Upload
others
View
63
Download
2
Embed Size (px)
Citation preview
UPDN
C6C7FC1
FC2
FC3
C10 C12
C13
C19
C22
C14
C26C23 C24
C15
C21
C25
C20
FC4
FC5
B1
B2 B2 B2 B2
B3
B4B5 B6 B7
B8 B9 B10 B11 B12
B14 B15B13
B17
B19
B20
B21 B22 B23
B25
B26
B27
B28
B29
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B47
B48
B48
A/M
BK
TB
49
MB
KT
3
MB
MB1B
A1
E1
FC4
FC5
ISMB 600
ISMB 600
ISMB 600
ISMB 600
ISMB 600
ISMB 600
ISM
B 6
00
ISM
B 6
00
ISM
B 6
00
ISM
B 6
00
ISMB 600
ISMB 600
ISM
B 6
00
F
ISMB 600
B50
B51
B52
B53
B2A
FC2
FC1
B2(600X230) S1
SECTION A1-A1
B5(600X650)
S1
ISMB 600
PROJECT STAGE :
TENDER DRAWING
ADC-123-117-R01
STRUCTURAL CONSULTANT
CLIENT:
JOB NO. SCALE DATE DWN.BY CHK.BY
AS SHOWN
@A1
DRAWING TITLE :
R.C.C DETAILS OF TERRACE FLOOR PLAN
PROJECT :
PROPOSED ANNEX BUILDING AT PLOT NO.89, 89A,SIR POCHKHWANWALA
ROAD,WORLI,MUMBAI
NOTES:
1.THIS DRAWING IS THE PROPERTY OF ASSOCIATED CONSULTANTS
& CANNOT BE USED WITHOUT THEIR WRITTEN PERMISSION.
2.DRAWING SHALL NOT BE SCALED WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3.THIS DRAWING TO BE READ ALONG WITH OTHER RELEVANT DRAWINGS.
4.ANY VARIATION BETWEEN THE DRAWING & THE SPECIFICATION, SHOULD BE BROUGHT
TO THE NOTICE OF THE ARCHITECTS BY THE CONTRACTORS IN WRITTING PRIOR TO
CONSTRUCTION.
DWN. CHKD. APPD.DATEREV.
ADC-123 30.06.15 TPS USJ
DESCRIPTION
REFERENCE DRAWINGS
DRG.NO. DRAWING TITLE
MAHARASHTRA STATE POLICE HOUSING &
WELFARE CORPORATION LTD
R.C.C DETAILS OF TERRACE FLOOR PLAN(SHEET 1
2)ADC-123-117-R00
R00.
ASSOCIATED CONSULTANTS
CONSULTING ENGINEERS
A-801, SAI TIRTH, SIDDHARTH
NAGAR, KOPRI,
THANE (E),400603.
TEL- 25327085,25325604,
# FAX 25361721
9. All buildings shall have tie beams/plinth beams at ground/plinth level.
75I
NOTES:
4. Clear covers
2. Due care shall be taken to ascertain that requisite strength of concrete is gained
1. Basic referance code:- IS 456: 2000, IS 1893, IS 13920
12. Fire rating considered:- 2 Hour Max.
40
75
20
25
9. Design is valid for number of floors as indicated in the drawing.
8. If footings overlap each other, necessary revision shall be obtained from our office.
10. At any level where column size gets reduced in either dimension tie beams/plinth beams are essential.
11. For cantilevers, top bars to be anchored behind from external face of support for -1.5 X span of cantilever.
II
VI
SlabsIV
V
Columns & walls >200mm width
Pile cap
Beams
5. Beams having depth more than 750mm, provide side-face reinforcement.
Footings
6. Substratum shall be approved from our office before laying P.C.C.
7. Minimum clear spacing between any two longitudinal bars in beam= 50mm.
8. All laps (Ld) shall be staggered & not more than 50% bars to be lapped
any injury to any personnel arising out of any accidents.
Accidents occurring due to premature deshuttering, faulty / substandard construction material or
Correctness/safety of any temporary structure, scaffolding, shuttering, centering erected at site and
Safety of construction worker/any personnel at work site during construction
1. Our responsibility shall remain limited to safe and sound structural design as transmitted
Safety of old structure during demolition.
Safety of any adjoining building /persons staying in adjoining building/persons
c)
d)
e)
a)
b)
3. All structural concrete should be weigh batched, machine mixed & mechanically vibrated.
Any accident occurring due to construction of elements of buildings not designed by us.
2. Supervision if specifically asked for will be provided to the extent of verification of reinforcement on site
f)
Use of this drawing for construction shall explicitly confirm acceptance of following conditions
25III Columns & walls having width of 200mm & below
4. Any discrepancy between our drawing & Architects' drawing shall be brought to our notice before construction.
5. This drawing is property of ASSOCIATED CONSULTANTS and shall not be reproduced or used
at any given section. Ld = 50 X D (where D= dia. of Bar)
before commencement of deshuttering. It shall comply with provisions of Clause No. 11.3 of IS 456: 2000.
by Owner / Builder / Contractor
by this drawing and we shall not remain responsible for
and properties on adjoining roads.
workmanship / faulty construction procedure.
but responsibility regarding correct & sound construction shall solely rest with contractor/ builder / owner.
without explicit permission of this office.
3. Earthquake zone considered is zone III for Mumbai region.
304,Sent inel,Hiranandani Business Park,
Powai,Mumbai - 400 076,Maharashtra,India.
T: +91 22 6691 9400 F: +91 22 6692 4077
w w w . s a n k a l p a n . c o m
3-T16
(BOTT.BAR)
3-T16
(TOP BAR)
2-T12 S.F.R.(EACH FACE)
2LT10@150
ISMB 600
3-T16
(BOTT.BAR)
3-T16
(TOP BAR)
2-T12 S.F.R.(EACH FACE)
2LT10@150
DETAIL ADETAIL B
ISM
B 6
00
ISMB 600
4-T16
2LT8@200
DETAIL C
B31(600X650)
SECTION E1-E1
S4
B22(600X650)
SECTION E1-E1
S4
C1
S1A
SECTION C1-C1
S1A
1. FILLING WORK AT ANY RAISED OR SUNK PORTION SHOULD BE STRICTLY IN
LIGHT WEIGHT BRICKS ONLY.
S5
TPS USJ30.06.15ISSUED FOR TENDER USJ
R01. TPS USJ19.08.15REVISED P.T. BEAM DETAILS USJ
BEAM SCHEDULE (M40:Fe500) (LEVEL:TERRACE)
REMARKSSHEAR STIRRUPS
STRAIGHT EXTRA
LEFT SUPP
EXTRA
RIGHT SUPP
TOP REINFORCEMENT
STRAIGHT CURTAILED
BOTTOM REINFORCEMENT
BD
SIZE
NUMBERS
BEAM
B1 230600
-
3-T12
T8@150
2-T12
- -
CANTILEVER
B2, 2A*
B3
230600
230600
600600
600600
230600
650600
230600
2-T16
2-T12
-
-
5-T25
5-T25
2-T16+
2-T12
5-T25
3-T20
-
-
-
-
-
2-T12
3-T12
2-T16+
2-T12
3-T25
4-T25
3-T20
3-T20
T8@150
- -
1-T12 1-T12
T8@200
T8@150
- -
-
2-T20+
5-T16
4LT8@2004LT8@200
4LT8@200
2-T20+
5-T16
-
2-T25 -
4LT8@200
- - 2LT10@100
CANTILEVER
B28
B29
B30
B31
B32,40
B33,41
B34,42
B35,43
B44
B45
B46
B47
B48,48A
B49
600 650
600 650
600 300
600 150
600 230
600 230
600 230~650
600 650
600 650
600 650
600 600
600 600
600 600
600 600
600 650
600 650
600 650
600 150
600 230
600 230
-
-
-
-
2-T12
3-T16
2-T12
3-T25
3-T25
3-T20
5-T20
5-T20
5-T20
3-T20
5-T25
5-T25
5-T20
3-T20
5-T25
5-T25
3-T20
2-T12
3-T12
4-T20
3-T20
3-T20
-
2-T25
-
-
-
-
-
-
-
-
-
-
-
-
3-T25
3-T25
3-T25
2-T10
2-T12
3-T20
3-T25
3-T25
3-T25
3-T25
3-T25
3-T25
3-T25
3-T25
3-T25
3-T25
3-T25
2-T25
4-T16
2-T10
-
-
-
-
-
-
2-T25 2-T25
2-T25+
3-T25
2-T25
2-T25+
3-T25
-
2-T20
2-T20 2-T20
-
2-T25+
3-T25
2-T20
-
2-T25+
3-T25
2-T25+
5-T25
2-T25+
3-T20
2-T25+
3-T20
2-T25+
3-T20
- -
- -
- 1-T12
-
2-T25+
2-T25
2-T25+
2-T25
2-T25
2-T25 2-T20
2-T20 2-T20
T8@100
T10@100
T8@200
4LT8@150
4LT8@150
3LT8@100
T8@200
T8@200
T10@125
4LT8@200
4LT8@200
4LT8@200
4LT8@200
4LT8@200
4LT8@200
4LT8@200
4LT8@200
4LT8@200
4LT8@200
4LT8@200
CANTILEVER
CANTILEVER(INVERETED)
CANTILEVER
CANTILEVER
MB 230750
2-T16 2-T16
- - 2L-T8@200-
MB1 230300
2-T16
1-T12
+ -
2-T16
1-T12
+ - - 2L-T8@150
MIDLANDING BEAM(INVERTED)
B5 600 650
B6
B4
600 650
4-T32
4-T32
3-T32
3-T32
3-T25
3-T25
2-T25+
3-T32
2-T25+
5-T25
4LT10@150
4LT10@150
2-T25+
5-T25
2-T25+
3-T32
B8
B9
B10
B11
6006005-T25
-3-T20
- -
4LT8@200
B12
B13,19
B14
B15
B17
B21
B22
B23
B25
B26
B20
B27
B36
B37
B38
B39
600 650
600 650
600 650
600 650
3-T20
6-T32
6-T32
6-T32
-
-
-
-
4-T32
4-T32
4-T32
4-T32
2-T32+
6-T32
4LT10@150
-
2-T32+
6-T32
-
4LT12@125
- -
4LT10@150
2-T32+
6-T32
-
4LT12@150
2306002-T12
-
3-T12
T8@150
- -
CANTILEVER
B7
CANTILEVER
MBKT 230300
- -- - 2L-T8@125-
MIDLANDING BEAM (CANTILEVER)
INVERTED
B50*,51*,52,53
-
-
-
-
-
-
-
- -
MBKT 600 230
-
3-T16 4-T16
- -
T10@100 CANTILEVER(INVERETED)
2-T16
1-T12
+
2-T16
1-T12
+
600 650
600600
600600
PROJECT STAGE :
TENDER DRAWING
ADC-123-118-R01
STRUCTURAL CONSULTANT
CLIENT:
JOB NO. SCALE DATE DWN.BY CHK.BY
AS SHOWN
@A1
DRAWING TITLE :
R.C.C DETAILS OF TERRACE FLOOR PLAN(SHEET 2/2)
PROJECT :
PROPOSED ANNEX BUILDING AT PLOT NO.89, 89A,SIR POCHKHWANWALA
ROAD,WORLI,MUMBAI
NOTES:
1.THIS DRAWING IS THE PROPERTY OF ASSOCIATED CONSULTANTS
& CANNOT BE USED WITHOUT THEIR WRITTEN PERMISSION.
2.DRAWING SHALL NOT BE SCALED WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3.THIS DRAWING TO BE READ ALONG WITH OTHER RELEVANT DRAWINGS.
4.ANY VARIATION BETWEEN THE DRAWING & THE SPECIFICATION, SHOULD BE BROUGHT
TO THE NOTICE OF THE ARCHITECTS BY THE CONTRACTORS IN WRITTING PRIOR TO
CONSTRUCTION.
DWN. CHKD. APPD.DATEREV.
ADC-123 30.06.15 TPS USJ
DESCRIPTION
REFERENCE DRAWINGS
DRG.NO. DRAWING TITLE
MAHARASHTRA STATE POLICE HOUSING &
WELFARE CORPORATION LTD
R.C.C DETAILS OF TERRACE FLOOR PLAN(SHEET 2
2)ADC-123-118-R00
R00.
ASSOCIATED CONSULTANTS
CONSULTING ENGINEERS
A-801, SAI TIRTH, SIDDHARTH
NAGAR, KOPRI,
THANE (E),400603.
TEL- 25327085,25325604,
# FAX 25361721
9. All buildings shall have tie beams/plinth beams at ground/plinth level.
75I
NOTES:
4. Clear covers
2. Due care shall be taken to ascertain that requisite strength of concrete is gained
1. Basic referance code:- IS 456: 2000, IS 1893, IS 13920
12. Fire rating considered:- 2 Hour Max.
40
75
20
25
9. Design is valid for number of floors as indicated in the drawing.
8. If footings overlap each other, necessary revision shall be obtained from our office.
10. At any level where column size gets reduced in either dimension tie beams/plinth beams are essential.
11. For cantilevers, top bars to be anchored behind from external face of support for -1.5 X span of cantilever.
II
VI
SlabsIV
V
Columns & walls >200mm width
Pile cap
Beams
5. Beams having depth more than 750mm, provide side-face reinforcement.
Footings
6. Substratum shall be approved from our office before laying P.C.C.
7. Minimum clear spacing between any two longitudinal bars in beam= 50mm.
8. All laps (Ld) shall be staggered & not more than 50% bars to be lapped
any injury to any personnel arising out of any accidents.
Accidents occurring due to premature deshuttering, faulty / substandard construction material or
Correctness/safety of any temporary structure, scaffolding, shuttering, centering erected at site and
Safety of construction worker/any personnel at work site during construction
1. Our responsibility shall remain limited to safe and sound structural design as transmitted
Safety of old structure during demolition.
Safety of any adjoining building /persons staying in adjoining building/persons
c)
d)
e)
a)
b)
3. All structural concrete should be weigh batched, machine mixed & mechanically vibrated.
Any accident occurring due to construction of elements of buildings not designed by us.
2. Supervision if specifically asked for will be provided to the extent of verification of reinforcement on site
f)
Use of this drawing for construction shall explicitly confirm acceptance of following conditions
25III Columns & walls having width of 200mm & below
4. Any discrepancy between our drawing & Architects' drawing shall be brought to our notice before construction.
5. This drawing is property of ASSOCIATED CONSULTANTS and shall not be reproduced or used
at any given section. Ld = 50 X D (where D= dia. of Bar)
before commencement of deshuttering. It shall comply with provisions of Clause No. 11.3 of IS 456: 2000.
by Owner / Builder / Contractor
by this drawing and we shall not remain responsible for
and properties on adjoining roads.
workmanship / faulty construction procedure.
but responsibility regarding correct & sound construction shall solely rest with contractor/ builder / owner.
without explicit permission of this office.
3. Earthquake zone considered is zone III for Mumbai region.
304,Sent inel,Hiranandani Business Park,
Powai,Mumbai - 400 076,Maharashtra,India.
T: +91 22 6691 9400 F: +91 22 6692 4077
w w w . s a n k a l p a n . c o m
SIZE- 450X450
STEEL- 8-T12
LINK-T8@150C/C
FC FROM TERRACE LVL.UPTOOHT LVL. TO BE TAKEN FROM
PT BEAM
* PARTLY INVERTED
5-T25
3-T20
4LT8@200
5-T25
3-T20
4LT8@200
PARTLY INVERTED
PARTLY INVERTED
* INVERTED
MIDLANDING BEAM(INVERTED)
-
4-T32 -
3-T25
4LT10@150
2-T25 2-T25
PARTLY INVERTED
SUNK
1. FILLING WORK AT ANY RAISED OR SUNK PORTION SHOULD BE STRICTLY IN
LIGHT WEIGHT BRICKS ONLY.
B45
(600X650)
5-T25
3-T20
B12
(600X600)
TPS USJ30.06.15ISSUED FOR TENDER USJ
P.T. BEAM (REFER P.T. DRG FOR P.T. BEAM)
P.T. BEAM (REFER P.T. DRG FOR P.T. BEAM)
P.T. BEAM (REFER P.T. DRG FOR P.T. BEAM)
R01. TPS USJ19.08.15REVISED P.T. BEAM DETAILS USJ
BEAM SCHEDULE (M40:Fe500)
REMARKS
SHEAR
STRAIGHT EXTRA
LEFT SUPP
EXTRA
RIGHT SUPP
TOP REINFORCEMENT
STRAIGHT CURTAILED
BOTTOM REINFORCEMENT
BD
SIZE
NUMBERS
BEAM
WB1,4 2301850
-
4-T164-T20
- -
WB5,6 23018504-T20 4-T16
-
-
STIRRUPS
- -
PROJECT STAGE :
TENDER DRAWING
ADC-123-119-R00
STRUCTURAL CONSULTANT
CLIENT:
JOB NO. SCALE DATE DWN.BY CHK.BY
AS SHOWN
@A1
DRAWING TITLE :
PROJECT :
PROPOSED ANNEX BUILDING AT PLOT NO.89, 89A,SIR POCHKHWANWALA
ROAD,WORLI,MUMBAI
NOTES:
1.THIS DRAWING IS THE PROPERTY OF ASSOCIATED CONSULTANTS
& CANNOT BE USED WITHOUT THEIR WRITTEN PERMISSION.
2.DRAWING SHALL NOT BE SCALED WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3.THIS DRAWING TO BE READ ALONG WITH OTHER RELEVANT DRAWINGS.
4.ANY VARIATION BETWEEN THE DRAWING & THE SPECIFICATION, SHOULD BE BROUGHT
TO THE NOTICE OF THE ARCHITECTS BY THE CONTRACTORS IN WRITTING PRIOR TO
CONSTRUCTION.
DWN. CHKD. APPD.DATEREV.
ADC-123 30.06.15 TPS USJ
DESCRIPTION
MAHARASHTRA STATE POLICE HOUSING &
WELFARE CORPORATION LTD
R00.
ASSOCIATED CONSULTANTS
CONSULTING ENGINEERS
A-801, SAI TIRTH, SIDDHARTH
NAGAR, KOPRI,
THANE (E),400603.
TEL- 25327085,25325604,
# FAX 25361721
9. All buildings shall have tie beams/plinth beams at ground/plinth level.
75I
NOTES:
4. Clear covers
2. Due care shall be taken to ascertain that requisite strength of concrete is gained
1. Basic referance code:- IS 456: 2000, IS 1893, IS 13920
12. Fire rating considered:- 2 Hour Max.
40
75
20
25
9. Design is valid for number of floors as indicated in the drawing.
8. If footings overlap each other, necessary revision shall be obtained from our office.
10. At any level where column size gets reduced in either dimension tie beams/plinth beams are essential.
11. For cantilevers, top bars to be anchored behind from external face of support for -1.5 X span of cantilever.
II
VI
SlabsIV
V
Columns & walls >200mm width
Pile cap
Beams
5. Beams having depth more than 750mm, provide side-face reinforcement.
Footings
6. Substratum shall be approved from our office before laying P.C.C.
7. Minimum clear spacing between any two longitudinal bars in beam= 50mm.
8. All laps (Ld) shall be staggered & not more than 50% bars to be lapped
any injury to any personnel arising out of any accidents.
Accidents occurring due to premature deshuttering, faulty / substandard construction material or
Correctness/safety of any temporary structure, scaffolding, shuttering, centering erected at site and
Safety of construction worker/any personnel at work site during construction
1. Our responsibility shall remain limited to safe and sound structural design as transmitted
Safety of old structure during demolition.
Safety of any adjoining building /persons staying in adjoining building/persons
c)
d)
e)
a)
b)
3. All structural concrete should be weigh batched, machine mixed & mechanically vibrated.
Any accident occurring due to construction of elements of buildings not designed by us.
2. Supervision if specifically asked for will be provided to the extent of verification of reinforcement on site
f)
Use of this drawing for construction shall explicitly confirm acceptance of following conditions
25III Columns & walls having width of 200mm & below
4. Any discrepancy between our drawing & Architects' drawing shall be brought to our notice before construction.
5. This drawing is property of ASSOCIATED CONSULTANTS and shall not be reproduced or used
at any given section. Ld = 50 X D (where D= dia. of Bar)
before commencement of deshuttering. It shall comply with provisions of Clause No. 11.3 of IS 456: 2000.
by Owner / Builder / Contractor
by this drawing and we shall not remain responsible for
and properties on adjoining roads.
workmanship / faulty construction procedure.
but responsibility regarding correct & sound construction shall solely rest with contractor/ builder / owner.
without explicit permission of this office.
3. Earthquake zone considered is zone III for Mumbai region.
304,Sentinel ,Hiranandani Business Park,
Powai,Mumbai - 400 076,Maharashtra,India.
T: +91 22 6691 9400 F: +91 22 6692 4077
w w w . s a n k a l p a n . c o m
4. PROPER CARE SHOULD BE TAKEN AT THE JUNCTION OF WALL AND SLAB
3. WATER PROOFING COMPOUND TO BE ADDED TO THE CONCRETE
2. USE CONCRETE MIX M:30 FOR ALL CONCRETE WORKS.
1. STRUCTURE IS DESIGNED AS WATER RETAINING STRUCTURE.
5. PROPER DENSE CONCRETING SHOULD BE DONE
6. THE BOTTOM SLAB OF O.H TANK SHOULD BE CHECKED FOR ANY LEAKAGES ONCE THE SLAB IS
CASTED & THE SAME SHOULD BE RECTIFIED WITH NO EXTRA COST TO OWNER.
4-T20 4-T20 4-T20
4-T16 4-T164-T16
WB2,3 2301850
-
3-T164-T16
- -
2-T20
-
-
-
WALL BEAM
WALL BEAM
WALL BEAM
TPS USJ USJ30.06.15ISSUED FOR TENDER
-
BEAM SCHEDULE
REMARKSSHEAR STIRRUPS
STRAIGHT EXTRA
LEFT SUPP
EXTRA
RIGHT SUPP
TOP REINFORCEMENT
STRAIGHT CURTAILED
BOTTOM REINFORCEMENT
BD
SIZE
NUMBERS
BEAM
B4 900 230
-
2-T12
2-T25- -
T8@100
(CANTILEVER)
B1 900 230
-
3-T16
2-T12- -
T8@150
B2 900 230
-
3-T16
3-T12- -
T8@200
B3 600 150
-
2-T12
2-T10- -
T8@200
B5 900 2303-T16
-3-T12
- -
T8@150 300 MM INVERTED BEAM
300 MM INVERTED BEAM
300 MM INVERTED BEAM
300 MM INVERTED BEAM
-
-
PROJECT STAGE :
TENDER DRAWING
ADC-123-120-R00
STRUCTURAL CONSULTANT
CLIENT:
JOB NO. SCALE DATE DWN.BY CHK.BY
AS SHOWN
@A1
DRAWING TITLE :
PROJECT :
PROPOSED ANNEX BUILDING AT PLOT NO.89, 89A,SIR POCHKHWANWALA
ROAD,WORLI,MUMBAI
NOTES:
1.THIS DRAWING IS THE PROPERTY OF ASSOCIATED CONSULTANTS
& CANNOT BE USED WITHOUT THEIR WRITTEN PERMISSION.
2.DRAWING SHALL NOT BE SCALED WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3.THIS DRAWING TO BE READ ALONG WITH OTHER RELEVANT DRAWINGS.
4.ANY VARIATION BETWEEN THE DRAWING & THE SPECIFICATION, SHOULD BE BROUGHT
TO THE NOTICE OF THE ARCHITECTS BY THE CONTRACTORS IN WRITTING PRIOR TO
CONSTRUCTION.
DWN. CHKD. APPD.DATEREV.
ASC-1983 26.06.15 TPS USJ
DESCRIPTION
MAHARASHTRA STATE POLICE HOUSING &
WELFARE CORPORATION LTD
R00.
ASSOCIATED CONSULTANTS
CONSULTING ENGINEERS
A-801, SAI TIRTH, SIDDHARTH
NAGAR, KOPRI,
THANE (E),400603.
TEL- 25327085,25325604,
# FAX 25361721
9. All buildings shall have tie beams/plinth beams at ground/plinth level.
75I
NOTES:
4. Clear covers
2. Due care shall be taken to ascertain that requisite strength of concrete is gained
1. Basic referance code:- IS 456: 2000, IS 1893, IS 13920
12. Fire rating considered:- 2 Hour Max.
40
75
20
25
9. Design is valid for number of floors as indicated in the drawing.
8. If footings overlap each other, necessary revision shall be obtained from our office.
10. At any level where column size gets reduced in either dimension tie beams/plinth beams are essential.
11. For cantilevers, top bars to be anchored behind from external face of support for -1.5 X span of cantilever.
II
VI
SlabsIV
V
Columns & walls >200mm width
Pile cap
Beams
5. Beams having depth more than 750mm, provide side-face reinforcement.
Footings
6. Substratum shall be approved from our office before laying P.C.C.
7. Minimum clear spacing between any two longitudinal bars in beam= 50mm.
8. All laps (Ld) shall be staggered & not more than 50% bars to be lapped
any injury to any personnel arising out of any accidents.
Accidents occurring due to premature deshuttering, faulty / substandard construction material or
Correctness/safety of any temporary structure, scaffolding, shuttering, centering erected at site and
Safety of construction worker/any personnel at work site during construction
1. Our responsibility shall remain limited to safe and sound structural design as transmitted
Safety of old structure during demolition.
Safety of any adjoining building /persons staying in adjoining building/persons
c)
d)
e)
a)
b)
3. All structural concrete should be weigh batched, machine mixed & mechanically vibrated.
Any accident occurring due to construction of elements of buildings not designed by us.
2. Supervision if specifically asked for will be provided to the extent of verification of reinforcement on site
f)
Use of this drawing for construction shall explicitly confirm acceptance of following conditions
25III Columns & walls having width of 200mm & below
4. Any discrepancy between our drawing & Architects' drawing shall be brought to our notice before construction.
5. This drawing is property of ASSOCIATED CONSULTANTS and shall not be reproduced or used
at any given section. Ld = 50 X D (where D= dia. of Bar)
before commencement of deshuttering. It shall comply with provisions of Clause No. 11.3 of IS 456: 2000.
by Owner / Builder / Contractor
by this drawing and we shall not remain responsible for
and properties on adjoining roads.
workmanship / faulty construction procedure.
but responsibility regarding correct & sound construction shall solely rest with contractor/ builder / owner.
without explicit permission of this office.
3. Earthquake zone considered is zone III for Mumbai region.
4. PROPER CARE SHOULD BE TAKEN AT THE JUNCTION OF WALL AND SLAB
3. WATER PROOFING COMPOUND TO BE ADDED TO THE CONCRETE
2. USE CONCRETE MIX M:30 FOR ALL CONCRETE WORKS.
1. STRUCTURE IS DESIGNED AS WATER RETAINING STRUCTURE.
5. PROPER DENSE CONCRETING SHOULD BE DONE
6. THE BOTTOM SLAB OF O.H TANK SHOULD BE CHECKED FOR ANY LEAKAGES ONCE THE SLAB IS
CASTED & THE SAME SHOULD BE RECTIFIED WITH NO EXTRA COST TO OWNER.
TPS USJ USJ10-07-15ISSUED FOR TENDER
+300 MM FFL
± 00 MM FFL
+4350 MM FFL
+7350 MM FFL
+10350 MM FFL
+13350 MM FFL
+17000 MM FFL
+20650 MM FFL
+1350 MM FFL
+24225 MM SSL
GROUND LEVEL
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
TERRACE FLOOR
GROUND FLOOR LEVEL
EXISTING BLDG PLINTH LEVEL
C7BC6A
C4A
C2A
C1
C2
C3
C4
C5
C6
C7
C7A
C7/FC5/FC5A
FC7 FC7A FC6 FC6A
B6 B7 B8 B9 B10 B11B5
FC1 FC2 FC3
(FC4A,FC5A FROM 4TH FLOOR)
C6/FC4/FC4A
PROJECT STAGE :
TENDER DRAWING
ADC-123-121-R00
STRUCTURAL CONSULTANT
CLIENT:
JOB NO. SCALE DATE DWN.BY CHK.BY
AS SHOWN
@A1
DRAWING TITLE :
R.C.C ELEVATIONAL DETAILS OF COLUMNS
PROJECT :
PROPOSED ANNEX BUILDING AT PLOT NO.89, 89A,SIR POCHKHWANWALA
ROAD,WORLI,MUMBAI
NOTES:
1.THIS DRAWING IS THE PROPERTY OF ASSOCIATED CONSULTANTS
& CANNOT BE USED WITHOUT THEIR WRITTEN PERMISSION.
2.DRAWING SHALL NOT BE SCALED WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3.THIS DRAWING TO BE READ ALONG WITH OTHER RELEVANT DRAWINGS.
4.ANY VARIATION BETWEEN THE DRAWING & THE SPECIFICATION, SHOULD BE BROUGHT
TO THE NOTICE OF THE ARCHITECTS BY THE CONTRACTORS IN WRITTING PRIOR TO
CONSTRUCTION.
DWN. CHKD. APPD.DATEREV.
ADC-123 15.06.15 TPS USJ
DESCRIPTION
REFERENCE DRAWINGS
DRG.NO.DRAWING TITLE
MAHARASHTRA STATE POLICE HOUSING &
WELFARE CORPORATION LTD
R.C.C DETAILS OF COLUMN
ASC-1983-121-R00
R00.
ASSOCIATED CONSULTANTS
CONSULTING ENGINEERS
A-801, SAI TIRTH, SIDDHARTH
NAGAR, KOPRI,
THANE (E),400603.
TEL- 25327085,25325604,
# FAX 25361721
9. All buildings shall have tie beams/plinth beams at ground/plinth level.
75I
NOTES:
4. Clear covers
2. Due care shall be taken to ascertain that requisite strength of concrete is gained
1. Basic referance code:- IS 456: 2000, IS 1893, IS 13920
12. Fire rating considered:- 2 Hour Max.
40
75
20
25
9. Design is valid for number of floors as indicated in the drawing.
8. If footings overlap each other, necessary revision shall be obtained from our office.
10. At any level where column size gets reduced in either dimension tie beams/plinth beams are essential.
11. For cantilevers, top bars to be anchored behind from external face of support for -1.5 X span of cantilever.
II
VI
SlabsIV
V
Columns & walls >200mm width
Pile cap
Beams
5. Beams having depth more than 750mm, provide side-face reinforcement.
Footings
6. Substratum shall be approved from our office before laying P.C.C.
7. Minimum clear spacing between any two longitudinal bars in beam= 50mm.
8. All laps (Ld) shall be staggered & not more than 50% bars to be lapped
any injury to any personnel arising out of any accidents.
Accidents occurring due to premature deshuttering, faulty / substandard construction material or
Correctness/safety of any temporary structure, scaffolding, shuttering, centering erected at site and
Safety of construction worker/any personnel at work site during construction
1. Our responsibility shall remain limited to safe and sound structural design as transmitted
Safety of old structure during demolition.
Safety of any adjoining building /persons staying in adjoining building/persons
c)
d)
e)
a)
b)
3. All structural concrete should be weigh batched, machine mixed & mechanically vibrated.
Any accident occurring due to construction of elements of buildings not designed by us.
2. Supervision if specifically asked for will be provided to the extent of verification of reinforcement on site
f)
Use of this drawing for construction shall explicitly confirm acceptance of following conditions
25III Columns & walls having width of 200mm & below
4. Any discrepancy between our drawing & Architects' drawing shall be brought to our notice before construction.
5. This drawing is property of ASSOCIATED CONSULTANTS and shall not be reproduced or used
at any given section. Ld = 50 X D (where D= dia. of Bar)
before commencement of deshuttering. It shall comply with provisions of Clause No. 11.3 of IS 456: 2000.
by Owner / Builder / Contractor
by this drawing and we shall not remain responsible for
and properties on adjoining roads.
workmanship / faulty construction procedure.
but responsibility regarding correct & sound construction shall solely rest with contractor/ builder / owner.
without explicit permission of this office.
3. Earthquake zone considered is zone III for Mumbai region.
3 0 4 , S e n t i n e l , H i r a n a n d a n i B u s i n e s s P a r k ,
P o w a i , M u m b a i - 4 0 0 0 7 6 , M a h a r a s h t r a , I n d i a .
T : + 9 1 2 2 6 6 9 1 9 4 0 0 F : + 9 1 2 2 6 6 9 2 4 0 7 7
w w w . s a n k a l p a n . c o m
2. MAX.100∅ SLEEVES ARE ALLOWED IN BEAM
(MAX.2NOS PER BEAM ). THE LOCATION OF TOP OF
1. FILLING WORK AT ANY RAISED OR SUNK PORTION
SHOULD BE STRICTLY IN LIGHT WEIGHT (AAC) BLOCK ONLY.
SLEEVE SHALL BE 300 MM FROM TOP OF BEAM
3. FOR P.T. BEAM DETAILS REFER P.T. CONSULTANT'S DWG.
30.07.15 TPS USJUSJISSUED FOR TENDER
PROJECT STAGE :
TENDER DRAWING
ADC-123-122-R00
STRUCTURAL CONSULTANT
CLIENT:
JOB NO. SCALE DATE DWN.BY CHK.BY
AS SHOWN
@A1
DRAWING TITLE :
R.C.C DETAILS OF 4TH FLOOR SLAB P.T. BEAMS
PROJECT :
PROPOSED ANNEX BUILDING AT PLOT NO.89, 89A,SIR POCHKHWANWALA
ROAD,WORLI,MUMBAI
NOTES:
1.THIS DRAWING IS THE PROPERTY OF ASSOCIATED CONSULTANTS
& CANNOT BE USED WITHOUT THEIR WRITTEN PERMISSION.
2.DRAWING SHALL NOT BE SCALED WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3.THIS DRAWING TO BE READ ALONG WITH OTHER RELEVANT DRAWINGS.
4.ANY VARIATION BETWEEN THE DRAWING & THE SPECIFICATION, SHOULD BE BROUGHT
TO THE NOTICE OF THE ARCHITECTS BY THE CONTRACTORS IN WRITTING PRIOR TO
CONSTRUCTION.
DWN. CHKD.APPD.DATEREV.
ADC-123 20.08.15 HIMALI
DESCRIPTION
REFERENCE DRAWINGS
DRG.NO. DRAWING TITLE
MAHARASHTRA STATE POLICE HOUSING &
WELFARE CORPORATION LTD
R.C.C DETAILS OF 4TH FLOOR PLANADC-123-111-R00
ASSOCIATED CONSULTANTS
CONSULTING ENGINEERS
A-801, SAI TIRTH, SIDDHARTH
NAGAR, KOPRI,
THANE (E),400603.
TEL- 25327085,25325604,
# FAX 25361721
304,Sentinel ,Hiranandani Business Park,
Powai,Mumbai - 400 076,Maharashtra,India.
T: +91 22 6691 9400 F: +91 22 6692 4077
w w w . s a n k a l p a n . c o m
R00. 20.08.2015ISSUED FOR TENDER HIMALI
M/S. TOTO POST TENSIONING SERVICES PVT.LTD.
P.T. CONSULTANT
UPDN
FC1FC2
FC3
C10 C12
C13
C19
C22
C14
C26C23 C24
C15
C21
C25
C20
FC4 FC5
B1
B2 B2 B2 B2
B3
B4B5 B6
B8 B9 B10 B11
B18
B19B20
B21
B22
B23
B24
B25 B26 B27 MB MBKT2
B29MB1
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B48
B49
B50
B51
B51
B52
B53
B55
B56
B57
6"LIGHT WEIGHTBRICK WALL
TOILET
RAISED
B4
HB
HB
A
A1
HB
E1
B
B1
FC7 B14A
HB
1
HCPT BEAM 2 = 1000 X 600
PT BEAM 1 = 1000 X 600
UPDN
FC1FC2
FC3
C10 C12
C13
C19
C22
C14
C26C23 C24
C15
C21
C25
C20
FC4 FC5
B1
B2 B2 B2 B2
B3
B4B5 B6
B8 B9 B10 B11B12
B18
B19B20
B21
B22
B23
B25 B26 B27 MB MBKT2
B29MB1
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B48
B49
B50
B51
B51
B52
B53
B55
B56
B57
6"LIGHT WEIGHTBRICK WALL
TOILET
RAISED
B4
HB
HB
A
A1
HB
E1
B
B1
C1
FC7 B14A
HB
1
HC
C10 C12
PT BEAM 1 & 2 = 1000 X 600
CGS
L
450 380 255165
110 90110 255 380
450
165
3.7 7.4 9.311.1 14.9 19.20.0
1.85.5
1316.7
10 Ø 32 Ø 10 MM @150 MM C/C 6 L 10 Ø 32
10 Ø 32 10 Ø 32 Ø 10 MM @ 150 MM C/C 6 L
Ø 10 MM @ 150 MM C/C 6 L
Ø 10 MM @ 150 MM C/C 6 L
Ø 10 MM @ 200 MM C/C 6 L
Ø 10 MM @ 200 MM C/C 6 L
NOTES:
1) ALL DIMENSION ARE IN MM
2) CONCRETE CLEAR COVER FOR BEAM:
TOP: 40mm TO THE NEAREST REINFT.
BTM: 40mm TO THE NEAREST REINFT.
CONCRETE CLEAR COVER FOR SLAB:
TOP: 25MM TO THE NEAREST REINFT.
BTM: 25MM TO THE NEAREST REINFT.
3)ONE NUMBER OF TENDON WILL BE TENSIONED AT 140KN.
4)TENDON SPECIFICATION
· . OF STRANDS = 12.7MM,7ply,LRPS
· AREA = 99MM2
· UTS VALUE = 1860/MM2
MADE AS PER IS 14268
5) GRADE OF STEEL = Fe415, GRADE OF CONCRETE =M40
6) ALL LAPPING LENGTH SHALL BE FOLLOWED AS PER THE CONSULTANT
DWGAND LAPS SHOULD BE KEPT STAGGERED.
7) 50% PROPS SHALL BE RETAINED AT LOWER LEVEL SLAB WHILE
CASTING OF THE CURRENT SLAB
8) THIS PROPS MUST BE RETAINED TILL STRESSING OF ALL CABLES AT
CURRENT LEVEL
9) MINIMUM STRENGTH OF CONCRETE REQUIRED BEFORE STRESSING =
25N/MM2
10) AS PER SITE SITUATION DEAD END AND LIVE END CAN BE CHANGED
11) LOAD CONSIDERED:
A) DEAD LOAD = 2KN/M2
B) LIVE LOAD = 5KN/M2
C) FC COLUMN LOAD = 250KN
D) SELF WEIGHT AS PER ACTUAL
PROJECT STAGE :
TENDER DRAWING
ADC-123-123-R00
STRUCTURAL CONSULTANT
CLIENT:
JOB NO. SCALE DATE DWN.BY CHK.BY
AS SHOWN
@A1
DRAWING TITLE :
R.C.C DETAILS OF 5 TH FLOOR SLAB P.T. BEAMS
PROJECT :
PROPOSED ANNEX BUILDING AT PLOT NO.89, 89A,SIR POCHKHWANWALA
ROAD,WORLI,MUMBAI
NOTES:
1.THIS DRAWING IS THE PROPERTY OF ASSOCIATED CONSULTANTS
& CANNOT BE USED WITHOUT THEIR WRITTEN PERMISSION.
2.DRAWING SHALL NOT BE SCALED WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3.THIS DRAWING TO BE READ ALONG WITH OTHER RELEVANT DRAWINGS.
4.ANY VARIATION BETWEEN THE DRAWING & THE SPECIFICATION, SHOULD BE BROUGHT
TO THE NOTICE OF THE ARCHITECTS BY THE CONTRACTORS IN WRITTING PRIOR TO
CONSTRUCTION.
DWN. CHKD.APPD.DATEREV.
ADC-123 20.08.15 HIMALI
DESCRIPTION
REFERENCE DRAWINGS
DRG.NO. DRAWING TITLE
MAHARASHTRA STATE POLICE HOUSING &
WELFARE CORPORATION LTD
R.C.C DETAILS OF 5TH FLOOR PLANADC-123-113-R00
ASSOCIATED CONSULTANTS
CONSULTING ENGINEERS
A-801, SAI TIRTH, SIDDHARTH
NAGAR, KOPRI,
THANE (E),400603.
TEL- 25327085,25325604,
# FAX 25361721
304,Sentinel ,Hiranandani Business Park,
Powai,Mumbai - 400 076,Maharashtra,India.
T: +91 22 6691 9400 F: +91 22 6692 4077
w w w . s a n k a l p a n . c o m
R00. 20.08.2015ISSUED FOR TENDER HIMALI
M/S. TOTO POST TENSIONING SERVICES PVT.LTD.
P.T. CONSULTANT
UPDN
FC1FC2
FC3
C10 C12
C13
C19
C22
C14
C26C23 C24
C15
C21
C25
C20
B1
B2 B2 B2 B2
B3
B4
B8 B9 B10 B11 B12
B14 B15B13
B16
B17 B18
B19
B21 B22 B23 MBKT2
B25
B26
B27
B28
B29
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B47
B48
B49
B50
B51
B52
B53
MB
MB1
HB
HB
6"LIGHT WEIGHTBRICK WALL
TOILET
RAISED
A B
E1
F
UPDN
FC1FC2
FC3
C10 C12
C13
C19
C22
C14
C26C23 C24
C15
C21
C25
C20
B1
B2 B2 B2 B2
B3
B4
B8 B9 B10 B11 B12
B14 B15B13
B16
B17 B18
B19
B20
B21 B22 B23 MBKT2
B25
B26
B27
B28
B29
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B47
B48
B49
B50
B51
B52
B53
MB
MB1
HB
HB
6"LIGHT WEIGHTBRICK WALL
TOILET
RAISED
A B
E1
F
PT BEAM 2 = 1000 X 600
PT BEAM 1 = 1000 X 600
PT BEAM 3 = 1700 X 600 PT BEAM 3 = 1700 X 600 PT BEAM 3 = 1700 X 600
PT BEAM 3 = 1700 X 600 PT BEAM 3 = 1700 X 600 PT BEAM 3 = 1700 X 600FC1 FC2 FC3
CGS
L
300 225 170 120 110160
290 510 400300
430
2.3 4.65 6.0 7.4
9.3
11.60.0 1.4 3.78.4
10.7
250
12.5
220
13.5
215
14.0
250
15.3
350
16.7
450
17.7
510
18.6
490
19.8
450
20.7
415
21.6
360
23.1
300
24.9
8 Ø 32 Ø 10 MM @150 MM C/C 6 L 8 Ø 25
8 Ø 32 8 Ø 25 Ø 10 MM @ 150 MM C/C 6 L
Ø 10 MM @ 150 MM C/C 6 L
Ø 10 MM @ 150 MM C/C 6 L
2 Ø 32
2 Ø 32
Ø 10 MM @ 200 MM C/C 6 L
Ø 10 MM @ 200 MM C/C 6 L
8 Ø 32 8 Ø 25 Ø 10 MM @ 150 MM C/C 6 L Ø 10 MM @ 150 MM C/C 6 LØ 10 MM @ 200 MM C/C 6 L
12 Ø 32 12 Ø 25
12 Ø 32 12 Ø 25 Ø 10 MM @ 150 MM C/C 8 L Ø 10 MM @ 150 MM C/C 8 L Ø 10 MM @ 150 MM C/C 8 L
Ø 10 MM @ 150 MM C/C 8 LØ 10 MM @ 150 MM C/C 8 LØ 10 MM @ 150 MM C/C 6 L
CGS
L
450 380255 165
110 90110 255
380450
165
3.7 7.4 9.311.1 14.9 19.20.0
1.85.5
1316.7
C10 C12
PT BEAM 1 & 2 = 1000 X 600
BEAM TENDON DETAIL PLAN
SHUTTERING DRAWING
SECTION
SECTION
NOTES:
1) ALL DIMENSION ARE IN MM
2) CONCRETE CLEAR COVER FOR BEAM:
TOP: 40mm TO THE NEAREST REINFT.
BTM: 40mm TO THE NEAREST REINFT.
CONCRETE CLEAR COVER FOR SLAB:
TOP: 25MM TO THE NEAREST REINFT.
BTM: 25MM TO THE NEAREST REINFT.
3)ONE NUMBER OF TENDON WILL BE TENSIONED AT 140KN.
4)TENDON SPECIFICATION
· . OF STRANDS = 12.7MM,7ply,LRPS
· AREA = 99MM2
· UTS VALUE = 1860/MM2
MADE AS PER IS 14268
5) GRADE OF STEEL = Fe415, GRADE OF CONCRETE =M40
6) ALL LAPPING LENGTH SHALL BE FOLLOWED AS PER THE CONSULTANT
DWGAND LAPS SHOULD BE KEPT STAGGERED.
7) 50% PROPS SHALL BE RETAINED AT LOWER LEVEL SLAB WHILE
CASTING OF THE CURRENT SLAB
8) THIS PROPS MUST BE RETAINED TILL STRESSING OF ALL CABLES AT
CURRENT LEVEL
9) MINIMUM STRENGTH OF CONCRETE REQUIRED BEFORE STRESSING =
25N/MM2
10) AS PER SITE SITUATION DEAD END AND LIVE END CAN BE CHANGED
11) LOAD CONSIDERED:
A) DEAD LOAD = 2KN/M2
B) LIVE LOAD = 5KN/M2
C) FC COLUMN LOAD = 250KN
D) SELF WEIGHT AS PER ACTUAL
PROJECT STAGE :
TENDER DRAWING
ADC-123-124-R00
STRUCTURAL CONSULTANT
CLIENT:
JOB NO. SCALE DATE DWN.BY CHK.BY
AS SHOWN
@A1
DRAWING TITLE :
R.C.C DETAILS OF 6TH FLOOR SLAB P.T. BEAMS
PROJECT :
PROPOSED ANNEX BUILDING AT PLOT NO.89, 89A,SIR POCHKHWANWALA
ROAD,WORLI,MUMBAI
NOTES:
1.THIS DRAWING IS THE PROPERTY OF ASSOCIATED CONSULTANTS
& CANNOT BE USED WITHOUT THEIR WRITTEN PERMISSION.
2.DRAWING SHALL NOT BE SCALED WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3.THIS DRAWING TO BE READ ALONG WITH OTHER RELEVANT DRAWINGS.
4.ANY VARIATION BETWEEN THE DRAWING & THE SPECIFICATION, SHOULD BE BROUGHT
TO THE NOTICE OF THE ARCHITECTS BY THE CONTRACTORS IN WRITTING PRIOR TO
CONSTRUCTION.
DWN. CHKD.APPD.DATEREV.
ADC-123 20.08.15 HIMALI
DESCRIPTION
REFERENCE DRAWINGS
DRG.NO. DRAWING TITLE
MAHARASHTRA STATE POLICE HOUSING &
WELFARE CORPORATION LTD
R.C.C DETAILS OF SIXTH FLOOR PLANADC-123-115-R00
ASSOCIATED CONSULTANTS
CONSULTING ENGINEERS
A-801, SAI TIRTH, SIDDHARTH
NAGAR, KOPRI,
THANE (E),400603.
TEL- 25327085,25325604,
# FAX 25361721
NOTES:
304,Sentinel ,Hiranandani Business Park,
Powai,Mumbai - 400 076,Maharashtra,India.
T: +91 22 6691 9400 F: +91 22 6692 4077
w w w . s a n k a l p a n . c o m
R00. 20.08.2015ISSUED FOR TENDER HIMALI
M/S. TOTO POST TENSIONING SERVICES PVT.LTD.
P.T. CONSULTANT
1) ALL DIMENSION ARE IN MM
2) CONCRETE CLEAR COVER FOR BEAM:
TOP: 40mm TO THE NEAREST REINFT.
BTM: 40mm TO THE NEAREST REINFT.
CONCRETE CLEAR COVER FOR SLAB:
TOP: 25MM TO THE NEAREST REINFT.
BTM: 25MM TO THE NEAREST REINFT.
3)ONE NUMBER OF TENDON WILL BE TENSIONED AT 140KN.
4)TENDON SPECIFICATION
· . OF STRANDS = 12.7MM,7ply,LRPS
· AREA = 99MM2
· UTS VALUE = 1860/MM2
MADE AS PER IS 14268
5) GRADE OF STEEL = Fe415, GRADE OF CONCRETE =M40
6) ALL LAPPING LENGTH SHALL BE FOLLOWED AS PER THE CONSULTANT
DWGAND LAPS SHOULD BE KEPT STAGGERED.
7) 50% PROPS SHALL BE RETAINED AT LOWER LEVEL SLAB WHILE
CASTING OF THE CURRENT SLAB
8) THIS PROPS MUST BE RETAINED TILL STRESSING OF ALL CABLES AT
CURRENT LEVEL
9) MINIMUM STRENGTH OF CONCRETE REQUIRED BEFORE STRESSING =
25N/MM2
10) AS PER SITE SITUATION DEAD END AND LIVE END CAN BE CHANGED
11) LOAD CONSIDERED:
A) DEAD LOAD = 2KN/M2
B) LIVE LOAD = 5KN/M2
C) FC COLUMN LOAD = 250KN
D) SELF WEIGHT AS PER ACTUAL
UPDN
FC1FC2
FC3
C10 C12
C13
C19
C22
C14
C26C23 C24
C15
C21
C25
C20
B1
B2 B2 B2 B2
B3
B4B5 B6
B8 B9 B10 B11
B14
B15
B13
B16
B17 B18
B19
B20
B21 B22 B23 MBKT2
B25
B26
B27
B28
B29
B30
B31
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B47
B48
B49
B52
B53
MB
MB1
HB
HB
6"LIGHT WEIGHTBRICK WALL
TOILET
RAISED
E1
C1
B32
PT BEAM 2 = 1000 X 600
PT BEAM 1 = 1000 X 600
UPDN
FC1FC2
FC3
C10 C12
C13
C19
C22
C14
C26C23 C24
C15
C21
C25
C20
B1
B2 B2 B2 B2
B3
B4B5 B6
B8 B9 B10 B11
B14
B15
B13
B16
B17 B18
B19
B20
B21 B22 B23 MBKT2
B25
B26
B27
B28
B29
B30
B31
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B47
B48
B49
B52
B53
MB
MB1
HB
HB
6"LIGHT WEIGHTBRICK WALL
TOILET
RAISED
E1
C1
B32
10 Ø 32 Ø 10 MM @150 MM C/C 6 L 10 Ø 32
10 Ø 32 10 Ø 32 Ø 10 MM @ 150 MM C/C 6 L
Ø 10 MM @ 150 MM C/C 6 L
Ø 10 MM @ 150 MM C/C 6 L
Ø 10 MM @ 200 MM C/C 6 L
Ø 10 MM @ 200 MM C/C 6 L
CGS
L
450 380 255 165110 90
110 255380
450
165
3.7 7.4 9.311.1 14.9 19.20.0
1.8 5.513
16.7
C10 C12
PT BEAM 1 & 2 = 1000 X 600
PROJECT STAGE :
TENDER DRAWING
ADC-123-125-R00
STRUCTURAL CONSULTANT
CLIENT:
JOB NO. SCALE DATE DWN.BY CHK.BY
AS SHOWN
@A1
DRAWING TITLE :
R.C.C DETAILS OF TERRACE FLOOR SLAB P.T. BEAMS
PROJECT :
PROPOSED ANNEX BUILDING AT PLOT NO.89, 89A,SIR POCHKHWANWALA
ROAD,WORLI,MUMBAI
NOTES:
1.THIS DRAWING IS THE PROPERTY OF ASSOCIATED CONSULTANTS
& CANNOT BE USED WITHOUT THEIR WRITTEN PERMISSION.
2.DRAWING SHALL NOT BE SCALED WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3.THIS DRAWING TO BE READ ALONG WITH OTHER RELEVANT DRAWINGS.
4.ANY VARIATION BETWEEN THE DRAWING & THE SPECIFICATION, SHOULD BE BROUGHT
TO THE NOTICE OF THE ARCHITECTS BY THE CONTRACTORS IN WRITTING PRIOR TO
CONSTRUCTION.
DWN. CHKD.APPD.DATEREV.
ADC-123 20.08.15 HIMALI
DESCRIPTION
REFERENCE DRAWINGS
DRG.NO. DRAWING TITLE
MAHARASHTRA STATE POLICE HOUSING &
WELFARE CORPORATION LTD
R.C.C DETAILS OF TERRACE FLOOR PLANADC-123-117-R00
ASSOCIATED CONSULTANTS
CONSULTING ENGINEERS
A-801, SAI TIRTH, SIDDHARTH
NAGAR, KOPRI,
THANE (E),400603.
TEL- 25327085,25325604,
# FAX 25361721
NOTES:
304,Sentinel ,Hiranandani Business Park,
Powai,Mumbai - 400 076,Maharashtra,India.
T: +91 22 6691 9400 F: +91 22 6692 4077
w w w . s a n k a l p a n . c o m
R00. 20.08.2015ISSUED FOR TENDER HIMALI
M/S. TOTO POST TENSIONING SERVICES PVT.LTD.
P.T. CONSULTANT
UPDN
C6FC1
FC2
FC3
C10 C12
C13
C19
C22
C14
C26C23 C24
C15
C21
C25
C20
FC4
B1
B2 B2 B2 B2
B3
B4B5 B6 B7
B8 B9 B10 B11 B12
B14 B15B13
B17
B19
B20
B21 B22 B23
B25
B26
B27
B28
B29
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B47
B48
B49
MB
MB1B
E1
FC4
B50
B51
B52
B53
B2A
FC
FC
PT BEAM 2 = 1200 X 650
PT BEAM 1 = 1200 X 650
UPDN
C6FC1
FC2
FC3
C10 C12
C13
C19
C22
C14
C26C23 C24
C15
C21
C25
C20
FC4
B1
B2 B2 B2 B2
B3
B4B5 B6 B7
B8 B9 B10 B11 B12
B14 B15B13
B17
B19
B20
B21 B22 B23
B25
B26
B27
B28
B29
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B47
B48
B49
MB
MB1B
E1
FC4
B50
B51
B52
B53
B2A
FC
FC
10 Ø 32 Ø 10 MM @150 MM C/C 8 L 10 Ø 32
10 Ø 32 10 Ø 32 Ø 10 MM @ 150 MM C/C 8 L
Ø 10 MM @ 150 MM C/C 8 L
Ø 10 MM @ 150 MM C/C 8 L
C10 C12PT BEAM 1 = 1200 X 650
CGS
L
500 400 230130 100
115150 315 430
500
220
3.77.5
9.3 11.2
14.9
19.20.0 1.9 5.613
16.8
Ø 10 MM @ 200 MM C/C 8 L
Ø 10 MM @ 200 MM C/C 8 L
1) ALL DIMENSION ARE IN MM
2) CONCRETE CLEAR COVER FOR BEAM:
TOP: 40mm TO THE NEAREST REINFT.
BTM: 40mm TO THE NEAREST REINFT.
CONCRETE CLEAR COVER FOR SLAB:
TOP: 25MM TO THE NEAREST REINFT.
BTM: 25MM TO THE NEAREST REINFT.
3)ONE NUMBER OF TENDON WILL BE TENSIONED AT 140KN.
4)TENDON SPECIFICATION
· . OF STRANDS = 12.7MM,7ply,LRPS
· AREA = 99MM2
· UTS VALUE = 1860/MM2
MADE AS PER IS 14268
5) GRADE OF STEEL = Fe415, GRADE OF CONCRETE =M40
6) ALL LAPPING LENGTH SHALL BE FOLLOWED AS PER THE CONSULTANT
DWGAND LAPS SHOULD BE KEPT STAGGERED.
7) 50% PROPS SHALL BE RETAINED AT LOWER LEVEL SLAB WHILE
CASTING OF THE CURRENT SLAB
8) THIS PROPS MUST BE RETAINED TILL STRESSING OF ALL CABLES AT
CURRENT LEVEL
9) MINIMUM STRENGTH OF CONCRETE REQUIRED BEFORE STRESSING =
25N/MM2
10) AS PER SITE SITUATION DEAD END AND LIVE END CAN BE CHANGED
11) LOAD CONSIDERED:
A) DEAD LOAD = 2KN/M2
B) LIVE LOAD = 5KN/M2
C) FC COLUMN LOAD = 250KN
D) SELF WEIGHT AS PER ACTUAL