Page 2: Altech Motor Disconnect Switches

QualityCommitmentAltech’s control components meet diverse nationaland international standards such as UL, NEC, CSA,IEC, VDE and more. Altech provides superiorcustomer service and delivery through Total QualityManagement and Continuous Process Improvement.Altech is ISO 9001 approved. We perform theseservices with honesty and integrity and are committedto achieve these goals.

Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrialcontrol components. Headquartered in Flemington, NJ, Altech has an experienced staff ofengineering, manufacturing and sales personnel to provide the highest quality products with superiorservice. This is the Altech Commitment!

With experienced Product Engineers and Customer Service personnel, Altech provides solutions toyour most pressing application challenges. All with one thought in mind - to ensure that we solveyour problem the first time!

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:11 PM Page 2

Page 3: Altech Motor Disconnect Switches

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 4

EXTENDED / DIRECT HANDLE MOTOR DISCONNECT SWITCH

KU/VKA switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5

EXTENDED / DIRECT HANDLE ACCESSORIES

Extended Handle Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7Direct Handle Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8OKA/KU Door Mounting Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9OKA Door Mounting Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10OKA/VKA Door Mounting Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

TOGGLE HANDLE MOTOR DISCONNECT SWITCH

KUE/EVA Switches and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-13

ENCLOSED MOTOR DISCONNECT SWITCHES &FUSED ENCLOSED MOTOR DISCONNECT SWITCH (30A)KEM Switches and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-15KKVM Fused Switch and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

STAINLESS STEEL ENCLOSED MOTOR DISCONNECT SWITCHESKER Switches and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-17

INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

TERMS AND CONDITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

•One of the smallest 60A switches in the industrywith compact design•Advanced switch technology (use of silver contactsensures safe and durable operation)

• Across the line, motor starting - up to 75hp/600V• General Use Rating - 16A to 150A/600V• Available as rotary switches for extended or direct handle • Toggle switches• Non-fused switch• Interrupting capacity 10kA with back-up fuse• DIN Rail and panel mount available• Comprehensive range of accessories includes

Door Mounting Kits & Fuse Holder• Snap on auxiliary contacts• Enclosed switches with NEMA Type 4X rating• Operating temperature is -20°C to +40°C

AC Motor Across-The-LineAC General Use

E185115

MOTOR DISCONNECT SWITCHES

UL508 ListedUL508 ListedManual MotorManual MotorControllersControllers

with Disconnecting Means

FEATURES AND BENEFITS:

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 3

Page 4: Altech Motor Disconnect Switches

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com4

35 m

m

74 m

m

66 m

m

58 mm15 mm15.8mm

15.8mm

73 mm 49.5 mm

35 m

m

66 m

m

74 m

m

73 mm 65 mm15.8mm

15mm

15.8mm

15.8mm58 mm

Catalog NumberNo. of PolesGeneral Purpose CurrentMaximum VoltageMotor FLA @ 480V ACMotor FLA @ 600V AC

Horsepower Rating /HP110-120V AC200V AC208V AC220-240V AC265V AC277V AC380-415V AC440-480V AC550-600V AC

Short Circuit WithstandRating at 600 V with Max. Fuse Size/Class:

K5RK5RK1J

Terminal SizeAcceptability(Cu Conductors only, 75°C)Terminal Torque

Dimensions(to convert to inches

multiply by 0.03937)

Weight

Suitable AccessoriesExtended Handle Version/Door Interlock Mechanism

ShaftHandlesAuxiliary SwitchFuse Holder

Direct Handle VersionHandle for 3 PoleHandle for 4 PoleDoor Mounting Kits

KU316N3 (4 pole - KU416N)

16A600V AC14A9A

1 Phase 3 Phase3/4 1 1/22 32 32 32 32 33 7.55 103 7.5

10kA

50A50A80A80A

14-8AWG

16 lb. in.

0.19Kg (0.419lb.) (3 pole)0.23Kg (0.507lb.) (4 pole)

L(1,2,3)00AD11-STLK10 (Y/R) UL, LK11 (Y/R) U

KU1.V, KU2.V—

K/KU3P (Y/R)K/KU4P (Y/R)

OKA/KU LK10 x; OKA x

KU325N3 (4 pole - KU425N)

25A600V AC17.5A11A

1 Phase 3 Phase1 22 52 53 7.53 7.53 7.55 107.5 155 10

10kA

50A50A80A80A

14-8AWG

16 lb. in.

0.172Kg (0.379lb.) (3 pole)0.215Kg (0.474lb.) (4 pole)

L(1,2,3)00AD11-STLK10 (Y/R) UL, LK11 (Y/R) U

KU1.V, KU2.V—

K/KU3P (Y/R)K/KU4P (Y/R)

OKA/KU LK10 x; OKA x

KU340N3 (4 pole - KU440N)

40A600V AC28A18A

1 Phase 3 Phase2 33 7.53 7.55 105 105 107.5 1510 207.5 15

10kA

50A50A80A80A

14-8AWG

16 lb. in.

0.172Kg (0.379lb.) (3 pole)0.215Kg (0.474lb.) (4 pole)

L(1,2,3)00AD11-STLK10 (Y/R) UL, LK11 (Y/R) U

KU1.V, KU2.VKV 10x38, KV 10x38 CC

K/KU3P (Y/R)K/KU4P (Y/R)

OKA/KU LK10 x; OKA x

KU363N3 (4 pole - KU463N)

60A600V AC34A27A

1 Phase 3 Phase3 55 105 105 105 107.5 1010 2015 2515 25

10kA

60A60A (80A@480V AC)

100A100A

12-4AWG

16 lb. in.

0.200Kg (0.441lb.) (3 pole)0.245Kg (0.540lb.) (4 pole)

L(1,2,3)00AD11-STLK10 (Y/R) UL, LK11 (Y/R) U

KU1.V, KU2.V—

K/KU3P (Y/R)K/KU4P (Y/R)

OKA/KU LK10 x; OKA x

3 Pole 4 Pole

4 Pole

The KU/VKA...N seriescan be used withextended and directhandles (see page 8-9for details).

Extended/Direct Handle Motor Disconnect Switch

E185115

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 4

Page 5: Altech Motor Disconnect Switches

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 5

4 Pole

82 mm

15 mm

82 m

m

79 mm69 mm

20 mm

67 mm53 mm

35 m

m

2

1

6

3 5 Ø4.5

mm

82 m

m

82 mm89 mm99 mm

20 mm

4

67 mm53 mm

15 mm

35 m

m

2

1 3

6 8

75

Ø4.5

mm

VKA380N3 (4 pole - VKA480N)

80A600V AC–47A

1 Phase 3 Phase3 7.57.5 107.5 157.5 1510 2010 2015 2520 3025 40

10kA

150A150A–

200A

4-1/0AWG

50 lb. in.

0.480Kg (1.058lb.) (3 pole)0.620Kg (1.367lb.) (4 pole)

L(1,2.3)00AD11-STLK10 (Y/R) UL, LK11 (Y/R) UVKA1.V, VKA2.V

K/VKA3-4P (Y/R)OKA/VKA x

Catalog NumberNo. of PolesGeneral Purpose CurrentMaximum VoltageMotor FLA @ 480V ACMotor FLA @ 600V AC

Horsepower Rating /HP110-120V AC200V AC208V AC220-240V AC265V AC277V AC380-415V AC440-480V AC550-600V AC

Short Circuit Withstand Rating at 600 V with Max. Fuse Size/Class:

K5RK5RK1J

Terminal SizeAcceptability(Cu Conductors only, 75°C)Terminal Torque

Dimensions(to convert to inches

multiply by 0.03937)

Weight

Suitable AccessoriesExtended Handle Version/Door Interlock MechanismShaftHandlesAuxiliary SwitchFuse Holder

Direct Handle VersionHandle for 3 & 4 PoleDoor Mounting Kits

VKA3100N3 (4 pole - VKA4100N)

100A600V AC–54A

1 Phase 3 Phase3 7.57.5 157.5 1510 2010 2010 2015 3020 4030 50

10kA

150A150A–

200A

4-1/0AWG

50 lb. in.

0.480Kg (1.058lb.) (3 pole)0.620Kg (1.367lb.) (4 pole)

L(1,2.3)00AD11-STLK10 (Y/R) UL, LK11 (Y/R) UVKA1.V, VKA2.V

K/VKA3-4P (Y/R)OKA/VKA x

VKA3125N3 (4 pole - VKA4125N)

125A600V AC–68A

1 Phase 3 Phase5 1010 2010 2015 2515 2515 3020 4025 5030 60

10kA

150A150A–

200A

4-1/0AWG

50 lb. in.

0.480Kg (1.058lb.) (3 pole)0.620Kg (1.367lb.) (4 pole)

L(1,2.3)00AD11-STLK10 (Y/R) UL, LK11 (Y/R) UVKA1.V, VKA2.V

K/VKA3-4P (Y/R)OKA/VKA x

VKA3160N3 (4 pole - VKA4160N)

150A600V AC–83A

1 Phase 3 Phase7.5 1010 2510 2515 3020 3020 3025 5030 6040 75

10kA

150A150A–

200A

4-1/0AWG

50 lb. in.

0.480Kg (1.058lb.) (3 pole)0.620Kg (1.367lb.) (4 pole)

L(1,2.3)00AD11-STLK10 (Y/R) UL, LK11 (Y/R) UVKA1.V, VKA2.V

K/VKA3-4P (Y/R)OKA/VKA x

3 Pole 4 Pole

The KU/VKA...N seriescan be used withextended and directhandles (see page 8-9for details).

Extended/Direct Handle Motor Disconnect Switch

E185115

Dimensions (to convert to inches multiply by 0.03937)

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 5

Page 6: Altech Motor Disconnect Switches

Extended/Direct HandleMotor Disconnect Switch

Auxiliary Switch

Door InterlockShaft and Nut

Panel Door

Door Interlock Handle

Xmm

cut to length

cut notch(optional)

file tip

finalproduct

8 mm

~1 mm

notchlocation& width

22.5mm Xmm 26 (±1.5)mm = 29 (±1.5)mm =

PZ01Nm Max

PZ01Nm Max

LK10Door Interlock Handle

LK11Door Interlock Handle

22.5mm

1

2

3

4

Panel Door Panel Door

ShaftLength

+ + + + ShaftLength

1/4” Padlocks1/4” Padlocks1/4” Padlocks 1/4” Padlocks1/4” Padlocks1/4” Padlocks 1/4” Padlocks1/4” Padlocks1/4” Padlocks 1/4” Padlocks1/4” Padlocks1/4” Padlocks

Example of handlewith 1/4” padlocks.

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com6

Ø79

mmØ22 mm

Panel Drilling:

3 mm

12.7

mm

38 m

m12

mm

Length

Cat. No. LK10 UL LK10 Y/R UL LK11 U LK11 Y/R UEnvironmental Rating NEMA Type 4X, IP66 NEMA Type 4X, IP66 NEMA Type 4X, IP67 NEMA Type 4X, IP67Color Black Yellow/Red Black Yellow/Red

Cat. No. L100AD11-ST L200AD11-ST L300AD11-STLength (L) 100mm 200mm 300mmMaterial Steel Steel Steel

The steel shaft ensures reliable operation even in the toughest conditions.DOOR INTERLOCK SHAFT

41 m

m4

mm

Ø40 mm

63 mm

78.5

mm

28.2

mm

28.2mm

Ø22.5 mm Ø4 mm

Extended Handle Accessories

DOOR INTERLOCK HANDLES(padlockable with up to three 1/4” padlocks)LK10 (Y/R) UL:• Single hole mounting (22.5mm)• Defeatable (built-in mechanism)LK11 (Y/R) U:• Retention mechanism (only

rotates 90° from off to on, keeps handle in off position while cabinet door is open)

• Defeatable (looses NEMA rating)

Dimensions (to convert to inches multiply by 0.03937)

E185115

DrillTemplateIncluded

DrillTemplateIncluded

SHAFT CUTTING RECOMMENDATIONSSHAFT LENGTH CUTTING GUIDLINE

Lockable with up to 3 padlocks. Lockable with up to 3 padlocks.

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 6

Page 7: Altech Motor Disconnect Switches

Kit shown; comes withswitch and fuse holder.

Kit shown; comes withKU340N and fuse holder.

FUSE HOLDER

58 mm

50 mm 70 mm

71 mm

74 mm 74 mm

56 mm 56 mm50 mm60 mm

50 mm60 mm

74 m

m

74 m

m

125

mm

125

mm

79 m

m

60 m

m

59 mm

�Ø4.

2 mm

32 mm

56 mm

58 mm

This fuseholder can beretrofitted with the KU340N.Therefore design changescan be incorporated withease to allow a fusibledisconnect.

E185115

Cat. No. KKV 332 KKV 332CC KV 10x38 KV 10x38 CCElectrical Rating 30A/600V AC 30A/600V AC 30A/600V AC 30A/600V ACFuse Type 10x38, Midget Class CC 10x38, Midget Class CCFor Use With – – KU340N KU340NKit Includes KV 10x38 / KU340N KV 10x38 CC / KU340N – –

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 7

75-220

L

93 m

m65

.5 m

m

134 mm 7 mm 38 mm 48 mm

45 m

m

Extended Handle Accessories

Cat. No. KU1.V KU2.V VKA1.V VKA2.VElectrical Rating 10A/1/2HP/125-250V AC 10A/1/2HP/125-250V AC 10A/1/2HP/125-250V AC 10A/1/2HP/125-250V ACNo. of contacts 1n.o./1n.c. 2n.o./2n.c. 1n.o./1n.c. 2n.o./2n.c.For Use With KU models KU models VKA models VKA models

Cat. No. KU3/4P VVColor Black

Cat. No. KU3/4P VV Y/RColor Yellow/Red

Cat. No. Length (L) For use withRV 66S-ST 66 mm 2x KU 3 pole (3P)RV 80S-ST 80 mm 2x KU 4P/VKA 3PRV 104S-ST 104 mm 2x VKA 4P

AUXILIARY SWITCHESThe auxiliary switchesare the snap-on typeand can be retrofitted.

Dimensions (to convert to inches multiply by 0.03937)

CHANGE-OVER KITS• For 2 KU switches• Available with black or yellow/red handle (Y/R)

PARALLEL KITS• For KU and VKA-switches• Assembly depth for KU 155-300 mm• Assembly depth for VKA 164-310 mm

Center pivoting modelavailable, contact Altech.

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 7

Page 8: Altech Motor Disconnect Switches

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com8

52 mm

74 m

m

45 m

m66

mm

45 mm 36 mm

81 mm

Cat. No. K/KU3P K/KU3P Y/RColor Black Yellow/RedFor use with KU models (3P) KU models (3P)

ALUMINUM DIN RAIL

Cat. No. RKA 3P RKA 4PFor Use With KU325/40/63N KU425/40/63N

84 mm

35 m

m

35 m

m

1 mm14 mm 14 mm

4 mm

4 mm

27 m

m

66 mm 7.5 mm

1 mm

27 m

m

7.5 mm

RKA 4PRKA 3P

NOTE:In the rare case that your mounting hardware (screws) for DIN Rail interfere with the enforcement studs in the back of the Motor DisconnectSwitch please use smaller (≤M3 or equivalent) flathead screws or change your DIN Rail to the 15mm high version.

Panel mount option for small Disconnect Switches.

74 m

m

45 m

m66

mm

45 mm 36 mm

81 mm

70 mm

95 mm

73 mm

60 mm

43 m

m

66 mm105 mm

0

1

82 m

m

45 m

m

95 mm

73 mm

60 mm

43 m

m

66 mm

Direct Handle Accessories and Mounting Alternatives

Cat. No. K/KU4P K/KU4P Y/RColor Black Yellow/RedFor use with KU models (4P) KU models (4P)

Cat. No. K/VKA3-4P K/VKA3-4P Y/RColor Black Yellow/RedFor use with VKA models (3/4P) VKA models (3/4P)

DIRECT HANDLESImproved design with metal shaft. Use for all your “insidethe panel” applications. 1 suitcase lock location.

Dimensions (to convert to inches multiply by 0.03937)

3 Pole 4 Pole

Lockable with 1 suitcase lock.

Lockable with 1 suitcase lock.

Lockable with 1 suitcase lock.

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 8

Page 9: Altech Motor Disconnect Switches

DrillTemplate &Instructions

Included

1/4” Padlocks1/4” Padlocks1/4” Padlocks

Lockable with up to 3 padlocks.

PANEL

discard

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 9

Shown with switch and display plate.(sold separately)

E185115

72 mm 38 mm Ø79 mm

OKA/KU Door Mounting Kit for KU Switches

Environmental ratings: NEMA Type 4X, IP66; 3 padlock locations.

Cat. No. (Black Handle) Cat. No. (Yellow/Red Handle) No. of aux. switches For use with OKA/KU LK10 OKA/KU LK10 Y/R 0 3 Pole KU switchOKA/KU LK10 1.V OKA/KU LK10 1.V Y/R 1 3 Pole KU switchOKA/KU LK10 2.V OKA/KU LK10 2.V Y/R 2 3 Pole KU switchOKA/KU4P LK10 OKA/KU4P LK10 Y/R 0 4 Pole KU switchOKA/KU4P LK10 1.V OKA/KU4P LK10 1.V Y/R 1 4 Pole KU switchOKA/KU4P LK10 2.V OKA/KU4P LK10 2.V Y/R 2 4 Pole KU switch

Designed for fast and easy assembly.

Dimensions (to convert to inches multiply by 0.03937)

Assembly Instructions

Use the enclosed drill template to prepare the door for door mounting kit assembly.Discard the switch handle on the disconnect switch and follow photo-illustration below.

Kit doesnot includedisconnectswitch.

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 9

Page 10: Altech Motor Disconnect Switches

DrillTemplate &Instructions

Included

1/4” Padlocks1/4” Padlocks1/4” Padlocks

Lockable with up to 3 padlocks.

PANEL

discard

Shown with switch and display plate.(sold separately)

72 mm 32 mm 70 mm

62 mm

66 m

m

62 m

m

OKA Door Mounting Kit for KU Switches

Environmental ratings: IP65; 3 padlock locations.

Cat. No. (Black Handle) Cat. No. (Yellow/Red Handle) No. of aux. switches For use with OKA 0.V OKA 0.V Y/R 0 3 Pole KU switchOKA 1.V OKA 1.V Y/R 1 3 Pole KU switchOKA 2.V OKA 2.V Y/R 2 3 Pole KU switch

Designed for fast and easy assembly.

Dimensions (to convert to inches multiply by 0.03937)

Assembly Instructions

Use the enclosed drill template to prepare the door for door mounting kit assembly.Discard the switch handle on the disconnect switch and follow photo-illustration below.

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com10

Kit doesnot includedisconnectswitch.

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 10

Page 11: Altech Motor Disconnect Switches

DrillTemplate &Instructions

Included

1/4” Padlocks1/4” Padlocks1/4” Padlocks

Lockable with up to 3 padlocks.

PANEL

Shown with switch.(sold separately)

E185115

OFF

ON

63mm

78.7

mm

82mm

87mm 41mm

OKA/VKA Door Mounting Kit for VKA Switches

Environmental ratings: NEMA Type 4X, IP66; 3 padlock locations.

Cat. No. (Black Handle) Cat. No. (Yellow/Red Handle) No. of aux. switches For use with OKA/VKA 0.V OKA/VKA 0.V Y/R 0 3 Pole VKA switchOKA/VKA 1.V OKA/VKA 1.V Y/R 1 3 Pole VKA switchOKA/VKA 2.V OKA/VKA 2.V Y/R 2 3 Pole VKA switchOKA/VKA4P 0.V OKA/VKA4P 0.V Y/R 0 4 Pole VKA switchOKA/VKA4P 1.V OKA/VKA4P 1.V Y/R 1 4 Pole VKA switchOKA/VKA4P 2.V OKA/VKA4P 2.V Y/R 2 4 Pole VKA switch

Designed for fast and easy assembly.

Dimensions (to convert to inches multiply by 0.03937)

Assembly Instructions

Use the enclosed drill template to prepare the door for door mounting kit assembly.Discard the switch handle on the disconnect switch and follow illustration below.

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 11

Kit doesnot includedisconnectswitch.

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 11

Page 12: Altech Motor Disconnect Switches

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com12

1L1 1L1

1L1 1L1 1L1

50.5 mm 71 mm

74 m

m

Catalog NumberNo. of PolesGeneral Purpose CurrentMaximum VoltageMotor FLA @ 480V ACMotor FLA @ 600V AC

Horsepower Rating /HP110-120V AC200V AC208V AC220-240V AC265V AC277V AC380-415V AC440-480V AC550-600V AC

Short Circuit Withstand Rating at 600 V with Max. Fuse Size/Class:

K5RK5RK1J

Terminal Size Acceptability(Cu Conductors only, 75°C)

Terminal Torque

Dimensions(to convert to inches

multiply by 0.03937)

Weight

Suitable AccessoriesCover Plate

The KUE series onlyrequires an additionalcover plate (see below)which makes the switchIP20 touch proof.

KUE325325A

600V AC17.5A11A

1 Phase 3 Phase1 22 52 53 7.53 7.53 7.55 107.5 155 10

10kA

50A50A80A80A

14-8AWG

16 lb. in.

0.172Kg (0.379lb.)

KUE316316A

600V AC14A9A

1 Phase 3 Phase3/4 1 1/22 32 32 32 32 33 7.55 103 7.5

10kA

50A50A80A80A

14-8AWG

16 lb. in.

0.19Kg (0.419lb.)

KUE340340A

600V AC28A18A

1 Phase 3 Phase2 33 7.53 7.55 105 105 107.5 1510 207.5 15

10kA

50A50A80A80A

14-8AWG

16 lb. in.

0.172Kg (0.379lb.)

KUE363360A

600V AC34A27A

1 Phase 3 Phase3 55 105 105 105 107.5 1010 2015 2515 25

10kA

60A60A (80A@480V AC)

100A100A

12-4AWG

16 lb. in.

0.200Kg (0.441lb.)

Toggle Handle Motor Disconnect Switch

Cat. No. K/KUE K/KUE Y R/KUE R/KUE YColor Grey Yellow Grey YellowShape Rectangular Rectangular Circular Circular

E185115

Dimensions (to convert to inches multiply by 0.03937)

Lockable with 1 padlock. Lockable with 1 padlock. Lockable with 1 padlock. Lockable with 1 padlock.

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 12

Page 13: Altech Motor Disconnect Switches

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 13

79 mm78 mm

53 mm69 mm47 mm

82 m

m

35 m

m

�4.5

mm

EVA380 + K/EVAEVA380 + K/EVA Y/R

380A

600V AC—47A

1 Phase 3 Phase3 7.57.5 107.5 157.5 1510 2010 2015 2520 3025 40

10kA

150A150A—200A

4-1/0AWG

50 lb. in.

0.480Kg (1.058lb.) (3 pole)

White Cover/ White HandleYellow Cover/ Red Handle

No. of PolesGeneral Purpose CurrentMaximum VoltageMotor FLA @ 480V ACMotor FLA @ 600V AC

Horsepower Rating /HP110-120V AC200V AC208V AC220-240V AC265V AC277V AC380-415V AC440-480V AC550-600V AC

Short Circuit Withstand Rating at 600 V with Max. Fuse Size/Class:

K5RK5RK1J

Terminal Size Acceptability(Cu Conductors only, 75°C)

Terminal Torque

Dimensions(to convert to inches

multiply by 0.03937)

Weight

Special Black Toggle Handle Motor Disconnect SwitchEVA3100 + K/EVAB

Catalog NumberEVA3100 + K/EVAEVA3100 + K/EVA Y/R

3100A600V AC–54A

1 Phase 3 Phase3 7.57.5 157.5 1510 2010 2010 2015 3020 4030 50

10kA

150A150A–

200A

4-1/0AWG

50 lb. in.

0.480Kg (1.058lb.) (3 pole)

EVA3125 + K/EVAEVA3125 + K/EVA Y/R

3125A600V AC–68A

1 Phase 3 Phase5 1010 2010 2015 2515 2515 3020 4025 5030 60

10kA

150A150A–

200A

4-1/0AWG

50 lb. in.

0.480Kg (1.058lb.) (3 pole)

EVA3160 + K/EVAEVA3160 + K/EVA Y/R

3150A600V AC–83A

1 Phase 3 Phase7.5 1010 2510 2515 3020 3020 3025 5030 6040 75

10kA

150A150A–

200A

4-1/0AWG

50 lb. in.

0.480Kg (1.058lb.) (3 pole)

Toggle Handle Motor Disconnect Switch

E185115

The EVA seriesincludes a cover plate.

Dimensions (to convert to inches multiply by 0.03937)

Lockable with 1 padlock. Lockable with 1 padlock. Lockable with 1 padlock. Lockable with 1 padlock.

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 13

Page 14: Altech Motor Disconnect Switches

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com14

Black HandleYellow/ Red Handle

No. of PolesGeneral Purpose CurrentMaximum VoltageMotor FLA @ 480V ACMotor FLA @ 600V AC

Horsepower Rating /HP110-120V AC200V AC208V AC220-240V AC265V AC277V AC380-415V AC440-480V AC550-600V AC

Short Circuit Withstand Rating at 600 V with Max. Fuse Size/Class:

K5RK5RK1J

Terminal Size Acceptability(Cu Conductors only, 75°C)

Terminal TorqueEnvironmental RatingEnclosure Type Used

Dimensions

Weight

Suitable AccessoriesAuxiliary Contacts

KEM325ULKEM325UL Y/R

3 (4 pole - KEM425UL Y/R)25A

600V AC17.5A11A

1 Phase 3 Phase1 22 52 53 7.53 7.53 7.55 107.5 155 10

10kA

50A50A80A80A

14-8AWG

16 lb. in.NEMA Type 4X

U2

0.49kg (1.08 lb.)

KU1.V, KU2.V

KEM340ULKEM340UL Y/R

3 (4 pole - KEM440UL Y/R)40A

600V AC28A18A

1 Phase 3 Phase2 33 7.53 7.55 105 105 107.5 1510 207.5 15

10kA

50A50A80A80A

14-8AWG

16 lb. in.NEMA Type 4X

U3

0.72kg (1.587 lb.)

KU1.V, KU2.V

KEM360ULKEM360UL Y/R

3 (4 pole - KEM460UL Y/R)60A

600V AC34A27A

1 Phase 3 Phase3 55 105 105 105 107.5 1010 2015 2515 25

10kA

60A60A (80A@480V AC)100A100A

12-4AWG

16 lb. in.NEMA Type 4X

U3

0.773kg (1.698 lb.)

KU1.V, KU2.V

KEM380ULKEM380UL Y/R

3 (4 pole - KEM480UL Y/R)80A

600V AC–47A

1 Phase 3 Phase3 7.57.5 107.5 157.5 1510 2010 2015 2520 3025 40

10kA

150A150A—200A

4-1/0AWG

50 lb. in.NEMA Type 4X

U3

1.021kg (2.249 lb.)

VKA1.V, VKA2.V

These enclosedswitches can be usedlocally at the motor.

Catalog Number

Polycarbonate Enclosed Motor Disconnect Switch

(to convert to inchesmultiply by 0.03937)

U3U2

96.4 mm 106 mm

Accesos (opcionales)Ø20/25

84 mm

118

mm13

0.4

mm

131 mm96 mm

144 mm132 mm

Accesos (opcionales)Ø25/32

Ø20

178

mm

190

mm

E185115

*16A model also available, please contact Altech.

*

Dimensions (to convert to inches multiply by 0.03937)

1/4” Padlocks1/4” Padlocks1/4” Padlocks

Lockable with up to 3 padlocks.

1/4” Padlocks1/4” Padlocks1/4” Padlocks

Lockable with up to 3 padlocks.

1/4” Padlocks1/4” Padlocks1/4” Padlocks

Lockable with up to 3 padlocks.

1/4” Padlocks1/4” Padlocks1/4” Padlocks

Lockable with up to 3 padlocks.

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 14

Page 15: Altech Motor Disconnect Switches

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 15

FUSED

KEM3100LKEM3100L Y/R

3 (4 pole - KEM4100L Y/R)100A600V AC–54A

1 Phase 3 Phase3 7.57.5 157.5 1510 2010 2010 2015 3020 4030 50

10kA

150A150A–

200A

4-1/0AWG

50 lb. in.NEMA Type 4X

MF10

1.9051kg (4.2 lb.)

VKA1.V, VKA2.V

KEM3125LKEM3125L Y/R

3 (4 pole - KEM4125L Y/R)125A600V AC–68A

1 Phase 3 Phase5 1010 2010 2015 2515 2515 3020 4030 5030 60

10kA

150A150A–

200A

4-1/0AWG

50 lb. in.NEMA Type 4X

MF10

1.9051kg (4.2 lb.)

VKA1.V, VKA2.V

KEM3150LKEM3150L Y/R

3 (4 pole - KEM4150L Y/R)150A600V AC–83A

1 Phase 3 Phase7.5 1010 2510 2515 3020 3020 3025 5030 6040 75

10kA

150A150A–

200A

4-1/0AWG

50 lb. in.NEMA Type 4XMF11UL

2.8351kg (6.25 lb.)

VKA1.V, VKA2.V

Enclosed Motor Disconnect Switch

KKVM332, KKVM332CCKKVM332 Y/R, KKVM332CC Y/R

330A

600V AC

10kA

50A50A80A80A

14-8AWG

16 lb. in.NEMA Type 4X

U3

0.998kg (2.2 lb.)

KU1.V, KU2.V

278

mm

183 mm

188 mm

172

mm

273

mm

172

mm

278 mm

273 mm

378

mm

373

mm

354

mm

254 mm

130

mmMF10 MF11UL U3

Cat. No. Fuse Type

KKVM 332 (Y/R) 10x38,Midget

KKVM 332CC (Y/R) Class CC

131 mm96 mm

144 mm132 mm

KNOCK-OUTSØ25/32

Ø20

178

mm19

0 mm

Dimensions (to convert to inches multiply by 0.03937)

1/4” Padlocks1/4” Padlocks1/4” Padlocks

Lockable with up to 3 padlocks.

1/4” Padlocks1/4” Padlocks1/4” Padlocks

Lockable with up to 3 padlocks.

1/4” Padlocks1/4” Padlocks1/4” Padlocks

Lockable with up to 3 padlocks.

1/4” Padlocks1/4” Padlocks1/4” Padlocks

Lockable with up to 3 padlocks.

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 15

Page 16: Altech Motor Disconnect Switches

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com16

Black HandleYellow/ Red Handle

No. of PolesGeneral Purpose CurrentMaximum VoltageMotor FLA @ 480V ACMotor FLA @ 600V AC

Horsepower Rating /HP110-120V AC200V AC208V AC220-240V AC265V AC277V AC380-415V AC440-480V AC550-600V AC

Short Circuit Withstand Rating at 600 Vwith Max. Fuse Size/Class:

K5RK5RK1J

Terminal Size Acceptability(Cu Conductors only, 75°C)

Terminal TorqueEnvironmental RatingEnclosure Type Used

Dimensions

Weight

Suitable AccessoriesAuxiliary Contacts

KER325ULKER325UL Y/R

3 (4 pole - KER425UL Y/R)25A

600V AC17.5A11A

1 Phase 3 Phase1 22 52 53 7.53 7.53 7.55 107.5 155 10

10kA

50A50A80A80A

14-8AWG

16 lb. in.NEMA Type 4X

H23

1.35kg (2.98 lb.)

KU1.V, KU2.V

KER340ULKER340UL Y/R

3 (4 pole - KER440UL Y/R)40A

600V AC28A18A

1 Phase 3 Phase2 33 7.53 7.55 105 105 107.5 1510 207.5 15

10kA

50A50A80A80A

14-8AWG

16 lb. in.NEMA Type 4X

H23

1.35kg (2.98 lb.)

KU1.V, KU2.V

These NEMA Type 4x tested enclosuresare ideal where chemicals are used forcleaning and maintenance such as foodprocessing plants and breweries.Mining is another application area.Their stainless steel construction isextremely resistant to corrosion, andthe enclosure is also rated to IP66.

Catalog Number

Stainless Steel Enclosed Motor Disconnect SwitchE185115

(to convert to inchesmultiply by 0.03937)

OFF

ON

120 mm

108 mm

180

mm

160

mm

73 mm99 mm

H23

*

* 16A model also available, please contact Altech. Dimensions (to convert to inches multiply by 0.03937)

1/4” Padlocks1/4” Padlocks1/4” Padlocks 1/4” Padlocks1/4” Padlocks1/4” Padlocks

Lockable with up to 3 padlocks. Lockable with up to 3 padlocks.

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 16

Page 17: Altech Motor Disconnect Switches

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 17

KER3100ULKER3100UL Y/R

3 (4 pole - KER4100UL Y/R)100A600V AC–54A

1 Phase 3 Phase3 7.57.5 157.5 1510 2010 2010 2015 3020 4030 50

10kA

150A150A–

200A

4-1/0AWG

50 lb. in.NEMA Type 4X

H32

2.66kg (5.87 lb.)

VKA1.V, VKA2.V

KER3125ULKER3125UL Y/R

3 (4 pole - KER4125UL Y/R)125A600V AC–68A

1 Phase 3 Phase5 1010 2010 2015 2515 2515 3020 4030 5030 60

10kA

150A150A–

200A

4-1/0AWG

50 lb. in.NEMA Type 4X

H32

2.66kg (5.87 lb.)

VKA1.V, VKA2.V

Stainless Steel Enclosed Motor Disconnect Switch

KER360ULKER360UL Y/R

3 (4 pole - KER460UL Y/R)60A

600V AC34A27A

1 Phase 3 Phase3 55 105 105 105 107.5 1010 2015 2515 25

10kA

60A60A (80A@480V AC)

100A100A

12-4AWG

16 lb. in.NEMA Type 4X

H32

2.66kg (5.87 lb.)

KU1.V, KU2.V

KER380ULKER380UL Y/R

3 (4 pole - KER480UL Y/R)80A

600V AC–47A

1 Phase 3 Phase3 7.57.5 107.5 157.5 1510 2010 2015 2520 3025 40

10kA

150A150A—200A

4-1/0AWG

50 lb. in.NEMA Type 4X

H32

2.66kg (5.87 lb.)

VKA1.V, VKA2.V

E185115

ON

OFF

160 mm

125 mm90 mm139 mm

280

mm

260

mm

H32

Dimensions (to convert to inches multiply by 0.03937)

1/4” Padlocks1/4” Padlocks1/4” Padlocks 1/4” Padlocks1/4” Padlocks1/4” Padlocks 1/4” Padlocks1/4” Padlocks1/4” Padlocks 1/4” Padlocks1/4” Padlocks1/4” Padlocks

Lockable with up to 3 padlocks. Lockable with up to 3 padlocks. Lockable with up to 3 padlocks. Lockable with up to 3 padlocks.

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 17

Page 18: Altech Motor Disconnect Switches

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com18

Motor Disconnect Switch Index

EVA3100 + K/EVA ...........................................................13EVA3100 + K/EVA Y/R ....................................................13EVA3100 + K/EVAB.........................................................13EVA3125 + K/EVA ...........................................................13EVA3125 + K/EVA Y/R ....................................................13EVA3160 + K/EVA ...........................................................13EVA3160 + K/EVA Y/R ....................................................13EVA380 + K/EVA .............................................................13EVA380 + K/EVA Y/R ......................................................13K/KU3P..............................................................................8K/KU3P Y/R .......................................................................8K/KU4P..............................................................................8K/KU4P Y/R .......................................................................8K/VKA3-4P ........................................................................8K/VKA3-4P Y/R..................................................................8KEM3100L.......................................................................15KEM3100L Y/R ................................................................15KEM3125L.......................................................................15KEM3125L Y/R ................................................................15KEM3150L.......................................................................15KEM3150L Y/R ................................................................15KEM325UL ......................................................................14KEM325UL Y/R ...............................................................14KEM340UL ......................................................................14KEM340UL Y/R ...............................................................14KEM360UL ......................................................................14KEM360UL Y/R ...............................................................14KEM380UL ......................................................................14KEM380UL Y/R ...............................................................14KEM4100L Y/R ................................................................15KEM4125L Y/R ................................................................15KEM4150L Y/R ................................................................15KEM425UL Y/R ...............................................................14KEM440UL Y/R ...............................................................14KEM460UL Y/R ...............................................................14KEM480UL Y/R ...............................................................14KER3100UL.....................................................................17KER3100UL Y/R..............................................................17KER3125UL.....................................................................17KER3125UL Y/R..............................................................17KER325UL.......................................................................16KER325UL Y/R................................................................16KER340UL.......................................................................16KER340UL Y/R................................................................16KER360UL.......................................................................17KER360UL Y/R................................................................17KER380UL.......................................................................17KER380UL Y/R................................................................17KER4100UL Y/R..............................................................17KER4125UL Y/R..............................................................17KER425UL Y/R................................................................16KER440UL Y/R................................................................16KER460UL Y/R................................................................17KER480UL Y/R................................................................17KKV 332 ............................................................................7KKV 332CC .......................................................................7KKVM332 ........................................................................15KKVM332 Y/R..................................................................15KKVM332CC ...................................................................15KKVM332CC Y/R ............................................................15KU1.V ................................................................................7KU2.V ................................................................................7KU3/4P VV ........................................................................7KU3/4P VV Y/R..................................................................7KU316N.............................................................................4KU325N.............................................................................4KU340N.............................................................................4KU340N.............................................................................4

KU363N.............................................................................4KU363N.............................................................................4KU416N.............................................................................4KU425N.............................................................................4KUE316 ...........................................................................12KUE325 ...........................................................................12KUE340 ...........................................................................12KUE363 ...........................................................................12KV 10x38...........................................................................7KV 10x38 CC.....................................................................7L100AD11-ST....................................................................6L200AD11-ST....................................................................6L300AD11-ST....................................................................6LK10 UL ............................................................................6LK10 Y/R UL......................................................................6LK11 U ..............................................................................6LK11 Y/R U........................................................................6OKA 0.V ..........................................................................10OKA 0.V Y/R....................................................................10OKA 1.V ..........................................................................10OKA 1.V Y/R....................................................................10OKA 2.V ..........................................................................10OKA 2.V Y/R....................................................................10OKA/KU LK10 ...................................................................9OKA/KU LK10 1.V .............................................................9OKA/KU LK10 1.V Y/R ......................................................9OKA/KU LK10 2.V .............................................................9OKA/KU LK10 2.V Y/R ......................................................9OKA/KU LK10 Y/R.............................................................9OKA/KU4P LK10 ...............................................................9OKA/KU4P LK10 1.V.........................................................9OKA/KU4P LK10 1.V Y/R..................................................9OKA/KU4P LK10 2.V.........................................................9OKA/KU4P LK10 2.V Y/R..................................................9OKA/KU4P LK10 Y/R ........................................................9OKA/VKA 0.V ..................................................................11OKA/VKA 0.V Y/R ...........................................................11OKA/VKA 1.V ..................................................................11OKA/VKA 1.V Y/R ...........................................................11OKA/VKA 2.V ..................................................................11OKA/VKA 2.V Y/R ...........................................................11OKA/VKA4P 2.V.............................................................11OKA/VKA4P 0.V..............................................................11OKA/VKA4P 0.V Y/R .......................................................11OKA/VKA4P 1.V..............................................................11OKA/VKA4P 1.V Y/R .......................................................11OKA/VKA4P 2.V Y/R .......................................................11RKA 3P..............................................................................8RKA 4P..............................................................................8VKA1.V ..............................................................................7VKA2.V ..............................................................................7VKA3100N.........................................................................5VKA3125N.........................................................................5VKA3160N.........................................................................5VKA380N...........................................................................5VKA4100N.........................................................................5VKA4125N.........................................................................5VKA4160N.........................................................................5VKA480N...........................................................................5

Part No. Page Part No. Page

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 18

Page 19: Altech Motor Disconnect Switches

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 19

STANDARD TERMS AND CONDITIONS OF SALE

TITLE - Title to the products of ALTECH shall remain with ALTECHuntil payment is made in full by Customer. Such reservation of title is forthe purpose of securing the purchase price and shall not relieveCustomer of the duty to inspect the products upon receipt, to notifyALTECH of any deficiencies or defects, and to exercise due care in theuse, installation, operation, and maintenance of the products when onthe premise of the Customer or under the control of the Customer.Notwithstanding any reservation of title by ALTECH, risk of loss shallpass to customer at any time of shipment.

SHIPMENT AND DELIVERY - All orders for destination in the mainlandUnited States (less Hawaii, Alaska and non-continental United Statespossessions) will be shipped F.O.B. Flemington, N.J. All destination,shipping and other charges shall be paid by the Customer in accordancewith ALTECH’s then current shipping and billing practices.

Delivery dates given in the acceptance of any order are approximate.ALTECH shall not be liable for delays in delivery or in performance dueto causes beyond its reasonable control including acts of God, acts ofCustomer, acts of civil or military authority, fires, strikes or other labordisturbances, war, riot or delays in transportation. In the event of suchdelay, the date of delivery or performance shall be extended for a periodequal to the time lost by reason of the delay.

PRICE - PRICES in any ALTECH publication are subject to changewithout prior notification. Catalog prices are based on prices publishedin the current price list. All written quotations are valid for thirty (30) daysfrom the date of quotation. Customer shall pay all sales, use, excise orsimilar taxes whenever ALTECH must itself pay and/or collect such taxfrom Customer arising out of the sale.

PAYMENT - Customer agrees to make payment within thirty (30)days of date of the invoice from ALTECH. Customer agrees to pay a latepayment charge of one and one-half percent (1.5% per month, or themaximum late payment charge permitted by applicable law, whichever isless, on any unpaid amount for each calendar month (or fraction thereof)that such payment is in default. Orders amounting to less than $100.00will be billed at $100.00 plus freight. Full carton purchases are required.In the event of referral to an attorney for collection, reasonable attorney’sfees for collection of the overdue amount shall be paid by Customer. Inthe event payment is not received within 30 days from the date ofinvoice, any discount shall be cancelled and the full list price will be due.

LIMITED WARRANTY - ALTECH warrants to Customer that theequipment purchases shall be free from defects in material andworkmanship under normal use and service for a period of one yearfrom shipment.

Written notice as an explanation of the circumstances of any claimthat the equipment has proved defective in material or workmanshipshall be given promptly by the Customer to ALTECH.

ALTECH will not be liable for any misuse, improper operations,improper installation, improper maintenance, alteration, modification,accident or unusual degradation of the equipment or parts due to anunsuitable installation environment.

No representation of other affirmation of facts, including but notlimited to statements regarding capacity, suitability for use orperformance of the equipment, shall be or be deemed to be a warrantyor representation by ALTECH for any purpose, nor give rise to anyliability or obligation of ALTECH whatsoever.

Customer’s sole and exclusive remedy in the event of breach ofwarranty, as set forth herein, is expressly limited to (1) the correction ofthe defect by adjustment, repair, modification, or replacement, or (2)issuance of a credit or refund of the purchase price for the defectiveequipment at ALTECH’s election and sole expense.

EXCEPT AS SPECIFICALLY PROVIDED IN THIS AGREEMENT,THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIEDINCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES ORMERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

THIS WARRANTY EXTENDS ONLY TO THE CUSTOMER FROMALTECH OR ITS AUTHORIZED DISTRIBUTOR.

LIMITATION OF LIABILITY - IN NO EVENT, SHALL ALTECH BELIABLE FOR LOSS OF PROFITS, INDIRECT, SPECIAL,CONSEQUENTIAL OR OTHER SIMILAR DAMAGES ARISING OUT OFANY BREACH OF THIS AGREEMENT OR OBLIGATIONS UNDER THEAGREEMENT.

ALTECH SHALL NOT BE LIABLE FOR ANY DAMAGES CAUSEDBY DELAY IN SHIPMENT, INSTALLATION OR FURNISHING OFEQUIPMENT OR SERVICES UNDER THIS AGREEMENT.No action arising out of any claimed breach of this Agreement may bebrought by either party more than two (2) years after the cause of actionhas accrued.

PATENT INDEMNITY - ALTECH shall defend or settle any suit orproceeding brought against Customer based on a claim that anyequipment made to ALTECH design and furnished hereunderconstitutes an infringement of any existing United States patent,provided (ALTECH) is notified promptly in writing and is given completeauthorization and information required for the defense, and ALTECHshall pay all damages and costs awarded against Customer, but shall notbe responsible for any costs, expense or compromise incurred or madeby Customer without ALTECH’s prior written consent. If any equipmentis in ALTECH’s opinion likely to or does become the subject of a claimfor patent infringement, ALTECH may at its option and expense procurefor Customer the right to continue using the device, modify it to becomenon-infringing, but in the event ALTECH is not reasonably able to modify,substitute, or otherwise procure for Customer the right to continue usingit, ALTECH will remove such equipment and refund to Customer theamount paid in excess of a reasonable rental for past use.

ALTECH shall not be liable for any infringement or claim based uponuse of the equipment in combination with other equipment not suppliedby ALTECH or with modifications made by Customer.

The foregoing states the entire liability of ALTECH to Customerarising from patent infringement.

SELLER’S REMEDIES - Should Customer fail to make any paymentwithin ten (10) days of its due date, or fail to perform any other of theCustomer’s obligation hereunder upon thirty (30) days written notice, orshould Customer be or become insolvent or be a party to any bankruptcyreceivership proceeding prior to full payment of all amounts payablehereunder, ALTECH may: (a) with or without demand or notice tocustomer declare the entire amount unpaid immediately due andpayable; (b) enter upon the premises where the equipment may be foundand remove it (Customer shall assemble the equipment and make itavailable to ALTECH at a place reasonably convenient to both partiesand shall permit and assist ALTECH in effecting the retaking andremoval of the equipment); and (c) sell any or all the equipment aspermitted under applicable law, applying the proceeds of the sale topayment of the expenses of retaking, repairing and selling theequipment, reasonable attorney fees and to the satisfaction of allindebtedness then due and unpaid under this Agreement. Any surplusshall be paid to Customer and any deficiency shall be paid to ALTECHby Customer.

The remedies provided herein shall be cumulative and in addition toall other remedies provided by law or equity or under the UniformCommercial Code.

GOVERNING LAW - This agreement will be governed by the Lawsof the State of New Jersey.

GENERAL - This Agreement shall only become effective and bindingwhen either (a) it has been accepted and executed by an authorizedrepresentative of ALTECH, or (b) the equipment has been shipped toCustomer, with or without acceptance in writing hereon. Notice ofacceptance is hereby waived by Customer. Customer herebyacknowledges receipt of a true and complete copy hereof.

No addition to or modification of any of the Terms and Conditions ofSale as they appear herein shall be binding upon ALTECH unless signedin writing by duly authorized representative of ALTECH in Flemington,N.J.

Typographical and clerical errors in quotations, orders andacknowledgments are subject to correction.

This Agreement is not assignable without the prior written consent ofALTECH. Any attempt to assign any of the rights, duties or obligations ofthis Agreement without such consent is void.

If any provision or provisions of this Agreement shall be held to beinvalid, illegal or unenforceable, the validity, legality and enforceability, ofthe remaining provisions shall not in any way be affected or impairedthereby.

ALTECH is not responsible for failure to fulfill its obligation under thisAgreement due to causes beyond its control, or except as agreed herein.

THE CUSTOMER ACKNOWLEDGES THAT HE HAS READ THEAGREEMENT, UNDERSTANDS IT, AND AGREES TO BE BOUND BYITS TERMS AND CONDITIONS. FURTHERMORE, THE CUSTOMERAGREES THAT IT IS THE COMPLETE AND EXCLUSIVE STATEMENTOF THE AGREEMENT BETWEEN THE PARTIES, WHICHSUPERSEDES ALL PROPOSALS OR PRIOR AGREEMENTS, ORALOR WRITTEN, EXPRESSED OR IMPLIED, AND ALL OTHERCOMMUNICATIONS BETWEEN THE PARTIES RELATING TO THESUBJECT MATTER OF THIS AGREEMENT.

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 19

Page 20: Altech Motor Disconnect Switches

Altech Corporation35 Royal RoadFlemington, NJ 08822-6000Phone (908) 806-9400Fax (908) 806-9490www.altechcorp.com

Altech Corp.® 444-082011-1KBW

Disco_2011(final).QXD_Disco2006.QXD 7/22/11 4:12 PM Page 20