24
Agilent 1200 Series LC Systems and Modules

Agilent 1200 Series LC Systems and · PDF fileAgilent 1200 Series ... exploits the power of Agilent ZORBAX Rapid Resolution HT columns with 1.8 µm particles, ... column regeneration

Embed Size (px)

Citation preview

Agilent 1200 SeriesLC Systems and Modules

2

3

Agilent 1200 SeriesPure Liquid Chromatography

Agilent Technologies has taken itsworld leading LC system and made it even more flexible, smarter andultimately equipped for the future.

The new Agilent 1200 Series is finelytuned to give you a winning combinationof speed, resolution and sensitivity,while the modular design ensures that you get a configuration ideallysuited to meet your applicationrequirements.

Agilent has been developing robustand reliable LC systems for over 30 years. The Agilent 1200 Seriesrepresents the latest advance in this evolution of excellent integratedsolutions, designed to help youachieve uncompromised data quality and higher productivity.

Make a secure investment in thefuture of your lab with the scalableand open architecture of the Agilent1200 Series.

All the performance.All the time.

4

Sensitivity and PerformanceOptimized to give you complete confidence in your results

Spectral information from 190 to 950 nm

The dual-lamp design and thetemperature control of the Agilent1200 Series diode array detectorsensure outstanding sensitivity.Photodiode arrays with 1024elements, programmable slit width(1, 2, 4, 8, 16 nm) and the selectionof nine different flow cells enableoptimization of resolution, linearityand sensitivity.

The seamless integration of eachmodule gives you unparalled accuracyand precision for both quantitative andqualitative analysis. Highly sensitivedetectors deliver the lowest possibledetection limits for even the mostdemanding applications.

Revolutionary HPLC-Chip/MS integrates capillaries,nanocolumns and nanospray emitter on a single polymer chip.

Limit of detection of anthracene at different data rateswith diode array detector.

Serum sample with HPLC-Chip/6320 Ion Trap LC/MS, EIC of 311.1 →→ ΣΣ (155.9, 217.9, 245.0), 1 µL injection.

HPLC-Chip/MS for reliablehigh sensitivity nanospray

The easy-to-use HPLC-Chip/MSsystem significantly improves yournanoflow separations by eliminatingall post-column dead volumes and is ideally suited for high sensitivitynanospray LC/MS with limited sample amounts.

Mass selective detection for more confidence

By providing molecular weight and structural information, which complements the spectral informationfrom a diode array detector, the Agilent6000 Series LC/MS systems are theideal solutions for scientists who needadditional selectivity and sensitivity for their chromatographic systems.

Limit of Detection: 10 fg or 32 attomoles Sulfadimenthoxine

5

High resolution chromatographyreveals more

Small particle size and long separationcolumns are key for higher efficiencyand resolution. The Agilent 1200Series Rapid Resolution system fullyexploits the power of Agilent ZORBAXRapid Resolution HT columns with 1.8 µm particles, providing a newdimension of information for complexsamples.

Superior injection precisionand lowest carryover

The selection of different autosamplersprovides for precision levels of < 0.5 % RSD over an injection volumerange from 0.01 µL to 2000 µL. The unique flow-through design,combined with the external needlewash and optional multiple washsolvents, virtually eliminates carryover,even for highly adsorptive compounds.

High resolution chromatography of a ginseng root extract with the Agilent 1200 Series Rapid Resolution system and TOF detection,

with the average peak width of 0.13 minutes giving a peak capacity of 540.

For more information visit: www.agilent.com/chem/1200performance

Typical repeatability data for injectionvolumes demonstrates the high precision of the standard autosampler.

Injection volume [µL]

6

Speed and ThroughputModular and scalable platform lets you decide just how fast you want to work

By choosing a system from the fastquaternary/binary LC system throughto the ultra-fast rapid resolutionsystem you can achieve new levels ofproductivity, processing more samplesin less time, while maintaining andeven improving data quality.

Short columns with sub-2 µm particles offer a unique opportunity to dramatically reduce analysis time by increasing the flow rate withoutlosing separation performance. In order to take full advantage of their power, you need a system thatcan do more than handle high backpressure. The answer is a fullyintegrated solution, optimized for system volumes, cycle times,detection rates and temperaturecontrol.

Agilent 1200 Series binary pump SL

• Configurable delay volume downto 120 µL together with a flowrange up to 5 mL/min providesuniversal applicability

• Electronic damping control for lowest baseline noise

• Perfect choice for fast and precise gradients using LC/MS, as well as UV-only systems

• Fully exploits the speed andseparation potential of ZORBAXRapid Resolution HT columns

min0.1 0.2 0.3 0.4

mAU

0

50

100

150

200

250

300

350

0.08

8 -

Ace

tani

lide

0.13

9 -

Ace

toph

enon

e

0.19

6 -

Prop

ioph

enon

e

0.24

6 -

But

yrop

heno

ne

0.26

4 -

Ben

zoph

enon

e

0.29

0 -

Val

erop

heno

ne

0.33

0 -

Hex

anop

heno

ne

0.36

4 -

Hep

tano

phen

one

0.39

4 -

Oct

anop

heno

ne

PWH

H =

197

mill

isec

onds

s6 12 18 24

Ultra-fast separation of a phenonemix with the Agilent 1200 SeriesRapid Resolution system.

Column: ZORBAX SB RRHT C18, 2.1 mm x 50 mm, 1.8 µmFlow = 2.4 mL/min Gradient: water/acetonitrile0 min 35 % 0.38 min 95 %0.46 min 95 %0.47 min 35 % Temperature: 95 °C Pressure: 550 barDetection: DAD SL, 80 Hz data rate

Fast cycle time for ultra-fast analysis

• High performance autosamplersenable fast injection cycles without sacrificing lowest carryover

• Valve solutions for alternatingcolumn regeneration

• Minimized run-to-run instrumentand software initialization time

7

Peltier cooling/heating ranging from10 °C below ambient up to 100 °C.

High temperature enableshigher speed

The two independently controllablelow volume heat exchangers allow ultra-fast, high temperatureseparation with unique post-columncooling for the lowest possible UV detection limits.

Complete ZORBAX RapidResolution HT column portfolio

The optimized particle size distributionresults in less back pressure whichmakes these columns the number onechoice for all LC systems.

80 Hz full spectral sampling rateprovides resolution and peak capacitygains of 90 % relative to 10 Hzsampling rates.

Ultra-fast detectors withuncompromised sensitivity

• Programmable variable wavelengthdetector VWD (55 Hz)

• Multiple wavelength detector MWD (80 Hz)

• Diode array detector for full spectral acquisition DAD (80 Hz)

• Five types of mass spectrometers,all with fast spectral acquisitionthat can keep up with the fastestchromatography

The ChemStation explorer enables fast data review.

For more information visit: www.agilent.com/chem/1200RRHT

8

Reliability and LifetimeEasy maintenance and intelligent system monitoring for increased uptime

Robust components

• Long-life pistons and seals, together with active seal wash,reduce the frequency of preventivemaintenance

• Deuterium and xenon lamps with a lifetime of over 2000 hours

• Patented orthogonal spray designsubstantially reduces ion sourcecontamination and the need forcleaning

Easy maintenance

• Demonstration videos on a multimedia CD-ROM guide youthrough maintenance procedures

• Easily interchangeable ion sources

• E-Pac design significantly reducesassembly and disassembly time

A unique embedded data recovery card for DAD SL offers you“data-never-lost insurance”.

Agilent system intelligence

• Early Maintenance Feedback (EMF)tracks system usage (such as lampburn time, solvent usage) and alertsyou for timely replacement of parts

• Column identification module records column parameters (suchas number of injections, particlesize and maximum pressure) andprovides a unique column signature

• Patented RFID tracking technologyin the DAD SL saves all relevantmeta data from the flow cells and UV lamp

• Control Area Network (CAN) provides inter-modular, real-timecommunication for reliable operation, regardless of PC failures or network interruptions

• Software independent LC diagnostictool assists users and the supportexperts interpreting the instrumentstatus

• Agilent system intelligence provides a new generation of services withon-demand remote connectivity for a new level of productivity

Self-aligning, front access to replacement parts, such as lamp and flow cells.

With an installed base of more than60,000 LC systems, Agilent LCtechnology is renowned for itsreliability under all operatingconditions. The Agilent 1200 Seriesrepresents the next generation of LC,designed for even greater robustnessand reliability together with enhancedperformance.

Agilent pioneered technologies tomonitor and track important systemparameters with the goal of ensuringthat you achieve greater productivityand keep operating costs low.

9

Agilent intelligent services

Using the remote capabilities of yourinstrument, the latest generation of Agilent services offers real-timeinsight into instrument utilization and performance. Backed by highlyskilled Agilent service engineers and application scientists, these intelligent services provide a wholenew level of performance.

• Agilent LC diagnostics instrumentstatus report includes all importantinformation, such as system configuration, error log book, EMF and guidance report

• Maximized lab productivity – secureand streamlined communicationbetween your lab and the Agilentsupport organization

• Optimized return on instrument capital – proactively monitor instrument performance and utilization

Customer support and services

Agilent provides customer-focusedproducts and services for all stages in an instrument's life cycle, frominstallation and upgrade to operationand repair. The Agilent global networkof support services offers a broadrange of options for customized orcontract services, enabling you tochoose the package which best suitsyour laboratory needs and budgetrequirements.

At the push of a button, Agilent LC diagnostics generates complete instrument status reports in pdf format.

Intelligent ServicesGateway(s)

Collects data fromyour instruments

Dedicated Intelligent Services

Enterprise Server

Your Laboratory NetworkAgilent Support

Infrastructure

Intelligent ServicesGateway ControllerGives you complete

control of data flow andaccess privileges

For more information visit: www.agilent.com/chem/1200reliability

10

Open and OrganizedScalable and open software architecture with Agilent OL operating system

ChemStation for research andmethod development tasks

Agilent ChemStation enables you to acquire, review and organize largeamounts of data, giving you instantaccess to online instrument modifications and results. The built-inmacro language makes it easy to customize and the software supportsnumerous add-ons.

• Level 5 instrument control for yourAgilent instruments

• Built-in diagnostics, maintenanceand Early Maintenance Feedback(EMF) functions for maximumuptime

• Control of LC/MS, GC/MS, CE,CE/MS and generic A/D converters

• Add-on modules for specific solutions, such as high throughputpurification software, GPC/SEC Data Analysis, Analyst, LC/MS EasyAccess, ChemStation Data Browser

In parallel to the development ofenhanced analytical hardware, Agilent develops software solutionsdesigned to meet your specific needs. The Agilent range extends from single workstations through to client-server solutions and an innovativeinformatics framework to unite yourenterprise, ensuring that you canexpand your operations easily and effectively.

Workstation software systemsto improve your daily output

Agilent workstations give you highlevel instrument control, dataacquisition and data managementcapabilities, designed to help youincrease productivity. All softwaresystems are available with InstallationQualification (IQ) and OperationalQualification (OQ).

• Reduce training costs

• Comply with regulatory guidelines

• Extend the system as lab needs grow

• Employ sophisticated level 4 and 5 instrument control

EZChrom Elite for maximumflexibility and compliance

Agilent EZChrom Elite workstation is an easy to use software solution for labs with instruments from multiple vendors. It also provides high automation capability withadvanced “smart” sequencing andreporting capabilities with automatedspreadsheet calculations.

• Full compliance features

• Integrated multi-vendor instrumentcontrol

• Powerful and flexible reporting

• SMART sequencing for flexibleautomation tasks

• Easy scale-up from workstation to client-server system

Agilent 1200 Series instant pilot

• Cost-effective, standalone solutionfor single instrument control

• Full instrument control and displayof online signal(s), maintenance,diagnostic and Early MaintenanceFeedback (EMF) functions

• Comfortable operation in the palmof your hand or securely mountedon one of the 1200 Series modules

• Large, high-brightness coloredscreen

• USB memory stick for method and sequence storage, and transferto another 1200 system

• Intuitive software with online tip-tool and context-sensitive helpfor ease of use

Parameters can bechanged immediately

Online tip-tool shows limits instantlyfor ease of use

Color-coded information on status of 1200 Series system

Signal plot(s) can beenlarged to full screen

Easy scale-up from single workstationto enterprise-wide solutions within the Agilent OL operating systemfor the laboratory.

11

For more information visit: www.agilent.com/chem/labinformatics

Agilent OL ECM reachesbeyond the single laboratory

The Agilent OL philosophy lets youcommunicate beyond the boundariesof a single lab. By implementingAgilent OL’s core component – the Enterprise Content Managementsystem (ECM) – you can acquire andorganize your data across laboratoriesand departments.

• Saves all documentation and data in a single repository

• Organize and retrieve data using advanced search engines

• Enables several people to rapidlyand easily review a complete result set for a sample, includinggraphical results

Agilent OL enables total content management of instruments as well as general laboratory information.

Client-server systems expandyour operations

As your facility grows, EZChrom Eliteworkstations can be easily scaled upto client-server systems, enabling youto access and control your instrumentsfrom any PC within the network. If you are working in a highly regulatedenvironment, Agilent Cerity forPharmaceutical QA/QC provides full workflow support of quality control operations.

Scalable SolutionsFor future expandability and adaptability

Manual Isocratic LC SystemAutomated Quaternary LC SystemAutomated Binary LC SystemRapid Resolution LC System

HPLC-Chip/MS SystemNanoflow LC SystemCapillary LC SystemPreparative LC Systems

Pure LC

Agilent 1200 Series

12

13

14

Module Selection Guide

Thermostatted ColumnCompartmentTemperature range: 10 °C belowambient to 80 °C

Thermostatted ColumnCompartment SLTemperature range: 10 °C belowambient to 100 °C Column/Valves Organizer

Isocratic PumpFlow range: 0.001–10 mL/min*,for isocratic analysis (column ID: 2.1–9.4 mm)

Capillary PumpFlow range: 0.01–100 µL/min (extendable up to 2.5 mL/min)*,for gradient analysis (column ID: 0.18–1 mm)

Binary PumpFlow range: 0.001–5 mL/min,for fast gradient analysis (column ID: 2.1–4.6 mm)

Binary Pump SLFlow range: 0.001–5 mL/min*,for ultra-fast and high resolutiongradient and analysis (column ID: 1–4.6 mm)

Quaternary PumpFlow range: 0.001–10 mL/min*,for gradient analysis (column ID: 3–9.4 mm)

Nanoflow PumpFlow range: 0.01–1 µL/min (extendable up to 2.5 mL/min)*,for gradient analysis (column ID: 0.075–0.1 mm)

Preparative PumpFlow range: 0.001–100 mL/min (extendable to binary gradient) for isolation and purification (column ID: 4.6–50 mm)

Agilent 1200 Series column/valve organization

For more information you can downloadData Sheets from the Agilent website:www.agilent.com/chem/1200datasheets

35900 A/D Converter for non-Agilent equipment

Agilent interfaces

www.agilent.com/chem/1200pumps

Agilent 1200 Series pumping systems * settable flow range with degasser

Vacuum DegasserFlow rate: up to 10 mL/minInternal volume: 12 mL

Micro DegasserFlow rate: up to 5 mL/minInternal volume: 1 mL

Micro Collector/SpotterFlow rate: up to 100 µL/min

Fraction Collector (AS)Flow rate: up to 10 mL/min

Fraction Collector (PS)Flow rate: up to 100 mL/min

Manual InjectorsInjection range: loops for 5 µL–20 mL

Standard AutosamplerInjection range: 0.1 µL–100 µL (extendable up to 5000 µL) Sample container: vials

High Performance AutosamplerInjection range: 0.1 µL–100 µL(extendable up to 1500 µL) Sample container: vials and well-plates

High Performance Autosampler SLInjection range: 0.1 µL–100 µL(extendable up to 1500 µL) Sample container: vials and well-plates

Dual Loop Autosampler PSInjection range: up to 10 mLSample container: vials and well-plates

Micro Well-plate AutosamplerInjection range: 0.01–8 µL (extendable up 40 µL)Sample container: vials and well-plates

Preparative AutosamplerInjection range: 0.1–5000 µLSample container: vials

Thermostat for AutosamplerTemperature range: 4–40 °C

Thermostat for Fraction CollectorTemperature range: 4–40 °C

Plate Handler with automationinterface (scalable) Shallow well-plates: up to 16 (80)Deep well-plates: up to 4 (16)Vial plates: up to 6 (24)

Agilent 1200 Series degassers

Agilent 1200 Series fraction collectors

Agilent 1200 Series injection systems

www.agilent.com/chem/1200autosamplers

15

All the performance.

Multiple Wavelength Detector for multi-ë analysis 5 signals, 20 Hz data rate

Multiple Wavelength Detector SLfor ultra-fast multi-ë analysis 8 signals, 80 Hz data rate

Diode Array Detector for multi-ë and spectral analysis 5 signals, 20 Hz data rate

Fluorescence Detectorfor multi-signal detection and online fluorescence spectra

Refractive Index Detectorfor refractive index range: 1.00–1.75 calibrated

Diode Array Detector SLfor ultra-fast multi-ë and spectralanalysis, 8 signals, 80 Hz data rate

Variable Wavelength Detectorfor programmable single ë analysis,1 signal, 13 Hz data rate

Variable Wavelength Detector SLfor ultra-fast, programmable single ëanalysis, 1 signal, 55 Hz data rate

6-position selection valve 12-position/13-port valve

2-position/10-port valve 2-position/6-port micro valve2-position/10-port micro valve 2-position/6-port valve

Agilent 1200 Series Instant Pilot Agilent Workstations andChromatographic Data Systems

Agilent ChemStation

Agilent EZChrom Elite

Agilent Cerity for Pharmaceutical QA/QC

Agilent 1200 Series detectors

Controllers

Agilent 1200 Series external valves

www.agilent.com/chem/1200detectors

16

For more information visit: www.agilent.com/chem/1200

All the time.

17

Agilent 6100 Series Single QuadrupoleLC/MS SystemsNominal mass detection

Agilent 6410 Triple Quadrupole LC/MSAccurate MS/MS quantification

Agilent 6210 Time-of-Flight LC/MSUltra-fast accurate mass

Agilent 6300 Series Ion TrapLC/MS SystemsSensitive MSn

Agilent 6510 Quadrupole Time-of-Flight LC/MSMS/MS structural information with accurate mass

Agilent 6000 Series LC/MS systems

Agilent 1200 Series HPLC-Chip/MS with nanospray source

Flow range: 0.1–1 µL/min

Ionization sources

Electrospray (ESI) Source Atmospheric PressureChemical Ionization (APCI) Source

Multimode Source (ESI/APCI)

Atmospheric PressurePhotoionization (APPI) Source

Nanospray Source Pulsed Dynamic Focusing MALDI(PDF-MALDI) Source

18

Scalable SolutionsFor multiple performance levels and future expandability

Speed and resolution

The performance of a liquid chromatographic system with regardsto speed and resolution is influencedby various aspects of the overall system. The automation capabilitiesand cycle times have a big impact on speed, whereas column technology,temperature, gradient and detectorperformance will affect both speed and resolution.

Sensitivity

• Electronic Flow Control (EFC)measures and actively controlsthe flow in real time for highestretention time stability

• Dedicated, thermostatted microautosamplers designed for reproducible injection of smallsample amounts, as low as 10 nL

• Theoretical sensitivity increaser = column radius

Sensitivity

Highest sensitivity detection, especiallyin combination with limited sampleamounts, is a challenge in applications,such as proteomics and drug metabolism studies. At constant injection volumes, decreasing the column inner diameter creates smaller elution volumes. This results in higher concentrations, as well as higher signals in concentration sensitive detectors, such as UVabsorbance or electrospray LC/MS.

Manual Isocratic LC SystemWorkhorse for demanding QA/QCapplications

• Entry-level system for world-class LC technology

• Easy and fast maintenance

• Flow rates up to 10 mL/min for a wide range of columndimensions and applications

• Upgrade options from isocraticup to automated quaternary LC system

Speed and resolution

Manual Isocratic LC SystemAutomated Quaternary LC SystemAutomated Binary LC SystemRapid Resolution LC System

HPLC-Chip/MS SystemNanoflow LC SystemCapillary LC SystemPreparative LC Systems

Pure LC

r12

r22

=

19

Nanoflow LC SystemUnsurpassed nanoflow performanceand stability

• Up to 3500 times more sensitivecompared to conventional LC

• Typical flow rates 0.1 – 1 µL/min,extendable up to 2.5 mL/min

• Compatibility with third-party MSplatforms

HPLC-Chip/MS SystemFor reliable high sensitivity nanospray LC/MS

• Up to 3500 times more sensitivecompared to conventional LC

• No peak dispersion for uncompromised chromatographicperformance

• Sample preparation and separation columns, connectioncapillaries, fittings and nanosprayemitter directly integrated on thepolymer chip

Rapid Resolution LC SystemHighest speed and resolution withuncompromised data quality

• Up to 60 % more resolutionand up to 20 times fastercompared to conventional LC

• Flow rates up to 5 mL/min provide universal applicability

• Full, uncompromised compatibilitywith existing methods

• Ideally suited for use with ZORBAX Rapid Resolution HT1.8 µm columns

• Throughput of 2000 samples per day

Automated Binary LC SystemFor research, high-throughput and fast applications

• High pressure gradient mixing for superior gradient performance even at lower flow rates

• Optimized delay volumes for fast chromatography

• Flow rates from 0.05 to 5 mL/minprovides ideal support for narrow and standard bore applications

Capillary LC SystemEnter the world of low flow applications

• Up to 500 times more sensitivecompared to conventional LC

• Typical flow rates 1 – 100 µL/min,extendable up to 2.5 mL/min

• Advanced diode array detectionfrom 190 – 950 nm

Automated Quaternary LC SystemFor routine method development and high throughput gradient applications

• Greatest flexibility for multi- solvent gradients by accessingup to 4 solvents

• Flow rates up to 10 mL/min support both standard boreand semi-preparative applications

• Wide selection of autosamplers for full flexibility in injection volumes and sample containers

For more information visit: www.agilent.com/chem/1200solutions

20

Preparative LC SolutionsFor isolation and purification with highest recovery and purity

Micro Collection/SpottingSystem

Allows the collection of microfractions in different well-plateformats and also provides users the advantage of combiningchromatography with the power of MALDI MS by direct spotting on MALDI targets.

Purification System

• Automated delay volume calibration

• Integrated safety features

• Software solutions for different user needs

• Smart fraction collection based on time, peak and mass, or both

• Active flow control for exceptionalflow stability

• Flexibility of collection in well-plates, Eppendorf tubes and MALDI targets

• Liquid control for highestreproducible collection of small volumes

• Fraction cooling preventsevaporation and thermaldecomposition

Purification System Preparative Scaleflow rates up to 100 mL/min

Purification System Analytical Scaleflow rates up to 10 mL/min

Micro Collection/Spotting Systemflow rates up to 100 µL/min

Flow rate

Preparative LC is the technique of choice for isolation and purification.For lowest peak dispersion, Agilenthas developed dedicated preparativesolutions for a range of samplequantities and flow rates, optimized for highest recovery and purity,throughput and productivity.

For more information visit: www.agilent.com/chem/1200purification

21

Maximize system performance andreliability for all your separation needsby combining the new Agilent 1200Series system with Agilent ZORBAXLC columns and LC supplies. Designedwith the same attention to detail,quality and superior performance you have come to expect from Agilent instruments and backed byover 30 years of chromatographyexperience, you can count on Agilent’scolumns and supplies to deliver thehigh quality results you need andexpect, time after time.

Unparalleled qualityand flexible choices withinthe ZORBAX LC column family

• Wide selection of chemistries –Eclipse XDB, StableBond, Extend,Bonus-RP, Rx and more

• Column sizes from nano topreparative scale

• Security of reproducible performancewith unparalleled column life over thousands of injections

• Individual column performancereports to document column-to-column and lot-to-lot reproducibility

• Superior particle strength for eventhe most demanding high pressureapplications

ZORBAX Eclipse LCcolumn family – an excellentfirst choice for your methoddevelopment needs

• Unsurpassed peak shapeperformance and superior,reproducible separations of basiccompounds with Eclipse Plus

• Flexible choices for a broad rangeof conditions and a wide varietyof sample types

• Broad selectivity choices forenhanced resolution with sixdifferent bonded phases (twoEclipse Plus, four Eclipse XDB)for the column that is bestfor your separation needs

• Quick and seamless methodtransfer from analytical to prepand to fast and ultra-fast LC withparticle sizes from 1.8 to 7 µm

Fast, high-throughputseparations maximize yourresources and improveproductivity

• Achieve higher speed withoutcompromising the quality of yourseparation with Rapid Resolutionand Rapid Resolution High-Throughput LC Columns

• Separations up to 20 times fasterwith 1.8 µm RRHT LC columns

• Lengths from 20 – 150 mm for highspeed and high resolution analyses

• 60% resolution improvement overconventional LC

• ZORBAX RRHT columns areavailable in 8 different bondedphases

For more information visit: www.agilent.com/chem/1200columns

Extensive LC Column PortfolioA superior level of chromatography performance to match your separation needs

ComplianceComplete qualification portfolio for highest level of operation

Agilent Qualification Portfolio is thecost-effective way to maximize systemoperability while minimizing regulatoryexposure. With a complete qualificationportfolio designed to maintain thehighest level of lab operation, Agilent’sservices account for all phases of a system’s life cycle and createcustomized compliance programsbased on your needs.

Partner Edition

Enterprise Edition managed by you.Licensed self-delivery of qualificationprotocols using the Agilent ComplianceEngine allows you to complementAgilent’s Enterprise Edition service by delivering the protocols when,where and how you want.

Software Edition

Fast, accurate and comprehensivequalification for Agilent software provides evidence that it is properlyinstalled and configured.

Network Edition

Patent-pending, metrology-basedIQ/OQ and troubleshooting service for your network helps to maximize network uptime while minimizing regulatory exposure. It is the perfect complement to data system implementation and infrastructure validation.

Classic Edition

Installation Qualification (IQ) Ensures that new Agilent hardwareand software is installed correctly from the moment it is unpacked to the point it is ready for operation.

Operational Qualification (OQ) A comprehensive test of the completesystem to ensure basic accuracy andprecision of instruments, as well asuncovering potential problems beforethey occur.

Instrument Re-Qualification (RQ)Ensures that the qualified status of a complete system is restored after a given component has been repaired.

Enterprise Edition

Organizations which utilize many different types and brands of analyticalinstruments can rely on Agilent astheir single source for instrument qualification.

Harmonized qualification protocolswith comparable results provide a consistent approach to completeinstrument qualification needs, now and in the future.

An independent 2004 LCGC magazine survey ranked AgilentNo. 1 in general compliance services, hardware and methodvalidation, and system suitability.

For more information visit: www.agilent.com/chem/compliance

“I believe Agilent provides the most complete range of compliance

validation services in the world”

Ludwig Huber, Compliance Fellow at Agilent Technologies

22

All the performance.All the time.

23

© Copyright 2006-2008 Agilent TechnologiesPrinted in Germany, November 1, 2008Publication Number 5989-5200EN

www.agilent.com/chem/1200

1200_SP_FINAL_240608_complete.qxp 10.11.2008 10:25 Seite 24