Page 1: A-1 · wh hb plan notes 1) verify all rough opening dimensions for all windows and doors 2) provide safety glazing within 24" from exit per florida building code r 308.4.2
Page 2: A-1 · wh hb plan notes 1) verify all rough opening dimensions for all windows and doors 2) provide safety glazing within 24" from exit per florida building code r 308.4.2

5"

12"

5"

12"

5"

12"

5"

12"

5"

12"

5"

12"

FINISH FLOORELEV. @ 0"

FINISH FLOORELEV. @ 0"

TOP OF BEAMELEV. @ 8'-0"

TOP OF BEAMELEV. @ 8'-0"

1'-0"1'-0"

6'-8

"

25 SH3068 FRONT ENTRY DR.

16'-0 X 7'-0" O.H. GARGAE DOOR

FYPON 12X24

8'-0

"

FINISH FLOORELEV. @ 0"

FINISH FLOORELEV. @ 0"

TOP OF BEAMELEV. @ 8'-0"

TOP OF BEAMELEV. @ 8'-0"

1'-0"1'-0"

6'-8

"

35 SH2-25 SH2-3068 SL GL DR

SHINGLE ROOF

FINISH FLOORELEV. @ 0"

FINISH FLOORELEV. @ 0"

TOP OF BEAMELEV. @ 8'-0"

TOP OF BEAMELEV. @ 8'-0"

6'-8

"

25 SH

ELECTRIC METERVERIFY LOCATION

A/C

A/C DISCONNECTDECO. TEXTURE FIN. ON

CONC. BLK.WALL

SHINGLE ROOF

1'-0"

FINISH FLOORELEV. @ 0"

FINISH FLOORELEV. @ 0"

TOP OF BEAMELEV. @ 8'-0"

TOP OF BEAMELEV. @ 8'-0"

6'-8

"

1'-0"

25 SH

DECO. TEXTURE FIN. ON CONC.

BLK. WALL

SHINGLE ROOF

1'-0"

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

1/4" = 1'-0"

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\G

ULF

CO

VE S

PO

T

LOTS\1

1048 L

OT 1

8 B

LK 1

837 1

499 A

L\REVIT

\11048 1

499 A

L.rv

t

A-1

ELEVATION

#1499 A

MO

DEL

JWC

JSL

09/17/19

LOT:

18

BLO

CK:

183

7

SUBD

IVIS

ION:

GULF

CO

VE S

PO

T L

OTS

AD

DRS:

547

3 H

OFFM

AN S

T

D.R

.H.

#:

57

95

00

022

GC

D J

OB #

11

048

1/4" = 1'-0"

FRONT ELEVATION1/4" = 1'-0"

REAR ELEVATION

1/4" = 1'-0"

LEFT ELEVATION

1/4" = 1'-0"

RIGHT ELEVATION

SHINGLE ROOF

Page 3: A-1 · wh hb plan notes 1) verify all rough opening dimensions for all windows and doors 2) provide safety glazing within 24" from exit per florida building code r 308.4.2

WH

HB

5'-0

"5

0'-0

"

38'-0"

38'-0"

1'-7" 16'-0" 1'-7" 4'-2" 14'-8"

18'-11" 12'-0" 2'-6 1/2" 2'-6" 2'-0 1/2"

2'-2" 2'-10" 3'-0" 7'-3 1/2" 22'-8 1/2"

18'-6 1/2" 14'-9 1/2" 4'-8"

14'-8" 14'-6" 8'-10"

28'-10" 7'-0" 2'-2"

5'-0

"5

0'-0

"

ELEV @ 0'-(-4")

2" SLO

PE

16'-0" X 7'-0" O.H. GARAGE DR.

6" X 12" RECESS

ELEV @ 4"

PAVER BY

OTHERS

SET A/C PAD

ABOVE FLOOD W/

1'-0" FREEBOARD

PER FBCR

R322.2.1

RANGE

RUN CODUIT FOR

ELECTRIC AT ISLAND

DBL SINK

DW

PROVIDE 1/4" WATER

LINE @ REF. SPACE FOR

ICE MAKER

PAVER BY OTHERS

STANDARD SGD RECESS 1-1/2". IMPACT

GLASS SGD RECESS 2-1/2".

ELEV @ 0'-(-4")

20

'-8

"1

0'-0

"3

'-0

1/2

"2

'-1

0"

13

'-5

1/2

"

13

'-2

"9

'-3

1/2

"1

0'-4

"5

'-1

1"

7'-3

1/2

"4

'-0

"

5'-0

" TUB

DRYERWASHER

REF. SPACE

FIB

ERG

LASS

SHW

R

29'-3" 6'-2" 2'-7"

4" SLAB W/ 2,500 PSI CONC. W/ 6X6 #

10/10 W.W.M. REINFORCING OVER 6

MILL VISQUEEN BARRIER ON

MECHANICALLY COMPACTED FILL @ 95%.

THE FINISH FLOOR SLAB SHALL BE SET

ABOVE BASE FLOOD ELEVATION PER FEMA

FLOOD MAP PLUS 1'-0" FREEBOARD PER

FBCR R322.2.1. SEE SITE PLAN BY OTHERS

ELEV. @ 0'-0"

SET W/H ABOVE FLOOD

W/ 1'-0" FREEBOARD PER

FBCR R322.2.1

LOWEST POINT OF GARAGE SHALL BE SET ABOVE

BASE FLOOD ELEVATION PER FEMA FLOOD MAP

1'-6"

1'-7 1/2"

1'-3 1/2" 1'-3"

PROVIDE TERMITE

TREATMENT WITH

"BORA CARE"

OR DOORS

21" MIN. TO

FIXTURES, WALLS 1'-9"

8'-0

"36" MAX.

OR DOORS

21" MIN. TO

FIXTURES, WALLS

MIN.

1'-0"

19

" M

IN.

19

" M

IN.

15" MIN.

TO FINISH

FRONT ELEVATION SIDE ELEVATION

WATER CLOSET CLEARANCE DETAIL

8'-0

"

FRONT ELEVATION SIDE ELEVATION

VANITY SINK CLEARANCE DETAIL

4"

2'-5

1/2

"

8'-0

"

VARIES

4"

2'-5

1/2

"VARIE

S

VARIES

8'-0

"

MIRROR

FAUCET

KICK PLATE

FAUCET

MIRROR

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\G

ULF

CO

VE S

PO

T

LOTS\1

1048 L

OT 1

8 B

LK 1

837 1

499 A

L\REVIT

\11048 1

499 A

L.rv

t

A-2

SLAB & PLUMBING

#1

49

9 A

MO

DEL

JWC

JSL

09/17/19

LOT:

18

BLO

CK:

183

7

SUBD

IVIS

ION:

GULF

CO

VE S

PO

T L

OTS

AD

DRS:

547

3 H

OFFM

AN S

T

D.R

.H.

#:

57

95

00

022

GC

D J

OB #

11

048

1/4" = 1'-0"

SLAB PLUMBING

Page 4: A-1 · wh hb plan notes 1) verify all rough opening dimensions for all windows and doors 2) provide safety glazing within 24" from exit per florida building code r 308.4.2

WH

HB

PLAN NOTES

1) VERIFY ALL ROUGH OPENING DIMENSIONS FOR

ALL WINDOWS AND DOORS

2) PROVIDE SAFETY GLAZING WITHIN 24" FROM EXIT

PER FLORIDA BUILDING CODE R 308.4.2.

3) PROVIDE SAFETY GLAZING AT BATH/ SHOWER

PER FLORIDA BUILDING CODE R 308.4.5.

4) NON BEARING INTERIOR FRAME WALLS SHALL BE

FRAMED W/ WOOD OR METAL STUDS. SPACING SHALL

NOT EXCEED 24" O.C. (NON BEARING WALLS ONLY)

5) PROVIDE DEAD WOOD IN ATTIC FOR OVERHEAD

GARAGE DOOR HARDWARE

6) KITCHEN KNEE WALL TO BE FRAMED W/ TOP @

34 1/2" A.F.F.

7) INSTALL SMOOTH WALLS IN KITCHEN AND ALL

BATHROOM AREAS

8) WHERE DRYWALL CEILING IS APPLIED TO TRUSSES

@ 24" O.C. USE 5/8" DRYWALL OR 1/2" SAG

RESISTANT PER SEC. 702.3.5

9) THE GARAGE SHALL BE SEPARATED FROM THE

RESIDENCE & ATTIC BY NOT LESS THEN 1/2" GYPSUM

BOARD APPLIED TO THE GARAGE SIDE. GARAGES

BENEATH HABITABLE ROOMS SHALL BE SEPARATED

WITH NOT LESS THAN 5/8" TYPE "X" GYPSUM BOARD

OR EQUIVALENT. WHERE THE SEPARATIION IS A

FLOOR - CEILING ASSEMBLY, THE STRUCTURE

SUPPORTING THE SEPARTION SHALL ALSO BE

PROTECTED BY NOT LESS THAN 1/2" GYPSOM BOARD

OR EQUIVALENT

10) INSTALL 1 3/8" THICK SOLID WOOD DOOR BETWEEN

LIVING AND GARAGE PER FLORIDA BUILDING CODE

R302.1.5.

11) ALL WINDOWS INSTALLED 72" ABOVE GRADE MUST

COMPLY WITH R612.2 MIN 24" SILL HEIGHT OR

PROVIDED WITH AN APPROVED WINDOW FALL

PRVENTION DEVICE

12) ALL CLOSET SHELVES TO BE 12". ALL PANTRY &

LINEN TO BE (4)-16" SHELVES 18" 0.F.F. W/ 15"

INCREMENT.

13) ALL MECHANICAL AND ELECTRICAL EQUIPMENT TO BE

INSTALLED AT OR ABOVE FLOOD PLUS 1'-0" FREEBOARD.

DOOR HEADERS6'-8" BI-FOLD

6'-8" SWING

8'-0" SWING

HEADER HEIGHT 82" A.F.F.

82 1/2" A.F.F.

98 1/2" A.F.F.

HEADER HEIGHT

HEADER HEIGHT

CABINET BACKINGKITCHEN

MASTER BATH

GUEST BATH

LAUNDRY ROOM

UPPER TOP @ 84" BASE TOP @ 35"

UPPER

UPPER

UPPER TOP @ 84"

BASE TOP @ 35"

BASE TOP @ 31"

BASE

SQUARE FOOTAGELIVING AREA

GARAGE AREA

FRONT PORCH/ ENTRY AREA

1,499

385

16

TOTAL SQUARE FOOTAGE 1,900

2

2

3

2

4

2

2

2

2

2

7

2

2

B

B

B

D A 2

1

4'-5" 12'-9" 12'-2" 6'-0" 2'-8"

20

'-8

"4

'-4

"6

'-2

"5

'-4

"1

3'-6

"

9'-5" 3'-7" 2'-4" 3'-3" 5'-3" 3'-6" 2'-1" 8'-7"

38'-0"

55

'-0

"

7'-3

"4

'-0

"2

'-4

"3

'-7

"3

'-4

"7

'-0

"2

'-4

"7

'-0

"1

3'-2

"

18'-7" 5'-3" 2'-4" 1'-6" 1'-8" 8'-8"

2 CAR GARAGE

BEDROOM #4

MASTER SUITE GREAT ROOM

KITCHEN

BEDROOM #3

BEDROOM #2

VIN

YL

SHELV

ING

VIN

YL

SHELV

ING

VIN

YL

SHELV

ING

VINYL SHELVING

RANGE

REF. SPACE

DW

DBL SINK

5'-0

" TUB/S

HW

R

WASHER DRYER

3

10'-10" 2'-4" 5'-5" 5'-3" 2'-4" 11'-10"

8'-0" FLAT CEILING8'-0" FLAT CEILING

8'-0" FLAT CEILING

8'-0" FLAT CEILING

8'-0" FLAT CEILING

8'-0" FLAT CEILING

8'-0" FLAT CEILING

EGRESS

ESCAPE

EG

RES

S

EG

RES

S

EGRESS

MASTER

BATH

MIN. R-13 OR

BETTER INSULATION

BATH #2

FOYER

ENTRY

5'-0

"2

9'-0

"2

1'-0

"

55

'-0

"

8'-11" 5'-9"

38'-0"

19'-2" 4'-2" 14'-8"

5'-0

"2

4'-8

"2

5'-4

"

NOTE: THE GARGAE SHALL BE SEPERATED

FROM THE RESIDENCE AND ITS ATTIC AREA

BY NOT LESS THEN 1/2" GYPSUM BOARD

APPLIED TO THE GARAGE SIDE

SEE NOTE 9

NOTE: INSTALL 1-3/8" THICK

SOLID WOOD DOOR BETWEEN

LIVING AND GARAGE PER

R302.5.1

22" X 54"

ATTIC ACCESS

8'-0" FLAT CEILING

8'-0" FLAT CEILING

VERIFY LOCATION WITH

SITE PLAN, A/C NOT TO

ENCROACH EASEMENT

VIN

YL

SHELV

ING

1'-7" 16'-0" 1'-7"

UTILITY2

FIB

ERG

LASS

SHW

R 4 1

/2"

3'-6

"

O.H

CABSO.H CABS

LINEN

8'-0" FLAT

CEILING

2017 ACCESSIBLE

4'-0

"

44

6" WALL

6" WALL

A/H

3'-6

"2

'-6

"1

'-2

"4

'-4

"

BALL

CATCH

O.H

CABS

4'-7

1/2

"

34 1/2" KNEEWALL

INTERIOR DOOR SCHEDULE

MARK

1

2

3

DOOR WIDTH NOTES

P.K. = POCKET DOOR

B.F. = BI-FOLD DOOR

B.P. = BI-PASS DOOR

L.V. = LOUVERED DOOR

4

5

6

7

8

3'-0"

2'-8"

2'-6"

2'-4"

2'-0"

1'-8"

1'-6"

2'-11"

TOILET PAPER ROLL

2'-6"

1'-8"

TOWEL BAR

4'-0"

3'-2"

MIN.

4"

MIN.

4"

BATHROOM NOTES

ALL TUB DECKS @ 21" A.F.F

ALL BLOCKING TO BE PT IN SHOWERS

TOWEL BAR

TP TOILET PAPER

TB

FACE OF OUTSIDE WALL TO FACE OF STUD WALL FACE OF STUD TO FACE OF STUD

1/2"

3 1/2"

1/2"

FACE OF EXTERIOR WALL

1/2"

3 1/2"

1/2"TYPICAL DIMENSION STRING

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\G

ULF

CO

VE S

PO

T

LOTS\1

1048 L

OT 1

8 B

LK 1

837 1

499 A

L\REVIT

\11048 1

499 A

L.rv

t

A-3

FLOOR

#1

49

9 A

MO

DEL

JWC

JSL

09/17/19

LOT:

18

BLO

CK:

183

7

SUBD

IVIS

ION:

GULF

CO

VE S

PO

T L

OTS

AD

DRS:

547

3 H

OFFM

AN S

T

D.R

.H.

#:

57

95

00

022

GC

D J

OB #

11

048

1/4" = 1'-0"

FLOOR PLAN

DOOR SCHEDULETYPE

MARK DESCRIPTION MANUFACTURER HEIGHT WIDTH COUNT

1 3068 ENTRY DISTINCTION 6'-8" 3'-0" 1

2 2-3068 SL. GL. DR. DISTINCTION 6'-8" 6'-0" 1

3 16080 OHGD GARAGE 7'-0" 16'-0" 1

WINDOW SCHEDULE MARK DESCRIPTION HEIGHT WIDTH COUNT

A 2-25 SH 5'-3" 6'-4" 1

B 25 SH 5'-3" 3'-2" 3

D 35 SH 5'-3" 4'-6" 1

Page 5: A-1 · wh hb plan notes 1) verify all rough opening dimensions for all windows and doors 2) provide safety glazing within 24" from exit per florida building code r 308.4.2

WH

HB

HIP

RID

GE

VALLEY

2 CAR GARAGE 8'-0" FLAT CEILING

BEDROOM #3

BEDROOM #2

8'-0" FLAT CEILING

8'-0" FLAT CEILING

BATH #2 8'-0" FLAT CEILING

FOYER

ENTRY

8'-0" FLAT CEILING

BEDROOM #4

MASTER SUITE

MASTER BATH

8'-0" FLAT CEILING

8'-0" FLAT CEILING

8'-0" FLAT CEILING

KITCHEN8'-0" FLAT CEILING

GREAT ROOM8'-0" FLAT CEILING

UTILITY

8'-0" FLAT CEILING

HIP

HIP

HIP

HIP

ATTIC ACCESS

RID

GE

8'-0" FLAT

CEILING

6"

6" 2'-0" 3'-4"

2'-0" 5'-0" 2'-0"

6"

2'-0"

3'-4"

A/H

A/H

AIR HANDLER DETAIL

BEARING HEIGHT

= BEARING @ 8'-0"

MODEL 1499 A: ATTIC VENTILATION FBCR R806

SOFFIT ONLY (1/150) WITH ROOF VENTS (1/300)

AREAS (SQ. FT.) ATTIC VENTILATION REQUIRED ATTIC VENTILATION REQUIRED

MARK SOFFIT

2080.0 SQ. FT.

ATTIC AREA/150

7.71% -.-- SQ. FT. -.-%

COORDINATE VENTING REQUIREMENTS WITH ENERGY CALCULATIONS

(R.V.)

ROOF VENTS ARE NOT REQUIRED

32" BASE

22

-3/8

" BASE

LOMANCO 770-D

0.97 SQ. FT. FREE AIR

(NO ROOF VENTS)

13.87 SQ.FT.

"SOFFIT ONLY" QUALIFIES

SOFFIT MODEL

ACM QUAD 4, FULL VENT,

NARROW PATTERN,

8.15% FREE AIR FLOW

ATTIC

180.0 SQ. FT.

MIN AIR FLOW OF SOFFIT

ROOF VENT MODEL

1st STORY

REQ'D AIR FLOW

OF SOFFIT

QUAD 4 SOFFIT

HAS

8.15%

ATTIC AREA/300QUANTITY OF

ROOF VENTS

-

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\G

ULF

CO

VE S

PO

T

LOTS\1

1048 L

OT 1

8 B

LK 1

837 1

499 A

L\REVIT

\11048 1

499 A

L.rv

t

A-4

ROOF

#1

49

9 A

MO

DEL

JWC

JSL

09/17/19

LOT:

18

BLO

CK:

183

7

SUBD

IVIS

ION:

GULF

CO

VE S

PO

T L

OTS

AD

DRS:

547

3 H

OFFM

AN S

T

D.R

.H.

#:

57

95

00

022

GC

D J

OB #

11

048

1/4" = 1'-0"

ROOF PLAN

Page 6: A-1 · wh hb plan notes 1) verify all rough opening dimensions for all windows and doors 2) provide safety glazing within 24" from exit per florida building code r 308.4.2

WH

HB

TV

TV

T

PRE-WIRE FOR

FAN (TYP.)

PRE-WIRE FOR

FAN (TYP.)

PRE-WIRE FOR

FAN (TYP.)

PRE-WIRE FOR

FAN (TYP.)

PRE-WIRE FOR

FAN (TYP.)

SD

SCD

SD

SCD

SD

SCD

SD

GFI @ 42" A.F.F.

KEYLESS

DB

WP/GFI

NOTE: VERIFY

LOCATION OF GFI

PER DECO

BANDING

IN ATTIC

150 AMP PANELELEC METER

COACH

LIGHT

GFI @

42"

A.F.F.

COACH

LIGHT

W/P GFI

W/P

GFI

GFI

GFI GFI

GFI

UNDER CAB

STUB OUT FOR

GARAGE DOOR

OPENER

A/C DISCONNECT

GFI

EXH. FAN

EXH.

FAN

D

D

D

D

D

DD

D

K

D

ELECTRICAL HOMERUN

LOCATED IN LAUNDRY

ROOM

150 AMP ELECTRICAL RISER DIAGRAM

150 AMP

PANELM

(2) 4/0 AL & (1) 1/0 AL

OR CU EQUIVALENT

#6 CU MIN. TO (2) GROUND RODS,

AT LEAST 6FT APART.

POWER CO.

J

ELECTRICAL NOTES:

ALL OUTLETS IN WET AREAS AND ALL

ALL ELECTRIC, ELECTRICAL EQUIPMENT AND APPLIANCES TO BE SET AT

OR ABOVE BASE FLOOD ELEVATIONS PLUS 1'-0" FREEBOARD.

ARC-FAULT CIRCUIT-INTERRUPTERS AND TAMPER

RESISTANT RECEPTACLES SHALL BE INSTALLED

INSTALL PHONE AND T.V PER CONTRACT.

IN DWELLING UNITS PER N.E.C 210.12 AND 406.11

EXTERIOR OUTLETS TO BE GFI'S.

NOTE: NOT ALL SYMBOLS ARE USED FOR THIS

PROJECT.

SURFACE MOUNTED CEILING LIGHT

TELEVISION RECEPTION OUTLET

AC/DC SMOKE DETECTOR

TO BE INTERCONNECTED

WALL MTD. BRACKET LIGHT

DIMMER SWITCH

3 WAY SWITCH

SINGLE POLE SWITCH

TELEPHONE OUTLET

MOTION SENSOR SWITCH

A/C DISCONNECT

DUPLEX FLOOD LIGHT

TRACK MTD. LIGHTS

EXHAUST FAN

PUSH BUTTON (PB) / DOOR BELL (DB)

RECESSED LIGHT

1/2 SWITCHED DUPLEX OUTLET

DUPLEX RECEPTACLE OUTLET

4-PLEX RECEPTACLE OUTLET

220 V RECEPTACLE OUTLET

SINGLE RECEPTACLE OUTLET

DUPLEX RECEPTACLE AT ELEV. A.F.F.

ELECTRICAL PANEL

ELECTRICAL METER

120 V JUNCTION BOX

DUPLEX RECEPTACLE - ABOVE COUNTER

3

D

SD

TV

ELECTRICAL LEGEND

2' UNDER COUNTER LIGHT

4' FLUORESCENT LIGHT

INTERCOMIC

KP

KEYPAD

ANY RESIDENT HAVING A FOSSIL-BURNING

HEATER OR APPLIANCE, A FIREPLACE, OR

AN ATTACHED GARAGE SHALL HAVE AN

OPERATIONAL CARBON MONOXIDE ALARM

INSTALLED WITHIN 10 FEET OF EACH

ROOM USED FOR SLEEPING PERPOSES.

PER RULE 9B-3.04.72

SD (SMOKE DETECTOR)

SCD (CARBON MONOXIDE/ SMOKE

DETECTOR)

AFF

MS

INSTALL ALL ELECTRICAL PER NEC 2014

SCD

T

ELECTRICAL PLAN

150 AMP SERVICE

TAG

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

QUANTITY PRODUCT

(X)

(X)

(X)

(9)

(2)

(X)

(X)

(2)

(X)

(X)

(1)

(X)

(X)

(X)

(X)

(X)

(X)

(RECESSED CANS)

(VAPORS)

(PENDANT LIGHT

(10" MUSHROOMS)

(24" 3 LT)

(36" LT)

(NOT USED)

(COACH LIGHTS)

(J BOX)

(4' FLUORESCENT)

(2' FLUORESCENT)

(5LT CHANDELIER)

(3 LT )

(PENDANT/ NOOK)

(X)

(X)

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\G

ULF

CO

VE S

PO

T

LOTS\1

1048 L

OT 1

8 B

LK 1

837 1

499 A

L\REVIT

\11048 1

499 A

L.rv

t

A-5

ELECTRICAL

#1

49

9 A

MO

DEL

JWC

JSL

09/17/19

LOT:

18

BLO

CK:

183

7

SUBD

IVIS

ION:

GULF

CO

VE S

PO

T L

OTS

AD

DRS:

547

3 H

OFFM

AN S

T

D.R

.H.

#:

57

95

00

022

GC

D J

OB #

11

048

1/4" = 1'-0"

ELECTRICAL PLAN

Page 7: A-1 · wh hb plan notes 1) verify all rough opening dimensions for all windows and doors 2) provide safety glazing within 24" from exit per florida building code r 308.4.2

R310.2.1 MINMUM OPENING AREA- ALL EMERGENCY ESCAPE AND RESCUE

OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF

5.7 SQUARE FEET (0.530 m2).

EXCEPTION- GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET

CLEAR OPENING OF 5 SQUARE FEET (0.465 m2).

R310.2.1 MINMUM OPENING HEIGHT- THE MINIMUM NET CLEAR OPENING

HEIGHT SHALL BE 24 INCHES (610mm).

R310.2.1 MINMUM OPENING WIDTH- THE MINIMUM NET CLEAR OPENING

WIDTH SHALL BE 20 INCHES (508mm).

R310.1.1 OPERATIONAL CONSTRAINTS- EMERGENCY ESCAPE AND RESCUE

OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM

WITHOUT THE USE OF KEYS OR TOOLS.

R310.2.3 WINDOW WELLS- THE MINIMUM HORIZONTAL AREA OF THE WINDOW

WELL SHALL BE 9 SQUARE FEET (0.84 m2), WITH A MINIMUM HORIZONTAL

PROJECTION AND WIDTH OF 36 INCHES (914mm). THE AREA OF THE WINDOW

WELL SHALL ALLOW THE EMERGENCY ESCAPE AND RESCUE OPENING TO BE

FULLY OPENED.

MINIMUM EGRESS WINDOW DETAIL

1'-8" MIN.

2'-0

" M

IN.

3'-8

" M

AX.

FINISH FLOOR

5.7 SQ. FT.

CLEAR OPENING

R703.4 - WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT PROVIDED BY THE WINDOW

OR DOOR MANUFACTURER OR BY THE FLASHING MANUFACTURER, "PAN FLASHING" SHALL BE

INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL

BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF THE

EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE.

OPENINGS USING PAN FLASHING SHALL INCORPORATE FLASHING OF PROTECTION AT THE

HEAD AND SIDES.

"PAN FLASHING" IS A GENERIC TERM THAT USED TO REFER TO "METAL PAN FLASHING".

HOWEVER MANY MODERN MATERIALS HAVE BEEN DEVELOPED FOR THE SAME FUNCTION

SUCH AS:

- FLEXIBLE PEEL AND STICK FLASHING MEMBRANE

-FLUID APPLIED FLASHING

FOR SUCH PRODUCTS FOLLOW THE MANUFACTURER'S INSTALLATION REQUIREMENTS

FOR IN-DEPTH FLASHING INSTRUCTIONS, REFER TO THE FOLLOWING PUBLICATIONS:

FMA/AAMA 100

FMA/AAMA 200

FMA/WDMA 250

FMA/AAMA/WDMA 300

INSTALL "PAN" FLASHING AT THE WINDOW SILL

OPENING FOR WINDOW OR DOOR

WHERE "PAN" FLASHING IS

USED AT THE SILL, ALSO

INCORPORATE FLASHING

OR PROTECTION AT THE

HEAD AND SIDES

THE FLASHING INSTRUCTIONS FROM THE WINDOW/ DOOR MFR., OR THE FLASHING MFR.,

SHALL SUPERCEDE THIS DETAIL

PAN FLASHING PER R703.4

SCALE: N.T.S.

WALL SHEATHING

WITH HOUSE WRAP

OR ZIP SYSTEM

WALL SHEATHING

PAPER BACK

METAL LATH

MID WALL

WEEP SCREED

OVER FELT STRIP

MASONRY NAIL

6" WIDE FELT

MASONRY WALL

WOOD FRAMING EITHER

FLOOR TRUSS OR GABLE

END TRUSS

FELT AND

WEEP SCREED

WO

OD F

RAM

EM

ASO

NRY W

ALL

CORNER OF

BUILDING

CORNER BEAD

MITER OUT CORNER

BEAD AT MID WALL

WEEP SCREED

CAULK CENTER JOINT

IN MID WALL WEEP

SCREED 2" IN EA.

DIRECTION AT CORNER

CORNER OF

BUILDING

FULLY EMBED BACK FACE

OF WEEP SCREED IN

CAULK. LET OOZE OUT AT

CORNER AND SCREED 2"

MIN. WIDTH

WIRE LATH

WITH FELT

OVER FRAME

WALL

EXPANSION JOINT

EXPANSION JOINT OVER

WIRE LATH

DECO. TEXTURE FINISH

OVER WIRE LATH

WO

OD F

RAM

EM

ASO

NRY W

ALL

MASONRY WALLMASONRY WALL

DECO. TEXTURE FINISH

OVER WIRE LATH

EXPANSION JOINT

MASONRY WALL

EXPANSION JOINT

AMICO M-TYPE

CONTROL JOINT

AMCJM-780 OR

APPROVED EQUAL

OVER LATH (CUT

LATH BEHIND

CONTROL JOINT 1/4"

MIN. GAP) LOCATE

OVER STUD ONLY

AND PER NOTE 1

*

*NOTE 1:(AT WOOD

FRAME ONLY)

MAX OF 144 SQ. FT.

BETWEEN CONTROL

JOINTS. NOT GREATER

THAN 18'-0" O.C. MAX

AREA RATIO OF

CONTROL JOINTS-2-2/1 TO 1

WIRE THE CONTROL

JOINT TO LATH WITH

18 GA. GALVANIZED

WIRE AT 7' O.C. MAX.

WIRE LATH

OVER FELT

FELT PAPER

FRAME WALL

FELT STRIP

WIRE LATH OVER

MID WALL

WEEP SCREED

OVER FELT STRIPMID WALL

WEEP SCREED

OVER FELT STRIP

MITER OVER SCREED

FELT STRIP

OVER BLOCK WALL

BUILDING

MASONRY WALL

MID WALL WEEP SCREED DETAIL

WEEP SCREED DETAILINSTALL AT ALL EXTERIOR WALL LOCATIONS WHERE

WOOD STUD FRAMING IS ABOVE MASONRY WALLS.

GABLE WALL ROOF

EXTERIOR

ATTICATTICEXTERIOR

HOUSE WRAP

EXTERIOR PLYWOOD W/

RADIANT BARRIER ON

ATTIC SIDE

EXTERIOR STUD

WALL OR TRUSS

RADIANT BARRIER

GLUED TO PLYWOOD

TOP CHORD

RADIANT BARRIER: SCALE: N.T.S.

NOTE: EXTERIOR WALLS ADJACENT TO ATTIC SPACE, INCLUDING KNEEWALLS AND GABLE END WALLS, MUST HAVE

RADIANT BARRIER AND HOUSE WRAP.

RESIDENTIAL SPECIFICATIONS

1. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT

THE JOB SITE PRIOR TO COMMENCING WORK. THE CONTRACTOR SHALL

REPORT ALL DISCREPENCIES BETWEEN THE DRAWINGS AND EXISTING

CONDITIONS TO THE DESIGNER PRIOR TO COMMENCING WORK.

2. THE CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD INTO THE WORK

ALL INSERTS, ANCHORS, ANGLES, PLATES, OPENINGS, SLEEVES,

HANGERS, SLAB DEPRESSIONS AND PITCHES AS MAY BE REQUIRED TO

ATTACH AND ACCOMMODATE OTHER WORK.

3. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED

TO BE TYPICAL AND SHALL BE CONSTRUCTED TO APPLY TO ANY SIMILAR

SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT

DETAIL IS SHOWN.

4. SUBSURFACE SOIL CONDITION INFORMATION IS NOT AVAILABLE

FOUNDATIONS ARE DESIGNED FOR A SOIL BEARING CAPACITY OF 2,000

PSF. THE CONTRACTOR SHALL REPORT ANY DIFFERING CONDITIONS TO

THE DESIGNER PRIOR TO COMMENCING WORK.

5. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUCTION WITH JOB

SPECIFICATION AND HOUSE PLANS, MECHANICAL, ELECTRICAL,

PLUMBING, AND SITE DRAWINGS, CONSULT THESE DRAWINGS FOR

SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN ON

STRUCTURAL DRAWINGS.

6. ALL SPECIFIED FASTENERS MAY ONLY BE SUBSTITUTED IF APPROVED BY THE

ENGINEER IN WRITING, THE INSTALLATION OF THE FASTENERS

SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.

SIMPSON FASTENERS SPECIFIED MAY BE SUBSTITUTED WITH THE SAME QUANTITY

AND EQUIVALENT STRENGTH PRODUCT.

ALL BOLTS, NUTS, WASHERS, STRAPS AND FASTENERS INCLUDING

NAILS, SHALL BE HOT MOPED DIPPED GALVANIZED OR STAINLESS STEEL

CONTINUOUS ANCHORAGE SHALL BE PROVIDED BETWEEN ALL TRUSSES,

WALL SECTIONS, BEAMS, POSTS AND FOOTINGS WITH USE OF STRAPS

AND CONNECTORS AS SPECIFIED HEREIN.

7. TREATED WOOD REQUIREMENTS:-

ALL TREATED WOOD EXPOSED TO WEATHER SHALL BE PROTECTED, PRESSURE TREATED,

OR NATURALLY RESISTANT TO DECAY.

ALL WOOD TOUCHING MASONRY OR CONCRETE SHALL BE ISOLATED, OR

PRESSURE TREATED.

8. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER

THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILTY

TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO ENSURE SAFETY OF

THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE

NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS, OR TIE DOWNS.

9. CEILING DRYWALL INSTALLED WITHIN THE HOUSE TO TRUSSES SPACED 24" O.C.

SHALL BE 5/8" DRYWALL OR 1/2" SAG RESISTANT PER SEC. 702.3.5

10. LANAI CEILINGS & COVERED ENTRY CEILINGS

1X4 STRIPPING @ 16" O.C. FASTENED WITH 2-8d NAILS TO EACH TRUSS. 5/8"

EXTERIOR GYP. BOARD CEILING FASTENED WITH 8d NAILS OR 1-5/8" DRYWALL

SCREWS @ 6" O.C. EDGE AND FIELD.

GENERAL NOTES

1

ROOF SHEATHING

SHALL BE APA RATED SHEATHING, EXPOSURE 1, SPAN RATING 24/16 OR BETTER.

INSTALL PANELS WITH LONG DIMENSION PLACED PERPENDICULAR TO TRUSSES.

A 1/8" SPACE BETWEEN ADJACENT SHEETS SHALL BE MAINTAINED . INSTALL "H"

CLIPS AT UNSUPPORTED PANEL EDGES. THE ROOF SHEATHING SHALL BE NAILED

WITH

8d RING SHANK NAILS @ 4" O.C. EDGE AND 6" O.C. FIELD. ENSURE THAT ALL NAILS

PENETRATE THE TOP CHORD OF THE TRUSSES WITHOUT SPLITTING. RING SHANK

NAILS

PER R803.2.3.1 - 0.113" NOMINAL SHANK DIAMETER, RING DIAMETER OF 0.012"

OVER SHANK DIAMETER, 16 TO 20 RINGS PER INCH, 0.280" DIAMETER FULL

ROUND HEAD, 2" NAIL LENGTH.

FLASHING

FLASHING SHALL BE ALUMINUM, ALUMINUM ZINC COATED STEEL 0.0179" THICK,

26 GAUGE AZ50 ALUM ZINC, OR GALVANIZED STEEL 0.0179" THICK, 26 GAUGE

ZINC COATED G90. FLASHING SHALL BE INSTALLED IN ACCORDANCE WITH THE ZIP

SYSTEM ROOF SHEATHING MANUFACTURES PUBLISHED REQUIREMENTS. ALL

FLASHING AND INSTALLATION SHALL CONFORM TO SECTION R905.2.8 (1 TO 5).

DRIP EDGE

DRIP EDGE SHALL BE PROVIDED AT ALL EAVES AND GABLES OF SHINGLES ROOFS,

LAPPED A MINIMUM OF 3" @ JOINTS. THE OUTSIDE EDGE SHALL EXTEND A

MINIMUM

OF 1/2" BELOW SHEATHING AND THE INSIDE EDGE SHALL EXTEND BACK A MINMUM

OF 2". DRIP EDGE SHALL BE FASTENED AT NO MORE THAN 4" CENTERS. THERE

SHALL

BE A MINIMUM OF 4" WIDTH OF ROOF CEMENT INSTALLED OVER THE DRIP EDGE

FLANGE.

GENERAL ROOF ASSEMBLY

2

INSTALL PEEL AND STICK UNDERLAYMENT APPROVED FOR SINGLE

LAYER APPLICATION UNDER TILE ROOF.

THE INSTALLATION OF CLAY AND CONCRETE TILE SHALL COMPLY

WITH THE PROVISIONS OF R905.3 F.B.C.

MARKING: EACH ROOF TILE SHALL HAVE A PERMANENT

MANUFACTURER'S IDENTIFICATION MARK.

APPLICATION SPECIFICATIONS: THE TILE MANUFACTURER'S WRITTEN

APPLICATION SPECIFICATIONS SHALL BE AVAILABLE AND SHALL

INCLUDED BUT NOT BE LIMITED TO THE FOLLLOWING:

1. TILE PLACEMENT AND SPACING,

2. ATTACHMENT SYSTEM NECESSARY TO COMPLY

WITH CURRENT WIND CODE,

A. AMOUNT AND PLACEMENT OF MORTART

B. AMOUNT AND PLACEMENT OF ADHESIVE

C. TYPE, NUMBER, SIZE AND LENGTH OF FASTENERS AND CLIPS.

3. UNDERLAYMENT

4. SLOPE REQUIREMENT.

CLAY AND CONCRETE ROOF TILE SPECS

5

SHINGLES

15# FELT SHALL BE INSTALLED UNDER ASPHALT SHINGLES. ALL

ASPHALT SHINGLES SHALL HAVE SELD-SEALING STRIPS OR BE

INTERLOCKING AND COMPLY WITH ASTM D 225 OR D 3462, AND

SHALL BE SECURED TO THE ROOF WITH NO LESS THAN 6

FASTENERS PER SHINGLE STRIP, OR A MINIMUM OF 2 FASTENERS

PER SHNGLE TAB, AND SHALL IN NO CASSE BE FASTENED WITH

LESS FASTENERS THAN THAT REQUIRED BY THE MANUFACTURE.

INSTALLATION SHALL COMPLY WITH MANUFACTURES REQUIREMENTS

FOR INSTALLATION IN THE GIVEN FLORIDA WIND ZONE, AS

DETERMINED BY ASTM D 3161.

FASTENERS

FASTENERS FOR ASPHALT SHINGLES SHALL COMPLY WITH ASTM F

1667, AND SHALL BE MADE WITH GALVANIZED STEEL, STAINLESS

STEEL OR ALUMINUM WITH A MINIMUM SHANK SIZE OF 12 GAUGE

(0.105") WITH A MINIMUM 3/8" DIAMETER HEAD SHANK AND SHALL

BE A LENGTH TO PENTRATE THE SHEATHING

THE NAIL COMPONENT OF PLASTIC CAP NAILS SHALL MEET OR EXCEED

THE REQUIREMENTS OF ASTM A 641, CLASS 1, OR EQUAL, AND

SHALL BE CORROSION RESTITANT BY ELECTRO GALVANIZATION,

MECHANICAL GALVANIZATION, HOT DIPPED GALVANIZATION OR

SHALL BE MADE OF STAINLESS STEEL, NON-FERROUS METAL

ASPHALT SHINGLE ROOF SPEC'S

4

A.P.A. RATED STURDI-FLOOR, EXPOSURE 1, TONGUE & GROOVE EDGES

SPAN RATING 48/24 OR BETTER, GLUED AND NAILED

FLOOR SHEATHNG AT 2ND FLOOR

6

3

DOOR AND WINDOW ANCHORAGE

ANCHORAGE REQUIRMENTS- ALL PASS AND SLIDING GLASS DOORS AND ALL WINDOW

ASSEMBLIES SHALL BE ANCHORED TO THE MAIN WIND FORCE RESISTING SYSTEM IN A

MANNER SPECIFIED BY THE PUBLISHED MANUFACTURERS LITERATURE. THERE SHALL BE NO

SUBSTITUTION OF ALTERNATE FASTENINGS UNLESS PROVIDED BY THE MANUFACTURER AND

APPROVED BY THE BUILDING DESIGN ENGINEER.

MASONRY OPENING

WHERE WINDOW FRAME IS DESIGN TO FASTEN WITH SCREWS THROUGH THE FRAME AND INTO

THE MSANORY, THE BUCK MATERIAL IS SIMPLY A SPACER. THE BUCK MAY BE FASTENED WITH

THE T NAILS OR ANY SUITABLE FASTENER TO TACK IT INTO POSITION PRIOR TO WINDOW

INSTALLATION. FASTEN WINDOW FRAME PER MFR INSTRUCTIONS. A WINDOW FASTENER

SHALL PENETRATE MASONRY BY 2 1/4" MIN.

WHERE WINDOW FRAME IS DESIGNED TO FASTEN ONLY TO THE WOOD BUCK (IE, FLANGED

FRAME WITH WOOD SCREWS) THE BUCKS SHALL BE 2X WOOD WITH STRUCTURAL

FASTENING TO THE MASNORY WITH 1/4 X 3 3/4 MASONRY SCREWS @ 24" OC AND 6" FROM

EACH END.

WOOD FRAMED OPENING- ALL DOORS AND WINDOWS SHALL BE INSTALLED ACCORDING

TO THE PUBLISHED MANUFACTURERS LITERATURE OF THE ASSEMBLY BEING INSTALLED

TO THE ROUGH SUBSTRATE OPENING. SHIMS SHALL BE MADE OF MATERIALS CAPABLE

OF RESISTING THE APPLIED LOADS AND SHALL BE LOCATED NEAR EACH FRAME

FASTENER TO MINIMIZE DISTORTION OF THE FRAME AS THE FASTENERS ARE

TIGHTENED .

CONC. FOOTING

SEE FOUNDATION PLAN

FOR SIZE AND

REINFORCING.

1/2" DRYWALL W/

TEXTURED WALLS

1X2 P.T. FURRING STRIPS @ 24"

O.C. W/ INSULATION (MIN. R4.1)

WOOD BASE

4" CONC. SLAB ON 6 MIL.

VISQUEEN VAPOR BARRIER ON

MECHANICALLY COMPACTED FILL

@ 95%.

DECO. CEMENT

FINISH PER ASTM C-926

SILL SET IN MORTAR

SEE ENERGY CODE FORMS FOR

INSULATION R-VALUES

1X4 P.T. STRIP

ROOF SHEATHING PER SCHEDULE 2/S-1.

AND PER NOTES IN TABLE 3 ON A-6

WOOD TRUSSES @ 24" O.C. (TYPICAL.)

DESIGNED BY DELEGATED TRUSS

ENGINEER.

EMBEDDED STRAP AT EACH

TRUSS PER ROOF FRAMING PLAN.

FLASHING AND DRIP

EDGE PER NOTES IN

TABLE 2 ON A-6

2X6 MIN. SUB FASCIA

VENTED SOFFIT SHALL

MEET R703.1.2.1 SEE

TABLE 3 ON S-3

WINDOW, SEE SCHEDULE AND PLAN

DRYWALL CEILING PER

NOTE 9 IN TABLE 1 ON A-6

GRADE

TYPICAL WALL SECTION

TILE ROOF PER NOTE 6 ON A-6. OR

SHINGLE ROOF PER NOTE 5 ON A-6

PROVIDE VENTILATION

PER R806.1

PRECAST LINTEL SEE FRAMING PLAN

WINDOW BUCKS SEE TABLE 2 ON A-6

1X4 P.T. BUCK W. BED OF

CONTINUOUS CAULK UNDER

8X8 CONTINUOUS BOND

BEAM W/ 1 #5, GROUT

SOLID

SLOPE TO EXTERIOR

PRECAST CONCRETE SILL

PROVIDE TERMITE TREATMENT

WITH "BORA CARE".

D

W

12" M

IN. 4

" M

IN.

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\G

ULF

CO

VE S

PO

T

LOTS\1

1048 L

OT 1

8 B

LK 1

837 1

499 A

L\REVIT

\11048 1

499 A

L.rv

t

A-6

SECTIONS

#1

49

9 A

MO

DEL

JWC

JSL

09/17/19

LOT:

18

BLO

CK:

183

7

SUBD

IVIS

ION:

GULF

CO

VE S

PO

T L

OTS

AD

DRS:

547

3 H

OFFM

AN S

T

D.R

.H.

#:

57

95

00

022

GC

D J

OB #

11

048

Page 8: A-1 · wh hb plan notes 1) verify all rough opening dimensions for all windows and doors 2) provide safety glazing within 24" from exit per florida building code r 308.4.2

WH

HB

ELEV @ 0'-(-4")

2" SLO

PE

16'-0" X 7'-0" O.H. GARAGE DR.

6" X 12" RECESS

ELEV @ 0'-(-4")

PAVER BY

OTHERS

SET A/C PAD

ABOVE FLOOD

ELEVATION W/ 1'-0"

FREEBOARD PER

FBCR R322.2.1.

RUN CODUIT FOR

ELECTRIC AT ISLAND

PROVIDE 1/4" WATER

LINE @ REF. SPACE FOR

ICE MAKER

PAVER BY OTHERS

STANDARD SGD RECESS 1-1/2". IMPACT

GLASS SGD RECESS 2-1/2".

ELEV @ 0'-(-4")

INSTALL 1 3/8" THICK SOLID

WOOD DOOR BETWEEN LIVING

AND GARAGE PER FLORIDA

BUILDING CODE R302.5.1

5'-0

"5

0'-0

"

38'-0"

38'-0"

1'-7" 16'-0" 1'-7" 4'-2" 14'-8"

18'-11" 12'-0" 2'-6 1/2" 2'-6" 2'-0 1/2"

2'-2" 2'-10" 3'-0" 7'-3 1/2" 22'-8 1/2"

18'-6 1/2" 14'-9 1/2" 4'-8"

14'-8" 14'-6" 8'-10"

28'-10" 7'-0" 2'-2"

5'-0

"5

0'-0

"

21

'-0

1/2

"9

'-7

1/2

"3

'-0

1/2

"2

'-1

0"

13

'-5

1/2

"

13

'-2

"9

'-3

1/2

"1

0'-4

"5

'-1

1"

7'-3

1/2

"4

'-0

"

38'-0"

F3

F3

F3

F3

F3F3

F3

F6A

F6A

5'-0

TUB

F3 W

/ C

URB

FIB

ERG

LASS

SHW

R

5 1/2" 3'-3" 5 1/2"

#5 BAR IN GROUTED CELL, LAP

25" WITH #5 DOWEL OUT OF

SLAB WITH 7" HOOK INTO TOP

OF BOND BEAM 4'-0" O.C. MAX

8F8-1B SET AT GARAGE DOOR HEAD

HEIGHT, ADD COURSING AS REQUIRED

TO 8X8 BOND BEAM W/ 1#5, TOP @

8'-0" GROUT SOLID

AA

F3

SAWCUT SLAB PER

DETAIL 5/S-3

DBL SINK

DW

RANGE

REF. SPACE

DRYERWASHER

4" SLAB W/ 2,500 PSI CONC. W/ 6X6 #

10/10 W.W.M. REINFORCING OVER 6

MILL VISQUEEN BARRIER ON

MECHANICALLY COMPACTED FILL @ 95%.

THE FINISH FLOOR SLAB SHALL BE SET

ABOVE BASE FLOOD ELEVATION PER FEMA

FLOOD MAP PLUS 1'-0" FREEBOARD PER

FBCR R322.2.1. SEE SITE PLAN BY OTHERS

ELEV. @ 0'-0"

LOWEST POINT OF GARAGE SHALL BE SET ABOVE

BASE FLOOD ELEVATION PER FEMA FLOOD MAP

SET W/H ABOVE FLOOD

W/ 1'-0" FREEBOARD

PER FBCR R322.2.1

11

S-3

PROVIDE TERMITE

TREATMENT WITH

"BORA CARE"

FOUNDATION PLAN

PLAN NOTES:

1. TOP OF GROUND FLOOR SLAB DATUM ELEVATION 0'-0"

2. "F#" DENOTES CONTINUOUS WALL FOOTING TYPE PER SCHEDULE THIS SHEET.

3. # DENOTES PAD FOOTING AT CONCENTRATED LOADS PER SCHEDULE THIS SHEET.

4. PROVIDE #5 VERTICAL REINFORCING AT DOT LOCATIONS SHOWN ON PLAN FROM FOOTING

TO BOND BEAM.

5. ALL DIMENSIONS ARE TO OUTSIDE FACE OF MASONRY WALLS. SOME SLAB EDGES MAY

EXTEND BEYOND FACE OF WALL.

6. FOR DIMENSIONS OF ROUGH OPENINGS IN MASONRY WALLS, COORDINATE WITH WINDOW/

DOOR SUPPLIER.

7. PROVIDE PRESSURE TREATED BUCKS AT WINDOWS/ DOORS PER DETAIL 7/S-3.

SCALE: 3/16" = 1'-0"TYPE LENGTH WIDTH DEPTH

CONT. 1'-4"

1'-8"

1'-0"

1'-4"

1'-4"

F1

F2

F3

F4

F5

1'-8"

1'-0"

1'-0"

2-#5

SHAPE

WALL FOOTING SCHEDULE

US

ED BOTTOM

REINFORCING

F6

F6A

TE

CONT.

CONT.

CONT.

CONT.

CONT.

CONT.

CONT.

1'-4"

0'-8"

0'-8" 0'-8"

0'-8"

1'-8"

0'-10"

0'-8"

2-#5

2-#5

2-#5

2-#5

2-#5

1-#5

1-#5

ADD CURB TO

GARAGE, SEE

DETAIL

PROVIDE CORNER BARS PER 6/S-3

TYPE LENGTH WIDTH DEPTH

2'-6" 2'-6"

3'-0"3'-0"

3'-6"3'-6"

4'-0"4'-0"

5'-0"5'-0"

A

B

C

D

E

1'-0"

1'-0"

1'-0"

1'-2"

1'-2"

3-#5 3-#5

4-#5 4-#5

4-#5 4-#5

5-#5 5-#5

6-#5 6-#5

-

-

-

-

-

REMARKSLONG WAY SHORT WAY

BOTTOM REINF.

PAD FOOTING SCHEDULE

US

ED

1'-8

"

FIN. GRADE

#5 DOWEL WITH

7" HOOK, EMBED

5" MIN.

2 #5 CONT. W/

3" CLEAR COVER.

1'-0"

1'-0"

MIN

.

2'-1

"

1'-8

"

FIN. GRADE

#5 DOWEL WITH

7" HOOK, EMBED

5" MIN. BELOW

GARAGE FLOOR

2 #5 CONT. W/

3" CLEAR COVER.1'-0"

1'-0"

MIN

.

7 5/8"

.

VARIES WITH

SLOPE OF FLOOR

CURB IS OPTIONAL & NOT INCLUDED

IN FOOTING DIMENSIONS

2'-1

"

8"X8" CONC. RIBBON

W/ 1 #5 ROD CONT.

1" 3"

8"

8"

PAVERSMORTAR

3" CLEAR COVER1 #5

8"

8"

6"

10

"

GRADE

4" CONC. SLAB

(2) #5 RODS

CONT.

1'-0"

RECESS

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\G

ULF

CO

VE S

PO

T

LOTS\1

1048 L

OT 1

8 B

LK 1

837 1

499 A

L\REVIT

\11048 1

499 A

L.rv

t

S-1

FOUNDATION PLAN

#1

49

9 A

MO

DEL

JWC

JSL

09/17/19

LOT:

18

BLO

CK:

183

7

SUBD

IVIS

ION:

GULF

CO

VE S

PO

T L

OTS

AD

DRS:

547

3 H

OFFM

AN S

T

D.R

.H.

#:

57

95

00

022

GC

D J

OB #

11

048

1/4" = 1'-0"

FOUNDATION

1/2" = 1'-0"

"F3" FOOTING

1/2" = 1'-0"

"F3" WITH CURB AT GARAGE

1/2" = 1'-0"

"P" PAVERS DETAIL ENTRY/ LANAI1

1/2" = 1'-0"

"F6A" STEP DOWN

1/2" = 1'-0"

GARAGE DOOR RECESS

Page 9: A-1 · wh hb plan notes 1) verify all rough opening dimensions for all windows and doors 2) provide safety glazing within 24" from exit per florida building code r 308.4.2

WH

A5

J3

J3

A2

J3

J1

J1J1

CJ1

0

A4

J5

J5 J5

A1

A6

A3

CJ1

0

J3

A5

J3

J3

A2

J1

J1

J1

J5

A4

J5

J5

A6

A3

A1

J3

J1

J5

CJ1

0

J3

J1

J5

CJ1

0

A7

EJ7

EJ7EJ7 EJ7A

VG1

V1

V2

HB

HIP

RID

GE

VALLEY

2 CAR GARAGE 8'-0" FLAT CEILING

BEDROOM #3

BEDROOM #2

8'-0" FLAT CEILING

8'-0" FLAT CEILING

BATH #2 8'-0" FLAT CEILING

FOYER

ENTRY

8'-0" FLAT CEILING

BEDROOM #4

MASTER SUITE

MASTER BATH

8'-0" FLAT CEILING

8'-0" FLAT CEILING

8'-0" FLAT CEILING

KITCHEN8'-0" FLAT CEILING

GREAT ROOM8'-0" FLAT CEILING

UTILITY8'-0" FLAT CEILING

HIP H

IP

HIP

THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE & ATTIC BY

NOT LESS THEN 1/2" GYPSUM BOARD APPLIED TO THE GARAGE SIDE.

GARAGES BENATH HABITABLE ROOM SHALL BE SEPARATED WITH NOT

LESS THAN 5/8" TYPE "X" GYPSUM BOARD OR EQUIVALENT. WHERE

THE SEPARATION IS A FLOOR- CEILING ASSEMBLY THE STRUCTURE

SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT

LESS THAN 1/2" GYPSUM BOARD OR EQUIVALENT

HIP

8F8-0B

8F8-0B

8F8

-0B

8F8

-0B

8F8-0B 8F8-0B 8F8-0B

RID

GE

1-HTA20

@ A1

8F8-1B SET AT GARAGE DOOR HEAD

HEIGHT, ADD COURSING AS REQUIRED

TO 8X8 BOND BEAM W/ 1#5, TOP @

8'-0" GROUT SOLID

1-HTA20

@ A1

8F8-1B

(+33.5 -36.3)

(+33.5 -36.3)

(+28.2 -31.5)

(+3

3.5

-3

6.3

)

(+33.5 -44.8(+33.5 -36.3)(+33.5 -44.8)

(+3

3.5

-3

6.3

)

WHERE ROOF SHEATHING CONTACTS ONLYT

THE EDGE OF ROOF TRUSSES, INSTALL

BEVELLED BLOCKING PER DETAILS THIS

SHEET (DR HORTON COMPANY

REQUIREMENT)

(+33.5 -36.3) WIND

PRESSURES PER ASCE7-10,

160 MPH, EXPOSURE C AND

CONVERTED TO ALLOWABLE

STRESS DESIGN PRESSURES

USING 0.6W LOAD FACTOR.

(Vasd=124 MPH, RISK CAT II,

ENCLOSED, kd=0.85, H-15')

#5 BAR IN GROUTED CELL,

WITH 7" HOOK INTO TOP

OF BOND BEAM

EMBED HTA16-18 AT ALL

TRUSSES, EXCEPT AS

NOTED AT GIRDERS

8X8 CONTINUOUS

MASONRY BOND BEAM AT

TOP OF WALL W/ 1 #5

BAR. PROVIDE CORNER

BARS PER 8/S-3

1-HTA20

@ A1

1-HTA20

@ A1

11

S-3

CORNER BARS IN

BOND BEAM PER

DETAIL 8/S-3OUTLOOKERS PER

DETAIL 12/S-3

BOT @ 7'-4"

EGRESS

EG

RES

S

EG

RES

S

EGRESS

GABLE BRACE

NOT REQUIRED

TRUSS STRAPPING TO MASONRY

MAX TRUSS UPLIFT

@ 24" OC (LBS)CONNECTOR FASTENER

1615

1870

2430 (1 PLY)

2800 (2 PLY)

3170 (2 PLY)

5005

(1) HTA16-18

(1) HTA20

(2)HTA16- 18

(2)HTA16 -18

(2) HTA20

HTT45

10-10dx1/2", EMBED 4"

10-10dx1/2", EMBED 4"

10-10dx1/2", EMBED 4"

10-10dx1/2", EMBED 4"

10-10dx 1/2", EMBED 4"

5/8"ø ATR, EPOXY 12"

INSTALL HTA

16-18 AT ALL

TRUSSES TO

1615 lb UPLIFT.

FOR HIGHER

UPLIFTS, SEE

NOTES ON PLAN.

NOTES:

1. PROVIDE A STRAP FROM THE ABOVE LIST AT EACH ROOF TRUSS BEARING

POINT, BASED ON THE TRUSS UPLIFT VALUES IN THE SIGNED AND SEALED

TRUSS DESIGN PACKAGE AND SUITABLE FOR THE GEOMETRY. EMBED STRAP

ON -C/L OF WALL.

2. CONNECTORS ARE USP STRUCTURAL CONNECTORS. ALL CONNECTORS

SHALL BE INSTALLED IN STRICT ACCORDANCE WITH USP PRINTED

INSTUCTIONS. SUBSTITUTIONS MUST BE APPROVED IN WRITING BY THE

ENGINEER OF RECORD.

3. WHERE EMBEDDED STRAPS ARE MISSING, OR MIS-LOCATED, INSTALL

RETROFIT STRAP PER 2/S-4.

4. ' ATR' = ALLTHREAD. DRILL AND EPOXY WITH USP EPOXY PER MFR.

INSTRUCTIONS. REV2

WALL ABOVE WITH BOND

BEAM AT TOP

#5 VERTICAL, ABOVE

LINTEL ONLY WHERE

NOTED ON PLAN

'1B' DENOTES 1#5 BOTTOM

WITH 7" HOOK EACH END OR

EXTEND 24" BEYOND OPENING.

'0B' DENOTES "NO REBAR"

8" PRECAST LINTEL

GR

OU

T S

OLID

8F8-1B

8F8-0B

PRECAST LINTEL SCHEDULE

AT SWING DOORS, USE 2" RECESS STYLE

LINTEL IF NEEDED FOR ROUGH OPENING.

LINTELS BEAR 4" MIN. EACH END

PLAN NOTES:

1. ROOF TRUSS BEARING 8'-0", SEE LEGEND.

2. ROOF FRAMING SHALL BE WOOD TRUSSES DESIGNED

BYA DELEGATED TRUSS ENGINEER PER DESIGN

CRITERIA ON SHEET S-3.

3. PROVIDE STRAPPING AT TRUSSES PER NOTES ON THIS

SHEET.

4. FOR NAILING OF ROOF AND FLOOR DECK, SEE 1 AND 2

ON S-3.

5. 8F8-1B etc., DENOTES PRECAST LINTEL ABOVE

DOOR/WINDOW OPENING PER SCHEDULE THIS SHEET.

6. AT TRUSS BEARING, PROVIDE 8x8 MASONRY BOND

BEAM W/ 1 #5 CONTINUOUS, SEE DETAIL 11/S-3.

BEARING HEIGHT

= BEARING @ 8'-0"

ROOF SHEATHING

8d RING SHANK @

6" O.C.

16d NAILS

@ 8" O.C.

2" X () BLOCKING W/

BEVEL CUT TOP

ROOF TRUSS

BEVELLED BLOCKING DETAIL

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\G

ULF

CO

VE S

PO

T

LOTS\1

1048 L

OT 1

8 B

LK 1

837 1

499 A

L\REVIT

\11048 1

499 A

L.rv

t

S-2

ROOF FRAMING PLAN

#1

49

9 A

MO

DEL

JWC

JSL

09/17/19

LOT:

18

BLO

CK:

183

7

SUBD

IVIS

ION:

GULF

CO

VE S

PO

T L

OTS

AD

DRS:

547

3 H

OFFM

AN S

T

D.R

.H.

#:

57

95

00

022

GC

D J

OB #

11

048

1/4" = 1'-0"

ROOF FRAMING PLAN

TRUSS BEARING CONDITIONS AND

STRAPPING IS BASED ON TRUSS LAYOUT

PREPARED BY SCOSTA JOB# 44116

DATED: 05/24/18 REVISED: 9/15/18

Page 10: A-1 · wh hb plan notes 1) verify all rough opening dimensions for all windows and doors 2) provide safety glazing within 24" from exit per florida building code r 308.4.2

” ” ”

AutoCAD SHX Text
2
AutoCAD SHX Text
6
AutoCAD SHX Text
10
AutoCAD SHX Text
DESIGN CRITERIA: DESIGN IN ACCORDANCE WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE 6th EDITION (2017) RESIDENTIAL 1. FLOOR & ROOF UNIFORM LOADS: ROOF: LIVE TOP CHORD 20 PSF LIVE BOTTOM CHORD 10 PSF (NON-CONCURRENT w/ TCLL) SHINGLE/METAL ROOFING DEAD LOAD 15 PSF TOTAL MINIMUM DEAD LOAD FOR WIND: TC 5 PSF, BC 5 PSF DEFLECTION CRITERIA: ROOF L/240 LIVE, L/180 TOTAL 2. WIND LOADS: WIND DESIGN PER, ASCE7-10 BASIC WIND SPEED (ASCE7-10) 160 MPH NOMINAL WIND SPEED (Vasd TABLE R301.2.1.3) 124 MPH BUILDING CATEGORY II IMPORTANCE FACTOR 1.00 EXPOSURE C MEAN ROOF HEIGHT = 15 FT ROOF PITCH 5/12 ENCLOSURE CLASS. ENCLOSED INTERNAL PRES. COEFF. +/- 0.18 WINDOW/DOOR DESIGN WIND PRESSURE, SEE TABLE IN DETAIL 3. SOFFITS - PER R703.1.2.1, ALL SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED IN TABLE R301.2(2) FOR WALLS. 3. REINFORCED CONCRETE: DESIGN AS PER ACI 318-14 REQUIRED COMPRESSIVE STRENGTH AT 28 DAYS: SLAB ON GRADE f'c = 2500 PSI 3~8" MINIMUM THICKNESS REINFORCED WITH 6x6 w1.4xw1.4 WWF OR FIBERMESH. CONVENTIONAL SHALLOW FOOTINGS f'c = 2500 PSI BEAMS AND COLUMNS f'c = 3000 PSI ALL OTHER CONCRETE (U.N.O.) f'c = 3000 PSI UNLESS OTHERWISE SHOWN ON DRAWINGS, MINIMUM CONCRETE COVER FOR REINFORCING SHALL BE AS FOLLOWS: FOOTINGS 3" SLAB ON GRADE CENTERED BEAMS 1~8" COLUMNS 1~8" ALL REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE WITH THE TYPICAL BENDING DIAGRAMS AND PLACING DETAILS OF ACI STANDARDS AND SPECIFICATIONS. ALL REINFORCING STEEL SHALL BE HELD SECURELY IN POSITION WITH STANDARD ACCESSORIES DURING PLACING OF CONCRETE. REINFORCING STEEL - ASTM A615 GRADE 40 FOR #3 GRADE 60 FOR #4 TO #11 WELDED WIRE FABRIC - ASTM A185 SPLICES IN REINFORCING, SHALL BE 40 BAR DIAMETERS. NON-CONTACT LAP SPLICES MAY BE USED PROVIDED REINFORCING IS NOT SPACED MORE THAN 5" APART FOR #5 BARS. FORMWORK AND SHORING SHALL REMAIN IN PLACE UNTIL CONCRETE HAS REACHED AT LEAST 2/3 OF THE REQUIRED 28 DAY STRENGTH. 4. REINFORCED MASONRY: DESIGN PER ACI 530-13 REQUIRED COMPRESSIVE STRENGTHS: MASONRY WALLS f'm = 1500 PSI REINFORCING STEEL - ASTM A615 GRADE 60. SPLICES IN REINFORCING, SHALL BE 48 BAR DIAMETERS. ALL CONCRETE MASONRY UNITS SHALL BE COMPOSED OF ASTM C90, GRADE N-1 HOLLOW CONCRETE MASONRY UNITS WITH TYPE 'S' MORTAR. GROUT ALL CELLS CONTAINING VERTICAL REINFORCEMENT WITH 3000 PSI PEA ROCK CONCRETE GROUT. ALL CELLS BELOW FINISHED GRADE SHALL BE GROUTED SOLID. ALL EXTERIOR WALLS SHALL BE REINFORCED FULL HEIGHT AT DOT LOCATIONS ON PLAN. 5. DELEGATED-ENGINEERED WOOD ROOF TRUSSES: ALL WOOD ROOF TRUSSES SHALL BE DESIGNED BY A DELEGATED TRUSS ENGINEER PER RULE 61G15-31.003 OF THE FLORIDA ADMINISTRATIVE CODE. ALL TRUSSES SHALL HAVE TEMPORARY BRACING PER "COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLING AND BRACING METAL PLATE CONNECTED WOOD TRUSSES, HIB-91." FOR OTHER BRACING REQUIREMENTS, NOTIFY ENGINEER. PROVIDE PERMANENT BRACING PER TRUSS MFR. SHOP DRAWINGS. IF PERMANENT BRACING IS NOT SPECIFIED, CONTACT ENGINEER. 6. FOUNDATION: CONVENTIONAL SHALLOW CONCRETE FOOTINGS SOIL BEARING CAPACITY 2000 PSF THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE SUITABILITY OF THE SOIL CONDITIONS FOR THE INTENDED STRUCTURE AND ASSUMED SOIL BEARING CAPACITY. IT IS RECOMMENDED THAT A GEOTECHNICAL FIRM BE HIRED TO PERFORM A SITE EVALUATION. 7. DIMENSIONS: VERIFY ALL DIMENSIONS WITH HOUSE PLANS. SEE HOUSE PLANS, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR EMBEDS, OPENINGS, SLEEVES, ETC. WHICH ARE NOT SHOWN ON STRUCTURAL DRAWINGS. 8. MEANS AND METHODS: THE STRUCTURAL ENGINEER SHALL NOT HAVE CONTROL OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, OR SEQUENCES TEMPORARY BRACING, SHORING, GUYING OR OTHER MEANS TO SUPPORT STRUCTURAL ELEMENTS IN PLACE DURING CONSTRUCTION. FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, OR ANY OTHER PERSONS PERFORMING THE WORK OR FOR THE FAILURE OF ANY OF THEM TO CONSTRUCT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 9. SHOP DRAWINGS: SHOP DRAWINGS SHALL BE PREPARED AND SUBMITTED TO THE ENGINEER FOR REVIEW FOR ALL STRUCTURAL ELEMENTS UTILIZING PREFABRICATED COMPONENTS. ONE SET OF SIGNED & SEALED TRUSS ENGINEERING SHALL BE DELIVERED TO THE ENGINEER OF RECORD FOR THE STRUCTURE PER FLORIDA ADMINISTRATIVE CODE 61G15-30.005 AND 61G15-31.003.
AutoCAD SHX Text
8
AutoCAD SHX Text
7
AutoCAD SHX Text
1
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
NOTES: 1) PROVIDE SAWCUTS TO CREATE APPROXIMATE 20' X 20' MAXIMUM SQUARES. 2) SAWCUT CONCRETE SLAB WITHIN 4 TO 12 HOURS OF CONCRETE PLACEMENT.
AutoCAD SHX Text
~w" DEEP SAWCUT w/ ELASTOMERIC SEALANT
AutoCAD SHX Text
SLAB ON GRADE, SEE PLAN
AutoCAD SHX Text
%%USLAB SAWCUT DETAIL
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
%%UCORNER BARS
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
FINISHED GRADE, SEE SITE PLAN
AutoCAD SHX Text
3" CLEAR COVER TO REINFORCING
AutoCAD SHX Text
EMBED DOWELS 5" WITH 10" STD HOOK
AutoCAD SHX Text
MONOLITHIC FOOTING, SEE PLAN
AutoCAD SHX Text
DOWEL TO MATCH WALL REINFORCING, LAP 25"
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
%%UMONOLITHIC FOOTINGS
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
%%UINTERIOR
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
%%UEDGE
AutoCAD SHX Text
%%UGARAGE
AutoCAD SHX Text
D
AutoCAD SHX Text
%%USTEPDOWN
AutoCAD SHX Text
C
AutoCAD SHX Text
%%UFOOTING
AutoCAD SHX Text
%%UPLAN VIEW
AutoCAD SHX Text
FOOTING REINF., SEE PLAN
AutoCAD SHX Text
LAP CORNER BARS 40 BAR DIAMETERS
AutoCAD SHX Text
CONCRETE FOOTING, SEE PLAN
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
%%UROOF DECK NAILING PATTERN
AutoCAD SHX Text
%%UTYPICAL
AutoCAD SHX Text
%%UPLAN
AutoCAD SHX Text
%%UHOUSE
AutoCAD SHX Text
8d RING SHANK NAILS 6" O.C. EDGE AND 6" OC FIELD. ENSURE THAT ALL NAILS PENETRATE THE TOP CHORD OF THE TRUSS WITHOUT SPLITTING.
AutoCAD SHX Text
#5 CORNER BAR, 25"x25"
AutoCAD SHX Text
MASONRY BOND BEAM, TYPICAL
AutoCAD SHX Text
%%UCORNER
AutoCAD SHX Text
%%UCORNER BAR DETAIL IN BOND BEAMS
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
#5 CORNER BAR, 25"x25"
AutoCAD SHX Text
MASONRY BOND BEAM, TYPICAL
AutoCAD SHX Text
%%UINTERSECTION
AutoCAD SHX Text
11
AutoCAD SHX Text
NOTE: THIS BUCK FASTENING DETAIL IS INTENDED FOR FLANGED WINDOW/DOOR PRODUCTS THAT FASTEN THRU THE FLANGE WITH WOOD SCREWS TO THE BUCK. FOR WINDOW/DOOR PRODUCTS THAT DO NOT HAVE A FLANGE AND FASTEN INSTEAD OUTWARD THRU THE FRAME, USE MASONRY SCREWS PER MFR. THAT ARE LONG ENOUGH TO PENETRATE 2-1/4" INTO THE MASONRY. IN THIS CASE, THE BUCK MATERIAL IS SIMPLY A SPACER AND MAY BE 1x4 OR 1x6 OR OMITTED ENTIRELY AND THE SPACER MAY BE TACKED IN PLACE WITH MASONRY NAILS OR PINS.
AutoCAD SHX Text
%%UBUCK FASTENING
AutoCAD SHX Text
8" CMU WALLS
AutoCAD SHX Text
~4"x3~w" TAPCON @ 24" OC, 3 SCREWS MIN. (SEE NOTE)
AutoCAD SHX Text
2x4 or 2x6 P.T. BUCK @ FLANGED WINDOWS (SEE NOTE)
AutoCAD SHX Text
8" CMU, SEE PLAN FOR REINFORCING
AutoCAD SHX Text
%%UGARAGE DOOR
AutoCAD SHX Text
~8"~D EXPANSION BOLT, 4" MIN. EMBEDMENT, SPACE 24" OC AND 12" FROM TOP & BOT.
AutoCAD SHX Text
2x8 OR 2x6 P.T. SYP#2
AutoCAD SHX Text
2x2x~2" WASHER
AutoCAD SHX Text
3
AutoCAD SHX Text
5
AutoCAD SHX Text
+33.5 -36.3
AutoCAD SHX Text
(Vasd=124 MPH, RISK CAT II, ENCLOSED, kd=0.85, h=15')
AutoCAD SHX Text
INTERIOR ZONE 4
AutoCAD SHX Text
+33.5 -36.3
AutoCAD SHX Text
(SEE PLAN FOR OTHER SPECIFIC PRESSURES)
AutoCAD SHX Text
1) TABLE MAY BE USED FOR ANY SIZE WINDOW OR DOOR IN EACH TYPE. 2) USE "INTERIOR ZONE 4" PRESSURES UNLESS WINDOW OR DOOR IS LOCATED WITHIN THE "END ZONE 5" (SEE DIAGRAM BELOW), THEN USE THE HIGHER PRESSURES UNDER THE "END ZONE 5" COLUMN. 3) ALL GLASS / GLAZING SHALL BE IMPACT RATED OR USE IMPACT RATED SHUTTERS. 4) SUBMIT PRODUCT APPROVALS TO THE BUILDING DEPARTMENT AS REQUIRED BY THE LOCAL JURISDICTION. 5) MANUFACTURED SOFFIT PRODUCTS SHALL BE INSTALLED PER MFR ENGINEERING SPEC SHEETS.
AutoCAD SHX Text
WINDOW/DOOR/SOFFIT DESIGN WIND PRESSURES
AutoCAD SHX Text
TO ALLOWABLE STRESS DESIGN PRESSURES USING 0.6W LOAD FACTOR.
AutoCAD SHX Text
WIND PRESSURES PER ASCE7-10, 160 MPH, EXPOSURE C, AND CONVERTED
AutoCAD SHX Text
* ON IRREGULAR SHAPED BUILDINGS, THERE IS NO GUIDANCE IN THE CODE FOR HOW FAR A CORNER MUST PROTRUDE FROM THE MAIN BUILDING TO BE CONSIDERED 'ZONE 5'. WE HAVE CHOSEN >15'. THIS IS SUBJECT TO JUDGEMENT CALL BY THE AUTHORITY HAVING JURISDICTION.
AutoCAD SHX Text
IN ZONE 5, MANUFACTURED SOFFIT PRODUCTS MAY REQUIRE ADDITIONAL BATTONS OR FASTENING PER MFR ENGINEERING SPEC SHEETS TO MEET THE PRESSURE REQUIREMENTS.
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
%%UPLAN
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
%%UHOUSE
AutoCAD SHX Text
%%UTYPICAL
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
8' OR 9' GARAGE DOORS
AutoCAD SHX Text
TYPICAL WINDOWS & DOORS
AutoCAD SHX Text
16' OR 18' GARAGE DOORS
AutoCAD SHX Text
SOFFIT
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
END ZONE 5 PRESSURES OCCUR AT "PRIMARY" OUTSIDE CORNERS OF BUILDING (BOLD LINES)
AutoCAD SHX Text
FACE OF WALL
AutoCAD SHX Text
MEASURED FROM
AutoCAD SHX Text
ZONE
AutoCAD SHX Text
4
AutoCAD SHX Text
INTERIOR ZONE 4 PRESSURES
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5'-0"
AutoCAD SHX Text
WIDTH = ______
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
+33.5 -44.8
AutoCAD SHX Text
END ZONE 5
AutoCAD SHX Text
+33.5 -44.8
AutoCAD SHX Text
+29.4 -33.3
AutoCAD SHX Text
+28.2 -31.5
AutoCAD SHX Text
END
AutoCAD SHX Text
At Exterior Stud Walls and Gable Ends with Wall Sheathing, apply plaster over metal lath over water resistive barrier as follows: Plaster R703.7.2: 3-coat 7/8" thick portland cement based : 3-coat 7/8" thick portland cement based thick portland cement based plaster per ASTM C926. Metal Lath R703.7.1: Self furring paper backed 2.5lb diamond : Self furring paper backed 2.5lb diamond mesh metal lath per ASTM C847, G60 galvanized, fastened per ASTM C1063 with 1-1/2” long, 11 gage nails long, 11 gage nails with 7/16” head (roofing head (roofing nails) at 7” oc, or 1-1/2” long, 16 gage staples at 6” oc, into oc, or 1-1/2” long, 16 gage staples at 6” oc, into long, 16 gage staples at 6” oc, into oc, into the framing members (ie, the nails or staples must align with and penetrate 3/4” into the framing studs). into the framing studs). Water Resistive Barrier (WRB) R703.7.3: Water-resistive : Water-resistive vapor-permeable barrier with a performance at least equivalent to 2 layers of Grade D paper. The individual layers shall be installed independently. An approved house wrap may be used for the 1st layer and metal lath with approved paper backing may be the 2nd layer (Note: ZIP wall sheathing with seam tape qualifies as the first layer).
AutoCAD SHX Text
%%URETROFIT UPLIFT CONNECTOR SCHEDULE
AutoCAD SHX Text
NOTES: 1) WHERE EMBEDDED STRAP IS MISSING OR MIS-LOCATED, PROVIDE A STRAP FROM THE ABOVE LIST AT EACH ROOF TRUSS BEARING POINT, BASED ON THE TRUSS UPLIFT VALUES IN THE SIGNED AND SEALED TRUSS DESIGN PACKAGE. 2) CONNECTORS ARE USP. ALL CONNECTORS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH USP PRINTED INSTRUCTIONS. 3) CONCRETE SCREW SHALL BE WEDGE-BOLT+, TITEN, TAPCON OR EQUIVALENT.
AutoCAD SHX Text
1-HTWM16 or 20
AutoCAD SHX Text
2-LUGT2
AutoCAD SHX Text
HGT-2/3
AutoCAD SHX Text
2-HTWM16 or 20
AutoCAD SHX Text
CONNECTOR
AutoCAD SHX Text
1-HTWM16 or 20
AutoCAD SHX Text
RETROFIT STRAPS TO CONCRETE/MASONRY
AutoCAD SHX Text
TO 9790
AutoCAD SHX Text
TRUSS UPLIFT (LBS)
AutoCAD SHX Text
TO 1145
AutoCAD SHX Text
TO 4520
AutoCAD SHX Text
TO 2290
AutoCAD SHX Text
TO 3610
AutoCAD SHX Text
TO 1145
AutoCAD SHX Text
@ 24" OC
AutoCAD SHX Text
HTT16
AutoCAD SHX Text
8-10dx1~8", 4-~4x2~4 CONCRETE SCREW
AutoCAD SHX Text
EPOXY 12" EMBED WITH USP SET.
AutoCAD SHX Text
8-10dx1~8", 4-~4x2~4 CONCRETE SCREW
AutoCAD SHX Text
8-10dx1~8", 4-~4x2~4 CONCRETE SCREW
AutoCAD SHX Text
16-16d, 7-~4"x2~4" CONCRETE SCREW
AutoCAD SHX Text
18-10d, ~0"~D ALLTHREAD, DRILL
AutoCAD SHX Text
& EPOXY 10" EMBED w/ USP SET.
AutoCAD SHX Text
TWO ~w"~D ALTHREAD, DRILL &
AutoCAD SHX Text
SHEATHING SCHEDULE
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
N/A
AutoCAD SHX Text
EXTERIOR STUD WALL
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
EXTERIOR CEILING AND SOFFIT
AutoCAD SHX Text
OPTIONS: 1) 1x4 STRIPPING @ 16"OC w/ 2-8d NAILS TO EACH TRUSS, ~0" EXTERIOR GYPBOARD CEILING, FASTEN w/8d NAILS OR 1~0" DRYWALL SCREWS @ 6"OC EDGE & FIELD. 2) ~6" BC PLYWOOD NAILED w/ 6d COMMON @ 6" OC EDGE & FIELD. 3) VINYL OR ALUMINUM PERFORATED SOFFIT INSTALLED PER MANUFACTURER INSTRUCTIONS TO MEET WIND PRESSURES PER R703.1.2.1.
AutoCAD SHX Text
A.P.A. RATED SHEATHING, EXPOSURE 1, SPAN RATING 24/16 OR BETTER. FASTEN WITH 8d RING SHANK NAILS @ 6" O.C. EDGE AND 6" O.C. FIELD.
AutoCAD SHX Text
(RING SHANK NAILS PER R803.2.3.1: 0.113" NOMINAL SHANK DIAMETER, RING DIA. OF 0.012" OVER SHANK DIAMETER, 16 TO 20 RINGS PER INCH, 0.280" DIAMETER FULL ROUND HEAD, 2" NAIL LENGTH)
AutoCAD SHX Text
NOTE: EXTERIOR CEILINGS AND SOFFITS 1) AND 2) SPECIFIED : EXTERIOR CEILINGS AND SOFFITS 1) AND 2) SPECIFIED HERE MEET THE DESIGN WIND PRESSURES PER R703.1.2.1.
AutoCAD SHX Text
7/16" ZIP SYSTEM WALL SHEATHING BY HUBER ENGINEERED WOODS LLC, NAILED W/ 8d COMMON WIRE @ 6" O.C. EDGE AND 6" O.C. FIELD. PROVIDE 2x4 BLOCKING AT ALL JOINTS. INSTALL SHEATHING AND SEAM TAPE IN STRICT ACCORDANCE WITH MFR. WRITTEN INSTRUCTIONS.
AutoCAD SHX Text
(WHEN ~8" ZIP BRAND ROOF SHEATHING IS USED, H-CLIPS ARE NOT REQUIRED) REQUIRED)
AutoCAD SHX Text
%%UOUTLOOKER DETAIL
AutoCAD SHX Text
SCALE: N.T.S.
AutoCAD SHX Text
12
AutoCAD SHX Text
APPROVED ISOLATION PLATE
AutoCAD SHX Text
8"x8" CONTINUOUS MASONRY BOND BEAM w/ 1-#5, GROUT SOLID. PROVIDE CORNER BARS PER DETAIL 6/S-3
AutoCAD SHX Text
#5 VERT. IN GROUTED CELL AT DOT LOCATIONS ON PLAN (48" OC MAX EXTERIOR)
AutoCAD SHX Text
#5 VERTICAL SHALL HAVE 7" STANDARD HOOK INTO TOP OF BOND BEAM
AutoCAD SHX Text
%%UFULL HEIGHT WALL SECTION
AutoCAD SHX Text
FINISHED GRADE, SEE SITE PLAN
AutoCAD SHX Text
3" CLEAR COVER TO REINFORCING
AutoCAD SHX Text
EMBED DOWELS 5" WITH 10" STD HOOK
AutoCAD SHX Text
MONOLITHIC FOOTING, SEE PLAN
AutoCAD SHX Text
DOWEL TO MATCH WALL REINFORCING, LAP 25"
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
12
AutoCAD SHX Text
EMBEDDED STRAP AT EACH ROOF TRUSS, SEE ROOF PLAN. BREAK OUT WEB OF BLOCK AS NEEDED TO PROPERLY LOCATE EACH STRAP
AutoCAD SHX Text
SOFFITS SHALL MEET WIND DESIGN PRESSURES PER R703.1.2.1. FOR FIELD FRAMING, SEE TABLE 2/S-3
AutoCAD SHX Text
WOOD TRUSSES @ 24" OC, DESIGNED BY DELEGATED TRUSS ENGINEER
AutoCAD SHX Text
ROOF SHEATHING, SEE SCHEDULE 2/S-3
AutoCAD SHX Text
5
AutoCAD SHX Text
2x4 OUTLOOKER @ 24" O.C.
AutoCAD SHX Text
ROOF SHEATHING, SEE SCHEDULE
AutoCAD SHX Text
2x4 BLOCK AT
AutoCAD SHX Text
SHEATHING JOINT
AutoCAD SHX Text
3-12d TOE NAILS
AutoCAD SHX Text
WALL SHEATHING
AutoCAD SHX Text
TOP CHORD OF GABLE END TRUSS
AutoCAD SHX Text
9
AutoCAD SHX Text
8"x8" BOND BEAM w/ 1-#5
AutoCAD SHX Text
#5 VERTICAL IN GROUTED CELL AT DOT LOCATIONS ON PLAN
AutoCAD SHX Text
7" STANDARD HOOK INTO TOP OF BOND BEAM (MAY USE 7"x25" BENT BAR)
AutoCAD SHX Text
%%UBOND BEAM & REINFORCING
AutoCAD SHX Text
MASONRY WALL
AutoCAD SHX Text
VERTICAL BAR IN GROUTED CELL, SEE PLAN
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
BEARING
AutoCAD SHX Text
"OB" DENOTES NO REBAR IN LINTEL, "1B" DENOTES 1#5 IN LINTEL
AutoCAD SHX Text
%%UROUGH OPENING
AutoCAD SHX Text
PRECAST LINTEL
AutoCAD SHX Text
4" MINIMUM BEARING
AutoCAD SHX Text
THIS DETAIL ONLY USED FOR ELEVATION A
AutoCAD SHX Text
ROOF COVERING AS SELECTED BY BUILDER PER: FBCR905.2 ASPHALT SHINGLES FBCR905.3 CLAY AND CONCRETE TILE FBCR 905.4 METAL ROOF
AutoCAD SHX Text
S-3
AutoCAD SHX Text
3
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DESIGN/DRAWN
AutoCAD SHX Text
DWB/DWB
AutoCAD SHX Text
DWB
AutoCAD SHX Text
09/20/19
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
DR11048
AutoCAD SHX Text
SHEET OF 3
AutoCAD SHX Text
(239) 549-4554
AutoCAD SHX Text
CA# 8829
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
SYSTEMS
AutoCAD SHX Text
OF NORTH FLORIDA
AutoCAD SHX Text
1634 S.E. 47th STREET, SUITE #3
AutoCAD SHX Text
CAPE CORAL, FL 33904
AutoCAD SHX Text
STRUCTURAL ENGINEERING:
AutoCAD SHX Text
BUILDER:
AutoCAD SHX Text
5473 HOFFMAN STREET GULF COVE SPOT LOTS, FLORIDA LOT: 18 SUBDIVISION: GULF COVE SPOT LOTS
AutoCAD SHX Text
STRUCTURAL DETAILS
AutoCAD SHX Text
MODEL 1499 A
AutoCAD SHX Text
DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 6th EDITION (2017) RESIDENTIAL
AutoCAD SHX Text
JOB NO.
AutoCAD SHX Text
FOR SCOSTA TRUSSES, ELEVATION A, JOB # 44116, DATED: 05/24/18, REVISED: 09/15/18