Ref No: 08-08-11-038 Ref No: projects/south/06-07/CRN 06-07/ New Equipment & Systems Approval - Strail Rubber Level crossing 1. Determination of Need: Presently only 2 modular level crossing systems are approved by ARTC. One is a concrete panel and the other is a steel level crossing surface. Alternatives are required so supply times and most cost efficient prices can be obtained. Strail offers an acceptable alternative for low volume low speed (50Kph) level crossing. Modular systems allow quick and cheap track rectification as the panels can be removed. Normal concrete and bitumen surfaces do not have this advantage. The first crossing proposed to be installed is a double track on the Main South, Kowcumbla Rd, Cootamundra 430.700 Km. Kowcumbla Rd is a tarred main street leading out of town. The road speed is 50 Kph and it is used mainly by cars and some trucks. The road is NOT a B double route. The level crossing is one lane each way and is approximately 9 m wide. Technical details for the Strail Modular panels are attached. 2. Significant Change or Not This change in equipment is assessed as MINOR 3. Review Panel John Cowie - Manager, ISP, Standards and Systems Tim Calver - Standards and Technical Services Engineer Ian Domleo Senior Track and Civil Consultant 4. Approval Approved for use where suitable across the ARTC network. 5. Conditions of Approval Install as per manufacturers instructions 6. Sign off Review Panel: John Cowie per signed original Date 07/08/2006 Tim Calver per signed original Date 07/08/2006 Ian Domleo per signed original Date 07/08/2006

08-08-11-038 strail rubber level crossing - ARTC - … · Strail Rubber Level crossing 1. ... Strail Modular panels are attached. 2. Significant Change or Not This change in equipment

  • Upload
    ngoliem

  • View
    218

  • Download
    1

Embed Size (px)

Citation preview

Page 1: 08-08-11-038 strail rubber level crossing - ARTC - … · Strail Rubber Level crossing 1. ... Strail Modular panels are attached. 2. Significant Change or Not This change in equipment

Ref No: 08-08-11-038

Ref No: projects/south/06-07/CRN 06-07/

New Equipment & Systems Approval -Strail Rubber Level crossing

1. Determination of Need: Presently only 2 modular level crossing systems areapproved by ARTC. One is a concrete panel and the other is a steel levelcrossing surface. Alternatives are required so supply times and most costefficient prices can be obtained. Strail offers an acceptable alternative for lowvolume low speed (50Kph) level crossing. Modular systems allow quick andcheap track rectification as the panels can be removed. Normal concrete andbitumen surfaces do not have this advantage.The first crossing proposed to be installed is a double track on the Main South,Kowcumbla Rd, Cootamundra 430.700 Km. Kowcumbla Rd is a tarred mainstreet leading out of town. The road speed is 50 Kph and it is used mainly bycars and some trucks. The road is NOT a B double route. The level crossing isone lane each way and is approximately 9 m wide. Technical details for theStrail Modular panels are attached.

2. Significant Change or Not

This change in equipment is assessed as MINOR

3. Review Panel

John Cowie - Manager, ISP, Standards and Systems Tim Calver - Standards and Technical Services Engineer Ian Domleo –Senior Track and Civil Consultant

4. Approval

Approved for use where suitable across the ARTC network.

5. Conditions of Approval

Install as per manufacturers instructions

6. Sign offReview Panel:

John Cowie per signed original Date 07/08/2006

Tim Calver per signed original Date 07/08/2006

Ian Domleo per signed original Date 07/08/2006

Page 2: 08-08-11-038 strail rubber level crossing - ARTC - … · Strail Rubber Level crossing 1. ... Strail Modular panels are attached. 2. Significant Change or Not This change in equipment

length of crossing

deflection plate

~yy~"yy ~~-~

~

'!"'=---'-~ - -

~g~wf

¥c -, --,

~d "..?,,~. .I I

.,~"6 --(2)..standard module standard module center module, standard module standard module,.. .,- -

f

r.6)-

.

tie rod

center rod

movement stopper

deflection plate

STRAI L panel

filler block

,g//1

I J

0

III

~

~//1

~~

III

!

~~

h[;

.[(j)

d

~

0Subject to technical alterations

02.03.99/LHA/lndex 8

GUMMIWERK KRAIBURG ELASTIK GmbH, GollstraBe 8, 0-84529 TittmoningPhone +49 8683 701 0, Fax +49 8683 701 126

e-mail: [email protected], Internet: www.kraiburg.com

Page 3: 08-08-11-038 strail rubber level crossing - ARTC - … · Strail Rubber Level crossing 1. ... Strail Modular panels are attached. 2. Significant Change or Not This change in equipment

0~0C-

O0,.:~

LZ

!

,0,000000~

-4

mm

-4oo~a-a-,o000000

L-a.c:5-"Q

j~a.c:u

'" C

:'Va

~

'Vc.-

u c.

.c

" L-L-L-

"C

a. a.

a.a

c:~-

L- c: "

~c.

.-a -

10

il.c....! ~'iV'-~j

d

Cl'

c2GJ

L"';;;G

JtOc..-

-GJ-

-GJ-

to-tO."'L

41>00L-a-

4141a-a-jC'V

'V...::

ee0'"~~=~i

conkb
Typical only
Page 4: 08-08-11-038 strail rubber level crossing - ARTC - … · Strail Rubber Level crossing 1. ... Strail Modular panels are attached. 2. Significant Change or Not This change in equipment

~

Inl

~

~

CD LX

)

L.I -u

~

C5

:zl:JV

>LLJ0

U.J

w

EE,

I ~2

~~

--Co

~

~-o

~

.",:!

c"t .,

'"~

E

1 I

on

..2: IC~~ ..,g-"~

,~g.

" v=..~

,~-"0-.."O

~~..-

..-;:"O

"O~

~"v

~~

..3~

~-=

~c"c.._~e ~~

c

~~

a.O

v;:..~

O..c.....cc..~

~is!'..,

~~~

""'-O

",-C

.,..oe

1!!! -}.5

...:g"g.c.2.]i

il~1

Ij£j.i-

!I 000N~=:!

-<0:t-V>I

~i~I J_I

li'~f

....0.0.0"'M

~..~>0e..f!ij

..

III..I:

, ~.c

",~

:~

..IT

~

I Ijl

~~"0~l-.t

."

'"'i.ic:OJ

-5'0;

" c:~"Q.

QI

0'.2!

i,j>-:;:.0>

-~-' ~E~:;;O

J~

?-,'"~

conkb
Typical only