68
VISTA 4 V40XMPI!2 PARTITIONED SECURITY SYSTEM WITH SCHEDULING INSTALLATIONINSTRUCTIONS E!m!EEl 4140XMPT2-INST S/93 (pat of N5944-2)

ADEMCO manual 4140

Embed Size (px)

DESCRIPTION

ADEMCO manual 4140

Citation preview

Page 1: ADEMCO manual 4140

VISTA4 V40XMPI!2

PARTITIONED SECURITY SYSTEMWITH SCHEDULING

INSTALLATIONINSTRUCTIONS

E!m!EEl4140XMPT2-INST S/93 (pat of N5944-2)

Page 2: ADEMCO manual 4140

CONGRATU’TIONS!On Your Purchase Of The Ademco 4140XMPT2 w

The purpose of these Installation Instructions is to give you a completeoverview of the system, and provide instructions for installing a basicsystem.

CONTACTING TECHNICAL SUPPORT

PLEASE,Before you call Technical Support, be sure you:

c READ THE INSTRUCTIONS!c Check all wiring connections.c Determine that the power supply and/or backup battery are

supplying proper voltages.c Verify your programming information where applicable.● Note the proper model number of this product, and the

version level (if known) along with any documentation thatcame with the product.

QNote your ADEMCO customer number and/or companyname.

Having this information handy will make it easier for us to serveyou quickly and effectively.

You may contact Technical Support via Toll Free Fax. Please include yourreturn fax number. You will receive a reply within 24 hours. You may alsocontact Technical Support via modem to ATLIS-BBS, Tech Support’sElectronic Bulletin Board System. Replies are posted within 24 hours.

East Coast Technical Support: 1-800-645-7492 (8 a.na.-6 p.m. E.S. T.)West Coast Technical Support: 1-800-458-9469 (8 a.m.-5 p.m. P.S. T.)

Technical Support Fax Number: 1-800-447-5086ATLIS-BBS Electronic Bulletin Board System: 1-516-496-3980

(1200 -9600 Baud, 8 Data Bits, 1 Start/Stop Bit, No Parity)

-2-

Page 3: ADEMCO manual 4140

SUMMARY OF SYSTEM FEATURES ................,,,.......................................................................5General Information .................. .............................................................................. .........5System Features ........................................................................................... ..................6Programming Features .......... .. .. .......................... ............ ..................... ......... ........ ...........7Communication Features ............................................... ...................................................7

INTRODUCTIONTO THE PARTITIONED SYSTEM........................................................................8Introduction ....................................................................... ..................... .......................8Bask Patitibning Features ........ ........................................................................ ...............8Examples ~Patiitioning ... .. .............................................................................................9Global Partitioning Featuresand Resources ............... ......................... ............... ..................9Partition Specific Features ......... ......... ........................................................... .......... .........9

SCHEDULINGOVERVIEW ............... .................................. .....................................................10Ma@rFeatur~~Whduling ... .. .................................. .......................................... ....... ....lOAccessDoorControl ................. .................................. .....................................................10Time-Driven Event Programming .......................................................................!..... ............10End User Scheduling (#83 Menu Mode)....... ....................................................... ..................10

ZONE TYPES & APPLICABLE SENSORS ...................................................................................llBASIC9HARD-WIRED ZONES ......... ......... .......... ............. .. ........................... ..........................13

Zone l ...........................................................................................................................l3Zone 9........... .................................................................................................... ............l3Zones 2.8 ........................... .. ...................................... ............................. .....................l4

2-WIRE POLLING LOOP EXPANSION (Zones 10through 87).........................................................l5General ltiormation ...... ............ ............. ........... .......... .....................................................l5Intercom lntederence ............. ...... ...........m.................. ........................................ .............l5Advisories .. .. ...................................... ...........................................................................l5lm~tiantl Fauh Annunciation ....................................... ............................. ........................l6timpatible Polli~Loop Devi@s ........................................... .............................................l6

WIRELESS EXPANSION (Zones 1-63) .......................................................................................l7General information .................. ........................................ ...............................................l74280Seties Raeiver .. .............. ................... ............... .. ....................... ............................l84281 Seties R~eiver ................ ......... ............... .......... .... .............................. ...................185881 Seties Rweiver .............. .. ............... ........... ........ ....................... ........... ...... .. ..... ......l 8Transmitters .......................... .................................... ............................ .........................l9Wireless Zone Types ........................................................................................................2OAdvisories .................. ......... ............................................ ................................. ....... ......2OFault Annunciation .................................................................................................... .......2OImportant Battery Notice ...................................................................................................2lCompatible5700 Series Wireless Devices............. ......... ......... ................. .......... ..................2lCompatible5800 Sefies Mreless Devices............................................................................22

VOLTAGE TRIGGERS (tinnmor J7) ............ ................... ... ...... ............................ ...................23General information .... ...... ........ .. ............... .. ............... .. ................................ ...... .............23Ground &ad Mdule . ......................... ......................... .... ................. .. ......... .. ...................23Remote Keyswitch ............................................................................. ..............................24Remote Console Sounder Operation ....................................................................................25

0UTPUTCONTROL(4204RelayModule/X-10 Devices) ........... ............................... ......................26General ltiormation ........................................ ............ .......................... ........ ...................264204 Relay Module . ....................... .......... ................... ................... ............... .... ............. ..264300 Transformer & X-10 Devices .......................................................................................26Examples Of Uses For Relay s............................................................................................27

REMoTEwNsoLEs ....... ............. ............ ...................................... ................... ...................3oGeneral ...... ................ ........... ........................... ....... .. ................... .......... .... ...................3o4137m ............ .. ........... ........ .................................. .............. ........................................3o5137AD ............ ..................... ........ .. ............... ......... ............................. ................... ......3o6139 .. ............ ............. ........ ........................... ....... ......................................................3oPrqramming The tinsoles .............. .......................... .................................... ...................3lMounting ~etinwles ........... .. .............................................................. ...... .......... .........3lWtingtinwles ............. .. ....... ................ ..................................................... .. ....... ..........3lPoweting Additional Conales ................................... ...................................... ...................3l

EXTERNALSOUNDERS ........................................ .................. ......... ................... .......... .........32Relay OutWt . .. .............. ............................................................................ .....................32UL Household Installations ................................................................................................32Non.ULlnstallations ............. ............. ..................... ...................................... ...................32timpatibie Sounders ............ ...... ......... ......................................................... ........... ........32

PHONEwNNEcToNs ........................... ........ ..................... ........................ .. .......................32-3-

Page 4: ADEMCO manual 4140

Mounting ~eCabinet Lo& .......... ................. ......... ...........................................................33

PrtmarylJower ........... .................................. ...................................................................34Ba&.Up Power .......... ........ .......................... .......... ...................................... .. .................34Earth Ground Connections ................................................. ............... ............. ...................34Power-UpProcedu re... .......... ....................... ...................... .............. ....... ................. ........34

SEITING THE REAL-TIME CLOCK ............................................................................................36●

SECURITYACCESS CQDES .................. ................................................. ................. ...............37General Information ............................................................. ............ ................................37User Codes & Levels Of Authority .......................................................................................37Multiple Partition Access Examples .................... ................................ ................................39To ADD a Master, Manager or Operator code .........................................................................4OTo CHANGE a Master, Manageror Operator code ......... ............................................ .......... ...41To Deletea Master, ManagerorOperator de ... .......... .........................................................4lTo EXIT The User Code Entry Mode.....................................................................................4l

KEYPADFUNCTIONS ..... .. ............................... ... ................................... ..................... ...........42General information .... .......................................... ........................... .... ............................42Arming Functions ....... .................................. ........ ..................... ......................................42A=esstintrol .. ........ .. ........ ............... ......... .................................... ............ ...................~Delay closing window ............................................ .................................................. .........~Pa~ition "Goto"timmands ..................... ................................................ ..........................UView Capabilities Of A User ................... ............ ................................ .............................. ..43Viewing Downloaded Messages ..........................................................................................~Using The Buik.ln User's Manual ............................................. ........... ................................~Displaying Descriptors ............................. ...................................... .. ........................ ........44Panic Keys ..... ...................................... ...... .... .............................................. .................44Trouble Conditions ...........................................................................................................~"Ch=k Messages ..... ............................... ... ................................... ................................UOtherTrouble Conditions ............................ .................................... .. ................. ...............MPower Failure .......... ................................................................................. ................ .......~

EvENTLmGING ............ ........ ....... ...... ....................D................. .......... ................... .............45~ \Event Logging Printer Connections ..................................................... ................... .............45Event kgging Procedures ................................................................ ................................46Prqramming ............. ......... ........ ................. ................. ................... .......... .....................46Event Logging Display & Print Modes ............... ................................... ............ ....................46Clear Event Log ..... ........ ...... ........................ ............................. ...... ......... .. .....................47Screen Definkions ...... ........................... ....... .......... ......................... ........... ................. ....47

DIRECT WIRE Downloading ................................................................................................48

Spli~ual Re~tiing .... ............ ......................................................... ................................49AdemmbwSpd .............. .. ....... ..................................................................................49SescotiRadionics ........................................ ............................... ....................................49&2 Re~tiing ............ ............. ................ ..... ..................... ..............................................494+2 Express ....... ........................... ........................................................................ .........50Ademm High Speed RepfliW .. ................. ................. .......... ................. ................. ...........5OContact ID Reporting ........................................................................................................5l

U:ing Test Mode .. ...... ........ .......................................................................... ......... ..........52Armed System Test .... .. ................... ............................................ ....................................52Turning The System OverTo~e User ............. ........................ .................................. .........53

DIP SWITCH TABLES .............................................................................................................56suMMmYoFsYsTEMmMANDs ......................................... .................................. ...... .. .....59

-4-

Page 5: ADEMCO manual 4140

SUMMARY OF SYSTEM FEATURESGeneral Information

NOTE: At least one5137AD or 6139

addressable alphadisplay console must

be used with thissystem.

The following table lists the major features of the 4140XMPT2 system.

~ystem The 4140XMPT2 Control is a microprocessor based,programmable, partitioned system, and features EEROMmemoty technology (power bss does not result in thebss of information).

?ones Supported ● Suppotts up to 9 traditional wired zones of protection.Q Expandable to 87 zones (consisting of combinations of

wired and/or wireless zones) using 2-wire polling bopdevices, and/or 5700 or 5800 series wirelesstransnltfers.

● Zones oan be distributed among up to 8 bgioal partitionsof operation.

%e Zones ● Supports up to sixteen 2-wire smoke detectors (zone 1).● Other zones can be fire zones using 4-wire smoke and

heat detectors and/or polling loop detectors.

3utput Control ● Supports up to 16 devices (4204 relay modules or X-1Odevices).

● These devices can be put under schedule mntrol.

Remote Consoles ● Supports up to sixteen addressable remote consoles(6139, 5137AD, 4137AD).

Keyswitch Supports the Ademco 4146 keyswitch.

Programming ● Programming can be performed at the office prior toinstallation, or on the job site directly from the console.

● Can be downloaded from a remote location or at the jobsite (using a PC/laptop with 41OOSMSerial Module) byusing the Ademco 4130PC Downloading Software.

● The Control is pre-programmed with a set of standardvalues that is designed to meet the needs of manyinstallations. These values, however, can be changed tosuit the needs of any particular installation.

● The Control can also be pre-programmed by the installerwith one of four standard communication defaultprogramming values, thus further saving time and effort.

User Codes Supports up to 128 user codes, maximum of 99 perpaftition

Panic Keys Provides 3 panic key functions.

Communication Ademco low speed, SESCOA/RADIONICS, AdemcoExpress, Ademco High Speed, Ademco Contact ID

Before Installing this partitioned system, become completely familiarwith the partitioning concepts, including zone distribution (each zone can beassigned to only one partition), user code usage and authority levels, and theuser-friendly menu mode of programming. In addition, become familiar with thescheduling and output relay features.

-5-

Page 6: ADEMCO manual 4140

The following table lists the sDecial system features of the 4140XMPT2 svstem.

Global Arming

Polling Loop

Glass Break Detectol

Quick Bypass(Forced 6ypaSS)

Memory-Of-Alarm

Circuit Breakers

Built-in Users Manua

Descriptors

Cabinet

Scheduling

Wireless

Event Logging

Access Control

● Allows users to easily arm multiple partitions via consoleDromDts.

● Built-in polling loop interface, with polling loop terminalslocated on the panel’s terminal block, allows expansionup to 87 zones.

● Supports up to 50 latching type 2-wire glass breakdetectors on zone 8.

● Quick (forced) bypass feature bypasses ail faultedzones with single key entry sequence.

● Memory-of-alarm feature, which, upon disarming thesystem, automatically displays all zones that were in analarm condition while the system was armed.

“ Self resetting cirwit breaker protection eliminates theneed to replace blown cartridge fuses.

● Built-in Users Manual (5137 AD/6139 onlv). Bvdepressing and holding any”of the function keys-on th~console for 5 seconds, a brief explanation of thatfunction scrolls across the alpha-numeric display.

● All programmed descriptors can be displayed (one at atime) by pressing and holding the READY key for 5seconds, then releasing the key. This serves as a checkfor installers to be sure all descriptors are enteredproperly.

● Large cabinet with removable door for easierinstallations.

● Scheduling feature allows installer and/or user toautomate system operation and/or turn on lights, etc.

● Auto-arm/disarm of system.● Tempora~ schedules can be programmed by user.● System operation can be restricted to cerlain times.

● Wireless suppoti of 5700 or 5800 series transmittersusing 4280, 4281 or 5881 type receivers.

● Event Logging feature keeps record of all events, whichcan be printed automatically or on demand.

“ Provides user activated access control command whichpulses a relay output for controlled opening of accessdoors.

-4

-6-

Page 7: ADEMCO manual 4140

. .. . . . . .. . .. . . . . .. . . . . . .. . . . . .Programming Poaturos

CommunicationFeatures

.-

User Codes . Up to 128 user 8ecurity @e8 (maxt 99 per paftitbn) canbe programmed, each with varbu8 leve18 of authorfty.

ln8taller Code ● Installer code override feature. Installer code will dbarmsystem only if it was used to ann the system.

Alpha Descriptors ● Aii zones and partitions can be assigned alphadescriptions.

● The ietter “s” or”’$” can be added to descriMors,

Custom WordsI

● Up to 20 custom words can be added to the built-invooabularv,

Comm. FieidsI

● Easy programming for communication fieids, Simpiyenter the reuml code for each zone.

Comm. Defauits ● Communication defauit programming can be ioadedanytime, and does not affect non-communicationprogramfieids.

Downloading I● Direct wire downloading can be done without a modem,by using a PC or Laptop computer and 41OOSMSeriaiModuie.

#93 Menu Mode ● Easy programming of zones using the user friendiy #93Menu Mode.

Scheduling Menus ● Easy scheduling programming using the #80 MenuMode.

The foiiowing tabie iists the communication features of the 4140XMPT2 system.

Zone Reports ● Aii 87 zones can report to a centrai station using anyreporting format.

Exception Reporting ● Open/close reporting by exception means reports occuronly if outside predetermined time windows.

Caiiback ● Caliback defeat option for downloading.

Reai-Time Cbck ● Reai-Time ciock for time reiated functions. NOTE:5137AD or 6139 aipha consoie must be used to set thereai-time ciock, or can be set using Downloader software.

AC Loss Reporting ● Random AC Loss and AC Restore reporting optionsends report randomiy from 10-40 minutes after AC ioss,to heip prevent centrai stations from receiving anoverioad of reports due to area biackouts.

Test Reporting ● Inteiiigent test reporting option means test reports wilinot be sent if any other report was sent within theprogrammed test repod intervai.

Spiit/Duai Reporting “ SpliUDuai reporting communicator options avaiiabie.

Cancel Report ● Option to aliow a cancei report to be sent, even after BeilTime-out has ended.

Voitage Triggers ● Used to interface with LORRA or other devices.● PC Downloader can command output voltage triggers to

puise on for 2 seconds.

Phone Numbers ● Primary and secondary phone number capability.“ Can program different formats for each phone number.

UL NOTE: Downloading is not permissible for UL installations.

-7-

Page 8: ADEMCO manual 4140

This section IS Intended to aivo vou an overview of ~artitlonlna conce~te. For speelfic questions onprogramming or using spe;iflc ‘aspects of the pa~el, pleae~ refsr ‘to the SYSTEM ‘OPERATIONsection of this msnual snd the PROGRAMMING GUIDE.

Introduction The partitioned system represents the latest in security protection technology.Combining wired, wireless and polling loop zones into one powerful control, thiscontrol communicator is capable of supporting a true “partitioned” environment. Apartitioned environment is one whereby multiple unrelated users wish to beprotected by a security system, yet each user requires the operational freedom tohave the system behave as if it was theirs and theirs alone. This global definitionimtMies a lot of thinas in terms of the required features of the equipment you willinstall. Some basic f;atures are listed below:

. .

—.- . . . . . -,. -.-,., –-. ,., -.. .– ... . . .... . ..—-------- -. .L– . . .A”, .m-l-- -.. _.-—6asic ParmtionmgFeatures

Simple ● Easy to use and program as the simplest alarm system,

Secure ● Integrity of security is not compromised for any users ofthe svstem.

Reliable “ Inherent reliability of the partitioned system is equal to astand alone alafi system-if purchased separately;

Consoies c Flexible number of consoles per partition (up to a total of16 in a system, an~ay you want to assign’them).

● Appropriate sounds and messages to assignedconsoles only (each system appears to be independentto users).

“ Ability to inhibit other consoles from using your partition(total security in a strip mall environment).

User Codes ● 128 User Codes assigned virtually anyway you wantthem (99 max. in any partition, otherwise no restrictions).Enough to handle the largest commercial jobs.

● Multiple levels of authority per partition (allows keypeople in a partition to have complete control and limitsystem tampering by others).

Zones “ 87 zones employing wired, wireless or multiplextechnology (install any mix for any type of constructionchallenges).

Partitions ● Any zone can be assigned to any particular partition(easy to install, allows logical assgnment by the dealer).

● “GOTO function provides access to other partitions(ideal for executive access to factory for example).

● Intelligent partition/zone menu programming help(simplifies the programming and reduces errors)

● Programmable 4-character partition name displayed onalpha consoles when needed (no need to memorizenumbers - name and number are shown for You).

-8-

Page 9: ADEMCO manual 4140

Examnles Of In survevirm dealers throughout the countrv, we have learned of two globalPartitlonlng

Global PartltlonlngFeatures and

Resources

Partition SpeclflcFeatures

applicatibn;for partitioned %ontrol panels. ‘One is a typical two family fiouse(residential), the other a Factory/Office environment. These broad classificationscan better be understood by way of examples.Two Family House: You’ve just arrived at a job site to quote a security system.The owner wants an alarm system which he can use for his family (living upstairs)and he also wants to provide protection for the separate living quarters of hismother (living downstairs with separate entrance). The owner obviously wants tokeep costs down yet provide protection and flexibility for his mother livingdownstairs. You could choose to install a traditional alarm panel to keep costsdown, but the system woukf be very limiting for either the mother or the upstairsfamily. To meet the flexibility requirements as desired, you could install twotraditional alarm panels, but the cost might cause you to lose the business. The4140XMPT2 solves all these problems.Factory/OffIce: You arrive at a small manufacturing concern boking to provideprotection throughout their offices as well as their factory. The very nature of thebusiness is such that factory workers come to work at 7:30AM and leave at 4PM,while the offices are open 8:30AM to 6:OOPM.Some executives even want tostay late at night or come back to work after 6:OOPM. Installing two panels (one forthe factory, one for the offices) would certainly work at a cost premium, but thinkof all the complexity when owners tried to gain access to the factory afterhours...two access codes to remember, accidental false alarms. Even the realfrustration of not being able to properly program the two systems to allow easyaccess from the factory to office or vice versa! Install a partitioned system, yourprogramming problems are over, and the owners of the business will appreciateits flexibility and ease of use!

In any system, cefiain physical system components and features are shared by allpartitions or assigned to a specific partition. The following elements are shared orassignable to a specific artition:

Shared By All Partitions Assignable To One PartitionDialer dAlarm Relay/Sounder d # (using relay outputs)Power Supply dWireless Keypad /Keyswitch Station /

In addition to the physical devices which are shared, the system shares somesoftware features on a global basis as well. These include:

Panic Code Reports .........................................Comnm code for any partitionLow Battery Reporting ......................................Repods as Partition 1AC Power Reporting Options ............................Repofls as Partition 1Test Reporting Interval .....................................Global for the PanelDownload Phone Number ................................Global forthe PanelCommunication Format .....................................Global forthe PanelRotary/Touch Tone ..........................................Global for the PanelDownload Callback defeat .................................Global for the PanelInstaller Code ...................................................Gbklfor all Partitions

Many devices and functions need to be reserved on a partition basis to provideproper operation and flexibility for installations. The items assignable on a perpartition basis include:

● Consoles ● Enable/Disable Chime ModeQEntry and Exit Delays ● “Go To” Partition functions Console Sound during Exit Delay ● Swinger Suppression● Primary Subscriber Number ● BurglaryAlarm Comm. Delay● Secondary Subscriber Number cOpen/close for Installer Codec Enable/Disable of Panic Keys ● Confirmation of Arming Ding● Enable/Disable of Duress ● Alarm Sounder Duration● Multiple Alarm Reporting ● User CodessQuick Arm enable/disable● Inhibfl Bypass of one Zone

-9-

Page 10: ADEMCO manual 4140

Major Features OfScheduling

Access Door Control

Time-DrivenEvent Programming

End User Scheduling(#83 Menu Mode)

Scheduling is an exciting new feature of the 4140XMPT2 and provides thefollowing ftinctions. -

Arm/Disarm control I

Scheduling can be used to automate some of the system operation:Auto arming and disarming at predetermined times.Auto-arm warningUser option to delay auto armProvision for temporary schedule of up to one weekProvision for a holiday scheduleLimitation of arming and disarming to specific times—Control of when disarming will occur

Open/close by exceptionScheduling provides a means of reporting openings/closings by exception:

sends report only if action does not occur.Inhibfl opening/closing reports if within a Time Window—Send early to operVclose reports if done earlier than window—

c Send late to open/close reports if window is missed.

Relay Control (Time Driven Events)Scheduling can also automatically perform relay driven actions at predeterminedtimes:

Can turn lights or other devices ordoff at specific times—One shot action of light or other deviceX-1Ocontrol for the automation of lights and appliances—

Daylight Savings TimeAutomatic time adjustment for daylight savings time—

Scheduled events are programmed using a user friendly menu mode ofprogramming (#80 mode), explained in detail in the separate PROGRAMMINGGUIDE. This menu programming takes you step by step through the options.The following overview will give you an understanding of the schedulingconcepts. Refer to the PROGRAMMING GUIDE for detailed programminginstructions.

The system also provides a means of access control. Entry of USER CODE+ Owill cause a momentary trigger of a pre-set output device. Each partition can haveits own output device. The trigger will occur on the device tied to the partition forthe console on which the keys were pressed. The access control relay isprogrammed in partition-specific field 1’76.

This very powerful feature allows arming, disarming, relay modules or X-1Odevices to be activated automatically, based on the time windows describedpreviously. Time driven events can also be used to assign additional open/closewindow schedules, so that more than one schedule per day can be programmed.The system supports up to 20 time driven events. Refer to the PROGRAMMINGGUIDE-Scheduling Programming for more detailed information.

The system provides up to 20 “timers” available to the end user for the purposeof activating output devices at preset times and on preset days. These timers areanalogous to the individual appliance timers that might be purchased at adepartment store. The typical uses for this feature could be control of lights orappliances, typically via X-1Omodules. These modules are programmed into thesystem by the installer during #93 Menu Mode-Device Programming. The enduser needs only to know the output device number (relay number) and its alphadescriptor, both programmed by the installer via Relay Programming and AlphaProgramming respectively. To enter this mode, the user enters CODE+ # + 83.

The installer may set certain relays to be “Restricted”, since a system may havesome devices (Relays or X-1O)which are not intended to be under the control ofend users, such as relays activating fire doors or relays activating certainmachinery. This option, set during #93 Menu Mode-Relay Programming, willrestrict operation by the end user. w

-1o-

Page 11: ADEMCO manual 4140

ZONE TYPES & APPLICABLE SENSORS

Type 00Zone Not Used

Type 01Entry/Exit #1 Burglary.

Type 02Entry/Exit #2 Burglary.

Type 03Perimeter Burglary.

Type 04Interior, Follower.

Type 05Trouble by Day/Alarm

by Night.

The 4140XMPT2 supports up to 87 zones of hard-wire, polling loop and/orwireless protection, distributed among up to 8 partitions. The following table liststhe zone numbers and the types of sensors that can be used with each in thissystem:

one Sensors1 2-wire smoke detectors (if used)7 keyswitch (if used)8 latching type glass break detectors (if used)1-9 traditional hard-wired zones1-63 5700 eeries wirelees devices1-87 5800 series wireless devices10-87 polling loop devices95 “/1 panic96 #13panic99 ●/# panicEach zone must be assigned to a zone type, which defines the way in which thesystem responds to faults in that zone. In addition, there are three keypadactivated zones (PANIC keys, see note below) for each partition, a polling loopsupervision zone, and four RF supervisory zones, two for each RF Receiverinstalled, Zone types are defined below.

Program a zone with this zone type if the zone is not used,

This zone type provides entry delay whenever the zone is faulted if the control isarmed in the Away or Stay modes. When the panel is armed in the Instant orMaximum modes, no entry delay is provided. Exit delay begins whenever thecontrol is armed, regardless of the arming mode selected. These delays areprogrammable. This zone type is usually assigned to sensors or contacts ondoors through which primary entry and exit will take place.

This zone type provides a secondary entry delay whenever the zone is faulted ifthe panel is armed in the Away and Stay modes. When the panel is armed in theInstant or Maximum modes, no entry delay is provided. Secondary exit delaybegins whenever the control is armed, regardless of the arming mode selected.These delays are programmable. This zone type is usually assigned to sensors ormntacts on doors through which secondary entry and exit will take place, andwhere more time might be needed to get to and from the console. Delay time mustbe greater than Zone type 1. (Ex.: a garage, loading dock, or basement door)

This zone type gives an instant alarm if the zone is faulted when the panel isarmed in the Away, Stay, Instant or Maximum modes. This zone type is usuallyassigned to all sensors or contacts on exterior doors and windows.

This zone type gives a delayed alarm (using the programmed Entry/exit time) ifthe Entry/Exit zone is faulted first. Otherwise this zone type gives an instantalarm. This zone type is active when the panel is armed in the Away or maximummodes. Maximum mode eliminates the delay though. This zone type Isbypassed automatically when the panel Is armed In the Stay orInstant modes. This zone type is usually assigned to a zone covering an areasuch as a foyer, lobby, or hallway through which one must pass upon entry (Afterfaulting the entry/exit zone to reach the console to disarm the system.) Since thiszone type is designed to provide an instant alarm if the entry/exit zone is notviolated first, it will protect an area in the event an intruder hides on the premisesprior to the system being armed, or gains access to the premises through anunprotected area.This zone type will give an instant alarm if faulted when armed in the Away, Stay,Instant or Maximum (night) modes. During the disarmed state (day), the systemwill provide a latched trouble sounding from the console (and a central stationreport, if desired). This zone type is usually assigned to a zone which contains afoil-protected door or window (such as in a store), or to a zone covering a“sensitive” area such as a stock room, drug supply room, etc. This zone type canalso be used on a sensor or contact in an area where immediate notification of anentry is desired.

-11-

Page 12: ADEMCO manual 4140

Type 0624-hour Went Alarm.

Type 0724-hour Audible Alarm.

Type 0824-hour Auxiliary

Alarm.

Type 09Supewised Fire. (No

Verification)

Type 10interior w/Deiay.

Type 20Arm-Stay*

Type 21Arm=Away*

Type 22Disarm’

Type 23No Aiarm Response

This zone type sends a report to the Central Station but provides no consoledisplay or sounding. This zone type is usually assigned to a zone containing anEmergency button.

This zone type sends a report to the Central Station, and provides an alarm soundat the console, and an audible external alarm. This zone type is usually assignedto a zone that has an Emergency button.

This zone type sends a report to Central Station and provides an alarm sound atthe console. (No beii output is provided). This zone type is usuallyassigned to a zone containing a button for use in personal emergencies, or to azone containing monitoring devices such as water sensors, temperature sensors,etc.

This zone type provides a fire alarm on short circuit and a trouble condition onopen circuit. The beil output will pulse when this zone type is faulted. This zonetype is always active and cannot be bypassed. This zone type can beassigned to any wired zone, but oniy certain wireiess systemszones.

This zone type gives entry delay (using the programmed entry time), if trippedwhen the panel is armed in the Away mode. This zone type is also active duringmaximum mode, but no delay is provided (alarms occur immediately if zone istripped). This zone type is bypassed when the panei is armed in theStay or instant modes. Delay begins whenever sensors in this zone areviolated, regardless of whether or not an entry/exit delay zone was tripped first.

This is a special purpose zone type used with 5800 series wireless pushbutton orcontact closure or opening, and which will result in arming the system in the STAYmode when the zone is activated.

This is a special purpose zone type used with 5800 series wireless pushbutton orcontact closure or opening, and which will result in arming the system in theAWAY mode when the zone is activated.

This is a special purpose zone type used with 5800 series wireless pushbutton orcontact closure or opening, and which will result in disarming the system whenthe zone is activated.

This zone type can be used on a zone when an output relay action is desired, butwith no accompanying alarm (ex. lobby door access).

● Note that these zone types are not for use by 5700 series devices.

NOTE FOR PANiC KEYSKeypad panic zones share the same zone response type for all 8 partitions, butpanics may be individually enabled for each partition.

iMPORTANT! FAULT ANNUNCIATIONPolling loop and RF faults (zones 88-91 & 97) will repori as trouble conditionsonly, and as such, should be assigned either zone type 00 if no annunciation isdesired, or zone type 05 if annunciation as trouble condition is desired. SeeFAULT ANNUNCIATION notes in POLLING LOOP and WiRELESS EXPANSIONsections for more information.

-12-

Page 13: ADEMCO manual 4140

BASIC 9 HARD-WIRED ZONES

Zone 1 Tha fnllatuinfi tshla m }mm a rivae 7nna i fiharaAnrieiber I Iw Ivlwwl! 1~ *UUIW Uu$lll Ila# IAUCI &wl IV I WI mmUWLUI *s#J9wu.

Applications Can be used for EOLR supervised or closed circuitunsupewised devices. It is the only zone that supports2-wire smoke detectors.

Zone Response Type: AnyResponse Time 350 msecMax. Zone Resistance 100 ohms, excluding EOLRUnsupervised Usage ● Cut red PCB jumper.

● Only closed circuit devices can be used.

EOLR Supervised s Leave red PCB jumper intact.● Supports both open circuit and closed circuit devices.● Connect open circuit device in parallel across the loop.

The 2,000 ohm EOLR must be connected across theloop wires at the last device.

● Connect closed circuit device in series with the loop.

EOLR Fire Zone: ● Leave red PCB jumper intact.● Assgn zone type 09 (fire)s Supports up to sixteen (16) 2-wire smoke detectors● Semnd CODE + OFF sequence momentarily

interrupts power to reset the smoke detectors.● See table below for compatible detectors.

Compatible Smoke DetectorsDetector Type Device Model #Photoelectric w/heat sensor, direct wire......................System Sensor 2300TPhotoelectric, direct wire ... ......................................System Sensor 2400Photoelectric w/heat sensor, direct wire......................System Sensor 2400THPhotoelectric w/B401B base .....................................System Sensor 2451Photoelect. w/heat sensor & B401B base....................System Sensor 2451THIonization, direct wire ........ .............. ........................System Sensor 1400Ionization w/B401B base ... ......................................System Sensor 1451Photoelectric duct detectorwA)H400 base .......................................................System Senmr2*lIonization duct detect. w/DH400 base ..................... ...System Sensor 1451DH

Zone 1 AdvisoriesIf the EOLR is not at the end of the loop, the zone is not properly supervised. Thesystem may not respond to an open circuit within the zone.The alarm current provided by this zone is sufficient to supporl operation of onlyone detector in the alarmed state.

UL NOTE: EOLR are required for UL installations.

zone 9 The foliowina table summarizes zone 9 characteristics. 4Applications This zone is unsupervised and is suitable for monitoring

fast acting glass break sensors or vibration sensors whenorormammed for fast resoonse.

Response Type Any type except fireResponse Time Normal (350 msec) or Fast (l Omsec)selected in field ●14.Max. Zone Resistance 300 ohmsUnsupervised Usage ● Only closed circuit devices can be used.

● Connect these devices in series with one anotherbetween terminals 22 & 23.

Zone 9 AdvlsorlesAvoid using mechanical magnetic or relay type contacts in this zone whenprogrammed for fast response.

UL NOTE: The interconnecting wires from zone 9 shall be no longer than 3 feet,with no intervening walls or barriers for UL installations.

-13-

Page 14: ADEMCO manual 4140

—Zones 2-8 t_hefollowing table sur

Applications

Zone Response TypeResponse TimeMax. Zone Resistance

Unsupewised Usage

EOLR Supervised

Glass Break Devceson Zone 8

Smoke Detectorson Zones 2-8

narizes zones 2-8 characteristics.

~

Can be used for EOLR supervised or closed circuitunsupervised devices. Can also support 4-wire smokedetectors. Zone 8 can support Iatchmg glass break

● Zones 1-7:300 ohms, excluding EOLR“ Zone 8: 100 ohms, excluding EOLR

● EOLR disabled in field *41 (enter 1).● Only closed circuit devices can be used.

“ EOLR enabled in field “41 (enter O).● Supports both open circuit and closed circuit devices.● Connect open circuit devices in parallel across the

loop. The 2,000 ohm EOLR must be connectedacross the loop wires et the last device.

s Connect closed circuit devices in series with the loop.

● Supports up to 50 2-wire latching type glass breakdetectors.

● Configure as EOLR zonec Second CODE + OFF sequence momentarily

interrupts power to reset the glass break detectors.“ See table below for compatible detectors..

.

.

.

.

.

Supports as many 4-wire smoke detectors as can bepoweredAssign zone response type 09 (fire).The zones must be configured for EOLR supervision.A normally-closed, momentary switch must be installedin series with the power to the detectors in order toallow reset of the smoke detectors after an alarm.The detectors must be wired in parallel, with the EOLRat the last detector for full supervision.To supervise power, a System Sensor No. A77-716EOL Relay Module is reco-mmended.

Compatible Glass Break DetectorsUse detectors which are compatible with the following ratings:Standby Voltage: 5VDC - 13.8VDCStandby Resistance: Greater than 20k ohms (equivalent resistance of all detectors in

parallel)Alarm Resistance: Less than 1.1k ohms (see note below)Alarm Current: 2mA-10mAReset Time: Less than 6 secondsThe IEI 735L series detectors have been tested and found to be compatible with theseratings. Up to 50 IEI 735L detectors, connected in parallel, may be used (the alarmcurrent provided by this zone is sufficient to support operation of only one detector inalarmed state). Follow the manufacturer’s recommendations on proper installation.Detectors which exceed 1.1k ohms in alarm, but maintain a voltage drop in alarm of lessthan 3.8 volts can also be used.

Zones 2-8 AdvisoriesIf latching type devices are installed on both zones 1 & 8, and these zones areassigned to different partitions, there is a possibility that, if both devices go intoalarm at the same time, the resetting of one device could cause the loss of alarmmemory in the other device.Use of N.O. or N.C. contacts on the same zone may prevent proper glass breakdetector operation.UL NOTE: 4-wire smoke detectors cannot be used in UL installations.

-14-

Page 15: ADEMCO manual 4140

2-WIRE POLLING LOOP EXPANSION (Zones 10 through 87)..- . . . . .. . . . . . . . . . ... ..–––– ,––. ,–—.—–.– .,-.,-

1 11s Iulwwll M mule aulillllarlLua pu IIIf KI WUP WWJW IWUI I w ial auw IWUW

Applications ● Built-in 2-wire polling loop interface allows the number ofzones to be expanded from the basic 9 zones to up to87 zones using various Remote Point Modules (RPMs).See ADVISORIES below.

● The polling bop provides power to sensors and sewesas comnnmication path between the panel and sensors.

“ Refer to the list of compatible devices at the end of thissection.

RPM Address (ID) ● Each sensor must be assigned a unique address IDnumber (from 10-87) before being connected to thepolling loop. Care must be taken to assign unique IDnumbers to each sensor in order to allow the panel tosupervise and provide console status indications forindividual sensors.

● Most RPMs have DIP switches to set their addresses.The 4139SN and 4191SN have preprogrammed serialnumbers which must be “learned” by the control via the#93 menu programming mode.

Connections ● Connect RPM sensors to terminals 24 & 25.● Sensors can be connected to a single run, or groups of

sensors may be connected to separate wire runs withoutaffecting the panel’s ability to supervise individualsensors.

● Follow the wiring instructions provided with individualsensors. Be sure to obsewe sensor polarity when wiring.

● The maximum allowable wire run length between thepanel and the last sensor on a given wire run is shown inthe table below.

Maximum Polling Loop Wire RunsWire Guage Max. Length Note Twisted pair recommended for

#22 gauge 650 feet all normalwire runs.

#20 gauge 950 feet#18 gauge 1500 feet

#16 gauge 2400 feet

IMPORTANT: The maximum combined polling loop run is 4000’. If usingshielded wire, the maximum is 2000’. If longer wire runs are needed, a4197 LoopExtender Module must be used (see instructions included with the 4197).

Intercom Interference If an intercom system is being used, the polling loop wires must be as far from theintercom wiring as possible (minimum 6). If this spacing cannot be achieved,shielded wire must be used. If this is not done, interference on the intercomsystem might occur. Also note that the maximum total wire length supported is cutin half when shielded wire is used.

Advisories The built-in polling loop has two limitations that must be observed. First, themaximum allowable current draw from the polling loop is 64mA. Refer to thePOLLING LOOP CURRENT DRAW WORKSHEET (found in the POWERING THESYSTEM section of this manual) for current draws of various polling loop devices.Second, regardless of current draw, no more than 84 devices can be connectedto this loop. Installations which require up to 87 zones will require the use of4190WH RPMs (which offer 2-points - a rght and a left loop - per device) or theuse of a 4197 (which offers another polling loop supporting an additional64m/V64 points)Make certain to include the total current drawn on the polling loop in theAUXILIARY CURRENT DRAW WORKSHEET (see POWERING THE SYSTEMsection) when figuring the total auxiliary load on the panel’s power supply.

-15-

Page 16: ADEMCO manual 4140

Important! Fault Since the polling loop and the RF receiver(s) are shared among the 8 partitions,Annunciation the scheme for annunciating their failure is as follows:

Respective faults (for zones 88-91 & 97) will report as trouble conditions only, andas such, should be assigned either zone type 00 if no annunciation is desired, orzone type 05 if annunciation as trouble condtiion is desired. If the polling loop or wRF link fails, the corresponding zone number will display a trouble condition foreach partition that uses the device that failed. In additiin, all zones associated withthat device will indicate a fault condition. The trouble condition will not interferewith the ability to arm the partition, but the faults must first be bypassed.

Compatible Poiiing Loop Devices

4208Eight Zone Poiling

Loop ExpansionModule

4190WHTwo Zone Remote

Point Moduie

4278Quad Element Poliing

LooP PIR

4275Duai Eiement Polling

Loop PiR4194

Surface Mounted ReedContact (Wide Gap)

4197Polling Loop Extender

Moduie

4192SDPhotoelectric Poiling

Loop SmokeDetector

4192SDTPhotoelectric Poiling

Loop Smoke Detectorw/Heat Detector

4192CPionization Smoke

Detector4139SN

Auto Smart SurfaceMount Reed Contact

4191SNAuto Smart Recessed

Reed Contact

“ Used to supervise up to 8 hard-wired devices via the polling loop. NOTE: Doesnot support 2-wire smoke detectors.

● Set DIP switches to identify 8 zones.● The first two zones can be either normal or fast response (DIP switch selectable).● All zones are EOLR supervised (first six zones = 4.7k ohms, last two zones =

30k ohms), provided with the 4208.

● Used to supervise 2 hard-wired devices via the polling loop.c DIP switch programmable.● The left zone can be EOLR supervised, if necessary, and can accept either

open or closed circuit sensors, and can be set for fast response. The right zoneis unsupervised and can accept closed circuit sensors only.

s Quad element PIR with built-in RPM which is DIP switch programmable andconnects directly to the polling loop. Includes mirrors for both wide angle andcurtain/long range applications. Features an auxiliary sensor loop that permitsconnection of another nearby closed circuit alarm sensor (reed contact, etc.).

c Dual element PIR with built-in RPM which is DIP switch programmable. Includesmirrors for both wide angle and curtain/long range applications and can use the1875PA Pet Alley mirror. Built-in selectable pulse count capability.

c Wide gap surface mounted reed contact with built-in RPM, which is DIP switch ~programmable.

\

● Can be used if the 2-wire polling loop must be greater than the recommendedlength (4000’ max). By installing a 4197 at the end of the first loop, the pollingloop can be continued. If more than 64mA needs to be drawn from the pollingloop to power RPMs, use of the 4197 provides another loop with 64mAavailable.

● Connects to the polling loop and is powered from auxiliary power or by aseparate 729 power supply with battery backup.

“ One piece photoelectric smoke detector with built-in RPM which is DIP switchprogrammable.

● One piece photoelectric smoke detector with 1350F (57°C) heat detector, andbuitt-in RPM which is DIP switch programmable,

● One piece products of combustion ionization detector with built-in RPM which isDIP switch programmable.

● Compact surface mount magnetic reed contact with built-in RPM.● Serial number ID “learned” by control panel.● Check product availability,

● Recessed (1/2” dia.) magnetic reed contact with built-in RPM.● Serial number ID “learned” by control panel.● Check product availability.

-16-

Page 17: ADEMCO manual 4140

WIR~LMS RXPANSION (Zones 1=63)

Oonwal Information[Rooolvm’a)

TransmJttcrs Supportedbv varloua rocolversRoe.ivor 714280 6%

4281M 84281L 4S881H 84S881M 16

eQni

I’hefoliowlng tablestones Supported

~FRsoeivers(Qenord

Receiver Supervision

House Identification

Sniffer Mode ForHouse Id(Code + [#]+ [2])

rwnarizeswireless exBan8ionoharaoterlstios.c The 8ystem supports up to 83 wireless transmitters

(5700 or 5800 series), plus a wireless keypad.BTo expand the system using wireless, one or two of the

same type of RF Reoelvers can be used.~ Any zone from 1-83 can be used as a 5700 aerie8

wireless zone. The total number of trarwmlttereSUPPCNW byeach reoelver Is shown In the transmittedsupportedtable. Any zone from 1=87 can be used asa5800 serieswirelesszone.The 4140XMPT2 supports the 4280, 4281 and 5881series RF reoelvere. Refer to the transmitters auppottedta:av:r the number of zones supported by each

The receivers respond to status and alarm signals fromwkeleee transmitters (@345MHz USA; 315MHz Canada)within a nominai range of 200 feet, and reiay thisinformation to the oontroi,Two of the same type of receivers can be used toprovide either a greater area of coverage, or to provideredundant protection, The type of receiver used isidentified in program field 1’32,Receivers must be mounted externally to the controi,The 4280 & 4280-8 receivers are connected to thepoliing loop.The 4281 and 5881 series receivers are connected tothe consoie data iines.

9

9

if the connection is broken between the receiver and thecontroi panel, a TROUBLE wili be dispiayed for zones 89or 91 (if type 05 is assigned). in addition, aii zonesassociated with the RF device will report a troublecondition.If, within a programmed intervai of time, the receiver doesnot hear from any of its transmitters, a TROUBLE wiiiappear for zones 88 or 90 (if type 05 is assgned).4280 oniy: if the cover of the 4280 is removed, aTROUBLE wiil be dispiayed for zones 89 or 91 (if type 05is assiqned).

● Receivers respond oniy to transmitters set to the samehouse iD (01-31). This prevents system interferencefrom transmitters in other nearby systems.

c Use Sniffer Mode (described later) to make sure you donot choose a House ID that is in use in a nearby system.

● 4280 house ID is set via DiP switches.● 4281/5881 (for 5827) house iD is programmed via #93

Menu Mode, Device Programming..

9

To check for house iDs being used in nearby systems,set the receiver’s House iD to “00”, then enter your“Instailer Code”+ [#]+ [2]The receiver will now “sniff” out any House iDs in the areaand display them. Keeping the receiver in this mode forabout 2 hours wiii give a good indication of the house IDsbeing used. To exit the Sniffer Mode, simpiy key yourinstailer code + OFF, then set your house iD to onenotdispiayed in the “Sniffer Mode”.Important: Since Sniffer Mode effectively disabies RFpoint reception, Sniffer Mode cannot be entered whiieany partition is armed.

-17-

Page 18: ADEMCO manual 4140

-.. –... .. . . . . . . . .. . . . . . .

4280 8erles Receiver

4280 is not recommendedfor new installation; receiveris scheduled to bediscontinued.

4281 8erke Receiver

5881 8eriee Receiver

House ID

Receiver Address

Cover Removal

Go/NoGoMode

Spatial Diversity

Transmitter ID

4280 series

Connects to pollingloop

set via D1Pswitches

Set by cutting bluelumper in 2ndreceiver. Enabledvia fields 1“26 &1●27.

Causes alarm ortrouble dependingon response typeassigned.

Requires coverremoval.

No. Requires 2receivers forredundancy or toexpand area ofcoverage.

Set via DIPswitches.

4281 series I 5881 series1

Connects toconsole lines

programmed via #93 programmed via #93Menu Mode. Menu Mode.

Set via DIPswitches.Enabledvia #93 DeviceProgramming.

Does-not causealarm or trouble.

Set via DIPswitches. Enabledvia #93 DeviceProgramming.

Does not causealarm or trouble.

Automatic uponentering test mode.

Yes. Eliminatesnulls and voids. 2ndreceiver expandscoverage area orprovides additionalredundancy.

Set via DIPswitches.

Automatic uponentering test mode.

Yes. Eliminatesnulls and voids. 2ndreceiver expandscoverage area orprovides additkmalredundancy.

Serial numbers are“learned” by thesystem.

.

.●

lm~ortant: Note that if usirw two RF Receivers, one of them must bepowered from auxiliary power; so as not to exceed the 64mA polling loopcurrent rating.Set field 1*32 to O.

For more information regarding the 4280 installation, refer to the installation-

instructions provided with the 4280.If using a 4280-8, only up to 8 zones can be enabled as RF zones. If more than8 zones are enabled, the message “SET-UP ERROR” (or E8 on non-alphaconsoles) will be displayed.Refer to the maximum polling loop wire runs described in the POLLING LOOPsection when connecting 4280s to the polling loop.IMPORTANT: The maximum combined polling loop run is 4000’. If usingshielded wire, the maximum is 2000.

Set field 1*32 to 1.Using #93 Menu mode-Device Programming, select as RF device type.Set house ID via #93 Menu Mode.Set receiver% device address using its DIP switches. Lower numberedaddress is primary receiver (supervisory fault ID 90, 91). Higher numberedaddress is secondary receiver (receiver fautt ID 88, 89).Important: 4281 microprocessor must have part number N5334VX, where x isany number. The microprocessor is located just above the DIP switch on thePC board.

Set field 1*32 to 2.Using #93 Menu mode-Device Programming, select as RF device type.Set house ID via #93 Menu Mode (needed for 5827 keypad only).Set receivets device address using its DIP switches. Lower numberedaddress is primary receiver (supervisory fault ID 90, 91). Higher numberedaddress is secondary receiver (receiver fault ID 88, 89).

v

-18-

Page 19: ADEMCO manual 4140

Transmitters

NOTE: After replacing a bwor dead battery, activate the

transmitter and enter thesecurity code + OFF to clear

its memory of the “LowBattery” signal.

I w I Wllww II w LauIw WJI I u Ilal Kwu wvuUIUW u m m IIILK71 u IaIaULWI I=L*O.

‘transmitters(Generel) ● Supports 5700 or 5800 series transmitters.● Each transmitter has its own unique transmitter ID

number (Zone #). 5700 series transmitters use DIPswitches to set the ID. 5800 series transmitters musthave their ID nurrbers “learned” by the system.

● 5700 series transmitters and the 5827 keypad must alsobe set for a house ID. Other 5800 series transmittershave built-in serial numbers and do not require a houseID to be set. After installation, check that all transmittershave been assigned the proper house ID by using theprocedure described later.

‘rans. SupervWlon ● Each transmitter (except 5701, 5727, 5802, 5802CP &5803) is supervised by a check-in signal that is sent tothe receiver at 70-90 minute intervals. If at least oneCheck-in is not received from a transmitter within aprogrammed interval (field 1*31), the console will displaythe transmitter number and “CHECK” will be displayed.

● Each transmitter (including 5701; 5727, 5802, 5802CP&5803) is also supervised for low battery conditions, andwill transmit a low battery signal to the receiver when thebattery has approximately 30 days of life remaining. Theconsole will display the transmitter number and “LOBAT”.

;800 Series “Learn” ● 5800 series transmitters have built-in serial numbers thatmust be “learned” by the system during programming.Refer to the PROGRAMMING GUIDE for details.

:hecking Trans. ● To check that all transmitters have been set property,>peration including set the receiver to the proper house ID)IP & serial number and enter the Installer code + [#]+ [3].Code + [#]+ [3]) ● All transmitters that have been enabled for the partition in

which the test was initiated will be displayed. As eachtransmitter checks in (up to 2 hours), its ID number willdisappear. A faster way to do this is to fault eachtransmitter, which causes a transmission to be sent to thereceiver. When all transmitters have checked in, thereshould be no ID numbers displayed.

● NOTE: Repeat this procedure for each parlition that usesRF transmitters.

‘Go/No Go” Test ● This mode helps determine the best location for eachulode (Patented) transmitter and is activated by putting the control panel in

the TEST mode (4280 requires removing the its cover).c The receiver’s sensitivity is reduced by half. Once

transmitters are placed in their desired locations and theapproximate length of wire to be run to sensors isconnected to the transmitter’s screw terminals, opencircuit each transmitter. Do not conduct this test with youfhand wrapped around the transmitter.

● If a single receiver is used, the console will beep threetimes to indicate signal reception. If two receivers areused, the console will beep once if the first receiverreceived the signal, twice if the second receiver receivedthe sgnal and three times if both receivers heard thesignal (which is desirable for redundant configurations).

● If the console does not beep, reorient or move thetransmitter to another location. Usually a few inches ineither direction is all that is required.

● To exit this mode, enter the installer code and pressOFF (replace the 4280s cover). Note that the Receiver’ssensitivity is fully restored when this mode is exited.

-19-

Page 20: ADEMCO manual 4140

Note On RF Keys 5800 series RF keys can be used to arm and disarm the system. These(5801, S803, etc.) transmitters include the 5801, 5803, and any other 5800 series transmitter if

programmed for one of zone type responses 20-22. These transmitters are tied ,to a user in order to provide a record of who armed or disarmed the system.Because of this, an RF button will not armor disarm a system unless it has been wassigned to a user, which is done during the “add a user” function (see Add AUser Code section). In addition, when the user is deleted from the system, thekey is deactivated. To test whether the keys are assigned to users or not, use thetest mode. When the appropriate button is pressed, the corresponding zone willbe displayed on the console and will remain there until test mode is terminated.

Wirelees Zone Types Each RF zone can be programmed to respond as any zone type such asENTRY/EXIT, INTERIOR, PERIMETER, etc. (see the ZONE TYPES section for acomplete explanation of each zone type).

Desired alarm responses for 5700 series devices are as follows:ZONE TYPE TRANSMITTER ID #Entry/Exit Burg 1through 47 *Perimeter Burg 1 through 47 ●

Interior Burg 1 through 47 ●

32 through 47 * (5775)Fire 46 through 63 ●

48 through 55 “’ (5706)

24 Hour Panic 46 through 63*(silent or audible) 62 or 63 ●** (5701)

Day/Night Burglary 1 through 47 ●

24 Hour Auxiliary 1 through 47 *

NOTES:● Note that zones 1-63 can be used, but have the following limitations: Transmitters set

for zones 48-55 will transmit once every 12 seconds while the zone is faulted.Transmitters set for zones 56-63 will transmit once every 3 seconds while faulted.These two ranges of zone numbers could adversely affect transmitter battery life.Transmitters set for an ID of 32 through 47 will have a 3 minute lock-out between *transmissions. Use this last range of zone ID numbers for sensors protectingfrequently used doors or windows to conserve battery life.

** Transmitter IDs 48 through 55 have highest signal priority.*•* Transmitter IDs 62 and 63 are unsupervised to allow removal of the 5701 off premises

.- signal prioriiy is lower than that of fire, but higher than burglary.

Advlsorles 1. Do not place transmitters on or near metal objects. This will decrease rangeand/or block transmissions.

2. Place the receiver in a high, centrally located area for best reception. Do notplace receiver on or near metal objects.

3. For maximum range, the RF receiver must be at least 10 feet from the Controlpanel or any remote consoles to avoid intederence from their microprocessor.UL NOTE: For UL Household Burglary Installations, wired loopsconnected to these devices cannot exceed 3 feet.

4. If dual receivers are used:A. Both must be at least 10 feet from each other, as well as from the Control

panel and remote consoles.B. The house IDs must be the same.C. Using two Receivers does not increase the number of transmitters the

system can suppofi (83 transmitters, plus a wireless keypad).

Fault Annunciation Since the polling loop and the RF receiver(s) are shared among the 8 partitions,the scheme for annunciating their failure is as follows:Respective faults (for zones 88-91 & 97) will report as trouble conditions only, andas such, should be assigned either zone type 00 if no annunciation is desired, orzone type 05 if annunciation as trouble condition is desired. If the polling loop orRF link fails, the corresponding zone number will display a trouble condition foreach partition that uses the device that failed, In addition, all zones associated withthat device will indicate a fault condition. The trouble condition will not interfere ~with the ability to arm the parlition, but the faults must first be bypassed.

NOTE: 5800 series transmitters have built-in tamper protection and willannunciate as a “CHECK” condition unless field ●24 is disabled.

-20-

Page 21: ADEMCO manual 4140

Important Battery The wireless transmitters are designed to provide long battery life under normalNotice operating conditions. Longevity of batteries may be as much as 4-7 years

depending on the environment, usage, and the specific wireless device beingused. External factors such as humidity, high or low temperatures, as well as largeswings in temperature may all reduce the actual battety life in a given installatbn.The wireless system can identify a true low battery situation, thus albwing thedealer or user of the system time to arrange a change of battery and maintainprotection for that given point within the system.Button type transmitters should be periodically tested by the installer for batterylife (5701, 5802, 5602CP & 5603).

Compatible 5700 Serlea Wireless Devices

5701Panic Transmitter

5711Sllmllne Door/Window

Transmitter

5711WMDoor/Window

Transmitter w/FteedSwitch

5715WHUnlversai Transmitter

5727Wlreiess Keypad

5716Door/Window

Transmitter

5775Wireiess PiR

5706Wireless Photoelectric

Smoke Detector(System Sensor)

5707Wlreiess PhotoelectricSmoke Detector (ESL)

● Programmable for either silent or audible 24 hour alarm (can be DIP switchprogrammed for zones 62 or 63).

● Can be used with any cbsed circuit sensor. Can be used on any zone 1-63 but,if set for zones 3247, there wiil be a 3 minute lock-out between transmissions.

● Slimline door/window transmitter with built-in reed switch (magnet included).Can be used with any closed circuit sensor. Can be used on any zone 1-63but, if set for zones 32-47, there will be a 3 minute lock-out betweentransmissions.

● DIP switch selectable for fast response, open or closed circuit sensor usage,and has a tamper protected cover. Use in applications where open circuit heatdetectors are needed or where fast response devices are needed. Can beused on any zone 1-63 but, if set for zones 32-47, there will be a 3 minute bck-out between transmissions.

● Wireless keypad that can be used to turn the burglary protection on and off,and features the same built-in panic functions as wired consoies for either silentor audible 24 hour alarm. An LED indication lights each time a key is pressed toverify transmission (LED located in the [Q] READY key).

● The keypad is identified as zone “00” when it transmits low battery messages.The keypad panics are identified in the same way as wired console keypadpanics (i.e. 95, 96& 99).

● Can be used with any open or ciosed circuit sensor (DIP switch selectable), andfeatures a built-in reed switch. Can be used on any zone 1-63 but, if set forzones 32-47, there wiil be a 3 minute lock-out between transmissions.

● The 5775 is a battery operated, wireless, dual element passive infrared motiondetector with built-in selectable pulse count, that can be monitored by a 4280(4280-8) wireless receiver, and is DIP switch programmable for zones 32-47.NOTE: There is a 3 minute lock-out between transmissions to preserve batterylife.

c One piece smoke detector with built-in transmitter (DIP switch programmable forzones 48-55). Built-in UL Listed 85 dB piezoelectric alarm sounder and audibleiow battery warning.

● One piece, dual battery smoke detector with built-in transmitter (DIP switchprogrammable for zones 48-55). Built-in UL Listed 85 dB piezoelectric alarmsounder and audible low battery warning.

-21-

Page 22: ADEMCO manual 4140

Campstlble 5800 Berles WIrekee Devices

58014=Button Transmitter

5802Pendant Panic

Transmitter

5802CPBelt Clip Panic

Transmitter

58033-Button Transmitter

5806Photoelectric Smoke

Detector

5807Photoelectric Smoke

Detector

5816Mlnlature Transmitter

58173-Point Transmitter

5827Wireless Keypad

5849Giass Break Detector

5890Dual Element PIR

● Four button hand held or wall mount transmitter.s Programmable functions● Includes one 466 battery

● Single button actionc Press and hokf to avoid accidental alarms● waterproof (sealed battery)

● Single button action● Press and hold to avoid accidental alarms“ waterproof (sealed battery)

● Three button “key”● Programmable functions● Sealed battery

● Includes two 9 votf alkaline batteries (464)“ Optional tamper protection

● Includes two 9 volt alkaline batteries (464)

s NO/NC Ui~bliiiyBuilt-in reed contact

● Tamper● Includes one 3 volt lithium battery (466)

● Accepts 3 switches with 3 different addresses● NO/NC capability● Tampers Includes one 3 volt lithium battery (466)

‘ Use handheld or wall mounted● Provides almost oornplete system control capabilityc Raised dome keys and led for positive operation● No. 5634 belt clip available● Includes one 9 volt battery (464)

s Audio discriminator plus shock sensor● Tamper● Inoludes two 3 volt lithium batteries (466)

● Interchangeable lenses: long range, etc.● Built-in transmitter with battery saver circuit● 40’ wide angle pattern● Tamper● Includes two 3 volt lithium batteries (466)

-22-

Page 23: ADEMCO manual 4140

VOLTAGE TRIGGERS (Connector J7)(Ground Start Module, Keyswitch, Remote Console Sounder)

General Information Connector J7, located on the right hand side of the main PCB provides 4 triggeroutputs for operating the 675 Ground Start Module, the 4146 Keyswitch, aremote console sounding piezo, and for triggering auxiliary alarm signalingequipment (such as the 7720 and 7920SE LORRA Subscriber Radios). Note thatthese output triggers can be enabled by partition via programming field 2*20.The pin assignments of this connector are shown below. Use only the 4142TR9-wire cable (available as an option) for making connections to this connector,

output 1

J7 CUNNCCTON

outputs 2 & 4

OUT !: GROUNO START OR OPENJCLOSEOUT 2. FIRE OR KEYSWITCH ARMED LEOOUT 3. BURGLAtW/AUOISLE PANIc/AuxILIARYOUT 4; SILENT PANICIOURESS OR KEYSWITCH READY LEO

Output 2,3 &4 Rating:

Ground Start Module

Not intended for use InUL Listed anplicatlons.

Operates, by default, as a trigger for the 675 groundstart module. This output may optionally beprogrammed to operate as an operdclose trigger or as aremote console sounder output. Only one of theseoptions may be used at any time.Rating: When Activated: 10 -13.8 VDC through 4Kohms

(2.5MA max)When De-activated: 100 ohms to ground

Operate, by default, as Fire and Silent Panic/Duresstriggers respectively. These triggers may optionally beprogrammed to act as Arm and Ready status indicatorswhen it is desired to use the 4146 keyswitch.

When Activated: 10- 13.8 VDC through 5K ohms(2MA max)When De-activated: 1k ohms to ground

An optional 675 Ground Start module can be used for installations havingtelephone lines which require ground start instead of loop start operation toobtain dial tone from the telco central office.If used, program field 1●46 must be set to “O” (factory default) and the 675Ground Starl Module must be connected to the panel’s J7 connector triggeroutput 1, to auxiliary power, and to the “RING” side of the telephone line asshown in the diagram below.Use the following procedure to determine which side of the telephone line is the“RING side:

a. Connect the “+” lead of a DC voltmeter to earth ground, and the “-” lead toone side of the telephone line.

b. The wire which reads +50VDC is the “RING” side,When the panel has a message to transmit to the central station, it will seize theline, go off hook, and then trigger the 675 module to connect the “RING” side ofthe telephone line to earth ground. The panel will cause the module to break theconnection between “RING” and earth ground when a dial tone is obtained.

4147TR CALIIJ .17 C0NNEl,70ne, 1

‘Q%+b :0”mTouNO STARTTRIGGER GnAY

.

47$ 71LUE Q+,

OROuNoSTAR

YELLOW.

MODU.. —–—BLACK “+0TERMINAL r

(CUT QUANGE

-i+

WHITEJUMPER) %.

.

$ $

RT,, . ~ TO AUXPOWER -

~40,

l+#~::~g::;ORAw‘:O:N :To TELCO To EARTH

RING GROUND1) OUT 1 IS NO LONGER

USABLE FOR OPEWCLOSE

Hi

BROWN

!SEE FIELD 1, 46). Q90 .

2) OUT 2,3,4 CAN STILL BE %0uSED TO PROVIDE ALARM BLUESTATUS INDICATIONS OR

%,e

TO OPERATE A KEYSWITCH(SEE FIELD 15).

,

3) THE 675 IS NOT UL LISTED BLACKm

-23-

Page 24: ADEMCO manual 4140

Remote Keyswitch If the keyswitch option is selected (field ●15), the alarm trigger outputs aredisabled.

An optional Remote Keyswitch can be used for remote arming and disarming ofthe system. Note that keyswitch arming may only be used in one ~

E ‘artiti”n”If used, program field ●15 must be set to the desired partition to enable thekeyswitch option, and the4146 keyswitch’s normally open momentary switch andLEDs must be connected to Zone 7 and to the J7 connector trigger outputsrespectively. A 2k EOL resistor must be connected across the switch regardlessof whether or not zones 2-8 are selected to use EOL resistors. See diagrambelow.Note that the system automatically assigns zone type 10 to zone 7 if keyswitch isused.A momentary short across this zone will arm the system in the “AWAY” mode. Ifthe short is held for more than 3 seconds, the system will arm in the “STAY”mode. (i.e. all zones designated as zone types 4 or 10 will be automaticallybypassed). After the system has been armed, the next time zone 7 is shorted,the system will disarm.An optional closed-circuit tamper switch (model 112) can be wired in series withzone 7, so that, if the switchplate is removed from the wall, the tamper wiil open,disabling keyswitch operation until the system is next disarmed from the console.Note: Only one keyswitch with LEDs can be supported by the system’s

power supply.Note: Open/close reporting for keyswitch is enabled in field ’40, and the

keyswitch reports as user O.LED indications are defined as follows:Green Red Meaningoff off Disarmed & Not ReadyOn off Disarmed & Readyoff On Steady Armed Away *off Slow Flash Armed Stay

off Rapid Flash Alarm Memory

i f I II i 2 3A 567 8 9

—l——r ~--TO AUX POWERTERMINAL 6

IF KEYSWITCH IS USEO.1] OUT 1 CAN STILL BE USED TO PROVIDE

GROuND START, OPENicLOsE {SEE FIELD I. 46}.2) OUT 2,3,4 NO LONGER PROVIDE ALARM

STATUS lNOICATIONS OUT 2 & 4 OPERATEKEYsWITCH LEDs OUT 3 IS NOT USED.ONLY 1 KEYSWITCH CAN BE USEO.

3) ZONE 7 IS NO LONGER USA6LE AS ,4PROTECTIVE ZONE.

TO ZONE 7

TO TERM. 20

s

14TO TERM 19

BROKEN LINES REPRESENTINSTALLER WIRING CONNECTIONS

m

I(Ii

“-*’20”1-.—.——.—-———--—-—TAMPER

SWITCN IN. C.)

--—. -- 63!--—LOCK

SWITCH IN 0.)I

o

I

---- --++---;

I 1----I 2000

I OHMS

L------ $

EOLR

--

-24-

1 14146 KEYSWITCH(NOT UL LISTED)

Page 25: ADEMCO manual 4140

Remote Console An optional Amseco PAL 328N can be used for installations where it is desired toSounder Operation & remote the sounds produced by the console’s built-in piezo sounder for one

Wlrlng partition. The panel will remote all sounds (Le. alarm, trouble, chime, entry/exit,etc.) produced by the console’s built-in sounder except for the short clicksassociated with console key depression. One applicatbn of this feature might beto produce chime sounds in a bcation which is distant from the panel’s consoles.This can also be accomplished using relay outputs (see Output Relay section).

If used, program field 1●46 must be set to “2” to enable the remote consolesounder option, and the Amseco piezo must be connected between the panel’sauxiliary power and the J7 connector trigger output as shown below.

In addition, field ●15 must be used to select the partition whose console soundsare to trigger the sounder. Zone 7 must be assigned to be a keyswitch zone(even if keyswitch is not used).

414ZTU GAULEIF USED, — J?CONNECTOR1) ~:LUF~mLONQER

OPEN/CLDSEORQROUNDSTART(SEEFIELD1’46).

2) OUT 2,3,4 CAMSTILLBE

r

L?(ACKUSEDTO PROVIOEALARMSTATUSiNDlCA-TIONSOR TO OPERATE —

A KEYSWITCH(SEEFIELO“16). AMSEOOPAL-3

PIEZOSOUNOE

+

TO AUX POWER+TERMINALS(lOmA CURRENTORAW) d

f15%A%ll

EE13YELLOW

~~ ~“IE ●

>12SN IIEDER

4 GREEN..

-25-

Page 26: ADEMCO manual 4140

OUTPUT CONTROL (4204 Relay Module/X-l O Devices)

General Information The 4140XMPT2 suppotts up to 16 relay outputs. These outputs may consist ofrelay outputs from the 4204 output relay module (4 relay outputs per module) orX-1 O device outputs. Outputs can be activated and deactivated by spredetermined events such as turning on lights in the event of an alarm conditionartdor closing a fire door in the event of a fire alarm condition. Refer to thePROGRAMMING GUIDE for instructions on programming relay options.

There are many different uses for relays, some of which are shown at the end ofthis section.

4204 Relay Module The 4204 Relay Module has 4 form C (normally open and normally closedcontacts) relays. Each relay can be used independently for different functions.The 4204 is wired to the control’s console terminals 6-9. Use standard 4-conductor twisted cable (for long wire runs) or the connector supplied with the4204. Each 4204 should be home run back to the panel, The maximum wire runlength from the panel to the 4204 must not exceed:Wire Guage Maximum Length#22 125 feet#20 200 feet#18 300 feet#16 500 feet

The 4204’s DIP switch must be set for a device address and that address must beenabled in the control’s Device Programming mode. (Note that some early unitshave only 4 DIP switches,)Program the output relays using the control’s *93 Menu Mode. Refer to thePROGRAMMING GUIDE for details,

4300 Transformer & When using X-1O devices, the 4300 transformer must be used Instead of theX-1 O Devices 1361 transformer shown on the Summary of Connections diagram. The 4300

provides AC power to the panel and rela~s signals from the p=nel through thepremises AC wiring to X-1Odevices. *

Run a 3-conductor cable between the 4300 interface and the panel. Splice thiscable to a 4142TR cable as shown in the diagram below. Note that the white andyellow wires of the 4142TR must be spliced together.

X-1Odevices plug into standard AC outlets and can be used to perform variousfunctions. Be sure to set the proper house and unit IDs when using X-1Odevices.

UL NOTE: X-1O devices and the 4300 are not UL Listed for fire or burglatyfunctions and are intended for home automation.

DO TRANSFORMEWINTERFAC

OJIu

ml ml ml-1 40 -2

:Datn C.xn

Ii

56

I I

I

J8 CONNECTOR

~ 4142TR CASLE

-26-

Page 27: ADEMCO manual 4140

~XAMPLRS OF USES FOR RSLAYSThe followlng table Ilate examples of some possible usee for rolaym Refsr to the Relay Programmingsection of the PROGRAMMING GUIDE for detailedInformation,

~18T OF START ~~~~i &$klR9q0Wl”ld0eefor2~2doMand9 hydoaad; 2sPuieeonarldoff

AND STOP ZLmZON#LMM40t Ueed;harm’ 2hUit;3=TroWle’4=ReetofQ

1to8 tiFti*~l)wO=Nti-, ~@nwwddlm*m RE_Ed=E

CHOICES L18T,~-Milk. ktimt@-lMmtiWSTA~

27 BZono7y@yMelll Operatfolr

OholeeeForZoneTypesAm:00. NoReepofw 02=24 Hr8Uent

01mEntrytaxit 07=24 HrAudibla03= Porknmr 02=24 HrAux04= InteriorFollow 0S9 pin02- TroubkDwAlamr Night 10= Mm&rw/Delay

OhofonForeysternoperation;20¤Arming-Stay 32=FireZorw7roubie21=Atmlno-Away 40.ay~

22¤ Dlearmin2 41=ACPow Failure

31= EndofExitTime 42= Sy8WllhWyi.OW32= Startof En8yThe 42= OommuniodonFalluru

33= Any2urg@ Alarm 44. RFLowEatwry

34=ooda+#+7+l 46= PollingLoopFailure33= Code+#+7+2 61 = RFReceiver f%ih

33= At~li ‘f’iMOOUt’** 52. Xiaaoff

37.2 Times Bell Timeour” 34= FireZoneResetw w●*Chlm@ Ss. ouluee

‘Should beuaedtoctwt2~d doeeofru&yonty●“Or at Diurming,WhioheveroooureearfierAddltlond StopCholooe:3S=Diaarm+l Mhwteas= X%tdinutae(EnterXXat 1*74)

67= WSeocndE(EnterYYat1“7S)

STARTACTION DESIRED

Close relay at start of entry time and reset with key entry of 2 0 0 32 xseourity code+ # + 7+1 ●

Close relay at start of entry time and reset after 1 minute 2 0 0 32 x

Close relay after any burglary alarm and reset with key 2 0 0 33 xentry of security code + # + 7 + 2.**

●*Can be used to turn on lights in the event of a burglaryalarm...(NOTE: Response types 06, 08, and 09 will notactivate relay).

Turn All Lights off with entry of security code+ # + 7 +2* 2 0 0 00 x

*Can be used to turn off all lights in on agiven X-10 Houseand Unit Id

Pulse light on trouble oondition to attract attention_ 3 3 x 00 x

Puise Light on alarm to attract attention_ 3 1 x 00 x

Use a PIR to turn a light on for a pre-set time period_ 2 2 x 00 x

STOP

o 34 x

o 55 xo 35 x

o 35 x

o 22 xo 22 xo 56 x

-27-

Page 28: ADEMCO manual 4140

ACTION DESIRED

=You must define a Stati zone list (z/) for theseapplications to work properly.

●Can be used to turn on lights in a specific room or area.For example you can automatically turn on the basement/ight on entry.

CHIME

Close relay for 2 seconds during chime. (Chime mode 1must be turned on at control)

Chime on Specific zones:

gdri~i~qz~~i~;(%j @W,~$&yfO~~,S~@$ ~{g~~itiq~j $,i:::..,,.,,,..“Will activate relay for any zone type plus panics on 5601whether control is armed or disarmed. (Console panics willnot activate a relay with the configurations above.)

Zones in zone list (x) close relay for 2 seconds on alarms 1

Zones in zone list (x) close relay for 2 seconds on troubles 1

Close relay after any burglary alarm and reset at bell 2timeout or when disarmed by any partition.

*Response types 06,08, and 09 wi// not activate re/ay. /fPULSE relav is desired, enter a 3 in A(actionl.

Zones in zone list (x) pulse a relay after alarms and reset ]3when disarmed by either parltion.” I

Close relay when ARMED-AWAY, reset when 2DISARMED. (Any partition)*

Close relay when ARMED-STAY, reset when DISARMED. 2(Any ~artition)’

‘If PULSED relay is desired, enter a 3 in A(action).

Bypassing a zone causes relay to close and will reset with 2a disarm sequence (code+ off.)

CONFIRMATION OF ARMING DING I

Close relay for 2 seconds at end of exit delay time afterI

1system is armed

START

28 -

Page 29: ADEMCO manual 4140

START STOPACTION DESIRED A EV ZL ZT P ZL ZT P

UNLOCK EXIT DOORS

Close relay on Burg alarm, reset with entry of security 2 1 x 33 x x 34 x00de+#+7+l

Close relay on Fire alarm, reset with entry of seourity code 2 1 x 09 x x 34 x+#+7+1,,,,,.,,,.,,,.,.,,,.,.,.,.,,,.,,,,,.,,,.,,,,,............................... ....................................................................................................................................................................

:%MRwMm;EMMM#MRwIMtMMxlMwHHmwm: Mg: =% ~~ g~g MM =$ ;@@@ ~~$...........}..

An AC loss detection causes relay to close for 2 1 0 0 41 x o 00 xseconds.*

“The re/ay wi//not reset on restora/ of /ow batte~ orACpower. For this reason, using “close for 2 seoonds” inA(action) is recommended.

............................................................................‘:%gwMwMm#&iwEww#Rg#%m#RwM ;@@& g~g~m, jm% m~ g~ ~~$ m;,::::.,,,.,., ........... .,,,,,,,,,,,.,. .,,,..,,.,.,.Pulse relay at start of entry time and reset when system is 3 0 0 32 x o 22 xdisarmed (entry warning)’

“Relay oan be used to turn on an external sounder placedwhere it can be head by someone using the wirelesskeypad.

-29-

Page 30: ADEMCO manual 4140

General

4137AD AddressableFixed-Word Console

5137AD AddressableAlpha Console

6139 DeluxeAddressable Alpha

Console

The Control supplies up to 750 mA of auxiliary power for remote consoles, pollingloop devices and/or other auxiliary devices such as motion detectors or 4-wiresmoke detectors*.The Controls support, independent of auxiliary power considerations, up to 16addressable remote consoles (4137AD, 5137AD, 6139).

Up to twelve (12) 4137AD or eight (8) 5137AD or seven (7) 6139 consoles canbe powered from the auxiliary power output provided that the total current drawnfrom this output does not exceed 750 mA. Keep this in mind when addingremote consoles so you don’t overdraw current from the panel. This woukf resultin a battery which does not charge properly or possibly a tripped auxiliary solidstate circuit breaker.

If the auxiliary load is determined to be greater than 750 mA, then additionalconsoles can be powered from a separate power supply. Refer to thePOWERING ADDITIONAL CONSOLES paragraph for a diagram that shows howto make connections to the separate power supply.● 4-wire smoke detectors cannot be used in UL Listed applications.

Equipped with a liquid crystal display (LCD) using 2-digit numerics for zoneidentification, and a set of pre-designated English language prompts, such as“READY”, “NOT READY”, etc. for system status. Keys are backlit. A built-in alarmsounder is also included, eliminating the need for a separate indoor sounder. DIPswitch selectable ID number, which allows console to display status of thepartition to which it is assigned. 60mA current draw. -

Equipped with a programmable 2-Iine, 32-character (16 characters per line),backlit alphanumeric LCD for complete zone identification in English language (ifdescriptors are programmed). Keys are also backlit.An alarm sounder is built in, eliminating the need for a separate indoor sounder.DIP switch selectable ID number, which allows console to display status of thepartition to which it is assigned.90mA current draw.

The 6139 Remote Consoles are keypad addressable (no DIP switches) console,and features a red “ARMED LED which lights when the system is anneal,and agreen “READY” LED* which lights when the system is ready to be armed (nozone faults present). This console also features display backlighting. The keypadon this console is located behind a decorative door, and is continuously backlit forease in use. The keypad also features special panic keys, labeled A, B, & C (theD key is not used), which are the equivalent to the panic pairs of keys l/Q, Q/#, &3/# respectively. Note that these keys must be held down for at least 2 secondsto activate an alarm.

* Note that the function of this LED (system ready)differs from the function of thegreen LED on Ademco’s4137AD & 5137AD consoles.

The console can be surface mounted directly to a drywall, or to a single or doublegang electrical box. For flush mounting to drywall, use the optional6139TRKflush mount kit.100mA current draw.

-30-

Page 31: ADEMCO manual 4140

Programming TheConsoies

Mounting TheConsoies

Wiring Consoies

Powering AdditionalConsoies

The consoles can beset for an address of 0-30

iMPORTANT! You must select an address of O, 1, 2, or 3 if standard defaultsare to be programmed, since these are the only console addresses enabled bythe standard default. Refer to the addressable console DIP switch table at theend of this manual to set the 4137AD and 5137AD address ID number. Refer tothe instructions provided with the 6139 to set its ID number.

Do not use address 31 with the 4140XMPT2. Address 31 causes theconsole to operate in non-addressable mode (i.e. works like a standard, non-addressable console).Consoles must also be programmed for type, partition number and consolesounder suppression options. Refer to the PROGRAMMING GUIDE (#93 MENUMODE-DEVICE PROGRAMMING) for instructions.

Note that fiekf wiring to the consoles must be completed before the consoles canbe mounted.The consoles can be either surface mounted or flush mounted (using anappropriate Trim Ring Kit: 5137TRK or 6139TRK). Refer to the mountinginstructions and template included with the console and/or trim ring kti for specificinformation.Be sure to take the height of the users into account when mounting consoles.

Consoles may be wired to a single wire run or individual consoles may beconnected to separate wire runs. The maximum wire run length from the panel toa console which is homerun back to the panel must not exceed:

Wire Guage Maximum Length#22gauge 450feet#20gauge 700feet#18gauge 1100feet#16gauge 1750feet

NOTE:Thelengthofall wiremnsoombinadmustnotexcsad2000feetwhenunshieldedquadconductoroablsisused(1OCOfaatifshieldadtie isused.)If morethan oneconsoleis wired to a run, thentheabovemaximumlengthsmustbedvkfad thenumber

Y!ofconsolesontherun(i.e.themaximumen thwouldbe225feet if two oonsolasarewiredona # 2 gaugeNn),

Up to twelve 4137AD or eight (8) 5137AD or seven (7) 6139 consoles can bepowered from the auxiliafy power output provided that the 750mA rating is notexceeded. The backup battery will supply power to these consoles in the eventthat AC power is lost.Additional consoles can be connected to the system by using a regulated,12VDC power supply (eg. 487-12 supplies 12V, 250mA; 488-12 supplies 12V,500mA). Use a UL Listed, battery backed supply for UL installations. Note that themaximum number of consoles supported by the system is 16.

Connect additional consoles as shown below, using the console wire colorsshown. Make sure to observe the current ratings for the power supply used.Wire run lengths from the 4140XMPT2 to consoles are listed in the WIRINGCONSOLES paragraph (maximum combined wire run lengths for all consolesmust not exceed 2000, or 1000 if shielded cable is used).

IMPORTANT: Make connections directly to the screw terminals as shown. Makeno connection to the wnsole blue wire.The 487-12/488-12 power supplies have a backup battery which can powerthese consoles in the event of AC power loss. Note that consoles powered fromsupplies which do not have a backup battery will not function when AC poweris lost. In this case, make sure to power at least one console from the Control’sauxiliary power output.

-31-

Page 32: ADEMCO manual 4140

EXTERNAL SOUNDERS

Relay Output

UL HouseholdInstallations

Non-UL Installations

Compatible Sounders702

Outdoor Siren (not ULListed)

719Compact Outdoor

Siren (not UL Listed)740

High intensity Sounder

747indoor Siren

ABB1031Motor Beii & Box

PA400B(beige)/PA400R (red)indoor Piezo Sounder

The Control provides a wet beli relay output which is used to power externai aiarmsounders. Connections are made to terminais 4 (positive output) and 5 (negativereturn). See SUMMARY OF CONNECTIONS Diagram. -

For installations which must provide (JL Listed protection, the total wrrent drawnfrom this output and the auxiliary power output, combined, must not exceed750mA in order to wmply with the battery independence requirements. if twoSystem Sensor PA400 piezo alarm sounders, wired in parallel, are used (24mAtotal),then (750MA - 24mA=) 726MA isavailable for auxiliary output use.

For non-UL installations, the total current drawn from this output can be up to 2.8amps. A battery must be installed since current in excess of 750mA is suppiied bythe battery. Up to two 702 sirens can be used, wired in series. Up to two 719sirens can be used wired in parailel.iMPORTANT: Going beyond the above mentioned limits will overload thepower supply or may possibly trip the beli output cirwit protector.

● Self-contained siren (driver built-in) and weatherprmf for outdoor use. Can bewired for either a steady or yeip sound and is rated at 120 dB @ 10 feet. Thissiren can also be tamper protected, or can be mounted in a metal cabinet (716),which can be tamper protected.

● Compact, self-contained siren (driver buiit-in), and weatherproof for outdooruse. Can be wired for either a steady or yelp sound, and is rated at 90 dB @ 10feet. A 708BE cabinet is available, which can be tamper protected if necessary.

● Compact high intensity sounder rated at 123 dB @ 10 feet. This sounder emitsan ‘ear piercing”, high frequency sound. Th”~ sounder can be mounted indoors(bracket included) or outdoors (in 708BE cabinet).

● Attractive, self-contained indoor siren (driver built-in), provides steady or warbletones and is rated at 95dB @ 10 feet.

● AMSECO motor bell& box, rated at 81 dB @ 10 feet. k

● System Sensor indoor piezo sounder (red or beige), rated at 90 dB @ 10 feet.

UL NOTE: Use only UL Listed sounding devices for UL installations.

PHONE CONNECTIONSPhone Line incoming phone tine and handset wiring is connected to the main terminai biock

Connections as follows (refer to SUMMARY OF CONNECTIONS Diagram):TB1-26: Local Handset (TIP)TB1-27: Local Handset (RING)TB1-28: Incoming Phone Line (TIP)TB1-29: IncomingPhoneLine(RING)

If it is desired to connect the panel to phone lines that require ground statlcapability, then a 675 Ground Start Module must be used. This moduie istrggered by one of the outputs on the connector Iabeied J7 (see VOLTAGETRIGGERS section).

Warning To prevent the risk of shock, disconnect phone lines at teica jack before servicingthe panel.

PABX If the communicator is oonnected to a telephone line inside a PABX, be sure thePABX has a back-up power supply that can support the PABX for 24 hours. ManyPABXS are not power backed up and connection to such a PABX wili result in acommunication failure if power is lost.

-32-

Page 33: ADEMCO manual 4140

General The 4140XMPT2 is supplied with a 12.5”W x 14.5”H x 3“D cabinet suitable foruse in residential and non-cedified commercial burglary installations.Mount the Control cabinet to a sturdy wall using fasteners or anchors (notsupplied) in a clean, dry area which is not readily accessible to the general public.The back of the Control cabinet has 4 holes for this purpose.Follow the instructions below for mounting the 4140XMPT2 PC board into thecabinet and for mounting the Control’s lock to its cabinet door.

Mounting The Before mounting the circuit board, be certain that the appropriate metal4140XMPT2 PC Board knockouts have been removed. DO NOT ATTEMPT TO REMOVE THE

KNOCKOUTS A~ER THE CIRCUIT BOARD HAS BEEN INSTALLED.

1,

2.

3.

Hang the three mounting clips on the raised cabinet tabs. Observe properclip orientation to avoid damage to the clip when mounting screws aretightened and to avoid problems with insertion and removal of the PC board.

Insert the top of the circuit board into the slots at the top of the cabinet, Makecefiain that the board rests in the slots as indicated in step 2 detail.

Swina the base of the board into the mountina clim and secure the board tothe ~binet with the accompanying screws (as~llu~rated in step 3 detail).

Advisory Make certain that the mounting screws are reasonably tight to insure that there isa good ground connection between the PC board and the cabinet. Also, dressfield wiring away from the microprocessor (center) section of the PC board. Thecabinet provides 2 loops on its left and right sidewalls for anchoring field wiringusing tie wraps. These steps are important to minimizing the risk of panel RFinte~erence with television reception.-

Slw a—

@

8A

f--=%Y// “’cY’

DETAIL SIDE MEW OFCLIP lNSTALLAnC+(b. CAOINEl TAB

WITHOUT CLIP0.CAWNW TAB

wm MN01N13 cL*

DETAIL SIDE VIEWOF CLIP ANLI BOARDINSTALLED

Mounting The Cabinet 1.Lock

2,

Remove the lock knockout onthe control cabinet cover, Insertthe key into the lock. Position thelock in the hole making certainthat the latch will make contactwith the latch bracket when thedoor is closed.While holding the lock steady,insert the retainer clip into theretainer slots.

LOCKED

I a(,0RETAINER CUP

*

‘@

... :. .

-..

““””\UNLOCKED

c.AwNEl OcoFl Ea-mM

.m#mcw_

TREIuNERS1.ols

-33-

Page 34: ADEMCO manual 4140

Primary Power

Back-Up Power

Earth GroundConnections

Power-Up Procedure

Power to the Control panel is supplied by model No. 1361● Plug-in Transformerwhich is rated at 16.5VAC, 40VA. Caution must be taken when wiring thistransformer to the panel to guard against blowing the fuse inside the transformer(non-replaceable).

‘ NOTE: Use 1361CN Transformer in Canadian installations.

In the event of an AC power loss, the Control panel is supported by a back-up,rechargeable gel cell battery. YUASA NP4-12 (12V, 4AH) and NP7-12 (12V,7AH) batteries are recommended. Do not use Gates batteries (sealedlead-acid type).

The standby battery is automatically tested every 24 hours, beginning 24 hoursafter exiting programming mode. In addition, entry into the test mode will cause abattery test to be initiated.

BATTERY STANDBY TABLE NOTE: These figures are

~ !g~%~~~

AMP-HRS. “200mA 400mA 600mA 750mA

In order for the lightning transient protective devices in this product to beeffective, the designated earlh ground terminal, must be terminated in a goodearth ground. The following are examples of good eaflh grounds available at mostinstallations: w

Metal Cold Water Pipe: Use a non-corrosive metal strap (copper isrecommended) firmly secured to the pipe to which the ground lead is electricallyconnected and secured.AC Power Outlet Ground: Available from 3-prong, 120VAC, power outletsonly. To test the integrity of the ground terminal, use a three-wire circuit testerwith neon lamp indicators, such as the UL-Listed Ideal Model 61-035, orequivalent, available at most electrical supply stores.

1.

2.

3.4.

5.

Fill out the Polling Loop Current Draw and Auxiliary Device Current DrawWorksheets shown below. Make sure that the currents drawn from theseoutputs do not exceed their respective ratings.CAUTION: Failure to observe the polling loop current rating will causepolling loop malfunction. Failure to observe the auxiliary output current ratingwill result in a battery which does not charge properly or possibly a trippedcircuit breaker.

Wire the 1361 transformer (1361 CN in Canada) to the panel (beforeconnecting the battery) as shown in the SUMMARY OF CONNECTIONSdiagram. Do not plug in at this time.Connect all polling loop and auxiliary devices, such as consoles, PIRs, etc.Plug the 1361 into an 24 hour, uninterrupted AC outlet. After a few seconds,the green POWER LED on the console(s) should light and the console(s)should display “DISARMED READY TO ARM.”Connect the battery as shown in the SUMMARY OF CONNECTIONSdiagram.

-34-

Page 35: ADEMCO manual 4140

POLLING LOOP CURRENT DRAW WORKSHEETRPM DEVICE CURRENT # UNITS TOTAL

CURRENT4194 Contact lmA4192SD Photo Smoke 0.4 mA4192SDT Smoke w/Heat 0.4 mA4192CP Ion Smoke 0.4 MA4275 Dual PIR lMA4278 Quad PIR lrnA4190 2-Zone RPM 1 MA (LOW)

2 MA (HIGH)4208 8-Zone RPM 16mA428063 Zone RF 40 mA4280-88 Zone RF 40 mA

TOTAL **● * If the total current draw exceeds 64 MA, a 4197 Loop Extender module must be used.● * If using two 4280s or 4280-8s, you can power one of them from auxitiary power instead of using a 4197 bop

extender module.

AUXILIARY DEVICE CURRENT DRAW WORKSHEETID EVICE i CURRENT I # UNITS I TOTAL I

CURRENT4137AD Console 60mA5137AD Console 90 mA6139 Console 100mA675 Ground Start Module 50 mA4280 or 4280-8 Receiver 40 mABuilt-in Pollinq LooP (totalp II1001)worksht)4281 RF Receiver 35mA5881 RF Receiver 50mA4197 Poll Loop Extender 80 mA●

TOTAL (750mA max)● If using hard-wire devices such as PIRs, refer to the specifications for that particular unit’s current draw.

Only applies if powered from Control’s auxiliary power.—

-35-

Page 36: ADEMCO manual 4140

PROCEDURE

m1

NOTE: A 5137AD or 6139 alpha console must be used to set the real-time clock,or the clock can be set via the Downbader software. Only users with installer ormaster authority level can set the real-time clock,

w

To enter real-time clock mode, enter installer or master code + #63. Atypical display will show:

I TIM13DATE - THU ~~12:01 AM 01/01/90 I

The day of the week is automatically calculated based on the date entered. Timeand date entries are made by simply entering the appropriate hour, minute,month, day and year. Pressing the ~] key accepts the entered value and movesthe cursor to the right. Pressing the [#] key moves the cursor to the left of thedisplay, to the prevbus position.To set the time and date, simply enter the correct hour then press ~] tomove to the minutes and make the correct entry.Press ~1again, then toggle the AM/PM by pressing any key O-9.Press ~] to move cursor to the month position and enter the correct month usinga 2digit entry.Press ~] and enter the correct date.Press [*] and enter the correct year.To exit clock mode, press the ~] key after the cursor is in the year position.

-36-

Page 37: ADEMCO manual 4140

. @ ● O“*AO

SECURITY ACCESS CODES

General Information

User Codes & Levels OfAuthority

Level Titleo Instailer1 Master

The System aiiows up to 128 security acoess codes to be assigned (maximum 99per partition), each identified by a user iD number. in addition, the Quick Armfeature can aiso be programmed, wh@ enabies the [#] key to be pressed insteadof entering the security code when arming the system. The code must stili beentered when disarming the system.Note that Open/Cbse reporting of Quiok Arm is enabied if User 2 is enabied forOpen/Ciose reporiing, and that Quick Arm reports as User O.

Each user of the system can be assigned various Ieveis of authority (tells systemwhat system functions that user is authorized to do), and can have different ieveisof authority within each parlition. Use the “View Capabilities” keypad funotion toview the partitions and authority Ieveis for which a particular user ~Sauthorized. Inhighest to lowest ranking, these ieveis are described below.

nstaller “ Programmedin field●OO(defautt=4-14-O).Level O) Can be changedby installer.Jser 1 ● Can perform aii system functions (arm, disarm, bypass,

etc.) and is the oniy user that can enter program mode.● Oniy code that aiiows entry to program mode.s instailer code iockout if exit program mode via ’98. This

prevents instaiier from reaccessing program mode. Theonly way to access Programming mode once this featureis activated, is by powering down the system andpowering up again, and then pressing both the ● and #keys at the same time within 30 seconds of power up.

● The instaiier must program at ieast one mastercode. Master codes are the codes intended for use bythe primary users of the system.

● Can add, deiete, or change master, manager, or operatorcodes.

● Can select open/close reports for any user.● Can perform normai system functions, but cannot

disarm if armed by a code other than Instalier’s code(inoluding Quick Arm).

● Enable open/ciose reporting for instailer in field ●39.

Master (Levei 1) ● The Master Code is the code intended for use by theprimary users of the system when performing systemfunctions, and oan be changed by the Master User.

● The master codes can be used to assign up to 99 lowerlevel codes, which can be used by other users of thesystem who don’t have a need to know the master code.

● As shipped from the factory, there are no master ormanager codes pre-programmed. The installer mustprogram at ieast one master code during initiaiinstailation.

● Master cannot assgn anybody a ievel of Oor 1.● Can change his own code.● Can add, delete, change manager or operator codes.

Each user’s code can be individually eliminated orchanged at any time.

s Open/close reporting of added users are same as thatof the master or manager adding the new user.

● Can perform ali system functions.

-37-

Page 38: ADEMCO manual 4140

Ueer Codes & Levels OfAuthority (cont.)

danager (Level 2} w Can perform all system functions (Arm, Disarm, Bypass,etc.) programmed by Master.

c May create other users of the system below this level(Manager cannot assign anybody a level of 0,1, or 2).

● May change his own code.● May add, delete, change operators.‘ Open/close reporting of added users will be same as his

own (enabled or disabled as assigned by installer ormaster).

● May operate a pattition.lperator ● Operators can arm and disarm the system to the authorityLevels 3-5) assigned, but cannot add or modify any user code.

“ May operate a partition with one of the threeOPERATOR authority levels A through C listed below.Level Title Functions Permitted

Operator A Ann, Disarm, Bypass: Operator B Arm, Disarm5 Operator C Arm, Disarmonly if armedwith

same code● Operator C (sometimes known as Baby-sitter code),

cannot disarm the system unless the system was armedwith that code. This code is usually assigned to personswho may have the need to arm and disarm the system atspecific times only (ex. a baby-sitter needs to control thesystem only when baby-sitting).

)uress (Level 6) ● The duress code is a means of sending a silent alarm to acentral monitoring station if the user is being forced todisarm (or arm) the system under threat. This feature isonly useful if the system is connected to a central station.

● When the system’s Auxiliary Voltage Triggers areconnected to another communication’s media (DerivedChannel/Long Range Radio), note that duress issignaled on the same trigger that signals silent panic(whereas duress has its own unique report when digitallycommunicated).

● The duress code is assigned on a pattition by pafiitionbasis and can be any code desired.

● When used, the system will disarm (or arm), but will alsosend a silent alarm to the central station (if service isconnected). There will be no indication at the consolethat an alarm was sent..

● Duress Reporting Note: The Duress report triggeringlogic activates on the 5th key depression (such as OFF),not the 4th key depression (last digit of code). Duressreports will not be triggered if the 5th key is a ~], such aswhen performing a GOTO or viewing the capabilities of auser.

Dpen/Close Reporting Note: When adding a user, the system will onlyprompt for Open/Close reporl capability if the user is being added by the Installer.When a Master or Manager adds a new user, the new user’s Open/Closereporting enable will be the same as that of the Master or Manager adding theuser. If Open/Close reports are required to be selectable by the Master orManager, the Installer should assign two Master or Manager user codes: one withOpen/Close reporting enabled, and one without Open/Close reporting.

-38-

Page 39: ADEMCO manual 4140

General Rules on Authority Levels and changes

Multlple PartitionAccess Examples(GOTO Function)

The folfowing rules apply to users when making modfiications within the systembased on the user oode authority levels:● Master Codes and all lower level codes can be used interchangeably when

performing system functions within a partition (a system armed with a user%temporary code can be disarmed with the Master Code or another usetstemporary code), except the Operator Level C Code described above.

● A user may not delete or change the user code of the SAME or HIGHERauthority than wh~h he is assigned.

c A user (levels O,1 & 2 onfy) may only ADD users to a LOWER authority level.● A user may assign other users access to only those partitions to which he

himself has access.● A user can only be DELETED or CHANGED from within the partition he is

assigned.● User numbers must be entered as 2digit entries. Single digit user numbers

must, therefore, always be preceded by a “O” (example, 03, 04, 05, etc.). Makesure the end user understands this requirement. Temporary codes are enteredas 4-digit numbers.

Important !: Unless Ademco Contact ID reporting is used, only user codes #1 -#15 can uniquely report to the central station using the communication formatsprovided. Users #16 - #99 will report as User #15, if enabled for open/closereporting, for the other reporting formats.

To make a partitioned environment particularly useful, the system must allow forcertain people to have access to other partitions. This is particularly true in theFactory/Office environment where the president of the company wants access toany area of his company. The 4140XMPT2 has total flexibility in supporting thisrequirement. On a USER basis, each user is programmed for a base partition (theone he normally is assigned) and one or more partitions which he can beauthorized to access.In addition, within each partition, each USER may be programmed to havedifferent levels of authority. For example, User #3, the V.P. of Engineering,could be assigned to work within the Engineering Department (Partition 1) ofABC Manufacturing. Since he needs the full capabilities in his area, he isassgned as a MASTER with Level 1 authority. This means he may Arm, Disarm,Bypass, Add or Modify users in partition 1. It is also a requirement that he be ableto gain access to the manufacturing area (partition 2) on an emergency basis. Youcan set this up easily with the 4140XMPT2 by now requesting that he also beassigned to partition 2, with a level of authority set lower, such as Level 4(OPERATOR Level B) which allows him to Arm and Disarm, but nothing else. Thecontrol will automatically assign him the next available user number within partition2 and does not require reprogramming of his already existing 4 digit securitycode! This type of setup can be done for each user of the system and for anycombination of up to 8 partitions!EXAMPLE OF MULTIPLE PARTfTION ACCESSPart1 Pari2 Part3 Part4 [ Part5 Parl6 Part7 Patt8user3 user5LC!WI 1 LSWSI 4 IMasterIWEI I 4

In the above example, User 3 has MASTER authority in partition 1 andOPERATOR B authorii in partition 2. His user number in partition 2 is User 5 andhis 4 digit code is the same for both partitions. Note that if a user number isalready being used in a partition, the system will automatically assign an unusedUser number.Assigning users to other partitions is one thing, but how about actually being a userand trying to “see” one of the other partitions? The 4140XMPT2 has developed asimple key sequence (code + ~] + partition number O-8, partition Oreturns to thedefault partition for that console) scheme for a user to go to another partition.

-39-

Page 40: ADEMCO manual 4140

To ADD a Maater,Manager or Operator

code

Installer must program atleast one Mastsr cods.

- Or Master or Manager code,but must be code with higherlevel of authority than the codebeing changed. (i.e. Mastercode can add a Manager orOperator level code, butcannot add another Mastercode; a Manager code can addan Operator level code, butcannot add a Master or anotherManager code).

Once there, the current display becomes attached to that partition and statusrequests, etc. are now displayed for that partition, unless a period of 120 secondselapses with no key entries. To return to your original partition, you may enter thesame key sequence and end if with your normal partition number or “O”. You’renow back to where you started. It’s that simple! You may view this operation as a ~big selector switch and you are at the switch at the console.EXAMPLE: User may be regularly assigned to partition 1. This would be thedefault display for this user, however he may “select” to go to partition 2 forexample. (Assumes he has been programmed for access to partition 2) The userenters his normal access code and the proper sequence to select anotherpartition followed by the number 2 for partition 2. The display will now selectpartition 2 information for view and further action. In the above example noticethat no access is allowed for this user into partitions 3-8. Attempts to accessthese partitions would be denied automatically.

Important!: Duringuser code entry, normal key depressions at other consolesin a partition will be ignored. However, panic key depression will cause an alarmand terminate user entry.

Enter Installer Code- + [8]+ new User # (00-99) + new Usets codeConsole will prompt for the Authority Level for this user.

EEKl

EmclAccess Group?Enter O-8

Enter the level number as follows:1= Master (Arm, Disarm, Bypass, add or modify lower

level users)2 = Manager (Arm, Disarm, Bypass, add or modify lower

level users)3= Operator Level A (Arm, Disarm, Bypass)4= Operator Level B ( Arm, Disarm)5 = Operator Level C ( Arm, Disarm only if system armed

with this code)6 = Duress (Arm, Disarm, triggers silent panic alarm)Console will then prompt for Open/Close reporting optionfor this user. -

Press O (NO) or 1 (YES), depending on whether ornot arming/disarming by this user will trigger opening& closing reports.If access schedules have been programmed, thisprompt appears. Enter the user’s access groupnumber (1-8) if this user should have limited accessto the system. Enter O if no access group should beassigned.If a 5800 series button transmitter has been enabled,and not assgned to a user, this prompt will appear.

If yes was given as the answer to the RF buttonquestion, the zone number for the button will berequested. Enter one of the zone numbersassigned to the button transmitter as AWAY, STAYor DISARM. The system will then assign any STAY,AWAY or DISARM buttons of the transmitter to thisuser number..

Press O(NO) or 1 (YES). If NO, the program exits thismode. If yes, the Console prompts for the Global Armoption for this user.Press O (NO) or 1 (YES), depending on whether ornot this user will be allowed to arm more than onepartition via Global Arm prompts (described in theKEYPAD FUNCTIONS section) .If the Multi-Access option was selected for this user, w

the console now prompts for the user’s access tothe next partition.

-40-

Page 41: ADEMCO manual 4140

[ Part. 2- SHOP ? [ Press O (NO) or 1 (YES), depending on whether or

To CHAHGE a Master,Manager or Operator

code

To Delete a Master,Manager or Operator

code

To EXIT The User CodeEntry Mode

.—. ..— -.. —..10= NO, I= YES I

not this “user will ‘have atiess to- the dispiayedpartition number. If NO, the console displays thisprompt for the nexl partition number in sequence.If YES, the console prompts for the following:● User’s authority level in the displayed partition (see

Authority Level prompt above). Note that the usernumber in the displayed partition is automaticallyassigned.

● Open/Close option for this user in the displayedpartition (see Open/Close prompt above).

● Global Arm option for this user in the displayedpartition.

When all partitions have been displayed, the consolewill scroll through all partitions to which access hasbeen assigned, and will display the user number,authority level, open/close and global arm optionsthat were programmed for each partition the user wasgranted access. For example:

~

Note that the ‘G” following the authority levelind”cates that the global arm feature is enabled forthis user in the displayed partition, and that theperiod at the end of the second line indicatesopen/close reporting is enabled for this user in thedisplayed partition. The “S” idicates the parlition fromwhich the user may be changed or deleted.

Enter Installer code* + [8]+ User number (00-99) + new code for that user.The system will detect that the user number is already assigned and will prompt ifthis is a new user. Press O(NO).

The system will then confirm that the change is allowed based on authorizationlevel. If the user number is the same as the Installer’s, the system will prompt forthe new code to be reentered. This prevents accidentally changing a high levelcode.

● Or Master or Manager code, but must be code with higher level of authority thanthe code being changed. (i.e. Master code can change a Manager or Operatorlevel code, but cannot change another Master code; a Manager code can changean Operator level code, but cannot change a Master or another Manager code).

Enter Installer code* + [8]+ User number (00-99) + Installer code

The system will prompt if this code should be deleted. Press O(NO) or 1 (YES).If yes, that user’s code will be removed from all partitions to which it had been

assigned, and all authorization levels and other information about that user will bedeleted. Note that a user can only be deleted from the partition in which it was firstassigned, and can only be deleted by a user with a higher authority level. A usercannot delete himself.● Or Master or Manager code, but must be code with higher level of authority thanthe code being deleted. (i.e. Master code can delete a Manager or Operator levelcode, but cannot delete another Master code; a Manager code can delete anOperator level code, but cannot delete a Master or another Manager code).

Press either [Q] or [#], or don’t press any key for 10 seconds.

-41-

Page 42: ADEMCO manual 4140

KMYPAD FUNCTIONSOOn*ral Information

Not@that USW relatadochodulln@ functloneand programmln la

ido~crlbod In t oProgramming guldo(sottlng temporary

ochoduloo,programming tlmod

went., ate.)

Arming Punetlons

Note that if QUICKARMisensbled(field*29), the M] key

Cenbe pressedinsteadofenteringthe securitycode,foranyof thearmingprocedures

(Away, Stsy, InstsntjMaximum,etc.).

The koypacf allows the user te arm and disarm the system, and perform othorsystem functions, such as bypasulrt zoneq view mes6a e6 from the centralstation and display zone descriptors, ! !one andsystem oortcf ions (alarm, trouble, ~bypass) are displayed in the Display Window,When an alarm oooura, ooneole sounding and external sounding will ocour, andthe zone(e) In alarmwill be dl$played on the ooneole, Pressing arty key will silencethe console sounder for 10 $eooncls. Disarming the sy$tem will sllertoe bothocmole and external sounders. When the system is d16armed, any zones thatwere in an alarm oondition during the armed period will be displayed(memory ofalarm), To clear this display, simply repeat the disarm sequence (entsr the seourttyoode andpress the OFF key).The oa’t801e8 also feature chime annunciation, and 3 panio key pairs (for ellent,audible, fire or personal emergency alarms) which can notify the central station ofan alarm oonditlon, If that sWoe is ccmneoted.The following is a brief [let of system commands. For detailed informationOonoerningsystem funotions, refer to the User’s Manual.Disarmed Not Ready Before arming, the 6ystem must be In the READY

oonditlon (all zones must be Intaot).If the “NOT READYmessage appears, press the READY [“] key to efispiayfauited zones.

Arming Away Entercode + AWAY [2].Arming Stay Entercode + STAY [3],Arming Instant Enter code + iNSTANT [7J.Arming Maxlrnum Enter code + MAXIMUM [4].Global Arming if enabied for the user, the consoie wiii display the

foilowing:

ARM ALL ? 1

I O= NO,l=YES Iif NO, the consoie prompts for arming each partitionindivlduaiiy, If YES, the system attempts to arm ali \partitions aiiowed by this user. If there are any fauits(open doors, windows, etc.) the consoie wiii dispiaythem. See notes beiow. These fauits must be correctedor the zone bypassed before arming wiil occur. Whenfauits are corrected, repeat the arming procedure.Global Arming Notes:1, When using the Giobal Arm feature, if there are faults in

any of the selected partitions, the system will enter asummary mode in which the faulted zones of all of theselected partitions will be displayed. These faults must becorrected or bypassed (code+ BYPASS+ [#] will attemptto bypass the faults in all of the selected partitions). Thissummary mode will end in approx. 120 seconds if no keysare pressed.

2. If, when disarming the system using a Global Disarm, anyof the selected partitions has a condition which wouldcause the console to beep (such as alarm memory or atrouble condition), the system will cause the console tobeep and will enter a summary mode in which the alarmmemory or trouble conditions of all of the selectedpartitions will be displayed. This mode will continue untileither approx. 120 seconds elapses or a second disarmoccurs which clears the beeping condition.

3. Global arming cannot be performed from a wireless keypador a non-alpha display console.

Disarming Entercode + OFF [1].Bypassing Zones Enter code + BYPASS [6] + zone number. To

automatically bypass aii fauited zones, use “QuickBypass” method: Enter code + BYPASS+ [#]. -

Chime Mode Enter code + CHiME [9]. To turn chime mode off, entercode + CHiME again.

-42-

Page 43: ADEMCO manual 4140

Mode Features For Each Arming ModeExit Entry Perimeter InteriorDelay Delay Armed Armed

AWAY Yes Yes Yes YesSTAY Yes Yes Yes NoINSTANT Yes No Yes NoMAXIMUM Yes No Yes Yes

Access Control If programmed, one relay maybe used for access oontrol. To activate this relay,the user enters his user code + [0]. The relay will pulse for 2 seconds.

Delay Closlng Time If open/close schedules are used, end users can manually extend the closingwindow by up to 2 hours. This is useful if a user must stay on the premises laterthan usual. User must have authority level of manager or higher.To extend the closing window, enter user code + # +82, The following will bedisDlawd.

EE!EIEnter the number hours, 1 or 2, by which the end of theclosing window should be delayed. Note that the delay isfrom the scheduled closing time, not from the current time.Press ● to acoept entry and exit this mode. Press # to exit thismode without changes.

The system will send a “Schedule Changed” message to thecentral station when the closing window is delayed.Important: The delay cannot be reduced onoe it is set. It canonly be increased. This is to prevent the user from deletingthe delay after the normal window expires, thereby missingthe end of the window.

Partition “GotoM Each console is assigned a default partition for display purposes, and will showCommands only that partition’s information. To see information for another partition, or

perform system functions in another partition, use the GOTO command (code+~] +pattition number O-8). The oonsole will remain in the new partition untildirected to go to another partition, or until 120 seconds has elapsed with nokeypad activity.

View Capabllltles Of A The console will display the partitions that user is authorized for, the userUser number, and the authority level for all partitions authorized. Enter oode + [X] +

[x]. The user’s capabilities in each authorized partition will typically be disp~y~as follows:

mThe user’s Open/Close report capability is shown by the dot following theauthority level. If Open/Close is not enabled for a user, the dot will not appear.

Viewing Downloaded Users may occasionally receive messages on the console display from theirMessages installation oompany. When this occurs, the console will display “Message. Press

Ofor 5 sees.”. Instruot the user to press and hold the Okey to display the centralstation’s message. Note that the system must be in the READY state to viewthese messages.

Using The Built-in An abbreviated User’s Manual is stored in the system’s memory, and can beUserls Manual particularly useful to the end user if the printed Usets Manual is not mnveniently

accessible when the user needs to perform a seldom used and unfamiliar systemprocedure. The Built-in Usets Guide is displayed by simply pressing any of thefunction keys (e.g., OFF, AWAY, STAY, MAXIMUM, BYPASS, INSTANT, CODE,TEST, READY, #, and CHIME) for approximately 5 seconds and then releasing it.Abbreviated instructions relative to the key that has been pressed will then bedisplayed (2 lines of text are displayed at a time). This function operates in eitherthe armed or the disarmed state.

-43-

Page 44: ADEMCO manual 4140

Dlsplaylng Descriptors

Panic Keys

Trouble Conditions

‘CheckU Messages

Other TroubleConditions

Power Failure

The Alpha Consoles can display all programmed descriptors, which is useful tothe installer when checking entries, and can be helpful to the user when there is aneed to identify zones. TO display descriptors, press and hold the READY keyuntil the built-in instructions for that key appear, then release the key. The zonedescriptors will appear one at a time, for about 2-3 seconds each. For faster ~viewing, press the READY key to display the next descriptor in numerical orderand so on. When all descriptors have been displayed, the Control will exit displaymode. To exit display mode before all descriptors have been displayed, enter thesecurity code and press the OFF key.

There are three panic key pairs (shown below) that, If programmed, can be usedto manually initiate alarms and send a report to the central station. Each key paircan be individually programmed for 24 Hour Silent, Audible or Auxiliary(Emergency) responses. The panic function is activated when the appropriatekey pair is pressed at the same time.The panic functions are identified by the system as follows:

PANIC n~~] +[1] 95 For 5137AD consoles, these panic keys can also be~]:;] :: programmed with an alpha descriptor.

IMPORTANT: For the Panic functions to be of practical value, the system mustbe connected to a central station.

The word “CHECK” on the Console’s display, accompanied by a rapid ‘beeping”at the Console, indicates that there is a trouble condition in the system. Theaudible warning sound can be silenced by pressing any key. Instruct users to callfor service immediately upon seeing any of the following messages.

● A display of “CHECK” accompanied by a display of one or more zonedescriptor(s) indicates that a problem exists with those zone(s). First, determineif the zone(s) displayed are intact and make them so if they are not. If theproblem has been corrected, key an OFF sequence (Code plus OFF) to clearthe display.

● A display of the word “CHECK” accompanied by a numeric display of “97” ~indicates that a short exists on the Polling Loop and may eliminate some of theprotection. Fault “97” can be assigned an alpha descriptor when using the5137AD console.

● A display of the word “CHECK accompanied by a numeric display of “88, “89”,“90”, or “91” indicates a 4280 Receiver problem. Faults “88”, “89” “90” & “91”can be assigned alpha descriptors when using the 5137AD console.

● A display of “COMM. FAILURE” (5137AD) or “FC (4137AD) at the Consoleindicates that a failure occurred in the telephone communication portion of yoursystem.

● A display of “LO BAT” (5137AD) or “BAT” (4137AD) and a zone descriptor,accompanied by a once per minute beep at the Console indicates that a lowbattery condition exists in the wireless transmitter displayed. The audiblewarning sound may be silenced by pressing any key. A display of ‘SYSTEM LOBAT” (5137AD) or “BAT” with no zone number (4137AD) indicates that a lowbattery condition exists with the system’s backup battery.

● A display of “RCVR SET UP ERROR” (5137AD) or “E8” (4137AD) at theconsole indicates that the system has more RF zones programmed than the RFreceiver can support, If this is not corrected, none of the zones in the systemwill be protected. If more than 8 RF zones are desired, use a Receiver thatsupports more than 8 zones (4280, 4281 H, 5881 H).

● A display of “MODEM COMM” (5137AD) or “CC” (4137AD) indicates that thecontrol is on-line with the remote computer and the control is not operating.Panel’s response to alarm and trouble conditions will be delayed until on-linesession is completed.

If the POWER indicator is off, and the message “AC LOSS” (5137AD) or “NO AC”(4137AD) is displayed, the Console is operating on battery power only. Check tosee that your system’s plug-in transformer has not been accidentally pulled out. ~Instruct the user to call a service representative immediately if AC power cannotbe restored.

-44-

Page 45: ADEMCO manual 4140

EVENT LOGGINGEvent Logging Printer Connector J8, located above connector J7 on the right side of the main PC

Connections board, is intended to be interfaced to a local serial printer via the 41OOSMserialinterface module, in applications where it is desired to print the event log on alocal printer.

Mount the 41OOSMusing its clip bracket to attach it to the side wall of the controlcabinet. Make connections between J8, the 41OOSM module and the serialprinter as shown below. Refer to the event logging commands paragraph for adescription of the console commands which initiate event log printing.

NOTE 1: Printer must be configured as follows:● 8 data bns, no parity, 1 stop bit● 300 or 1200 baud (1200 preferred)● Hardware handshaking using DTR signal

NOTE 2: The 41OOSMmodule is supplied with a 10 foot RS232 cable. A longercable or an extension cable can be used if the 4140XMPT2 and serial printer areseparated by more than 10 feet, but the total cable length should be less than 50feet.

NOTE 3: Most printers either ignore the CTS, DSR and CD signals, or requirethem to be high (i.e. 3-15VDC as measured on RS232 DB25 connector pins 5, 6& 8 respectively with respect to ground pin 7). The 4100SM module sets thesepins high. If the printer being used will not operate with these pins high, then clipthe blue (CTS), white (DSR) or red (CD) jumpers on the 4100SM module to setthe corresponding signal floating. Impotlant pins on the RS232C cable are pin 3(data out), pin 7 (ground) and pin 20 (DTR - ready).

NOTE 4: The DTR signal, as measured at 41OOSMTB1, should be high (9.5-14VDC) when the printer is powered, properly connected, on-line and ready toprint. This signal will be low (O-1.5VDC) when the printer is not powered, notproperly connected, off-line or out of paper. The 4140XMPT2 will not sendprinting data to the printer unless the DTR signal is high.UL NOTE: A UL Listed EDP printer must be used for UL installations.

s CoNNEcmn

— —

4142TR -E fswmlEO WI+ 41fts14

4tmm SEBIU MciOu1. 7s6 An Ran, (*](Z%71AOmaM &mv) -@ .FwR

To TB7 h. Pm {-) — -@ - mm)

6 mm

@ Ildund

@ uw.d

@ nul130d

@ Ildwed

I DTR

l!mshl wEW(CUT 10 SET FIESPECWW S’,3MN FwATIW,

ddd*D OWEWV

m I IUSE GEWRCWER suwum

U

Ion.

WTH 4,w5M F CDW

FUIMTEl! HAS DE.% ~wmMALECO.WECTOR

I {

c1SElnu PFWTERmm D@ATAm’s

!83 PmIstwmlZrKvmw

—~(sM30m5muL -45-

Page 46: ADEMCO manual 4140

Event LoggingProcedures

IMPORTANT: In order for time and date stamdna to occur. thelsystem’s real-time clock must be set. Refer to” th~ SETTING” THEREAL TIME CLOCK section.

The system has the abilityto recordvariousevents in a historylog (224 eventcapacity)whereineach event is recorded in one of five categories (alarm, check, ebypass, open & system), with the time and date of its occurrence (if real-time clockis set). The log maybe viewed (Display Mode) using an alpha console, or can beprinted (Print Mode) on a serial printer (connected to the system via a 41OOSMSerial Module).EVENT LOG MODE COMMANDSDisplay Mode (installer or master): EnterCODE + [#]+ [6]+ [0]Print Mode (Installer only): EnterCODE + [#]+ [6]+ [1]Clear Event Log (Installer only): EnterCODE + [#]+ [6]+ [2]To EXIT Event Log Mode: Press [Q] at anytime.

Programming The systemcan be configuredfor the following event log activities:9

To either record events but not print them unless commanded to do so, or toautomatically print the events as they occur (field 1●72),Specific categories of events to be logged can be selectively enabled (field1“70).

The time stamp can be programmed for either 12 or 24 hour formats (field1’71).The printer baud rate can be set to either 300 or 1200 baud (field 1●73).Set event log time/date report enable (fields 1*4O& 1’41).Enable reporting of event log capacity (i.e.. 50% full, 90% full & overflow)programmed in fields 1●4O & 1●41.

Event Logging Display After entering event log mode, the following will be displayed:& Print Modes

~

The Event Log holds up to 224 events, and can display or wprint all events in a category (complete), or only thoseevents in a category occurring since the last Clear EventLog command (recent). Note that once the Event Log isfull, the oldest event will be erased upon the logging of anynew event. Press the desired display mode key, Oor 1.

=

SCAN LOG BY PART The system allows viewin9 of any Pafiition’s event ~9.Enter the partition number for the partition whose eventsare to be displayed. Entering O(NO) will display all eventsthat occurred in the system regardless of parlition.For display and printing purposes, events are stored on apartition by partition basis (except system events), andare grouped into five categories as follows.

Use the [3] & [1] keys to scroll to the next or previous category screensrespectively:

ALARM EVENT LOG Displays timefdate for zones that have either caused anTYPE CCC UUU alarm or have been restored in selected partition.

CHECK EVENT LOG Displays timefdate for zones that have caused a trouble orlWPE CCC UUUBYPASS EVENT LOGTYPE ccc UuuOP/CL EVENT LOGTYPE CCC UUUSYSTEM EVENTLOGTYPE CCC UUU

ALL EVENT LOGTYPE CCC UUU

supe~isory condition in selected partition.

Displays time/date for zones that have been bypassed inselected partition.Displays time, date and user number for each arming anddisarming of the system for the partition selected.

Displays time/date for system problems, such as ACLoss, communication failure, etc., regardless of partition.Displays all categories of events in chronological order, ~from most recent to oldest.

-46-

Page 47: ADEMCO manual 4140

To display the events In a particular category, press [8] at the desired

Clear Event Log

Soreen Deflnltions

catego~ tireen.If in Display Mode, events will appear one at a time from the most recent to theoldest. Press [8] again to display each subsequent event.If in Print Mode, the first press of [8] will cause the printer to print all events in thatcategory, with each event automatically scrolled on the display console. Thefollowing is a typioal display:

-12@2AMonJ-lP8 oI/ol 12:02AM ShOWSbuwlaw alarm OCOUrmdin zone 3 Of panh~n 8, ~

After the last event in the seleoted oategory has been displayed, the following willappear for a few seoonds:

IEND OF EVENT LOGTYPE CCC UUU IThe system will automatically return to thesoreen described earlier.

RECENT/COMPLETE selection

To clear the Event Log, enter installer code + [#] + [6] + [2]The following will appear:

I CLEAR EVENT LOG I\ O=NO 1=YES IPress [1] if Event Log is to be cleared from memory. All events in the log will stillbe displayed if the COMPLETE option is selected. Only those events oocurringfrom the time of the CLEAR command will be displayed if RECENT display optionis selected. Press [0] if event log is not to be cleared at this time.If [1] is pressed, the following will appear:

lawLlPress [1] if it is desired to clear the event log. Press [0] if event log is not to becleared.

t nrnrhll- 1 !!------- -:--- I--* /-1 EAR I

Vuw 1 &

111 MI 1

~Fire, etc.) 1w w {WI uabt) I IUI I Ioer

1Uuu I User number I

-47-

Page 48: ADEMCO manual 4140

DIRECT WIRE DOWNLOADING

Dlreot Wire The 4140XMPT2 can be downloaded without using a modem or telephone lineDownloading by using 4130PC Downloading Software and a ~1OOSM Serial Module. TheConnections direct wire downloadingconnection is to be temporary, and is not pad of the w

permanentinstallation.Directwire downloadingis meant as a tool for the installerduring the installation process.

IMPORTANT: Ths connections between the 4140XMPT2 and the41OOSM are different than those shown in the 41OOSM InstallationInstructions. See diagram below for correct connections. In addition, when the“green” wire is referred to in step 2 of the IN CASE OF DIFFICULTY sectionof the4100SM Instructions. use the “violet” wire.

Connector J8, located above mnnector J7 on the right hand side of the main PCboard, is intended to be interfaced to either a local serial printer (see EVENTLOGGING CONNECTIONS) or a computer. Make connections to a computer asshown below. Note that the violet wire connection for a computerdiffers from that used when connecting a serial printer.

9 4142TR CABLE (SUPPLIED WITH 4f oOSM)

41OOSM SERIAL MODULE

To T&j Aux. Powr (+)(25mA current draw)

To 1S7 AUK.Power (-) ~- (GND)

Q IKllused

@ nOllJaeId

@ Txo

LJ@ml used

@ Mused

CfddRED 91uE WHITE

-48-

Page 49: ADEMCO manual 4140

Spilt/Dual Reporting

Ademco Low Speed

Sescoa/Radionics

4+2 Reporting

Dual reporting (’51 ) sends all reports to both primary and secondary phonenumbers. Split reporting allows reports to be divided between the phone numbersaccording to the fields (1’34) selections. Split/Dual reporting can be selected byenabling dual reporting and enabling one of the split reporting options in field1●34. If option [1] is selected, all alarms, alarm restores and cancel repwts will go toboth phone numbers, while all other reports will go to the secondary phonenumber. If [2] is selected, open/close and test messages will go to both phonenumbers, while all other reports will go to the primary phone number. Folbwing arethe Split/Dual Reporting options:Reporting Field NumberFormat ●51 1*34 Where Reports GoDual 1 0 All reports to both num.Split o lor2 1-alarm, alarm restore &

cancel to primary, allothers to secondary.2=open/close, test tosecondary, all others toprimary.

Split/Dual 1 lor2 1-alarm, alarm restore &cancel to both, all othersto secondary only.2=open/close to both, allothers to primary only.

ADEMCO LOW SPEED is a pulsed format which responds to a 1400 Hzhandshake and kiss-off, and transmits data with 1900Hz pulse tones @ 10pulses per second (pps), A typical message consists of two rounds which mustbe verified by the receiver. A complete standard report consists of either a 3 or 4-digit account number followed by a 1-digit alarm code. Though 2 rounds are sent,only the valid report is displayed.In expanded reporting, two messages are sent, two rounds per message, the firstbeing the account number and alarm cwde, the second being the zone ID code towhich the alarm was assigned. A complete expanded report consists of a 3 or 4-digit account number followed by a 1-digit alarm code, then the alarm code isrepeated, followed by the channel number.EX. Standard: CCCC E where: CCCC = account number

Expanded: CCCC E E = event codeEEEE Z Z = zone ID code

Standard and expanded reporting in the SESCOA/RADIONtCS format is virtuallythe same as ADEMCO Low Speed except for the following:1, The handshake and kiss-off frequency is 2300 Hz.2. The data is transmitted with 1800 Hz pulse tones.3. The rate of transmission is 20 pps.

A 4+2 report consists of a 4-digit account number and a 2-digit alarm code, orevent code. 4+2 reports can be accomplished either in ADEMCO Low Speed (1Opps), or SESCONRADIONICS (20 pps) format.In 4+2 reporting a unique 2-digit code for each zone is reported. A 4-digitaccount number followed by a 2-digit code is sent, where the first digit is theactual event, such as in ALARM, RESTORE, or TROUBLE, etc., and the seconddigit of the code represents the “zone” where the event occurred. (but notnecessarily the actual zone number). Each code in itself is unique to a specificzone. If desired, the actual zone number can be reported by entering thecorresponding 2-digit zone number (ex. zone 1= [0] [1]; zone 63= [6] [3]). Areport might appear as:1 234 59 (“5 9“ might be a unique “TROUBLE RESTORE, ZONE 25).

-49-

Page 50: ADEMCO manual 4140

4+2 Hxpress ADEMCO’S Express format provides the same information as the 4+2 format, butwith three differences:1. The data is transmitted in DTMF (Dual Tone Multi-Frequency, known as ..-

“TouchTone”, at the rate of 10 characters per second). This greatly decreasesthe time it takes a report to go through to central station. An average 4+2 Low wSpeed report might take as long as 20 seconds to complete its report, but4+2 Express takes under 3 sees.

2. Two message rounds are eliminated by the use of a checksum digit. Insteadof the communicator sending 2 rounds per report, it sends only 1 round witha checksum digit at the end. Doing this also helps in decreasing the time ittakes for a report to be sent.

3. The handshake frequency is 1400 Hz followed by 2300 Hz, and the kissofffrequency is 1400 Hz.

Memco High Speed ADEMCO’SHighSpeedformattransmitsdata in DTMF at a rate of 10 characters perReporting second. The handshake frequency is 1400 Hz followed by 2300 Hz, and the

kissofffrequencyis 1400 Hz. The messagecontains13 digitsas follows: A 4-digitaccountnumber + eight channelsof zone information(l-8 or duress plus 9-15) +one statuschannel,which identifiesthe type of events being reported in the eightzone locations. Atypical High Speed report will be kissed off in under 5 seconds.Channels 1 through 8 could have one of the following conditions:

1 = NEW EVENT2 = OPENING (Status Channel Always= 2)*3 = RESTORE4 = CLOSING (Status Channel Always= 4)*5 = NORMAL, NO EVENT TO REPORT6 = PREVIOUSLY REPORTED, NOT YET RESTORED

● NOTE: Channel 1 will contain the user ID 1-9, A-F if Open/Close reporting isenabled.The status channel might have one of the following conditions:

1 = DURESS (For Duress Plus Channels 9-15 Only)2 = OPENING3 = BYPASS (For Channels 1-8 Only)4 = CLOSING5 = TROUBLE (For Channels 1-8 Only)6. SYSTEM STATUS: sAC LOSS in Channel 1

● LOW BAITERY in Channel 2● PROGRAM TAMPER in Channel 3“ POWER ON RESET in Channel 4

7. NORMAL ALARM STATUS (Chnls 1-8 Only)9 = TEST REPORT

A typical high speed report may look as follows:123451155555 7(Acct#1234 with alarms on channels 2 and 3)

High Speed Format Limitations1. When using Ademco high speed, remember there are only 15 channelsavailable, plus a duress channel. If more than 15 zones are being used, they willhave to share channels.2. With Ademco High Speed reporting, channels 9-15 cannot report troubles orbypasses. Use these channels for zones that will not report these conditions.

-50-

Page 51: ADEMCO manual 4140

Contact ID Reporting This is the only format that can identifyall 87 protectionzones by their uniquezone (Contact) ID numbers, and providesa 1-digit event qualifier and 3-digit,specifically defined event code which quickly identifies the condition beingreported.Contact ID repofis in DTMF (Dual Tone Multi-Frequency@ 10 characters persecond)and respondsto a 1400 Hz followedby 2300 Hz handshake,and a 1400Hz kissoff.Thisformatalsouseschecksuminsteadof two messageverification.Acomplete reporttakes under 3 seconds.

ContactID Reportingtakesthe format: CCCC Q EEE GG 222 where:Cccc = Customer (subscriber) number.Q= Event qualifier, where: E=new event(1) and R= restore (3)EEE = Event code (3 hexadecimal digits), defined in the table on the

next page.= Partition number.

s= Zone/contact ID number reporting the alarm (001-099), or usernumber (001-099) for openklose reports. System status messages(AC Loss, Walk Test, etc.) contain zeroes in the 222 location.

TABLE OF CONTACT ID EVENT CODESCode Definition Code Definition110 FireAlarm 401 O/C By User121 Duress 403 Power-UpArmedInn e:laA n--:.. 7 AnR P.amalh I -1L& am N rcu uu

123 Audible Panic131 Perimeter RI1“-I=R’132 Interior Bb,133 24 Hour BLIi134 Entry/Exit BI

135 D-.,f~l:-b.$m

150 2,301 A~ LUSS302 Low System B305 System Reset306 ProgramTamp309 B-+*-’ ‘A* ‘r332 Pull l-vu333 R~ m-!

IvglaryI‘rglary

lurglaty~dyll~lylu durglary!4 Hour Auxiliary- I ---

Iatterv

)aucl y I ==1 I ail‘-” ‘ ‘-p Short-TroubleI r m~~iver Failure-Trouble“-- ‘ ‘m Trouble

I 004 I nr II

Qlfihd\

c’ ‘-wvisic- m - RF1c’ ‘nerviSiOn

~a!lperI ~i M I der Low Batterv

7“” , “-.-w,”, user407 ] Remote Arm/Disarm (Download) I

I

452 I late open/close453 I Fail to open

[Ulun nl 1 I 1

‘switch O/CI back Requested

STAV

it Mode I

I. . . . ... ..te Reset

131 I Exception schedule change32 I Access schedule chanae

ADVISORY: Ademco’s new Contact ID reporting is capable of uniquely reporting all 87 zones of information, aswell as openings and closings for all 128 users, to central stations equipped with the Ademco 685 receiver usingsoftware level 4.4 or higher. Must be level 4.6 to fully support all new 4140XMPT2 report codes. 685 softwarelevels below 4.4 cannot support Contact ID reporting. For information regarding updating the 685 receiver,contact the Technical Support group at 1-800-645-7492 (NY) or 1-800-458-9469 (CA)

-51-

Page 52: ADEMCO manual 4140

UsEn@Test Mod. After the installationis completed, the Security System should be thoroughlytestedon a partitionby partltlcnbasisas follows:1, With the System in the disarmed state, checkthat all zones are Intact, If *

DISARMED - Press [*] to show faults b displayed, press the ~] key to displaythe descriptors of the faulted zone(s), Restore faulted zone(s) If necassary, sothat *“’DISARMEIY** READY TO ARM Is displayed,

2, Enter the security code and press the TEST key, The external sounder (Ifused) should sound for 3 seconds and then turn off (the system Is operatingon the back-up battery only at this time).

NOTE 1, If the sounder does not sound, this maybe an indication that the backupbattery Is discharged or missing.NOTE 2, As a reminder that the system is kr the Test mode, the Console willsound a single beep at 15-second intervals if no protection zones are violated.NOTE 3, In the Test mode, no alarm reports will be sent to the central statbn,Alec, the external sounder (if used) will not be activated,Doors and WindowsOpen and close each protected door and window in turn. Each action shouldproduce three beeps from the Console, The descriptor for each prctectbn zonewill appear on the Console display.

Motion DetectorsWalk in front of any interior motion detectors, Listen for three beeps when thedetector senses movement. While it is activated, its descriptor will remaindisplayed on the Console. Note that wireless PIRs will have a 3 minute lockoutbetween transmissionsto conserve battery life (remove cover for walk test tooverridethe 3-minute lock-out).

Smoke DetectorsFollowthe test procedureprovidedby the manufacturerof each smoke detector _to ensure that all detectors are operational and are functioning properly.NOTE: A 2-wire smoke detector display will not clear until the Test mode is exited.

Turning Off TEST modeEnter the securitycode and pressthe OFF key.

Armed System Test iMPORTANT! A message wili be sent to the centrai station during the foiiowingtests. Notify the centrai station that a test will be in progress.

NOTE: A display of “COMM. FAiLURE” indicates a failure to communicate (noKissoff by the receiver at the central station after the maximum number oftransmission attempts is tried). if this occurs, verify that the phone iine isconnected, the correct report format is programmed, etc.

1.

2.

3.

Arm the system and fault one or more zones. Siience aiarm sounder(s) eachtime by entering the code and pressing OFF. Check that Entry/Exit deiayzones provide the assigned deiay times.

Check the keypad-initiated aiarms, if programmed in fieid ’05, by pressing thePanic key pairs (~] + [1], [#] + [3], ~]+ [#]). if the system has been programmedfor audibie emergency, the consoie wiil emit a ioud, steady aiarm sound. Theword ALARM and a descriptor “99” wiii be displayed for ~] + [#]. (if ~] + [1] ispressed, a “95” wiil be dispiayed; if [#] + [3] is pressed, a “96 wiii bedisplayed). Siience the aiarm by entering the security code and pressing OFF.if the system has been programmed for siient panic, there wili be no audibieaiarms or dispiays. A report will be sent to the centrai station, however.Notify the central station that aii tests are finished and verify results with them.

-52-

Page 53: ADEMCO manual 4140

Turning The System 1. Fullyexplainthe operationof the systemto the user by goingover each of itsOver To The User functionsas wellas the Usets Manualsupplied.

2. In particular, explain the operation of each zone (entry/exit, perimeter,interior, fire, etc.). Be sure the user understands how to operate anyemergency feature(s) programmed into the system.IMPORTANT!: In the spaces provided in the User’s Manual, record theEntryand ExitDelay times, and thosefunctionsthat have been programmedintothe f@l~fe pairsof PANIC key pairs(r]+ [1], [#]+ [3], r] + [#]).

3. Make surethe user understands the importance of testing the system at leastweekly, folbwing the procedure provided in the Usets Manual. -

ITO THE INSTALLER

IRegular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital tocontinuous satisfactory operatbn of any alarm system.

The installer should assume the responsibility of developing and offering a regular maintenance program to theuser as well as acquainting the user with the proper operatbn and limitations of the alarm system and itscomponent parts. Recommendations must be incfuded for a specific program of frequent testing (at least weekly)to insure the system’s proper operation at all times.

-53-

Page 54: ADEMCO manual 4140

UL INSTALLATION REQUIREMENTSThe following requirements apply to UL Residential Burglary installations:1. All partitions must be owned and managed by the same person(s).2. All partitions must be part of one building at one street address,3. The audible alarm device(s) must be placed where it/they can be heard by all partitions.4. The Control cabinet must be protected from unauthorized access. This can be done by installing a tamper switch on the

cabinet door (not supplied with 4140XMPT2) or by installing a UL Listed passive infrared detector positioned to detectcabinet access. Wire the selected device to any EOLR supervised zone (zone 1-8). Program this zone for daytrouble/night alarm (type 05) or 24 hour audible alarm (type 07) response. The 24 hour alarm response must be used formultiple partitioned systems.

5. Remote Downloading and autodisarming are not UL Listed features.

“FEDERAL COMMUNICATIONS COMMISWON (FCC) STATEMENT”This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the followingstatement for your information:This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordancewith the manufacturer’s instructions, may cause interference to radio and television reception. It has been type tested andfound to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules,which are designed to provide reasonable protection against such intederence in a residential installation. However, there isno guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio ortelevision reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct theinterference by one or more of the following measures:

● If using an indoor antenna, have a quality outdoor antenna installed.● Reorient the receiving antenna until interference is reduced or eliminated.● Move the receiver away from the cxmtrol/mmmunicator.● Move the antenna leads away from any wire runs to the control/communicator.● Plug the controlkommunicator into a different outlet so that it and the receiver are on different branch circuits.

If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions.The user or installer may find the following booklet prepared by the Federal Communications Commission helpful:

“Interference Handbook”This booklet is available from the U.S. Government Printing Office, Washington, DC 20402.The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions orUser’s Manual. Unauthorized changes or modifications could void the user’s authority to operate the equipment.

IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMSIntheeventof telephoneoperationalproblems,disconnectthecontrolpanelb removingtheplugfromtheRJ31X (CA3SAinCanada)walijack. We

krecommendthatyoudemonstratedsconnedng thephonesoninstallationof e system.DonotdisconnectthephoneconnectioninsidetheControlPanel. Doingsowillresultinthelossofyourphonelines. If theregularphoneworkscorrectlyaftertheControlPanelhasbeendisconnectedhornthephonelines,theC@rol Panalhasa problemandshouldbe returnedforrepair. If upondisconnectionoftheControlPanel,thereisstilla problemontheline,notify the telephone company thattheyhavea problemandrqest promptrepairservice.The usermsynotunderan citwmstances(i or

Loutofwarrantv)atterrmtanysstvicaor rsmairstothesystem.Itmustbe returnedtothefactcxyoranauthciizedsarvicaagency railrepairs.. ..-

FCC PART 68 NOTICErhis equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among]ther information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, thisnformation must be provided to the telephone company.rhis equipment uses the following jacks:

An RJ31X is used to connect this equipment to the telephone network.The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs on theIelephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of theRENs should not exceed five (5.0). To be cetiain of the number of devices that maybe connected to the line, as determined bythetotal RENs, contact the telephone company to determine the maximum REN for the calling area.If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporarydiscontinuance of service may be required. If advance notice is not practical, the telephone company will notify the customeras soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe necessary.The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect theoperation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make thenecessary modifications in order to maintain uninterrupted service.If trouble is experienced with this equipment, please contact the manufacturer for repair and warranty information. If thetrouble is causing harm to the telephone network, the telephone company may request you remove the equipment from thenetwork until the problem is resolved.There are no user serviceable components in this product, and all necessary repairs must be made by the manufacturer.Other repair methods may invalidate the FCC registration on this product.This equipment cannot be used on telephone company-provided coin service. Connection to Party Line Service is subject tostate tariffs.This equipment is hearing-aid compatible.When programming or making test calls to an emergency number, briefly explain to the dispatcher the reason for the call.Perform such activities in the off-peak hours; such as early morning or late evening.

-54-

Page 55: ADEMCO manual 4140

(DOC) STATEMENT

NOTICEThe Canadian Department of Communications label identifies certified equipment. This certification means thatthe equipment meets certain telecommunications network protective, operational and safety requirements. TheDepartment does not guarantee the equipment will operate to the user’s satisfaction.

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of thelocal telecommunications company. The equipment must also be installed using an acceptable method ofconnection. In some cases, the company’s inside wiring associated with a single line individual service may beextended by means of certified connector assembly (telephone extension cord). The customer should be awarethat compliance with the above conditions may not prevent degradation of service in some situations.

Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by thesupplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give thetelecommunications company cause to request the user to disconnect the equipment.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephonelines and internal metallic water pipe system, if present, are connected together. This precaution may beparticularly important in rural areas.

Caution: User should not attempt to make such connections themselves, but should contact the appropriateelectric inspection authority, or electrician, as appropriate.

The ~ (LN) assigned to each terminal device denotes the percentage of the total load to beconnected to a telephone loop which is used by the device, to prevent overloading. The termination on a loopmay consist of any combination of devices subject only to the requirement that the total of the Load Numbers of allthe devices does not exceed 100.

AVISLWiquette du minist?xe des Communications du Canada identifie Ie mat&iel homologu6. Cette 6tiquette certifieque Ie mat6riel est conforme A certaines normes de protection, d’exploitation et de s6curit6 des r6seaux det616communications. Le ministbre n’assure toutefois pas que Ie mat6riel fonctionnera ~ la satisfaction deI’utilisateur.

Avant d’installer ce mat6riel, I’utilisateur doit s’assurer qu’il est permis de Ie raccorder aux installations deI’entreprise locale de tdk%ommunications. Le mat4riel doit 6galement ~tre instal16 en suivant une mdthodeaccept6e de raccordement. Dans cerlains cas, Ies fils intt$rieursde I’entreprise utilisds pour un service individual ~la Iigne unique peuvent i3tre prolong6s au rnoyen d’un dispositif homologud de raccordement (cordonprolongateur t616phonique interne). L’abonn6 ne doit pas oublier qu’il est possible que la conformit6 auxconditions 6nonc6es ci-dessus n’empbchet pas la degradation du service clans certaines situations.Actuellement, Ies entreprises de t616communications ne permettent pas que I’on raccorde Ieur matt%iel auxprises dabonn6s, sauf clans Ies cas precis pr6vus par Ies tariis particuliers de ces entreprises.

Les reparations du mat6riel homologu6 doivent ~tre effectu~es pas un centre d’entretien canadien autorisdd6sign6 par Ie fournisseur. La compagnie de t61&ommunications peut demander ~ I’utilisateur de ddbrancher unappareil h la suite de reparations ou de modifications effectu6es par I’utilisateur ou ~ cause de mauvaisfonctionnement.

Pour sa propre protection, I’utilisateur doit s’assurer que tous Ies fils de mise en terre de la source d’dnergie61ectrique,des Iignes t616phonques de rt%eau de conduites d’eau s’il y en a, soient raccordc%ensemble. Cetteprecaution est parliculibrement importanceclans Ies r%gionsrurales.

Avertissement: L’utilisateurne doit pas tenter de faire ces raccordementsIui-mi?me;il doit avoir recours~ UPserviced’inspectiondes installationsdlectriques,ou h un 61ectricien,selon Ie cas.

e de _(lC) assign~ A chaque dispositif terminal pour t%iter toute surcharge indique Ie pourcentage dela charge totale qui peut etre raccordd ~ un circuit tdk$phonique bouck$utilisd par ce dispositif. La terminaison ducircuit boucld peut 6tre constitute de n’importe quelle combinaison de dispositifs, pourvu que la somme de:indices de charge de I’ensemble des dispositifs ne d6passe pas 100.

-55-

Page 56: ADEMCO manual 4140

DIP SWITCH TABLES FOR ADDRESSABLE CONSOLES AND POLLING LOOP DEVICES

Addressable Consoles 4208 Zone Expander 4196PIR 4275 PIR

~~~ HOFI p sH~TFo20SHOWN SET

ID 10-16 (A) SIDE

Ifi\:fj phtl

I

‘%l%l:fj &l: ~

Ir

1

POS, 1: LOOPS 1 & 2 1

RESPONSE TIMEPoS.1 : MUST BE UP -i--

t IMPORTANT: USE ID 31 FOR POS6: UP (A), dn (B) = INST. MODE

APPLICATIONS NOT REQUIRING wtAOLEEAsIaQw dn (A), UP (B) = PULSE COUNT

ADDRESSABLE CONSOLES. A UP dnB

POS. 7: UP (A), dn (S) = WALK TEST

dn UP dn (A), UP (B)= Wn DISABLE

DIP SWITCH POSITION THIS TABLE FOR 9(P SW8TC”P0S8y10t! THIS TABLE FOR OIPSDEVICE

DEVICE

ID 1 2;3\4\5 DIPSWITH2325678 WITH WORD “OFF”

o do dn Idn ]dn /dnWORD “OFF” “P UP up a. UP d“ LIP

UP’UP UP an UP on d. DIP SWITCH POSITION

1 do dn !dn Idn IUPUP UP UP a. an UP UP DEVICE

dn dndniUPDIP SWITCH POSITION 13 UP UP UP d- 0? UP d.

:dnID 1 !2!3 415

DEVICE: dn dndn; UP!UP

14 UP UP UP m 0. 0. UP

ID 15

4

UPIUP UP m c“ 0“ d“

23 4 510 dn iUP!dn UPdn

!dn dnl UP; dnldn 16 ,UP, UP e. w UP UP UP

511

\dn dni UP; dn!UP,7 ,UP’UP d. UP UP UP ‘an

dn UPldn:UPIUP’

6 dn dnUP!UP!dn10-16 dn dn dn UP 18 UP UP a. UP UP 0“ UP 1

4

12

17-24

dn luP; UPdn, d”

dn dn UP dn 19 uP w m UP uP 0. m

jdn dnl UP: UP!UP13 ,dn ‘UP~UP. dnUP

7 UP UP on UP an UP UP

8 ldn UPldn, dn>dn 25-32 dn dn UP UP14 dn !UP’UP UPdn

$? UP UP an UP 07 UP d. 15 dn UP UP UP UP

9 dn UPldnldn UP 33-40 dn ! UP Idn!dn 22 UPUP 0. UP 6- d-, UP23 UP UP a. UP da an an 18

10 dn UP!dn WP\dn 41-48UP dn cm ,dn ldn

dn ! UP dn I UP 24 UP UP en d? UP UP u? 17

11 ,do UP; dnl UPIUPUP dn dn d. IUP

49-56 dn i UP UP! dn 25 UP UP on d? UP UP an 18

12 dn UPUP dn idn 26 UP UP d. 6. UP d. UPUP dn idn UPidn

57-64 dn UP UP] UP -19

13 Idn UPIUP dn’UP27 UP UP e. e. UP an an

UP dndn’UP)UP

65-72 lUP, dn dn ] dn 28 UP UP m d. d“ UP UP 20

14 dn UP, UP UPldn

UP, dn]UPdnldn29 UPUP 0. an 6. UP .5. 21

15 Idn UPi UP UPUP 73-so lUPldn dn I UPUP dn jUPdn IUP

UP UP 0“ 0. d“ an UP 22

16

‘U P,dn/UP’UP’dn

tUP’dn[dn’dn dn 61-S8 I UPIdn UPidn :? UP UP an~on d. 6.32 UP d“ UP UP UP UP>P+

23

17 I UP dn!dndn UP

UPldnl UP UPIUP

33 UP 00 UP UP UP UP an 24 UP i UPldn dn ldn

16 / UP dn Idn lUP’dn 34 UP d. UP UP UP on UP 25

19

UP\ UPidn dn IUP-

[ UP dn, dn UPUP 35 UP d. UP UP UP d. m 26

20

UP IUPldn UP,dn -

IUP dnl UP, dn’dn THISTABLEFOR36 UP d. UP UP on UP UP 27 UPIUPldnU PIUP

!UUP cm UP UP an UP an

dn[UPldn UP :: 26 UP! UP IUP, dn dn

2: Iu DIPSWITH UP on UP UP an 6. UP

P dnl UP IUPdn w 6“ UP w m en m

B : “p .nx.~i

29 UPi UPi UPdnl UP

23 !UP dnl UP UPUP WORD“ON” UP a“ UP on UP UP UP 30 UP, UP IUPUP~dn

24 I UP UPldntdndn 4231

UP 6. UP m UP an UPUP; UP, UP, UP’UP

25 [ UP UPidn ldn UP DIP SWITCH POSITION 43 UP d“ UP d? U. d“ an

26 IUP UP[dni UPldn DEVICE 44 UP d. UP d. 0. UP UP

27 lUP’UPidni UPIUP 1045 UP on UP an en UP d.

26 23;4 s46

UP UP! UPidn IdnUP an ,UP on d. on UP.

47 UP an UP c“ d“ on d“ THIS TABLE FOR DIPS29 Iu P UP IUPldnl UP 10-16 UP UP I UP dn 48 #uPm O.uPuP uPuP.

UPi UP[UP[dn 17-2449 UP d. en UP UP UP an WITH WORD “ON’$

UP UP I dn UP31 u IUP, UP, UP

50 1UP dn ,0. UP UP m UP Bt 25-32 UP UP; dn dn up dqO” UP UP m 0.

;[LuE:11:6~412!1

51

33-40 UP dn I UP UP52 UP .2”,0” UP 0. UP UP

DEVICEDIP SWITCH POSITION

53 UP d“ d“ UP 0. UP 0“

41-48 UPldn\UP dn M UP 0. tin UP d“ d“ UP ID 1;2,34’5

49-56 UP!dnldn UP65 UP m an UP m d. d.

_% UP ‘d. m“ an UP UP UP 1057-64 UPidnldn dn

UP dn UP dn UP57 UP 6. an an UP UP d.58

11 UP dn UP I dn dn

65-72 dn jUP!UP UPUP d. .0. m dP d. UPUP d“ tin U, UP 0“ d“ 12 UP, dn dn UP UP

73-80 dn \UP[UP dn E UP an an a. ar UP UP 13 UP dn dn ,UPldn

61 -S6 dn :UPldn UP01 UP an dn d. .? UP d. 14 UP I dn dn d“ IUP62 UP d“ d“ an 0. 0“ UP63

15;UP 0. d. d“ m an d.

UP I dn dn dn ,dn

64 d“ UPUP UP UP UP UP16 dnj UP UP UPIUP

65 an UP UP UP UP UP en 17 tdn iUP UP UP !dn

66 ,d: :Pyfy uP On UP 1667

‘dnl UP UP dn iUPo UP on ar 19 dn I UP UP dn !dn

68 d. UP UP U. m uP_uP6S an UP UP u. on UP on

20 dn j Up d“ ,UP)UP

70npppnd“ UP UP UP 0. d“ UP 21 dn t UP dn ‘UPldn

71 0 d d 22 dn I UP dn $dn IUP72 an UP UP 0“ UP J u?= 2373

dn ! UP dn dn Idnm UP uPzuP UP on

7 d. UP UP w UP 0. LIP24 dn ,dnl UP! UP; UP

7: 0“ UP UP a. UP 0“ 0“ 25 dn, dn UP, UPdn~ _ an UP UP 0. or u~u~. 26 ,dn Idn UP’dn UP

77 d“ UP UP 0. . . UP d“ J 2778

dn dn UPdn dnOn UP UP 0. 0. d“ UP ;

7928

d. UP UP 0- 0. e. 0.dn dn dn UP UP

SD On UP d? UP ui= “LU_P_ 29 dn dn d(l UP d“

.99 d. UP a“ UP v~uP~ 30 dn d“ ,d” d! UPo! UP d. u. u.gu~ 31 dn ‘dn, dn d. d.

63 __ _d. UP 0, “0 1-1. an an84 d- UP 0. UP on W= UP

BIT

-BL_dLuy+Lw M-QLVALUE 1684 21

n . Unun87 on _ujlO”_w XL..O..>...SS d? XY.Q~.C—_ C?_UP !! _w .5” UP 0. . . ‘JD UP .3”

BITVALUE 643? 16! <2,

56-

Page 57: ADEMCO manual 4140

4192SW41 92SDT/ 4190WH Zone Expander4192CP

~ctoi n

— Ie e t

1iPPLIES TO TABLE A ONLY SIDE APPLIEB TO TASLES A & B

SHOWN SEr FOR ID 10 VIEW SHOWN SET FOR ID 10(A)(UP)

fm]g f@::~

T (dn)1 SIDE

POS. 1: MUST BE dn WITH TABLE A B VIEWPOS.1 MUST BE dn UP (d.)

4278 PIR

SHOWN SET FOR ID 10--‘12345678

m: .

130S7; UP= NORMAL MOOE

dn = INSTANT MOOE

~OS.8: UP= W/T OISABLEdn =WALK TEST

J1SIOEVIEW(dn)

DIP SV.ITC” POSR,ON

DEVICE

10 1 2!2456

10 UP UPldn UP d. UP11 UP UPldn UP an en12 UP UPldn d. UP UP13 I UP UPldn dn UP dn14 I UP UPidn dn d. UP15 I UP LJPldn dn an an16 lUPidnlVPUP UP UP17 lUPldn !UP UP UP dn18 lUP[dnlUP UP d“ UP*9 UP!dnl UP UP d. d.20 UPldnlUPdn UP UP21 UPldn ‘UPdn UP dn

UPldn ,UPdn d. UP:: UP,dn IUP d. d. d.24 UPldn id. UP UP UP.25 UPld. id. UP UP d.26 iUPldn Id. UP d. UP2? lUPldn d. UP 6. d.28 f UP d. Id. d. UP UP29 I UP d. Id. d. UP an30 , UP d“ d“ d“ d. UP31 ! UP d. Id. d. d. On32 I dn UP UP UP UP UP33 Id. UPVP UP UP d.34 I d“ IUP, UP UP 0“ UP35 I dn UPIVP UP d. d.26 I dn UP, UPdn UP UP37 ! dn UPIVP d. UP d.22 I d. UP, UP d. d“ UP39 I dn UPIUP do d“ d.40 id. UP,dn UP UP UP

id. UPldn UP UP 6.:2 1cm UPldn UP an UP43 ! d. UPmdn UP 0. d.44 ldnlUPdn d. UP UP45 Id” lUP,dn d. UP an46 ld. lUP,dn d. 6. UP47 d. UP,dn do d. d.48 I an d. IUP UP UP UP49 Id. d. IUP UP UP en50 , d. dn ‘UP UP d. UP51 I dn d. IUP UP .5. d“52 ! d. dn, UP d. UP UP53 Id. d. ‘UP d. UP d.54 d. d. MP d. an UP55 d. d. IUP 0. d. d.56 dn d. Id. UP UP UP

57 dn d. Id. UP UP d.58 dn d. d. UP d. UPw Id. d. ldn UP d. d.60 I d. d“ ,dn d. UP UP61 i d“ {d. Id” d. UP dn

id. Id. Id. d. d. UP:: Id. id. Id” .5. d. d.

BITVALUE ~32!16 8 4 2 1

1500 Glassbreak Detector

0

(3(2~.

@

SHOWN SET FOR ID 10

12345678

e::aT SIOE

POS. 1 MUST BE UP VIEW(dn)

4194 Reed Contact(Surface Mount)

SHOWN SET FORID1O

?ciP SWITCHP03mmN

DEVICE

ID1 ,2 3456

10 dn dn UP d. UP dn17 an dn UP dn UP, UP12 d. d. UP UP d. dn13 dn dn UP UP’dn UP14 dn d. UP, UP UP, dn15 dn dn UP UP UP’UP16 d. ;UP d. d. d. d.17 dn IUP dn dn dn UP18 d“ UPd. dn UPd”

d. UPldn d. UP’ UP”: dn UPldn UP dn d.21 d“ UP d. UP d. UP22 d. UP d. UP UPdn23 d. UP .5. UP UP UP24 d. UP UP d. d. d.25 d. UP UP d. dn UP26 d. UPKJP d. UP d.

d. UPIUP d. UP UP.z d. UPIUP UP d. dn29 d. UP IUP UP d“ UP30 d. UPIUP UP UP d“31 dn UPWP UP UP UP32 UP d. Id. d. d. fdn33 UP d. idn d. d. UP34 UP d. id. 0. UP dn

UP 6. ion dn UP UP3 UP dn Id. UP d. dn

UP d. id. UP dn UPz UP d. Idn UP UP dn39 UP d. ien UP UP UP40 UP ldn UP d. do d“41 UP Id. UP d. d“ UP42 UPId. UP d. UP d.43 UP (d. UP d. UP UP44 UP ‘dn UP UP d. d.45 UP dn iUP UP d“ UP46 UP d. IUP UP UP d.47 UP d. IUP UP UP UP46 UP UP Idn d. d. d.49 UP UP [d. d. d. UP50 UP uPidn d. UP d.51 UP UP d. dn UP UP52 UP UP d. UP dn dm53 UP UP d. UP d. UP54 UP UP dn UP UP d.55 UP UP dn UP UP,UP56 UP UP UP d. d“ ,dn57 UP UP UP d. d. UP58 UP UP UP d. UP d.59 UP VP UP d. UP UP60 UP UP UP UP dn d.61 UP UP UP LIP dn UP62 UP UPIUP UP UP!dn63 UP UPIUP UP UP’UP

Rn II-.VALUE 321@9 4 2 1

7500 Glassbreak Detector

,Q

oc

m

m

SHOWN SET FOR 1010

1234567S

m~aT SIOE

POS. 1 MUST BE: UP VIEW

FOR DIP SWITCH SEITINGS,USE TABLE B ABOVE LE17

-57-

Page 58: ADEMCO manual 4140

DIP SWITCH TABLES FOR WIRELESS DEVICES

-58-

Page 59: ADEMCO manual 4140

SUMMARY OF SYSTEM COMMANDS

Event LoggingCommands

Wireless SystemCommands

User Code Commands

Keypad Functions

ProgrammingCommands

Scheduling Commands

Device Control (X-1 OOr Relay)

Event Log Display=Code+[#] + 60Event Log Print=Code + [#] +61 (installer only)Clear Event Log Code + #+ 62 (Installer Only)

House Id Sniffer Mode=Code + [#] + 2 (installer only)Transmitter Id Test= Code+ [#]+ 3 (installer only)Go/No Go Test=Code + 5 (Test Key)

Add A User Code.User Code +8+ New User Number+ New User’s CodeChange A Code=User Code + 8 + User Number+ New Usets CodeDelete A Usets Code=Your User Code + 8 + User Number To Be Deleted + Your CodeAgain

View User Capability= User’s Code + ● + ●

Set Real-Time Clock (Installer, Master Only)=Code + # +63

Arming AwayArming StayArming InstantArming MaximumQuick Arm

Global Arming

DlsarmlngBypassing Zones

Quick BypassChime Mode

Enter Code + Away [2].Enter Code + Stay [3].Enter Code + Instant [7’j.Enter Code + Maximum [4].Use # Key Instead Of User Code Followed ByAny Of The Above Arming Mode Keys.If Enabled For The User, The Console Will Display APrompt. Answer The Prompted QuestionsEnter Code + Off [1].Enter Code + Bypass [6] + Zone Number. ToAutomatically Bypass All Faulted Zones, Use

“Quick Bypass” Method: Enter Code + Bypass+ [#].Enter Code + Chime [91.To Turn Chime Mode Off, EnterCode + Chime Again.- -

Partition Goto= User Code + ● + Partition Number O-8Goto Home Parltion=User Code + ● + OPanics “+1 Zone 95 (A Key)

*i-# Zone 99 (B Key)#+3 Zone 96 (C Key)

View Downloaded Messages= Press OFor 5 SecondsDisplay All Zone Descriptors=Press ● For 5 SecondsDisplay User Self Help= Hold Any Key For 5 Seconds

Site Initiated Download=User Code+ # + 1Direct Wire Dowload Enable= User Code+ # + 5Enter Program Mode=installer Code+ 800Exit Program Mode=*99 Or ●98

Installer Programmed Schedule Events=lnstaller Code+ # + 80Tempora~ Schedule Editing=User Code + # + 81 (Installer, Master, Manager

Only)Extend Closing Window=User Code+ # + 82 (Installer, Master, Manager Only)End User Output Device Programming=User Code+ # + 83

Actviate Output Device As Programmed =User Code+ # + 71Actviate Output Device As Programmed =User Cede+ # + 72Activate Access Relay For Current Partitiin=User Code+ O

-59-

Page 60: ADEMCO manual 4140

4140XMPT2 CONTROLPhysical: 12-1/’2”WX14-1/2”HX3”DElectrical:VOLTAGEINPUT

ALARMSOUNDEROUTPUT

AUXILIARYPOWEROUTPUT

BACK-UPBAllERYSTANDBY:CIRCUITPROTECTORS:

wFromAdemcaNo.1361Plugln Transformer(use1361CN inCanada)or 4300transformer(forX-1Oinstallations)rated16.5VAC,40 VA.1OVDC-13.8VDC,2.8 ampsmax.(UL1023,UL609installations),750mAiessaux.currentdraw(UL965installations).9.6VDC-13.8VDC,750mAmax. For UL installations,the accessoriesconnectedto the outputmust be ULListed,and ratedto operatein the abovevoltagerange.12VDC,4AHor 7AHgeiceil. YUASANP4-12 (12V,4AH)or NP7-12(12V,7AH)recommended.4 hours min. with 750 mA aux.bad using 7 AH battery.thermal circuit breakera are used on battery input to protect against reverse batteryconnections and on alarm sounder output to protect sgainat wiring faults (Shorts).A solid state circuit breaker is used on auxiliary power output to protect against wiring faults(shorts).

DIGITAL COMMUNICATORFORMATSSUPPORTED:

ADEMCO HiGH SPEEDADEMCO 4+2 EXPRESSADEMCO LOW SPEEDADEMCOCONTACTIDSESCQARADIONiCS LOW SPEEDLiNE SEiZE: Double PoieRINGER EQUIVALENCE: 0.7BFCC REGISTRATION NO.: AC398U-68192-AL-E

4137AD/5137AD REMOTE CONSOLESPhysical:

Width: 8.4 inchesHeight: 4.75 inchesDepth: 1.1 inches

Electrical: Voltage input: 12VDCCurrent Drain: 60 mA (4137AD)

90 mA (5137AD)Interface Wiring:

RED: 12VDC input (+) auxiiiary powerBLUE: Not UsedGREEN: Data to control panelYELLOW Data from control panelBLACK: Ground and (-) conndion from supplemental

power supply.

6139 Remote ConsolePhysical:

Width: 6.25 inchesHeight: 4.75 inchesDepth: 1.25 inches

Electrical: Voltage Input: 12VDCCurrent Drain: 100 mA

Interface Wiring:RED: 12VDC input (+) auxiiiary powerBLUE: Not i.hedGREEN: Data to controi paneiYELLOW: Data from controi panelBLACK: Ground and (-) connection from supplemental

power suppiy.

-60-

Page 61: ADEMCO manual 4140

L

I

(+:

;1+

@v

7Y;

.-.1[

do

ol

(leuJo

NA

sej)Z

*

ewo

dsau

olq

eum

mA

60Ad

-61-

Page 62: ADEMCO manual 4140

WARNINGITHE LIMITATIONS OF THIS ALARM SYSTEM

NhllethisSystemISan advancedwirelesssecuritysystem,if doesnotofferguaranteedprotection against burglary, fire orMhoremergen , Any alarmsystem,whethermmmerclalor residential,is subjectto compromiseor failureto warnfor a varl.

‘%tty of reasons, or example:Intrudersmaygain accessthrough unprotectedopeningsor havethe technicalsophisticationto bypassan alarmsensoror disconnect an alarm warning device.

I Intrusion detectors (e,g,, padve Infrared detectors), smoke detectors, and many other sensing devices will not work with-out power, Battery-operated devices will not work without batteries, with dead batteries, or If the batleries are not putInproperly, Devices powered aoiely by AC wiil not work if their AC power supply is cut off for any reason, however briefly,

‘ Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver, Even Ifthe signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved Into thepath,

I A user may not be able to reach a panic or emergency button quickly enough.~ While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not acti-

vate or provide early warning for a variety of reasons in as many as 35% of all fires, according to data published by theFederal Emergency Management Agency. Some of the reasons smoke detectors used in canjunctlon with this System maynot work are as folbws, Smoke detectors may have been improperly instalied and positioned. Smoke detectors may notsense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other sideof closed doors. Smoke detectors alsomay not sense afire on another level of a residence or building. A seccrndfloor de-tector, for example, may not sense a first floor or basement fire. Finally, smoke detectors havesensing Iimitations. Nosmoke detector cansense every kind of fire every time. In general, detectors may not always warn about fires caused bycarelessness and safety hazards iike smoking in bed, violent explosions, escaping gas, improper storage of flammablematerials, overloaded electrical circuits, children playing with matches, or arson. Depending on the nature of the fire and/orlocation of the smoke detectors, the detector, even if it operates as anticipated, may net provide sufficient warning to allowall occupants to escape in time to prevent injury or death.

o Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagramed in their installationmanual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of protec-tion, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion or in-trusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows. Mechanicaltampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical system can re-duce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the ambient tempera-ture of the protected area approaches the temperature range of 90° to 105°F (32° to 40°C), the detection performance candecrease.

● Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on theother side of closed or partly open doors. If warning devices are located on a different level of the residence from the bed-rooms, then they are less likely to waken or alert peopie inside the bedrooms, Even persons who are awake may not hearthe warning if the alarm is muffled by noise from a stereo, radio, air conditioner or other appliance, or by passing traffic. Fi-nally, alarm warning devices, however loud, may not warn hearing-impaired peaple.

● Telephone lines needed to transmit aiarm signals from a premises to a central monitoring station may be out of service ortemporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.

● Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protectthemselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropri-ately.

● This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed tolast as long as 20 years, the electronic components could fail at any time.

The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance. Thisalarm system should be tested weekly to make sure all sensors and transmitters are working properly. The security console(and remote keypad) should be tested as well.Wireless transmitters (used in some systems) are designed to provide iong battery life under normal operating conditions.Longevity of batteries may be as much as 4 to 7 years, depending on the environment, usage, and the specific wirelessdevice being used. External factors such as humidity, high or low temperatures, as well as large swings in temperature, mayall reduce the actual battery life in a given installation. This wireless system, however, can identify a true low battery situation,thus allowing time to arrange a change of battery to maintain protection for that given point within the system.Installing an alarm system may make the owner eligible for a lower insurance rate, but an alarm system is not a substitute forinsurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and continusto insure their lives and property.

We cmtinue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their lovedones to learn about these developments.

-62-

Page 63: ADEMCO manual 4140

ADEMCO LIMITED WARRANTY

Alarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiaries and affiliates(“Sellerm),165 Eileen Way, Syosset, New York 11791, warrants its products to be in conformance with its own plans andspecifications and to be free from defects in materials and workmanship under normal use and service for 18 months from thedate stamp control on the product or, for products not having an Ademco date stamp, for 12 months from date of originalpurchase unlessthe installationinstructionsor catalogsetsfortha shorter period, in which case the shorter period shallapply. Seller’s obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, anyproduct which is proved not in compliance with Seller’s specifications or provee defective in materials or workmanship undernormal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the product is altered orimproperly repaired or serviced by anyone other than Ademco factory service. For warranty service, return producttransportation prepaid, to Ademco Factory Service, 165Eileen Way, Syosset, New York 11791.

THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULARPURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO CASE SHALLSELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIALOR INCIDENTALDAMAGES FOR BREACH OF THIS OR ANYOTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILllY WHATSOEVER, EVEN IF THELOSSOR DAMAGE IS CAUSED BY THE SELLER’SOWN NEGLIGENCEOFtFAULT.Seller does not represent that the products it sells may not be compromised or circumvented; that the products will preventany personal injury or property loss by burglary, robbery, fire or otherwise; or that the products will in all cases provideadequate warning or protection. Customer understands that a properly installed and maintained alarm may only reduce the riskof a burglaty, robbery, fire or other events occurring without providing an alarm, but it is not insurance or a guarantee that suchwill not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NOLIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCTFAlLED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANYLOSS OR DAMAGE ARISING UNDER THIS LIMITEDWARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN,SELLER’S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT, WHICHSHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. This warranty replaces any previous warrantiesand is the only warranty made by Seller on this product. No increase or alteration, written or verbal, of the obligations of thisLimited Warrantv is authorized.

-63-

Page 64: ADEMCO manual 4140

INDEX1136134,601361CN34

224-hour Audible Alarm 1224-hour Auxiliary Alarm 1224-hour Silent Alarm 12

44+2 Express 504+2 Reporting 494100SM 5,45,484130PC 5,484137AD 5,30,35,604139SN 164142TR 26

X-10 2641465,244190354190WH 164191SN 164192CP 16,354192SD 16,354192SDT 16,35419416,35419716,3542045, 26420816,35427516,35427816,3542806, 17, 18,35428063354280-817,3542816, 184281/5881 174281H 174281L 174281M 1743002646422487-12488-1231

55137AD 5,7,30,35,60570065701215706215707215711215711WM 215715WH 2157162157272157752158006, 195801225802225802CP 2258032258062258072258162258172258272258492258816, 185881H 175881L 17

-64-

5881M 17589022

661395,7,30,35,6067523,35

7702327193274032747327720237920SE 23

AABB1031 32AC Loss Reporting 7AC Outlet Ground 34Access Control 6,43Access Door Control 10ADEMCO 4+2 EXPRESS60ADEMCOCONTACTID60Ademco Contact ID reporting 39ADEMCO HIGH SPEED60Ademca Low Speed 49,60Alarm Sounder Duration9Alpha Descriptors 7AMSECO motor bell& box 32Amseco PAL 328N 25Arm-Away 12Arm-Stay 12Arming Away 42Arming Functions 42Arming Instant 42Arming Maximum42Arming Stay 42ATLIS-BBS 2Auto-arm 10AUXILIARYDEVICECURRENTDRAWWORKSHEET35

BB401 B 13BACK-UP BAITERY 60Back-Up Power 34BAITERY STANDBY 34Built-in Users Manual 6Bypass 9Bypassing Zones 42

cCabinet 6Callback 7CANADIANDEPARTMENTOFCOMMUNICATIONS55Cancel Repotl 7CD 45Check Messages 44checksum 50Chime Mode 9,42Circuit Breakers 6CIRCUITPROTECTORS60CLOCK, RealTime

Setting the 36Cold Water Pipe 34Comm. Defaults 7COMM. FAILURE52Comm. Fields 7

Communication 5Confirmation of Arming Ding 9CONSOLES

Maximumwire length 31Powering Additional 31Programming31Remote 30

CONTACTIDEVENT CODESTable of 51

Contact ID Reporting 51ADVISORY 51

CTS45Custom Words 7

DDaylight Savings Time 10DB2545Delay Closing Time 43Descriptors 6DH400 base 13DIGITALCOMMUNICATOR60DIP SWITCHTABLES 56DIP switches 18Disarm 12Disarming42Downloaded Messages

Viiwing 43Downloading7

Direct Wire 48DSR45DTMF50DTR45Dual reporting 49Dual Tone Multi-Frequency 50Duress 9,37

EE818Earth Ground Connections 34EDP printer 45EEROM5End User Scheduling 10Entry and Exit Delays 9Entry/Exit 11, 1, 2EOL 24EOLR 13EOLR Fire Zone 13EOLR Supervised 13, 14ESL 21Event Log

Clearing 47Event Logging 6

Display & Print Modes 46Printer Connections 45

Event Programming 10Exception Reporting 7Exit Delay 9expanded reporting 49

FFCC54FCC REGISTRATIONNO 60form C 26

GGlass Break Detector 6Glass Break Deteotors 14Glass Break Devices 14Global Arm 42

Page 65: ADEMCO manual 4140

Global Arming 6,42Global Arming Notes 42Global Disarm 42GoT09Go/No Go19Go/No Go Mode 18GOTO 8,43GOTO Function 39Ground Stari 23Ground Start Module 23

HHARD-WIREDZONES 13High Speed Reporting 50

Lirnitation550 -house ID 17, 18

IIEI 735L 14Installer 37Installer Code 7Intercom Interference 15Interference Handbook 54Interior w/Delay 12Interior, Follower 11

:745J845

KKeyswitch 24kiss-off 49

LLevel 037Level 137Level 238Levels 3-538LIMITEDWARRANTY 63LINE SEIZE 60Lock, Cabinet

Mounting the 33LORRA7LORRA Subscriber Radios 23

MManager37,40Master 37,40Master Codes 39Max. Zone Resistance 14modem48MULTIPLEPARTITIONACCESS 39

NNot Ready 42NP4-12 34,60NP7-12 34,60

0Open/close 9, 49Open/close by exception 10Operator 38Operator code 40Operator level A 37Operator level B 37Operator level C 37Output Control 5,26

P

PA40032PA400B 32PA400R 32PABX 32Panic Keys 5,9, 12PART 6854PariitionSpecificFeatures9PartitioningFeatures

BASIC8PCBoard

Mountingthe33PerimeterBurglary.11PhoneLineConnections32PhoneNumbers7PollingLoop6, 15

Extending16POLLINGLOOPADVISORIES15POLLINGLOOPCURRENTDRAWWORKSHEET35PollingLoopExtender16Power-UpProcedure34PrimatySubscriberNumber9Programming5

QQuickArm9,42Quick Bypass6

RRADIONICSLOW SPEED 60Real-TimeClock 7

Setting the 36Relay Control 10relay modules 10RELAYS

Examples of Users 27Remote Sounder 25Resistance 13Response Time 13, 14RF Receivers 17RINGER EQUIVALENCE60ringer equivalence number 54RJ31X54RPM 15RS23245

sScheduling 6, 10Scheduling Menus 7Secondary Subscriber 9Serial numbers 18SESCC)A60SescowFiadionics 49SET-UPERROR18Smoke Detectors 13, 14Sniffer Mode 17SOUNDERS

Compatible32External 32

Spatial Diversity 16SPECIFICATIONS60Split reporting 49Split/Dual Reporting 7,49STANDBY CURRENT DRAW 34SUMMARY OF CONNECTIONS 61Supervised Fire 12Swinger Suppression 9SYSTEM FEATURES

SUMMARY 5System Sensor 21

System Sensor 140013System Sensor 145113System Sensor 1451DH 13System Sensor 2300T 13System Sensor 240013System Sensor 2400TH 13System Sensor 245113System Sensor 2451TH 13

TTECHNICALSUPPORT

CONTACT2test 49Test Mode 52Test Reporting 7time windows 10TouchTone 50Transmitter ID 18Transmitters 19Trouble by Day/Alarm by Night 11Trouble Conditions 44

uUL INSTALLATIONREQUIREMENTS54UL installations 13UL NOTE7UL102360UL60960Unsupervised 13, 14User Codes 5,7,9,37,38

Adding a Master ManagerorOperator 40Changeing a Master Manager orOperator 40Deleting a Master ManagerorOperator 40General Information 37

User’s ManualUsing the Built-In 43

vVoltage Triggers 7,23

wWireless 6

Advisories 20

xX-10 5, 10,26

zZone 113Zone 1 Advisories 13Zone 913Zone 9 Advisories 13ZONE CONFIGURATION 11Zone Reports 7Zones 2-814Zones 2-8 Advisories 14

-65-

Page 66: ADEMCO manual 4140
Page 67: ADEMCO manual 4140

-67-

Page 68: ADEMCO manual 4140

..

“ADEMCO, ALARM DEVICE MANUFACTURING CO.A DMSIONOFPIT’IWAYCORP.

165 EILEENWAY, SYOSSET, NY 11791

4140XMPT2-INST Y93 (pat of N5944-2) COPYRIGHT@ 1993 PMWAY CORPORATION