Click here to load reader
Upload
bilal-hamad
View
668
Download
29
Tags:
Embed Size (px)
Citation preview
EU-CA091
LG Electronics Air Conditioning Marketing
20 Yoido-dong, Youngdungpo-gu, Yoido P.O.Box 355 Seoul 150-721, KoreaPhone: 82-2-3777-7985 Fax: 82-2-3777-5136http://www.lge.com
For continual product development, LG
reserves the right to change specifications without notice.
© LG
Electronics Inc. Printed in Korea January 2009
LG Commercial Air Conditioners 2009Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG
ww
w.l
ge
air
co
n.c
om
“ E c o - D e s i g n , E n e r g y E f f i c i e n t ,R e d u c e C O 2 E m i s s i o n s ”
En joy C lean , Quiet , and Comfortab le
A i r Condit ion ing with LG
LG Air Conditioners are environment-friendly & future-oriented. To reduce freon gas, a prime ozone destroyer, they adopt alternative refrigerant R-410A, and neo
plasma air-purifying system for powerful sterilization for health-conscious customers. Also, ARTCOOL
series with outstanding designs have received International Forum Design Award, Reddot Design Award
and G Mark. They have improved air flow innovatively to realize world’s lowest noise, and provide a
more pleasant and convenient indoor environment.
Environmental concern 2009As the concern for environment increases day by day, EC Directive made it a regulation to put an
indication on all air conditioning products. With the information regarding energy-saving, customers
will easily understand products considering the environment.
Customers will have to purchase the products considering the energy label to meet their needs. Energy
label shows the energy consumption of the unit classified with 7 different colors..
Energy Efficiency Class of The Unit In Cooling Mode :
Energy Efficiency Class of The Unit In Heating Mode :
LG Air Conditioners 2009 0302
With the advancement of inverter technology comes more silent, economical and powerful airconditioning systems.
DC Inverter Technology
En joy C lean , Quiet , and Comfortab le A i r Condit ion ing with LG
Step-up Inverter by the PFC & the Sine Wave Control Technology (PFC : Power Factor Correction)The LG air conditioner is manufactured using the PFC and the sine wave technology. By the PFC contorl,raising the operating voltage from the existing DC 280V to DC 380V can be done. Thereby, it makes theoperation smooth in a high-frequency area. The sine wave control enables soft operation in a low frequencyarea, thereby expanding the product's operating range. This also markedly improves the product's energy efficiency.
Powerful BLDC CompressorThe LG inverter air conditioner comes with a BLDC compressorthat uses a strong neodymium magnet. Its compressor thus hasimproved efficiency compared with AC inverter. Notably,during partial-load operation (30-45 Hz), the efficiency of thecompressor motor of the LG inverter air conditioner increases,as opposed to the existing AC motors, and the subcoolingeffects of the bigger condensor will further increase theproduct's energy consumption efficiency.
LG Air Conditioners 2009 0908
Loss Full range
• Sine wave Control in BLDC Compressor
Sine waveRectangle wave
DC280V
VI
Partial switching
V
I
Full range Sine wave switching
DC 380V(Boost up)
• PFC Control in Power Input
BLDC FanBLDC fan motor offers additional energy saving in operatingmode. Compared with AC motors, BLDC fan motor can cutenergy by 35% at full velocity. AC motor is operating at fullvelocity only, but BLDC Motor can change velocity accordingto load. Energy efficiency levels at low velocities in particularhave been improved by 65%.
65%EnergySaving
Portial Load Full Load
35%Mot
or In
put
AC Fan MotorDC Fan Motor
Load
Stator Rotor
90Hz
Rectangle wave Sine wave
110Hz
U n i q u e F e a t u r e s
Top Class COP• DC Inverter Compressor• BLDC Fan Motor
Comfortable with Fast Cooling & Heating PerformanceWhen the air conditioner is initially activated to either heat or cool, the compressor will operate atmaximum speed to reach the desired temperature quickly. Once the desired temperature is achieved,unlike conventional air conditioners that turn the compressor on and off, LG inverter units constantlyadjust and vary the compressor speed to maintain the desired temperature with minimal fluctuation toensure that your comfort is not compromised.
Wide Operating RangeWhen cooling computer rooms and other rooms in the event of lowoutdoor temperatures, the BLDC inverter compressor and outdoorBLDC fan motor are used to adjust the air flow and volume, with a viewto ensuring efficient operation by allowing the air conditioner to keepoperating at -10°C without turning it off.
*Testing Combinations
2.5kW 3.5kW 5.0kW
COP
3.33
3.70
3.21 3.21
3.643.62
HeatingCooling
INDOOR
OUTDOOR
UT09
UU09W
UT21
UU21W
UT18
UU18W
Capacity 2.5kW 3.5kW 5.0kW
Temp
Time
Setting Temp.
Power
On On OnOff Off Off
Temp
Time
Setting Temp.
Power
INVERTERConventional
Indo
or T
emp(
˚C)
Outdoor Temp(˚C)
10
18
30
32
-15
21
-10 21 35 43
Cooling
Heating
Low AmbientControl
Slim & Compact SizeEasy & efficient installation of outdoor unit will provide the best solution for small offices and shops.
Easy to ServiceEasy & efficient installation of outdoor unit will provide the best solution for small offices and shops.
54%Reduction
46%Reduction
• Foot Print Area (Top View) • Volume
806x1057x690mm 950x1380x330mm
3 pieces
of screw
Ez SVC
4 way1 way
1. Inner SVC valve- 4 Way piping is possible
(Front, Rear, Right, Down)- Excellent exterior
2. Convenient moving handle- Fitted hand grips for easy
transportation and installation
3. Compact Design & Ez SVC- Remove 3 pieces of screw for SVC- Front panel removal system
Inve
rter
Tec
hnol
ogy
Synchro
LG Air Conditioners 2009 4140
It offers very useful solution to customer with reasonable prices. It uses 2,3 or 4indoor units with one outdoor unit. Each indoor units are running as one cyclewith same mode(cooling or heating). It helps same air distribution all arround themiddle or larger room(office or open places) even in irregualr shaped spaces.The total capacity based on outdoor unit for Synchro operation are the same asfor the fixed combinations.
Synchro operation
Sync
hro
• Simultaneously On/Off (1 Cycle)
• Connectable up to 4 indoor units
• Only using simple branch piping
• DC Inverter : 12.5/14.0/15.0 kW
• 3Phase DC Inverter : 12.5/14.0/15.0 kW
• High Efficiency & Low Noise
• Choice of various indoor type
2 branch
PMUB11A PMUB111A PMUB1111A
3 branch 4 branch
3PHASE DC INVERTERLG Air Conditioners 2009DC INVERTERLG Air Conditioners 2009 42
Outdoor Unit
Indoor Unit
UU42W / UU48W / UU60W
Synchro Outdoor
Note : Due to our policy of innovation some specifications may be changed without notification.
Nominal Capacity Cooling kW (Min~Rated~Max) Heating Btu/h Norminal Input Cooling kW (Min~Rated~Max) Heating kW Running Current Cooling/Heating A Power supply ø,V,Hz Dimensions W*H*D mm(inch) Net Weight Outdoor kg(lbs) Refrigerant Charge* g(oz) Air Circulation CMM(CFM) Noise Level(H/L) Sound Press,1m dB(A)±3 SVC Valve Liquid mm (inch) Gas mm (inch) Max. Interunit Total Piping(Main+Total Branch) m Piping Length Main Piping m
Total Branch Piping m Each Branch Piping m
Max. Installation Indoor Unit~Outdoor Unit m Height Difference Indoor Unit~Indoor Unit m
UU42W U3D
"Synchro application
(simultaneous operation).
Refer to combination table. "
17.7/16.7
1, 220~240, 50
950*1380*330 (37.4*54.3*13.0)
103(227)
3600(127)
55(1942) X 2
55/51
9.52 (3/8)
15.88 (5/8)
80
40
40
10
30
1
UU48W U3D
"Synchro application
(simultaneous operation).
Refer to combination table. "
20.5/20.5
1, 220~240, 50
950*1380*330 (37.4*54.3*13.0)
103(227)
3600(127)
55(1942) X 2
55/51
9.52 (3/8)
15.88 (5/8)
80
40
40
10
30
1
UU60W U3D
"Synchro application
(simultaneous operation).
Refer to combination table. "
24.7/23.5
1, 220~240, 50
950*1380*330 (37.4*54.3*13.0)
103(227)
3600(127)
55(1942) X 2
55/51
9.52 (3/8)
15.88 (5/8)
80
40
40
10
30
1
Nominal Capacity Cooling Btu/h(Min~Rating~Max) W
Heating Btu/hrW
Nominal Input Cooling W(Min~Rating~Max) Heating WE.E.R W/WC.O.P W/WOperational Temperature Cooling °CRange(Outdoor) Heating °C
UT12/UT18/UV18/UB18 N*CUT24/UT30/UV24/UV30/UB24/UB30 N*D
Synchro application
(simultaneous operation).
Refer to each indoor unit specification
-10 ~ 43
-15 ~ 24
43
Outdoor Unit
Indoor Unit
UU43W / UU49W / UU61W
Synchro Outdoor
Sync
hro
Note : Due to our policy of innovation some specifications may be changed without notification.
Nominal Capacity Cooling kW (Min~Rated~Max) Heating Btu/h Norminal Input Cooling kW (Min~Rated~Max) Heating kW Running Current Cooling/Heating A Power supply ø,V,Hz Dimensions W*H*D mm(inch) Net Weight Outdoor kg(lbs) Refrigerant Charge* g(oz) Air Circulation CMM(CFM) Noise Level(H/L) Sound Press,1m dB(A)±3 SVC Valve Liquid mm (inch) Gas mm (inch) Max. Interunit Total Piping(Main+Total Branch) m Piping Length Main Piping m
Total Branch Piping m Each Branch Piping m
Max. Installation Indoor Unit~Outdoor Unit m Height Difference Indoor Unit~Indoor Unit m
UU43W U3D
"Synchro application
(simultaneous operation).
Refer to combination table. "
4.09/4.28
3 ,380~415 , 50
"950*1380*330 (37.4*54.3*13.0)"
103(227)
3600(127)
55(1942) X 2
55/51
9.52 (3/8)
15.88 (5/8)
80
40
40
10
30
1
UU49W U3D
"Synchro application
(simultaneous operation).
Refer to combination table. "
4.98/5.23
3 ,380~415 , 50
"950*1380*330(37.4*54.3*13.0)"
103(227)
3600(127)
55(1942) X 2
55/51
9.52 (3/8)
15.88 (5/8)
80
40
40
10
30
1
UU61W U3D
"Synchro application
(simultaneous operation).
Refer to combination table. "
5.91/5.79
3 ,380~415 , 50
"950*1380*330 (37.4*54.3*13.0)"
103(227)
3600(127)
55(1942) X 2
55/51
9.52 (3/8)
15.88 (5/8)
80
40
40
10
30
1
Nominal Capacity Cooling Btu/h(Min~Rating~Max) W
Heating Btu/hrW
Nominal Input Cooling W(Min~Rating~Max) Heating WE.E.R W/WC.O.P W/WOperational Temperature Cooling °CRange(Outdoor) Heating °C
UT12/UT18/UV18/UB18 N*CUT24/UT30/UV24/UV30/UB24/UB30 N*D
Synchro application
(simultaneous operation).
Refer to each indoor unit specification
-10~43
-15~24
LG Air Conditioners 2009 44
Combination Table
Synchro
UU42W U3D
UU43W U3D
UU48W U3D
UU49W U3D
UU60W U3D
UU61W U3D
AppliedAccessiries
OUTDOORUNITS
* When install ceiling and floor type synchro combinations, You must use wired remote controller “ PVRCUSZ0“ * In case of cassette or duct type synchro combinations, You can use only one wired remote controller included in the indoor units.** When using synchro operation,
- Do not use wireless remote controller. - Use only one wired remote controller in the indoor units.- Use central controller and function controller “PQCSB101S0 & PQCSC101S0” only.
Possible combination of indor units
Installation scene
Cassette Duct Ceiling & Floor
PVRCUSZ0 PVRCUSZ0
PMUB11A
PQCSB101S0
PQCSC101S0
PMUB111A PMUB1111ABD unit
Functioncontroller**
Wired remotecontroller*
Simple centralcontroller**
Cassette Duct Ceiling & Floor Cassette Duct Ceiling & Floor
Duo Trio Quartet
ODU
BD
ODU
Capacity (kW)Cooling Heating
12.5 14.0
14.0 16.0
15.0 17.0
UT24 NPD *2
UT24 NPD *2
UT30 NPD *2
UB24 NHD *2
UB24 NHD *2
UB30 NGD *2
UV24 NBD *2
UV24 NBD *2
UV30 NBD *2
UT18 NQD *3
UT18 NQD *3
UT18 NQD *3
UB18 NHD *3
UB18 NHD *3
UB18 NHD *3
UV18 NBD *3
UV18 NBD *3
UV18 NBD *3
UT12 NRD *4
UT12 NRD *4
UT12 NRD *4
-
-
-
-
-
-
BD BD
IDU IDU IDU IDU IDU IDU IDU IDU IDU
ODUIDU : INDOOR UNITODU : OUT DOOR INUTBD : BRANCH DISTRIBUTOR UNITREMO : WIRED REMOTE CONTROLLER
REMO REMO REMO
PMUB11A
PMUB111A
PMUB1111A
2 units
3 units
4 units
50:50 (1:1)
33:33:33 (1:1:1)
25:25:25:25 (1:1:1:1)
Model Indoor Indoor Capacity Ratio(%)
Branch Pipe
Installation Information
Model Indoor
Model Outdoor
Liquid
Gas
1. Piping Connections
Cassette
Duct
Ceiling & Floor
1ø Inverter
3ø Inverter
øInch [mm]
øInch [mm]
UT12 NRD
-
-
-
-
1/4 (6.35)
3/8 (9.52)
UT18 NQD
UB18 NHD
UV18 NBD
-
-
1/4 (6.35)
1/2 (12.7)
UT24 NPD
UB24 NHD
UV24 NBD
-
-
3/8 (9.52)
5/8 (15.88)
UT30 NPD
UB30 NGD
UV30 NBD
-
-
3/8 (9.52)
5/8 (15.88)
-
-
-
UU42W U3D
UU43W U3D
3/8 (9.52)
5/8 (15.88)
-
-
-
UU48W U3D
UU49W U3D
3/8 (9.52)
5/8 (15.88)
-
-
-
UU60W U3D
UU61W U3D
3/8 (9.52)
5/8 (15.88)
2. Power Supply
Model Outdoor
Power Supply
1ø Inverter
ø, Voltage
UU42W U3D
1, 220~240
Model Outdoor
Power Supply
3ø Inverter
ø, Voltage
UU43W U3D
3, 380~415
UU48W U3D
1, 220~240
UU49W U3D
3, 380~415
UU60W U3D
1, 220~240
UU61W U3D
3, 380~415
UU30
1,220~240
UU30W
1,220~240
UU37
3,380~415
UU36W
1,220~240
UU48
3,380~415
UU48W
1,220~240
UU60
3,380~415
UU60W
1,220~240
3. Additional Refrigerant Charge
Model Outdoor
Refrigerant Charge (g/m)
1ø Inverter UU42W U3D
40
Model Outdoor
Refrigerant Charge (g/m)
3ø Inverter UU43W U3D
40
UU48W U3D
40
UU49W U3D
40
UU60W U3D
40
UU61W U3D
40
UU30
35
UU30W
35
UU37
40
UU36W
35
UU48
40
UU48W
50
UU60
50
UU60W
50
4. Drain Pipe
Model Indoor
Drain Pipe (*OD/ID)
Cassette UT12 NRD
32/25
Model Indoor
Drain Pipe (OD/ID)
Model Indoor
Drain Pipe (OD/ID)
Duct
Ceiling & Floor
UT18 NQD
32/25
UB18 NHD
32/25-
UT24 NPD
32/25
UB24 NHD
32/25
UT30 NPD
32/25
UB30 NGD
32/25
UT36
32/25
UB36
32/25
UT48
32/25
UB48
32/25
UT60
32/25
UB60
32/25
-
UV18 NBD
26/20
UV24 NBD
26/20
UV30 NBD
26/20
*OD: Out Diameter / ID: In Diameter
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27oC DB /19oC WB- Outdoor Temperature 35oC DB / 24oC WB
Heating: - Indoor Temperature 20oC DB / 15oC WB- Outdoor Temperature 7oC DB / 6oC WB
- Level Difference Within Zero.
- No optional accessories (i.e. Plasma kit, elevation grille etc.)
- With maximum air volume.
Note :Due to our policy of innovation some specifications may be changed without notification.
Measurement Conditions
45
Sync
hro