

PL

US

MIN

US

Relay function, mains controlled

•Electronic control units normally has an

intelligent way of opening the relay after

light level has been dimmed down to

minimum.

•Manually controlled potentiometer can

turn off the light at any point. A kind of

”memory” level.

NOTE!

Allways check the relay/switch quality!

Specification should define how many ballasts can be

connected to the relay/switch.

L

N

PE

+

-

PE

N

L1

L2

L3

L

N

PE

+

-

2

3

4

6

7

-

+

Plint

2

3

4

6

7

-

+

Plint

Electronic ballast

Helvar

Philips

Osram

Electronic ballast

Helvar

Philips

Osram

Contactor

L

N

PE

+

-

2

3

4

6

7

-

+

Plint

Electronic ballast

Helvar

Philips

Osram

Fitting

Fitting

Fitting

Lighting control; Analogue 1-10V

Relay function, mains controlled

multiple phases

Control signal is

”floating” and is

not sensitive of

phase quality.

A phase can be

turned off and the

change will not

affect the light

level of the

remaining

ballasts.

Lighting control; Analogue 1-10V

L N

Sw

itc

he

d p

has

e

PL

US

MIN

US

CONTROL UNIT

•Simple manual control from one point

•10VDC is supplied by the ballast

•Switch must be made to manouver ballast

inrush current, or an external relay can be

used

•More than 50 ballasts can be controlled

via 1-10V line

•Multiple control always needs a central

unit.

•Input to control unit can be one of many

different protocols.

•Many different ways to manouver;

pushbutton, sliders, IR, etc.

EIB, LON, Luxmate, DALI, RS485,

RS232, etc.

Lighting control; PULSE CONTROL

N

L

Off with Switch command

Phase puls control

15(?) ballast on same circuit

DIGITAL?

Different features from suppliers

Different connections from suppliers!!

Introduced 1995

Open protocol?

Aka

Switch Control

SwitchDim

Touch & Dim

TouchDim

Check it out your self!!!!!

Phase over switch

Short pulse for ON/OFF

Long pulse for dimming

L N

Sw

itc

he

d p

has

e

•Simple manual control from multiple point

•Do not mix ballasts from different

suppliers

•Problem can occur if distance is too long

between ballast-switch

•Problem can occur if switching is made

too fast, ballasts can become out of phase.

•All suppliers has a reset function today

Lighting control; PULSE CONTROL

User can find it difficult to

understand the dimming function

There is no universal icon to

describe the function.

Pulse

switch

Lighting control; PULSE CONTROL

…and out of phase

If the switch is manouvered too fast,

the light sources can be controlled to

different levels.

E

N

L

Lighting control; PULSE CONTROL

E

N

L

Resetting after out of phase

Press and hold the switch for

10 seconds.

Light sources will dim to a

preset level, and the system

is ready to use again.

This can work in different ways depending on the manufacturer!

PE

N

L1

L2

L3

L

N

PE

DA

DA

2

3

4

6

7

DA

DA

Plint

L

N

PE

DA

DA

2

3

4

6

7

DA

DA

Plint

TRIDONIC ECO and One4all

Electronic ballast

Tridonic

Electronic ballast

Tridonic

Fitting

Fitting

CONNECTIONS

PE

N

L1

L2

L3

L

N

PE

DA

DA

2

3

4

6

7

DA

DA

Plint

L

N

PE

DA

DA

2

3

4

6

7

DA

DA

Plint

OSRAM & Philips

Electronic ballast

Electronic ballast

Fitting

Fitting

CONNECTIONS

L

N

PE

+

-

PE

N

L1

L2

L3

L

N

PE

Plint

Plint

L

N

PE

+

-

Plint

Fitting

Fitting

Fitting

HELVAR EL-sc connection

Electronic ballast

Helvar

EL-sc

In this example is

one swtich wired

to Helvar EL-sc

ballasts. Note

that neutral is

used for the pulse

control.

Phase OR neutral

can be used

Electronic ballast

Helvar

EL-sc

Electronic ballast

Helvar

EL-sc

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

CONNECTIONS

L

N

PE

+

-

PE

N

L1

L2

L3

L

N

PE

Plint

Plint

L

N

PE

+

-

Plint

Fitting

Fitting

Fitting

HELVAR EL-si connection

Electronic ballast

Helvar

EL-si

Helvar EL-si

ballasts are using

the ”DIGIDIM”

connectors for

pulse control.

This means that a

fitting needs 5

wire connection.

The voltage over

the switch is only

16VDC, but

single isolated Electronic ballast

Helvar

EL-si

Electronic ballast

Helvar

EL-si

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

CONNECTIONS

Lighting control; DSI (digital serial interface)

N

L

DSI

DSI

Off with DSI command

No plus and minus

Open control wire = stop

Short cut control wire = stop

30 ballast on same control line

Dimming quality is digital - logarithmic

Introduced 1995

Only used by Tridonic

Lighting control; DSI (digital serial interface)

N

L

DSI

DSI

•Standard Manchester code

•8-bit commands

time

+5V

-5V

0V

The digital tranmission is quite slow,

but fast enough to control light.

Example of connection diagram DSI

L N

CONTROL UNIT

•A central unit is always needed.

•Input to control unit can be one of many

different protocols.

•Many different ways to control;

pushbutton, sliders, IR, etc.

Analogue 1-10V, EIB, LON, DALI,

RS485, RS232, etc.

DS

I

Tra

nsm

itte

r

Lighting control; DSI (digital serial interface)

A control unit is

even needed for

two button ”blinds”

control

DALI

09.00 Morgen kaffe

Teori omkring DALI.

10.30 Kaffe

Gennemgang af software digidim

“11.30 Frokost

Hands-on” Praktisk orienteret

undervisning i DALI.

14.30 Kaffe

Lidt omkring e-sense.

16.00 Afslutning

Kurset bliver meget teknisk orienteret!

Allt om DALI

FAGERHULT 2007

Mats Wernberg

Product Manager

Lighting Control

Definition

DALI

DALI Stöds av tillverkare

HF don

Philips

Osram

Helvar

Tridonic

VS

Hüco

Magnatec

Styrsystem

Philips

Osram

Helvar

Tridonic

INSTA

ECS

Eckerle

Hadler

m.fl.

Vad är DALI?

Ett tillägg till existerande norm EN60929 annex E

(HF-don prestanda).

Ett standardprotokoll för reaktorer med senaste

teknologi

En standardmetod för styrning av elektroniska

reaktorer via en digital kontrollsignal

Varför digitalt?

Digitala signaler är inte störkänsliga och stör inte

själva

Digitala signaler kan ge större mängder information

och tvåvägskommunikation

Digitala komponenter blir allt mindre fler

funktioner till mindre utrymme och kostnad

DALI liknar DSI…

N

L

DSI

DSI

•Standard Manchester code

•8-bit commands

time

+5V

-5V

0V

DALI är uppbyggt på två följande

8-bitars kommandon.

Med 1 start och 2 stoppbitar

DSI ”hör” DALI kommandon…

Styrsystem

Utvecklingspotential med DALI

Funktionerna för

användaren förändras

marginellt

StyrenhetDALI

HF don

Det blir enklare att

projektera, installera, och

ändra i en anläggning

Hur man vill kontrollera DALI är fritt!

Olika sätt att kontrollera DALI

Centraliserad styrning:

En centralenhet komunicerar mellan styrfunktioner och

DALI belastningar

Exempelvis Osram, Altenburger, Insta, Nortronic och

Philips

StyrenhetDALI

HF donkontrollenhet

Hur man vill kontrollera DALI är fritt!

Olika sätt att kontrollera DALI

Decentraliserad styrning:

Komunikation sker mellan styrfunktioner och DALI-

belastningar endast på DALI

Exempelvis Helvar, Tridonic och Philips

DALIHF don

kontrollenhet

DALI standarden föreskriver ljusnivåer så att de överensstämmer

med den logaritmiska reglerkurva som det mänskliga ögat ser som

en linjär ljusförändring.

Alla DALI reaktorer använder samma logaritmiska kurva oavsett

deras absoluta mininivå.

Fördelar

100%

0%

1%

NP

DALI protocolCable

• Analog kontroll och tänd/släck

Control unit

1-10V

• Digital till från

– Släckning via styrsignal

Fördelar

100101001110 100101001110

• Backchannelling (tvåvägskommunikation)

– Reaktorstatus (on/off)

– Lampeffekt (%)

– Reaktor status (fel/ standby)

Fördelar

• Polaritetsfri kontrollsignal

– Minskar möjlighet till installationsfel

Fördelar

Matning

230V

Befintlig installation

Matning

230V

1-10V

StyrenhetInput

1-10V

StyrenhetInput

Matning

230V

Lösning med traditionell teknik

Matning

230VDALI

StyrenhetInput

Matning

230V

Lösning med DALI

Matning

230VDALI

StyrenhetInput

Lösning med DALI

Nyinstallation

1...10V DALI

Potentialfri styrning (3-fas

installation)

Potentialfri styrning (3-fas

installation)

Reglerområde 1...100% Reglerområde 1...100%,

logaritmisk kurva

Ingen

tvåvägskommunikation

Individuell status rapportering

Ej adresserbar Adresserbart individuellt, i

grupp, och alla (broadcast)

Minne för ljusscener

Programerbar reglertid

Kontrollkabel 2 ledare,

polatitetsbestämd

Kontrollkabel 2 ledare,

polaritetsfri

1-10V jämfört med DALI

• Integrerad till/frånTänd/släck med strömbrytare

Kostnader

Funktioner

Ljuskontroll: kostnader mot funktion

Jämförelse mellan olika system

1..

.10

V

oc

h D

SI

Styrsystem

för hela

fastigheten

Våningsplan

eller delar

av hus

Enskillda rum

Fastighetsstyrning t.ex. EIB eller LON med

kontroll av värme & ventilation, jalusier och

markiser samt övervakningssystem och

belysning

Mindre system som agerar liknande ett

buss-system, men utan alla

samverkande funktioner

Digital eller 1-10 V kontroll

enheter

Pris &

kom

ple

xitet

DA

LI

EIB

ell

er

LO

N

DALI och styrsystemet

1. DALI-protokollet definierar HF-donets gränssnitt

1. Ingen gemensam standard för

styrkomponenter !

1. HF-don av olika fabrikat kan användas, men

styrkomponenter av olika fabrikat BÖR inte blandas

Kontrollfunktioner i DALI

Address 1

1 2 3 ...

... ... 63 64

1 2 3 ...

... ... 15 16

1 2 3 ...

... ... 15 16

1

Group 1

Address 2 Group 2

Address ... Group ...

Address 63 Group 2

Address 64 Group 16

64 individuella

adresser (HF-

don)

Individuella adresser

Address 1

1 2 3 ...

... ... 63 64

1 2 3 ...

... ... 15 16

1 2 3 ...

... ... 15 16

1

Group 1

Address 2 Group 2

Address ... Group ...

Address 63 Group 2

Address 64 Group 16

64 individuella

adresser (HF-

don)

Individuella adresser

Address 1

1 2 3 ...

... ... 63 64

1 2 3 ...

... ... 15 16

1 2 3 ...

... ... 15 16

2

Group 1

Address 2 Group 2

Address ... Group ...

Address 63 Group 2

Address 64 Group 16

16 grupp-

adresser

Gruppering

Address 1

1 2 3 ...

... ... 63 64

1 2 3 ...

... ... 15 16

1 2 3 ...

... ... 15 16

2

Group 1

Address 2 Group 2

Address ... Group ...

Address 63 Group 2

Address 64 Group 16

16 grupp-

adresser

Gruppering

Address 1

1 2 3 ...

... ... 63 64

1 2 3 ...

... ... 15 16

1 2 3 ...

... ... 15 1615

Group 1

Address 2 Group 2

Address ... Group ...

Address 63 Group 2

Address 64 Group 16

15

15

15

15

15

16 ljusscener

(lagras i HF-donen)

Individuellt lagrade ljusscener

INSTALLATIONSEXEMPEL

Gruppering i kontorsplan

Praktiska hållpunkter för

installationer

Praktiska hållpunkter för

installationer

Maximal längd installationskabel:

300m eller ett maximalt spänningsfall på 2V

Enligt AG DALI har praktiska fall visat på följande:

Längd Kabeldiameter

Upp till 100m 0.5 mm2

100-150m 0.75mm2

150-300m 1.5mm2

DALI Basics

Praktiska hållpunkter för installationer

Inget krav på installations ordning

DALI kan installaleras i seriell slinga, stjärnnät eller i

kombinationer därav

DALI Basics

Praktiska hållpunkter för installationer

DALI är galvaniskt skilt från ansluten fas -olika faser kan anslutas till olika belastningar

Ingen slutterminering med motstånd-Jmf med bussystem, där ett eller flera motstånd skall

anslutas för balansering av systemet.

DALI Basics

Praktiska hållpunkter för installationer

DALI och 230V i samma kabel -Den långsamma överföringshastigheten och

enkelisoleringen gör att DALI med fördel kan förläggas i

samma kabel som nätspänning t.ex. till en armatur.

DALI Basics

Praktiska hållpunkter för installationer

DALI Strömförsörjning Max 250mA kan försörja ett DALI system

Det kan användas till 2mA/belastning eller i större mängd till

olika kontrollkomponenter; paneler, sensorer m.m

2mA 250mA

10mA

• Exakta kommandon – även på långa avstånd

• Tändning, släckning och ljusreglering över DALI-bussen

• Ej polariserad buss - mindre risk för felkoppling

• Bussen kan förläggas i samma rör eller kabel som nätspänningen

• Felmeddelande kan erhållas från de digitala DALI-donen

• HF-don för DALI kan adresseras och kontrolleras individuellt

• HF-don för DALI kan tillhöra max 16 grupper och lagra max 16

ljusscener

DALI - egenskaper i korthet

• Scen- och gruppinformation lagras i HF-donet

• Felmeddelande, status ( on/off, aktuell ljusnivå, defekt ljuskälla...)

• Programmerbara parametrar i HF-donet, som tex ljusregleringshastighet,

och HF-donets reaktion vid brott på DALI-bussen mm

• Ljusregleringsområde beror på det aktuella HF-donet. DALI-protokollet

specificerar ljusregleringsområdet från 0,1 till 100 %

DALI - egenskaper i korthet

PRODUKTER

Närmast ljuskällan,

belastning:HF-don för alla typer av lysrör

Närmast ljuskällan,

belastning:Dimmrar

Universaldimmer

1000VA

Tyristordimmer

16A

Närmast ljuskällan,

belastning:Konverters

Konverter DALI till

DSI eller 1-10V

Konverter DALI till

DSI

Närmast ljuskällan,

belastning:Transformatorer

Exempel på DALI

transformator

För övrig belastning:Reläenhet och motorstyrenhet

Reläenhet 4

reläer

Motorstyrenhet

2 motorer

Påverkande enheter:Paneler och ingångsmoduler

Programmerbar

ingångsenhet med

4 funktioner

Ingångsenhet med

4 funktionerTryckknappspanel

4 scenarier, upp/ner

samt från.

Enheten har även

IR-mottagare

IR sändare

Påverkande enheter:IR-sändare och Multisensor

Multisensor

DALI Easy

T5 tubes

Max. 16 ECG

DALI I

PRAKTIKEN

Säker anslutning

3

EXEMPEL 1

Belastning 1 Belastning 2 Belastning 3

125200

Belastning 4

1

34

2

303

•All belastning regleras gemensamt

•Fyra nivåer på panel 125

•IR-sändare

EXEMPEL 2

Belastning 1 Belastning 2 Belastning 3

125200

Belastning 4

•Anslut datorns programvara

DIGIDIM

•Belastning regleras individuellt

•Fyra ljusscener på panel 125

•Namnge belastningar och paneler

EXEMPEL 3

Belastning 1 Belastning 2 Belastning 3

125200

Belastning 4

121200

•Belastning regleras i två grupper

•Panel 111 potentiometrer i två

grupper

•Fyra ljusscener på panel 125 för alla

belastningar med reglertider

•Namnge grupper, belastningar,

paneler och knappar

EXEMPEL 4

Belastning 1 Belastning 2 Belastning 3

125200

Belastning 4

121200

•Programmera scen 14, 15

•PIR tider

•Manuell till automatisk från

•Last level på belastningar

Vidare övningar:

•Konstantljus

•Ändring av panelfunktioner, delad

panel m.m.

•Låsning av funktioner

•Virtuella enheter

ROUTER SYSTEM

FRÅGOR

?

Kan DALI enheter förlora minnet ?

Nej.

Minnet är s.k. flashminne. All

information är lagrad även om

enheten är bortkopplad från nät

eller DALI system.

Vad händer om DALI kontrollspänning försvinner ?

Basinställningen i alla DALI

belastningar är att reglera ljuset till

100%.

Detta kan senare ändras till andra

ljusnivåer.

Varför kallas DALI inte för ett bussystem ?

Bus system betecknas av högre

överföringshastighet och större

programmeringsmöjlighet.

DALI ansluter till Bus system, och

använder liknade funktioner

anpassade och förenklade för

belysning.

•Hur etablerat är DALI idag ? Installationer ?

En av anledningen till detta

seminare är att informera om DALI

och dess betydelse för framtida

belysningsinstallationer.

•Måste man “starta upp” ett DALI system?

Nej.

Alla enheter är förberedda på att

svara till Broadcast kommandon,

som reglerar alla enheter

gemensamt.

Detta kan användas som ett

funktionstest inför senare

programmering

•Behöver man en dator för att programmera installationen?

Nej.

Vissa basfunktioner och

grupperingar kan göras med

tryckknappar eller fjärkontroller av

olika fabrikat. Detta kan vara lagom

för en mindre installation.

Vid mer detaljerade funktioner är

dator ett bra och lätt verktyg för

konfigurering av ett DALI system

•Är kontrollsystemen en del av DALI standarden?

Nej.

Styrsystem av olika fabrikat har

olika funktioner och uppbyggnad.

Man skall använda ett

kontrollsystem i en DALI

installation, men man kan bland hf-

don avsedda för DALI.

•Kan jag reglera mer än lysrör? Andra ljuskällor?

Ja.

Det finns dimmrar, transformatorer,

reläenheter m.m. för olika

belastningar

•Varför behövs en strömförsörjning?

Alla DALI-anslutna enheter måste

känna av den spänning som

kommunikationen sänds över. En

viss ström används dessutom till

dioder i tryckknappspaneler m.m.