APC InfraStruXure Solution Overview
We’re waiting for your call or email. 800-222-1440 [email protected]
• Wiring Closets (1 – 3 Racks) • Small Server Rooms (1 – 5 Racks) • Small Data Centers (5 – 20 Racks) • Medium Data Centers (20 – 100 Racks) • Large Data Centers (> 100 Racks) • High Density Cooling
1
3
4
h e a t r e m o v e d f r o m t h e r o o m i s e x h a u s t e di n t o c e i l i n g t h r o u g h d u c t sC O M P O N E N T S
“One of the goals of the new building was to consolidate the networks from the existing threebuildings under one roof. This new facility operates on the Cisco Added Solution Voice Over IParchitecture for video, voice, and integrated data, providing network connectivity throughout thefacility. As IT Director, my imperative was to find a watertight solution that would protect ourcommunications infrastructure by guaranteeing uninterrupted power.”
“With InfraStruXure™, I know that no matter what happens, power flow won't be interrupted.
I don't waste time wondering about how many circuits I need to set aside for the panel, or if I needa circuit breaker in the panel. I know InfraStruXure is running behind the scenes, protecting my
equipment, my company, and allowing us to communicate with our customers.”
Because InfraStruXure™ architecture is easy to customize using standardized components, configurations may vary. Here are five
typical InfraStruXure configurations for different size installations. To configure the right InfraStruXure for you, go to page 20.
Industry: Furniture Manufacturing Application: Voice Over IP
Smart-UPS®
Smart-UPS® RT (not shown)
Symmetra® LX (not shown)
P O W E R
Markus M. Hill Director of Technology and Information Services Brayton International
1
INFRASTRUXURE FOR WIRING CLOSETS [ 1 – 3 RACKS ]
2
NetShelter® 2-post OpenFrame Racks
NetShelter® 4-Post OpenFrame Racks (not shown)
Rack PDU (Basic,Metered, and Switched)(not shown)
Rack Accessories (not shown)
NetworkAIR™ PA4000
UPS NetworkManagement Card
EnvironmentalMonitoring Unit (not shown)
R A C K2
C O O L I N G3
M A N A G E M E N T4
S E R V I C EA full range of system- and component-level servicesare available
WIRING CLOSET [ 1-3 RACKS ]
COMPUTER ROOMS[ 1-5 RACKS ]
SMALL DATA CENTERS[ 5-20 RACKS ]
MEDIUM DATA CENTERS[ 20-100 RACKS ]
LARGE DATA CENTERS[ >100 RACKS ]
1
1
2
2
2
5
TYPICAL CONFIGURATIONS
INFRASTRUXURE FOR COMPUTER ROOMS [ 1 – 5 RACKS ]
1
2
4
a i r cond i t i on ing f r om ou ts ide the room i s used to supp lementcoo l i ng w i th in t he room
power routing data routing cold air hot air
"During our four years of operation, we have experienced phenomenal growth. Our systems are critical to thesuccess of our organization. Any downtime risks our reputation."
"Our rapid growth prompted us to bring all outside services in-house, including item and core processing. We built a new operations center. During the design phase of our operations center, we recognized the need to reduce the space required for our systems and we had to pull this off without compromising neatness and cable management."
"InfraStruXure™ costs less than offerings from the competition. It’s an easily managed, fully integrated power andrack solution that affords me the luxury of having to deal with only one vendor. InfraStruXure addressed thepower backup requirements for our centralized servers, and provided us with significant space savings."
Christopher Hutchinson Vice President of Operations First Reliance Bank
Industry: Banking Application: Server Consolidation
LEGEND
P O W E R1
R A C K2
3
5
C O O L I N G M A N A G E M E N T S E R V I C E
1
NetShelter® VX Enclosure
Rack PDU (Basic,Metered, and Switched)
Rack Accessories(not shown)
Rack Air Removal Unit (ARU)
Rack Air Distribution Unit(ADU) (not shown)
NetworkAIR™ PA4000(not shown)
Door Grille Kit
Smart-UPS® (not shown)
Smart-UPS® RT (not shown)
Symmetra® LX
4
10
10
InfraStruXure™ Manager(not shown)
EnvironmentalMonitoring Unit
EnvironmentalManagement System (not shown)
10
6
10
COMPONENTS
1
3
5
5
ho t a i r f r om the rack i s pu l l ed t h rough the ARU ( ) up i n tothe ce i l i ng and re tu rned to t he a i r cond i t i on ing sys tem
4
A full range of system- and component-levelservices are available
6
Mete red Rack PDU ( ) p rov idespower d i s t r i bu t i onand a l l ows on - s i t e i ns ta l l e r s t o mon i to r t he agg rega tecu r ren t d raw
3
InfraStruXure™ 20kW UPSwith Power DistributionUnit (not shown)
Symmetra® PX 40kW UPS
InfraStruXure™ 40kWPower Distribution Unit
XR Battery Enclosure (not shown)
INFRASTRUXURE FOR SMALL DATA CENTERS [ 5 – 20 RACKS ]
1
3
"When we moved our server room to our new eighth floor location, we determined that our power protectionwas inadequate and needed to be upgraded. Initially, we had intended to purchase a generator and an exter-nal uninterruptible power supply (UPS) but we were informed that it would take almost a year to obtainone that would meet our requirements."
"We saw the InfraStruXure as a great fit for our environment. The installation went perfectly. The
components were shipped on time, we wheeled them into our server room and it only took several
hours before the system was installed and started up. The smart cable management inherent in thedesign of the InfraStruXure racks helps us to minimize the risk of human error. We no longer have to worryabout someone accidentally disconnecting the wrong cables."
"Since the power distribution is in the rack and not hard wired into the walls, if we choose to change
locations or expand, we can simply pick up and move our InfraStruXure to a new location without
losing any of our initial investment. If and when our data center load expands, we simply add another rackof properly configured power protection."
Dave Rollins Manager of Technical Services Boston Medical Center HealthNet Plan
Industry: Healthcare Application: Server Room Upgrade
COMPONENTS
P O W E R
R A C K3
C O O L I N G
M A N A G E M E N T
S E R V I C E
1
NetShelter® VX Enclosure
Rack PDU (Basic,Metered, and Switched)(not shown)
Rack Accessories(not shown)
NetworkAIR™ FM 50kW In-Row
High Density Cooling System (not shown)
Rack Air Removal Unit (ARU) (not shown)
Rack Air Distribution Unit (ADU) (not shown)
InfraStruXure™ Manager
EnvironmentalMonitoring Unit (not shown)
EnvironmentalManagement System (not shown)
2
4
2
4
A full range of system- and component-levelservices are available
1
1
3
3
4
4
4
5
4
4
Inf raStruXure ™ Manager ( ) reduces thecomplexi ty of your network-cr i t ical
physical inf rastructure by al lowing you tomanage your APC devices f rom a s ingle
console or by integrat ing into your preferred management system
5
5
“InfraStruXure™ fulfilled three core requirements for us. First, the scalability of the architecture provides us sig-
nificant flexibility in terms of power output and in terms of runtime. Second, our Video on Demand (VOD)servers are air cooled from front to back. The APC racks that house the InfraStruXure are also designed to cool
from front to back. So the same racks can effectively house our power system and our servers. Third,InfraStruXure gives us the ability to monitor our power system remotely. It provides us with battery life data,alarms, environmental monitoring data and greatly increases our ability to forecast and prevent potential failures by establishing an effective and efficient battery replacement cycle. We no longer have to deal with a single point of failure.”
“We wanted an upgradeable solution that could scale through changes and still offer us long-term value.InfraStruXure's modular approach makes it easy to upgrade anytime. With InfraStruXure's pay-as-you-growarchitecture, we haven't had to invest in more than we currently need. With InfraStruXure, I don't have to buy
a significant amount of extra equipment and horsepower upfront that I may or may not have to utilize.”
3
1
2
56
cool a i r is drawn fromthe f loor to where i t is
needed by the ADU ( )
Rich Flanders, Director of Engineering Vince Pombo, VP of Engineering (right) Time Warner Cable
P O W E R R A C K5
M A N A G E M E N T S E R V I C ENetShelter® VX Enclosure
Rack PDU (Basic,Metered, and Switched)(not shown)
Rack Accessories(not shown)
LEGEND
Symmetra® PX 80kW UPS
InfraStruXure™ 80kWPower Distribution Unit
XR Battery Enclosure
InfraStruXure™ RackDistribution Panel (not shown)
InfraStruXure™ Manager(not shown)
EnvironmentalMonitoring Unit (not shown)
EnvironmentalManagement System (not shown)
COMPONENTS
1
2
3
C O O L I N GNetworkAIR™ FM 50kW
High Density CoolingSystem (not shown)
Rack Air Removal Unit (ARU)
Rack Air Distribution Unit (ADU)
6
7
8
7
8
Industry: Communications Application: Video on Demand
8
A full range of system- and component-levelservices are available
INFRASTRUXURE FOR MEDIUM DATA CENTERS [ 20 – 100 RACKS ]
power routing RDP power feed data routing cold air hot air
4
4
5
5
5
5
4
4
Power Distribution Unit (PDU)
UPS
NetworkAIR™ FMIn-row air conditioner
pulls hot air from the backand distributes cooled air
to the front
Hot Aisle CeilingTiles/Cable Trough
Seals in hot air, preventsmixing with room air
Discharge Air PlenumDistributes cooled air to room Chamber Doors
Access to hot aisle,locks for security
HIGH DENSITY COOLING TECHNOLOGY OVERVIEW
[cold][hot]
[hot] [cold]
High Density Air Conditioning
High Density Cooling System*• Allows for quick deployment of high density
clusters
• IT equipment can be moved or changed withoutsystem reconfiguration
• Allows for changing needs and future expan-sion with a pay-as-you-grow architecture
• Sealed hot aisle eliminates mixing with coldsupply air to increase availability
• Increased cooling capacity and system efficiency from warmer air return temperatures
• UPS-supported fans through dual input powerto cooling system
Raised floor
Non-raised floor
Because most IT equipment cools fromfront to back, an optimal cooling configu-ration is that of hot-aisle, cold-aisle,where rack fronts face other rack fronts,and rack backs face other rack backs.
HOT-AISLE, COLD-AISLE
CONFIGURATION