  • 1. INTERIOR BATHROOMS SHALL BE MECHANICALLY VENTILATED TO PROVIDE

    FOUR (4) CHANGES OR AIR PER HOUR, KITCHENETTE AREAS SHALL BE

    MECHANICALLY VENTILATED TO PROVIDE SIX (6) CHANGES OR AIR PER HOUR.

    2. ALL ASPECTS OF MECHANICAL VENTILATION SYSTEMS SHALL COMPLY WITH

    SECTION 37 OF THE M.D.L. AND ALL OTHER APPLICABLE SECTIONS.

    3. A STATEMENT SHALL BE FILED BY THE OWNER THAT STATES THE

    MECHANICALLY VENTILATION SYSTEMS WILL BE OPERATED CONTINUOSLY AT AL

    TIMES DURING THE NORMAL OCCUPANCY OF THE STRUCTURE AS PROVIDED IN

    THE APPLICABLE SECTION OF THE CODE.

    4. BATHROOM DUCTS SHALL BE A MINIMUM OF 20gr. GALVANIZED METAL

    KITCHENETTE DUCTS SHALL BE A MINIMUM OF 18gr. GALVANIZED METAL, ALL

    DUCTS SHALL BE A MINIMUM OF 5" dia. AND BOXED IN AS REQUIRED PER FIRE

    RETARDING EXPLAINED BELOW.

    5. DUCTS SHALL BE SUPPORTED AT EVERY FLOOR AND PER RS 13-1 AND 13-2.

    ALL JOINTS AND ELBOWS SHALL BE TIGHT FITTING AND SCREWED.

    6. FIRE RETIED ALL DUCWORK HAVING A CROSS SECTIONAL ARE OF UNDER

    2SQFT WITH CONSTRUCTION HAVING A FIRE RESISTANCE RATING OF 1 HR

    PLACED AS CLOSE AS POSSIBLE

    7. EXACT LOCATION OF THE DUCT RUNS SHALL BE COORDINATED WITH THE

    ARCHITECT IN THE FIELD.

    8. EACH BATHROOM EXHAUST FAN SHALL BE INDIVIDUALLY WIRED TO OPERATE

    WITH THE BATHROOM LIGHT SWITCH. EACH KITCHENETTE EXHAUST FAN SHALL

    BE WIRED AND SWITCHED INDEPENDENTLY.

    MECHANICAL VENTILATION NOTES:

    1. CONTACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AND DIMENTIONS

    AND SHALL REPORT AND DISCREPANCES TO THE ARCHITECT PROR TO

    COMMENCEMENT OF WORK.

    2. CONTRACTORS SHALL OBTAIN ALL REQUIRED AND NECESSARY PERMITS

    FROMM ALL MUNICIPAL AGENCIES HAVING JURISDICTION. NO WORK SHALL

    PROCEED UNLEES PERMIT IS OBTAINED AND DISPLAYED AT OBVIOUS LOCATION

    AT FRONT OF PREMISES.

    3. UPON COMPLETION OF WORK, CONTRACTORS WILL BE RESPONSIBILE FOR

    CALLING FOR INSPECTIONS AND OBTAINING SIGN-OFFS FOR CONSTRUCTION,

    PLUMBING AND ELECTRIC WORK.

    4. CONTRATOR SHALL CARRY WORKMAN'S COMPESATION INSURANCE AND

    DISABILITY BENEFITS AND ALL OTHER INSURANCE PAPERS REQUIRED.

    5. CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS OF THE NEW YORK

    CITY BUILDING CODE AND ALL OTHER RULES AND REGULATIONS OF THE COUNT

    AND STATE AS THEY APPLY TO THIS ALTERATION.

    6. DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUAL FIELD CONDITIONS

    AND THE WORK OF OTHER TRADES PERMIT, ANY PIPING WIRING OR OTHER

    MATERIALS NOT SPECIFICALLY SHOWN OR SPECIFIED BUT NEEDED TO

    COMPLETE THE WORK SHALL BE DEEMED TO BE PART OF THESE

    SPECIFICATIONS AND SHALL BE FURNISHED AND INSTALLED BY THE

    CONTRACTOR.

    GENERAL NOTES:

    1. BUILDING SHALL COMPLY WITH SECTION D.26.03 H.M.C. DRAINAGE OF ROOFS

    AND COURT YARDS.

    2. BUILDING SHALL COMPLY WITH SECTION D.26 -17.01 H.M.C. CENTRAL HEAT.

    3. BUILDING SHALL COMPLY WITH SECTION D.26 - 17.07 H.M.C. SUPPLY HOTWATER.

    4. BUILDING SHALL COMPLY WITH SECTION D.26 - 17.09 H.M.C. GAS - FUELED ORELECTRIC HEATERS WHERE PERMITED.

    5. BUILDING SHALL COMPLY WITH SECTION D.26 - 19.01 H.M.C. ELECTRICLIGHTING EQUIPMENT IN DWELLINGS.

    6. BUILDING SHALL COMPLY WITH SECTION D.26 - 19.03 H.M.C. ELECTRICLIGHTING IN PUBLIC AREAS.

    7. BUILDING SHALL COMPLY WITH SECTION D.26 - 20.05 H.M.C. LOCKS IN DOORS.

    8. BUILDING SHALL COMPLY WITH SECTION D.26 - 21.05 H.M.C. STREETNUMBERS.

    9. BUILDING SHALL COMPLY WITH SECTION D.26 - 30.11 H.M.C. LIGHTING ANDVENTILATION.

    10. BUILDING SHALL COMPLY WITH SECTION D.26 - 31.13 H.M.C. SANITARYFACILITIES.

    HOUSING MAINTENANCE NOTES:

    1. THE ELECTRIC INSTALLATION AND REPAIRS SHALL BE IN STRICT ACCORDANCE

    WITH THE NEW YORK CITY CODE AND OTHER CODES OR AGENCIES HAVING

    JURIDICTION.

    2. CONTRACTOR SHALL PROCURE RECUIRED PERMITS FOR HIS WORK.

    3. EACH DWELLING UNIT SHALL BE PROVIDED WITH A SEPARATE METER.

    4. ALL EXPOSED WIRING, UNLESS OTHERWISE NOTED SHALL BE INSTALLED IN

    EMT CONDUIT. ALL CONCEALED WIRING MAY BE FLEXIBLE METALIC CONDUIT.

    5. SMOKE DETECTORS SHALL BE INSTALLED IN WIRING BEFORE ELECTRICAL

    SWITCHES ARE WIRED INTO LINE.

    ELECTRICAL NOTES:

    1. MECHANICAL AND PLUMBING WORK SHALL BE FILED AS REQUIRED WITH THE

    APPROPRIATE CITY AGENCIES, UPOM COMPLETION WORK, CONTRACTOR SHALL

    ARRANCE FOR AND OBTAIN RELEVANT SIGN-OFF.

    2. ALL MECHANICALL AND PLUMBING WORK SHALL CONFORM TO THE NYC CODE

    AND ALL LOCAL LAWS.

    MECHANICAL & PLUMBING NOTES:

    1. EACH DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE DETECTING DEVICES

    RECEIVING THEIR PRIMARY POWER FROM THE BUILDING WIRING AND THERE

    SHALL BE NO SWITCHES IN THE CIRCUIT OTHER THAN THE OVER CURRENT

    DEVICE PROTECTING THE BRANCH.

    2. NO DEVICE SHALL BE DEEMED TO BE IN COMPLIANCE WITH BUILDING

    DEPARTMENT REQUIREMENTS UNLESS IT IS OF WITHER THE IONIZATION

    CHAMBER OR PHOTOELECTRIC TYPE, SUCH DEVICE SHALL BE IN COMPLIANCE

    WITH THE REQUIREMENTS OF REFERENCE STANDARD RS 17-1.

    3. SMOKE DETECTOR SHALL BE LOCATED WITHIN 15'0' OF BEDROOM DOORS.

    BUILDING DEPARTMENT NOTES:1. ALL NEW CONSTRUCTION SHALL ADHERE TO THE NEW YORK STATE ENERGY

    CONSERVATION GUIDELINES.

    2. ALL CONSTRUCTION WORK SHALL BE CONFINED TO THE AREAS SHOWN ON

    PLANS AND SHALL NOT BLOCK ANY MEANS OF EGRESS.

    3. CONSTRUCTION WORK SHALL TAKE PLACE BETWEEN TO THE HOURS OF 8:00

    A.M. AND 5:00 P.M.

    SMOKE DETECTION NOTES:

    Table 3-4 CONCTRUCTION CLASS IID

    EXTERIOR WALL BETWEEN 3' OR

    LESS - BEARING 2HR

    -NON BEARING 2HR

    BETWEEN 3' AND 15'-BEARING 1HR

    -NON BEARING 1HR

    BETWEEN 15' AND 30' 1HR

    -NON BEARING 1HR

    30' OR MORE'-BEARING 1 HR

    -NON BEARING 0 HR

    INTERIOR BEARING PARTITION 1 HR

    ENCLOSURE OF VERTICAL EXITS 2 HR

    FLOOR CONSTRUCTION 1HR

    ROOF CONSTRUCTION

    3

    4

    HR

    CONTRACTOR SHALL PROVIDE CONTROLLED INSPECTIONS IN ACCORDANCE

    WITH APPLICABLE NYC BUILDING CODE PROVISIONS. WORK SUBJECT TO

    CONTROLLED INSPECTIONS SHALL INCLUDE THE FOLLOWING:

    SPECIAL INSPECTION

    "HARDWIRED CARBON MONOXIDE DETECTORS COMPLYING WITH RS 17-13 AND

    INSTALLED IN ACCORDANCE WITH 17-14 SHALL BE PROVIDED IN EVERY DWELLING

    UNITWITHIN 15 FEET OF THE PRIMARY ENTRANCE TO EACH BEDROOM."

    TR3 & TR2 EXEMPTIONS

    The work meets the exemption criteria of Buildings Bulletin

    2009-026, item IV, and i herby elect to waive the requirement

    of concrete testing and of the TR2 form and/or TR3 form.

    * The total structural concrete specified for the project is

    * The structural design of the concrete is based on a

    specified compressive strength, fc, no greater than

    2,500 pounds per square inch (psi) (17.2 MPa) ,

    regardless of the compressive strength specified in the

    construction documents or used in the construction; and

    * The concrete to be placed is specified to have a

    compressive strength of at least 4,000 psi (28 MPa)

    NOTE:A-001 ZONING ANALYSIS, SITE PLAN, GENERAL NOTES

    A-004 ELEVATIONS, SECTIONS

    DRAWING LIST

    DEMOLITION FLOOR PLAN, NOTE

    RISER DIAGRAMS, DETAILS

    EXISTING: 3 STORY BRICK DWELLING

    PROPOSED DEVELOPMENT:

    INTERIOR ALTERATION.

    SCOPE OF WORK

    ENERGY CODE PROGRESS INSPECTION

    TAB. REFERENCE 1RCNY

    PROGRESS INSPECTIONSY N

    PROTECTION OF FOUNDATION INSULATION (IA1), (IIA1)

    INSULATION PLACEMENT AND R VALUES(IA2), (IIA2)

    FENESTRATION THERMAL VALUES AND RATINGS (IA3), (IIA3)

    FENESTRATION RATINGS FOR AIR LEAKAGE (IA4), (IIA4)

    FENESTRATION AREAS (IA5), (IIA5)

    AIR SEALING AND INSULATION - VISUAL (IA6), (IIA6)

    AIR SEALING AND INSULATION - TESTING (IA7)

    PROJECTION FACTORS (IIA7)

    LOADING DECK WEATHER SEALS (IIA8)

    VESTIBULES (IIA9)

    FIREPLACES (IB1), (IIB1)

    DAMPERS INTEGRAL TO BUILDING ENVELOPE (IB2), (IIB2)

    HVAC AND SERVICE WATER HEATING EQUIPMENT (IB3), (IIB3)

    HVAC AND SERVICE WATER HEATING SYSTEM CONTROLS (IB4), (IIB4)

    DUCT PLENUM AND PIPING INSULATION AND SEALING (IB5), (IIB5)

    DUCT LEAKAGE TESTING (IB6), (IIB6)

    ELECTRICAL METERING (IC1), (IIC1)

    LIGHTING IN DWELLING UNITS (IC2), (IIC2)

    INTERIOR LIGHTING POWER (IIC3)

    EXTERIOR LIGHTING POWER (IIC4)

    LIGHTING CONTROLS (IIC5)

    EXIT SIGNS (IIC6)

    TANDEM WIRING (IIC7)

    ELECTRICAL MOTORS (IIC8)

    TENANCE INFORMATION

    PERMANENT CERTIFICATE

    (ID1), (IID1)

    (ID2)

    X

    X

    X

    X

    X

    NOTE:TO THE BEST OF MY KNOWLEDGE , BELIEF AND PROFESSIONAL JUDGMENT,THESE PLANS AND

    SPECIFICATIONS ARE IN COMPLIANCE WITH THE ENERGY CONSERVATION CONSTRUCTION

    CODE OF NEW YORK STATE, USING CHAPTER - CHAPTER IV

    X

    X

    X

    SPECIAL INSPECTION CODE / SECTION

    FINAL INSPECTION. DIRECTIVE 14

    SOILS - SITE PREPARATION

    BC 1704.7.1

    SOILS - INVESTIGATIONS (BORINGS/TEST PITS)

    TR4 BC 1704.7.4

    PILE FOUNDATIONS & DRILLED

    PIER INSTALLATION

    TR5 BC 1704.8

    MECHANICAL SYSTEMS

    BC 1704.15

    STRUCTURAL SAFETY - STRUCTURAL STABILITY

    BC 1704.19

    SOIL PERCOLATION TEST - DRYWELL

    BC 1704.20.1

    SITE STORM DRAINAGE DISPOSAL

    AND DETENTION SYSTEM INSTALLATION

    BC 1704.20

    HEATING SYSTEMS

    BC 1704.23

    FIRESTOP, DRAFTSTOP, AND FIREBLOCK SYSTEMS

    BC 1704.25

    PROGRESS INSPECTION ITEMS CODE / SECTION

    FRAME INSPECTION

    ENERGY CODE COMPLIANCE INSPECTIONS

    BC 109.3.2

    BC 109.3.3