2
Local control Modular structure Binary inputs outputs Binary IP reset Main supply Analog dc inputs Voltage outputs Current outputs Low Level outputs Earthing Current Voltage Frequency Phase angle DC measurement Binary inputs Binary outputs Auxiliary DC IEC61850 GOOSE Dimension Weight Power Supply dc … 1kHz -360° - +360° ±10V, ±20mA 8; 0-400V dc or ac(peak) with adjustable threshold or potential free 8 0-300V Optional 16.5kg 110-240Vac,50-60Hz 390x287x194mm(WHD) POM2-6143 Typical Specifications 10.4 inch color LCD display 13 shortcut keys Numerical keypad Quick control keys Mouse Operation LED Alarm LED Power LED Output pause button Application Relay test: l l l l l Line protection Differential protection Directional relay Time-inversed current relay Auto-reclosing, etc Measuring and control device: l l l l Synchronizer Transducer Energy meter df/dt, etc System simulation: l l Transient, steady-state fault simulation Playback of COMTRADE format file Calibration: l l l 0.5 Class energy meter disturbance recorder indicating meters, etc External PC control l l POM2-6143: 6×15A, 4×300 POM2-3243: 3×20A, 4×300V Configuration Examples Ethernet interface Sides layout for POM2-6143 Universal Test System GPS/IRIG-B USB interface Right side view POM2-6143 Left side view l l l Revolutional modular structure design with only 4 modules. Disassembling and assembling work can be completed in less than 15 minutes. Easy local maintenance by our local agent or even by user himself. l l l l l l Quick operation and convenient button control built-in industrial mouse 10.4 inch color LCD display 20 built-in test-ready modules capable for testing all type of relays More optional test modules can be added upon user request Report can be saved to flash drive through USB port l POM2 can also be controled via PowerTest relay test software runing on external PC POM2-6143 6×15A 4×300V POM2-3243 3×20A 4×300V www.relaytest.com www.ponovo.com.cn Making your work easy is our work! POM2 Universal Test System POM2-3243 Left side view Voltage outputs Aux. dc supply Current outputs

Application - PonovoQuickTest (4V,3I) QuickTest(4V,6I) Ramp State Sequence(4V,3I) State Sequence(4V,6I) Directional Time Distance(R-X) Distance(Z-Phi) Differential (3I) Differential(6I)

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Application - PonovoQuickTest (4V,3I) QuickTest(4V,6I) Ramp State Sequence(4V,3I) State Sequence(4V,6I) Directional Time Distance(R-X) Distance(Z-Phi) Differential (3I) Differential(6I)

Local control

Modular structure

Binary inputs

outputsBinary

IP reset

Main supply

Analog dc inputs Voltage outputs

Current outputs

Low Level outputsEarthing

Current

Voltage

Frequency

Phase angle

DC measurement

Binary inputs

Binary outputs

Auxiliary DC

IEC61850 GOOSE

Dimension

Weight

Power Supply

dc … 1kHz

-360° - +360°

±10V, ±20mA

8; 0-400V dc or ac(peak) with adjustable threshold or potential free

8

0-300V

Optional

16.5kg

110-240Vac,50-60Hz

390x287x194mm(WHD)

POM2-6143 Typical Specifications

10.4 inch color LCD display 13 shortcut keys Numerical keypad

Quick control keys

Mouse

Operation LED

Alarm LED

Power LED

Output pause button

Application

Relay test:

l

l

l

l

l

Line protection

Differential protection

Directional relay

Time-inversed current relay

Auto-reclosing, etc

Measuring and control device:

l

l

l

l

Synchronizer

Transducer

Energy meter

df/dt, etc

System simulation:

l

l

Transient, steady-state fault simulation

Playback of COMTRADE format file

Calibration:

l

l

l

0.5 Class energy meter

disturbance recorder

indicating meters, etc

External PC control

l

l

POM2-6143: 6×15A, 4×300

POM2-3243: 3×20A, 4×300V

Configuration Examples

Ethernet interface

Sides layout for POM2-6143 Universal Test System

GPS/IRIG-B

USB interface

Rig

ht sid

e v

iew

PO

M2

-61

43 L

eft

sid

e v

iew

l

l

l

Revolutional modular structure design with only 4 modules.

Disassembling and assembling work can be completed in less than 15 minutes.

Easy local maintenance by our local agent or even by user himself.

l

l

l

l

l

l

Quick operation and convenient button control

built-in industrial mouse

10.4 inch color LCD display

20 built-in test-ready modules capable for testing all type of relays

More optional test modules can be added upon user request

Report can be saved to flash drive through USB port

l POM2 can also be controled via PowerTest relay test software runing on external PC

POM2-6143

6×15A

4×300V

POM2-3243

3×20A

4×300V

www.relaytest.com www.ponovo.com.cn

Making your work easy is our work!

POM2 Universal Test System

PO

M2

-32

43 L

eft

sid

e v

iew

Voltage outputs

Aux. dc supplyCurrent outputs

Page 2: Application - PonovoQuickTest (4V,3I) QuickTest(4V,6I) Ramp State Sequence(4V,3I) State Sequence(4V,6I) Directional Time Distance(R-X) Distance(Z-Phi) Differential (3I) Differential(6I)

l

l

l

l

Modular software design, easy to build comprehensive test plan

More than 50 modules to meet various test requirment

Can work with flexible relay test templates to improve efficiency and save time

Compatible with Windows 10, Windows 7, Windows 2000

test-ready

Manually or automatically control over 4 voltage and 3 current sources

Manually or automatically control over 4 voltage and 6 current sources

Realize the ramping for different quantities in 3 current mode

Flexible edit of test sequences in 3 current and 4 voltage mode

Flexible edit of test sequences in 6 current and 4 voltage mode

Check directional Relay

Check the tripping time

Check zone settings of impedance relay

Check zone settings of impedance relay

Check IR/ID characteristic of different relay with 3 currents

Check IR/ID characteristic of different relay with 6 currents

Check time inversed current relay based on IEC standard

Check under frequency relay

Edit harmonic components to the output

Check Auto-reclosing function

Play back COMTRADE format file

Check ac type auxiliary relay and time relay

Check dc type auxiliary relay and time relay

Check voltage relay

(R-X)

(Z-Phi)

QuickTest (4V,3I)

QuickTest(4V,6I)

Ramp

State Sequence(4V,3I)

State Sequence(4V,6I)

Directional

Time

Distance(R-X)

Distance(Z-Phi)

Differential (3I)

Differential(6I)

Time Inversed Current

Frequency Relay

Harmonic

Auto-Reclosing

TransPlay(4V,3I)

U,I,T Relay (DC)

U,I,T Relay (AC)

Voltage Relay

Description

Local control test modules for POM2 series

PowerTest Relay Test Software

Module

PO

M2

-32

43

-

-

PO

M2

-61

43

√ √

POM2 Universal Test System POM2Universal Test System PONOVO POWER CO., LTD.

www.relaytest.com

[email protected]@relaytest.com

-