16
Guide for selecting fiber-free, mold-resistant mechanical insulation from the makers of Armaflex ® • The IAQ Insulation • Exclusive EPA-registered antimicrobial • Supports LEED initiatives Armacell Product Selection Guide advanced insulation

Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

  • Upload
    lytu

  • View
    225

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

Guide for selecting fiber-free, mold-resistant mechanical insulation from the makers of Armaflex®

• The IAQ Insulation™

• Exclusive EPA-registered antimicrobial• Supports LEED initiatives

Armacell Product Selection Guide

a d v a n c e d i n s u l a t i o n

Page 2: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

2 | Armacell Product Selector | www.armacell.us

Application REFRIGERATION, HOT & COLD LINES,CHILLED WATER

HVAC INTERIOR & ExTERIOR DUCT SYSTEMS

MECHANICAL SYSTEMS,CHILLERS

MECHANICAL SYSTEMS,CHILLERS

INDUSTRIAL,PHARMACEUTICAL,MARINE & OFFSHORE

SOLAR RESIDENTIALPLUMBING

ProductRequirements

• Energy saving• Code compliant• Thermally efficient• Moisture resistant• Mold resistant• 25/50 rating• Low VOC,

formaldehyde free• Fiber free

• Energy saving• Code compliant• 25/50 rating• Tough, durable• Flexible

• Energy saving• Code compliant• Moisture resistant• Mold resistant• 25/50 rating• Fiber free• Noise blocking• Outdoors:

Maintenance-free, UV-resistant

• Energy saving• Code compliant• Thermally efficient• Moisture resistant• Mold resistant• 25/50 rating• Sheet & roll forms• Easy to cut and

fabricate

• Energy saving• Code compliant• Thermally efficient• Moisture resistant• Mold resistant• 25/50 rating• Sheet & roll forms• Easy to cut and fabricate

• Energy saving• Thermally efficient• Moisture resistant• 25/50 rating• Flexible• Durable, UV-resistant

outdoors

• Energy saving• Code compliant• Thermally efficient• High temperature range

for solar collectors• Mold resistant• Flexible

• Energy saving• Economical• Thermally efficient• Moisture resistant• 25/50 rating• Fiber free• Noise blocking

RecommendedProduct

• AP Armaflex, AP Armaflex SS (Self-Seal)

• Armaflex Coil• AP Armaflex W

• AP Armaflex, AP Armaflex SS

• AC Accoflex• Armaflex Coil

• AP Armaflex Self-Adhering (SA) Duct Liner/Wrap and AP Armaflex SA Sheet

• AP Coilflex

• AP Armaflex• AP Armaflex

Sheet and Rolls

• AP Armaflex• AP Armaflex Sheet

and Rolls

• AP Armaflex• Arma-Chek• NH Armaflex

• UT Solaflex • Tubolit

Specifications Test MethodAP Armaflex FS Tubes, Sheet & Rolls

AP Armaflex Tubes

AP Armaflex Sheet, Rolls, Duct Liner/Wrap AP Coilflex

AC Accoflex Tubes NH Armaflex UT Solaflex ArmaTuff Tubolit

Thermal Conductivity, Btu • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C) 90°F mean temperature (32°C) ASTM C 177 or C 518

0.28 (0.040) 0.286 (0.041)

0.25 (0.036) 0.256 (0.037)

0.25 (0.036) 0.256 (0.037)

0.27 (0.039) 0.226 (0.040)

0.27 (0.039)0.276 (0.040)

0.28 (0.046)0.286 (0.041)

0.25 (0.036)0.256 (0.037) 0.25 (0.036)

Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] ASTM E 96, Procedure A 0.08 [1.16 x 10 -13] 0.05 [0.725 x 10 -13]

0.05 [0.725 x 10 -13] (AP Armaflex) 0.08 [1.16 x 10 -13] 0.05 [0.725 x 10 -13] 0.08 [1.16 x 10 -13]

0.05 [7.25 x 10 -13] 0.00 Laminate

0.00 [0.0 x 10 -13]

Flame Spread and Smoke Developed Index ASTM E 84

CAN ULC S-1021-1/2" and 2" Thick 25/50

25/50UL94 V-5VA 25/50 25/50

30/200 Meets EB 4013, SOLAS,USN test. Toxicity-free* UL94 V-O

25/50 UL-94-V-0 (for exterior application) 25/50

Microban Antimicrobial Protection — Yes Yes Yes No No No No No

Mold Growth Fungi Resistance Bacterial Resistance

UL181ASTM G21/C1338ASTM G22

Meets Requirements

Meets Requirements

Meets Requirements

Meets Requirements

Meets Requirements

Meets Requirements

Meets Requirements

Meets Requirements

Water Absorption, % by Volume ASTM C 209 0.2 0.2 0.2 0.2 0.2 0.20.2 0.0 Laminate 0.2

Upper Use Limit — 220°F (105°C) 220°F (105°C) 180°F (82°C) 220°F (105°C) 250°F (120°C) 300°F (150°C) 180°F (82°C) 200°F (93°C)

Lower Use Limit ➀ — -297°F (-183°C) -297°F (-183°C) -297°F (-183°C) -297°F (-183°C) -297°F (-183°C) -297°F (-183°C) -297°F (-183°C) -200°F (-129°C)

Ozone Resistance ASTM C 1071 Excellent Good Good Good Excellent Excellent Excellent Good

Ultraviolet (UV) Resistance QUV Chamber Test Excellent — — Excellent — Excellent Excellent —

Third Party Certification Factory Mutual Approvals Yes Yes Yes — Yes — Excellent —

GREENGUARD Certified IAQ Yes Yes Yes — Yes Yes — Yes

GREENGUARD Certified for Children and Schools Yes Yes Yes — Yes Yes Yes Yes

➀ At temperatures below -20°F (-29°C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation. For applications of -40°F to -297°F (-40°C to -183°C) contact Armacell.

Product Selector

Armacell Product Specs

Page 3: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

Armacell Product Selector | www.armacell.us | 3

Application REFRIGERATION, HOT & COLD LINES,CHILLED WATER

HVAC INTERIOR & ExTERIOR DUCT SYSTEMS

MECHANICAL SYSTEMS,CHILLERS

MECHANICAL SYSTEMS,CHILLERS

INDUSTRIAL,PHARMACEUTICAL,MARINE & OFFSHORE

SOLAR RESIDENTIALPLUMBING

ProductRequirements

• Energy saving• Code compliant• Thermally efficient• Moisture resistant• Mold resistant• 25/50 rating• Low VOC,

formaldehyde free• Fiber free

• Energy saving• Code compliant• 25/50 rating• Tough, durable• Flexible

• Energy saving• Code compliant• Moisture resistant• Mold resistant• 25/50 rating• Fiber free• Noise blocking• Outdoors:

Maintenance-free, UV-resistant

• Energy saving• Code compliant• Thermally efficient• Moisture resistant• Mold resistant• 25/50 rating• Sheet & roll forms• Easy to cut and

fabricate

• Energy saving• Code compliant• Thermally efficient• Moisture resistant• Mold resistant• 25/50 rating• Sheet & roll forms• Easy to cut and fabricate

• Energy saving• Thermally efficient• Moisture resistant• 25/50 rating• Flexible• Durable, UV-resistant

outdoors

• Energy saving• Code compliant• Thermally efficient• High temperature range

for solar collectors• Mold resistant• Flexible

• Energy saving• Economical• Thermally efficient• Moisture resistant• 25/50 rating• Fiber free• Noise blocking

RecommendedProduct

• AP Armaflex, AP Armaflex SS (Self-Seal)

• Armaflex Coil• AP Armaflex W

• AP Armaflex, AP Armaflex SS

• AC Accoflex• Armaflex Coil

• AP Armaflex Self-Adhering (SA) Duct Liner/Wrap and AP Armaflex SA Sheet

• AP Coilflex

• AP Armaflex• AP Armaflex

Sheet and Rolls

• AP Armaflex• AP Armaflex Sheet

and Rolls

• AP Armaflex• Arma-Chek• NH Armaflex

• UT Solaflex • Tubolit

Specifications Test MethodAP Armaflex FS Tubes, Sheet & Rolls

AP Armaflex Tubes

AP Armaflex Sheet, Rolls, Duct Liner/Wrap AP Coilflex

AC Accoflex Tubes NH Armaflex UT Solaflex ArmaTuff Tubolit

Thermal Conductivity, Btu • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C) 90°F mean temperature (32°C) ASTM C 177 or C 518

0.28 (0.040) 0.286 (0.041)

0.25 (0.036) 0.256 (0.037)

0.25 (0.036) 0.256 (0.037)

0.27 (0.039) 0.226 (0.040)

0.27 (0.039)0.276 (0.040)

0.28 (0.046)0.286 (0.041)

0.25 (0.036)0.256 (0.037) 0.25 (0.036)

Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] ASTM E 96, Procedure A 0.08 [1.16 x 10 -13] 0.05 [0.725 x 10 -13]

0.05 [0.725 x 10 -13] (AP Armaflex) 0.08 [1.16 x 10 -13] 0.05 [0.725 x 10 -13] 0.08 [1.16 x 10 -13]

0.05 [7.25 x 10 -13] 0.00 Laminate

0.00 [0.0 x 10 -13]

Flame Spread and Smoke Developed Index ASTM E 84

CAN ULC S-1021-1/2" and 2" Thick 25/50

25/50UL94 V-5VA 25/50 25/50

30/200 Meets EB 4013, SOLAS,USN test. Toxicity-free* UL94 V-O

25/50 UL-94-V-0 (for exterior application) 25/50

Microban Antimicrobial Protection — Yes Yes Yes No No No No No

Mold Growth Fungi Resistance Bacterial Resistance

UL181ASTM G21/C1338ASTM G22

Meets Requirements

Meets Requirements

Meets Requirements

Meets Requirements

Meets Requirements

Meets Requirements

Meets Requirements

Meets Requirements

Water Absorption, % by Volume ASTM C 209 0.2 0.2 0.2 0.2 0.2 0.20.2 0.0 Laminate 0.2

Upper Use Limit — 220°F (105°C) 220°F (105°C) 180°F (82°C) 220°F (105°C) 250°F (120°C) 300°F (150°C) 180°F (82°C) 200°F (93°C)

Lower Use Limit ➀ — -297°F (-183°C) -297°F (-183°C) -297°F (-183°C) -297°F (-183°C) -297°F (-183°C) -297°F (-183°C) -297°F (-183°C) -200°F (-129°C)

Ozone Resistance ASTM C 1071 Excellent Good Good Good Excellent Excellent Excellent Good

Ultraviolet (UV) Resistance QUV Chamber Test Excellent — — Excellent — Excellent Excellent —

Third Party Certification Factory Mutual Approvals Yes Yes Yes — Yes — Excellent —

GREENGUARD Certified IAQ Yes Yes Yes — Yes Yes — Yes

GREENGUARD Certified for Children and Schools Yes Yes Yes — Yes Yes Yes Yes

➀ At temperatures below -20°F (-29°C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation. For applications of -40°F to -297°F (-40°C to -183°C) contact Armacell.

Page 4: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

4 | Armacell Product Selector | www.armacell.us

AP Armaflex®, AP Armaflex® W and AP Armaflex® SS (Self-Seal) Pipe Insulation through 1” Wall

Factory Mutual (FM) Approvals

AP Armaflex is approved through continuing supervision by Factory Mutual Approvals:

• Thermal Conductivity: 0.25 BTU-in/hr. ft2 °F• Water Vapor Transmission: 0.05 perm-inch• Fire Rating: will not contribute significantly to fire (simulated end-use

testing)

Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified.

Uses & Application

• Retards heat gain and controls condensation drip from chilled-water and refrigeration systems. Reduces heat flow for hot-water plumbing, liquid-heating and dual temperature piping.

• Acceptable for use in air plenums. 25/50-rated through 1” (25 mm).• Normally requires no supplemental vapor-retarder protection.• Armaflex insulation installs with Armaflex 520 Adhesive. However,

Self-Seal (SS) saves labor and installed costs – only the butt joints require adhesive coating.

• For below ground applications, contact Armacell or see Technical Bulletin No. 7 on our website, www.armacell.us.

• Outdoors, a weather-resistant protective finish is to be applied. Armaflex WB Finish is recommended.

Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure.

Specification Compliance

Specifications Values Test Method

Thermal Conductivity, BTU • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C)90°F mean temperature (32°C)

0.25 (0.036) 0.256 (0.037) ASTM C 177 or ASTM C 518

Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.05 [0.725 x 10-13] ASTM E 96, Procedure A

Flame Spread and Smoke Developed Index 25/50* ASTM E 84

CAN/ULC S102 ➂

Mold Growth Fungi Resistance Bacterial Resistance

Meets requirementsUL181 ASTM G21/C1338 ASTM G22

Water Absorption, % by Volume 0.2% ASTM C 209

Upper Use Limit ➀ 220°F (-183°C)** —

Lower Use Limit ➁ -297˚F (-183˚C)* —

Ozone Resistance Good —

Sizes Wall thickness, (nominal) Inside diameter, tubular Length of sections, tubular

3/8”, 1/2”, 3/4”, 1”, (10, 13, 19 and 25mm) 3/8” ID to 8” ID* (10mm ID to 203mm) 6’ (1.8m)

Notes

➀ On the heating cycle, AP Armaflex SS Pipe Insulation withstand temperatures as high as 220°F (105°C). 520, 520 Black or 520 BLV Adhesive may be used with pipe insulation applications up to 220°F (105°C).

➁ At temperatures below -20°F (-29°C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation.

➂ AP Armaflex Black tested for CAN/ULC. AP Armaflex White determined to be comparable.

* For applications of -40°F to -297°F (-40°C to -183°C), contact Armacell.

• ASTM C 534, Type I — Tubular Grade 1

• ASTM E 84, NFPA 255, UL 723• CAN/ULC S102• UL 94 5V-5A, V-O, File E 55798• NFPA 90A, 90B• UL 181• ASTM G-21/C1338,

• ASTM G-22• ASTM D 1056, 2B1• MIL-P-15280J, FORM T (Black)• MIL-C-3133C (MIL STD 670B),

Grade SBE 3* — Black only• MEA 96-85-M*• City of LA – RR 7642*

* Non-SS (Self-Seal) only

AP Armaflex, AP Armaflex W and AP Armaflex SS (Self-Seal) Pipe (Tube) Insulation is a black or white closed cell, fiber-free elastomeric foam and the world’s most recognized brand of flexible mechanical insulation. Self-seal version enables faster, labor saving installation.

• Code Compliant: 25/50-rated through 1” wall. Acceptable for use in air plenums.

• Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required.

• Mold resistant: Made with EPA-registered Microban® antimicrobial product protection.

• Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes.

• Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools.

• Durable: No fragile vapor retarder and lasts the life of the mechanical system.

Page 5: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

Armacell Product Selector | www.armacell.us | 5

AP Armaflex® FS Pipe Insulation 1-1/2” and 2” (38 mm and 50 mm) Wall

Factory Mutual (FM) Approvals

AP Armaflex is approved through continuing supervision by Factory Mutual Approvals:

• Thermal Conductivity: 0.28 BTU-in/hr. ft2 °F• Water Vapor Transmission: 0.08 perm-inch• Fire Rating: will not contribute significantly to fire (simulated

end-use testing)

Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified.

Uses & Application

• Retards heat gain and controls condensation drip from chilled-water and refrigeration systems. Reduces heat flow for hot-water plumbing, liquid-heating and dual temperature piping.

• Acceptable for use in air plenums. 25/50-rated through 2”.• Normally requires no supplemental vapor-retarder protection.• For below ground applications, contact Armacell or see Technical

Bulletin No. 7 on our website, www.armacell.us.• Outdoors, a weather-resistant protective finish is to be applied.

Armaflex WB Finish is recommended.

Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure.

Specification Compliance

Specifications Values Test Method

Thermal Conductivity, BTU • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C) 90°F mean temperature (32°C)

0.28 (0.040) 0.256 (0.037) ASTM C 177 or ASTM C 518

Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.08 [1.16 x 10-13] ASTM E 96, Procedure A

Flame Spread and Smoke 25/50 ASTM E 84

Mold Growth Fungi Resistance Bacterial Resistance

Meets requirementsUL181 ASTM G21/C1338 ASTM G22

Water Absorption, % by Volume 0.2% ASTM C 209

Upper Use Limit ➀ 220˚F (105˚C)

Lower Use Limit ➁ -297˚F (-183˚C) ASTM C 534

Ozone Resistance Good —

Sizes Tubes Wall Thickness (nominal) Form Inside Diameter Tubular Form Length

1-1/2” and 2” (38mm and 50mm) 3/8” to 6” IPS (10mm - 173mm) 6’ (1.8m)

Notes

➀On the heating cycle, AP Armaflex Pipe Insulation will withstand temperatures as high as 220°F (105°C). 520, 520 Black or 520 BLV Adhesive may be used with pipe insulation applications up to 220°F (105°C).

➁ At temperatures below -20°F (-29°C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency and resistance to water vapor permeability of Armaflex insulation.

For applications of -40°F to -297°F (-40°C to -183°C), contact Armacell.

• ASTM C 534, Type I and II — Tubular Grade 1

• ASTM C 1534• ASTM E 84, NFPA 255, UL 723• UL 94 5VA, File E 55798• NFPA 90A, 90B• UL 181

• ASTM G-21/C1338• ASTM G-22• ASTM D 1056, 2B1• MEA 96-85-M• City of LA – RR 7642

AP Armaflex FS Insulation is a black or white closed cell, fiber-free elastomeric foam, a code compliant 1-1/2” and 2” thick EPDM version of the world’s most recognized brand of mechanical insulation.

• Code Compliant in greater thicknesses: 25/50-rated in 1-1/2” and 2” wall. Acceptable for use in air plenums.

• Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required.

• Mold resistant: Made with EPA-registered Microban® antimicrobial product protection.

• Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes.

• Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools.

• Durable: No fragile vapor retarder and lasts the life of the mechanical system.

Page 6: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

6 | Armacell Product Selector | www.armacell.us

AP Armaflex® Sheet & Roll Insulation and AP Armaflex® SA Self-Adhering Sheet & Roll Insulation

Factory Mutual (FM) Approvals

AP Armaflex is approved through continuing supervision by Factory Mutual Approvals:

• Thermal Conductivity: 0.25 BTU-in/hr. ft2 °F• Water Vapor Transmission: 0.05 perm-inch• Fire Rating: will not contribute significantly to fire (simulated end-use

testing)

Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified.

Uses & Application

• Retards heat gain and controls condensation drip from chilled-water and refrigeration systems. Reduces heat flow on hot systems.

• Acceptable for use in air plenums. 25/50-rated through 1” (25 mm).• Normally requires no supplemental vapor-retarder protection.• Armaflex insulation installs with Armaflex 520 Adhesive. However,

Self-Adhering (SA) saves labor and installed costs – only the joints require adhesive coating.

• For below ground applications, contact Armacell or see Technical Bulletin No. 7 on our website, www.armacell.us.

• Outdoors, a weather-resistant protective finish is to be applied. Armaflex WB Finish is recommended.

Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure.

Specification Compliance

Specifications Values Test Method

Thermal Conductivity, BTU • in./h • ft2 • °F (W/mK) 75°F Mean Temperature (24°C)90°F Mean Temperature (32°C)

0.25 (0.036)0.256 (0.037) ASTM C 177 or ASTM C 518

Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.05 [0.725 x 10-13] ASTM E 96, Procedure A

Flame Spread and Smoke Developed Index through 1” (25mm)*

25/50 ASTM E 84 CAN/ULC S102

Mold Growth Fungi Resistance Bacterial Resistance

Meets requirementsUL181 ASTM G21/C1338 ASTM G22

Water Absorption, % by Volume 0.2% ASTM C 209

Upper Use Limit ➀ 180/220°F (82/105°C) —

Lower Use Limit ➁ -297°F (-183°C)** —

Ozone Resistance Good —

Sizes: Sheet Width

Thickness (nominal) x Length

36” x 48” (.915m x1.22m)1/8”, 1/4”, 3/8”, 1/2”, 3/4”, 1”, 1-1/2” & 2”(3, 6, 10, 13, 19, 25, 38 & 50mm)

Sizes: Roll Width

Thickness (nominal) x Length

48” (1.22mm) 60” (1.53m) in 1” thickness only3/8” x 100’ (10mm x 30.5m)1/2” x 70’ (13mm x 21.4m)3/4” x 50’ (19mm x 15.2m)1” x 35’ (25mm x 10.7m)1-1/2” x 25’ (38mm x 7.6m)2” x 18’ (50mm x 5.4m)

Notes

➀ When AP Armaflex Sheet is installed by adhering butt joints and seams only, the upper temperature limit is 220°F (105°C) using 520, 520 black, or 520 BLV Adhesive. AP Armaflex Sheet adhered with complete adhesive coverage on flat or curved metal surfaces may be applied to surfaces that will operate as high as 180°F (82°C) using 520, 520 Black, 520 BLV or Armaflex Low VOC Spray Contact Adhesive.

➁ At temperatures below -20°F (-29°C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation.

➂ Reference only.

* For 25/50 above 1” (25mm), Please see AP Armaflex FS submittal. 1-1/2” and 2” available in 25/50 and non 25/50.

** For applications of -40°F to -297°F (-40°C to -183°C), contact Armacell.

• ASTM C 534, Type II — Sheet Grade 1

• ASTM C 1534• ASTM E 84, NFPA 255, UL 723• CAN/ULC S102 (25 mm)• UL 94 5V-5A, V-O, File E 55798• NFPA 90A, 90B• UL 181

• ASTM G-21/C1338,• ASTM G-22• ASTM D 1056, 2B1• MIL-P-15280J, FORM S• MIL-C-3133C (MIL STD 670B),

Grade SBE 3• MEA 107-89M• City of LA – RR 7642

AP Armaflex and AP Armaflex SA Self-Adhering Sheet & Roll Insulation is a black closed cell, fiber-free elastomeric foam and the world’s most recognized brand of flexible mechanical insulation. Self-adhering version enables faster, labor saving installation.

• Code Compliant: 25/50-rated through 1” wall. Acceptable for use in air plenums.

• Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required.

• Mold resistant: Made with EPA-registered Microban® antimicrobial product protection.

• Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes.

• Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools.

• Durable: No fragile vapor retarder and lasts the life of the mechanical system.

Page 7: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

Armacell Product Selector | www.armacell.us | 7

AP Armaflex® FS Sheet & Roll Insulation 1-1/2” and 2” (38 mm and 50 mm) Thickness

Factory Mutual (FM) Approvals

AP Armaflex is approved through continuing supervision by Factory Mutual Approvals:

• Thermal Conductivity: .28 BTU-in/hr. ft2 °F• Water Vapor Transmission: 0.08 perm-in• Fire Rating: 25/50 through 2” thickness

Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified.

Uses & Application

• Retards heat gain and controls condensation drip from chilled-water and refrigeration systems. Reduces heat flow on hot systems.

• Acceptable for use in air plenums. 25/50-rated through 2” (50 mm).• Normally requires no supplemental vapor-retarder protection.• Armaflex insulation installs with Armaflex 520 Adhesive.• For below ground applications, contact Armacell or see Technical

Bulletin No. 7 on our website, www.armacell.us.• Outdoors, a weather-resistant protective finish is to be applied.

Armaflex WB Finish is recommended.

Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure.

Specification Compliance

Specifications Values Test Method

Thermal Conductivity, BTU • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C)

0.28 (0.040) ASTM C 177 or ASTM C 518

Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.08 [1.16 x 10-13] ASTM E 96, Procedure A

Flame Spread and Smoke Developed Index through 2” (50mm)

25/50 ASTM E 84

Mold Growth Fungi Resistance Bacterial Resistance

Meets requirementsUL181 ASTM G21/C1338 ASTM G22

Water Absorption, % by Volume 0.2% ASTM C 209

Upper Use Limit 180˚F (82˚C) —

Lower Use Limit ➀ -297˚F (-183˚C) —

Ozone Resistance Good —

Sizes: Sheet Width Thickness (nominal) x Length

36” x 48” (.915m x 1.22m) 1-1/2” and 2” (38 and 50mm)

Sizes: Roll Width

Thickness (nominal) x Length

48” (1.22mm) and 60” (1.53m)† 1-1/2” x 25’ (38mm x 7.6m) 2” x 18’ (50mm x 5.4m)

Notes

➀ At temperatures below -20°F (-29°C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency and resistance to water vapor permeability of Armaflex insulation.

➁Reference Only

* For applications of -40°F to -297°F (-40°C to -183°C), contact Armacell.

• ASTM C 534, Type II — Sheet Grade 1

• ASTM C 1534• ASTM E 84, NFPA 255, UL 723• UL 94 5VA, File E 55798• NFPA 90A, 90B• UL 181

• ASTM G-21/C1338,• ASTM G-22• ASTM D 1056, 2B1• MEA 96-85M• City of LA – RR 7642

AP Armaflex FS Sheet & Roll Insulation is a black closed cell, fiber-free elastomeric foam, a code compliant 1-1/2” and 2” thick EPDM version of the world’s most recognized brand of mechanical insulation.

• Code Compliant in greater thicknesses: 25/50-rated in 1-1/2” and 2”. Acceptable for use in air plenums.

• Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required.

• Mold resistant: Made with EPA-registered Microban® antimicrobial product protection.

• Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes. R-Value rated R-8 at 2” thickness.

• Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools.

• Durable: No fragile vapor retarder and lasts the life of the mechanical system.

Page 8: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

8 | Armacell Product Selector | www.armacell.us

AP Armaflex® SA and AP Armaflex® FS Duct Liner

Factory Mutual (FM) Approvals

AP Armaflex is approved through continuing supervision by Factory Mutual Approvals:

• Thermal Conductivity: AP Armaflex: 0.25, AP Armaflex FS 0.08 BTU-in/hr. ft2 °F

• Water Vapor Transmission: AP Armaflex: 0.05, AP Armaflex FS 0.08 perm-in

• Fire Rating: 25/50 through 2” thickness ➀

Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified.

Uses & Application

• Ideal for air handling systems, VAV units, ducts and other air system components requiring condensation control, or resistance to moisture, damage or heat gain.

• Excellent for reducing HVAC noise, especially in low frequency ranges. Performance peaks at 500 Hz, a critical frequency in a duct system.

• Application areas include schools, hospitals, hotels, commercial and public buildings.

• Acceptable for use in air plenums. AP Armaflex SA 25/50-rated through 1” (25 mm). Where 25/50-rated R-6 or R-8 is required, select AP Armaflex FS in 1-1/2” or 2” thicknesses.

Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure.

Specification Compliance • ASTM C 534, Type II — Sheet

Grade 1• ASTM C 1534• ASTM E 84, NFPA 255, UL 723• CAN/ULC S102 (25 mm)• UL 94 5VA, File E 55798• NFPA 90A, 90B• UL 181

• ASTM G-21/C1338,• ASTM G-22• ASTM D 1056, 2B1• MIL-P-15280J, FORM S• MIL-C-3133C (MIL STD 670B),

Grade SBE 3• MEA 107-89M• City of LA – RR 7642

AP Armaflex SA (Self-Adhering) and AP Armaflex FS Black Duct Liners are patented*, non-fibrous duct liner with an advanced pressure sensitive adhesive system for non-pinned applications. They can also be applied as a duct wrap to existing duct work.

• Code Compliant in greater thicknesses: 25/50-rated through 2”. Acceptable for use in air plenums.

• Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required.

• Mold resistant: Made with EPA-registered Microban® antimicrobial product protection.

• Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes.

• Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools.

• Durable: No fragile vapor retarder and lasts the life of the mechanical system.

• Self-Adhering (SA) system saves labor and installed costs – only the joints require adhesive coating.

US Patent 5971034 – “Thermal Duct Lining Insulation” for lining variable air volume boxes, air handling units, and ducts for heat ventilation and air conditioning

Specifications Values Test Method

Thermal Conductivity, Btu • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C) 90°F mean temperature (32°C)

AP Armaflex AP Armaflex FS

0.25 (0.036) 0.256 (0.037)

0.28 (0.040) 0.286 (0.041) ASTM C 177 or C 518

Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.05 [0.725 x 10-13] 0.08 [1.16 x 10-13] ASTM E 96, Procedure A

Flame Spread and Smoke Developed Index ➀

Through 1” (25 mm) 25/50

1-1/2” and 2” 25/50

ASTM E 84 CAN ULC S-102 – AP through 1”

Mold Growth Fungi Resistance Bacterial Resistance

Meets requirementsUL181 ASTM G21/C1338 ASTM G22

Water Absorption, % by Volume 0.2% ASTM C 209

Upper Use Limit ➁ 180˚F (82˚C)

Lower Use Limit ➂ -297˚F (-183˚C)

Erosion Resistance Does not break away, flake off or show evidence or delamination at velocities of 10,000 ft/min ASTM C 1071

Corrosiveness Noncorrosive ASTM C 665

Odor Emissions No objectionable odors ASTM C 665

Notes

➀AP Armaflex SA Duct Liner has a flame spread index of less than 25 and a smoke developed index of less than 50 for all thicknesses up to and including 1” (25 mm) when tested according to ASTM E 84 and CAN ULC S-102.

AP Armaflex FS has a flame spread index of less than 25 and a smoke developed index of less than 50 for all thicknesses up to and including 1-1/2” and 2” when tested according to ASTM E 84 and CAN ULC S-102. Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified.

➁ Withstands temperature of 250°F (121°C) when tested according to ASTM C 411. “Test Method for Surface Performance of High-Temperature Insulations”. At this temperature, AP/Armaflex SA Duct Liner insulation shows no evidence of flaming, glowing, smoldering, delamination, melting or insulation collapse. Although this insulation will withstand high temperatures, continuous use temperature should be limited to 180°F (82°C).

➂ At temperatures below -20°F (-29°C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation.

Page 9: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

Armacell Product Selector | www.armacell.us | 9

Features Benefits

Advanced, aggressive PSA No pinning required, faster installation

Closed cell structure

Resists moisture, nonwickingReduced water presence in system and insulationNoise blockingNondusting Longer life Won’t contribute to air quality problems

Made with Microban antimicrobial product protection

Resists mold on the insulation EPA registered for use in air duct insulation

Smooth surface that reduces dirt and debris accumulation

Inhibits amplification of biological contaminants Basis for continuing system hygiene

Elastomeric material

Fiber free Resistant to incidental damage No special tools; no dust mask required during fabrication and installation

Inherent vapor retarder Requires no mastics Competitive total installed cost

† ASTM C 423 with ASTM E 795 Type “A” Mounting

* US Patent 5971034 – “Thermal Duct Lining Insulation” for lining variable air volume boxes, air handling units, and ducts for heat ventilation and air conditioning.

Sound Absorption Coefficients at Frequency

Thickness STC Class

Nom. 1/2” (13 mm) 25

Nom. 1” (25 mm) 25

Sound Transmission Class (STC) Sizes

Sheet Width / Length 36” x 48”

Roll Width 48” (all thicknesses) and 60” (1” only)

Wall Thickness AP Armaflex: 3/8”, 1/2”, 3/4” and 1”AP Armaflex FS: 1-1/2” and 2”

Thickness 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC†

Nom. 1” (25 mm) 0.01 0.13 0.39 0.69 0.29 0.26 0.40

AP Armaflex SA and AP Armaflex FS Black Duct Liners / WrapsPatented* for Air Systems that Require an Alternative Duct Liner / Wrap

Page 10: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

10 | Armacell Product Selector | www.armacell.us

AP Coilflex® Conformable Duct Liner

Ratings

• Thermal Conductivity: 0.25 BTU-in/hr. ft2 °F• Fire Rating: will not contribute significantly to fire (simulated end-use

testing)

Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified.

Uses & Application

• Ideal for air handling systems, VAV units, ducts and other air system components requiring condensation control, or resistance to moisture, damage or heat gain.

• Excellent for reducing HVAC noise, especially in low frequency ranges. Performance is twice as effective as fiberglass at 500 Hz, a critical frequency in a duct system.

• Application areas include schools, hospitals, commercial buildings.

• Acceptable for use in air plenums. 25/50-rated through 1” (25 mm).

• Normally requires no supplemental vapor-retarder protection.

Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure.

Specification Compliance • ASTM C 534, Type II — Sheet

Grade 1• ASTM C 1534• ASTM E 84, NFPA 255, UL 723• CAN/ULC S102 (25 mm)• UL 94 5VA, File E 55798

• NFPA 90A, 90B• UL 181• ASTM G-21/C1338,• ASTM G-22• ASTM D 1056, 2B1

AP Coilflex Duct Liner is a patent-pending*, cost-effective, and highly conformable non-fibrous acoustic duct liner created for automated applications with water-based adhesives in accordance with SMACNA pinning and spacing guidelines, or unpinned applications using an Armaflex 520 Adhesive. It can also be applied as a duct wrap to existing duct work.

• Practical and Cost Saving: Easily conforms to fabricated duct corners without stiffness or bulging and compression; requires fewer cuts and expensive encapsulation or inner wall.

• Exceptional Acoustic Performance: Superior sound absorption at low frequencies critical top speech intelligibility.

• Mold resistant: Made with EPA-registered Microban® antimicrobial.• Energy efficient: Contributes toward LEED Certification, meets the

energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes. R-Value of 4.2.

• Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools.

• Durable: No fragile vapor retarder and lasts the life of the mechanical system.

* US Patent 5971034 – “Thermal Duct Lining Insulation” for lining variable air volume boxes, air handling units, and ducts for heat ventilation and air conditioning

Specifications Values Test MethodThermal Conductivity, Btu • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C) 90°F mean temperature (32°C)

0.25 (0.036) 0.256 (0.037) ASTM C 177 or C 518

Flame Spread and Smoke Developed Index ➀Through 1” (25 mm) 25/50 ASTM E 84

Mold Growth Fungi Resistance Bacterial Resistance

Meets requirementsUL181 ASTM G21/C1338 ASTM G22

Upper Use Limit ➁ 180˚F (82˚C) —

Lower Use Limit ➂ -297˚F (-183˚C) —

Erosion Resistance Does not break away, flake off or show evidence or delamination at velocities of 10,000 ft/min ASTM C 1071

Corrosiveness Noncorrosive ASTM C 665

Odor Emissions No objectionable odors ASTM C 665

Thickness STC ClassNom. 1/2” (13 mm) 25

Nom. 1” (25mm) 25

Sound Transmission Class (STC) Sizes

Roll Width 46”, 47”, 48” , 56-1/4”, 59” and 60”

Wall Thickness 1” 1/2” (special order)

Sound Absorption Coefficients at Frequency

Thickness 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC†

Nom. 1” (25mm) 0.08 0.22 1.03 0.37 0.68 0.50 0.60

Notes

➀AP Coilflex Duct Liner has a flame spread index of less than 25 and a smoke developed index of less than 50 for all thicknesses up to and including 1” (25 mm) when tested according to ASTM E 84. Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified.

➁Withstands temperature of 250°F (121°C) when tested according to ASTM C 411. “Test Method for Surface Performance of High-Temperature Insulations”. At this temperature, AP Coilflex Duct Liner insulation shows no evidence of flaming, glowing, smoldering, delamination, melting or insulation collapse. Although this insulation will withstand high temperatures, continuous use temperature should be limited to 180°F (82°C).

➂At temperatures below -20°F (-29°C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency of Coilflex insulation.

† ASTM C 423 with ASTM E 795

Type “A” Mounting

Page 11: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

Armacell Product Selector | www.armacell.us | 11

NH Armaflex® Pipe, Sheet & Roll Insulation and NH Armaflex SA Roll Insulation

Uses & Application

• Closed-cell material that eliminates toxic gases that may threaten personnel and sensitive electronic equipment including effects from chlorines, bromines and PVC.

• Used as insulation and protection for piping, tanks, and air ducts, and to prevent stress corrosion with stainless steel pipes in the following applications:

• US Navy applications • General shipbuilding • IMO (International Maritime Organization) • Nuclear power plants • Other areas where nonhalogenated or chlorine-free materials

may be required

Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure.

Specification Compliance

Specifications Values Test Method

Thermal Conductivity, BTU • in./h • ft2 • °F (W/mK) 32°F mean temperature (0°C)75°F mean temperature (24°C) 104°F mean temperature (40°C)

0.248 (0.036) 0.27 (0.039) 0.282 (0.041) ASTM C 177 or ASTM C 518

Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.05 [0.725 x 10-13] ASTM E 96, Procedure A

Mold Growth Fungi Resistance Bacterial Resistance

Meets requirementsUL181 ASTM G21/C1338 ASTM G22

Water Absorption, % by Volume 0.2% ASTM C 209

Upper Use Limit 250˚F (120˚C) —

Lower Use Limit ➀ -297˚F (-183˚C) ASTM C 534

Ozone Resistance Excellent ASTM D 1149

Toxicity Free from Halogen/Dioxin/CFC/Mercury/Carbon Black/Heavy Metal —

IMO (International Organization)

Combustion Gas Concentration (Pass) Smoke Density (Pass) Heat Release Rate (Pass) Flame Spread (Pass)

Navy Large Marinetime Scale Pipe Insulation Room/ Corner Test

Behavior in Fire

Does not support progressive flaming, will not melt or drip. Meets EB 4013 Meets IMO SOLAS requirements

Notes

➀At temperatures below -20°F (-29°C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation.

Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified.

• Electric Boat Corporation Specification EB 4013 Antisweat and Refrigerant Insulation Systems (Sheets and Tubes)

• International Maritime Organization (IMO) SOLAS Requirements

• United States Coast Guard Requirements*

• NH Armaflex is currently specified for use on US Navy vessels

• UL-V-O and HF-1 File Number E55798

• ASTM C534 Type 1 (Tubular) Grade 3, Type II (Sheet) Grade 3

• ASTM C795• Nuclear Regulatory Commission

Regulatory Guide 1.36

NH Armaflex Insulation is a nonhalogen elastomeric insulation developed for sweat control in environments that require specific protection against smoke containing acid gases. It is also available self-adhering (SA) in roll form.

• Innovative: The first nonhalogen flexible insulation introduced for shipboard use.

• Safety first: Fire tested at the Naval Research Laboratory (NRL) in controlled comparisons with baseline materials. Further testing through DDG-51 and NSSN produced references that NH Armaflex scored better than MIL-P-15280J materials such as AP Armaflex.

• Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required.

• Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. SA (Self-adhering) is the reduced VOC version.

• Durable: No fragile vapor retarder and lasts the life of the mechanical system.

Nominal SizesThickness

1/2” (13 mm)

3/4” (19 mm)

1” (25 mm)

1-1/2” (38 mm)

Tube 6’ (1.8 m) in length Available in nominal pipe sizes from 3/8” to 8” (1” thickness special order)

Not Available

Sheet 3’ x 4’ (0.915 m X 1.22 m) Available

Roll 4’ (1.22 m) width 70’ (21.4 m) length

50’ (15.2 m) length

35’ (10.7 m) length

25’ (7.6 m) length

*Available special order only.

Page 12: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

12 | Armacell Product Selector | www.armacell.us

UT Solaflex™ Pipe Insulation Uses & Application

• Closed-cell structure provides low thermal conductivity, excellent fire and smoke behavior, low temperature flexibility and excellent protection against water vapor diffusion.

• No painting is necessary for performance of the product. (However, all elastomeric-based cellular insulation will show surface defects after prolonged exposure to UV radiation. Painting will minimize these defects.)

• Performs on a broad range of metal pipes and tubing in piping and collectors, refrigeration-hot gas and dual temperature piping, automotive (under hood) and low pressure steam lines.

• Oil-resistant as tested by ASTM Oil No. 1 and No. 3.

Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure.

Specification Compliance

Specifications Values Test Method

Thermal Conductivity, BTU • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C)

0.28 (0.040) ASTM C 177 or ASTM C 518

Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.08 [1.16 x 10-13] ASTM E 96, Procedure A

Flame Spread and Smoke Developed Index through 1” (25mm)

25/50 ASTM E 84

Mold Growth Fungi Resistance Bacterial Resistance

Meets requirements UL181 ASTM G21/C1338 ASTM G22

UV Weather Resistance Excellent QUV Chamber Test ASTM G90 (EMMAQUA)

Upper Use Limit ➀ 300˚F (150˚C) —

Lower Use Limit ➁ -297˚F (-183˚C) —

Ozone Resistance Excellent ASTM D 1149

Sizes: Tubes Wall thickness, (nominal) Inside diameter, tubular Length of sections, tubular

1/2”, 3/4”, 1” (13, 19, 25mm) 1/2” through 2-1/2” IPS (13mm to 63.5mm) 6’ (1.8m)

Sizes: Rolls Width Thickness x Length

48” (1.2m) 1/2” x 70’ (13mm x 21.3m) 3/4” x 50’ (19mm) x 15.2 m) 1” x 35’ (25mm x 10.7m)

Notes

➀ Suitable for systems with occasional or intermittent temperatures to 350°F (175°C), with a recommended exposure limit of one 30 minute period at 350°F (175°C) over 24 hours of operation.

➁ At temperatures below -20°F (-29°C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of UT Solaflex insulation.

UT Solaflex Tube and Roll Insulation is a UL-listed closed cell, fiber-free, 25/50-rated flexible EPDM elastomeric foam insulation for high temperature, UV-resistant and oil-resistant applications.

• Innovative: New generation of insulation for solar collectors, refrigeration (including hot gas piping) and automotive.

• High temperature: Remains flexible at temperatures up to +300°F (+150°C), with intermittent exposure to +350°F (+175°C).

• Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, resists mold. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools.

• Durable: No fragile vapor retarder and lasts the life of the mechanical system.

• ASTM C 534, Type I —• Tubular Grade 2, Type II (Sheet), Grade 2• UL 94 UL 94 5VA, V-P, File E 55798

Page 13: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

Armacell Product Selector | www.armacell.us | 13

ArmaTuff® Laminated Sheets and Rolls Uses and Applications

ArmaTuff is designed to be used for all exterior applications: Exterior ducts, tanks, vessels, large pipes and fittings. The laminate is resistant to UV, ozone, acid rain and most industrial pollutants. No painting is required.

Application

ArmaTuff is installed using Armaflex Adhesives or with pre-applied pressure sensitive adhesive (PSA) for application to large, flat or curved metal surfaces such as ducts, vessels, very large pipes or tanks. The seams must be installed in compression and sealed with Armaflex Adhesives. Cover the seam with ArmaTuff Seal Tape. Armaflex 520 Adhesive is a contact adhesive: therefore it must be applied to both surfaces, allowed to get tacky, and the surfaces joined with pressure. Exterior duct work must be pitched to allow rain water to run off the insulation.

ArmaTuff is designed for installation in above ground applications. Armaflex insulation products must be installed according to Installation of Armaflex Insulations brochure. Proper installation is required to assure Armaflex insulation performance. The application temperature should be above 40°F (+4°C) and 100°F (+38°C).

Finishing the Installation with ArmaTuff Seal Tape

ArmaTuff is a complete insulation system providing durable, UV-resistant and maintenance-free outdoor performance. Tape is backed with pressure sensitive adhesive and designed to provide protection along the seams and exposed edges of the insulation. Tape is supplied in rolls 6”-wide for sealing seams and exposed edges of ArmaTuff.

ArmaTuff is the premiere Armacell Coating System for outdoor applications. It provides a tough metal surface on Armaflex insulation for superior protection against ultraviolet radiation and punctures.

• Maintenance-free: UV- and damage resistant 10 mil laminate• Long-lasting protection: 10-year membrane limited warranty• Flexible application: Available with or without PSA• Color: White

Description

ArmaTuff is Armaflex insulation with a 12 mil laminated covering membrane. The membrane has a 10-year limited warranty against break-down due to UV radiation. Armaflex is a mold-resistant flexible elastomeric thermal insulation. Its closed-cell structure prevents condensation and moisture wicking, and makes it an efficient insulation. It is manufactured without the use of CFCs, HFCs or HCFCs.

It is available in 36” x 48” sheets (with or without pressure sensitive adhesive) and in rolls 48” wide (without PSA), in 1”, 1-1/2”, 2” thicknesses.

Specifications Values Test Method

Thermal Conductivity, Btu • in./h • ft2 • °F (W/mK) 75°F Mean Temperature (24°C) 90°F Mean Temperature (32°C)

0.25 (0.036) 0.256 (0.037) ASTM C 177 or C 518

Water Vapor Permeability, Perm-in. [Kg/(s•m•Pa)]

Laminate 0.00 Foam 0.05 ASTM E 96, Procedure A

Mold Growth Fungi Resistance Bacterial Resistance

Meets requirementsUL181 ASTM G21/C1338 ASTM G22

Water Absorption, % by Volume 0.2% / 0.0% laminate ASTM C 209

Upper Use Limit 180°F (82°C) —

Lower Use Limit ➀ -297°F (-183°C)* —

UltraViolet (UV) Resistance Excellent ASTM G 90 QUV Chamber

Chemical Resistance Excellent —

Weatherability Excellent ASTM D471

Durability Excellent —

Sizes: Sheet – With or Without Adhesive Width and Length Thickness (nominal)

36” x 48” (0.915 m x 1.22 m) 1”, 1-1/2” and 2” (25, 38 and 50 mm)

Sizes: Roll – Without Adhesive Width Thickness (nominal) x Length

48” (1.22 m) 1” x 35’ (25 mm x 10.7 m) 1-1/2” x 25’ (38 mm x 7.6 m) 2” x 18’ (50 mm x 5.4 m)

Notes

➀ At temperatures below -20°F (-29°C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of ArmaTuff.

➁ Reference only.

* For applications of -40°F to -297°F (-40°C to -183°C), contact Armacell.

Page 14: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

14 | Armacell Product Selector | www.armacell.us

Tubolit® Pipe Insulation, Tubolit® SS Self Seal, Tubolit® White SS, Tubolit® W Tape

Ratings

• Thermal Conductivity: 0.25 BTU-in/hr. ft2 °F• Water Vapor Transmission: 0.00 perm-inch• Fire Rating: 25/50

Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified.

Uses & Application

• Reduces heat loss on hot water plumbing and heat gain on cold-water plumbing systems.

• Recommended for use on lines operating from -200°F (-129°C) to 200°F (93°C).

• Normally requires no supplemental vapor-retarder protection.

• Tubolit insulation installs with Armaflex 520 Adhesive. However, Self-Seal (SS) products save labor and installed costs – only the butt joints require adhesive coating.

• Outdoors, a weather-resistant protective finish is to be applied. Armaflex WB Finish is recommended.

Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure.

Specification Compliance

Specifications Values Test Method

Thermal Conductivity, BTU • in./h • ft2 • °F (W/mK) 75°F (24°C) mean temperature 0.25 (0.036) ASTM C 177 or ASTM C 518

Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.0 ASTM E 96, Procedure A

Flame Spread and Smoke Developed Index through 1” (25 mm) Thickness ➁

25/50 ASTM E 84

Mold Growth Fungi Resistance Bacterial Resistance

Meets requirementsUL181 ASTM G21/C1338 ASTM G22

Upper Use Limit ➀ 180°F (-129°C) —

Lower Use Limit ➁ -200˚F (-129˚C) —

Ozone Resistance Good —

Sizes Wall Thickness (nominal) Inside Diameter, Tubular Length of Sections, Tubular Tape

3/8”, 1/2”, 3/4” and 1” (10, 13, 19 and 25 mm)3/8” to 4” IPS ID (10 mm to 114 mm ID)6” (1.83 m) 2” wide x 60’

Notes

➀ Average values are not to be used for writing material specifications. Contact Armacell for specification ranges.

➁ Cellular plastics and thermoplastics, such as polyethylene/polyolefin insulation, that may drip, melt, delaminate or draw away from the fire, present unique problems and require careful interpretation of the test results.

➂ For reference only.

• ASTM C 1427, Type I• MEA 6-02M

Tubolit Pipe (Tube) Insulation is an economical thermal solution from Armacell, the makers of Armaflex® and the world’s leading supplier of tubular polyethylene insulation. Self-seal versions enable faster, labor saving installation.

• Proven: Used worldwide for insulating domestic hot and cold plumbing lines.

• Economical: Cost-saving polyethylene. Tubolit White SS is a cost-competitive fiber-free 6’ alternative to 3’ fiberglass. The associated Tubolit W Tape is compatible with standard fitting covers.

• Energy efficient: Reduces heat loss and gain.• Moisture resistant: Closed cell structure prevents condensation and

wicking; no supplemental vapor retarder required.• Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOCs.

Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools.

• Quiet: Reduces plumbing noise.• Resists Mold and Mildew

Page 15: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

Armacell Product Selector | www.armacell.us | 15

Armaflex®

AdhesivesArmaflex® 520 and Armaflex 520 Black Adhesives are air-drying contact adhesives that are excellent for joining seams and butt joints of AP and NH Armaflex Pipe and Sheet Insulation and Tubolit Pipe Insulation. Where a low V.O.C. adhesive is required, use Armaflex 520 BLV Adhesive.

520 Adhesives meet MIL-A-24179A and Amend-2 as Type II, Class 1. 520 Adhesives when dried to a film meet codes and specifications of less than 25 for flame spread and less than 50 for smoke (ASTM E 84).

Armaflex Low VOC Spray Contact Adhesive, green in color, is supplied in 27 pound aerosolized canisters. The product contains no chlorinated solvents such as methylene chloride and does not contain ozone depleting compounds. Complies with SCAQMD rule 1168 for volatile organic compound content less than <5 g/l. Dried film meets the fire building codes of flame spread index of less than 25 and smoke developed index of less than 50. Excellent for bonding Armaflex sheet and roll insulations to vessels, tanks, ducts and mechanical equipment operating at temperatures below 180°F (82°C).

Armaflex®

WB FinishArmaflex WB Finish is a white water-based latex enamel for use over all forms of Armaflex insulations. It provides a protective semi-gloss finish for both indoor and outdoor applications. Armaflex WB Finish brushes or rolls on easily. Its water base formulation makes it fast-drying without solvent fumes. Cleans up with soap and warm water. Armaflex WB Finish is supplied in gallon and quart containers.

Impervious to moisture. Outdoors, is exceptionally durable and weather resistant to ultraviolet (UV) and ozone. Outdoor surfaces should be recoated every 2-4 years.

Armafix IPH, NPH Pipe Hangers

Armafix is used to support Armaflex and Armaflex NH (nonhaogen)insulated pipes with pre-insulated hangers that retard heat gain and control condensation drip from chilled-water and refrigeration systems. See Armafix Submittal Sheet for details.

Armacell Fabricated FittingsArmacell Fabricated Fittings are made-to-order and prefabricated using the world’s highest quality, closed cell insulation. Available in wall thicknesses up to 2”, these fittings are labor saving, easy to work with and apply, and provide total Armaflex system integrity.Options include 90-degree elbows (2-piece and 3-piece), T’s, 45-degree elbows, grooved fittings (AP Armaflex black) and grooved couplings

Insulation TapeAP Armaflex® Insulation Tape is made of high-quality AP Armaflex insulation. Available in tape dispenser form, the expanded closed-cell structure makes it an efficient insulation. Made with Microban® antimicrobial product protection, our tape is also formaldehyde free, low VOCs, fiber free, dust free and resists mold and mildew.

Provides a fast, easy method for insulating pipes and fittings. Reduces heat loss when applied to hot-water lines that operate up to 180°F (82°C). AP Armaflex Tape may be used with AP Armaflex Pipe and Sheet Insulation.

Insulation Products for Mechanical Systems

Page 16: Armacell Product Selection GuideFile/ArmacellProductSelectionGuide.2011.pdf · Armacell Product Selection Guide advanced insulation. 2 | Armacell Product Selector | Application REFRIGERATION,

The Armacell Advantage

MICROBAN is a registered trademark of Microban Products Company. The GREENGUARD INDOOR AIR QUALITY CERTIFIED Mark is a registered certification mark used under license through the GREENGUARD Environmental Institute.

04 11 NA NA

a d v a n c e d i n s u l a t i o n

© 2011 Armacell LLC Printed in United States of America

ARMACELL LLC7600 Oakwood Street ExtensionMebane, NC 27302

TEL: 1 800 866-5638FAX: 919 304-3847E-MAIL: [email protected]: www.armacell.us

Building Relationships That Endure Armacell is an easy-access organization that values customers as business partners. Support is available for help with installation, clarifying technical and code compliance issues, and specification assistance.

• Customer Service: The Armacell Customer Service Team has earned a reputation as the best in our industry. Teams from manufacturing, logistics and customer service meet daily to anticipate surges in demand, monitor service levels, and promptly resolve any customer inconveniences.

• Application Assistance: Guidance and training for installers, from the experts who trained an industry.

• Technical Assistance: Expertise to help solve application problems and clarify technical and code compliance issues.

• Specification Assistance: Expertise in helping with specifications and providing the right solutions for the most demanding specification criteria.

Call 800-866-5638 8:00 a.m. – 4:30 p.m. EST M-F for assistance.

World Leader in Mechanical Insulation Armacell is the global leader in mechanical insulation and foam technologies. Armacell developed Armaflex, the world’s first elastomeric thermal insulation and continues to provide product solutions to meet the challenges of thermal efficiency, condensation control, indoor air quality, sound attenuation and long-lasting performance.

Armacell has unrivaled global capabilities bolstered by 20 manufacturing facilities in 13 countries. Globally integrated research and development allows our scientists and technicians to benchmark global practices and adapt them to either global or regional requirements, codes or specifications.