38
Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. © Kawneer Company, Inc., 2010 kawneer.com EC 97911-24 1 1600 WALL SYSTEM ®1 NOVEMBER, 2010 FEATURES For specific product applications, Consult your Kawneer representative. Features 1600 Wall System ®1 is an outside glazed captured curtain wall 1600 Wall System ®1 has a 2-1/2" (63.5) sight line Standard 6" (152.4) or 7-1/2" (190.5) depth systems Infill options up to 1-1/8" (28.6) Concealed fastener joinery creates smooth, monolithic appearance Open-back horizontals and perimeters are available for cost savings Shear block fabrication method Corners and splayed mullions available Offers integrated entrance framing systems Silicone compatible glazing materials for long-lasting seals 1600 Wall System ®1 has been small and large missile impact and cycle tested Two color option Permanodic ® anodized finishes in 7 choices Painted finishes in standard and custom choices Optional Features Steel reinforcing available Rain screen and backpans Optional deep profile and bull nose covers available Deep and heavy-weight mullions available Veneer system available Integrates with standard Kawneer windows and concealed GLASSvent™ Integrates with 1600 SUNSHADE TM and 1600 POWERSHADE ® Product Applications Ideal for low to mid-rise applications where high performance is desired It also is the right choice for high span applications

1600 CW--- kawneer

Embed Size (px)

Citation preview

Page 1: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

11600 WALL SYSTEM®1NOVEMBER, 2010

FEATURES

For specific product applications,Consult your Kawneer representative.

Features

• 1600WallSystem®1is an outside glazed captured curtain wall

• 1600WallSystem®1hasa2-1/2"(63.5)sightline

• Standard6"(152.4)or7-1/2"(190.5)depthsystems

• Infilloptionsupto1-1/8"(28.6)

• Concealedfastenerjoinerycreatessmooth,monolithicappearance

• Open-backhorizontalsandperimetersareavailableforcostsavings

• Shearblockfabricationmethod

• Cornersandsplayedmullionsavailable

• Offersintegratedentranceframingsystems

• Siliconecompatibleglazingmaterialsforlong-lastingseals

• 1600WallSystem®1hasbeensmallandlargemissileimpactandcycletested

• Twocoloroption

• Permanodic®anodizedfinishesin7choices

• Paintedfinishesinstandardandcustomchoices

Optional Features

• Steelreinforcingavailable

• Rainscreenandbackpans

• Optionaldeepprofileandbullnosecoversavailable

• Deepandheavy-weightmullionsavailable

• Veneersystemavailable

• IntegrateswithstandardKawneerwindowsandconcealedGLASSvent™

• Integrateswith1600SUNSHADETMand1600POWERSHADE®

Product Applications

• Idealforlowtomid-riseapplicationswherehighperformanceisdesired

• Italsoistherightchoiceforhighspanapplications

Page 2: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

2 1600 WALL SYSTEM®1NOVEMBER, 2010

BLANK PAGE

Page 3: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

31600 WALL SYSTEM®1NOVEMBER, 2010

PICTORIAL VIEW ............................................................................... 5

1" InFILL DETAILS ............................................................................. 6

1/4" InFILL DETAILS .......................................................................... 7

EnTRAnCE DETAILS ..................................................................... 8,9

CORnERS ......................................................................................... 10

SPLAYED MULLIOn OPTIOnS ....................................................... 11

1600 WALL GLASSVEnT/WInDOWS .............................................. 12

BACKPAn AnD MISCELLAnEOUS DETAILS ................................ 13

REYnOBOnD® PAnEL DETAILS ..................................................... 14

MISCELLAnEOUS FRAMInG .......................................................... 15

HURRICAnE RESISTAnT DETAILS .......................................... 16,17

AnCHORInG ............................................................................... 18,19

WInD LOAD CHARTS ................................................................. 20-26

DEADLOAD CHARTS ................................................................. 27-29

THERMAL CHARTS ................................................................... 30-38

LAWSANDBUILDINGANDSAFETYCODESGOVERNINGTHEDESIGNANDUSEOFGLAZEDENTRANCE,WINDOW,ANDCURTAINWALLPRODUCTSVARYWIDELY.KAWNEERDOESNOTCONTROLTHESELECTIONOFPRODUCTCONFIGURATIONS,OPERATINGHARDWARE,ORGLAZINGMATERIALS,ANDASSUMESNORESPONSIBILITYTHEREFOR.

Metric(SI)conversionfiguresareincludedthroughoutthesedetailsforreference.Numbersinparentheses()aremillimetersunlessotherwisenoted.

Thefollowingmetric(SI)unitsarefoundinthesedetails:

m–meter

cm–centimeter

mm–millimeter

s–second

Pa–pascal

MPa–megapascal

Kawneerreservestherighttochangeconfigurationswithoutpriornoticewhendeemednecessaryforproductimprovement.

Architects-MostextrusionandwindowtypesillustratedinthiscatalogarestandardproductsforKawneer.Theseconceptshavebeenexpandedandmodifiedtoaffordyoudesignfreedom.Somemiscellaneousdetailsarenon-standardandareintendedtodemonstratehowthesystemcanbemodifiedtoexpanddesignflexibility.PleasecontactyourKawneerrepresentativeforfurtherassistance.

INDEX

Page 4: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

4 1600 WALL SYSTEM®1NOVEMBER, 2010

BLANK PAGE

Page 5: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

51600 WALL SYSTEM®1NOVEMBER, 2010

PICTORIAL VIEW

Page 6: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

6

2-1/

2"(6

3.5)

6" (152.4)

7 -1/2" (190.5)

1

3

2

4

5

66A

99A9B

1A

88A

7

2-1/2"(63.5)

6" (

152.

4)

7-1/

2" (

190.

5)

1A

2

3

4

5

66A

8

7

8A

9

9A 9B

1

1600 WALL SYSTEM®1NOVEMBER, 2010

SCALE 3" = 1'-0"

ELEVATIOn IS nUMBER KEYED TO DETAILS

OPTIONALSTEELREINFORCINGASREQUIRED

1" INFILL DETAILS

Page 7: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

7

1

2

55A

6

77A7B

1A

3

4

6A

2-1/

2"(6

3.5)

5-1/4" (133.4)

6 -3/4" (171.5)2-1/2"(63.5)

5-1/

4" (

133.

4)

6 -3

/4"

(171

.5)

1A

2

3

4

1

6

6A

7

7A 7B

5A 5

1600 WALL SYSTEM®1NOVEMBER, 2010

SCALE 3" = 1'-0"

ELEVATIOn IS nUMBER KEYED TO DETAILS

OPTIONALSTEELREINFORCINGASREQUIRED

1/4" INFILL DETAILS

Page 8: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

8

7/8"(22.2)TYP.

1-15

/16"

(88.

9)T

YP.

1

2

4

6

3

1A

5

2 4

11A 3

6

5

1600 WALL SYSTEM®1NOVEMBER, 2010

ELEVATIOn IS nUMBER KEYED TO DETAILS

TRAnSOM BARBUTT HUnG OR OFFSET PIVOT

WITH LCn COnCEALED OVER HEAD CLOSER

OR SURFACE CLOSER

TRAnSOM BARCEnTER HUnG

COnCEALED OVERHEADOR FLOOR CLOSER

TRAnSOM BARBUTT HUnG OR

OFFSET PIVOT WITHSURFACE CLOSER

OR FLOOR CLOSER

TRAnSOM BARBUTT HUnG OR OFFSET PIVOT

WITH SInGLE ACTInGOFFSET ARM CLOSER

DOOR JAMBBUTT HUnG OROFFSET PIVOT

DOOR JAMBCEnTER HUnG

DOOR JAMBBUTT HUnG OROFFSET PIVOT

SCALE 3" = 1'-0"

ENTRANCE DETAILS (1" INFILL)

B/H OR O/P C/H B/H OR O/P

Page 9: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

9

1-15

/16"

(88.

9)T

YP.

7/8"(22.2)TYP.

1A

1

3

2

4

2 4

31

1A

1600 WALL SYSTEM®1NOVEMBER, 2010

SCALE 3" = 1'-0"

ELEVATIOn IS nUMBER KEYED TO DETAILS

TRAnSOM BARBUTT HUnG OR

OFFSET PIVOT WITHSURFACE CLOSER

OR FLOOR CLOSER

TRAnSOM BARCEnTER HUnG

COnCEALED OVERHEADOR FLOOR CLOSER

TRAnSOM BARBUTT HUnG OR OFFSET PIVOT

WITH SInGLE ACTInGOFFSET ARM CLOSER

DOOR JAMBBUTT HUnG OROFFSET PIVOT

DOOR JAMBCEnTER HUnG

ENTRANCE DETAILS (1/4" INFILL)

B/H OR O/P C/H

Page 10: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

10 1600 WALL SYSTEM®1NOVEMBER, 2010

nOTE: 1" SYSTEM SHOWn, 1/4" SYSTEM SIMILAR.

90° OUTSIDE CORnER 90° InSIDE CORnER

90° OUTSIDE CORnER 135° OUTSIDE CORnER

135° InSIDE CORnER135° OUTSIDE CORnER

SCALE 3" = 1'-0"

CORNERS

Page 11: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

111600 WALL SYSTEM®1NOVEMBER, 2010

SCALE 3" = 1'-0"

OUTSIDE SPLAYED MULLIOnS

0° TO 5° 5° TO 15° 15° TO 25°

InSIDE SPLAYED MULLIOnS

0° TO 5° 5° TO 15° 15° TO 25°

SPLAYED MULLION OPTIONS

Page 12: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

12 1600 WALL SYSTEM®1NOVEMBER, 2010

1600 GLASSVEnT

8225 TL WInDOWS

HEAD

SILL

JAMB

SILL

HEAD

SCALE 3" = 1'-0"

nOTE: Other vent types can be accommodated. Contact your Kawneer representative for other options.

JAMB

1600 GLASSVENT/WINDOWS

Page 13: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

13

1

4

5

6

2

3

7

1/2"

(12

.7)

3/8"

(9.

5)

2-1/

2" (

63.5

)

3/8"

(9.

5)

7

4

5

6

1 2

3

1600 WALL SYSTEM®1NOVEMBER, 2010

SCALE 3" = 1'-0"

ELEVATIOn IS nUMBER KEYED TO DETAILS

NOTE:6"SYSTEMSHOWN,7-1/2"SYSTEMSIMILAR

HEAD TRAnSOM AT PARAPET FLASHInG

EXPAnSIOn JOInT

TYPICAL DEADLOAD AnCHOR

TRAnSOM – SPAnDREL OVER VISIOn

THERMALLY BROKEn DOOR ADAPTOR FOR InSULCLAD DOORS

JAMB MULLIOnAT SPAnDREL

MULLIOn AT SPAnDREL

CO

NS

TR

UC

TIO

NJ

OIN

T1/

2"(

12.7

)M

AX

(A

LLO

WS

+/-

1/4"

MO

VE

ME

NT

)

MU

LLIO

NL

EN

GT

HM

ULL

ION

LE

NG

TH

D.L

.O.

D.L

.O.

BACKPAN AND MISCELLANEOUS DETAILS

Page 14: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

14

1

2

3

4

5

6

7

9

8

1

2

4

5

6

3

7

8

9

1600 WALL SYSTEM®1NOVEMBER, 2010

SCALE 3" = 1'-0"

ELEVATIOn IS nUMBER KEYED TO DETAILS

nOTE:6"SYSTEMSHOWN,7-1/2"SYSTEMSIMILAR

*ReynobondACM(AluminumCompositeMaterial)ismanufacturedbyAlcoaCladdingSystems.

ReynobondACMpanelsareavailableinawidevarietyofsizesandshapesandarecoloredwithColorweld®300coatings. Colorweld®300coatingsareKynar500®/Hylar5000®finisheswhichfeaturedurablepolyvinylidenefluoride(PVDF)resins.Colorweld®300Series4finishesaredesignedtomatchKawneer'sanodizedcolors.

ForadditionalinformationonReynobondcontact770-840-6456.

GLAZED-In PAnEL- PRIME SEALED SHOWn WITH 4.0mm REYnOBOnD PAnEL, 6.0mm SIMILAR.- RAIn SCREEn, PRESSURE EQUALIZED (BACKPAn) OPTIOnAL

FLUSH PAnEL- PRIME SEALED SHOWn WITH 4.0mm REYnOBOnD PAnEL, 6.0mm SIMILAR.- RAIn SCREEn, PRESSURE EQUALIZED (BACKPAn) OPTIOnAL

PUnCHED OPEnInG / RIBBOn WInDOW InTEGRATIOn- SHOWn WITH 6.0mm REYnOBOnD PAnEL, 4.0mm SIMILAR.

REYNOBOND®* PANEL DETAILS

Page 15: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

15

2-1/

2"

(63.

5)

2-1/2"(63.5)

2-1/

2"(6

3.5)

813-997

4"(101.6)

6"(1

52.4

)7-1/

2"(1

90.5

)

807-237

813-973

814-827

807-239

10-1

/2"

(266

.7)

2-1/2"

(63.5)

162-064

1-3/

16"

(30.

1)

2"(5

0.8)

2-3/

4"(6

9.7)

2-1/2"(63.5)

804-206

162-243

804-713

1-1/

4"(3

1.8)

2-1/

2"(6

3.5)

3"(7

6.2)

4-3/

4"(1

20.7

)

2-1/2"(63.5)

162-073

162-074

162-239

804-736

162-075

1600 WALL SYSTEM®1NOVEMBER, 2010

SCALE 3" = 1'-0"

OPTIOnAL COVERS

VEnEER SYSTEM

4" SIGHT LInE

DEEP MULLIOn

InTERIOR STOOL TRIM

OPTIOnAL COVERS

DOUBLE MULLIOn

Architects–MostextrusionandwindowtypesillustratedinthiscatalogarestandardproductsforKawneer.Theseconceptshavebeenexpandedandmodifiedtoaffordyoudesignfreedom.Somemiscellaneousdetailsarenon-standardandareintendedtodemonstratehowthesystemcanbemodifiedtoexpanddesignflexibility.PleasecontactyourKawneerrepresentativeforfurtherassistance.

MISCELLANEOUS FRAMING

STOOL TRIM OPTIOnS:069-264-2-3/4"(69.9)069-265-4-1/2"(114.3)069-266-5"(127.0)069-267-6-1/8"(155.6)069-268-6-3/4"(171.4)

069-263GYPSUMBOARDTRIM

nOTE:STOOLTRIMSREQUIRE069-271TRIMCLIPPACKAGE

VARIES

Page 16: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

16

1

2

3

4

7 655A

98

10

7-1/16"(179.4)

2-1/

2"(6

3.5)

2-3/

4"(6

9.9)

3-19/32"(91.3)

3-19

/32"

(91.

3)

1600 WALL SYSTEM®1NOVEMBER, 2010

SCALE 3" = 1'-0"

HURRICANE RESISTANT DETAILS

ELEVATIOn IS nUMBER KEYED TO DETAILS

OPTIONALSTEELREINFORCINGASREQUIRED

1HEAD

2HORIZOnTAL

3EXPAnSIOn

HORIZOnTAL

4SILL

5JAMB

5AJAMB

6VERTICAL

790° CORnER

nOTE: DETAILSSHOWNWITH9/16"INFILLANDAREGLAZEDFORFORLARGEMISSLEIMPACT(LMI). SEENEXTPAGEFOROTHERGLAZINGOPTIONS.

Page 17: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

17

2-1/

2"(6

3.5)

3-1/

2"(8

8.9)

1-3/

4"(4

4.5)

1/8"

(3.2

)1/

8"

7-1/

16"

(179

.4)

2-1/2"(63.5)

3-1/2"(88.9)

3/4"(19.1)

3/32"(2.4)

10-1

/16"

(255

.6)

2-1/2"(63.5)

7-1/16"(179.4)

2-1/

2"(6

3.5)

7-13/16"(198.4)

2-1/

2"(6

3.5)

1600 WALL SYSTEM®1NOVEMBER, 2010

SCALE 3" = 1'-0"

HURRICANE RESISTANT DETAILS

10TRAnSOM BAR

9/16" InFILL (LMI)

8DOOR JAMBAT MULLIOn

9/16" InFILL (LMI)

9DOOR JAMB

AT PERIMETER

OPTIOnAL10" DEEP SYSTEM9/16" InFILL (LMI)

9/16" InFILL (SMI)SMALL MISSILE

IMPACT

9/16" InFILL (SMI)OVER

9/16" InFILL (LMI)

1-5/16" InFILL (SMI)SMALL MISSILE

IMPACT

1-5/16" InFILL (LMI)LARGE MISSILE

IMPACT

nOTE: 350IRDOORSAREUSEDWITHIMPACTFRAMING. DOORSAREGLAZEDWITH9/16"INFILL.

GLAZInG OPTIOnS

Page 18: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

18

1" (25.4) MINIMUM

1" (25.4) MINIMUM

1600 WALL SYSTEM®1NOVEMBER, 2010

Actualprojectconditionswilldeterminespecificanchordesign.Detailsonthispageareforreferenceonly.

AnCHORInG TO FLOOR SLAB

AnCHORInG TO SUPPORT STEEL

ANCHORING

Page 19: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

19

1" (25.4) MINIMUM

1" (25.4) MINIMUM

1600 WALL SYSTEM®1NOVEMBER, 2010

AnCHORInG TO HORIZOnTAL STRUCTURAL STEEL

AnCHORInG TO VERTICAL STRUCTURAL STEEL

Actualprojectconditionswilldeterminespecificanchordesign.Detailsonthispageareforreferenceonly.

ANCHORING

Page 20: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

20 1600 WALL SYSTEM®1NOVEMBER, 2010

WInD LOAD CHARTS

MullionsaredesignedfordeflectionlimitationsinaccordancewithAAMATIR-A11ofL/175upto13'-6"andL/240+1/4"above13'-6".ThesecurvesareformullionsWITHHORIZONTALSandarebasedonengineeringcalculationsforstressanddeflection.AllowablewindloadstressforALUMINUM15,152p.s.i.(104MPa),STEEL30,000p.s.i.(207MPa.).Chartedcurves,inallcasesareforthelimitingvalue.A4/3increaseinallowablestresshasnotbeenusedtodevelopthesecurves.Forspecialsituationsnotcoveredbythesecurves,contactyourKawneerrepresentativeforadditionalinformation.

DEADLOAD CHARTS

Horizontalordeadloadlimitationsarebasedupon1/8"(3.2),maximumallowabledeflectionatthecenterofanintermediatehorizontalmember.Theaccompanyingchartsarecalculatedfor1"(25.4)thickinsulatingglassor1/4"(6.35)thickglasssupportedontwosettingblocksplacedattheloadingpointsshown.

WIND LOAD / DEADLOAD CHARTS

Page 21: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

21

6" (

152.

4)6"

(15

2.4)

162-001

162-002

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

23

22

21

20

19

18

17

16

15

14

13

12

10

11

9

8

7

6

5

4

5

5.5

6

6.5

7

4.5

3.5

2.5

2

3

AB

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28

A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

23

22

21

20

19

18

17

16

15

14

13

12

10

11

9

8

7

6

5

4

5

5.5

6

6.5

7

4.5

3.5

2.5

2

3

A

B

C

D

E

1600 WALL SYSTEM®1NOVEMBER, 2010

I=5.035(209.57x104)S=1.993(32.66x103)

SInGLE SPAn TWIn SPAnA = 20 PSF (960)B = 30 PSF (1440)C = 40 PSF (1920)D = 50 PSF (2400)E = 60 PSF (2880)

I=6.779(282.16x104)S=2.652(43.46x103)

SInGLE SPAn TWIn SPAn

WIND LOAD CHARTS (1" INFILL)

MU

LL

IOn

HE

IGH

T

MU

LL

IOn

HE

IGH

TE

QU

AL

EQ

UA

L

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

TMETERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

MU

LL

IOn

HE

IGH

T

MU

LL

IOn

HE

IGH

TE

QU

AL

EQ

UA

L

Page 22: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

22

7-1/

2" (

190.

5)7-

1/2"

(19

0.5)

162-004

162-003

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

23

22

21

20

19

18

17

16

15

14

13

12

10

11

9

8

7

6

5

4

5

5.5

6

6.5

7

4.5

3.5

2.5

2

3

A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28

A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

23

22

21

20

19

18

17

16

15

14

13

12

10

11

9

8

7

6

5

4

5

5.5

6

6.5

7

4.5

3.5

2.5

2

3

A

B

C

D

E

1600 WALL SYSTEM®1NOVEMBER, 2010

I=12.736(530.11x104)S=3.791(62.12x103)

I=10.135(421.85x104)S=3.027(49.60x103)

WIND LOAD CHARTS (1" INFILL)

SInGLE SPAn TWIn SPAn

A = 20 PSF (960)B = 30 PSF (1440)C = 40 PSF (1920)D = 50 PSF (2400)E = 60 PSF (2880)

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

MU

LL

IOn

HE

IGH

T

MU

LL

IOn

HE

IGH

TE

QU

AL

EQ

UA

L

MU

LL

IOn

HE

IGH

T

MU

LL

IOn

HE

IGH

TE

QU

AL

EQ

UA

L

SInGLE SPAn TWIn SPAn

Page 23: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

23

7-1/

2" (

190.

5)

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28

A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28

A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28

A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28

A

B

C

D

E

1600 WALL SYSTEM®1NOVEMBER, 2010

SInGLE SPAn SInGLE SPAn

SInGLE SPAn162-004 W/162-300

162-004 W/162-301/302 162-004 W/162-301/302/303

162-004 W/162-301

SInGLE SPAn

162-004W/162-301/302/303Ia=12.736(530.11x104)Sa=3.791(62.12x103)Is=9.347(389.05x104)Ss=4.100(67.19x103)

Ia=12.736(530.11x104)Sa=3.791(62.12x103)Is=3.805(158.37x104)Ss=1.669(27.35x103)

162-004W/162-300

162-004W/162-301

Ia=12.736(530.11x104)Sa=3.791(62.12x103)Is=5.684(236.59x104)Ss=2.493(40.85x103)

Ia=12.736(530.11x104)Sa=3.791(62.12x103)Is=7.893(328.53x104)Ss=3.462(56.73x103)

162-004W/162-301/302

WIND LOAD CHARTS (1" INFILL)

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

TMETERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

MU

LL

IOn

HE

IGH

TM

UL

LIO

n H

EIG

HT

A = 20 PSF (960)B = 30 PSF (1440)C = 40 PSF (1920)D = 50 PSF (2400)E = 60 PSF (2880)

Page 24: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

24

5-1/

4" (

133.

4)5-

1/4"

(13

3.4)

162-013

162-014

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

23

22

21

20

19

18

17

16

15

14

13

12

10

11

9

8

7

6

5

4

5

5.5

6

6.5

7

4.5

3.5

2.5

2

3

A

B

CD

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28

A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

23

22

21

20

19

18

17

16

15

14

13

12

10

11

9

8

7

6

5

4

5

5.5

6

6.5

7

4.5

3.5

2.5

2

3

A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28

A

B

C

D

E

1600 WALL SYSTEM®1NOVEMBER, 2010

I=3.662(152.42x104)S=1.662(27.24x103)

I=4.5071(87.60x104)S=1.968(32.25x103)

WIND LOAD CHARTS (1/4" INFILL)

SInGLE SPAn TWIn SPAn

A = 20 PSF (960)B = 30 PSF (1440)C = 40 PSF (1920)D = 50 PSF (2400)E = 60 PSF (2880)

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

MU

LL

IOn

HE

IGH

T

MU

LL

IOn

HE

IGH

TE

QU

AL

EQ

UA

L

MU

LL

IOn

HE

IGH

T

MU

LL

IOn

HE

IGH

TE

QU

AL

EQ

UA

L

SInGLE SPAn TWIn SPAn

Page 25: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

25

6-3/

4" (

171.

5)6-

3/4"

(17

1.5)

162-015

162-016

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

23

22

21

20

19

18

17

16

15

14

13

12

10

11

9

8

7

6

5

4

5

5.5

6

6.5

7

4.5

3.5

2.5

2

3

A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

23

22

21

20

19

18

17

16

15

14

13

12

10

11

9

8

7

6

5

4

5

5.5

6

6.5

7

4.5

3.5

2.5

2

3

A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28A

B

C

D

E

1600 WALL SYSTEM®1NOVEMBER, 2010

I=9.594(399.33x104)S=3.163(51.83x103)

I=7.915(329.45x104)S=2.635(43.18x103)

WIND LOAD CHARTS (1/4" INFILL)

SInGLE SPAn TWIn SPAnA = 20 PSF (960)B = 30 PSF (1440)C = 40 PSF (1920)D = 50 PSF (2400)E = 60 PSF (2880)

SInGLE SPAn TWIn SPAn

MU

LL

IOn

HE

IGH

T

MU

LL

IOn

HE

IGH

TE

QU

AL

EQ

UA

L

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

TMETERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

MU

LL

IOn

HE

IGH

T

MU

LL

IOn

HE

IGH

TE

QU

AL

EQ

UA

L

Page 26: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

26

6-3/

4" (

171.

5)

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28

A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28

A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28

A

B

C

D

E

0 1 2 3 4 5 6 7 8

.5 1 1.5 2

4

5

5.5

6

6.5

7

4.5

7.5

29

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

8

8.5

930

27

28

A

B

C

D

E

1600 WALL SYSTEM®1NOVEMBER, 2010

162-016 W/162-300

162-016 W/162-301/302 162-016 W/162-301/302/303

162-016 W/162-301

162-016W/162-301/302/303Ia=9.594(399.33x104)Sa=3.163(51.83x103)Is=9.347(389.05x104)Ss=4.100(67.19x103)

162-016W/162-301

Ia=9.594(399.33x104)Sa=3.163(51.83x103)Is=5.684(236.59x104)Ss=2.493(40.85x103)

162-016W/162-301/302

Ia=9.594(399.33x104)Sa=3.163(51.83x103)Is=7.893(328.53x104)Ss=3.462(56.73x103)

162-016W/162-300

Ia=9.594(399.33x104)Sa=3.163(51.83x103)Is=3.805(158.37x104)Ss=1.669(27.35x103)

WIND LOAD CHARTS (1/4" INFILL)

SInGLE SPAn SInGLE SPAn

SInGLE SPAn SInGLE SPAn

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

METERS

MULLIONCENTERSINFEET

ME

TE

RS

MU

LLIO

NH

EIG

HT

INF

EE

T

MU

LL

IOn

HE

IGH

TM

UL

LIO

n H

EIG

HT

A = 20 PSF (960)B = 30 PSF (1440)C = 40 PSF (1920)D = 50 PSF (2400)E = 60 PSF (2880)

Page 27: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

27

6" (152.4)

7-1/2" (190.5)

6" (152.4)

7-1/2" (190.5)

162-001 162-002

162-003 162-004

.5 1 1.5 2

3.5

3

2.5

2

1.5

1

0.5

0 1 2 3 4 5 6 7 8

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

B

.5 1 1.5 2

3.5

3

2.5

2

1.5

1

0.5

0 1 2 3 4 5 6 7 8

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

B

.5 1 1.5 2

3.5

3

2.5

2

1.5

1

0.5

0 1 2 3 4 5 6 7 8

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

B

.5 1 1.5 2

3.5

3

2.5

2

1.5

1

0.5

0 1 2 3 4 5 6 7 8

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

B

1600 WALL SYSTEM®1NOVEMBER, 2010

A -1/4"GLASS(1/4POINTLOADING)B-1"GLASS(1/4POINTLOADING)

DEADLOAD CHARTS (TUBULAR)

METERS

SPANINFEET

ME

TE

RS

GLA

SS

HE

IGH

TIN

FE

ET

METERS

SPANINFEET

ME

TE

RS

GLA

SS

HE

IGH

TIN

FE

ET

METERS

SPANINFEET

ME

TE

RS

GLA

SS

HE

IGH

TIN

FE

ET

METERS

SPANINFEET

ME

TE

RS

GLA

SS

HE

IGH

TIN

FE

ET

Page 28: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

28

6-3/4" (171.5)

5-1/4" (133.4)

6-3/4" (171.5)

162-013 162-014

162-015 162-016

5-1/4" (133.4)

.5 1 1.5 2

3.5

3

2.5

2

1.5

1

0.5

0 1 2 3 4 5 6 7 8

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

.5 1 1.5 2

3.5

3

2.5

2

1.5

1

0.5

0 1 2 3 4 5 6 7 8

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

.5 1 1.5 2

3.5

3

2.5

2

1.5

1

0.5

0 1 2 3 4 5 6 7 8

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

.5 1 1.5 2

3.5

3

2.5

2

1.5

1

0.5

0 1 2 3 4 5 6 7 8

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

1600 WALL SYSTEM®1NOVEMBER, 2010

A -1/4"GLASS(1/4POINTLOADING)

DEADLOAD CHARTS (TUBULAR)

METERS

SPANINFEET

ME

TE

RS

GLA

SS

HE

IGH

TIN

FE

ET

METERS

SPANINFEET

ME

TE

RS

GLA

SS

HE

IGH

TIN

FE

ET

METERS

SPANINFEET

ME

TE

RS

GLA

SS

HE

IGH

TIN

FE

ET

METERS

SPANINFEET

ME

TE

RS

GLA

SS

HE

IGH

TIN

FE

ET

Page 29: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

29

6" (152.4) 7-1/2" (190.5) 5-1/4" (133.4)

162-094 162-095 162-096

6-3/4" (171.5)

162-097

6" (152.4) 7-1/2" (190.5)

.5 1 1.5 2

3.5

3

2.5

2

1.5

1

0.5

0 1 2 3 4 5 6 7 8

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

B

.5 1 1.5 2

3.5

3

2.5

2

1.5

1

0.5

0 1 2 3 4 5 6 7 8

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

B

.5 1 1.5 2

3.5

3

2.5

2

1.5

1

0.5

0 1 2 3 4 5 6 7 8

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

B

.5 1 1.5 2

3.5

3

2.5

2

1.5

1

0.5

0 1 2 3 4 5 6 7 8

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

B

.5 1 1.5 2

3.5

3

2.5

2

1.5

1

0.5

0 1 2 3 4 5 6 7 8

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

B

.5 1 1.5 2

3.5

3

2.5

2

1.5

1

0.5

0 1 2 3 4 5 6 7 8

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

B

1600 WALL SYSTEM®1NOVEMBER, 2010

A -1"GLASS(1/8POINTLOADING)B-1"GLASS(1/4POINTLOADING)

A -1"GLASS(1/8POINTLOADING)B-1"GLASS(1/4POINTLOADING)

A -1/4"GLASS(1/8POINTLOADING)B-1/4"GLASS(1/4POINTLOADING)

A -1/4"GLASS(1/8POINTLOADING)B-1/4"GLASS(1/4POINTLOADING)

A -1"GLASS(1/8POINTLOADING)B-1"GLASS(1/4POINTLOADING)

A -1"GLASS(1/8POINTLOADING)B-1"GLASS(1/4POINTLOADING)

162-090(DOTTED)

162-091(DOTTED)

162-092(DOTTED)

162-094162-090

(DOTTED)

162-095162-091

(DOTTED)

162-093(DOTTED)

162-077 REInF. 162-078 REInF.

DEADLOAD CHARTS (OPEN BACK)

METERS

SPANINFEET

ME

TE

RS

GLA

SS

HE

IGH

TIN

FE

ET

METERS

SPANINFEET

ME

TE

RS

GLA

SS

HE

IGH

TIN

FE

ET

METERS

SPANINFEET

ME

TE

RS

GLA

SS

HE

IGH

TIN

FE

ET

METERS

SPANINFEET

ME

TE

RS

GLA

SS

HE

IGH

TIN

FE

ET

METERS

SPANINFEET

ME

TE

RS

GLA

SS

HE

IGH

TIN

FE

ET

METERS

SPANINFEET

ME

TE

RS

GLA

SS

HE

IGH

TIN

FE

ET

Page 30: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

30

2-1/2" Typ.3'

-0"

4'-0

"8'

-0"

6'-0

"9'

-0"

31'-3

"

5'-0"

2-1/

2"Ty

p.

1600 WALL SYSTEM®1NOVEMBER, 2010

THERMAL CHARTS

VisionArea ExampleGlassU-factor =0.48Btu/(ft2·h·°F)

VisionArea =5(9+8+4)=105.0ft2

TotalArea(Vision) =5'2-1/2"(9'3-3/4"+8'2-1/2"+4'2-1/2")=113.2ft2

PercentageofVisionGlass =(VisionArea÷TotalArea)100 =(105.0÷113.2)100=93%SpandrelArea

ExampleSpandrelR-value =15(ft2·h·°F)/Btu

SpandrelArea =5(6+3)=45.0ft2

TotalArea(Spandrel) =5'2-1/2"(6'2-1/2"+3'3-3/4")=49.6ft2

PercentofSpandrel =(SpandrelArea÷TotalArea)100 =(45.0÷49.6)100=91%

Project Specific U-factor Example Calculation

(BasedonsinglebayofCurtainWall/WindowWall)

SPANDREL

VISION

VISION

SPANDREL

VISION

D.L.O.

D.L

.O.

D.L

.O.

D.L

.O.

D.L

.O.

D.L

.O.

Page 31: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

31

0.53

93%

0.480.460.440.420.400.380.360.340.320.300.280.260.240.220.20

0.70

0.80

0.60

0.50

0.40

0.30

0.2095 90 85 80 75 70

0.21

91%

2.00

3.00

4.00

5.00

11.0015.0019.0030.00

0.60

0.50

0.40

0.30

0.20

95 90 85 80 75 700.10

1600 WALL SYSTEM®1NOVEMBER, 2010

THERMAL CHARTS

Vision Area Chart

Spandrel Area Chart

System U-factor vs Percent of Vision Area

COGU-factor

Spandrel R-value

System U-factor vs Percent of Spandrel Area

Vision Area / Total Area (%)

Spandrel Area / Total Area (%)

Based on a single curtain wall bay of 91% spandrel and center of spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft 2·°F)

Based on a single curtain wall bay of 93% vision glass and center of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft 2·°F)

Btu

h

·ft

2 ·°F

S

yste

m U

-fac

tor

Btu

h

·ft

2 ·°F

S

yste

m U

-fac

tor

EXAMPLE

(NOT FOR DESIGN)

EXAMPLE

(NOT FOR DESIGN)

Page 32: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

32

0.48(2.73)0.46(2.61)0.44(2.50)0.42(2.39)0.40(2.27)0.38(2.16)0.36(2.05)0.34(1.93)0.32(1.82)0.30(1.71)0.28(1.59)0.26(1.48)0.24(1.37)0.22(1.25)0.20(1.14)

0.70

0.80

0.60

0.50

0.75

0.65

0.55

0.45

(4.00)

(5.00)

(6.00)

(7.00)

(3.50)

(2.50)

(1.50)

(4.50)

(5.50)

(6.50)

(7.50)

(3.00)

(2.00)

0.90

0.85

1.00

0.95

1.10

1.05

1.20

1.15

1.30

1.25

0.40

0.35

0.30

0.25

0.20

1600 WALL SYSTEM®1NOVEMBER, 2010

THERMAL CHARTS

Note:Valuesinparenthesesaremetric. COG=CenterofGlass. ChartsaregeneratedperAAMA507.

System U-Factor for Vision Glass

COG U-factor

Vision Area / Total Area (%)

Sys

tem

U-F

acto

r (B

tu/h

·ft2 ·

°F)

Sys

tem

U-F

acto

r (W

/m2 ·

°C)

Page 33: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

33

2.00

3.00

4.00

5.00

11.00

15.0019.0030.00

0.70

0.60

0.50

0.40

0.30

0.20

95 90 85 80 75 70

0.65

0.55

0.45

0.35

0.25

0.15

0.05

0.10

1600 WALL SYSTEM®1NOVEMBER, 2010

Note:Valuesinparenthesesaremetric. COG=CenterofGlass. ChartsaregeneratedperAAMA507.

Spandrel R-Value

System U-Factors for Spandrel Glass

Spandrel Area / Total Area (%)

THERMAL CHARTS

Sys

tem

U-F

acto

r (B

tu/h

·ft2 ·

°F)

Page 34: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

34 1600 WALL SYSTEM®1NOVEMBER, 2010

THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

COGSHGC

COG VT

System Visible Transmittance (VT) vs Percent of Vision Area

Vision Area / Total Area (%)

Vision Ares / Total Area (%)

Sys

tem

SH

GC

ChartsaregeneratedperAAMA507.

ChartsaregeneratedperAAMA507.

Sys

tem

VT

Page 35: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

35

0.48

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.61

0.60

0.58

0.56

0.55

0.53

0.51

0.50

0.48

0.47

0.45

0.43

0.42

0.40

0.38

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.67

0.63

0.58

0.54

0.49

0.45

0.40

0.36

0.31

0.27

0.22

0.18

0.13

0.09

0.04

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.69

0.64

0.60

0.55

0.51

0.46

0.42

0.37

0.33

0.28

0.24

0.20

0.15

0.11

0.06

1600 WALL SYSTEM®1NOVEMBER, 2010

nOTE:Forglassvaluesthatarenotlisted,linearinterpolationispermitted.

1.U-FactorsaredeterminedinaccordancewithNFRC100.2.SHGCandVTvaluesaredeterminedinaccordancewithNFRC200.3.Glasspropertiesarebasedoncenterofglassvaluesandareobtainedfromyourglasssupplier.4.OverallU-Factor,SHGC,andVTMatriciesarebasedonthestandardNFRCspecimensizeof2000mmwideby2000mmhigh(78-3/4"by78-3/4").

Thermal Transmittance 1 (BTU/hr•ft2•°F)

SHGC Matrix 2 Visible Transmittance 2

Glass U-Factor 3 Overall U-Factor 4

Glass VT 3 Overall VT 4Glass SHGC 3 Overall SHGC 4

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

Page 36: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

36

0.48(2.73)

0.46(2.61)

0.44(2.50)

0.42(2.39)

0.40(2.27)

0.38(2.16)

0.36(2.05)

0.34(1.93)

0.32(1.82)

0.30(1.71)

0.28(1.59)

0.26(1.48)

0.24(1.37)

0.22(1.25)

0.20(1.14)

0.70

0.80

0.60

0.50

0.75

0.65

0.55

0.45

(4.00)

(4.50)

(3.50)

(3.00)

0.90

0.85

(5.00)

1.00

0.95

(6.00)

1600 WALL SYSTEM®1NOVEMBER, 2010

THERMAL CHARTS

notes for System U-factor, SHGC and VT charts:Forglassvaluesthatarenotlisted,linearinterpolationispermitted.Glasspropertiesarebasedoncenterofglassvaluesandareobtainedfromyourglasssupplier.

Percent of Glass Area = Vision Area/Total AreaDaylight Opening / Projected Area

COGU-factor

1600 System®1 with GLASSventTM - Projecting (Awning - Single)note:Valuesinparenthesesaremetric.COG=CenterofGlass.ChartsaregeneratedperAMMA507

System U-Factor for Vision Glass

Sys

tem

U-F

acto

r (B

tu/h

·ft2 ·

°F)

Sys

tem

U-F

acto

r (W

/m2 ·

°C)

Page 37: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

371600 WALL SYSTEM®1NOVEMBER, 2010

THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Vision Area / Total Area (%)

COGSHGC

Sys

tem

SH

GC

System Visible Transmittance (VT) vs Percent of Vision Area

Vision Area / Total Area (%)

COGVT

Sys

tem

VT

1600 System®1 with GLASSventTM - Projecting (Awning - Single)

Page 38: 1600 CW--- kawneer

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

0

kawneer.com

EC 97911-24

38

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.46

0.43

0.41

0.38

0.35

0.32

0.30

0.27

0.24

0.21

0.18

0.16

0.13

0.10

0.07

0.48

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.87

0.86

0.85

0.84

0.83

0.82

0.81

0.80

0.79

0.78

0.77

0.76

0.76

0.75

0.74

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.42

0.39

0.36

0.33

0.30

0.28

0.25

0.22

0.19

0.17

0.14

0.11

0.08

0.06

0.03

1600 WALL SYSTEM®1NOVEMBER, 2010

nOTE:Forglassvaluesthatarenotlisted,linearinterpolationispermitted.1.U-FactorsaredeterminedinaccordancewithNFRC100.2.SHGCandVTvaluesaredeterminedinaccordancewithNFRC200.3.Glasspropertiesarebasedoncenterofglassvaluesandareobtainedfromyourglasssupplier.4.OverallU-Factor,SHGC,andVTMatriciesarebasedonthestandardNFRCspecimensizeof1200mmwideby1500mmhigh(47-1/4"by59-1/16").

Thermal Transmittance1 (BTU/hr•ft2•°F)

SHGC Matrix 2 Visible Transmittance 2

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

Glass U-Factor 3 Overall U-Factor 4

Glass SHGC 3 Overall Glass U-Factor 4 Glass VT 3 Overall VT 4

1600 System®1 with GLASSventTM - Projecting (Awning - Single)