50
Asbestos Survey Report Genesee County Administration Building All Accessible Areas 1101 Beach Street Flint, MI March 21 and 22, 2011 Performed for: Genesee County Buildings and Grounds Department 1101 Beach Street Flint, MI 48502 Sierra Technical Services of Freeland, LLC 2366 Hotchkiss Road Freeland, MI 48623 989.496.2325 Project #: 11-03-09

Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Asbestos Survey Report

Genesee County Administration Building All Accessible Areas

1101 Beach Street Flint, MI

March 21 and 22, 2011

Performed for:

Genesee County Buildings and Grounds Department

1101 Beach Street Flint, MI 48502

Sierra Technical Services of Freeland, LLC 2366 Hotchkiss Road Freeland, MI 48623

989.496.2325

Project #: 11-03-09

Page 2: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Sierra Technical Services of Freeland, LLC

GENESEE COUNTY ADMINISTRATION BUILDING ASBESTOS SURVEY PROJECT SUMMARY

Sierra Technical Services was contracted by Genesee County, Buildings & Grounds Department to conduct a facility survey to determine the presence, amount, and locations of asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan. Field investigation was performed on March 21 and 22, 2011. A final report based on the results of the investigation was compiled. General Report Information: A List of Homogeneous Areas of all suspect building materials was compiled. The materials were grouped into one of three defined types on the list. This list also indicated the number of samples collected for each material, whether the material is asbestos containing or non asbestos containing, and approximate amounts of each material, expressed in square or lineal footage, where applicable. Samples of these suspect materials were collected. The number of samples collected of each suspect Homogeneous Area material was determined as per EPA protocol established in the Asbestos Hazard Emergency Response Act (AHERA), 40 CFR, Part 763, based on the material type and/or material quantity found in the building. Sample collection points were documented on the sample Chain of Custody forms, on finalized bulk sample collection forms, and on separate building schematics for each floor of the building. Sample analysis forms were generated by the laboratory that performed the analysis. The analytical data pages identified each suspect material sample by sample number, homogeneous area number, homogeneous material name, and sample location. Asbestos and non asbestos material content for each sample was indicated, expressed in percentage values for each material component. Brief verbal descriptions of each Homogeneous Area material were then compiled. The materials were grouped on the description sheets as either asbestos containing or non asbestos containing. These brief descriptions were intended to provide further clarification of material location, appearance, etc. Finally, laboratory certification and building inspector certification and State of Michigan accreditation information was included. General Field Observations and Notes: Information gathered prior to conducting the survey was:

• The construction date for the building was ca. 1969. • Cosmetic renovation of some office spaces occurred after 1981. These cosmetic construction

materials, if known to have been installed after 1981, were not included in the survey as suspect asbestos materials, as per the State of Michigan Asbestos Program, which allows elimination of materials installed after 1981.

• A new roof had been installed in the recent past. All original roof materials had been removed as part of the new roof installation.

Page 3: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Sierra Technical Services of Freeland, LLC

GENESEE COUNTY ADMINISTRATION BUILDING ASBESTOS SURVEY PROJECT SUMMARY

Information gathered during field investigation showed: • The two boilers that drove the heating system were in operation. Investigation of boiler

interiors could not be performed. Boiler interior investigation was scheduled for after the conclusion of the heating season. The boiler exterior insulation was found to be fiberglass underneath metal skin. The boiler breeches, gaskets in various locations on both boilers, as well as the hot water storage tank in the boiler room, were insulated with suspect asbestos material.

• Mechanical piping (domestic, steam, condensate, chilled water and roof drain) systems were insulated throughout the facility. Pipe run insulation was checked in numerous locations, and was found to be non-asbestos fiberglass. Pipe fittings on all systems were insulated with suspect asbestos containing mud.

• There was a drop in ceiling present throughout the majority of the facility. Samples were collected of both ceiling tile types found.

• All structural steel where visible above all ceilings on all four occupied floors was coated in spray on fireproofing material. Two different types of fireproofing were found. There was abundant fireproofing overspray on roof decking adjacent to structural steel components. Samples of both types were collected.

• Permanent building walls were covered with plaster. The plaster consisted of two layers. The substrate layer was a cementitious composition scratch coat. The top surface layer was a thin white lime finish coat. Samples of both layers were collected.

• Two patterns of metal clad wall panel partitions were found in the majority of occupied building spaces. The partitions were used to divide office cubicles and office spaces. The partition cores were a foil paper covered gypsum board appearing material. This gypsum board material was sampled in both patterns of partition panels.

• Two patterns of 9x9 floor tiles, and three types of 12x12 floor tiles were observed. Red 9x9 tiles were located in all stairwells. Grey streaked 9x9 floor tiles were visible in halls, mechanical rooms, and some offices on all four occupied floors. Carpeting had been installed in some building spaces as part of cosmetic renovation. There is a high likelihood that the grey 9x9 floor tile still exists beneath carpeted building areas. Newer appearing 12x12 tiles were found on the ground floor, south wing, by the HR training room G51, and on the third floor, in the north wing, west wall bathroom in the office area north of the Auditorium. A different pattern of 12x12 floor tiles were found on the first floor, in the south wing Friend of the Court entry area. Passenger elevators had a different type of 12x12 floor tile. Samples were collected of each type of floor tile.

• Air handling system ducts in mechanical rooms and the penthouse were insulated in canvas cloth covered fiberglass. This material was sampled. Ducts above ceilings were in either bare sheet metal, or insulated with new foil covered fiberglass insulation.

• Suspect cloth expansion gasket material was observed. This material was sampled. • Miscellaneous other suspect building materials were observed (e.g. – vinyl wallpaper, vinyl

baseboards, etc.). Samples of these other materials were collected. • Fire rating labels were noted on doors where a fire break was required. No damaged doors were

noted. Samples of core insulation could not be obtained without damaging one or more doors, so the fire door core insulation was presumed to be asbestos containing.

• Samples of all other suspect materials were collected by Sierra staff while on site on March 21 and 22, 2011.

Page 4: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Project #:

Client:

Contact:

Key: Category:Type:

Administration Building

Steve Moelter

A5667

SIERRA TECHNICAL SERVICESBULK SAMPLE COLLECTION RECORD

Location:

Inspector Name:

11-03-09

Category Type

Genesee County

Mr. Raymond Zanke

Notes Sampling Location

Inspector ID #:

Collection Information

1 S TO CGround level, N wing, bathroom hall, N wall above ceiling tile above men's room entry

Sample ID Field ID/HA #

Collection Date: 3/21/11

Field ID/HA Description: Plaster

2

3

4

5

6

7

8

S = Surfacing Material; T = Thermal Systems Insulation; M = Miscellaneous Material

2A S

S

S TO

TOSecond floor, S wing, stairwell lobby, above ceiling tiles along S wall over drinking fountain

Ground level, S wing, SW store room G49, center of room

BR = Brick/Block; O = Other; P = Panel; PR = Pipe Run; SO = Spray On; TO = Trowel On; W = Wall; PF = Pipe Fitting; T = Tile; S = SuspendedPO = Sample site was physically cut into and observed to not contain asbestos. Sample was recorded, but not collected. C = Sample was collected.

1A

1B

1C

1D

1E

1F

1G

S

S

S

S C

SO C

C

C

TO

TO

TO

TOThird floor, S wing, store room 351 next to stairs, W wall of roomC

C

C

First floor, S wing, stairwell lobby, above ceiling tiles over drinking fountain

Collection Date: 3/21/11

Field ID/HA Description: Plaster

Collection Date: 3/21/11

Ground level, N wing, E side N/S hall, W wall above ceiling tile at 1st column N of S doors

Ground level, N wing, W side N/S hall, E wall above ceiling tile at 1st column s of G25 NW entry

Third floor, Auditorium, at outside corner of wall jst S of main entry

Collection Date: 3/21/11

Field ID/HA Description: Plaster

Field ID/HA Description: Plaster

A = Adhesive; B = Boiler/Tank; C = Ceiling; DW = Duct Work; D = Debris; E = Electrical; F = Flooring; G = Glue On; BI = Blown In;

Collection Date: 3/21/11

Field ID/HA Description: Plaster

Collection Date: 3/21/11

Field ID/HA Description: Spray On Fireproofing - Crunchy

Rev. STS/BC - 5/08 Notes:

Field ID/HA Description: Plaster

Collection Date: 3/21/11

Field ID/HA Description: Plaster

Collection Date: 3/21/11

Page 5: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Project #:

Client:

Contact:

Key: Category:Type: A = Adhesive; B = Boiler/Tank; C = Ceiling; DW = Duct Work; D = Debris; E = Electrical; F = Flooring; G = Glue On; BI = Blown In;

Collection Date: 3/21/11

Field ID/HA Description: Spray On Fireproofing - Crunchy

Collection Date: 3/21/11

Field ID/HA Description: Spray On Fireproofing - Fluffy

Rev. STS/BC - 5/08 Notes:

Field ID/HA Description: Spray On Fireproofing - Crunchy

Collection Date: 3/21/11

Field ID/HA Description: Spray On Fireproofing - Fluffy

Collection Date: 3/21/11

Second floor, N wing mechanical room 258, E half area

Collection Date: 3/21/11

Field ID/HA Description: Spray On Fireproofing - Crunchy

Collection Date: 3/21/11

Third floor, N wing mechanical room 346, E wall at angle iron at top of block wall

Third floor, Auditorium, above NW corner ceiling access panel

First floor, S wing, stairwell lobby above ceiling tiles, just E of S wall drinking fountain

Collection Date: 3/21/11

Field ID/HA Description: Spray On Fireproofing - Crunchy

Field ID/HA Description: Spray On Fireproofing - Crunchy

SO

SOSecond floor, N wing, W side N/S hall, 40' S of N end above ceiling tilesC

C

C

S

S

S C

SO C

C

C

SO

SO

BR = Brick/Block; O = Other; P = Panel; PR = Pipe Run; SO = Spray On; TO = Trowel On; W = Wall; PF = Pipe Fitting; T = Tile; S = SuspendedPO = Sample site was physically cut into and observed to not contain asbestos. Sample was recorded, but not collected. C = Sample was collected.

2B

2C

2D

2E

2F

2G

3A

S

16

S = Surfacing Material; T = Thermal Systems Insulation; M = Miscellaneous Material

3B S

S

S SO

SOGround level, NW area, office G31, above ceiling tile

Ground level, N wing, E side N/S hall, at column by G25 SE door above ceiling tile

10

11

12

13

14

15

Collection Information

9 S SO CGround level, N wing, NE area, E wall by 2nd column S of NE corner, inside inner G22 store room

Sample ID Field ID/HA #

Collection Date: 3/21/11

Field ID/HA Description: Spray On Fireproofing - Crunchy

Category Type

Genesee County

Mr. Raymond Zanke

Notes Sampling Location

Inspector ID #:

Administration Building

Steve Moelter

A5667

SIERRA TECHNICAL SERVICESBULK SAMPLE COLLECTION RECORD

Location:

Inspector Name:

11-03-09

Page 6: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Project #:

Client:

Contact:

Key: Category:Type:

Administration Building

Steve Moelter

A5667

SIERRA TECHNICAL SERVICESBULK SAMPLE COLLECTION RECORD

Location:

Inspector Name:

11-03-09

Category Type

Genesee County

Mr. Raymond Zanke

Notes Sampling Location

Inspector ID #:

Collection Information

17 S SO CThird Floor, N wing, N stair pipe chase, at NW column in chase

Sample ID Field ID/HA #

Collection Date: 3/21/11

Field ID/HA Description: Spray On Fireproofing - Fluffy

18

19

20

21

22

23

24

S = Surfacing Material; T = Thermal Systems Insulation; M = Miscellaneous Material

6A T

T

T B

BBoiler room, above #1 boiler, boiler exhaust 6" above lower metal flange

Ground level, N wing, bathroom pipe chase off of janitor closet, S end fitting

BR = Brick/Block; O = Other; P = Panel; PR = Pipe Run; SO = Spray On; TO = Trowel On; W = Wall; PF = Pipe Fitting; T = Tile; S = SuspendedPO = Sample site was physically cut into and observed to not contain asbestos. Sample was recorded, but not collected. C = Sample was collected.

3C

3D

3E

3F

3G

4A

5A

S

S

S

S C

PF C

C

C

SO

SO

SO

SOGround level, N wing, W side N/S hall, at column by G25 SW door, above ceiling tilesC

C

C

Boiler room, SE area, E face of tank, N edge

Collection Date: 3/21/11

Field ID/HA Description: Spray On Fireproofing - Fluffy

Collection Date: 3/21/11

First floor, S wing, stairwell lobby, S wall just E of drinking fountain, above drop in ceiling

Second floor, S wing above ceiling tiles just N of electrical room at E side of stairwell lobby

Second floor, N wing, n stair pipe chase, at NW column in chase

Collection Date: 3/21/11

Field ID/HA Description: Spray On Fireproofing - Fluffy

Field ID/HA Description: Spray On Fireproofing - Fluffy

A = Adhesive; B = Boiler/Tank; C = Ceiling; DW = Duct Work; D = Debris; E = Electrical; F = Flooring; G = Glue On; BI = Blown In;

Collection Date: 3/21/11

Field ID/HA Description: Spray On Fireproofing - Fluffy

Collection Date: 3/22/11

Field ID/HA Description: Domestic Hot & Cold Water Fitting Mud

Rev. STS/BC - 5/08 Notes:

Field ID/HA Description: Hot Water Tank Insulation

Collection Date: 3/22/11

Field ID/HA Description: Boiler Breech Insulation

Collection Date: 3/22/11

Page 7: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Project #:

Client:

Contact:

Key: Category:Type:

Administration Building

Steve Moelter

A5667

SIERRA TECHNICAL SERVICESBULK SAMPLE COLLECTION RECORD

Location:

Inspector Name:

11-03-09

Category Type

Genesee County

Mr. Raymond Zanke

Notes Sampling Location

Inspector ID #:

Collection Information

25 T PF CGround level, S wing, elevator room G46, SW corner, overhead fitting

Sample ID Field ID/HA #

Collection Date: 3/22/11

Field ID/HA Description: Domestic Hot & Cold Water Fitting Mud

26

27

28

29

30

31

32

S = Surfacing Material; T = Thermal Systems Insulation; M = Miscellaneous Material

8C T

T

T PF

PFPenthouse, N wing, damaged fitting of N side of Auditorium AHU

Boiler room, NE area, large fitting on overhead main

BR = Brick/Block; O = Other; P = Panel; PR = Pipe Run; SO = Spray On; TO = Trowel On; W = Wall; PF = Pipe Fitting; T = Tile; S = SuspendedPO = Sample site was physically cut into and observed to not contain asbestos. Sample was recorded, but not collected. C = Sample was collected.

6B

6C

7A

7B

7C

8A

8B

T

T

T

T C

PF C

C

C

PF

PF

PF

PFBoiler room, SW area, fitting by small heat exchanger

C

C

C

Ground floor, N wing mechanical room, damaged fitting next to AHU along S wall

Collection Date: 3/22/11

Field ID/HA Description: Steam Supply/Condensate Fitting Mud

Collection Date: 3/22/11

Third floor, S wing, store room 351, NW corner overhead fitting

First floor, N wing mechanical room, SW corner, condensate fitting

Second floor, N wing mechanical room, overhead steam fitting, SW corner of room

Collection Date: 3/22/11

Field ID/HA Description: Domestic Hot & Cold Water Fitting Mud

Field ID/HA Description: Steam Supply/Condensate Fitting Mud

A = Adhesive; B = Boiler/Tank; C = Ceiling; DW = Duct Work; D = Debris; E = Electrical; F = Flooring; G = Glue On; BI = Blown In;

Collection Date: 3/22/11

Field ID/HA Description: Steam Supply/Condensate Fitting Mud

Collection Date: 3/22/11

Field ID/HA Description: Chilled Water Fitting Mud

Rev. STS/BC - 5/08 Notes:

Field ID/HA Description: Chilled Water Fitting Mud

Collection Date: 3/22/11

Field ID/HA Description: Chilled Water Fitting Mud

Collection Date: 3/22/11

Page 8: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Project #:

Client:

Contact:

Key: Category:Type:

Administration Building

Steve Moelter

A5667

SIERRA TECHNICAL SERVICESBULK SAMPLE COLLECTION RECORD

Location:

Inspector Name:

11-03-09

Category Type

Genesee County

Mr. Raymond Zanke

Notes Sampling Location

Inspector ID #:

Collection Information

33 T PF CPenthouse, SE room, waist level fitting along center of S mezzanine wall

Sample ID Field ID/HA #

Collection Date: 3/22/11

Field ID/HA Description: Roof Drain Fitting Mud

34

35

36

37

38

39

40

S = Surfacing Material; T = Thermal Systems Insulation; M = Miscellaneous Material

10E T

T

T DW

DWThird floor, N wing mechanical room 346, N wing AHU duct, overhead, center of room

Penthouse, SE room, S (B) wing AHU, W end of duct, N edge of duct

BR = Brick/Block; O = Other; P = Panel; PR = Pipe Run; SO = Spray On; TO = Trowel On; W = Wall; PF = Pipe Fitting; T = Tile; S = SuspendedPO = Sample site was physically cut into and observed to not contain asbestos. Sample was recorded, but not collected. C = Sample was collected.

9A

9B

9C

10A

10B

10C

10D

T

T

T

T C

DW C

C

C

PF

PF

DW

DWGround level, N wing mechanical room, N wall, ground floor AHU ductC

C

C

First floor, N wing mechanical room, N wing AHU duct, overhead, center of room

Collection Date: 3/22/11

Field ID/HA Description: Roof Drain Fitting Mud

Collection Date: 3/22/11

Penthouse, SE room, E wall, hanger fitting on riser next to door

Penthouse, N end, E side N/S catwalk, northmost line, S fitting on line

Ground level, N wing mechanical room, W wall, ground floor AHU duct

Collection Date: 3/22/11

Field ID/HA Description: Roof Drain Fitting Mud

Field ID/HA Description: HVAC Duct Insulation

A = Adhesive; B = Boiler/Tank; C = Ceiling; DW = Duct Work; D = Debris; E = Electrical; F = Flooring; G = Glue On; BI = Blown In;

Collection Date: 3/22/11

Field ID/HA Description: HVAC Duct Insulation

Collection Date: 3/22/11

Field ID/HA Description: HVAC Duct Insulation

Rev. STS/BC - 5/08 Notes:

Field ID/HA Description: HVAC Duct Insulation

Collection Date: 3/22/11

Field ID/HA Description: HVAC Duct Insulation

Collection Date: 3/22/11

Page 9: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Project #:

Client:

Contact:

Key: Category:Type:

Administration Building

Steve Moelter

A5667

SIERRA TECHNICAL SERVICESBULK SAMPLE COLLECTION RECORD

Location:

Inspector Name:

11-03-09

Category Type

Genesee County

Mr. Raymond Zanke

Notes Sampling Location

Inspector ID #:

Collection Information

41 T DW CPenthouse, SE room, S (B) wing AHU, S edge of duct

Sample ID Field ID/HA #

Collection Date: 3/22/11

Field ID/HA Description: HVAC Duct Insulation

42

43

44

45

46

47

48

S = Surfacing Material; T = Thermal Systems Insulation; M = Miscellaneous Material

17A M

M

M gasket

gasketBoiler room, #2 boiler, N face, gasket behind small plate on boiler N face

Ground level, N wing, mechanical room, gasket on duct along E wall, center of room

BR = Brick/Block; O = Other; P = Panel; PR = Pipe Run; SO = Spray On; TO = Trowel On; W = Wall; PF = Pipe Fitting; T = Tile; S = SuspendedPO = Sample site was physically cut into and observed to not contain asbestos. Sample was recorded, but not collected. C = Sample was collected.

10F

11A

12A

13A

14A

15A

16A

M

M

M

M C

gasket C

C

C

gasket

gasket

gasket

gasketBoiler room, #2 boiler, S burner face, top of W edge on boiler doorC

C

C

Boiler room, #2 boiler, S face, gesket behind small plate at bottom of breech

Collection Date: 3/22/11

Field ID/HA Description: Boiler 1 Breech Plate Gasket

Collection Date: 3/22/11

Boiler room, #1 Boiler, S burner face, top of W edge on boiler door

Boiler room, #1 boiler, S face, gasket behind small plate at bottom of breech

Boiler room, #1 boiler, N face, gasket behind small plate on boiler N face

Collection Date: 3/22/11

Field ID/HA Description: Boiler 1 face (door) gasket

Field ID/HA Description: Boiler 1 Back (N) Plate Gasket

A = Adhesive; B = Boiler/Tank; C = Ceiling; DW = Duct Work; D = Debris; E = Electrical; F = Flooring; G = Glue On; BI = Blown In;

Collection Date: 3/22/11

Field ID/HA Description: Boiler 2 Face (door) Gasket

Collection Date: 3/22/11

Field ID/HA Description: Woven AHU Expansion Gasket

Rev. STS/BC - 5/08 Notes:

Field ID/HA Description: Boiler 2 Breech Plate Gasket

Collection Date: 3/22/11

Field ID/HA Description: Boiler 2 Back (N) Plate Gasket

Collection Date: 3/22/11

Page 10: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Project #:

Client:

Contact:

Key: Category:Type:

Administration Building

Steve Moelter

A5667

SIERRA TECHNICAL SERVICESBULK SAMPLE COLLECTION RECORD

Location:

Inspector Name:

11-03-09

Category Type

Genesee County

Mr. Raymond Zanke

Notes Sampling Location

Inspector ID #:

Collection Information

49 M gasket CPenhouse, N wing, gasket on A Wing AHU make up duct

Sample ID Field ID/HA #

Collection Date: 3/22/11

Field ID/HA Description: Woven AHU Expansion Gasket

50

51

52

53

54

55

56

S = Surfacing Material; T = Thermal Systems Insulation; M = Miscellaneous Material

20A M

M

M C/T/S

C/T/SGround Level, S wing, elevator equipment room G46, above doorway

First Floor, S wing, NW corner of Friend of the Court Lobby/entry area

BR = Brick/Block; O = Other; P = Panel; PR = Pipe Run; SO = Spray On; TO = Trowel On; W = Wall; PF = Pipe Fitting; T = Tile; S = SuspendedPO = Sample site was physically cut into and observed to not contain asbestos. Sample was recorded, but not collected. C = Sample was collected.

17B

18A

18B

18C

18D

18E

19A

M

M

M

M C

F C

C

C

C/T/S

C/T/S

C/T/S

C/T/SThird Floor, N wing, W side N/S hall, 20' of mechanical room 346 doorC

C

C

Third Floor, N wing men's room, above handicap stall entry

Collection Date: 3/22/11

Field ID/HA Description: Common Dotted Drop In Ceiling Tile

Collection Date: 3/22/11

Ground level, N wing, NE corner, inner G22 room

Ground Level, Cafeteria, W wall at 1st Column S of NW corner

Ground Level, N wing, E side N/S hall, approximately 30' N of S end doors, along W wall of hall

Collection Date: 3/22/11

Field ID/HA Description: Common Dotted Drop In Ceiling Tile

Field ID/HA Description: Common Dotted Drop In Ceiling Tile

A = Adhesive; B = Boiler/Tank; C = Ceiling; DW = Duct Work; D = Debris; E = Electrical; F = Flooring; G = Glue On; BI = Blown In;

Collection Date: 3/22/11

Field ID/HA Description: Common Dotted Drop In Ceiling Tile

Collection Date: 3/22/11

Field ID/HA Description: Tan Speckled 12x12 Floor Tile

Rev. STS/BC - 5/08 Notes:

Field ID/HA Description: Common Dotted Drop In Ceiling Tile

Collection Date: 3/22/11

Field ID/HA Description: Fissured Drop In Ceiling Tile

Collection Date: 3/22/11

Page 11: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Project #:

Client:

Contact:

Key: Category:Type:

Administration Building

Steve Moelter

A5667

SIERRA TECHNICAL SERVICESBULK SAMPLE COLLECTION RECORD

Location:

Inspector Name:

11-03-09

Category Type

Genesee County

Mr. Raymond Zanke

Notes Sampling Location

Inspector ID #:

Collection Information

57 M F CGround level, S wing, HR training room G51, S wall exterior, E end of tiles

Sample ID Field ID/HA #

Collection Date: 3/22/11

Field ID/HA Description: Replacement Tan 12x12 Floor Tile

58

59

60

61

62

63

64

S = Surfacing Material; T = Thermal Systems Insulation; M = Miscellaneous Material

26A M

M

M F

FFirst floor, S wing, W stairwell, top step on short rise to second floor

Ground level, N wing, bathroom hall, center of N wall of hall

BR = Brick/Block; O = Other; P = Panel; PR = Pipe Run; SO = Spray On; TO = Trowel On; W = Wall; PF = Pipe Fitting; T = Tile; S = SuspendedPO = Sample site was physically cut into and observed to not contain asbestos. Sample was recorded, but not collected. C = Sample was collected.

21A

22A

23A

23B

24A

24B

25A

M

M

M

M C

F C

C

C

F

F

F

FN wing, S stairwell on penthouse level landing

C

C

C

S wing, W stairwell, ground level, SW corner of landing between GL and First floor

Collection Date: 3/22/11

Field ID/HA Description: Common Grey Streaked 9x9 Floor Tile/Mastic

Collection Date: 3/22/11

W passenger elevator, at entry, grey colored tile

Ground Floor, N wing, mechanical room, loose tile along E wall

First floor, N wing mechanical room, loose tile in center of room

Collection Date: 3/22/11

Field ID/HA Description: Elevator 12x12 Floor Tile

Field ID/HA Description: Common Grey Streaked 9x9 Floor Tile/Mastic

A = Adhesive; B = Boiler/Tank; C = Ceiling; DW = Duct Work; D = Debris; E = Electrical; F = Flooring; G = Glue On; BI = Blown In;

Collection Date: 3/22/11

Field ID/HA Description: Stairwell Red 9x9 Floor Tile/Mastic

Collection Date: 3/22/11

Field ID/HA Description: Black Baseboard/Mastic

Rev. STS/BC - 5/08 Notes:

Field ID/HA Description: Stairwell Red 9x9 Floor Tile/Mastic

Collection Date: 3/22/11

Field ID/HA Description: Stairwell Riser Tread Linoleum

Collection Date: 3/22/11

Page 12: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Project #:

Client:

Contact:

Key: Category:Type:

Administration Building

Steve Moelter

A5667

SIERRA TECHNICAL SERVICESBULK SAMPLE COLLECTION RECORD

Location:

Inspector Name:

11-03-09

Category Type

Genesee County

Mr. Raymond Zanke

Notes Sampling Location

Inspector ID #:

Collection Information

65 M W/TO CGround Level, S wing, outside SW corner of HR training room G51, E wall, top of black corner edging

Sample ID Field ID/HA #

Collection Date: 3/22/11

Field ID/HA Description: Drywall/Mud

66

67

68

69

70

71

72

S = Surfacing Material; T = Thermal Systems Insulation; M = Miscellaneous Material

31C M

M

M W/TO

W/TOPenthouse, N wing, E wall, 2nd panel S from N end of wall

Penthouse, N wing, E wall, 14th panel S from N end of wall

BR = Brick/Block; O = Other; P = Panel; PR = Pipe Run; SO = Spray On; TO = Trowel On; W = Wall; PF = Pipe Fitting; T = Tile; S = SuspendedPO = Sample site was physically cut into and observed to not contain asbestos. Sample was recorded, but not collected. C = Sample was collected.

27A

28A

29A

29B

30A

31A

31B

M

M

M

M C

W/TO C

C

C

W

W

W

WGround Level, S wing, SW store room G46, stored panel along S wall of roomC

C

C

Penthouse, N wing, E wall, 3rd panel N from S end of wall

Collection Date: 3/22/11

Field ID/HA Description: Metal Panel Partition Core

Collection Date: 3/22/11

Ground Level, N wing, bathroom hall, center of N wall in hall, floor level

Ground Level, N wing, NW office G31, E wall, top of panel S of doorway

Ground Level, S wing, SW store room G46, stored panel in SW corner of room

Collection Date: 3/22/11

Field ID/HA Description: Vinyl Wallpaper

Field ID/HA Description: Metal Panel Partition Core

A = Adhesive; B = Boiler/Tank; C = Ceiling; DW = Duct Work; D = Debris; E = Electrical; F = Flooring; G = Glue On; BI = Blown In;

Collection Date: 3/22/11

Field ID/HA Description: Wood Veneer Panel Partition Core

Collection Date: 3/22/11

Field ID/HA Description: Penthouse Pre-formed Wall Panel

Rev. STS/BC - 5/08 Notes:

Field ID/HA Description: Penthouse Pre-formed Wall Panel

Collection Date: 3/22/11

Field ID/HA Description: Penthouse Pre-formed Wall Panel

Collection Date: 3/22/11

Page 13: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Project #:

Client:

Contact:

Key: Category:Type:

Administration Building

Steve Moelter

A5667

SIERRA TECHNICAL SERVICESBULK SAMPLE COLLECTION RECORD

Location:

Inspector Name:

11-03-09

Category Type

Genesee County

Mr. Raymond Zanke

Notes Sampling Location

Inspector ID #:

Collection Information

73 M A CRoof level, outside of penthouse SE room, E wall, caulk on pebbled panel E of roof exit door

Sample ID Field ID/HA #

Collection Date: 3/22/11

Field ID/HA Description: Penthouse Exterior Wall Caulk

74

S = Surfacing Material; T = Thermal Systems Insulation; M = Miscellaneous Material

BR = Brick/Block; O = Other; P = Panel; PR = Pipe Run; SO = Spray On; TO = Trowel On; W = Wall; PF = Pipe Fitting; T = Tile; S = SuspendedPO = Sample site was physically cut into and observed to not contain asbestos. Sample was recorded, but not collected. C = Sample was collected.

32A

32B M CA

Collection Date:

Field ID/HA Description:

Collection Date:

Roof level, outside of penthouse, NE inside corner where N & SE wings meet

Collection Date: 3/22/11

Field ID/HA Description: Penthouse Exterior Wall Caulk

Field ID/HA Description:

A = Adhesive; B = Boiler/Tank; C = Ceiling; DW = Duct Work; D = Debris; E = Electrical; F = Flooring; G = Glue On; BI = Blown In;

Collection Date:

Field ID/HA Description:

Collection Date:

Field ID/HA Description:

Rev. STS/BC - 5/08 Notes:

Field ID/HA Description:

Collection Date:

Field ID/HA Description:

Collection Date:

Page 14: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Sierra Technical Services of Freeland. LLC HOMOGENEOUS AREA LIST

TYPE: T = thermal systems insulation; S = surfacing material; M = miscellaneous material Asbestos Containing Material (ACM): Y = yes; A = Assumed; N = no; N* = trace (<1%)

Project #: 11-03-09 Inspector ID/Accreditation #: Steve Moelter/A5667 Building: Genesee County Administration Building, 1101 Beach, Flint, MI Date: 3/21/11 Area # Material Description Category # Smpls ACM Amount

SURFACING MATERIAL 1 Plaster S 7 N NA (>5,000 SF)

2 Spray On Fireproofing-Crunchy S 7 Y 165,300 SF 3 Spray On Fireproofing-Fluffy S 7 Y 10,000 SF

THERMAL SYSTEMS INSULATION 4 Hot Water Tank Insulation T 1 Y 107 SF 5 Boiler Breech Insulation T 1 Y 236 SF 6 Domestic Hot & Cold Water Fitting Mud T 3 Y Unknown 7 Steam/Condensate System Fitting Mud T 3 Y Unknown 8 Chilled Water Fitting Mud (Original) T 3 Y Unknown 9 Roof Drain Fitting Mud T 3 Y Unknown 10 HVAC Duct Insulation T 6 N NA

MISCELLANEOUS MATERIAL 11 Boiler 1 Face (Door) Gaskets M 1 N NA 12 Boiler 1 breech plate gasket M 1 Y 3 ft 13 Boiler 1 back (N) plate gasket M 1 Y 3 ft 14 Boiler 2 Face (Door) Gaskets M 1 N NA 15 Boiler 2 breech plate gasket M 1 Y 3 ft 16 Boiler 2 back (N) plate gasket M 1 Y 3 ft 17 Woven AHU expansion gaskets M 2 N NA 18 Common Dotted Drop In Ceiling Tile M 5 N NA 19 Fissured Drop In Ceiling Tile M 1 N NA 20 Tan Speckled 12x12 Floor Tile (FOC area) M 1 N NA 21 Replacement Tan 12x12 Floor Tile (HR hall) M 1 N NA 22 Elevator 12x12 Floor Tile M 1 N NA 23 Common Grey Streaked 9x9 Floor Tile/Mastic M 2 Y/N^ ~74,000SF 24 Stairwell Red 9x9 Floor Tile/Mastic M 2 Y/N^ 1,600 SF 25 Stairwell Riser Tread Linoleum M 1 Y 1,600 SF 26 Black Baseboard/Mastic M 1 N/N^ NA 27 Drywall/Mud (HR area walls) M 1 N NA 28 Vinyl Wallpaper M 1 N NA 29 Metal Panel Partition Core Material M 2 Y Unknown 30 Wood Veneer Panel Partition Core Material M 1 N NA 31 Penthouse Pre-formed Wall Panels M 3 N NA 32 Penthouse Exterior Wall Caulk M 2 N NA 33 Fire Rated Doors M 0 A Unknown ^Two results are listed; the first result is of the material itself (floor tile or baseboard) and the second result is for the mastic or adhesive.

Page 15: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Sierra Technical Services of Freeland, LLC 2366 Hotchkiss Road · Freeland, MI 48623 Working Towards A Cleaner Environment Office/FAX 989.496.2325

Project Management IAQ/Mold Investigation & Testing Facility Surveys Project Design Personnel Training

Mr. Ray Zanke, Supervisor March 30, 2011 Genesee County, Buildings & Grounds Department 1101 Beach Street Flint, MI 48502 [email protected] RE: Administration Building asbestos survey report Dear Mr. Zanke, Enclosed with this letter, please find the asbestos survey report generated for the Genesee County Administration Building, 1101 Beach Street, Flint, Michigan, project # 11-03-09. Field investigation was performed on March 21 and 22, 2011. The following information is contained in this report:

• Cover Letter • Survey Summary • List of Homogeneous Areas • Bulk Sample Collection Forms • Laboratory Analytical Results • Sample Collection Chain of Custody Forms • Bulk Sample Collection Schematics • Homogeneous Area Material Description Pages • Laboratory Certification • Inspector Certification and Accreditation

Thank you for selecting Sierra Technical Services of Freeland, LLC for your professional asbestos services requirements. Please feel free to contact me any questions or if we can be of further service in any way. Sincerely, Stephen M. Moelter, Owner

Page 16: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan
Page 17: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan
Page 18: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Location:

Layer:

Location:

Layer:

Location:

Layer:

NO

Plaster 11A

1BLab ID #: Other - 100%

Ground Level N Wing Bath Hall N WallMaterial:

Project: Administration Building

1

Report To:

1of

Sierra Technical Services of Freeland

ARI Report # Date Collected: Date Received:

Date Reported:

Project # 11-03-09

03/22/11

Lab ID #:

03/21/1103/22/1103/22/11

11-34963Mr. Steve Moelter

2366 Hotchkiss RoadFreeland, MI 48623

Appearance:

Sample Information Asbestos Type/Percent Non-Asbestos

Cust. #:

Date Analyzed:

NOAsbestos Present: 34963 - 03No Asbestos Observed

1of1

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

1

Asbestos Present: Cust. #:

34963 - 02No Asbestos Observed

Other - 100%

Other - 100%No Asbestos Observed

NOAsbestos Present: 34963 - 01

white,nonfibrous,nonhomogenous

Material: Cust. #:

Ground Level N Wing W Side of N/S Hallwhite,nonfibrous,nonhomogenous

Plaster 31C

Appearance:

Lab ID #:

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

1

Plaster 2

white,nonfibrous,nonhomogenousAppearance:

Material: Ground Level N Wing E Side N/S Hall

of

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 1 of 7

Page 19: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Project: Administration Building

Report To:

Sierra Technical Services of Freeland

ARI Report # Date Collected: Date Received:

Date Reported:

Project # 11-03-09

03/22/11

03/21/1103/22/1103/22/11

11-34963Mr. Steve Moelter

2366 Hotchkiss RoadFreeland, MI 48623

Date Analyzed:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Other - 100%

1 of 1

Asbestos Present: Other - 100%

white,nonfibrous,nonhomogenous

Plaster 4

34963 - 061F

1

34963 - 04

Asbestos Present: 1E34963 - 05

No Asbestos ObservedNO

Sample Information Asbestos Type/Percent Non-Asbestos

3rd Floor S Wing Store Room 351 by Stairs

Lab ID #:

Material: Cust. #:

Lab ID #: 1D No Asbestos ObservedCust. #:

Appearance:

NO

3rd Floor Aud at Outside Corner of WallMaterial:

Plaster 5

1st Floor S Wing Stairwell Lobby Above CTPlaster 6

No Asbestos Observed

Appearance: white,nonfibrous,nonhomogenous

Lab ID #: Cust. #:

1 of

Asbestos Present: NO Other - 100%

Robert T. Letarte Jr., Laboratory Director

Material:

Appearance: white,nonfibrous,nonhomogenous

For Layered Samples, each component will be analyzed and reported separately.

1 of 1

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 2 of 7

Page 20: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Project: Administration Building

Report To:

Sierra Technical Services of Freeland

ARI Report # Date Collected: Date Received:

Date Reported:

Project # 11-03-09

03/22/11

03/21/1103/22/1103/22/11

11-34963Mr. Steve Moelter

2366 Hotchkiss RoadFreeland, MI 48623

Date Analyzed:

Location:

Layer:

Location:

Layer:

Location:

Layer:

2ACust. #:

Other - 95%Lab ID #: 34963 - 09 Asbestos Present: YESChrysotile - 5%

Material: Cust. #: 2B

Spray on Fireproofing- C2

1white,fibrous,homogenous

Ground Level N Wing NE Area E Wall

Robert T. Letarte Jr., Laboratory Director

Appearance:

For Layered Samples, each component will be analyzed and reported separately.

1 of

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

Appearance: white,nonfibrous,nonhomogenous

Cust. #: 1G

Sample Information Asbestos Type/Percent Non-Asbestos

Material: Plaster 7

NOLab ID #: 34963 - 07 Asbestos Present: No Asbestos Observed

Other - 100%

2nd Floor S Wing Stairwell Lobby

Lab ID #:

1 of 1

34963 - 08

Material: Spray on Fireproofing- Crunchy 1

Asbestos Present: YES Other - 95%Chrysotile - 5%

Ground Level S Wing SW Store Room G49Appearance: white,fibrous,homogenous

1 of 1

NVLAP Lab Code 102118-0

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 3 of 7

Page 21: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Project: Administration Building

Report To:

Sierra Technical Services of Freeland

ARI Report # Date Collected: Date Received:

Date Reported:

Project # 11-03-09

03/22/11

03/21/1103/22/1103/22/11

11-34963Mr. Steve Moelter

2366 Hotchkiss RoadFreeland, MI 48623

Date Analyzed:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Lab ID #: Other - 95%YES34963 - 10

1 of

Material:

Other - 96%Lab ID #: Cust. #: 2D

1

YES

34963 - 12

Asbestos Present: Chrysotile - 4%

Asbestos Present:

34963 - 11

Appearance: white,fibrous,homogenous

Cust. #: 2C

Sample Information Asbestos Type/Percent Non-Asbestos

Asbestos Present:

Spray on Fireproofing- C3

1

3rd Floor N Wing Mech Room 34C E Wall

Chrysotile - 5%

Material: Spray on Fireproofing- C4

Appearance: white,fibrous,homogenous3rd Floor Aud Above NW Corner Ceiling

1

Material: Spray on Fireproofing- C5Cust. #:

of

YES Other - 95%Lab ID #:

Appearance: white,fibrous,homogenous

2E Chrysotile - 5%

1st Floor S Wing Stairwell Lobby Above CT

For Layered Samples, each component will be analyzed and reported separately.

1 of 1

NVLAP Lab Code 102118-0

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 4 of 7

Page 22: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Project: Administration Building

Report To:

Sierra Technical Services of Freeland

ARI Report # Date Collected: Date Received:

Date Reported:

Project # 11-03-09

03/22/11

03/21/1103/22/1103/22/11

11-34963Mr. Steve Moelter

2366 Hotchkiss RoadFreeland, MI 48623

Date Analyzed:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Appearance: 2nd Floor N Wing Mech Room 258

Chrysotile - 5%

Fiberglass - 60%

Material:

YESLab ID #: 34963 - 15 Asbestos Present:

of 1

Appearance: white,fibrous,homogenous2nd Floor N Wing W Side N/S Hall

2G

1 of

Cust. #:

Material: 2FCust. #:

Lab ID #: Asbestos Present: Other - 95%

34963 - 13 Other - 95%Lab ID #: Asbestos Present:

Sample Information Asbestos Type/Percent Non-Asbestos

YESChrysotile - 5%

Spray on Fireproofing- Crunchy 6

Other - 25%Material: Spray on Fireproofing- Fluffy 1Cust. #: 3A Amosite - 15%

1

34963 - 14 YES

1

Spray on Fireproofing- C7

white,fibrous,homogenous

NVLAP Lab Code 102118-0

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

For Layered Samples, each component will be analyzed and reported separately.

1

Ground Level NW Area Office G31Appearance: grey,fibrous,homogenous

1 of

Robert T. Letarte Jr., Laboratory Director

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 5 of 7

Page 23: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Project: Administration Building

Report To:

Sierra Technical Services of Freeland

ARI Report # Date Collected: Date Received:

Date Reported:

Project # 11-03-09

03/22/11

03/21/1103/22/1103/22/11

11-34963Mr. Steve Moelter

2366 Hotchkiss RoadFreeland, MI 48623

Date Analyzed:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

Robert T. Letarte Jr., Laboratory Director

For Layered Samples, each component will be analyzed and reported separately.

1

Material: Spray on Fireproofing- F4

ofAppearance:

Cellulose - 50%

1st Floor S Wing Stairwell Lobby S Wall

1grey,fibrous,homogenous

Other - 35%

of 1

Asbestos Present: Amosite - 15%

YESLab ID #: 34963 - 18Cust. #: 3D

Other - 40%

1

Material: Spray on Fireproofing- F3

YES

Appearance:

Cust. #: 3C Amosite - 10%

grey,fibrous,homogenous

Asbestos Present:

3rd Floor N Wing N Stair Pipe Chase

Fiberglass - 50%

1 of 1

Lab ID #: 34963 - 17

Ground Level N Wing E Side N/S HallAppearance: grey,fibrous,homogenous

Cust. #: 3B Amosite - 10%YESLab ID #: 34963 - 16 Asbestos Present:

Other - 30%

Sample Information Asbestos Type/Percent Non-Asbestos

Fiberglass - 60%

Material: Spray on Fireproofing- F2

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 6 of 7

Page 24: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Project: Administration Building

Report To:

Sierra Technical Services of Freeland

ARI Report # Date Collected: Date Received:

Date Reported:

Project # 11-03-09

03/22/11

03/21/1103/22/1103/22/11

11-34963Mr. Steve Moelter

2366 Hotchkiss RoadFreeland, MI 48623

Date Analyzed:

Location:

Layer:

Location:

Layer:

Location:

Layer:

For Layered Samples, each component will be analyzed and reported separately.

1

Robert T. Letarte Jr., Laboratory Director

of 1

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

NVLAP Lab Code 102118-0

Fiberglass - 60%Other - 30%

Lab ID #:

Appearance: grey,fibrous,homogenous

YES

Appearance:

Asbestos Present: Cust. #: 3G Amosite - 10%

Ground Level N Wing W Side of N/S HallMaterial: Spray on Fireproofing- F7

2nd Floor N Wing N Stair Pipe Chase

34963 - 21

of 11

Material: Spray on Fireproofing- F6

grey,fibrous,homogenous

YES Fiberglass - 50%Cust. #: 3F Amosite - 15% Other - 35%Lab ID #: 34963 - 20 Asbestos Present:

1 of 1Appearance: grey,fibrous,homogenous

2nd Floor S Wing Above Ceiling Joist Material: Spray on Fireproofing- F5

Other - 35%

Sample Information Asbestos Type/Percent Non-Asbestos

Asbestos Present: YES Fiberglass - 50%Cust. #: Lab ID #: 34963 - 19

3E Amosite - 15%

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 7 of 7

Page 25: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan
Page 26: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan
Page 27: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan
Page 28: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan
Page 29: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan
Page 30: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Location:

Layer:

Location:

Layer:

Location:

Layer:

For Layered Samples, each component will be analyzed and reported separately.

of 1

Ground Level N Wing Bath Pipe Chase

Material: HW Tank

Asbestos Present: YES

Material: Cust. #:

YES Fiberglass - 30%Other - 62%

of

1

Domestic Hot & Cold Fitting Mud 16A

Boiler #1.Breech 6" Above Lower Flange

grey,fibrous,homogenous

Material:

1

34985 - 01Chrysotile - 50%

YESAsbestos Present:

Boiler Breech

34985 - 03

NVLAP Lab Code 102118-0

Robert T. Letarte Jr., Laboratory Director

Lab ID #: Cust. #:

34985 - 02

Freeland, MI 48623

Appearance:

Sample Information Asbestos Type/Percent Non-Asbestos

Cust. #: Other - 50%

Project # 11-03-09

03/24/11

Lab ID #:

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter

Appearance:

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

Date Collected: Date Received: Date Analyzed:2366 Hotchkiss

5AFiberglass - 10%Other - 80%

Project: Admin. Bldg.

1

Report To:

1of

Sierra Technical Services of Freeland

ARI Report #

Appearance: white,fibrous,homogenous1

Asbestos Present: Lab ID #:

white,fibrous,homogenous

Date Reported:

Boiler Room SE Area E Face of Tank, N

Chrysotile - 10%

Chrysotile - 8%

4A

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 1 of 21

Page 31: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

Material: Steam Supply/Cond Fitting Mud 1

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

1 of 1Appearance: grey,fibrous,homogenous

1

1st Floor N Wing Mech Room SW Corner

34985 - 06

3rd Floor S Wing Store Room 351Appearance: white,fibrous,homogenous

Fiberglass - 30%Lab ID #: Cust. #: Other - 60%

34985 - 05

Material: Domestic Hot & Cold Fitting Mud 36C

Asbestos Present: YES

white,fibrous,homogenous

Fiberglass - 40%Asbestos Present: YES

of 1

Lab ID #: 6B Chrysotile - 9%34985 - 04 Asbestos Present:

1

Cust. #: Other - 61%

Ground Level S Wing Elev Room G46Appearance:

Material: Domestic Hot & Cold Fitting Mud 2

Cust. #: Other - 54%Chrysotile - 6%

Fiberglass - 30%

Sample Information Asbestos Type/Percent Non-Asbestos

YES

Chrysotile - 10%

1 of

7ALab ID #:

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 2 of 21

Page 32: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

For Layered Samples, each component will be analyzed and reported separately.

1 of

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

1

Ground Floor N Wing Mech RoomAppearance: grey,fibrous,homogenous

2 of 2

Boiler Rm SW Area by Small Heat ExchAppearance: grey,fibrous,homogenous

Asbestos Present: YES Fiberglass - 40%Other - 52%Chrysotile - 8%

Material: Steam Supply Cond. Fitting Mud 3

1 of 1

2nd Floor N Wing Mech Room OverheadAppearance: grey,fibrous,homogenous

Fiberglass - 40%Cust. #: 7B Other - 54%Chrysotile - 6%Lab ID #:

Material: Steam Supply Cond Fitting Mud 2

Sample Information Asbestos Type/Percent Non-Asbestos

Chrysotile - 7%Lab ID #: 34985 - 09Cust. #: 8A Other - 58%Material: Chilled Water Fitting Mud 1

NVLAP Lab Code 102118-0

Asbestos Present: YES Mineral Wool - 35%

Cust. #: 7CLab ID #: 34985 - 08

34985 - 07 Asbestos Present: YES

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 3 of 21

Page 33: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

1

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

Appearance: grey,fibrous,homogenousof 1

Penthouse SE Room Waist Level Fitting

YES Mineral Wool - 40%

Material: Roof Drain Fitting Mud 1Cust. #: 9A Chrysotile - 6% Other - 54%Lab ID #: 34985 - 12 Asbestos Present:

1 of 1

Cust. #: 8C Chrysotile - 10% Other - 60%Material: Chilled Water Fitting Mud 3

Pent. Damaged Fitting N Side of Aud Attic

Boiler Room NE Area LG FittingAppearance: grey,fibrous,homogenous

1 of 1

Cust. #: 8B Chrysotile - 10% Other - 60%Asbestos Present:

Mineral Wool - 30%

Mineral Wool - 30%YES

Asbestos Present: YES

Appearance: grey,fibrous,homogenous

Lab ID #: 34985 - 11

34985 - 10

Material: Chilled Water Fitting Mud 2

Sample Information Asbestos Type/Percent Non-Asbestos

Lab ID #:

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 4 of 21

Page 34: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

of 1Appearance: yellow,fibrous,nonhomogenous

1

Other - 10%Ground Level N Wing Mech Room W Wall

Cust. #: 10A No Asbestos ObservedMaterial: HVAC Duct Insulation 1

Lab ID #: 34985 - 15 Asbestos Present: Fiberglass - 60%

NO Cellulose - 30%

1 of 1

Sample Information Asbestos Type/Percent Non-Asbestos

34985 - 13 Mineral Wool - 50%Lab ID #: Asbestos Present: YES

Mineral Wool - 40%

1 of 1

Material: Chrysotile - 5% Other - 45%

Other - 54%

Appearance: grey,fibrous,homogenousPenthouse SE Room E Wall

YESAsbestos Present: 34985 - 14

Roof Drain Fitting Mud 2Cust. #: 9B

Lab ID #:

Appearance:

Cust. #: 9C

Penthouse N End Catwalk S Fitting

Chrysotile - 6%Material: Roof Drain Fitting Mud 3

NVLAP Lab Code 102118-0

grey,fibrous,homogenous

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 5 of 21

Page 35: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

Lab ID #: 34985 - 16 Asbestos Present: NO Cellulose - 20%

Material: HVAC Duct Insulation 2 Other - 20%Cust. #: 10B No Asbestos Observed Fiberglass - 60%

Ground Level N Wing Mech Room N WallAppearance: yellow,fibrous,nonhomogenous

1 of 1

Lab ID #: 34985 - 17 Asbestos Present: Cust. #: 10C No Asbestos Observed Fiberglass - 10%

1st Floor N Wing Mech Room N (A) Wing

NO Cellulose - 60%

Material: HVAC Duct Insulation 3 Other - 30%

Appearance: white,fibrous,nonhomogenous1 of 1

NO Cellulose - 10%Cust. #: 10D No Asbestos Observed Fiberglass - 80%Lab ID #: 34985 - 18 Asbestos Present:

Material: HVAC Duct Insulation 4 Other - 10%3rd Floor N Wing Mech Room 346

Appearance: white,fibrous,nonhomogenous1 of 1

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 6 of 21

Page 36: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

Other - 10%

NO Cellulose - 10%Cust. #: 10E No Asbestos Observed Fiberglass - 80%Lab ID #: Asbestos Present:

Material: HVAC Duct Insulation 5

34985 - 19

Penthouse SE Room S (B) WingAppearance: white,fibrous,nonhomogenous

1 of 1

Lab ID #: 34985 - 20 Asbestos Present: Cust. #: 10F No Asbestos Observed Fiberglass - 60%

Penthouse SE Room S (B) Wing

NO Cellulose - 15%

Material: HVAC Insulation 6 Other - 25%

Appearance: black,fibrous,nonhomogenous1 of 1

NO Fiberglass - 100%Cust. #: 11A No Asbestos ObservedLab ID #: 34985 - 21 Asbestos Present:

Material: Boiler 1 Face GasketS Burner Face Top of W Ridge on Door

Appearance: white,fibrous,homogenous1 of 1

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 7 of 21

Page 37: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

YES Other - 10%Cust. #: 12A Chrysotile - 90%Lab ID #: Asbestos Present:

Material: Boiler 1 Breech Plate Gasket

34985 - 22

S Face Gasket Behind Small PlateAppearance: white,fibrous,homogenous

1 of 1

Lab ID #: 34985 - 23 Asbestos Present: Cust. #: 13A Chrysotile - 90%

N Face Gasket Behind Small Plate

YES Other - 10%

Material: Boiler 1 Back N Plate Gasket

Appearance: brown,fibrous,homogenous1 of 1

NO Fiberglass - 100%Cust. #: 14A No Asbestos ObservedLab ID #: 34985 - 24 Asbestos Present:

Material: Boiler 2 Face GasketS. Burner Face Top of W Edge on Door

Appearance: white,fibrous,homogenous1 of 1

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 8 of 21

Page 38: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

YES Other - 5%Cust. #: 15A Chrysotile - 95%Lab ID #: Asbestos Present:

Material: Boiler 2 Breech Plate Gasket

34985 - 25

S Face Gasket Behind Small PlateAppearance: white,fibrous,homogenous

1 of 1

Lab ID #: 34985 - 26 Asbestos Present: Cust. #: 16A Chrysotile - 95%

N Face Gasket Behind Small Plate

YES Other - 5%

Material: Boiler 2 Back N Plate Gasket

Appearance: white,fibrous,homogenous1 of 1

NO Cellulose - 90%Cust. #: 17A No Asbestos Observed Other - 10%Lab ID #: 34985 - 27 Asbestos Present:

Material: Woven Attic Gasket 1Ground Level N Wing Mech Room

Appearance: grey,fibrous,homogenous1 of 1

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 9 of 21

Page 39: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

NO Cellulose - 90%Cust. #: 17B No Asbestos Observed Other - 10%Lab ID #: Asbestos Present:

Material: Woven Attic Gasket 2

34985 - 28

Penthouse N Wing Gasket on Attic A WingAppearance: white,fibrous,homogenous

1 of 1

Lab ID #: 34985 - 29 Asbestos Present: Cust. #: 18A No Asbestos Observed Mineral Wool - 20%

Ground Floor N Wing NE Corner G22 Rm Other - 15%

NO Cellulose - 45%

Material: Common Dotted Drop in Ceiling Tile 1 Fiberglass - 20%

Appearance: beige,fibrous,homogenous1 of 1

NO Cellulose - 45%Cust. #: 18B No Asbestos Observed Mineral Wool - 20%Lab ID #: 34985 - 30 Asbestos Present:

Material: Common Dotted Drop in Ceiling Tile 2 Fiberglass - 20%Ground Level Cafeteria W Wall 1st Column Other - 15%

Appearance: beige,fibrous,homogenous1 of 1

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 10 of 21

Page 40: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

Fiberglass - 20%

NO Cellulose - 45%Cust. #: 18C No Asbestos Observed Mineral Wool - 20%Lab ID #: Asbestos Present:

Material: Common Dotted Drop in Ceiling Tile 3

34985 - 31

Ground Level N Wing E Side N/S Hall Other - 15%Appearance: beige,fibrous,homogenous

1 of 1

Lab ID #: 34985 - 32 Asbestos Present: Cust. #: 18D No Asbestos Observed Mineral Wool - 25%

3rd Floor N Wing W Side N/S Hall Other - 15%

NO Cellulose - 40%

Material: Common Dotted Drop in Ceiling Tile 4 Fiberglass - 20%

Appearance: beige,fibrous,homogenous1 of 1

NO Cellulose - 40%Cust. #: 18E No Asbestos Observed Mineral Wool - 20%Lab ID #: 34985 - 33 Asbestos Present:

Material: Common Dotted Drop in Ceiling Tile 5 Fiberglass - 20%3rd Floor N Wing Men's Room Other - 15%

Appearance: beige,fibrous,homogenous1 of 1

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 11 of 21

Page 41: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

NO Fiberglass - 95%Cust. #: 19A No Asbestos Observed Other - 5%Lab ID #: Asbestos Present:

Material: Fissured Drop in Ceiling Tile

34985 - 34

Ground Level S Wing Elev Room G46Appearance: yellow,fibrous,nonhomogenous

1 of 1

Lab ID #: 34985 - 35 Asbestos Present: Cust. #: 20A No Asbestos Observed

1st Floor S Wing NW Corner Lobby Area

NO Other - 100%

Material: 12x12 Tan Floor Tile

Appearance: beige,nonfibrous,homogenous1 of 2

NO Cellulose - 5%Cust. #: 20A No Asbestos Observed Other - 95%Lab ID #: 34985 - 35a Asbestos Present:

Material: Mastic1st Floor S Wing NW Corner Lobby Area

Appearance: yellow,fibrous,homogenous2 of 2

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 12 of 21

Page 42: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

NO Other - 100%Cust. #: 21A No Asbestos ObservedLab ID #: Asbestos Present:

Material: Replacement 12x12 Tan Floor Tile

34985 - 36

Ground Level S Wing HR Training RM G51Appearance: white,nonfibrous,homogenous

1 of 2

Lab ID #: 34985 - 36a Asbestos Present: Cust. #: 21A No Asbestos Observed Other - 95%

Ground Level S Wing HR Training RM G51

NO Cellulose - 5%

Material: Mastic

Appearance: black,fibrous,homogenous2 of 2

NO Other - 100%Cust. #: 22A No Asbestos ObservedLab ID #: 34985 - 37 Asbestos Present:

Material: 12x12 Grey Floor TileW Passenger Elevator at Entry

Appearance: grey,nonfibrous,homogenous1 of 2

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 13 of 21

Page 43: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

NO Cellulose - 5%Cust. #: 22A No Asbestos Observed Other - 95%Lab ID #: Asbestos Present:

Material: Mastic

34985 - 37a

W Passenger Elevator at EntryAppearance: yellow,fibrous,homogenous

2 of 2

Lab ID #: 34985 - 38 Asbestos Present: Cust. #: 23A Chrysotile - 6%

N Wing Mech Room Loose Along E Wall

YES Other - 94%

Material: 9x9 Grey Floor Tile

Appearance: grey,fibrous,homogenous1 of 2

NO Other - 100%Cust. #: 23A No Asbestos ObservedLab ID #: 34985 - 38a Asbestos Present:

Material: MasticN Wing Mech Room Loose Along E Wall

Appearance: black,nonfibrous,homogenous2 of 2

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 14 of 21

Page 44: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

YES Other - 95%Cust. #: 23B Chrysotile - 5%Lab ID #: Asbestos Present:

Material: 9x9 Grey Floor Tile

34985 - 39

1st Floor N Wing Mech Room Loose TileAppearance: grey,fibrous,homogenous

1 of 2

Lab ID #: 34985 - 39a Asbestos Present: Cust. #: 23B No Asbestos Observed

1st Floor N Wing Mech Room Loose Tile

NO Other - 100%

Material: Mastic

Appearance: black,nonfibrous,homogenous2 of 2

YES Other - 93%Cust. #: 24A Chrysotile - 7%Lab ID #: 34985 - 40 Asbestos Present:

Material: 9x9 Red Floor Tile 1N Wing S Stairwell on Penthouse Level

Appearance: red,fibrous,homogenous1 of 2

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 15 of 21

Page 45: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

NO Cellulose - 5%Cust. #: 24A No Asbestos Observed Other - 95%Lab ID #: Asbestos Present:

Material: Mastic

34985 - 40a

N Wing S Stairwell on Penthouse Level Appearance: yellow,fibrous,homogenous

2 of 2

Lab ID #: 34985 - 41 Asbestos Present: Cust. #: 24B Chrysotile - 6%

Ground Level S Wing W Stairwell

YES Other - 94%

Material: 9x9 Red Floor Tile 2

Appearance: red,fibrous,homogenous1 of 2

NO Cellulose - 5%Cust. #: 24B No Asbestos Observed Other - 95%Lab ID #: 34985 - 41a Asbestos Present:

Material: MasticGround Level S Wing W Stairwell

Appearance: yellow,fibrous,homogenous2 of 2

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 16 of 21

Page 46: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

YES Other - 97%Cust. #: 25A Chrysotile - 3%Lab ID #: Asbestos Present:

Material: Riser Tread Linoleum

34985 - 42

1st Floor S Wing W Stairwell Top StepAppearance: red,fibrous,homogenous

1 of 2

Lab ID #: 34985 - 43 Asbestos Present: Cust. #: 26A No Asbestos Observed

Ground Level N Wing Bath Hall

NO Other - 100%

Material: Black Baseboard

Appearance: black,nonfibrous,homogenous1 of 2

NO Cellulose - 3%Cust. #: 26A No Asbestos Observed Other - 97%Lab ID #: 34985 - 43a Asbestos Present:

Material: MasticGround Level N Wing Bath Hall

Appearance: yellow,fibrous,homogenous2 of 2

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 17 of 21

Page 47: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

NO Other - 100%Cust. #: 27A No Asbestos ObservedLab ID #: Asbestos Present:

Material: Mud

34985 - 44

Grnd Level S Wing o/s SW Corner Rm G51Appearance: beige,nonfibrous,homogenous

1 of 1

Lab ID #: 34985 - 45 Asbestos Present: Cust. #: 28A No Asbestos Observed Other - 50%

Ground Level N Wing Bath Hall

NO Cellulose - 50%

Material: Vinyl Wallpaper

Appearance: white,fibrous,homogenous1 of 1

YES Other - 96%Cust. #: 29A Chrysotile - 4%Lab ID #: 34985 - 46 Asbestos Present:

Material: Metal Panel Partition Core 1Ground Level N Wing NW Office G31

Appearance: white,fibrous,homogenous1 of 1

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 18 of 21

Page 48: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

YES Other - 96%Cust. #: 29B Chrysotile - 4%Lab ID #: Asbestos Present:

Material: Metal Panel Partition Core 2

34985 - 47

Ground Level S Wing SW Store Room G46Appearance: white,fibrous,homogenous

1 of 1

Lab ID #: 34985 - 48 Asbestos Present: Cust. #: 30A No Asbestos Observed Other - 98%

Ground Level S Wing SW Store Room G46

NO Cellulose - 2%

Material: Wood Veneer Panel Partition Core

Appearance: white,fibrous,homogenous1 of 1

NO Other - 100%Cust. #: 31A No Asbestos ObservedLab ID #: 34985 - 49 Asbestos Present:

Material: Pre Formed Wall Panel 1Penthouse N Wing E Wall 3rd Panel

Appearance: white,nonfibrous,homogenous1 of 1

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 19 of 21

Page 49: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

NO Other - 100%Cust. #: 31B No Asbestos ObservedLab ID #: Asbestos Present:

Material: Pre Formed Wall Panel 2

34985 - 50

Penthouse N Wing E Wall 2nd PanelAppearance: white,nonfibrous,homogenous

1 of 1

Lab ID #: 34985 - 51 Asbestos Present: Cust. #: 31C No Asbestos Observed

Penthouse N wing E Wall 14th Panel

NO Other - 100%

Material: Pre Formed Wall Panel 3

Appearance: white,nonfibrous,homogenous1 of 1

NO Other - 100%Cust. #: 32A No Asbestos ObservedLab ID #: 34985 - 52 Asbestos Present:

Material: Exterior Wall Caulk 1Penthouse SE Room Caulk on Panel

Appearance: white,nonfibrous,homogenous1 of 1

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 20 of 21

Page 50: Asbestos Survey Report - Genesee County, Michigan...asbestos containing materials throughout the Genesee County Administration Building, located at 1101 Beach Street, Flint, Michigan

Certificate of Laboratory AnalysisTest Method, Polarized Light Microscopy (PLM)

Freeland, MI 48623

Project # 11-03-09

03/24/11

03/22/1103/23/1103/24/11

11-34985Mr. Steve Moelter Date Collected:

Date Received: Date Analyzed:2366 Hotchkiss

Project: Admin. Bldg.

Report To:

Sierra Technical Services of Freeland

ARI Report #

Date Reported:

Location:

Layer:

Location:

Layer:

Location:

Layer:

Sample Information Asbestos Type/Percent Non-Asbestos

NO Other - 100%Cust. #: 32B No Asbestos ObservedLab ID #: Asbestos Present:

Material: Exterior Wall Caulk 2

34985 - 53

Penthouse Exterior NE Inside CornerAppearance: white,nonfibrous,homogenous

1 of 1

Lab ID #: Asbestos Present: Cust. #: Material:

Appearance: of

Cust. #: Lab ID #: Asbestos Present:

Material:

Appearance: of

NVLAP Lab Code 102118-0

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.

APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991

Page 21 of 21