003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department Design Team Supervision Implant Lab, Marketing PM Production/Distribution Marketing & Planning Team Date of Publication 2014. Publisher Osstem Implant 8th FL, World Meridian II, 123, Gasan digital 2-ro, Geumcheon-gu, Seoul, Korea Phone +82.2.2016.7000 Fax +82.2.2016.7001 www.osstem.com

003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

003012016064

INTRODUCTION

CONTENTS

US SYSTEM

REFERENCE

Osstem Implant 2014-15 Comprehensive Catalog

Overall Planning/Editing PR Department Design Team

Supervision Implant Lab, Marketing PM

Production/Distribution Marketing & Planning Team

Date of Publication 2014.

Publisher Osstem Implant

8th FL, World Meridian II, 123, Gasan digital 2-ro,

Geumcheon-gu, Seoul, Korea

Phone +82.2.2016.7000

Fax +82.2.2016.7001

www.osstem.com

Page 2: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

"Osstem - FutureTechnology and

Superior Quality"Products that dentists can trust.

That is the mission of Osstem Implant.

We deeply appreciate all of our customers

who use our products.

We deeply appreciate all of our customers who use our products.With population aging, rising incomes, and increased interest in healthand aesthetics, implants have become an essential treatment indentistry around the world.Today, implants are well-known as a safe and effective treatmentoption, and the leading treatment option for patients with no teeth.To satisfy this global trend, Osstem has invested heavily in R&D andcontinuously promotes innovative products, resulting in it becoming aglobal leader in technology and product quality.Osstem is releasing new products including TSIII CA, TSIII BA, SSIIIHA, and MS SA, and is strengthening its product line-up in order toenable application in a variety of clinical cases. Other products to bereleased that will enable safe, easy implant procedures includeSMARTbuilder, AutoBone collector, 123 KIT, and ESSET KIT.

TSIII CA in particular is expected to become a leading product in theglobal implant market after launching as a groundbreaking product withsuperior hydrophilic properties capable of at least 30% greater fusionthan ordinary SA products due to its calcium ion solution encapsulation.Also, to improve our customers' convenience and foster reasonablepurchasing, we have opened an online store, DenALL (www.denall.com),where dentistry materials can be purchased affordably and conveniently.Osstem leads the way in superior product quality and exports to over50 countries including the USA, China, Japan, Germany, and India, andis the first company in Korea to record implant sales of over 30 millionproducts and overseas subsidiary sales of over 100 billion won.

Osstem Implant CEOGyu-ok Choi (DDS, Ph.D)

Page 3: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

20062006 ssia (Moscow)ssia (MoRusRus

( (Esch (Esc )hborn)

20112011 zakhstan (Almaty)maty)zakhstan (Almaty)KazK

2011201111 BanBangladeshglgla h (Dhaka)(Dh )ei)n (Taipeanwaan (Tanwaaa )ei)Taipe )i)T in (Tanwa (TaTaiwTaiwTaiwT i

2006

20062006

20132013320101 ey (Isrkey (Istanbul)ul)key (Tuur 1997

2011

2006

2007 Australia (SSydney)

2011 nada (Vancouver)Ca

2006 aUSA (Philadelphia)delphia)hia)

201120 exico (Guadalajara)exico (GuadMeMe

12

01 OSSTEM Co., Ltd.Founded

Launched "Doobunae"(health insurance claimingsoftware)

10

06 Launched "Hanaro"(dentistry managementsoftware)

Acquired Korean companySumin ComprehensiveDental Materials

199701 Obtained CE-0434

certification

03 Established AICTraining Center

200103 Changed company name to

Osstem Implant Co., Ltd.

04 Obtained GOST-Rcertification in Russia

12 Established the firstincorporation stage ofoverseas subsidiaries in 12countries

200602 Listed on KOSDAQ

stock exchange andbegan trading

06 Obtained GOST-Rcertification in Russia

12 Selected next-generation productsObtained certificationfrom Australia'sTherapeutic GoodsAdministration

200701 Established Osstem's

osteology researchcenter

12 Selected as a NationalStrategic LeadingTechnology Company

200803 Launched TSIII SA implant

06 Launched TSIII HA implant

08 Selected as WPMBiomedical National PolicyCompany

12 Exceeded 10,000 dentistrysoftware members

2010

10 Obtained permissionfrom Japan's Ministry ofHealth, Labor, andWelfare to produce andsell medical devices

200905 Selected as a WorldClass

300 business

2014

06 Selected Osstem ImplantResearch Center as an ATC(Superior TechnologyResearch Center)

07 Selected as a worldchampion business

10 Obtained Health Canadacertification

12 Launched K2 unit chairSelected as "Global First-Class Product"

201101 Launched Osstem's

xenograft "A-Oss"09 Launched K3 unit chair

10 Selected as a hiddenchampion business

2013

06 Launched TSIII CA implant

07 Established Osstem MedicalEquipment Research Center

2012

200001 Established Osstem

Implant Research Center

08 Obtained US FDAcertificationLaunched USII implant

10 Launched SSII implant

2002

Page 4: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

Osstem Implant,the leader in popularizing implants in Korea!

We stand out with our passion for strategic

R&D and best products, creating globally

trend-setting implants.

Submerged type implant with an Internal hex 11taper connection structure

Connection type and color - Mini/Regular

Highest initial stability in soft bone by using upper-section small thread

Corkscrew thread & cutting edge- Easy path adjustment through a superior self-threading

effect- Acquires insertion torque with an increase in soft bone

initial stability and without deviation according to thedrill diameters

The various body shape options are available accordingto the bone and patient's clinical condition- TSII (straight body): Easily adjustable insertion depth- TSIII (1.5 taper body): Able to acquire the initial stability

needed for immediate loading even in soft bone- TSIV (6 taper body): Able to acquire superior initial

stability only in maxillary sinus and soft bone

Applied Surface - SA/CA/BA/HA

Packaging Color Information for Each System

Non-submerged type implant with anInternal octa 8 taper connectionstructure based on one-time procedures

Connection type and color - Regular/Wide

Corkscrew thread & cutting edge- Easy path adjustment through a superior self-threading

effect- Acquires insertion torque with an increase in soft bone

initial stability and without deviation according to thedrill diameters

The various body shape options are available accordingto the bone and patient's clinical condition- SSII (straight body): Easily adjustable insertion depth- SSIII (1.5 taper body): Able to acquire the initial stability

needed for immediate loading even in soft bone

Applied Surface - SA/CA/HA

Submerged type implant with an external hexconnection structure

Connection type and color- Mini/Regular/Wide/Wide PS

Corkscrew thread & cutting edge- Easy path adjustment through a superior self-threading

effect- Acquires insertion torque with an increase in soft bone

initial stability and without deviation according to thedrill diameters

The various body shape options are available accordingto the bone and patient's clinical condition- USII (straight body): Easily adjustable insertion depth- USIII (1.5 taper body): Able to acquire the initial stability

needed for immediate loading even in soft bone- USIV (6 taper body): Able to acquire superior initial

stability only in maxillary sinus and soft bone

Applied Surface - SA

Page 5: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

US SYSTEM Contents

016USII SAFixture

018USIII SAFixture

020USIV SAFixture

022SimpleMount

022CoverScrew

022 023 025CementAbutment

028 030

031 032 033 034 035FixtureTransferImpressionCoping

036Fixture LabAnalog

036UCLAPolishingProtector

037SmartFitAbutment

038 039

040 044EstheticAbutment

045 045 045

046 046046EstheticPick-upImpressionCoping

047EstheticLabAnalog

047

048 049 049 049 050Esthetic-lowTemporaryCylinder

AngledAbutment

UCLAGoldAbutment

EstheticGoldCylinder

EstheticPlasticCylinder

EstheticTemporaryCylinder

EstheticTransferImpressionCoping

Esthetic-lowAbutment

Esthetic-low GoldCylinder

Esthetic-lowPlasticCylinder

Esthetic-low HealingCap

ZioCeraAngledAbutment

EstheticPolishingProtector

HeadlessCoverScrew

HealingAbutment

UCLANP-CastAbutment

UCLAPlasticAbutment

FixturePick-UpImpressionCoping

ZioCeraAbutment

SafeAbutment

EstheticHealingCap

UCLATemporaryAbutment

057057StandardPick-upImpressionCoping

057 057StandardPolishingProtector

StandardLabAnalog

050050Esthetic-low Pick-upImpressionCoping

051 051Esthetic-lowPolishingProtector

052MultiAngledAbutment

055StandardAbutment

056StandardHealingCap

056 056 056StandardTemporaryCylinder

Esthetic-low LabAnalog

Esthetic-lowTransferImpressionCoping

EstheticPlasticCylinder

059O-ring Abutment

060O-ringRetainerCap Set

060O-ringRetainerSet

060O-ring Set

061LocatorAbutment

062LocatorMaleProcessingKit

062LocatorReplacementMale

062LocatorExtendedReplacementMale

063LocatorBlackProcessingMale

063LocatorBlock OutSpacers

063LocatorImpressionCoping

063LocatorLab Analog

064LocatorCore Tool

064LocatorTorqueDriver

StandardGoldCylinder

StandardTransferImpressionCoping

060O-ring Lab Analog

Page 6: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

FIXTURE COMPONENTS016018020022022022023

USII SA Fixture

USIII SA Fixture

USIV SA Fixture

Simple Mount

Cover Screw

Headless Cover Screw

Healing Abutment

024025028030031032033037038039040042044048052054055058059061

PROSTHETIC FLOW DIAGRAM 1

Cement Abutment

Angled Abutment

UCLA Gold Abutment

UCLA NP-Cast Abutment

UCLA Plastic Abutment

UCLA Temporary Abutment

SmartFit Abutment

ZioCera Abutment

ZioCera Angled Abutment

Safe Abutment

PROSTHETIC FLOW DIAGRAM 2

Esthetic Abutment

Esthetic-low Abutment

Multi Angled Abutment

PROSTHETIC FLOW DIAGRAM 3

Standard Abutment

PROSTHETIC FLOW DIAGRAM 4

O-ring Abutment

Locator Abutment

Page 7: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

016

L

Hex 1.2

L 8.5 10 11.5 13

US2M3508S US2M3510S US2M3511S US2M3513S

L 8.5 107 11.5 13

US2S4008SUS2S4007S US2S4010S US2S4011S US2S4013S

L 8.5 107 11.5 13

US2S4508SUS2S4507S US2S4510S US2S4511S US2S4513S

D Ø3.5P Ø3.5Hex 2.4

D Ø4.0P Ø4.1Hex 2.7

D Ø4.5P Ø4.1Hex 2.7

USII SA Fixture

Submerged type implant with external hex connection structure

Optimum screw thread design for optimum SA surface

Straight body design for easy adjustment of insertion depth

Powerful self-threading effect using corkscrew thread

Recommended insertion torque : 40Ncm 이하

※ In single implant cases for posterior region, use of fixture at least 4.5mm

in diameter is recommended

NoMount fixture order code

: fixture product code (ex : US2R4010S)

Pre-Mounted fixture order code (fixture + mount + cover screw)

: A + fixture product code (ex : AUS2R4010S)

017

PS

L 8.5 1076 11.5 13

US2W5008SUS2W5007SUS2W5006S US2W5010S US2W5011S US2W5013S

L 8.5 1076 11.5 13

US2P5008SUS2P5007SUS2P5006S US2P5010S US2P5011S US2P5013S

D Ø5.0P Ø5.1Hex 3.4

D Ø5.0P Ø5.0Hex 2.7

Short

Short

D

Page 8: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

018 019

L

Hex 1.2

L 8.5 10 11.5 13

US3M3508S US3M3510S US3M3511S US3M3513S

L 8.5 107 11.5 13

US3R4008SUS3R4007S US3R4010S US3R4011S US3R4013S

L 8.5 107 11.5 13

US3R4508SUS3R4507S US3R4510S US3R4511S US3R4513S

D Ø3.5P Ø3.5Hex 2.4

D Ø4.0P Ø4.1Hex 2.7

D Ø4.5P Ø4.1Hex 2.7

L 8.5 1076 11.5 13

US3W5008SUS3W5007SUS3W5006S US3W5010S US3W5011S US3W5013S

L 8.5 1076 11.5 13

US3P5008SUS3P5007SUS3P5006S US3P5010S US3P5011S US3P5013S

D Ø5.0P Ø5.1Hex 3.4

D Ø5.0P Ø5.0Hex 2.7

Short

L 8.5 1076 11.5 13

US3W6008SUS3W6007SUS3W6006S US3W6010S US3W6011S US3W6013S

D Ø6.0P Ø5.1Hex 3.4

Short

L 8.5 1076 11.5 13

US3W7008SUS3W7007SUS3W7006S US3W7010S US3W7011S US3W7013S

D Ø7.0P Ø5.1Hex 3.4

Short

Ultra-wide

USIII SA Fixture

Submerged type implant with external hex connection structure

Optimum screw thread design for optimum SA surface

Taper body design with superior initial stability

Powerful self-threading effect using corkscrew thread

Acquires the initial stability needed in immediate loading even in soft bone

Ultra-wide

In implant cases for posterior tooth extraction and immediate insertion, this

fixture is useful in exchanging a failed implant

With its optimized apex design, capable of extracting a tooth and obtaining

initial stability safely even at the bottom 3mm

Recommended insertion torque : 40Ncm 이하

※ In single implant cases for posterior region, use of fixture at least 4.5mm in

diameter is recommended

NoMount fixture order code

: fixture product code (ex : US3R4010S)

Pre-Mounted fixture order code (fixture + mount + cover screw)

: A + fixture product code (ex : AUS3R4010S)

Short

PS

D

Page 9: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

020 021

USIV SA Fixture

Submerged type implant with external hex connection structure

Optimum screw thread design for optimum SA surface

Fixture for use only in maxillary sinus and soft bone

Powerful self-threading effect using corkscrew thread

Due to sharp apex design, even after D4 bone Ø2.0, Ø3.0mm drilling

implant insertion is possible

Recommended insertion torque : 40Ncm 이하

※ In single implant cases for posterior region, use of fixture at least 4.5mm

in diameter is recommended

※ USIV fixture insertion is recommended at 15 rpm or lower due to large

thread pitch and high insertion speed

NoMount fixture order code (fixture + mount + cover screw)

: fixture product code (ex : US4R4010S)

Pre-Mounted fixture order code (fixture + mount + cover screw)

: A + fixture product code (ex : AUS4R4010S)

L

Hex 1.2

L 8.5 107 11.5 13

US4R4008SUS4R4007S US4R4010S US4R4011S US4R4013S

L 8.5 107 11.5 13

US4R4508SUS4R4507S US4R4510S US4R4511S US4R4513S

L 8.5 107 11.5 13

US4W5008SUS4W5007S US4W5010S US4W5011S US4W5013S

D Ø4.0P Ø4.1Hex 2.7

D Ø4.5P Ø4.1Hex 2.7

D Ø5.0P Ø5.1Hex 3.4

L 8.5 107 11.5 13

US4P5008SUS4P5007S US4P5010S US4P5011S US4P5013S

D Ø5.0P Ø5.0Hex 2.7

PS

D

Page 10: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

022 023

USHAMM

AICM100 AICR100 AICW100 TICW100

D

H

1.1

1.1

USHAMR

USHAMW

HCM100 HCR100 HCW100

Simple Mount

Hex driver : 1.2Recommended tightening torque : 8~10NcmPacking unit : mount + mount screw C = Connection

Mount & Screw

C

CCover Screw

Hex driver : 0.9(mini), 1.2(regular/wide)Recommended tightening torque : 5~8NcmC = Connection

CHeadless Cover Screw

Used when adjacent space is l imited or there is

insufficient gum tissue in the suture area

Hex driver : 0.9(mini), 1.2(regular/wide)Recommended tightening torque : 5~8NcmC = Connection

Healing Abutment

Hex driver : 1.2Recommended tightening torque : 5~8Ncm

D H

Ø 4.0Ø 5.0

AIHM503

AIHM505

-

-

-

-

AIHM403

AIHM405

-

-

2.0 3.0 5.5 7.04.0

D H

Ø 4.1 One Piece

Ø 4.1 Two Piece

Ø 5.0Ø 6.0

AIOHR405

AIHR405

AIHR505

AIHR605

AIOHR407

AIHR407

AIHR507

AIHR607

AIOHR403

AIHR403

AIHR503

AIHR603

-

-

AIHR502

AIHR602

2.0 3.0 5.5 7.0

-

-

AIHR504

AIHR604

4.0

D H

Ø 5.1 One Piece

Ø 5.1 Two Piece

Ø 6.0Ø 7.0Ø 6.0 PS

AIOHW505

AIHW505

AIHW605

AIHW705

TIHW605

-

-

-

-

-

AIOHW503

AIHW503

AIHW603

AIHW703

TIHW603

-

-

AIHW602

AIHW702

2.0 3.0 5.5 7.0

-

-

AIHW604

AIHW704

4.0

Fixture level

PS

Page 11: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

Fixture Transfer Impression Coping

Non-HexHexShort

Fixture Pick-up Impression Coping

Long

025024

Non-HexHex

UCLA TemporaryAbutment

Ti Screw

UCLA Polishing Protector(Only UCLA Abutment)

CementAbutment

Double Hex Hex

AngledAbutment

Non-HexHexNon-HexHex

UCLA PlasticAbutment

Fixture Lab Analog

ZioCera (Angled)Abutment

SmartFitAbutment

Non-HexHexNon-Hex

UCLA Gold/NP-CastAbutment

Hex

SafeAbutment

PROSTHETIC FLOW DIAGRAM 1

Cement / Angled / UCLA / SmartFit /ZioCera / Safe

Cover Screw

022p

Healing Abutment

1.2 Hex Driver

023p

025p

025p 028p 030/031p 032p

036p

034p 035p

036p

033p 037p 038/039p 040p

Fixture Level Impression

Cement Abutment

Ti screw: USABSMT

D Ø4.0

- CAM427 -

G/HHType

7.0

7.0

1.0 2.0 3.0

CAM447

4.0Hex

- CAM427N -

1.0 2.0 3.0

CAM447N

4.0Non-Hex

Used in producing ordinary cement type prosthetics

Gold coloring on gingiva region for aesthetics

1.2 hex driver

Recommended tightening torque : 30 Ncm

Packing unit : abutment + Ti screw

Abutment + Ti screw order code

: product code + TH (ex : CAR525TH) Ti screw

H

G/H

D

Ti screw: ASR200

D Ø4.1

- - CAR437

Type1.0 2.0 3.0

-

4.0Hex

- - CAR437N

1.0 2.0 3.0

-

4.0Non-Hex

1.2 Hex Driver(Mini Only : 0.9 Hex Driver)

Fixture level

H G/H

USII SA

016p

USIII SA

018p

USIV SA

020p

Page 12: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

026 027

Ti screw: ASR200

D Ø5.0

CAR514

CAR515

CAR517

CAR524

CAR525

CAR527

CAR534

CAR535

CAR537

Type

4.05.57.0

1.0 2.0 3.0

CAR544

CAR545

CAR547

4.0Hex

CAR514N

CAR515N

CAR517N

CAR524N

CAR525N

CAR527N

CAR534N

CAR535N

CAR537N

1.0 2.0 3.0

CAR544N

CAR545N

CAR547N

4.0Non-Hex

Ti screw: ASR200

D Ø6.0

CAR615 CAR625 CAR635

Type

5.5

1.0 2.0 3.0

CAR645 CAR615N CAR625N CAR635N CAR645N

4.0Hex

1.0 2.0 3.0 4.0Non-Hex

Ti screw: ASW0200

D Ø6.0

CAW614

CAW615

CAW617

CAW624

CAW625

CAW627

CAW634

CAW635

CAW637

Type

4.05.57.0

1.0 2.0 3.0

CAW644

CAW645

CAW647

4.0Hex

CAW614N

CAW615N

CAW617N

CAW624N

CAW625N

CAW627N

CAW634N

CAW635N

CAW637N

1.0 2.0 3.0

CAW644N

CAW645N

CAW647N

4.0Non-Hex

Ti screw: ASW200

D Ø5.1

- - CAW537

Type

7.0

1.0 2.0 3.0

- - CAW537N -

4.0Hex

1.0 2.0 3.0 4.0Non-Hex

Ti screw: ASW200

D Ø7.0

CAW715 CAW725 CAW735

Type

5.5

1.0 2.0 3.0

CAW745 CAW715N CAW725N CAW735N CAW745N

4.0Hex

1.0 2.0 3.0 4.0Non-Hex

Ti screw: ASR200

D Ø6.0

- TCAW627 -

Type

7.0

1.0 2.0 3.0

TCAW647 - TCAW627N - TCAW647N

4.0Hex

1.0 2.0 3.0 4.0Non-Hex

Ti screw: RASW200

D Ø6.0

- RCAW627 -

TypeR-type

7.0

1.0 2.0 3.0

RCAW647

4.0Hex

Cement Abutment

PS

H G/H H G/H

H G/H

H G/H

H G/H

H G/H

H G/H

Page 13: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

029028

Angled Abutment

AAM4152C AAM4154C AAM4252C AAM4254C

Used when adjusting path of prosthetic is necessary

Through double hex connection, abutment direction limit is

overcome

1.2 hex driver

Recommended tightening torque : Ti screw 30Ncm

Packing unit : abutment + Ti screw

Abutment + Ti screw order code

: product code + TH (ex : AAR5152CTH) Ti screwG/H

12

D

Ti screw: USABSMT

D Ø4.0 G/HAngle

4.02.015°

4.02.025°

AAR5152C AAR5154C AAR5252C AAR5254C

Ti screw: ASR200

D Ø5.0 G/HAngle

4.02.015°

4.02.025°

TAAW6152C TAAW6154C TAAW6252C TAAW6254C

Ti screw: ASR200

D Ø6.0 G/HAngle

4.02.015°

4.02.025°

RAAW6152C RAAW6154C RAAW6252C RAAW6254C

Ti screw: RASW200

D Ø6.0 G/HAngle

4.02.015°

4.02.025°

AAW6152C AAW6154C AAW6252C AAW6254C

Ti screw: ASW200

D Ø6.0 G/HAngle

4.02.015°

4.02.025°

R-type

PS

Fixture level

Page 14: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

030 031

Used when path, aesthetics, or space have limitations

Prosthetic must be produced by casting dental-grade gold alloy

Abutment region fusion range : 1400。C~1450。C

(casting with non-precious metal alloys is incompatible)

1.2 hex driver

Recommended tightening torque : Ti screw 30 Ncm

Packing unit : abutment + Ti screw

Abutment + Ti screw order code

: product code + TH (ex : GCR200TH)

UCLA Gold Abutment

D

Ti screw

GCM200 GCM100

Ti screw: USABSMT

D Ø4.0 Type Non-HexHex

GCR200 GCR100

Ti screw: ASR200

D Ø4.5 Type Non-HexHex

GCW200 GCW100

Ti screw: ASW200

D Ø5.5 Type Non-HexHex

TGCW200 TGCW100

Ti screw: ASR200

D Ø5.5 Type Non-HexHex

RGCW200 RGCW100

Ti screw: RASW200

D Ø6.0 Type Non-HexHex

12

Used when path, aesthetics, or space have limitations

Prosthetic production by casting with dental-grade non-precious

metal alloy

Abutment region fusion range : 1400。C~1550。C

1.2 hex driver

Recommended tightening torque : 30 Ncm

Packing unit : abutment + Ti screw

Abutment + Ti screw order code

: product code + TH (ex : NCR200TH)

UCLA NP-Cast Abutment

D

Ti screw

NCM200 NCM100

Ti screw: USABSMT

D Ø4.0 Type Non-HexHex

NCR200 NCR100

Ti Screw: ASR200

D Ø4.5 Type Non-HexHex

NCW200 NCW100

Ti screw: ASR200

D Ø5.5 Type Non-HexHex

TNCW200 TNCW100

Ti screw: ASR200

D Ø5.5 Type Non-HexHex

12

PS

R-type

PS

Fixture level Fixture level

Page 15: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

032 033

Used when path, aesthetics, or space have limitations

Prosthetic production by casting with dental-grade alloy

(gold, non-precious metals)

Connection region's precision is reduced compared to

UCLA gold abutment

1.2 hex driver

Recommended tightening torque : 30 Ncm

Packing unit : abutment + Ti screw

Abutment + Ti screw order code

: product code + TH (ex : PSR200TH)

UCLA Plastic Abutment

D

Ti screw

PSM200 PSM100

Ti screw: USABSMT

D Ø4.0 Type Non-HexHex

PSR200 PSR100

Ti screw: ASR200

D Ø4.5 Type Non-HexHex

PSW200 PSW100

Ti screw: ASW200

D Ø5.5 Type Non-HexHex

TPSW200 TPSW100

Ti screw: ASR200

D Ø5.5 Type Non-HexHex

RPSW200 RPSW100

Ti screw: RASW200

D Ø6.0 Type Non-HexHex

12

Used in producing temporary prosthetics (Material: Ti Gr-3)

Structure enabling easy customization and minimizing indication

restrictions

1.2 hex driver

Recommended tightening torque : 20 Ncm

Packing unit : abutment + Ti screw

Abutment + Ti screw order code

: product code + TH (ex : TAR200TH)

UCLA Temporary Abutment

D

Ti screw

TAM200 TAM100

Ti screw: USABSMT

D Ø4.0 Type Non-HexHex

TAR200 TAR100

Ti screw: ASR200

D Ø4.5 Type Non-HexHex

TAW200 TAW100

Ti screw: ASW200

D Ø5.5 Type Non-HexHex

TTAW200 TTAW100

Ti screw: ASR200

D Ø5.5 Type Non-HexHex

RTAW200 RTAW100

Ti screw: RASW200

D Ø6.0 Type Non-HexHex

12

PS

R-type

PS

R-type

Fixture level Fixture level

Page 16: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

035034

UCLA Abutment Components

ICPM402L

ICPR502L

ICPW602L

TICPW602

RICPW602

ICPM401L

ICPR501L

ICPW601L

TICPW601

RICPW601

13.5Hex Non-Hex

D LType

Ø 4.0Ø 5.0Ø 6.0Ø 6.0 PS

Ø 6.0 R-type

ICPM402S

ICPR502S

ICPW602S

-

-

ICPM401S

ICPR501S

ICPW601S

-

-

10.5Hex Non-Hex

Fixture Transfer Impression Coping

Takes impression using closed tray

Increased popularity after creating impression with gemstone-shaped structure ( )

1.2 hex driver

Packing unit : hex - impression coping + guide pin

non-hex - impression coping

-

CSR100

-

CSW100

-

-

CSM150

CSR150*

-

CSW150*

TCSW150

RCSW150

-

CSR170

-

-

-

-

D LType

Ø 4.0Ø 5.0Ø 6.0Ø 6.0Ø 6.0 PS

Ø 6.0 R-type

-

ICSR500

-

ICSW600

-

-

-

ICSR500N

-

ICSW600N

-

-

7 10 1715Guide Pin

Hex Non-Hex

ICFM400

ICFR500

ICFR600

ICFW600

TICFW600

RICFW600

ICFM400N

ICFR500N

ICFR600N

ICFW600N

TICFW600N

RICFW600N

12Hex Non-Hex

Fixture Pick-Up Impression Coping

Takes impression using open tray

Superior impression stability with holinone structure

1.2 hex driver

* Label is basic packaging specification

Packing unit : impression coping body + guide pin

Page 17: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

036 037

SmartFit Abutment

CAD/CAM abutment

1.2 hex driver

Recommended tightening torque : 20Ncm(mini), 30Ncm(regular)

Recommended clinical case

- Case where implant insertion area or angle is incorrect (max 30°)

- Multiple cases requiring consistent path and stable support

- Anterior case where aesthetic design is required

- Irregular or exceedingly deep gingiva case

How to Order

- Create order sheet

- Send necessary items for each case to Osstem Implant CAD/CAM center

- Working time : 5~7days

UCLA Abutment Components

Fixture Lab Analog

Achieves fixture in oral cavity on a working model

FAM300

FAR300

FAW300

TFAW300

RFAM300

C

UCLA Polishing Protector

Used to prevent damage to connection part when

polishing after casting a prosthetic

UPCM100

UPCR100

UPCW100

TUPCW100

RUPCW100

C

PS

R-type

PS

R-type

Page 18: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

038 039

ZioCera Abutment

Zirconia material with superior biocompatibility

Advantageous in aesthetic prosthetics due to having similar color

with natural teeth

1.2 hex driver

Recommended tightening torque : Ti screw 30Ncm

Packing unit : abutment + Ti screw

Abutment + Ti screw order code

: product code + TH (ex : ZAR537TH)

Ti screw

G/H

H

D

ZAM5377.0 ZAM557

Ti screw: ASM200

D Ø5.0 G/HH 5.03.0

ZAR5377.0 ZAR557

Ti screw: ASR200

D Ø5.0 G/HH 5.03.0

ZAR6377.0 ZAR657

Ti screw: ASR200

D Ø6.0 G/HH 5.03.0

ZioCera Angled Abutment

Used in producing aesthetic prosthetics with significant path

adjustment

Advantageous in aesthetic prosthetics due to having similar

color with natural teeth

Capable of screw restoration through direct build-up

1.2 hex driver

Recommended tightening torque : 30Ncm(regular)

Packing unit : abutment + Ti screw

Abutment + Ti screw order code

: product code + TH (ex : ZAAR5173TH)Fixture levelFixture level

G/H

D

H

17°

ZAAR51739.0

Ti screw: ASR200

D Ø5.5 G/HH 3.0

9.0 ZAAR6173

Ti screw: ASR200

D Ø6.5 G/HH 5.0

Ti screw

Page 19: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

041040

G / H

H

SFAR514SC

SFAR515SC

SFAR517SC

4.05.57.0

SFAR544SC

SFAR545SC

SFAR547SC

D Ø4.8 G/HH 4.01.0

SFAR524SC

SFAR525SC

SFAR527SC

2.5

SFAW614SC

SFAW615SC4.05.5

SFAW644SC

SFAW645SC

D Ø6.0 G/HH 4.01.0

SFAW624SC

SFAW625SC

2.5

Used in producing single prosthetics for preventing screw

loosening

Prevents rotation of prosthetic with elliptical abutment body

Gold coloring on gingiva region for aesthetics

1.2 hex driver

Recommended tightening torque : 30Ncm

Packing unit : abutment + Ti screw + carrier cap + protect cap

Safe Abutment

D

Fixture level

Page 20: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

043042

PROSTHETIC FLOW DIAGRAM 2

Esthetic / Esthetic-low / Multi Angled

045p

046p 045p

047p

046p

044p

046p

045p

047p

045p

Abutment Level Impression

Ti Screw

2.0 Int.Hex Driver (Regular) Esthetic Healing Cap

Esthetic TransferImpression Coping

EstheticPolishing Protector

EstheticLab Analog

Esthetic Abutment Screw

EstheticTemporary Cylinder

EstheticGold Cylinder

EstheticPlastic Cylinder

Non-HexHex

Non-HexHex Non-HexHex Non-HexHex

Esthetic Pick-up Impression Coping

Esthetic Abutment(Regular Only)

049p

050p 049p

051p

050p

048p 052p

050p

049p

051p

049p

Ti Screw

2.0 Int.Hex Driver (Regular)

2.7 Int.Hex Driver (Wide)Esthetic-low

AbutmentMulti Angled

AbutmentEsthetic-low Healing Cap

Esthetic-low TransferImpression Coping

Esthetic-lowPolishing Protector

Esthetic-lowLab Analog

Esthetic-low Abutment Screw

Esthetic-lowTemporary Cylinder

Esthetic-lowGold Cylinder

Esthetic-lowPlastic Cylinder

Non-HexHex

Non-HexHex Non-HexHex Non-HexHex

Esthetic-low Pick-upImpression Coping

Cover Screw

022p

Healing Abutment

023p

USII SA

016p

USIII SA

018p

USIV SA

020p

Cover Screw

022p

Healing Abutment

023p

USII SA

016p

USIII SA

018p

USIV SA

020p

1.2 Hex Driver1.2 Hex Driver(Mini Only : 0.9 Hex Driver)

1.2 Hex Driver1.2 Hex Driver(Mini Only : 0.9 Hex Driver)

Page 21: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

045044

G/H

1.8

D

EAR100 EAR400

D Ø4.8 G/H 4.01.0

EAR300

3.0

EAR200

2.0

Used in producing screw-retained aesthetic prosthetics

Structure producing prosthetics in cylinder after attaching

abutment in the oral cavity

Compensates the path up to 30°

2.0 internal hex driver (241p)

Recommended tightening torque : 30Ncm

Packing unit : abutment + Ti screw

Abutment + Ti screw order code

: product code + TH (ex : EAR200TH)

Esthetic Abutment

Fixture level

12

12

Esthetic Abutment Components

Esthetic Healing Cap

Used when protecting aesthetic-low abutment in the oral cavity

and minimizing foreign body sensation in patient

1.2 hex driver

Recommended tightening torque : 20Ncm

EHC100

6.0D H

Ø 4.8

Esthetic Gold Cylinder

Prosthetic must be produced by casting dental-grade gold alloy

Cylinder region fusion range : 1400。C~1450。C

(casting with non-precious metal alloys is incompatible)

1.2 hex driver

Recommended tightening torque : 20Ncm

Packing unit : cylinder + Ti screw

Cylinder + Ti screw order Code

: product code + TH (ex : EGC200TH)

EGC200 EGC100

Hex Non-HexD Type

Ø 4.8Ti screw: TS200

Esthetic Plastic Cylinder

Produces prosthetics by casting with dental-grade alloy

(gold, non-precious metals)

Connection region's precision is reduced compared to

gold cylinder

1.2 hex driver

Recommended tightening torque : 20Ncm

Packing unit : cylinder + Ti screw

Cylinder + Ti Screw order code

: product code + TH (ex : ETT200TH)

EPS200 EPS100

Hex Non-HexD Type

Ø 4.8Ti screw: TS200

Page 22: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

046 047

Esthetic Temporary Cylinder

Used in producing temporary prosthetic with aesthetic

abutment (Material: Ti Gr-3)

Structure allows for easy customization and

minimization of indication constraints

1.2 hex driver

Recommended tightening torque : 20Ncm

Packing unit : cylinder + Ti screw

Cylinder + Ti screw order code

: product code + TH (ex : ETT200TH)

ETT200 ETT100

Hex Non-HexD Type

Ø 4.8Ti screw: TS200

Esthetic Transfer Impression Coping

Takes impression using closed tray

ETR100

8.0D H

Ø 4.8

D L

Ø 4.8 ESR200 ESR100

Hex Non-Hex

Esthetic Pick-up Impression Coping

Takes impression using open tray

Superior impression stability with holinone structure

* Label is basic packaging specification

Packing unit : impression coping body + guide pin

GP100 GP150* GP170

10 17

GP200

2015Guide Pin

12

Esthetic Abutment Components

Esthetic Lab Analog

Achieves aesthetic abutment of the oral cavity on a

working model

ERR300

D

Ø 4.8

Esthetic Polishing Protector

Used with the goal of preventing damage to the connection

area of cylinder when polishing after casting the prosthetic

EPCR100

D

Ø 4.8

Page 23: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

048 049

Esthetic-low Abutment

Used when gap between opposing teeth is

lower than aesthetic abutment

Path compensation up to 48。

2.0(regular), 2.7(wide) internal hex driver (241p)

Recommended tightening torque : 30Ncm

Packing unit : abutment + Ti screw

Abutment + Ti screw order code

: product code + TH (ex : MER200TH)

D

G/H

MER100 MER400

D Ø4.8 G/H 4.01.0

MER300

3.0

MER200

2.0

MEW100 MEW400

D Ø5.5 G/H 4.01.0

MEW300

3.0

MEW200

2.0

TMEW100 TMEW400

D Ø5.5 G/H 4.01.0

TMEW300

3.0

TMEW200

2.0PS

Fixture level

Esthetic-low Healing Cap

Used when protecting aesthetic-low abutment in the oral

cavity and minimizing foreign body sensation in patient

1.2 hex driver

Recommended tightening torque : 20NcmMHCR100

MHCW100

6.0D H

Ø 4.8Ø 5.5/Ø 5.5 PS

Esthetic-low Gold Cylinder

Prosthetic must be produced by casting dental-grade

gold alloy

Cylinder region fusion range : 1400。C~1450。C

(casting with non-precious metal alloys is incompatible)

1.2 hex driver

Recommended tightening torque : 20Ncm

Packing unit : cylinder + Ti screw

Cylinder + Ti screw order code

: product code + TH (ex : MGR200TH)

MGR200

MGW200

MGR100

MGW100

Hex Non-HexD Type

Ø 4.8Ø 5.5/Ø 5.5 PS

Ti screw: MTS200 (Ø 4.8): WTS200 (Ø 5.5 /Ø 5.5PS)

Esthetic-low Plastic Cylinder

Prosthetic production by casting with dental-grade alloy

(gold, non-precious metals) after customization

Lower precision in connection area compared to gold cylinder

1.2 hex driver

Recommended tightening torque : 20Ncm

Packing unit : cylinder + Ti screw

Cylinder + Ti screw order code

: Product code + TH (ex : MEPR200TH)

MEPR200

MEPW200

MEPR100

MEPW100

Hex Non-HexD Type

Ø 4.8Ø 5.5/Ø 5.5 PS

Ti screw: MTS200 (Ø 4.8): WTS200 (Ø 5.5 /Ø 5.5PS)

12

12

Page 24: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

050 051

Esthetic-low Abutment Components

Esthetic-low Temporary Cylinder

Used in producing temporary prosthetics (Material: Ti Gr-3)

Structure enabling easy customization and minimizing

indication restrictions

1.2 hex driver

Recommended tightening torque : 20Ncm

Packing unit : cylinder + Ti screw

Cylinder + Ti screw order code

: product code + TH (ex : MTR200TH)

MTR200

MTW200

MTR100

MTW100

Hex Non-HexD Type

Ø 4.8Ø 5.5/Ø 5.5 PS

Ti screw: MTS200 (Ø 4.8): WTS200 (Ø 5.5 /Ø 5.5PS)

Esthetic-low Transfer Impression Coping

Takes impression using closed tray

Ø 4.8Ø 5.5/Ø 5.5 PS

Ø 4.8Ø 5.5/Ø 5.5 PS

MTTR100

MTTW100

8.0D H

D L

MSR200

MSW200

MSR100

MSW100

Hex Non-Hex

Esthetic-low Pick-up Impression Coping

Takes impression using open tray

Superior impression stability with holinone structure

*Label is basic packaging specification

Packing unit : impression coping body + guide pin

GP100

GPW100

GP150*

GPW150*

GP170

-

10 17

GP200

-

2015Guide Pin

12

Esthetic-low Lab Analog

Achieves aesthetic abutment of the oral cavity on a

working model

MERR300

MERW300

D

Ø 4.8Ø 5.5/Ø 5.5 PS

Esthetic-low Polishing Protector

Used with the goal of preventing damage to the

connection area of cylinder when polishing after casting

the prosthetic

MPCR100

MPCW100

D

Ø 4.8Ø 5.5/Ø 5.5 PS

Page 25: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

052 053

Multi Angled Abutment

Used in implant path compensation in screw retained multiple case

Up to 60。path compensation (two implant standard)

Prosthetic production using US aesthetic-low cylinder(non-hex)

Recommended tightening torque : 20Ncm(mini), 30Ncm(regular)

Packing unit : multi angled abutment + Ti screw

Abutment + Ti screw order code

: product code + TH (ex : US17MAR4830TH)Fixture level

G/H

A

D

Ti screw

Ti screw: USMABSM

D Ø4.8

US17MAM4820 US17MAM4830 -

H/GAngle

2.0 3.0 4.0

- - -

3.0 4.0 5.017。 30。

Ti screw: USMABSR

D Ø4.8

US17MAR4820 US17MAR4830 US17MAR4840

H/GAngle

2.0 3.0 4.0

US30MAR4830 US30MAR4840 US30MAR4850

3.0 4.0 5.017。 30。

Page 26: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

055054

PROSTHETIC FLOW DIAGRAM 3

Standard

056p

056p 056

057p057p

057p 057p

056p

056p

Abutment Level Impression

Ti Screw

2.0 Int.Hex Driver (Regular)

2.7 Int.Hex Driver (Wide)Standard Abutment

(Regular Only)

Standard Healing Cap

Standard Abutment Screw

Standard Temporary Cylinder

Standard Polishing Protector

Standard LabAnalog

Standard Gold Cylinder Standard Plastic Cylinder

Standard Pick-upImpression Coping

Standard TransferImpression Coping

Standard Abutment

Used in producing bridge prosthetics when requiring

hybrid type denture or hygiene management

Advantageous in oral hygiene after producing prosthetic

along gum line

2.0 internal hex driver (241p)

Recommended tightening torque : 30Ncm

Packing unit : abutment + Ti screw

Abutment + Ti screw order code

: product code + TH (ex : SAR300TH)

D

H

SAR300 SAR850

D Ø4.5 G/H 8.5

SAR700

7.03.0

SAR550

5.5

SAR400

4.0

Fixture level

Cover Screw

022p

Healing Abutment

023p

USII SA

016p

USIII SA

018p

USIV SA

020p

055p

1.2 Hex Driver1.2 Hex Driver(Mini Only : 0.9 Hex Driver)

Page 27: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

057056

Standard Abutment Components

Standard Healing Cap

Used when protecting standard abutment in the oral cavity

and minimizing foreign body sensation in patient

1.2 hex driver

Recommended tightening torque : 20Ncm SHC100

3.5D H

Ø 4.5

Standard Gold Cylinder

Prosthetic must be produced by casting dental-grade gold alloy

Cylinder region fusion range : 1400。C~1450。C

(casting with non-precious metal alloys is incompatible)

1.2 hex driver

Recommended tightening torque : 20Ncm

Packing unit : cylinder + EbonyGold screw

Cylinder + EbonyGold screw order code

: product code + WH (ex : SGC300WH)

SGC300 SGC400

11 12D H

Ø 4.5Ti screw: TS200W (Ø 4.5)

Esthetic Plastic Cylinder

Recommended tightening torque : 20Ncm

1.2 hex driver

Prosthetic production by casting with dental-grade alloy

(gold, non-precious metals)

Lower precision in connection area compared to gold cylinder

Packing unit : cylinder + Ti screw

Cylinder + Ti screw order code

: product code + TH (ex : SPS100TH)

SPS100

12D H

Ø 4.5Ti screw: TS200 (Ø 4.5)

Standard Temporary Cylinder

Used in producing temporary prosthetic with standard

abutment (Material: Ti Gr-3)

Structure enabling easy customization and minimizing

indication restrictions

1.2 hex driver

Recommended tightening torque : 20Ncm

Packing unit : cylinder + Ti screw

Cylinder + Ti screw order code

: product code + TH (ex : SPS100TH)

STT100

12D H

Ø 4.5Ti screw: TS200 (Ø 4.5)

Standard Transfer Impression Coping

Takes impression using closed tray

STR100

8.0D H

Ø 4.5

Standard Lab Analog

Achieves standard abutment of the oral cavity on a working

model

SPR300

D

Ø 4.5

Standard Polishing Protector

Used with the goal of preventing damage to the connection

area of cylinder when polishing after casting the prosthetic

SPCR100

D

Ø 4.5

D L

Ø 4.5 SSR100

8.0

Standard Pick-up Impression Coping

Takes impression using open tray

Superior impression stability with holinone structure

*Label is basic packaging specification

Packing unit : impression coping body + guide pin

GP100 GP150* GP170

10 17

GP200

2015Guide Pin

Page 28: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

058 059

PROSTHETIC FLOW DIAGRAM 4

O-ring / LocatorOverdenture

O-ring Lab Analog

Locator Impression Coping

Locator Lab Analog

O-ring Abutment Driver

O-ring

Cap Type

Open Type

O-ring System

Spacer & Male Cap

Male Extended Male

Multi Tool

O-ring Abutment Locator Abutment Locator Torque Driver

059p

063p

063p

061p

060p

060p 060p

064p

064p

O-ring Abutment

Used in creating stud type overdenture prosthetics

Compensates the path up to 20。

Uses O-ring abutment driver (AORD)

Recommended tightening torque : 30Ncm

D

G/H

3.4

G/H 2.0 4.03.0 5.0 6.0

OAA200 OAA300 OAA400 OAA500 OAA600

G/H 2.0 4.03.0 5.0 6.0

OAAW200 OAAW300 OAAW400 OAAW500 OAAW600

D Ø5.0

D Ø5.6

Fixture level

063p

062p 062p

Cover Screw

022p

Healing Abutment

023p

USII SA

016p

USIII SA

018p

USIV SA

020p

1.2 Hex Driver1.2 Hex Driver(Mini Only : 0.9 Hex Driver)

Page 29: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

060 061

O-ring Abutment Components

Achieves low vertical dimension, stability, and various attachments

with retention

Possible path compensation up to40。(two implant standard)

Tightening by using a locator torque driver

Recommended tightening torque : 30Ncm

Locator Abutment

D

1.5

G/H

G/H 1.0 3.02.0 4.0 5.0

HULCA3510M HULCA3520M HULCA3530M HULCA3540M HULCA3550M

D Ø3.5

G/H 1.0 3.02.0 4.0 5.0

HULCA4010R HULCA4020R HULCA4030R HULCA4040R HULCA4050R

D Ø4.1

G/H 1.0 3.02.0 4.0 5.0

HULCA5010W HULCA5020W HULCA5030W HULCA5040W HULCA5050W

D Ø5.0

Fixture level

OAL

RS01

O-ring Retainer Set

Advantageous when occlusal clearance is low

compared to retainer cap

Packing unit : retainer + o-ring

O-ring Lab Analog

Achieves O-ring abutment of the oral cavity on a

working model

RCS01

O-ring Retainer Cap Set

Used in creating stud type overdenture prosthetics

Packing unit : retainer cap + o-ring

OAON01S

O-ring Set

Packing unit : 5ea

Page 30: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

062 063

Locator Abutment Components

LMPS

LRM06S

LRM12S

LRM22S

Locator Male Processing Kit

Component

- Block out spacer / denture cap connected black

processing male

- Replacement male blue/pink/clear

Used after selecting retention males that are appropriate

for the case

Exchanged with male using a locator core tool

Packing unit : 2set

Locator Replacement Male

Retention: Approximately 6N

0。~20。paths (two implant standard)

Packing unit : blue replacement male 4ea

Retention: Approximately 12N

0。~20。paths (two implant standard)

Packing unit : pink replacement male 4ea

Retention: Approximately 22N

0。~20。paths (two implant standard)

Packing unit : clear replacement male 4ea

Locator Extended Replacement Male

Retention: Approximately 6N

20。~40。paths (two implant standard)

Packing unit : red extended replacement male 4ea

Retention: Approximately 12N

20。~40。paths (two implant standard)

Packing unit : green extended replacement male 4ea

LEM06S

LEM12S

Locator Black Processing Male

Used in lab. process

Packing unit : 4ea

LBPS

Locator Block Out Spacers

Gap sealing component between denture cap and abutment

Packing unit : 20ea

LBSS

Locator Impression Coping

Used in taking impressions after attaching locator abutment

Packing unit : 4ea

LICS

Locator Lab Analog

Achieves locator abutment on the model

Packing unit : 4ea

LAL40S

Page 31: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

065064

Locator Abutment Components

TWLDSK TWLDLK

Locator Core Tool

Used in attaching and changing replacement males

LCCT

Short LongLocator Torque Driver

Used in locator abutment tightening

Type

Page 32: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

067066

Osstem Implant Key References

Clinic

No. Title Reference / Author

1 Retrospective clinical study of new tapered design implantsin maxillary posterior areas

Oral Biology Research. 2013; 37(2):105-111

/ Young-Kyun Kim et al.16 Evaluation of sinus bone resorption and marginal bone loss after

sinus bone grafting and implant placementOral Surg Oral Med Oral Pathol Oral Radiol

Endod. 2009;107:e21-8

/ Young-Kyun Kim et al.

17 Evaluation of peri-implant tissue response according to thepresence of keratinized mucosa

Oral Surg Oral Med Oral Pathol OralRadiol

Endod. 2009;107:e24-8

/ Young-Kyun Kim et al.

18 Study on radiographic evaluation of marginal bone loss aroundosseonintegrated implant after functional loading

J Kor Oral Maxillofac Surg. 2009;35:240-7

/ Young - Deok, Chee

19 Four-year survival rate of RBM surface internal connection non-submerged implants and the change of the peri-implant crestal bone

J Korean Assoc Maxillofac Plast Reconstr

Surg. 2009;31(3):237-42

/ Sok-Min Ko et al.

2 A randomized controlled clinical trial of two types of tapered implantson immediate loading in the posterior maxilla and mandible

Int J Oral Maxillofac Implants.

2013 Nov-Dec;28(6):1602-11 (IF 1.908)

/ Young-Kyun Kim et al.

3 Bony window repositioning without using a barrier membranein the lateral approach for maxillary sinus bone grafts:clinical and radiologic results at 6 months.

Int J Oral Maxillofac Implants.

2012 27:211-217

/ Chang-Joo Park et al.

4 A relaxed implant bed: implants placed after two weeks ofosteotomy with immediate loading: a one year clinical trial.

J Oral Implantol. 2012 Apr;38(2):155-64

/ Bansal J et al.

5 A multicenter prospective study in type IV bone of a singletype of implant

Implant Dent. 2012 Aug;21(4):330-34

/ Su-Gwan Kim et al.

6 Comparison of clinical outcomes of sinus bone graft with simultaneousimplant placement: 4-month and 6-month final prosthetic loading

Oral Surg Oral Med Oral Pathol Oral Radiol

Endod. 2011 Feb;111(2):164-9

/ Young-Kyun Kim et al.

7 Prospective study of tapered resorbable blasting media surfaceimplant stability in the maxillary posterior area

Oral Surg Oral Med Oral Pathol Oral Radiol

Endod. 2012 Feb 28. [Epub ahead of print]

/ Young-Kyun Kim et al.

8 A 1-year prospective clinical study of soft tissue conditions and marginalbone changes around dental implants after flapless implant surgery

Oral Surg Oral Med Oral Pathol Oral Radiol

Endod. 2011 Jan;111(1):41-6

/ Byung-Ho Choi et al.

9 Evaluation of peri-implant tissue in nonsubmerged dentalImplants:a multicenter retrospective study

Clin Implant Dent Relat Res.

2011 Dec;13(4):324-9

/ Young-Kyun Kim et al.

Biology

No. Title Reference / Author

1 Experiment study of bone response to hydroxyapatite coatingimplants: bone-implant contact and removal torque test

Oral Surg Oral Med Oral Pathol Oral Radiol.

2012 Jun 29. [Epub ahead of print]

/ Young-Kyun Kim et al.

2 Experimental study about the bony healing of hydroxyapatitecoating implants

J Kor Oral Maxillofac Surg.

2011;27(4):295-300

/ Young-Kyun Kim et al.

3 The use of autologous venous blood for maxillary sinus flooraugmentation in conjunction with sinus membrane elevation: anexperimental study

Clin. Oral Impl. Res. 2010;21:346-9

/ Byung-Ho Choi et al.

4 Effects of soft tissue punch size on the healing of peri-Implanttissue in flapless implant surgery

Oral Surg Oral Med Oral Pathol Oral Radiol

Endod. 2010;109:525-30

/ Byung-Ho Choi et al.

5 Morphogenesis of the peri-implant mucosa: a comparison betweenflap and flapless procedures in the canine mandible

Oral Surg Oral Med Oral Pathol Oral Radiol

Endod. 2009;107:66-70

/ Byung-Ho Choi et al.

6 A comparative study of two noninvasive techniques to evaluateimplant stability: periotest and osstell mentor

Oral Surg Oral Med Oral Pathol Oral Radiol

Endod. 2009;107:513-8

/ Su-Gwan Kim et al.

7 Influence of abutment connections and plaque control on the initialhealing of prematurely exposed implants: an experimental study in dogs

J Periodontol. 2008;79(6):1070-4

/ Byung-Ho Choi et al.

8 Er:YAG laser irradiated implant surface observation with scanningelectron microscopy

J Korean Assoc Maxillofac Plast Reconstr

Surg. 2008;30(6):540-5

/ Seung-Ki Min et al.

9 The effect of surface treatment of the cervical area of implant onbone regeneration in mini-pig

J Kor Oral Maxillofac Surg. 2008;34:285-92

/ Hong-Ju Park et al.

10 A relaxed implant bed: implants placed after two weeks of osteotomywith immediate loading: a one year clinical trial

J Oral Implantol. 2012 Apr;38(2):155-64

/ Bansal J et al.

11 A comparison of implant stability quotients measured usingmagnetic resonance frequency analysis from two directions:prospective clinical study during the initial healing period

Clin. Oral Impl. Res. 2010;21(6):591-7

/ Jong-Ho Lee et al.

12 A short-term clinical study of marginal bone level change aroundmicrothreaded and platform-switched implants

J Periodontal Implant Sci. 2011;41:211-217

/ Kyoo-Sung Cho et al.

13 A randomized clinical one-year trial comparing two types ofnonsubmerged dental implant

Clin. Oral Impl. Res. 2010;21(2):228-36

/ Jong-Ho Lee et al.

14 Short-term, multi-center prospective clinical study of short implantsmeasuring less than 7mm

J Kor Dent Sci. 2010;3(1):11-6

/ Young-Kyun Kim et al.

15 Evaluation of peri-implant tissue in nonsubmerged dentalImplants:a multicenter retrospective study

Oral Surg Oral Med Oral Pathol Oral Radiol

Endod. 2009;108(2):189-95

/ Young-Kyun Kim et al.

Page 33: 003 012 016 064 - OSSTEM · 2015-02-25 · 003 012 016 064 INTRODUCTION CONTENTS US SYSTEM REFERENCE Osstem Implant 2014-15 Comprehensive Catalog Overall Planning/Editing PR Department

069068

10 Histologic and histomorphometric evaluation of early andimmediately loaded implants in the dog mandible

J Biomed Mater Res A. 2008;86:1122-7

/ Su-Gwan Kim et al.

11 Effects of different depths of gap on healing of surgically createdcoronal defects around implants in dogs: a pilot study

J Periodontol. 2008;79(2):355-61

/ June-Sung Shim et al.

12 Comparative study of removal effect on artificial plaque from RBMtreated implant

J Korean Assoc Maxillofac Plast Reconstr

Surg. 2007;29(4):309-20

/ Hee-Jyun Oh et al.

Biomechanics

No. Title Reference / Author

1 Evaluation of the correlation between insertion torque andprimary stabilityof dental implants using a block bone test

J Periodontal Implant Sci. 2013;43:41-46

/ Ki-Tae Koo et al.

2 Self-cutting blades and their influence on primary stability oftapered dental implants in a simulated low-density bone model:a laboratory study

Oral Surg Oral Med Oral Pathol Oral Radiol

Endod. 2011;112:573-580

/ Young-Jun Lim et al.

3 Variation in the total lengths of abutment/implant assemblies generatedwith a function of applied tightening torque in external and internalimplant-abutment connection

Clin. Oral Impl. Res. 2011;22:834-9

/ Ki-Seong Kim et al.

4 Effect of impression coping and implant angulation on the accuracyof implant impressions: an in vitro study

J Adv Prosthodont. 2010;2(4):128-33

/ Seung-Geun Ahn et al.

5 Influence of implant diameter and length changes on initial stability J Kor Acad Prosthodont. 2009;47:335-41

/ Chang-Mo Jeong et al.

6 Mechanical strength of zirconia abutment in implant restoration J KASFO. 2009;25(4):349-60

/ Young-Chan Jeon et al.

7 Heat transfer to the implant-bone interface during preparation ofzirconia/alumina complex abutment

Int J Oral Maxillofac Implants.

2009;24(4):679-83

/ Yong-Geun Choi et al.

8 Fatigue fracture of different dental Implant system under cyclic loading J Kor Acad Prosthodont.

2009;47(4):424-34

/ In-Ho Cho et al.

9 Effect of tightening torque on abutment-fixture joint stability using3-dimensional finite element analysis

J Kor Acad Prosthodont.

2009;47(2):125-35

/ Chang-Mo Jeong et al.

10 The effect of various thread designs on the initial stability of taperimplants

J Adv. Prosthodont. 2009;1:19-25

/ Young-Jun Lim et al.

11 Influence of tungsten carbide/carbon coating of implant-abutmentscrew on screw loosening

J Kor Acad Prosthodont.

2008;46(2):137-47

/ Chang-Mo Jeong et al.

2013.02 ver.4.0 Disposable, re-use prohibited, medical applianceUser Manual

Osstem Implant product informationOsstem Implant dental fixtures and products are manufactured using medical gradeTitanium. Osstem Implant abutments, denture material and surgical tools are onlycompatible with Osstem fixtures. For more detailed information about each product,please refer to the user manuals, catalogs or please visit our corporate website(www.osstem.com). Please check all product labels for product codes,specifications, manufactured dates and expiration dates.

SterilityFixtures, cover screws and healing abutments are cleansed and gamma-sterilized.These products are disposable sterile medical appliances, and must be used in a sterilefield. If the package is damaged or has expired, it must not be used. If the productpackage has been opened but not used, there is a risk of contamination and it is notrecommended that the product resterilized and therefore should be discarded.

Storage conditionsStore all products in a dry place at room temperature (30oC). Avoid direct sunlight.

General precautionsDental implant surgery require proper and formal training and education.

Cautions before dental surgeryBefore dental implant surgery, a through patient health history review, oral andradiographic examinations must be completed to determine bone quality and propertreatment planning.

Cautions during dental implant surgeryOsstem Implant System are for single or two stage dental implant procedures. Inorder to minimize damage to the patient's tissue, special attention to temperature,surgical lesions and eliminating all sources of contamination and infection areneeded. Any deviation from the standard surgical protocol increases the risk offailure. When inserting the dental implant, sufficient cooling must be introduced(water or saline) and excessive torque (greater than 55Ncm) can result in dentalimplant fracture or possibly bone necrosis. Placing dental implants greater than 300has a very high risk of implant fracture. Direct pressure to the fixture should beavoided right after surgery. Immediate or delayed loading of the fixture must bedetermined after proper examination of the patient's bone condition and initialstability after placement.

"Mini" implants or implants with a diameter less than 4.0mm are not recommendedfor the posterior region.

Ultra-wide dental implants are recommended for the posterior region but should notbe used with angled abutments. If considering an Ultra-wide dental implant, properradiographic evaluation must be made to determine the bone mass and potentialanatomical restrictions. Short dental implants (diameter greater than 5mm andshorter than 7mm) are only used for the posterior region. The clinician must

thoroughly evaluate the patient's condition and recognized the following issues:1) bone loss due to peri-implantitis, 2) changes to the dental implant condition,3) proper osseointegration determined by a x-ray examination. If there is movementor if there is bone loss more than 50%, removing the dental implant should be acourse of action. Wide diameter implants should be performed as a two stagesurgery. Sufficient healing time must be given before splinting with other implants orwhen loading. Immediate loading is not recommended.

Take care when placing dental implants with HA coating. The coating is prone tocracking or fracturing under high torque, therefore hard bone should be avoided andbe inserted under 35Ncm of force.

CA and SOSI treated dental implants are encased in a solution to prevent the chemicallytreated surface from reacting with air. After removing the CA or SOSI dental implant,place the implant within 15 minutes to avoid degradation of the surface.

WarningImproper patient selection and treatment planning may result in dental implant failureor loss of bone. Osstem Implants must not be used for purpose other thanprescribed and must not be alter in any shape or form. Implant movement, boneloss, and chronic infections can result in implant failure.

IndicationsOsstem Implant Systems are designed to replace a patient's tooth or teeth. They canbe placed in both the maxillary and submaxillary alveolar bones and after fullosseointegration can be restored prosthetically. Osstem Implant Systems offer bothtemporary and final prosthesis and can be retained by cement, screw, overdentureor fixed bridge.

Side effectsThere are possible side effects after implant surgery (lost of implant stability, damageto dentures). These issues can be due to the lack of bone or poor bone quality, aninfection, patient's poor oral hygiene, non compliance with post op procedures,movement of the implant, degradation of surrounding tissue, or improper placementof the dental implant.

ContraindicationsPatients with the following contraindications are not eligible for dental implants: - Patients with blood clotting issues or issues with wound healing.- Diabetic patients- Patients that smoke or drink excessively- Patient's with compromised immune systems due disease or chemo and radiation

therapy.- Patients with an oral infection or inflammation (improper oral hygiene or teeth

grinding)- Patients with an incurable malocclusion/arthropathia and insufficient arch space.