9
2014. 09 Communication protocols for controlled device in HES

2014. 09. Ⅰ Ⅰ Background Ⅱ Ⅱ Problems Ⅲ Ⅲ Need for a new protocol Protocol overview Ⅳ Ⅳ Conclusion Ⅴ Ⅴ

Embed Size (px)

Citation preview

Page 1: 2014. 09. Ⅰ Ⅰ Background Ⅱ Ⅱ Problems Ⅲ Ⅲ Need for a new protocol Protocol overview Ⅳ Ⅳ Conclusion Ⅴ Ⅴ

2014. 09

Communication protocols forcontrolled device in HES

Page 2: 2014. 09. Ⅰ Ⅰ Background Ⅱ Ⅱ Problems Ⅲ Ⅲ Need for a new protocol Protocol overview Ⅳ Ⅳ Conclusion Ⅴ Ⅴ

ⅠⅠ Background

ⅡⅡ Problems

ⅢⅢ Need for a new protocol

Contents

Protocol overviewⅣⅣ

ConclusionⅤⅤ

Page 3: 2014. 09. Ⅰ Ⅰ Background Ⅱ Ⅱ Problems Ⅲ Ⅲ Need for a new protocol Protocol overview Ⅳ Ⅳ Conclusion Ⅴ Ⅴ

3

Controlled devices in HES

Internet

Light

Wallpad

CurtainBatch

circuit breakerThermostatMeter

Boiler

Door lockGas valve

Residentialgateway

Airconditioner Security

Ventilationfan

StandardTargets

Background

: Wireless : Wired

Page 4: 2014. 09. Ⅰ Ⅰ Background Ⅱ Ⅱ Problems Ⅲ Ⅲ Need for a new protocol Protocol overview Ⅳ Ⅳ Conclusion Ⅴ Ⅴ

4

Interoperability issues between variety device vendors

Devices must be developed whenever the counter devices are changed.

Development period would be longer.

After HES setting up with self made protocol, new vendor hardly can join the existing

HES.

Aftermarket and consumer market can not be formed.

Replacements can not be found when the devices break down.

Also, the residents want to change the devices on their personal preferences.

Detached house owner want to set up DIY HES.

Problems

Page 5: 2014. 09. Ⅰ Ⅰ Background Ⅱ Ⅱ Problems Ⅲ Ⅲ Need for a new protocol Protocol overview Ⅳ Ⅳ Conclusion Ⅴ Ⅴ

5

Need for a new protocol

Protocol requirement

Be light for poor resources

Be simple and easy

Be inexpensive for implementation

Light

Doorlock

Gas valveAir

conditionerSecurity Boiler

CurtainBatchcircuit breaker

Thermostat Meter

Ventilationfan

Wallpad

Simple devices with poor resourcesby small companies

Complex devices with rich resourcesby large company

Page 6: 2014. 09. Ⅰ Ⅰ Background Ⅱ Ⅱ Problems Ⅲ Ⅲ Need for a new protocol Protocol overview Ⅳ Ⅳ Conclusion Ⅴ Ⅴ

6

Protocol overview

Launching HES standard forum(since 2005)

Goal : Development of communication protocols reflecting the real HES

Members : 30 device vendors

Achievements : 12 Voluntary standards

Standardization body : Telecommunications Technology Association(TTA)

Next stage : Korea Standards and International Standards

Current status

Implemented by 20 device vendors.

Development of conformance test tool and interoperability test specifica-

tion is in Progress.

National testing and certification system will be set up based on ISO

17025/Guide 65.

LightDoorlock

Gas valve Airconditioner Security Boiler CurtainBatch

circuit breakerThermostatMeter Ventilation

fan

Page 7: 2014. 09. Ⅰ Ⅰ Background Ⅱ Ⅱ Problems Ⅲ Ⅲ Need for a new protocol Protocol overview Ⅳ Ⅳ Conclusion Ⅴ Ⅴ

7

Protocol overview

Protocol stack

Message format

Serial Communications(RS-232, RS-485 etc.)

802.15.4 Layer 1 ~ 2

Protocol for HES Layer 7

Header

De-vice ID

De-vice Sub-ID

Command Type

Length Data XOR Add

sum

1 Byte 1 Byte 1 Byte 1 Byte 1 Byte Vari-able

1 Byte

1 Byte11 Devices Single,

GroupCharacteristic,

Status,Control

Datalength

Error,Control,

Reserved

0xF7 Message error check

Page 8: 2014. 09. Ⅰ Ⅰ Background Ⅱ Ⅱ Problems Ⅲ Ⅲ Need for a new protocol Protocol overview Ⅳ Ⅳ Conclusion Ⅴ Ⅴ

8

Protocol overview

This voluntary standards includes :

Minimum configurations of communications

Message sequence and timing

Error handling

Cabling and terminal register

Examples

Main Device Controlled Devices1. Characteristic request

2. Characteristic response

3. Status request

4. Status response

5. Control request

6. Controlled status response

Request time : Min 10ms

Response time : Min. 10ms, Max. 15ms

Page 9: 2014. 09. Ⅰ Ⅰ Background Ⅱ Ⅱ Problems Ⅲ Ⅲ Need for a new protocol Protocol overview Ⅳ Ⅳ Conclusion Ⅴ Ⅴ

9

Conclusion

Advantages of this standard

Light and suitable for poor resource(ex. Microcontroller based on Tiny OS)

Simple and easy

Low development cost

This proposed standard is verified for 5 years by 20 vendors.

Once conformance testing and certification system set up, it would be imple-

mented widely.