24
1 ADVANCED DESIGN™ OF COLUMNS Professor Russell Bridge Dr Andrew Wheeler Centre for Construction Technology and Research University of Western Sydney SEMINARS Sept. 2001 The Centre for Construction Technology and Research at the University of Western Sydney is progressively developing new design rules for OneSteel Reinforcing’s Guide to Reinforced Concrete Design. Top-tier design rules that meet the requirements for design by refined calculation defined in AS 3600-2001 are being released under the trademark of Advanced Design™. This presentation concerns rules being developed for advanced design of reinforced-concrete column cross-sections for strength. The design rules are proprietary and should only be used when OneSteel Reinforcing’s products are specified.

Advanced Design of RC Columns

Embed Size (px)

DESCRIPTION

Presentation of international seminars

Citation preview

Page 1: Advanced Design of RC Columns

1

ADVANCED DESIGN™ OF

COLUMNS

Professor Russell Bridge

Dr Andrew Wheeler

Centre for Construction Technology and ResearchUniversity of Western Sydney

SEMINARS Sept. 2001

The Centre for Construction Technology and Research at the University of

Western Sydney is progressively developing new design rules for OneSteel

Reinforcing’s Guide to Reinforced Concrete Design.

Top-tier design rules that meet the requirements for design by refined

calculation defined in AS 3600-2001 are being released under the trademark of

Advanced Design™. This presentation concerns rules being developed for

advanced design of reinforced-concrete column cross-sections for strength.

The design rules are proprietary and should only be used when OneSteel

Reinforcing’s products are specified.

Page 2: Advanced Design of RC Columns

2

ADVANCED DESIGN™ OF COLUMNS

500PLUS-CCS

SOFTWARE

COLUMN

CROSSSECTION

DESIGN

The advanced design rules have been incorporated in a new software package

called 500PLUS-CCS, “CCS” standing for “Column Cross-Section” which

will be demonstrated during the presentation.

The new design rules and software will provide the user with a better

determination of cross-section strength and allowing the safe and economical

use of higher strength materials.

The presentation looks at the design principles used in the determination of the

cross-sectional strength of a conventionally reinforced column.

Also presented are the principles used in advanced analysis which was used in

the development of the software package 500PLUS-CCS.

Page 3: Advanced Design of RC Columns

3

φ Nu

φ Mu

φ Muo

φ Nu0

Moment

Lo

ad

(M*, N*)(Unsafe)

(φ Mub, φ Nub)

Locus ofφ Mu, φ Nu

values

(M*, N*)(Safe)

M*

N*

LOAD-MOMENT STRENGTH INTERACTION - DESIGN

In the design of a reinforced concrete column the designer is primarily

concerned with obtaining a column for which the design action effects

(defined by combination of M*, N*) fall within the load-moment strength

interaction diagram. Typical load-moment strength interaction diagrams as

shown may be generated using either simplified methods or using advanced

analysis. The 500PLUS-CCS software enables the designer to use advanced

analysis methods to derive an accurate interaction diagram for design use.

The load moment strength interaction diagram is dependent on a number of

factors including the geometry of the cross-section, and the material properties

of both the concrete and reinforcement. One of the major advantages of the

advanced analysis is the ability to accurately predict the stress in a cross

section for a give strain distribution, thus providing an accurate means for

determining realistic column capacities.

Page 4: Advanced Design of RC Columns

4

Concrete• Four original Grades; new Grade; high strength

• f′c = 25, 32, 40, 50 MPa; 65 MPa; up to 90 MPa

• Maximum Strength = 0.85 f′c

Steel• 500N grade - 500PLUS (fsy = 500MPa)

CONCRETE AND STEEL MATERIALS

The Australian concrete structures code AS 3600 has previously limited the

maximum concrete strength of the concrete to 50 MPa, and an upper limit of

400 MPa on the nominal yield strength of the reinforcement. However, the

current standard AS 3600-2001 has increased the maximum concrete strength

to 65 MPa and allows the use of 500N grade reinforcement (yield stress

500MPa). In recognition of the industry need and based on current research,

the advanced analysis software also enables the use of high strength concrete

up to 90 MPa.

Page 5: Advanced Design of RC Columns

5

CONCRETE STRESS-STRAIN CURVE (CEB)

0

10

20

30

40

50

60

0 0.001 0.002 0.003 0.004 0.005 0.006 0.007 0.008

Strain εa

Str

essσ

c (

MP

a)

f' c = 50 MPa

f' c = 40 MPa

f' c = 32 MPa

f' c = 25 MPa

εo = 0.0022

σc = f (εa)f' c = 65 MPa

AS3600-2001

To define the concrete stress-strain relationship, the current commentary to the

standard recommends the use of the CEB curve when using advanced analysis

methods.

One key factor of the CEB curves is that the peak stress occurs at a strain of

0.002 and is independent of the concrete cylinder strength. The unloading

behaviour of the varying grades of concrete also differ significantly.

The standard also limits the maximum concrete stress of 85% of the cylinder

strength.

Page 6: Advanced Design of RC Columns

6

CONCRETE STRESS-STRAIN CURVE (COLLINS)

0

10

20

30

40

50

60

70

80

0 0.001 0.002 0.003 0.004 0.005 0.006 0.007 0.008

Strain εa

Str

es

c (

MP

a)

f' c = 85 MPa (Collins et al)

f' c = 50 MPa (CEB)

f' c = 25 MPa (CEB)

εo = 0.0022

σc = f (εa)

While the CEB curve is considered to be adequate for normal grades of

concrete, the authors recommend the use of the Collin’s concrete stress-strain

curve for high strength concretes.

Unlike the CEB curves, the strain at peak concrete stress is dependent on the

concrete cylinder strength.

As detailed previously, the maximum concrete stress is limited to 85 % of the

cylinder strength

Page 7: Advanced Design of RC Columns

7

εsy = 0.0020 for 400Y Grade

εsy = 0.0025 for 500Plus

STEEL STRESS-STRAIN CURVE

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 10 20 30 40 50 60

Relative Strain ε s /ε sy

Rela

tive S

tress

σs/f

sy

Design Assumption

Strain Hardening

Slope = E s = 200,000 MPa

1.0

The definition used for the material properties of the steel is the bi-linear

elastic plastic stress strain relationship with a linear elastic region to the yield

point. The modulus of elasticity for the steel is assumed to be constant at

200,000 MPa. Consequently, the strain at this yield point is assumed to be

0.002 for the 400Y Grade steel and 0.0025 for the 500PLUS® reinforcement.

The effects of the strain hardening of the steel are ignored for the advanced

analysis of columns.

Page 8: Advanced Design of RC Columns

8

Stress Resultants

N

M

Concrete Stress

DistributionAxis

Ne

utr

al

Steel Stress

Distribution

Strain Distributionεa

Curvatureρ = 1/R C

en

tre

Cross-section

Axis

AXIAL FORCE AND MOMENT AT A CROSS-SECTION

To determine the capacity of a column the assumption that plane sections

remain plane is utilised. An assumed strain distribution is applied to the cross-

section, defined by the curvature and axial strain at the centroid. From the

applied strain distribution and the pre-defined material properties, the stress

distribution in the concrete may be determined. The same method is use to

determine the stress distribution in the reinforcement. Once the stress

distribution is determined, integration is utilised to determine the axial load (N)

and the moment (M) for the given strain distribution.

Page 9: Advanced Design of RC Columns

9

LOAD-MOMENT-CURVATURE DIAGRAM

5000

4000

3000

2000

1000

0 100 200 300

Moment M (kNm)

Axia

l L

oad

N (k

N)

400 x 40050 cover8C24 bars

fsy = 410 MPa

f′c = 30 MPa

48

12 16 24 3240

60

80

120

160

8N24 Bars

The load-moment strength interaction diagram is determined by selecting a

curvature and varying the applied axial strain. For each value of axial strain, an

axial load (N) and moment (M) is determined and the curve of load-moment

values for a given curvature derived. This procedure is repeated for varying

values of curvature. Plotting values of load and moment for a constant value of

curvature results in the contour chart shown in the slide above. A 3D model of

this behaviour shown in next slide, where load (N) is on the y axis, moment (M)

on the x axis and curvature (ρ) on the z axis. Viewing the x-y axis, then the

envelope of (N, M) values defines the load-moment strength interaction

diagram.

Page 10: Advanced Design of RC Columns

10

LOAD-MOMENT-CURVATURE DIAGRAM

A 3D model of the load-moment-curvature behaviour of a typical column

cross-section is shown above. This was constructed using the contour diagram

shown in the previous slide. The lines marked on the model are lines of

constant curvature, the vertical axis is the load axis and the horizontal axis is

the moment axis.

Page 11: Advanced Design of RC Columns

11

d

do

εcu

kud

Muo

εcu

kuodoεsy

Mub , Nub

Mul , Nul

do

εcu

Nuo

Moment

Ax

ial L

oa

dKEY POINTS ON LOAD-MOMENT INTERACTION CURVE

When using simplified methods or advanced analysis, a number of key points

are defined on the load moment strength interaction diagram. These points are

used in the determination of the appropriate capacity reduction factors, and

include the axial capacity (Nuo), the bending capacity (Muo) and the balance

point (Mub, Nub).

The axial capacity (Nuo) is the capacity of the section when a constant strain is

applied across the cross-section. For 400Y Grade reinforcement this point

would always corresponds with the strain at which the peak concrete stress is

reached. The pure moment capacity (Muo) is the maximum bending capacity of

the column with zero axial load. The depth to the neutral axis (koud) at this

point is needed, as it is used as a measure of ductility of the cross-section. The

capacity reduction factor (φ) at pure moment is dependent on the value of kuo.

As the axial load applied to a column is increased from zero, the moment

capacity will increase as applied axial strains relieve some of the tensile strains

resulting from the bending. As these compressive strains increase, they will

reach a point at which they begin to decrease the bending capacity of the

column. This transition point is considered to be the balance point (Mub, Nub).

For rectangular sections, and particularly those that are singly reinforced, this

point occurs when the steel on the extreme tensile face begins to yield. When

the cross-section is non-rectangular or has multiple layers of reinforcement,

the peak moment may not always occur when the reinforcement on the

extreme tensile face begins to yield. Using advanced analysis methods, the

transition point between applied axial load contributing or degrading the axial

capacity is determined accurately.

Page 12: Advanced Design of RC Columns

12

0.60.8or0.8uo

ud ≥==M

M00 φφ

Pure Bending where Nu = 0

Combined Bending and Compression where Nu < Nub

−−+= ))((

ub

u0

N

N10.60.6 φφ

Combined Bending and Compression where Nu > Nub

0.6=φ

CAPACITY REDUCTION FACTOR φ

Capacity reduction factors (φ), as defined by AS 3600, are dependent on theapplied axial load (N). When the applied load (N) is greater that the axial load

at the balance point (Nub), the column is considered to be predominantly under

axial loading and a reduction factor (φ) of 0.6 is applied. When the axial load

(N) is below the balance point (Nub), bending is considered to be critical so

providing kuo is less than 0.4 the reduction factor (φ) is varied linearly from 0.6at the balance point to 0.8 for pure moment.

Page 13: Advanced Design of RC Columns

13

0

100

200

300

400

500

600

700

800

900

0 1 2 3 4 5 6 7 8 9 10

Percentage Steel %

Mo

me

nt

Str

en

gth

- P

ure

Be

nd

ing

(k

Nm

)

Ca

pa

cit

y F

ac

tor φ

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

M ud

ku = 0.4 M uo

φ M uo

400 x 400

50 coverf sy = 500 MPa

f' c = 32 MPaφ

STRENGTH IN PURE BENDING

For cross-sections where kuo is greater than 0.4, a reduction factor (φ) isreduced further to overcome the potential ductility problems. This reduction is

based on the assumed moment capacity Mud which is a theoretical moment

capacity based on a value of kuo = 0.4.

Page 14: Advanced Design of RC Columns

14

0

2000

4000

6000

8000

0 100 200 300 400 500

Moment (kNm)

Lo

ad

(

kN

)

Locus

φM u, φ N u

values

Locus

Mu, N u

valuesφ N uo

N uo

400 x 400

50 coverf sy = 500 MPa

f' c = 32 MPa

Mu

o

Rectangular Stress

Analytical Method

NOMINAL AND DESIGN STRENGTH

The effect of the reduction factor is very significant on the overall capacities of

the cross-section. Thus optimisation using advanced analysis is critical to

obtain the best performance permitted for the column. The advanced analysis

enables an accurate prediction of the balance point, along with determining the

maximum permitted value of Mud.

Page 15: Advanced Design of RC Columns

15

SLENDER CONCRETE COLUMN

When looking at slender columns, AS 3600 allows the use of moment

magnification factors to take into account the effects of slenderness. The

software included is only for determining the cross-sectional strength, and thus

does not consider slender columns.

Page 16: Advanced Design of RC Columns

16

MINIMUM REINFORCEMENT IN COLUMN

Min. 1% steel400Y Grade

0.8% steel500 PLUS

εsh shrinkage strain = 850 µstrain

φccb creep factor = 7.5

Loading = 0.4φNuo = 40% squash load

Stresses in steel with time

The minimum steel requirements for columns governed by strength as

specified by AS 3600 is 1 percent. The commentary to the concrete standard

suggests that this limit "guards against yielding of the reinforcement due to

shrinkage and to creep under sustained service loading".

Page 17: Advanced Design of RC Columns

17

CREEP AND SHRINKAGE STRESSES IN STEEL

0

100

200

300

400

500

Time after Loading

Ste

el S

tre

ss

(M

Pa

)

1.0% 400Y Rebar

0.8% 500PLUS Rebar

1 3 10 30 30100 1 3 10

Days Years

Studies have shown that for a column with 1 percent 400Y Grade

reinforcement, when compared with an similar column with 0.8 percent

500PLUS® reinforcement and subjected to identical shrinkage strains, the

same creep coefficient and supporting the same sustained service load (see

previous slide) the stresses in the reinforcement of each column are very

similar. Consequently, the advanced analysis will allow the design of columns

with less that 1 percent reinforcement for 500PLUS® reinforcement.

Page 18: Advanced Design of RC Columns

18

COVER SPALLING IN HIGH STRENGTH CONCRETE

Spalled concrete cover

Confined concrete

Nuo = kf´c Ac + fsy As

For f´c ≤ 65 MPa, k = 0.85

The use of concrete grades above those specified in AS 3600 introduce a

number of additional problems. A primary consideration is the effect of

spalling of the concrete cover on the axial strength of columns.

Page 19: Advanced Design of RC Columns

19

EFFECT OF COVER SPALLING ON STRENGTH

0.50

0.55

0.60

0.65

0.70

0.75

0.80

0.85

0.90

0.95

1.00

0 20 40 60 80 100 120

Concrete Grade (MPa)

Str

en

gth

Facto

r k

To overcome the effect of cover spaling, the maximum concrete stress allowed

for design is decreased. Numerous experimental studies have demonstrated

that for concretes with cylinder strength up to about 65 Mpa, the peak stress

reduction factor (k) of 0.85 as specified by the standard may be adequate.

However, as the concrete cylinder strength moves beyond this point, the peak

stress reduction factor should decrease to a lower value. A limit of 0.72 has

been suggested in some studies.

Page 20: Advanced Design of RC Columns

20

COMPARISON OF HIGH STRENGTH CONCRETE

0

1000

2000

3000

4000

5000

6000

7000

0 100 200 300 400

Moment Capacity φM u (kN/m)

Ax

ial

Lo

ad

Ca

pa

cit

Nu

(k

N)

50 MPa

85 MPa

High strength concretes, for a given cross-section, result in an increase in axial

load capacity, including the effects of cover spalling, but have an insignificant

effect on the pure moment capacity.

When using the high strength concrete the designer should also ensure that the

spacing and layout of the confinement reinforcement meet the desired

requirements.

Page 21: Advanced Design of RC Columns

21

ADVANTAGES OF ADVANCED DESIGN™ FOR COLUMNS

• Full non-linear material properties

• Numerical integration of stresses for accuracy

• No assumptions for concrete strain at ultimate strength

• High strength concrete HSC included (up to 90 MPa)

• Proper definition of load (Nub) balanced point

• Calculation of maximum value of reduced moment Mud

• Use of maximum values of capacity reduction factor φ

• Reduction in value of minimum reinforcement

• Inclusion of effect of spalling of concrete cover for HSC

Page 22: Advanced Design of RC Columns

22

USE 20% LESS STEEL WITH 500 PLUS REBAR

0

10

20

30

40

0 1 2 3 4 5 6

M u /A gD (MPa)

Nu

/Ag

(MP

a)

0.0% steel

1.0% steel 400Y

0.8% steel 500PLUS

2.0% steel 400Y

1.6% steel 500PLUS

450

700

f'c = 32 MPa

Comparisons between 400Y grade reinforcement and 500PLUS®

reinforcement are demonstrated here.

In the cases shown, a simple replacement of 20 percent less reinforcement

results in a similar column behaviour.

Page 23: Advanced Design of RC Columns

23

0

10

20

30

40

0 1 2 3 4 5 6M u/A gD (MPa)

Nu/A

g

(MP

a)

0% steel 1% steel 400Y

1% steel 500PLUS 2% steel 400Y

2% steel 500PLUS

450

700f' c = 32 MPa

500PLUS REBAR AS DIRECT REPLACEMENT

Further comparisons between 400Y grade reinforcement and 500PLUS®

reinforcement are demonstrated here.

In the cases shown, a simple substitution of the higher grade reinforcement

results in an increase in both axial load and moment capacity.

Page 24: Advanced Design of RC Columns

24

• Practice based on supporting research

• Advanced analysis of concrete cross-sections

• Use of high strength concrete

• Advantages of 500PLUS® Rebar

• Accurate software for design

• Ongoing development and research

CONCLUSIONS