62
Model H60 Shake Freezer Original Operating Instructions 055165--M 6/01/01 (Original Publication) (Updated 4/16/12)

0 h60 manual

Embed Size (px)

Citation preview

Page 1: 0 h60 manual

Model H60

Shake Freezer

Original Operating Instructions

055165--M

6/01/01 (Original Publication)(Updated 4/16/12)

Page 2: 0 h60 manual

Complete this page for quick reference when service is required:

Taylor Distributor:

Address:

Phone:

Service:

Parts:

Date of Installation:

Information found on the data label:

Model Number:

Serial Number:

Electrical Specs: Voltage Cycle

Phase

Maximum Fuse Size: A

Minimum Wire Ampacity: A

E June, 2001 Taylor (Original Publication)All rights reserved.055165--M

The word Taylor and the Crown designare registered trademarks in the United Statesof America and certain other countries.

Taylor Company750 N. Blackhawk Blvd.Rockton, IL 61072

Page 3: 0 h60 manual

Model H60 Table of Contents

Table of Contents

Section 1 To the Installer 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installer Safety 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Site Preparation 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Air Cooled Units 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Water Connections (Water Cooled Units Only) 2. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Electrical Connections 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Beater Rotation 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Refrigerant 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 2 To the Operator 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Compressor Warranty Disclaimer 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 3 Safety 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 4 Operator Parts Identification 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H60 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H60 Door and Beater Assemblies 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .H60 Syrup Tank -- 045533 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Accessories 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 5 Important: To the Operator 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Symbol Definitions 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Power Switch 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Liquid Crystal Display 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Consistency Control 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Flavor Selector Keypad 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Reset Mechanism 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Operating Screen Descriptions 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Operator Menu 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 6 Operating Procedures 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Assembly 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sanitizing 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Priming 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Daily Closing Procedures 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 4: 0 h60 manual

Table of Contents Model H60

Table of Contents -- Page 2

Daily Opening Procedures 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Syrup System 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Manual Brush Cleaning 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Draining Product From The Freezing Cylinder 31. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Rinsing 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Hopper Cleaning 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Disassembly 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Brush Cleaning 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sanitizing the Syrup System 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 7 Important: Operator Checklist 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

During Cleaning and Sanitizing 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting Bacterial Count 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Regular Maintenance Checks 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Winter Storage 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 8 Troubleshooting Guide 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 9 Parts Replacement Schedule 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 10 Parts List 43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Wiring Diagrams 55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Note: Continuing research results in steady improvements; therefore, informationin this manual is subject to change without notice.

Note: Only instructions originating from the factory or its authorized translationrepresentative(s) are considered to be the original set of instructions.

E June, 2001 Taylor (Original Publication)(Updated April, 2012)All rights reserved.055165--M

The word Taylor and the Crown designare registered trademarks in the United Statesof America and certain other countries.

Taylor Company750 N. Blackhawk Blvd.Rockton, IL 61072

Page 5: 0 h60 manual

1Model H60 To the Installer

110822

Section 1 To the Installer

The following are general installation instructions. Forcomplete installation details, please see the checkoutcard.

Installer Safety

In all areas of the world, equipment should beinstalled in accordance with existing local codes.Please contact your local authorities if you have anyquestions.

Care should be taken to ensure that all basic safetypractices are followed during the installation andservicing activities related to the installation andservice of Taylor equipment.

S Only authorized Taylor service personnelshould perform installation and repairs onthe equipment.

S Authorized service personnel should consultOSHA Standard 29CFRI910.147 or theapplicable code of the local area for theindustry standards on lockout/tagoutprocedures before beginning any installationor repairs.

S Authorized service personnel must ensurethat the proper PPE is available and wornwhen required during installation andservice.

S Authorized service personnel must removeall metal jewelry, rings, and watches beforeworking on electrical equipment.

The main power supply(s) to the machinemust be disconnected prior to performing any repairs.Failure to follow this instruction may result in personalinjury or death from electrical shock or hazardousmoving parts as well as poor performance or damageto the equipment.

Note: All repairs must be performed by anauthorized Taylor Service Technician.

This unit has many sharp edges that cancause severe injuries.

Site Preparation

Review the area where the unit will be installed beforeuncrating the unit. Make sure that all possible hazardsto the user and the equipment have been addressed.

For Indoor UseOnly: This unit is designed to operateindoors, under normal ambient temperatures of70_-75_F (21_-24_C). The freezer has successfullyperformed in high ambient temperatures of104_(40_C) at reduced capacities.

This unit must NOT be installed in an areawhere a water jet or hose can be used. NEVER use awater jet or hose to rinse or clean the unit. Failure tofollow this instruction may result in electrocution.

This unit must be installed on a level surfaceto avoid the hazard of tipping. Extreme care should betaken in moving this equipment for any reason. Two ormore people are required to safely move this unit.Failure to comply may result in personal injury orequipment damage.

Uncrate the unit and inspect it for damage. Report anydamage to your Taylor Distributor.

This piece of equipment is made in the USA and hasUSA sizes of hardware. All metric conversions areapproximate and vary in size.

This machine is designed for indoor use only.

DO NOT install the machine in an area wherea water jet could be used. Failure to follow thisinstruction may result in serious electrical shock.

Page 6: 0 h60 manual

2 Model H60To the Installer

120416

Air Cooled Units

DO NOT obstruct air intake and discharge openings:

Air cooled units require a minimum of 6” (152 mm)minimum air clearance on all sides and 7--1/2” (191mm) minimum on bottom. Minimum air clearancesmust be met to assure adequate air flow for optimumperformance. Failure to allow adequate clearance canreduce the refrigeration capacity of the freezer andpossibly causepermanent damage to the compressor.

Water Connections(Water Cooled Units Only)

An adequate cold water supply must be provided witha hand shut--off valve. On the underside rear of thebase pan, two 3/8” I.P.S. water connections for inletand outlet have been provided for easy hook--up. 1/2”inside diameter water lines should be connected to themachine. (Flexible lines are recommended, if localcodes permit.) Depending on local water conditions, itmay be advisable to install a water strainer to preventforeign substances from clogging the automatic watervalve. There will be only one water “in” and one water“out” connection. DONOT install a hand shut--off valveon thewater “out” line! Water should always flow in thisorder: first, through theautomaticwater valve; second,through the condenser; and third, through the outletfitting to an open trap drain.

A back flow prevention device is requiredon the incoming water connection side. Pleaserefer to the applicable National, State, and local codesfor determining the proper configuration.

Electrical Connections

Each unit requires one power supply for each datalabel on the unit. Check the data label(s) on the freezerfor branch circuit overcurrent protection or fuse, circuitampacity, and other electrical specifications. Refer tothe wiring diagram provided inside of the electrical boxfor proper power connections.

In the United States, this equipment is intended to beinstalled in accordance with the National ElectricalCode (NEC), ANSI/NFPA 70--1987. The purpose ofthe NEC code is the practical safeguarding of personsand property from hazards arising from the use ofelectricity. This code contains provisions considerednecessary for safety. Compliance therewith andproper maintenance will result in an installationessentially free from hazard!

In all other areas of the world, equipment should beinstalled in accordance with the existing local codes.Please contact your local authorities.

FOLLOW YOUR LOCAL ELECTRICAL CODES!

CAUTION: THIS EQUIPMENT MUST BEPROPERLY GROUNDED! FAILURE TO DO SOCAN RESULT IN SEVERE PERSONAL INJURYFROM ELECTRICAL SHOCK!

This equipment is provided with a grounding lugthat is to be properly attached to the rear of the frameby the authorized installer. The installation location ismarked by the equipotential bonding symbol (5021 ofIEC 60417--1) on the removable panel and the frame.

Page 7: 0 h60 manual

3Model H60 To the Installer

S Stationary appliances which are notequipped with a power cord and a plug oranother device to disconnect the appliancefrom the power source must have an all-poledisconnecting device with a contact gap ofat least 3 mm installed in the externalinstallation.

S Appliances that are permanently connectedto fixed wiring and for which leakagecurrents may exceed 10 mA, particularlywhen disconnected, not used for longperiods, or during initial installation, shallhave protective devices such as a GFI toprotect against the leakage of current andbe installed by authorized personnel to thelocal codes.

S Supply cords used with this unit shall beoil-resistant, sheathed, flexible cable, notlighter than ordinary polychloroprene orother equivalent syntheticelastomer-sheathed cord (Code designation60245 IEC 57) installed with the proper cordanchorage to relieve conductors from strain,including twisting, at the terminals andprotect the insulation of the conductors fromabrasion.

Beater Rotation

Beater rotation must be clockwise as viewedlooking into the freezing cylinder.

NOTE: The following procedures shouldbe performed by a trained service technician.

To correct rotation on a three--phase unit, interchangeany two incoming power supply lines at freezer mainterminal block only.

To correct rotation on a single--phase unit, change theleads inside the beater motor. (Follow the diagramprinted on the motor.)

Electrical connections are made directly to theterminal block provided in the main control boxmounted on the right hand side of the freezer.

Refrigerant

In consideration of our environment, Taylorproudly uses only earth friendly HFC refrigerants. TheHFC refrigerant used in this unit is R404A. Thisrefrigerant is generally considered non-toxic andnon-flammable, with an Ozone Depleting Potential(ODP) of zero (0).

However, any gas under pressure is potentiallyhazardous and must be handled with caution.

NEVER fill any refrigerant cylinder completely withliquid. Filling the cylinder to approximately 80% willallow for normal expansion.

Refrigerant liquid sprayed onto the skin maycause serious damage to tissue. Keep eyes and skinprotected. If refrigerant burns should occur, flushimmediately with cold water. If burns are severe, applyice packs and contact a physician immediately.

Taylor reminds technicians to be cautious ofgovernment laws regarding refrigerant recovery,recycling, and reclaiming systems. If you have anyquestions regarding these laws, please contact thefactory Service Department.

WARNING: R404A refrigerant used inconjunction with polyolester oils is extremely moistureabsorbent. When opening a refrigeration system, themaximum time the system is openmust not exceed 15minutes. Cap all open tubing to prevent humid air orwater from being absorbed by the oil.

Page 8: 0 h60 manual

4 Model H60To the Operator

080627

Section 2 To the Operator

The Model H60 shake freezer has been carefullyengineered andmanufactured to give you dependableoperation. This unit, when properly operated andcared for, will produce a consistent, quality product.Like all mechanical products, it will require cleaningand maintenance. A minimum amount of care isnecessary if the operating procedures outlined in thismanual are followed closely.

This Operator’s Manual should be read beforeoperating or performing any maintenance on yourequipment.

Your Taylor freezer will NOT eventually compensatefor and correct any errors during the set--up or fillingoperations. Thus, the initial assembly and primingprocedures are of extreme importance. It is stronglyrecommended that personnel responsible for theequipment’s operation, both assembly anddisassembly, go through these procedures together inorder to be properly trained and to make sure that noconfusion exists.

In the event you should require technical assistance,please contact your local authorized TaylorDistributor.

Note: Warranty is valid only if the parts are authorizedTaylor parts, purchased from an authorized TaylorDistributor, and the required service work is providedby an authorized Taylor service technician. Taylorreserves the right to deny warranty claims onequipment or parts if non--approved parts orrefrigerant were installed in the machine, systemmodifications were performed beyond factoryrecommendations, or it is determined that the failurewas caused by neglect or abuse.

If the crossed out wheeled bin symbol isaffixed to this product, it signifies that this product iscompliant with the EUDirective as well as other similarlegislation in effect after August 13, 2005. Therefore,it must be collected separately after its use iscompleted, and cannot be disposed as unsortedmunicipal waste.

The user is responsible for returning the product to theappropriate collection facility, as specified by the localcode.

For additional information regarding applicable locallaws, please contact the municipal facility and/or localdistributor.

Compressor Warranty Disclaimer

The refrigeration compressor(s) on this machine arewarranted for the term indicated on the warranty cardaccompanying this machine. However, due to theMontreal Protocol and the U.S. Clean Air ActAmendments of 1990, many new refrigerants arebeing tested and developed, thus seeking their wayinto the service industry. Some of these newrefrigerants are being advertised as drop--inreplacements for numerous applications. It should benoted that, in the event of ordinary service to thismachine’s refrigeration system, only the refrigerantspecified on the affixed data label should beused.The unauthorized use of alternate refrigerants will voidyour compressor warranty. It will be the owner’sresponsibility tomake this fact known to any technicianhe employs.

It should also be noted that Taylor does not warrant therefrigerant used in its equipment. For example, if therefrigerant is lost during the course of ordinary serviceto this machine, Taylor has no obligation to eithersupply or provide its replacement either at billable orunbillable terms. Taylor does have the obligation torecommend a suitable replacement if the originalrefrigerant is banned, obsoleted, or no longer availableduring the five year warranty of the compressor.

Taylor will continue to monitor the industry and testnew alternates as they are being developed. Should anew alternate prove, through our testing, that it wouldbe accepted as a drop--in replacement, then theabovedisclaimer would become null and void. To find out thecurrent status of an alternate refrigerant as it relates toyour compressor warranty, call the local TaylorDistributor or the Taylor Factory. Be prepared toprovide the Model/Serial Number of the unit inquestion.

Page 9: 0 h60 manual

5Model H60 Safety

110822

Section 3 Safety

We, at Taylor Company, are concerned about thesafety of the operatorwhen heor she comes in contactwith the freezer and its parts. Taylor has gone toextreme efforts to design and manufacture built--insafety features to protect both the operator and theservice technician. As an example, warning labelshave been attached to the freezer to further point outsafety precautions.

IMPORTANT -- Failure to adhere to thefollowing safety precautions may result in severepersonal injury or death. Failure to comply withthese warnings may damage the machine and itscomponents. Component damage will result inpart replacement expense and service repairexpense.

DONOT operate the freezer without readingthis Operator Manual. Failure to follow this instructionmay result in equipment damage, poor freezerperformance, health hazards, or personal injury.

Per IEC 60335--1 and its part 2 standards,“This appliance is to beusedonly by trainedpersonnel.It is not intended for use by children or people withreduced physical, sensory, or mental capabilities, orlack of experience and knowledge, unless givensupervision or instruction concerning the use of theappliance by a person responsible for their safety.”

This unit is provided with an equipotentialgrounding lug that is to be properly attached to the rearof the frameby the authorized installer. The installationlocation is marked by the equipotential bondingsymbol (5021 of IEC 60417-1) on both the removablepanel and the equipment’s frame.

DO NOT use a water jet to clean or rinse thefreezer. Failure to follow these instructions may resultin serious electrical shock.

S DO NOT allow untrained personnel tooperate this machine.

S DO NOT operate the freezer unless allservice panels and access doors arerestrained with screws.

S DO NOT remove any internal operatingparts (examples: freezer door, beater,scraper blades, etc.) unless all controlswitches are in the OFF position.

Failure to follow these instructionsmay result in severepersonal injury to fingers or hands from hazardousmoving parts.

This unit has many sharp edges that cancause severe injuries.

S DO NOT put objects or fingers in the doorspout. This may contaminate the productand cause severe personal injury from bladecontact.

S USE EXTREME CAUTION when removingthe beater asssembly. The scraper bladesare very sharp.

This freezer must be placed on a levelsurface. Failure to complymay result in personal injuryor equipment damage.

Cleaning and sanitizing schedules aregoverned by your state or local regulatory agenciesand must be followed accordingly. Please refer to thecleaning section of this manual for the properprocedure to clean this unit.

DO NOT draw product or attempt todisassemble the unit during the HEAT cycle. Theproduct is hot and under extreme pressure.

Page 10: 0 h60 manual

6 Model H60Safety

050831

DO NOT obstruct air intake and discharge openings:6” (152 mm) minimum air clearance on all sides and7--1/2” (191mm) minimum on bottom. Failure to followthis instruction may cause poor freezer performanceand damage to the machine.

For IndoorUseOnly: This unit is designed to operateindoors, under normal ambient temperatures of70_-75_F (21_-24_C). The freezer has successfullyperformed in high ambient temperatures of104_(40_C) at reduced capacities.

NOISE LEVEL: Airborne noise emission does notexceed 78 dB(A) when measured at a distance of 1.0meter from the surface of the machine and at a heightof 1.6 meters from the floor.

Page 11: 0 h60 manual

7Model H60 Operator Parts Identification

111114

Section 4 Operator Parts IdentificationH60

Page 12: 0 h60 manual

8 Model H60Operator Parts Identification

111114

H60 Exploded View Parts Identification

ITEM DESCRIPTION PART NO.

1 COVER--HOPPER COMPLETE 053809

2 AGITATOR A. X44797

3 PANEL A.--SIDE LEFT X48285

4 STUD--NOSE CONE 011390

5 PAN--DRIP 19--1/2 LONG 035034

6 SHIELD--SPLASH--WIRE 046177

7 TRAY--DRIP 14.8 046275

8 SCREW--1/4--20X3/8 RHM 011694

9 CASTER--SWV 5/8 STEM 018794

10 PANEL A.--SIDE RIGHT X48286

11 PANEL--SIDE UPPER 042317

12 O--RING--.643 OD X .077W 018572

ITEM DESCRIPTION PART NO.

13 TUBE A.--FEED--OUTER--HT X34641

14 O--RING--.291 ID X .080W 018550

15 TUBE A.--FEED--SC--INNER X32824--5

16 GASKET--SYRUP DOOR 045326

17 DOOR A.--SYRUP CABINET X45325

18 ADAPTOR A.--CASTER X18915

19 PANEL--REAR W/LOUVERS 026980--SP

20 LOUVER--SIDE 013631

21 PANEL A.--FRONT X46634

22 TRIM--REAR CORNER 046668

23 TRIM A.--SHELF X45334

24 CASTER--4” SWV 5/8 STEMW/BRAKE

034081

NOTE: PLEASE VERIFY PART NUMBERS FOR YOURSPECIFIC MACHINE WITH THE COMPLETE PARTSLIST AT THE END OF THE MANUAL.

Page 13: 0 h60 manual

9Model H60 Operator Parts Identification

H60 Door and Beater Assemblies

ITEM DESCRIPTION PART NO.

1 SEAL--DRIVE SHAFT 032560

2 SHAFT--BEATER 035527

3 BEATER A.--7QT--1 PIN X46233

4 BEARING--FRONT 013116

5 GASKET--DOOR 5.177ID 016672

6 BEARING--GUIDE 014496

7 TORQUE A. X17381

8 ARM--TORQUE 014500

9 O--RING--.291 ID X .080W 018550

10 BEARING--SPINNER 017032

11 VALVE A.--DRAW X54821

ITEM DESCRIPTION PART NO.

12 O--RING--1--1/16 OD X .139W 013029

13 NUT--STUD *GENERAL USAGE* 021508

14 TUBE--VINYL 3/16 X 1/16 WAL 020940--

15 FITTING--QD MALE INSERT 036296

16 O--RING--5/16 OD X .070 W 016272

17 DOOR A.--1 SPOUT--METAL X17373

18 HOUSING--SPINNER *4 SPIGOT 017269

19 BLADE A.--SPINNER *8 3/8 X35570

20 BLADE--SCRAPER--PLASTIC 046237

21 CLIP--SCRAPER BLADE*8.75” 046238

Page 14: 0 h60 manual

10 Model H60Operator Parts Identification

H60 Syrup Tank -- 045533

ITEM DESCRIPTION PART NO.

1 TANK--SYRUP--4 QT. 045533

1a COVER--TANK W/ FTG 035759--1

1b TIP--NYLON--WHITE TRANSL. 042747*

1c O--RING--3.437 ID X .275 W 016037

1d TUBE--DIP--4 QT. 015441--7

1d--1 O--RING--.291 ID X .080W 018550

2 PLUG--Q.D. CO2 1/8 MP 021077

3 SOCKET--Q.D. CO2 90DEG 1/4 021524

4 SOCKET--Q.D. LIQ.--90DEG--1/4 021026

ITEM DESCRIPTION PART NO.

4a** RESTRICTOR--SYRUP 030917

4b** GASKET--RUBBER 023551

5 O--RING--5/8 OD X .103W 016030

6 PLUG--Q.D. LIQ. 3/4--18 FP 021081

6a VALVE A.--QD PLUG 021081--2

6b INSERT 021081--1

7 DECAL--SET 4 SYRUP FLAVOR 021523

8 DECAL--SYRUP TANK INST. 045533--1

* TIP--NYLON--GREY 024261(DUAL SUPPLIER, ORDER AS NEEDED)

** NOTE: NOT USED ON CHOCOLATE.

Page 15: 0 h60 manual

11Model H60 Operator Parts Identification

Accessories

ITEM DESCRIPTION PART NO.

1 BRUSH-MIX PUMP BODY -3” X 7” WHITE

023316

2 BRUSH-END-DOOR-SPOUT 0397193 KIT A.-TUNE UP X346154 BRUSH-DOUBLE ENDED 0130725 BRUSH-REAR BRG 1IN.D X 2IN 013071

ITEM DESCRIPTION PART NO.

6 BRUSH-DRAW VALVE 0147537 LUBRICANT-TAYLOR HI PERF 0482328 PAIL-MIX 10 QT. 013163* SANITIZER·KAY-5·200·PKTS 041082

* SANITIZER-STERA SHEEN-GR100 (2 OZ.) PKTS

055492

*NOT SHOWN

Page 16: 0 h60 manual

12 Model H60Important: To the Operator

Section 5 Important: To the Operator

Item Description

1 Power Switch (Toggle)2 Liquid Crystal Display3 LCD Indicator -- MIX LOW (PCB A.--LED)4 LCD Indicator -- MIX OUT (PCB A.--LED)5 Consistency Control (Switch--Torque)6 Flavor Selector Keypad (Switch--Membrane)7 Rinse Key (Switch--Membrane)

Symbol Definitions

To better communicate in the International arena, thewords on many of our operator switches and buttonshave symbols to indicate their functions. Your Taylorequipment is designed with these Internationalsymbols.

The following chart identifies the symbol definitionsused on the operator switches.

= ON

= OFF

= MIX LOW

= MIX OUT

= HEAT MODE

= CLEAN MANUALLY

= CALIBRATE

= WASH

= AUTO

= MENU

= CHOCOLATE

= STRAWBERRY

= VANILLA

= OPTIONAL

= RINSE

Page 17: 0 h60 manual

13Model H60 Important: To the Operator

Power Switch

When placed in the ON position, the power switchallows control panel operation. The power switch islocated on the left side of the control channel.

Liquid Crystal Display

TheLiquidCrystalDisplay (LCD) is locatedon the frontcontrol panel. The LCD is used to show the currentmode of operation, and whether or not there issufficient mix.

LCD Indicator -- MIX LOW

The “MIX LOW” indicator flashes to indicate that thereis a low supply of mix. The mix hopper should be filledas soon as possible.

LCD Indicator -- MIX OUT

The MIX OUT light will illuminate, indicating that themix hopper has an insufficient supply of mix to operatethe freezer. The MIX OUT indicator will flash. At thistime, the freezer will go into the STANDBY mode ofoperation. To return the freezer to the AUTO mode, fillthe hopper with mix and press the AUTO key. Thefreezer will automatically begin operation.

Consistency Control

The viscosity (thickness) of the shake is controlled bya sensing device called the consistency control. Theconsistency control knob is located to the lower rightof the control channel. To achieve a thicker shake, turnthe knob clockwise and counterclockwise to achieve athinner shake consistency.

Allow the refrigeration system to cycle on and off 2 or3 times before an accurate consistency can beevaluated.

Flavor Selector Keypad

Four shake flavors are offered from the Model H60freezer: chocolate, strawberry, vanilla (unflavoredproduct), and an optional flavor. Press the desiredshake flavor key and open the drawvalve. Product andsyrup will automatically blend to produce the chosenflavor.

RINSE

After the shake is drawn, press theRINSEkey to rinseexcess syrup and mix from the spinner housing.

Reset Mechanism

The reset button is located under the right side panel.The reset mechanism protects the beater motor froman overload condition. If an overload occurs, the resetmechanism will trip. To properly reset the freezer,press the reset button firmly and clear the tone perinstructions in “Clearing Fault Tones” on page 17.

If the reset mechanism trips again, contact yourauthorized Taylor Distributor to resolve the problem.

Warning: Do not use metal objects topress the reset button. Failure to comply mayresult in severe personal injury or death.

Page 18: 0 h60 manual

14 Model H60Important: To the Operator

Operating Screen Descriptions

When themachine is powered the systemwill initialize.The screen will display “INITIALIZING”. There will befour types of data the system will check: LANGUAGE,SYSTEM DATA, CONFIG DATA, and LOCKOUTDATA. During the INITIALIZING... LANGUAGEscreen, the alarm will be on. If the system data,configuration data, or lockout history data has becomecorrupt, the following screenwill alert the operator thatthe system settings may have been changed.

NVRAM FAULTRESET TO DEFAULTSPRESS SEL KEY

Once the system has initialized the SAFETYTIMEOUT screen is displayed and the alarm is turnedon.

SAFETY TIMEOUTANY KEY ABORTS

This screen will be displayed, with the alarm on, for 60seconds or until any key is pressed.

After the safety timeout has been completed, and thepower switch is OFF, one of the following screens isdisplayed.

The first screen is displayed if the machine is not in abrush clean state.

POWER SWITCH OFFMIX: OUT TIME: 4:30HOPPER: 62.1BARREL: 67.7

If any of the requirements for a brush clean have notbeen met, the time displayed will remain at 5:00minutes. When all the requirements for a brushcleaning are met, and the five minutes expire, thescreen will change to the second screen, which is thestandard power switch OFF screen.

POWER SWITCH OFF-- = -- = -- = -- = -- = --UNIT CLEANED

When the power switch is set in the ON position, thesystem mode of operation screen is displayed. In thisexample, themachine is ON, but nomode of operationhas been selected. The second line of the displayindicates whether there is a sufficient supply of mix inthe hopper or if there is a LOW or OUT mix condition.The third line of the display shows the temperature ofthe mix hopper. After pressing the AUTO key, the lastline of the display shows the month and date (MM =month, DD = day) that the machine needs to bedisassembled and brush cleaned.

MODE: OFFMIX: OKHOPPER: 40.0FBRUSH CLEAN ON: MM/DD

The next display indicates the freezer is operating intwo different modes. The following information isgiven:

The machine is operating in the WASH and PUMPmodes and the mix level in the hopper is low. Thetemperature of themix hopper is 40_F (4.4_C), and themachine needs to be brush cleaned on October 31st.

MODE: WSH--PMPMIX: LOWHOPPER TEMP: 40.0 FBRUSH CLEAN ON: 10/31

Page 19: 0 h60 manual

15Model H60 Important: To the Operator

070316

The following displays pertain to the HEAT cycle:

Effective 12/8/06, a SystemAlert screenwas added todisplay an alert and alarm 15minutes prior to the startof the heat cycle. The system alert functions similar tothe Fault Description except there is no menu item.The alarm will sound and show on the display. Thealarm will sound until the SEL key is pressed to clearthe fault. This feature allows the operator time tomakesure the freezer is in AUTO or STANDBY, and has theproper amount of mix in the hopper before the start ofthe heat cycle.

SYSTEM ALERTHEAT TREAT CYCLE

SEL

While in the heating phase, you will see this display. Itshows the present temperature of the hopper.

MODE: HEATPHASE: HEATHOPPER: 140.0 FBRUSH CLEAN ON: MM/DD

The mix temperature must be raised above 151_F(66.1_C) within 90minutes or the freezerwill be lockedin STANDBY, and the cycle failure display will appear.

In the example, the hopper temperature is 140_F(60_C). The phase shows that the machine is in theheat phase of the heat treatment cycle.

When the heating phase is complete, the freezer goesinto the holding phase of the cycle. The holding phasewill hold the temperature above 151_F (66.1_C) for aminimum of 30 minutes.

In this example, the hopper temperature is 151_F(66.1_C).

MODE: HEATPHASE: HOLDHOPPER: 151.0 FBRUSH CLEAN ON: MM/DD

The final phase of the heat treatment cycle is thecooling phase. Now the freezer must cool the mixbelow 41_F (5_C). If the product fails to cool in twohours, the freezer will lock out.

This example illustrates that the temperature is beinglowered, but has not yet reached the set point.

MODE: HEATPHASE: COOLHOPPER TEMP: 55.0 FBRUSH CLEAN ON: MM/DD

The entire heat treatment cycle must be completed infour hours.

When the entire heat cycle has been completed, thenormal display will appear, showing themachine in theSTANDBY mode. The machine may now be placed inthe AUTO mode or left in the STANDBY mode.

MODE: STANDBYMIX: OKHOPPER: 41.0 FBRUSH CLEAN ON: MM/DD

Hard Lock: There are two causes for a hard lock:

1. Fourteen days have elapsed since the lastbrush cleaning. The following screen will bedisplayed.

14 DAY TIMEOUTCLEANING REQ’DFREEZER LOCKEDPRESS SEL KEY

2. There has been a thermistor failure (freezingcylinder, hopper, or glycol) during the heattreatment process.

SYSTEM FAULTSERVICE REQ’D

FREEZER LOCKEDPRESS SEL KEY

All four LED’s on the front of the freezerwill light. Pressthe MENU/SEL key.

The next display is the screen which will appear afterthe failuremessage. To complywith health codes, heattreatment system freezers must complete a heattreatment cycle daily, andmust also be brush cleanedevery 14 days. Brush cleaning is the normaldisassembly and cleaning procedures. Failure to

Page 20: 0 h60 manual

16 Model H60Important: To the Operator

follow theseguidelineswill cause the control to lock thefreezer out of the AUTO mode. Press the WASH key.

NO AUTO OPERATIONALLOWED UNTILBRUSH CLEANINGPRESS WASH KEY

The next display is the screen which will appear afterthe brush cleaning message and illustrates that thecontrol is in the OFF mode and the machine needs tobe disassembled and brush cleaned.

MODE: OFFMIX: OKHOPPER TEMP: 41.0 FFREEZER LOCKED

Once the unit is unlocked, only the MIX OUT and MIXLOW LED’s will light.

Soft Lock: If a heat treatment cycle has not beeninitiated within the last 24 hours, all four LED’s on thefront of the machine will light and a message willappear on the LCD. Line 3 of the LCD will indicate thereason the message appears.

NO HEAT TREAT STARTBECAUSE

VARIABLE MESSAGEPRESS SEL KEY

Following are the variablemessages whichwill appearon line 3:

1. POWER SWITCH OFF: Power switch was inthe OFF position.

2. MIX OUT PRESENT: There was mix outcondition present.

3. AUTO OR STANDBY OFF: The unit was not inthe AUTO or STANDBY mode.

4. NO HEAT CYCLE TRIED: A heat treatmentcycle was not attempted in the last 24 hours.(AUTO HEAT TIME was advanced, or a powerloss was experienced at the time the cycle wasto occur, or a heat cycle failure not due to athermistor failure.)

If the following screen appears, a soft lock hasoccurred during the heat treatment cycle.

HEAT TREAT CYCLEFAILURE

FREEZER LOCKEDPRESS SEL KEY

If the temperature of the product has not fallen below41_F (5_C) by theendof theCOOLcycle, the followingscreen will appear.

PRODUCT OVER TEMPFREEZER LOCKEDPRESS SEL KEY

Press the MENU/SEL key to advance to the nextdisplay.

When one of these messages appears, automaticfreezer operation cannot take place until the freezer isdisassembled and brush cleaned or has completed aheat treatment cycle.

Thenext displaywill instruct theoperator to start aheattreatment cyclemanually (by pressing the AUTO key),or to disassemble and brush clean the freezer. If theAUTO key is pressed, the freezer will automaticallystart the heat treatment cycle and only the heat cycleLED will light.

NO AUTO OPERATIONALLOWED. PRESS

AUTO FOR HEAT CYCLEWASH TO BRUSH CLEAN

If the WASH key is pressed, the next display willappear and the freezer will have to be disassembledand brush cleaned.

MODE: OFFMIX: OKHOPPER TEMP: 41.0FFREEZER LOCKED

Once the freezer is unlocked by starting a heattreatment cycle, only theheat cycle LEDwill light. If thefreezer is unlocked by brush cleaning, the mix low andmix out LED’s will light.

Page 21: 0 h60 manual

17Model H60 Important: To the Operator

060807

Operator Menu

The OPERATOR MENU is used to enter the operatorfunction displays. To access the OPERATOR MENU,simply press the MENU/SEL key. The cursor will flashover the letter “A” indicating that this is screen “A”. Toselect a different screen, use the arrowkeys andmovethe cursor to the desired screen selection and pressthe MENU/SEL key.

OPERATOR MENUA B C D E F G H I J K

EXIT FROM MENU<-- -- -- -- -- --> SEL

Screen “B” is FAULT DESCRIPTION. The faultdescription will indicate if there is a fault with thefreezer and the side of the freezer where the faultoccurred.

FAULT DESCRIPTIONVARIABLE MESSAGE

CLR SEL

Clearing Fault Tones

To clear the tone for any faults which have beencorrected, press the CALIBRATE key. To see if thereis more than one fault per cylinder, press theMENU/SEL key. When the last fault is displayed, thecontrol will return to the OPERATORMENU. To returnto the main screen, move the cursor to “A” and pressthe MENU/SEL key again.

Listed below are the variable messages which willappear, along with the corrective action:

1. NO FAULT FOUND: There was no fault foundin the freezer. Nothing will appear on the screenafter this variable message appears.

2. BEATER OVERLOAD: Press the reset buttonfirmly. Clear the tone per instructions in“Clearing Fault Tones” on page 17.

3. CHK REFRIG SYS PSI: Place the powerswitch in the OFF position. Wait 5 minutes forthe machine to cool. Place the power switch inthe ON position. Clear the tone per instructionsin “Clearing Fault Tones” on page 17.

4. COMP ON TOO LONG: Place the powerswitch in the OFF position. Call servicetechnician. Clear the tone per instructions in“Clearing Fault Tones” on page 17.

5. HOPPER THERM BAD: Place the powerswitch in the OFF position. Call servicetechnician.

6. BARREL THERM BAD: Place the powerswitch in the OFF position. Call servicetechnician.

7. GLYCOL THERM BAD: Place the powerswitch in the OFF position. Call servicetechnician.

8. HOPPER OVER TEMP: The hoppertemperature has risen too high as follows. Clearthe tone per instructions in “Clearing FaultTones” on page 17.

a. The hopper temperature reaches 41_F.(5_C.) or higher after a power failure.

b. The hopper temperature has not fallen below41_F. (5_C.) by the end of the COOL phasein the heat cycle.

9. BARREL OVER TEMP: The barrel temperaturehas risen too high as follows. Clear the tone perinstructions in “Clearing Fault Tones” onpage 17.

a. Thebarrel temperature reaches 41_F. (5_C.)or higher after a power failure.

b. The barrel temperature has not fallen below41_F. (5_C.) by the end of the COOL phasein the heat cycle.

10. POWER FAILURE: This message will appearin the FAULT DESCRIPTION if a power failurehas occurred. Clear the tone per instructions in“Clearing Fault Tones” on page 17.

Page 22: 0 h60 manual

18 Model H60Important: To the Operator

081111

Screen “C” is SETCLOCK. This screenwill display thecurrent date and time. The date and time may only bechanged after the freezer has been manually brushcleaned but before it has been placed in the AUTOmode. Move the cursor under the number you wish tochange. Press the plus key to increase the number;press the minus key to decrease the number. Whenthe desired time and date appears, press theMENU/SEL key once to return to the OPERATORMENU.

SET CLOCK10:21 AM 11/07/2001-- --<-- -- -- -- -- --> +++ -- -- -- SEL

If an illegal date is entered, the following screen willappear. The correct date must be entered beforeleaving this display.

SET CLOCK10:34 AM 02/30/2001-- -- INVALID DATE<-- -- -- -- -- --> +++ -- -- -- SEL

Screen “D” is SET RINSE TIME. This screen is usedto set the amount of time needed to rinse the spinnerhousing of syrup after a shake has been drawn. Pressthe plus key to increase the number; press the minuskey to decrease the number. When the desired timeappears, press the MENU/SEL key once to return tothe OPERATOR MENU.

SET RINSE TIMETIME: 3.0 SEC

+ + + -- -- -- SEL

Screen “E” is SYSTEM INFORMATION. The firstscreen will indicate the software version used in theunit.

SOFTWARE VERSIONH60 Control UVC2Version 2.03

SEL

Press the MENU/SEL key to view the second screenof the SYSTEM INFORMATION display. This screenwill indicate the version number and number oflanguage strings.

LanguageV1.10r00 English 457

SEL

Press the MENU/SEL key to view the third screen ofthe SYSTEM INFORMATION display. This screenwillindicate the Bill of Material number and serial numberfor the unit. Press the MENU/SEL key once to returnto the Operator Menu.

B.O.M. 0H6027E710S/N K0000000

SEL

Screen “F” is AUTO HEAT TIME. This screen is usedto set the time of day in which the heat treatment cyclewill start. Move the cursor under the number you wishto change. Press the plus key to increase the number;press the minus key to decrease the number. Whenthe desired time appears, press the MENU/SEL keyonce to return to the OPERATOR MENU.

AUTO HEAT TIMETIME: 12:00 AM

-- --<-- -- -- -- -- --> +++ -- -- -- SEL

Screen “G” is CURRENT CONDITIONS. This screengives the viscosity of the product and the hopper andbarrel temperatures. The last line of the display is thecompressor countdown safety timer. The safety timerprevents the compressor from running more than 11minutes (other than during the cooling phase of theheat treatment cycle).

Press the MENU/SEL key once to view theSERVINGS COUNTER screen.

VISC HOPPER BARREL0 38.5 28.5

TIME C 11:00 11:00

Page 23: 0 h60 manual

19Model H60 Important: To the Operator

The SERVINGS COUNTER screen indicates thenumber of times the draw switch has closed (numberof draws) since the last brush cleaning or since the lastserving counter reset. A maximum of 32,767 drawscan be recorded; an additional draw will cause thecounter to restart at zero. Pressing theMENU/SELkeywill return the display to the Operator Menu.

SERVINGS COUNTERDRAWS12

SEL

Draws are counted during the AUTO mode ofoperation only.

Screen “H” is HEAT CYCLE DATA. The informationfrom the previous heat treatment cycles can beobtained through this screen. The most recent heattreatment cycle data will be shown first; press the pluskey to scroll through the remainingheat cycle displays.If a heat treatment cycle failure should occur, a twocharacter message will appear on the second line ofthe screen. Press the MENU/SEL key once to returnto the OPERATOR MENU.

00:00 00:00 00:00HEAT OVER COOL RC00:00 00:00 00:00TEMP AT END 0.0 1

Listed below are the variable messages which couldappear:

HT Failure in the heating phase.CL Failure in the cooling phase.TT Failure in meeting total heat treatment cycle

time requirement.MO Mix out condition.OP Operator interruption.PF Power failure. (If a power failure occurs, but

the heat treatment cycle does not fail, anasterisk (*) will appear on the 3rd line of thedisplay.)

BO Beater overload.HO High pressure cut--out.TH Failed thermistor probe.PS Power switch placed in the OFF position.ML Mix Low Condition.14 14 Day Timeout Occurred.RC Heat Cycle Record Cleared.

Pressing the CALIBRATE key on any HEAT CYCLEDATA screen will cause the extended data screen tobe displayed. This screen shows the hopper, barrel,and glycol temperatures, and the amount of time thefreezer spent in the phase of the heat cycle when theheat cycle completed, or was terminated.

HOPPER BARREL GLYCOL151.0 134.5 178.0

PHASE TIME: 1:20 1

Screen “I” is the LOCKOUT HISTORY. This screendisplays a history of the last 40 hard locks, soft locks,and brush clean dates. Page numbers are indicated inthe upper right hand corner. Page 1 always containsthe most recent failure. Press the PUMP/+++ key tocycle through the pages.

The second line of the screen displays the date andtime a failure occurs. The third line indicates thereason for a failure, or will indicate a successful brushcleaning has occurred. Some failures occur formultiple reasons. When this occurs, a page will begenerated for each reason. Press the MENU/SEL keyonce to return to the Operator Menu.

LOCKOUT HISTORY 111/21/01 02:08SOFTLOCK ABORT

+++ -- -- -- SEL

Screen “J” is the SERVICE MENU. This screen canonly be accessed by a service technician.

Screen “K” is the STANDBY MODE. To place thefreezer in the STANDBYmode, move the cursor underthe word “yes”. Press the MENU/SEL key to executethe command. Pressing the MENU/SEL key again willreturn you to the main screen. To exit the STANDBYmode and place the unit inAUTO, press the AUTOkeyonce. Pressing the AUTO key again will place the unitin the OFF mode.

STANDBY MODESTANDBY YES NO

-- -- --<-- -- -- -- -- --> SEL

Page 24: 0 h60 manual

20 Model H60Operating Procedures

Section 6 Operating Procedures

The Model H60 has one 7 quart (6.6 liter) freezingcylinder. This automatic freezer offers four separateflavors which are blended and ejected from one spout.(Use only single strength syrup that is free of pulp andseeds.)

We begin our instructions at the point where we enterthe store in the morning and find the partsdisassembled and laid out to air dry from the previousnight’s brush cleaning.

These opening procedures will show you how toassemble these parts into the freezer, sanitize them,and prime the freezer with fresh mix in preparation toserve your first shake.

If you are disassembling the machine for the first timeor need information to get to this starting point in ourinstructions, turn to page 32, “Disassembly”, and startthere.

Assembly

Note: When lubricating parts, use an approved foodgrade lubricant (example: Taylor Lube HP).

MAKE SURE THE POWER SWITCH IS INTHE OFF POSITION!. Failure to do so may causeinjury from hazardous moving parts, or electrocution.

Be certain your hands are sanitized beforeassembling the freezer.

Step 1Lubricate the groove and shaft portion of the beaterdrive shaft. Slide the seal over the shaft and grooveuntil it snaps into place. DONOT lubricate the hex endof the drive shaft. Fill the inside portion of the seal with1/4” more lubricant. Lubricate the flat side of the sealthat comes in contact with the bearing.

Figure 1

Note: Make sure the seal is not installed inside--out.The ridge that protrudes in the center of the seal shouldbe on the outside.

Install the drive shaft. Insert the drive shaft into thefreezing cylinder, hex end first, and into the rear shellbearing until the seal fits securely over the rear shellbearing. Be certain the drive shaft fits into the drivecoupling without binding.

Figure 2

Page 25: 0 h60 manual

21Model H60 Operating Procedures

Step 2Install the beater assembly. First check scraper bladesfor any nicks or signs of wear. If any nicks are present,replace both blades.

If blades are in good condition, install the scraper bladeclips on the scraper blades. Place the rear scraperblade over the rear holding pin on the beater.

Figure 3

Note: The hole on the scraper blade must fit securelyover the pin to prevent costly damage.

Hold the rear blade on the beater and slide it halfwayinto the freezing cylinder. Install the front scraper bladeover the front holding pin. Slide the beater assemblycompletely into the freezing cylinder.

Figure 4

Make sure the beater assembly is in position over thedrive shaft. Turn the beater slightly to be certain thatthe beater is properly seated. When in position, thebeater will not protrude beyond the front of the freezingcylinder.

Figure 5

Step 3Install the torque rotor assembly. Assemble the torquerotor by sliding the two o--rings on the front of the shaftand lubricate them thoroughly to prevent leaking.Place the white plastic guide bearing on the rear of therotor shaft. DO NOT lubricate plastic guide bearing.

Figure 6

Insert the torque rotor, plastic guide bearing end first,making sure that it fits into the hole in the beater driveshaft. Rotate it several times to check for properpositioning.

Figure 7

Page 26: 0 h60 manual

22 Model H60Operating Procedures

Step 4Install the draw valve. Lubricate the plastic spinnerbearing. Insert the plastic spinner bearing into the topof the draw valve.

Figure 8

Slide the two o--rings onto the draw valve andlubricate.

Figure 9

Lubricate the inside of the door spout, top and bottom,and insert the draw valve into the freezer door from thetop. It will be necessary to rotate the draw valve to theright when assembling the door to the freezer.

Figure 10

Step 5Assemble the freezer door. Place the large rubbergasket into the groove on the back side of the freezerdoor. DO NOT lubricate the gasket.

Slide the white plastic front bearing onto the bearinghub, making certain that the flanged end of thebearingis resting against the freezer door. DO NOT lubricatethe front bearing.

Figure 11

Page 27: 0 h60 manual

23Model H60 Operating Procedures

Install the freezer door. Locate the torque rotor in thecenter hole of the freezer door. Position thedoor on thefour studs on the front of the freezing cylinder andfirmly push it into place. Install the four handscrews onthe studs and finger--tighten equally in a criss--crosspattern to insure the door is snug. Do notover--tighten.

Figure 12

Step 6Install the rear drip pan. Slide the drip pan into the holein the front panel.

Figure 13

Step 7Snap theplastic spinner housingonto thebottomof thedoor spout.

Figure 14

Install the spinner blade. Lubricate the shaft of thespinner blade. Insert the spinner blade from thebottominto the center of the draw valve until the shaft appearsat the top of the draw valve.

Figure 15

Page 28: 0 h60 manual

24 Model H60Operating Procedures

Locate the spinner coupling and slip it over the slottedend of the spinner blade shaft. Raise the slip collar onthe coupling and turn the shaft until the spinnercoupling slips down into its locking position.

Figure 16

Step 8Rotate the draw valve to the left, and center it inposition on the draw arm. Place the valve in the slottedgroove of the draw valve bracket.

Figure 17

Step 9Install the torque arm. Position the torque arm byslipping it up through the slot in the operating arm, andthen down into the hole in the torque rotor shaft. Checkthe torque arm by moving it back and forth to be sureit moves freely and easily.

Step 10Connect the syrup lines. Connect the syrup lines of thespinner housing to the quick disconnect fittings on thefront panel.

Figure 18

Step 11Install the front drip tray and splash shield.

Figure 19

Step 12Slide the three o--rings into the grooves of the inner airtube.

Figure 20

Page 29: 0 h60 manual

25Model H60 Operating Procedures

080627

Slide the two o--rings into the grooves of the outer airtube.

Figure 21

Step 13Lay the inner air tube, outer air tube, and agitator in thebottom of the mix hopper for sanitizing.

Figure 22

Sanitizing

Step 1Prepare an approved 100 PPM sanitizing solution(examples: 2--1/2 gal. [9.5 liters] of Kay--5R or 2gal. [7.6 liters] of Stera--SheenR). USE WARMWATER AND FOLLOW THE MANUFACTURER’SSPECIFICATIONS.

Step 2Pour the sanitizing solution over all the parts in thebottom of the mix hopper and allow it to flow into thefreezing cylinder.

Note: You have just sanitized themix hopper andparts; therefore, be sure your hands are sanitizedbefore going on in these instructions.

Step 3While the solution is flowing into the freezing cylinder,take particular care to brush clean the mix levelsensing probes, the mix hopper, mix inlet hole, innerand outer air tubes, the outside of the agitator housing,and the agitator. Brush the exposed sides of thehopper.

Step 4Place the power switch in the ON position.

Step 5Press the WASH key and allow the sanitizing solutionin the freezing cylinder to agitate for five minutes.

Figure 23

Page 30: 0 h60 manual

26 Model H60Operating Procedures

Step 6With a pail beneath the dispensing spout, open andclose the draw valve six times. Draw off the remainingsanitizing solution.

Figure 24

Step 7Once the sanitizer stops flowing from the dispensingspout, close the draw valve and press the WASH key,cancelling the beater motor operation.

Note: Be sure your hands are clean and sanitizedbefore continuing these instructions.

Step 8Lubricate the o--rings on the inner and outer air tubes.Place the inner air tube inside theouter air tube and layin bottom of mix hopper.

Figure 25

Step 9Stand the assembled air tubes in the corner of the mixhopper and place the agitator on the agitator housing.

Figure 26

Note: If the agitator stops turning during normaloperation, remove the agitator from the agitatorhousing and brush clean these parts with sanitizingsolution. Install the agitator back onto the agitatorhousing. Be sure your hands are sanitized whenperforming this step.

Priming

Step 1Place a mix pail beneath the dispensing spout, andopen the draw valve. Pour two gallons (7.6 liters) ofFRESHmix into themix hopper and allow it to flow intothe freezing cylinder. This will force out any remainingsanitizing solution.

Figure 27

Page 31: 0 h60 manual

27Model H60 Operating Procedures

When full strength mix is flowing from the dispensingspout, close the draw valve.

Figure 28

Step 2When mix stops bubbling down into the freezingcylinder, install the assembled air tubes in the mix inlethole.

The pin on the inner air tube should be turned andpositioned at the bottom of the notch in the outer airtube. This will align the holes in the air tubes and allowmix and air to enter the freezing cylinder.

Figure 29

Step 3Press the AUTO key. When the unit cycles off, theproduct will be ready to serve.

Figure 30

Step 4Fill the hopper with fresh mix and place the mix hoppercover in position.

Note: Use only FRESHmix whenpriming the freezer.

Daily Closing Procedures

THIS PROCEDUREMUST BE PERFORMEDONCEDAILY!

The function of the Heat Treatment Cycle is to destroybacteria by raising the temperature of the mix in thefreezing cylinder and the hopper to a specifiedtemperature for a specified period of time, and thenbringing the temperature back down low enough toretard spoilage.

The Heat Treatment Cycle will start at the timedesignated in the Auto Heat Time.

Important: The level of mix in the mix hopper must beat the line on the agitator paddle. (The mix low lightmust not be ON.)

Note: If the CLEAN MANUALLY light is flashing, themachine must be disassembled and brush cleanedwithin 24 hours.

The freezer must first be in the STANDBY or AUTOmode before the HEAT cycle may be started.

MAKE SURE YOUR HANDS ARE SANITIZEDBEFORE PERFORMING THESE NEXT STEPS.

Page 32: 0 h60 manual

28 Model H60Operating Procedures

010917

Step 1Remove the hopper cover, assembled air tube, andagitator. Take these parts to the sink for furthercleaning and sanitizing.

Note: Pressing the left arrow key will stop the agitatorrotation for ten seconds.

Figure 31

Step 2Remove the spinner blade from spinner housing.Remove the spinner bearing from the draw valve andthe spinner housing from the freezer door spout.Disconnect syrup lines from fittings on front panel.Take these parts to the sink for further cleaning andsanitizing.

Step 3Remove the rear drip pan, front drip tray, and splashshield and take to the sink for further cleaning.

Rinse these parts in cool, clean water. Prepare a smallamount of an approved cleaning solution and brushclean parts.

Step 4Place the spinner housing, spinner blade, spinnerbearing, front drip tray, and splash shield on a clean,dry surface to air--dry overnight or until the heatingcycle is complete.

Step 5Prepare a small amount of an approved 100 PPM san-itizing solution. USE WARM WATER AND FOLLOWTHE MANUFACTURER’S SPECIFICATIONS. Sanit-ize the air tube assembly, agitator, hopper cover, andrear drip pan.

Important: Install the agitator back onto theagitator housing.

Note: Press the <-- -- key to stop the agitator motionfor 10 seconds.

Step 6Install the air tube assembly. Lift and turn the inner airtube of the assembled air tubes so the pin rests on topof the outer air tube. This will close the hole in theassembled air tubes, preventing mix in the hopperfrom entering the freezing cylinder during the heatingand standby process.

Figure 32

Replace the hopper cover and install the rear drip pan.

Step 7Return to the freezer with a small amount of cleaningsolution. Dip the end brush into the cleaning solutionand brush clean the door spout and bottom of the drawvalve.

Note: To assure sanitary conditions are maintained,brush each item for a total of 60 seconds, repeatedlydipping the brush in cleaning solution.

Rinse a single service towel in cleaning solution andwipe down the freezer door and area around thebottom of the freezer door.

Note: Once the heating cycle has started it cannot beinterrupted. The heating cycle will take a maximum of3 hours to complete.

DO NOT draw product or attempt todisassemble the unit during the HEAT cycle. Theproduct is hot and under extreme pressure.

Page 33: 0 h60 manual

29Model H60 Operating Procedures

080627

When the heating cycle is complete, the control willreturn to the STANDBY mode.

There are three phases of the heat cycle; Heating,Holding and Cooling. Each phase has a time limit. Ifany 1 of the 3 phases fails to reach the propertemperatures within the time limit, the cycle willautomatically abort and return to the STANDBYmode.The LCD will display the message “HEAT TREATCYCLE FAILURE -- FREEZER LOCKED -- PRESSSEL KEY”. The product may not be safe to serve. Thefreezer will be locked out of the AUTO mode. Discardproduct and brush clean machine.

Daily Opening Procedures

Evaluate the condition of LED’s (lights) and screenmessages (Hard Lock or Soft Lock, etc.) beforeperforming opening procedures. As indicated in theillustration below, 4 flashing LED’s, indicate a “locked”condition.

Figure 33

MAKE SURE YOUR HANDS ARE CLEANAND SANITIZED BEFORE PERFORMING THESENEXT STEPS.

Step 1When the heating cycle is complete, the normal dis-play will appear, showing the machine in theSTANDBY mode. Prepare a small amount of an ap-proved 100 PPM sanitizing solution (examples:Kay--5R or Stera--SheenR). USE WARM WATERAND FOLLOW THE MANUFACTURER’SSPECIFICATIONS.

Sanitize the spinner housing and lines, spinner blade,spinner bearing, front drip tray, and splash shield in thissolution.

Step 2Return to the freezer with a small amount of sanitizingsolution. Dip the end brush into the sanitizing solutionand brush clean the door spout and bottom of the drawvalve.

Note: To assure sanitary conditions are maintained,brush clean each item for a total of 60 seconds,repeatedly dipping the brush in sanitizing solution.

Rinse a single service towel in sanitizing solution andwipe down the freezer door and area around thebottom of the freezer door.

Replace the front drip tray and splash shield.

Step 3Replace the spinner housing. Connect syrup lines tothe quick disconnect fittings on the front panel.

Lubricate the spinner blade shaft and spinner bearingand replace these parts in the unit.

MAKE SURE YOUR HANDS ARE SANITIZEDBEFORE PERFORMING THIS NEXT STEP!

Step 4Lift hopper cover and turn the inner air tube of theassembled air tubes so the pin rests at the bottom ofthe notch of the outer air tube.

Figure 34

Step 5Press the AUTO key to resume normal operation.When the unit cycles off, product is ready to serve.

Page 34: 0 h60 manual

30 Model H60Operating Procedures

Syrup System

Twomain objectives in your opening procedures mustbe to: (1) fill the syrup tanks, and (2) calibrate the syrupflow. This must be checked daily to insure the highquality shake you desire.

Discard syrup weekly and flush syrup lines at leastonce a week. This will prevent syrup clogging the linesand will break the bacteria chain. See page 33 tosanitize the syrup system.

Note: Strawberry syrup lines use restrictors at thesyrup tank quick disconnect connection to maintainproper calibration. If thin viscosity syrups are used, itwill be necessary to install a restrictor in the syrup lineconnection.

To install the restrictors, unscrew the quick disconnectfrom the elbow portion of the syrup line. Make sure theo--ring rests on the end of the quick disconnect fitting.Place the restrictor on top of the o--ring and screw thequick disconnect back onto the syrup line.

The syrup tanks are located in the lower front syrupcompartment. The air lines and syrup lines are colorspiral wrapped. Be sure tomatch the color wrappedairand syrup line to the correct syrup flavor.

Step 1Filling the syrup tanks: Pull back on the collar of thequick disconnect fitting for the air lines. Allow the airpressure to dissipate from the syrup tanks. Disconnectthe syrup lines.

CAUTION: Make sure you disengage the air linebefore you disengage the syrup line.

Remove the syrup tank from the compartment.Remove the syrup tank lid by lifting up on the lockinglever. Fill the syrup tank with syrup to the indicatingmark on the label. IMPORTANT: Do not overfill thetanks.

Replace the tank lid, match and connect the spiralwrapped syrup line to the syrup tank. Connect the airline to the syrup tank.

Repeat this step for all syrup tanks.

Note: Refer to page 33 for sanitizing syrup tanks.

Step 2Calibrating the syrup flow: Calibrating the syrupflow must be done on a daily basis. It is vital that thecorrect amount of syrup be incorporated into the mixto obtain a quality shake. The cause of too thin shakesis often too much syrup. The cause of too thick shakesis often too little syrup.

To determine the rate of syrup flow, you will need acalibrating cup indicating fl. ounces. The proper rate ofsyrup flow is 1 fl. ounce (29.6 ml.) of syrup in 6seconds. Once this rate is set, the correct amount ofsyrup will be blended with the shake base regardlessof the size of shake served.

Press the corresponding flavor button for the syrupbeing calibrated.

Hold anempty cupbeneath the spinner housing.Pressthe CALIBRATE key. A message will appear on theLCD.

SYRUP SYSTEM PRESSAUTO -- -- -- START CALWASH -- -- -- CONTINUOUSCAL -- -- -- STOP

Press the WASH key. This will bleed any air pocketsfrom the syrup line.

When a steady stream of syrup is flowing into the cup,press the CALIBRATE key to stop the syrup flow.Discard the syrup in the cup.

Hold the calibration cup under the spinner housing.Press the CALIBRATE key. Press the AUTO key tocheck the rate of syrup flow. After 6 seconds the flowof syrup will automatically stop. If the amount of syrupreceived is 1 fl. ounce (29.6 ml.), the syrup is properlycalibrated.

Step 3Adjusting thesyruppressure: If the amount of syrupreceived is less than 1 fl. ounce (29.6 ml.), the syruppressure must be increased. If the amount received ismore than 1 fl. ounce (29.6 ml.), the pressure must bedecreased.

Inside the syrup compartment is an air pressuremanifold with individual regulators to control theamount of pressure to each tank and syrup line.

If less than 1 fl. ounce (29.6 ml.) is received, thepressure must be increased. Loosen the lock nut.Using a flat blade screwdriver, turn the adjusting screwclockwise.

Verify syrup calibration. Tighten the lock nut after thecorrect calibration is achieved.

Page 35: 0 h60 manual

31Model H60 Operating Procedures

If more than 1 fl. ounce (29.6 ml.) of syrup is received,the pressure must be decreased. Loosen the lock nutand turn the adjusting screw counterclockwise to zero.Remove the air line to the syrup tank to allow thepressure in the tank to dissipate. Reconnect the airline. Adjust the regulator to the new pressure settingand verify the syrup calibration. Tighten the lock nut.

Repeat the calibration procedures for each additionalsyrup line.

Important: When syrup calibration is complete, holdan empty calibration cup under the spinner housing.Press the RINSE key to rinse the spinner housing.

Note: Refer to page 34 for sanitizing syrup lines.

THIS PROCEDURE MUST BE PERFORMEDWEEKLY!

Manual Brush Cleaning

THIS PROCEDURE MUST BE PERFORMEDEVERY TWO WEEKS.

ALWAYS FOLLOW LOCAL HEALTH CODES.

To disassemble your unit, the following items will beneeded:

S Two cleaning pailsS Necessary brushes (provided with freezer)S Cleaning solutionS Single service towels

Draining Product From The FreezingCylinder

Step 1Press the AUTO key, cancelling compressor andbeater motor operation.

Step 2Remove the spinner blade and spinner housing fromthe freezer door. Take these parts to the sink forcleaning.

Step 3Remove the hopper cover, agitator, and assembled airtube from the mix hopper. Take these parts to the sinkfor cleaning.

Step 4With a pail under the door spout, press theWASH key.Open the draw valve and drain the remaining productfrom the freezing cylinder and mix hopper.

Figure 35

Step 5When the flow of product stops, press the WASH key,cancelling the wash cycle and close the draw valve.Discard this product.

Rinsing

Step 1Pour two gallons (7.6 liters) of cool, clean water intothe mix hopper. With the brushes provided, scrub themix hopper, mix level sensing probes, the outside ofthe agitator housing, and the mix inlet hole.

Figure 36

Page 36: 0 h60 manual

32 Model H60Operating Procedures

080627

Step 2With a mix pail beneath the door spout, press theWASH key.

Step 3Open the draw valve on the freezer door. Drain all therinse water from the door spout, close the draw valve,and press the WASH key cancelling the wash cycle.

Repeat this procedure until the rinse water beingdrawn from the freezing cylinder is clear.

Hopper Cleaning

Step 1Prepare an approved 100 PPM cleaning solution(examples: 2--1/2 gal. [9.5 liters] of Kay--5R or 2gal. [7.6 liters] of Stera--SheenR). USE WARMWATER AND FOLLOW THE MANUFACTURER’SSPECIFICATIONS.

Step 2Pour the cleaning solution into the hopper and allow itto flow into the freezing cylinder.

Step 3While the solution is flowing into the freezing cylinder,brush clean the mix hopper, mix level sensing probes,the outside of the agitator housing, and mix inlet hole.

Step 4Press the WASH key and allow the cleaning solutionin the freezing cylinder to agitate for five minutes.

Step 5Place an empty pail beneath the door spout.

Step 6Open the draw valve on the freezer door and draw offall the solution.

Step 7Once the cleaner stops flowing from the door spout,close the draw valve and press the WASH keycancelling wash cycle.

Disassembly

Note: Failure to remove parts, brush clean and thenair dry these parts, will result in damage to the relatedparts. These parts must be removed every 14 days orthe machine will lock--out and will not operate in theAUTO mode.

BE SURE THE CONTROL SWITCH IS INTHE OFF POSITION. Failure to do so may causeinjury from electrocution or hazardous moving parts.

Step 1Lift out the torque arm. Disengage the draw arm fromthe draw valve bracket and rotate the bracket to theright.

Step 2Remove the handscrews, freezer door, torque rotorassembly, beater, scraper blades, and drive shaft fromthe freezing cylinder. Take these parts to the sink forcleaning.

Hint: If the guide bearing is not connected to the endof the torque rotor shaft, it is still lodged in the beaterdrive shaft. To remove the guide bearing, insert thetorque arm into the side hole of the drive shaft andpush the bearing forward.

Step 3Remove the front drip tray and splash shield.

Brush Cleaning

Step 1Prepare a sink with an approved cleaning solution(examples: Kay--5R or Stera--SheenR). USEWARM WATER AND FOLLOW THEMANUFACTURER’S SPECIFICATIONS.

If an approved cleaner other than Kay--5R orStera--SheenR is used, dilute according to labelinstructions. IMPORTANT: Follow label directions, astoo STRONG of a solution can cause parts damage,while too MILD of a solution will not provide adequatecleaning. Make sure all brushes provided with thefreezer are available for brush cleaning.

Page 37: 0 h60 manual

33Model H60 Operating Procedures

Step 2Remove the:

S Seal from the drive shaftS O--rings and guide bearing from the torque

rotorS Draw valve from the freezer doorS O--rings from the draw valveS Spinner bearing from the draw valveS Gasket and front bearing from the freezer

door.

Note: To remove o--rings, use a single service towelto grasp the o--ring. Apply pressure in an upwarddirection until the o--ring pops out of its groove. Withthe other hand, push the top of the o--ring forward, andit will roll out of the groove and can be easily removed.If there is more than one o--ring to be removed, alwaysremove the rear o--ring first. This will allow the o--ringto slide over the forward rings without falling into theopen grooves.

Step 3Remove the o--rings from the inner andouter air tubes.

Step 4Return to the freezer with a small amount of cleaningsolution. With the black bristle brush, brush clean therear shell bearing at the back of the freezing cylinder.

Figure 37

Step 5Remove the rear drip pan from the front panel and taketo the sink for cleaning.

Note: If the drip pan is filled with an excessive amountof mix, refer to the Troubleshooting Guide.

Step 6Thoroughly brush clean all disassembled parts in thecleaning solution,making sure all lubricant andmix filmis removed. Take particular care to brush clean thedraw valve core in the freezer door. Place all thecleaned parts on a clean dry surface to air--dryovernight.

Step 7Wipe clean all exterior surfaces of the freezer.

Sanitizing the Syrup System

Twomain objectives in your cleaning proceduresmustbe to:

1. Discard all syrup at least once a week.

2. Flush the syrup lines at least once a week.

This must be performed on a regular basis (a) to keepa build--up of old syrup from clogging the lines, and (b)to break the bacteria chainwhich develops in the tanksand lines.Remember:Calibrating the syrup flowmustbe done every morning, especially after flushing thesyrup lines.

Step 1Sanitizing the syrup tanks. Pull back on the collar ofthe quick disconnect fitting of the air line. Allow the airpressure to dissipate from the syrup tank. Disconnectthe syrup line.

Remove the syrup tank from its compartment.Remove the syrup tank lid by lifting up on the lockinglever, and discard the remaining syrup.

Rinse the syrup tank with clean warm water.

Prepare one--half gallon (1.9 liters) of therecommended sanitizing solution with warm water inthe syrup tank. Brush clean the inside and outside ofthe tank. Remove syrup line fitting. Remove the diptube and o--ring from the syrup tank.

Thoroughly brush clean the dip tube, syrup line fitting,and o--ring using the sanitizing solution. Reassemblethe dip tube, o--ring, and syrup line fitting.

Page 38: 0 h60 manual

34 Model H60Operating Procedures

Pour off all sanitizing solution and place the tank in anupside--down position on a clean dry surface to air dry.

Repeat this procedure for all the syrup tanks.

Step 2Sanitizing the syrup lines. Prepare one gallon (3.8liters) of the recommended sanitizing solution withwarm water in a spare syrup tank. Replace and lockthe tank lid into position. Place this tank in the syrupcompartment.

Connect one of the air lines and the correspondingsyrup line to the syrup tank filled with sanitizingsolution.

Place the power switch in the ON position.

Press the corresponding flavor button for the syrup linebeing sanitized.

Place an empty pail beneath the spinner housing.Press the CALIBRATE key. A message will appear onthe LCD.

Press the WASH key. Flush the syrup line until thesolution runs clear. Press the CALIBRATE key to stopthe flow of sanitizing solution.

Note: This procedure will thoroughly clean the endsof the syrup lines that attach to the spinner housing toprevent bacteria build--up.

Turn the syrup tank with the sanitizing solutionupside--down. Press the CALIBRATE key. Press theWASH key to clear the syrup line of any remainingsanitizer. When the sanitizer has been flushed fromthe syrup lines, press theCALIBRATEkey to completethis step.

Repeat this procedure for all syrup lines.

The fourth syrup line is for the spinner rinse. Press theRINSE key to further flush this rinse line. Place thepower switch to the OFF position.

Page 39: 0 h60 manual

35Model H60 Important: Operator Checklist

051208

Section 7 Important: Operator Checklist

During Cleaning and Sanitizing

ALWAYS FOLLOW LOCAL HEALTH CODES.

Cleaning and sanitizing schedules are governedby federal, state, or local regulatory agencies,and must be followed accordingly. The followingcheck points should be stressed during thecleaning and sanitizing operations.

CLEANING AND SANITIZING MUST BEPERFORMED EVERY TWO WEEKS.

Troubleshooting Bacterial Count

j 1. Thoroughly clean and sanitize the machineregularly, including complete disassembly andbrush cleaning.

j 2. Use all the brushes supplied for thoroughcleaning. The brushes are specially designed toreach all the mix passageways.

j 3. Use the white bristle brush to clean the mix inlethole which extends from the mix hopper downto the rear of the freezing cylinder.

j 4. Use the black bristle brush to thoroughly cleanthe rear shell bearing located at the rear of thefreezing cylinder. Be sure to have a generousamount of cleaning solution on the brush.

j 5. Properly prepare the cleaning and sanitizingsolutions. Read and follow the label directionscarefully. Too strong of a solution may damagethe parts and too weak of a solution will not doan adequate job of cleaning or sanitizing.

j 6. Empty all syrup from the tanks and discard atleast once a week.

j 7. Thoroughly clean and sanitize the syrup lines atleast once a week.

j 8. The temperature of the mix in the mix hopperand the walk--in cooler should be below 40_F.(4.4_C.).

Regular Maintenance Checks

j 1. Rotate the scraper blades to allow both sides ofthe knife edge to wear evenly. This willcontribute to self--sharpening and helpmaintainfast, efficient freezing.

j 2. Replace scraper blades that are bent,damaged, or worn down. Before installingbeater, be certain that the scraper blades areproperly attached over the beater pins.

j 3. Check the rear shell bearing for signs of wear(excessive mix leakage in rear drip pan) and becertain it is properly cleaned.

j 4. Using a screwdriver and cloth towel, keep therear shell bearing and the female hex drivesocket clean and free of lubricant and mixdeposits.

j 5. Dispose of o--rings and seals if they are worn,torn, or fit too loosely, and replace with newones.

j 6. Follow all lubricating procedures as outlined in“Assembly”.

j 7. On air--cooled units, check the condenser foraccumulation of dirt and lint. A dirty condenserwill reduce the efficiency and capacity of themachine. The condenser should be cleanedmonthly with a soft brush. Never usescrewdrivers or other metal probes to cleanbetween the fins.Note: For machines equipped with an air filter,it will be necessary to vacuum clean the filterson a monthly schedule.

j 8. On water cooled units, check the water lines forkinks or leaks. Kinks can occur when themachine is moved back and forth for cleaningormaintenance purposes. Deteriorated orcracked water lines should be replaced only byan authorized Taylor mechanic.

Page 40: 0 h60 manual

36 Model H60Important: Operator Checklist

080627

Winter Storage

If the placeof business is to be closedduring thewintermonths, it is important to protect the freezer byfollowing certain precautions, particularly if thebuilding is subject to freezing conditions.

On water cooled freezers, disconnect the watersupply. Relieve pressure on spring in water valve. Useair pressure on the outlet side to blow out any waterremaining in the condenser. This is extremelyimportant. Failure to follow this procedure may causesevere and costly damage to the refrigeration system.

Disconnect the freezer from the main power source toprevent possible electrical damage.

Your local Taylor Distributor can perform this servicefor you.

Wrap detachable parts of the freezer (such as thebeater, blades, the drive shaft, and the freezer door)and place them in a dry, protected place. Rubber trimparts and gaskets can be protected by wrapping withmoisture--proof paper. All parts should be thoroughlycleaned of dried mix or lubrication accumulationswhich attract mice and other vermin.

Page 41: 0 h60 manual

37Model H60 Troubleshooting Guide

Section 8 Troubleshooting Guide

PROBLEM PROBABLE CAUSE REMEDY PAGEREF.

1. Soft lock messageappears on LCD.

a. More than 24 hours sincethe last heat cycle.

a. The freezer must gothrough a heat cycle every24 hours. The freezermust now bedisassembled and brushcleaned or placed in aheat cycle.

16

b. The power switch is in theOFF position.

b. The power switch must bein the ON position. Thefreezer must now bedisassembled and brushcleaned or placed in aheat cycle.

16

c. The freezer is not in theAUTO or STANDBYmode.

c. The freezer must be in theAUTO or STANDBYmode. The freezer mustnow be disassembled andbrush cleaned or placed ina heat cycle.

16

d. Mix out condition. d. The level of mix in the mixhopper must be above theMIX OUT probe beforestarting the heat cycle.The freezer must now bedisassembled and brushcleaned or placed in aheat cycle.

16

e. The agitator is notinstalled.

e. The agitator must becleaned and installedbefore starting the heatcycle. The freezer mustnow be disassembled andbrush cleaned.

28

f. The agitator is notrotating.

f. The agitator must becleaned before startingthe heat cycle.Disassemble the freezerand brush clean.

28

Page 42: 0 h60 manual

38 Model H60Troubleshooting Guide

PROBLEM PROBABLE CAUSE REMEDY PAGEREF.

2. Hard lock messageappears on LCD.

a. There has been athermistor failure (freezingcylinder, hopper, or glycol)during the heat treatmentprocess.

a. The freezer must bedisassembled and brushcleaned.

15

b. More than 14 days sincelast brush cleaning.

b. The freezer must bedisassembled and brushcleaned every 14 days.

15

3. No product beingdispensed with draw valveopen and machine in theAUTO mode.

a. There is a freeze--up inthe mix inlet hole.

a. Call a service technicianto adjust hoppertemperature.

------

b. The assembled air tubesare installed incorrectly.

b. Install in the mix inlet hole,using the end with thehole in it. Pin on inner airtube must be positioned atthe bottom of notch in theouter air tube.

27

c. Beater rotatingcounter--clockwise.

c. Contact service technicianto correct rotation toclockwise.

------

d. There is an inadequateamount of mix in thehopper.

d. Fill the hopper with mix. 26

4. The product is too stiff. a. Improper lubrication oftorque rotor o--rings.

a. Lubricate the o--ringsproperly.

21

b. Improper consistencycontrol adjustment.

b. Product, with no syrupblended (vanilla), shouldbe dispensed at 26_ to28_F. (--3.3_ to --2.2_C.).

13

c. The torque rotor isbinding.

c. Before installing thetorque arm, check to seeif the torque rotor can berotated freely withoutbinding.

24

d. Not enough syrup is beingblended with product.

d. Calibrate the syrupsystem. Syrup deliveryshould be 1 oz. (29.6 ml)in six seconds.

30

e. Torque arm not installed. e. Install torque arm. 24

Page 43: 0 h60 manual

39Model H60 Troubleshooting Guide

PROBLEM PROBABLE CAUSE REMEDY PAGEREF.

5. The product is too soft. a. Improper consistencycontrol adjustment.

a. Product, with no syrupblended (vanilla), shouldbe dispensed at 26_ to28_F. (--3.3_ to --2.2_C.).

13

b. The torque rotor isbinding.

b. Before installing thetorque arm, check to seeif the torque rotor can berotated freely withoutbinding.

21

c. Improper lubrication oftorque rotor o--rings.

c. Lubricate the o--ringsproperly.

22

d. Lubrication of torque rotorguide bearing.

d. Do not lubricate the guidebearing.

21

e. Too much syrup is beingblended with product.

e. Calibrate the syrupsystem. Syrup deliveryshould be 1 oz. (29.6 ml)in six seconds.

30

f. Not enough air spacearound unit (air--cooled).

f. Allow for adequate air flowacross the condenser.

2

g. The scraper blades areworn.

g. Replace regularly. 35

h. Dirty condenser(air--cooled)

h. Clean regularly. 35

i. The mix is out--of--date. i. Use only fresh mix. 27

j. Loss of condensercooling.

j. Locate cause of waterloss and correct.

------

6. Large pressureadjustments arenecessary to receive 1 fl.oz. (29.6 ml) in sixseconds.

a. There is hardened syrupin the syrup line.

a. Clean and sanitize thesyrup lines once a week.

33

b. The syrup line and the airline are not matchedproperly to the syrup tank.

b. Match the syrup and theair lines to the syrup tank.

30

7. The mix in the hopper istoo cold.

a. The temperature is out ofadjustment.

a. Call a service technicianto adjust hoppertemperature.

------

8. The mix in the hopper istoo warm while in theAUTO mode.

a. The temperature is out ofadjustment.

a. Call a service technicianto adjust hoppertemperature.

------

b. The hopper cover is not inposition.

b. Place the cover inposition.

27

Page 44: 0 h60 manual

40 Model H60Troubleshooting Guide

PROBLEM PROBABLE CAUSE REMEDY PAGEREF.

9. The drive shaft is stuck inthe gear box coupling.

a. Rounded corners of driveshaft, coupling, or both.

a. Call service technician tocorrect cause and replacethe necessarycomponents. Do notlubricate end of driveshaft.

20

b. Mix and lubricant collectedin the drive coupling.

b. Brush--clean rear shellbearing area regularly.

35

10. The freezing cylinder wallsare scored.

a. The beater assembly isbent.

a. Call a service technicianto repair or replace beaterand to correct cause ofinsufficient mix in freezingcylinder.

------

b. The front bearing ismissing or worn.

b. Install or replace frontbearing.

22

c. The gear box is out ofalignment.

c. Call a service technicianto realign gear box.

------

d. The beater pins arebroken.

d. Call service technician torepair or replace.

35

11. Excessive mix leakagefrom the dispensing spout.

a. The draw valve o--ringsare worn or missing.

a. Replace regularly. 42

b. There is unadequatelubrication on the drawvalve o--rings.

b. Lubricate properly. 22

c. The wrong type oflubricant was being used(Example: petroleum baselubricant).

c. Use food grade lubricant(Example: Taylor LubeHigh Performance).

20

12. Excessive mix leakageinto the rear drip pan.

a. Worn or missing seal ondrive shaft.

a. Replace regularly. 35

b. Inadequate lubrication ofdrive shaft.

b. Follow lubricationprocedures in “Assembly”.

20

c. Bad rear shell bearing. c. Call service technician toreplace rear shell bearing.

------

d. Drive shaft and beaterworking forward.

d. Call service technician. ------

e. Seal installed inside--outon drive shaft.

e. Install correctly. 20

Page 45: 0 h60 manual

41Model H60 Troubleshooting Guide

PROBLEM PROBABLE CAUSE REMEDY PAGEREF.

13. No freezer operation afterplacing unit in the AUTOmode.

a. Unit unplugged. a. Plug into wall receptacle. ------

b. Circuit breaker off orblown fuse.

b. Turn circuit breaker on orreplace fuse.

------

c. Beater motor out on reset. c. Clear the tone and resetfreezer.

13

d. Compressor off on highpressure cut out.

d. Clear the tone. Place unitin the AUTO mode. Ifproblem persists, contactservice technician.

17

e. Water turned off(water--cooled units.)

e. Re--establish watersupply.

------

14. Water continues to flowthrough spinner housing.

a. Rinse solenoid stuckopen.

a. Call service technician forrepair.

------

15. Spinner shaft will notrotate to blend syrup intoproduct.

a. Flexible cable broken. a. Call service technician toreplace cable.

------

b. Pin missing in femalequick disconnect.

b. Call service technician toreplace disconnect.

------

16. Liquid Crystal Display isblank after power switch isplaced in the ON position.

a. Unit unplugged. a. Plug into wall receptacle. ------

b. Circuit breaker off orblown fuse.

b. Turn circuit breaker on orreplace fuse.

------

c. Screen intensity out ofadjustment.

c. Call service technician toadjust.

------

17. Product not feeding intofreezing cylinder.

a. Inadequate mix in hopper. a. Fill hopper with mix. 26

b. Mix inlet hole frozen up. b. Hopper temperatureneeds adjustment. Callservice technician.

------

c. Assembled air tubesinstalled incorrectly.

c. Install in mix inlet hole,using end with the hole init. Pin on inner air tubemust be positioned at thebottom of the notch in theouter air tube.

27

Page 46: 0 h60 manual

42 Model H60Parts Replacement Schedule

Section 9 Parts Replacement Schedule

PART DESCRIPTION EVERY 3 MONTHS EVERY 6 MONTHS ANNUALLY QTY.

Drive Shaft Seal X 1

Scraper Blades X 2

Freezer Door Gasket X 1

Front Bearing X 1

Draw Valve O--Rings X 2

Torque Rotor Guide Bearing X 1

Torque Rotor O--Rings X 2

Inner Air Tube O--Rings X 3

Outer Air Tube O--Rings X 2

Double Ended Brush Inspect & Replace ifNecessary

Minimum 1

Black Bristle Brush, 1” x 2” Inspect & Replace ifNecessary

Minimum 1

White Bristle Brush, 1--1/2” x 2” Inspect & Replace ifNecessary

Minimum 1

White Bristle Brush, 3” x 7” Inspect & Replace ifNecessary

Minimum 1

End Brush Inspect & Replace ifNecessary

Minimum 1

Page 47: 0 h60 manual

Section 10 Parts List

43

+ Available Separately

Model H60 Parts List

DESCRIPTION

PART

NUMBER

H60

QTY.

WARR.

CLASS

REMARKS

PARTS

UPDATE

AC

CU

MU

LATO

RA

.-AIR

*547

2*P

RTL

X46

916

110

3FI

TTIN

GA

.-AIR

AC

CU

MU

LATO

RX

4854

81

103

J501

0000

/UP

90+

TUB

E-V

INY

L1/

8ID

X1/

16W

ALL

0209

38-6

100

0A

CC

UM

ULA

TOR

A.-G

LYC

OL

*H60

*X

4665

01

103

J401

9999

/PR

IOR

(RE

PLA

CE

DW

/TA

NK

-GLY

CO

L)79

+B

OO

T-G

YLC

OL

AC

CU

MU

LATO

R04

2150

100

0J4

0199

99/P

RIO

R79

AD

AP

TOR

A.-C

AS

TER

X18

915

410

3A

GIT

ATO

RA

.*H

T*20

QT

HO

PP

ER

X44

797

110

3A

RM

-TO

RQ

UE

0145

001

103

BE

AR

ING

-FR

ON

T01

3116

100

0B

EA

RIN

G-G

UID

E01

4496

100

0B

EA

RIN

G-R

EA

RS

HE

LL*N

ICK

.PLA

TE03

1324

100

0+

GU

IDE

-DR

IPS

EA

L02

8992

100

0+

NU

T-B

RA

SS

BE

AR

ING

0289

911

000

+W

AS

HE

R-B

EA

RIN

GLO

CK

0128

641

000

BE

AR

ING

-SY

RU

PC

AB

.DO

OR

*547

2*04

5339

200

0B

EA

TER

A.-7

QT-

1P

IN-S

UP

PO

RT

X46

233

110

3+

BLA

DE

-SC

RA

PE

R-P

LAS

TIC

9-13

/16L

0462

372

000

+C

LIP

-SC

RA

PE

RB

LAD

E04

6238

200

0B

ELT

-RD

3/16

WX

4.95

ID03

6162

100

0A

GIT

ATO

RB

ELT

-V-4

L370

0042

271

000

60H

zB

LAD

EA

.-SP

INN

ER

*83/

8IN

CH

*X

3557

01

103

BLO

CK

-TE

RM

INA

L2

PO

LE03

9422

110

31

PH

AS

EB

LOC

K-T

ER

MIN

AL

3P

OLE

0394

231

103

3P

HA

SE

+S

CR

EW

8X

11/

4R

DH

D03

9420

200

0FO

R03

9422

&03

9423

TER

MIN

AL

BLO

CK

BLO

CK

-TE

RM

INA

L5

PO

LE02

4329

110

3B

LOC

K-T

ER

MIN

AL-

PLU

G10

P.2

SIP

0403

22-0

051

103

BLO

CK

-TE

RM

INA

L-P

LUG

6P.2

SIP

0403

22-0

021

103

BLO

CK

-TE

RM

INA

L-P

LUG

7P.2

SIP

0403

22-0

032

103

BLO

CK

-TE

RM

INA

L-P

LUG

8P.2

SIP

0403

22-0

042

103

ModelH60

Page 48: 0 h60 manual

+ Available Separately

44Parts List Model H60

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

H60

QTY.

PART

NUMBER

BR

US

H-D

OU

BLE

EN

DE

D-P

UM

P&

FEE

DTU

BE

0130

721

000

BR

US

H-D

RA

WV

ALV

E1-

1/2”

OD

X3”

0147

531

000

BR

US

H-E

ND

-DO

OR

-SP

OU

T-S

S-H

T03

9719

100

0B

RU

SH

-MIX

PU

MP

BO

DY

-3”X

7”W

HIT

E02

3316

100

0B

RU

SH

-RE

AR

BR

G1I

N.D

X2I

N.L

GX

1401

3071

100

0B

US

HIN

G-S

YR

UP

CA

B.D

OO

R*5

472*

0453

402

000

CA

BLE

-RIB

BO

N-1

0C-3

4”L-

DIL

/DIL

0400

40-0

231

103

J3IC

TOP

CB

LED

CA

BLE

-RIB

BO

N-1

0C-5

”L-D

IL/D

IL04

0040

-024

110

3LE

DTO

LED

CA

BLE

-RIB

BO

N-1

4C-1

4”L

SIP

/SIP

R04

0040

-015

110

3LC

DTO

J9U

CC

AB

LE-R

IBB

ON

-20C

-41”

-DIL

/DIL

0400

40-0

461

103

J2U

CTO

J12I

FC

AB

LE-R

IBB

ON

-20C

-43”

L-D

IL/D

IL04

0040

-045

110

3J7

UC

TOJ9

IFC

AB

LE-R

IBB

ON

-50C

-35”

L-D

IL/D

IL04

0040

-044

110

3J1

0UC

TOJ2

IFC

AB

LE-2

CO

ND

-#22

SH

IELD

ED

0451

54-4

01

103

PO

WE

RC

AB

LEIF

-UC

(BU

LKP

/NR

6003

001)

CA

P-C

AP

AC

ITO

R1-

7/16

DTO

PLE

AD

0202

471

103

CA

P-M

AG

NE

T*H

T*04

4796

110

3C

AP

-GLY

CO

L(O

LD)

0351

791

103

J401

9999

/PR

IOR

79C

AP

-GLY

CO

L(N

EW

)04

7314

-11

103

J402

0000

/UP

79C

AP

AC

ITO

R-R

UN

-.8

UF/

400V

0394

821

103

AG

ITA

TOR

CA

PA

CIT

OR

-RU

N-

4UF-

370V

0196

241

103

FAN

MO

TOR

CA

PA

CIT

OR

-RU

N-5

UF

450

VO

LT05

4327

110

3K

0117

660

SP

INN

ER

MO

TOR

153

CA

PA

CIT

OR

-STA

RT-

21-2

5UF/

220V

0202

461

103

K01

1765

9/P

RIO

RS

PIN

NE

RM

OTO

R01

6005

-C

AR

D-D

AIL

YC

LEA

N-H

T-S

HK

0467

011

000

CA

STE

R-S

WV

5/8

STE

M4I

NW

HE

EL

0187

944

103

CH

AR

T-FL

IP05

0716

100

0C

LAM

P-H

OS

E14

000

J402

0000

/UP

79C

OM

PR

ES

SO

RA

H75

13Z-

AH

245E

T(T

EC

UM

SE

H)

0475

20-

151

2J4

0636

83/U

P8/

25/9

9U

SE

-**F

83

+C

AP

AC

ITO

R-R

UN

-35U

F-37

0V(2

30-6

0-1)

0294

391

103

J406

3683

/UP

83+

CA

PA

CIT

OR

-STA

RT-

124-

149U

F/33

(230

-60-

1)04

8134

110

3J4

0636

83/U

P83

+G

RO

MM

ET-

CO

MP

RE

SS

OR

MO

UN

TIN

G03

9923

400

0J4

0636

83/U

P83

ModelH60

Page 49: 0 h60 manual

45

+ Available Separately

Model H60 Parts List

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

H60

QTY.

PART

NUMBER

+R

ELA

Y-S

TAR

T-C

OM

PR

ES

SO

R(2

30-6

0-1)

0481

501

103

J406

3683

/UP

83+

SLE

EV

E-C

OM

P.M

OU

NTI

NG

0399

244

000

J406

3683

/UP

83+

VA

LVE

-AC

CE

SS

1/4F

LX5/

16S

DR

-90

0530

271

103

US

EW

ITH

FRE

NC

HB

UIL

TC

OM

PR

ES

SO

RC

OM

PR

ES

SO

RM

51B

143B

BC

A(B

RIS

TOL)

0368

80-

151

2J4

0636

82/P

RIO

R83

+C

AP

AC

ITO

R-R

UN

-25

UF/

440V

(230

-60-

1)03

7431

110

3J4

0636

82/P

RIO

R83

+C

AP

AC

ITO

R-S

TAR

T-16

1-19

3UF/

250V

(230

-60-

1)03

1790

110

3J4

0636

82/P

RIO

R83

+G

RO

MM

ET-

CO

MP

RE

SS

OR

MO

UN

TIN

G03

7428

400

0J4

0636

82/P

RIO

R83

+R

ELA

Y-S

TAR

T-C

OM

PR

ES

SO

R(2

30-6

0-1)

0374

301

103

J406

3682

/PR

IOR

83+

SLE

EV

E-C

OM

P.M

OU

NTI

NG

0374

294

000

J406

3682

/PR

IOR

83C

OM

PR

ES

SO

R-A

IR03

2129

-27

110

3+

SW

ITC

H-P

RE

SS

UR

E01

6308

110

3+

VA

LVE

-CH

EC

K1/

4MP

0209

591

103

+TU

BE

-.170

IDX

.250

OD

0758

85-1

41

000

+TU

BE

-.170

IDX

.250

OD

0758

85-1

81

000

CO

ND

EN

SE

R-A

C-1

2LX

18H

X4.

3-5R

OW

0195

581

103

CO

UP

LIN

GA

.-DR

IVE

-SP

INN

ER

X17

106

110

3P

IN-R

OLL

-.094

DX

.562

L01

5971

100

0C

OV

ER

-CO

NTR

OL

BO

X04

6667

110

3J4

0299

99/P

RIO

R82

CO

VE

R-C

ON

TRO

LB

OX

0475

581

103

J403

0000

/UP

82C

OV

ER

-HO

PP

ER

CO

MP

LETE

053809

110

3R

EP

LAC

ES

X42

628/

0254

29/0

4261

9/04

3295

KN

OB

-MIX

CO

VE

R02

5429

110

3U

SE

DW

ITH

X42

628

OLD

STY

LEC

OV

ER

RE

TAIN

ER

-HO

PP

ER

CO

VE

R04

2619

210

3U

SE

DW

ITH

X42

628

OLD

STY

LEC

OV

ER

SC

RE

W-8

-32

X1/

2O

VA

LH

D-S

S04

3295

800

0U

SE

DW

ITH

X42

628

OLD

STY

LEC

OV

ER

CU

P-D

IVID

ED

SY

RU

P01

7203

100

0D

EC

AL-

DA

ILY

CLE

AN

ING

-HT-

SH

-H60

0466

981

000

DE

CA

L-D

EC

-TA

YLO

R-H

6005

2281

100

0J9

0400

00/U

P14

1D

EC

AL-

DE

C-T

AY

LOR

-H60

(OLD

)04

6178

100

0P

RIO

RTO

J904

0000

141

DE

CA

L-M

AN

UA

LC

LEA

NIN

G-H

T-H

6004

6699

100

0D

EC

AL-

SE

T4

SY

RU

PFL

AV

OR

0215

231

000

ModelH60

Page 50: 0 h60 manual

+ Available Separately

46Parts List Model H60

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

H60

QTY.

PART

NUMBER

DE

CA

L-S

YR

UP

FLA

VO

RIN

STR

UC

TIO

N02

0997

100

0D

EC

AL-

TRO

UB

LES

HO

OTI

NG

0383

741

000

DIA

GR

AM

-WIR

ING

*H60

*04

6638

-1

000

DIS

PLA

Y-L

IQU

IDC

RY

STA

LX

3806

2-S

ER

110

3D

OO

RA

.-PA

RTI

AL-

1S

PT

X17

373

110

3+

BE

AR

ING

-FR

ON

T01

3116

100

0+

BE

AR

ING

-SP

INN

ER

*452

*01

7032

100

0+

VA

LVE

A.-D

RA

W*H

60*

X54

821

1K

1013

585

RE

PLA

CE

SX

4667

1+

O-R

ING

-1-1

/16

OD

X.1

39W

0130

292

DO

OR

A.-S

YR

UP

CA

BIN

ET

X45

325

110

3D

RY

ER

-FIL

TER

3/8

X1/

4S

OLD

ER

0458

661

000

J406

3682

/PR

IOR

83D

RY

ER

-FIL

TER

-HP

623/

8X

1/4

S04

8901

100

0J4

0636

83/U

P(R

EP

LAC

ES

0475

21)

83FA

STE

NE

R-C

LIP

1/4-

20U

-TY

PE

0458

6510

000

PA

NE

LS&

SY

RU

PC

AB

FILT

ER

-CO

RC

OM

6EH

104

0140

-001

210

3Q

TYFI

LTE

R-IN

LIN

E-G

LYC

OL-

40M

ICR

ON

0416

701

103

+B

OO

T-G

LYC

OL

FILT

ER

0421

321

000

J401

9999

/PR

IOR

79+

BO

OT-

GLY

CO

LFI

LTE

R04

7490

100

0J4

0200

00/U

P79

FITT

ING

-QD

FEM

ALE

PA

NE

LM

OU

NT

0362

954

103

SY

RU

P/R

INS

ELI

NE

SFI

TTIN

G-Q

DM

ALE

INS

ER

T03

6296

410

3S

YR

UP

/RIN

SE

LIN

ES

+O

-RIN

G5/

16O

DX

.070

W01

6272

400

0FL

UID

-HE

AT

TRA

NS

FER

X39

667

100

01

GA

LLO

NFU

SE

-15

AM

P-IN

LIN

E-N

ON

DE

LAY

0452

931

000

GA

SK

ET-

DO

OR

5.17

7ID

X5.

938O

D01

6672

100

0G

AS

KE

T-S

YR

UP

DO

OR

0453

261

000

GE

AR

A.*R

ED

UC

ER

-AG

ITA

TOR

0479

881

103

AG

ITA

TOR

MO

TOR

GE

AR

A.*R

ED

UC

ER

0122

351

212

GR

OM

ME

T-R

IBB

ON

CA

BLE

0449

991

000

FRO

NT

PA

NE

LG

UID

EA

.-DR

IPP

AN

*H60

*X

4664

81

103

J406

3682

/PR

IOR

83G

UID

EA

.-DR

IPP

AN

*H60

*X

4790

01

103

J406

3683

/UP

83H

EA

TER

A.-G

LYC

OL

*H60

*X

4666

6-1

103

J401

9999

/PR

IOR

79H

EA

TER

A.-G

LYC

OL

X47

331-

110

3J4

0200

00/U

P79

ModelH60

Page 51: 0 h60 manual

47

+ Available Separately

Model H60 Parts List

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

H60

QTY.

PART

NUMBER

THE

RM

OS

TAT-

HIL

IMIT

0357

861

103

HO

LDE

R-F

US

E-IN

LIN

E-T

YP

EH

LR04

5606

110

3H

OS

E-R

UB

BE

R5/

16ID

x9/

16O

D(G

LYC

OL

SY

STE

M)

0473

40-

700

0(B

ULK

-R50

2011

)J40

2000

0/U

P79

HO

US

ING

-SP

INN

ER

*4S

PIG

OT*

452*

0172

691

103

+TU

BE

-VIN

YL

3/16

IDX

1/16

WA

LL02

0940

-62

000

BU

LK-1

00FT

R30

314

(SY

RU

PH

OU

SIN

G)

+TU

BE

-VIN

YL

3/16

IDX

1/16

WA

LL02

0940

-82

000

BU

LK-1

00FT

R30

314

(SY

RU

PH

OU

SIN

G)

HO

US

ING

A.-A

GIT

ATO

R*H

T*X

5166

41

103

CA

P-M

AG

NE

TH

T04

4796

110

3M

AG

NE

TA

.-AG

ITA

TOR

-INN

ER

X41

733

110

3S

CR

EW

-8-3

2X

3/16

ALL

EN

SE

T00

6812

200

0K

ITA

.-TU

NE

UP

X34

615

100

0O

-RIN

G-1

-1/1

6O

DX

.139

W01

3029

2D

RA

WV

ALV

EB

EA

RIN

G-F

RO

NT

0131

161

000

BE

AR

ING

-GU

IDE

0144

961

000

GA

SK

ET-

DO

OR

5.17

7ID

X5.

938O

D01

6672

100

0O

-RIN

G-.2

91ID

X.0

80W

0185

505

000

INN

ER

FEE

DTU

BE

O-R

ING

-.643

OD

X.0

77W

0185

722

000

OU

TER

FEE

DTU

BE

O-R

ING

-5/1

6O

DX

.070

W01

6272

400

0Q

DFI

TTIN

GO

-RIN

G-5

/8O

DX

.103

W01

6030

300

0S

YR

UP

LIN

ES

SE

AL-

DR

IVE

SH

AFT

0325

601

000

TOO

L-O

-RIN

GR

EM

OV

AL

0482

60-W

HT

100

0K

NO

B-D

RA

WV

ALV

E01

3635

110

3+

NU

T-LO

CK

KN

OB

0136

491

103

KN

OB

-AD

JUS

TME

NT

0144

991

103

+S

CR

EW

-AD

JUS

TME

NT

0144

981

103

LAB

EL-

CA

UTI

ON

-AG

ITA

TOR

0451

911

000

LAB

EL-

DO

OR

-WA

RN

0327

491

000

MO

VIN

GP

AR

TSLA

BE

L-E

LEC

.WA

RN

ING

SIN

GLE

0327

171

000

LAB

EL-

WA

RN

-CO

VE

R05

1433

800

0LE

NS

-DIS

PLA

Y03

8221

110

3

ModelH60

Page 52: 0 h60 manual

+ Available Separately

48Parts List Model H60

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

H60

QTY.

PART

NUMBER

+S

TAN

DO

FF-L

EN

S03

8225

400

0LI

P-D

RIP

-NO

SE

CO

NE

0364

351

000

LOU

VE

R-S

IDE

0136

311

103

LEFT

LUB

RIC

AN

T-TA

YLO

RH

IPE

RF-

4oz

TUB

E04

8232

100

0M

AN

-OP

ER

*H63

*04

8887

-M1

000

J504

0000

/UP

91M

AN

IFO

LDA

.-RE

GU

LATO

R*H

60*

X47

285

110

3D

EC

AL-

FLA

VO

RC

OLO

RS

ET

'4'

0221

051

000

FITT

ING

1/4

X.1

7090

DE

GR

EE

0759

461

000

GA

UG

E-P

RE

SS

UR

E0-

60P

SI1

/8M

PT

0278

753

103

LIN

EA

.-AIR

45D

EG

BA

RB

X47

043-

123

103

ELB

OW

-1/4

MP

TX

1/4B

AR

B-4

5D

EG

.04

6925

310

3FE

RR

ULE

-.475

IDN

PB

RA

SS

0210

826

000

SO

CK

ET-

Q.D

.CO

290

DE

G1/

4BA

RB

0215

243

103

TUB

E-N

YLO

BR

AD

E1/

4ID

X7/

16O

D02

0568

-12

300

0B

ULK

-100

FTR

3031

7N

IPP

LE-1

/4M

PT

X2

BR

AS

S07

5940

310

3P

LUG

-1/4

MP

BR

AS

S02

7747

200

0R

EG

ULA

TOR

-PR

ES

SU

RE

-CO

202

7744

410

3V

ALV

E-P

RE

SS

UR

E-R

ELI

EF-

45#

1/4M

PT

0472

521

103

J311

0000

/UP

76V

ALV

E-P

RE

SS

UR

E-R

ELI

EF-

45#

1/8M

PT

0211

481

103

J310

9999

/PR

IOR

76M

OTO

R-1

.0H

P01

3102

-1

212

CA

PA

CIT

OR

-STA

RT

0357

981

103

LEE

SO

N-2

30-6

0-1

CA

PA

CIT

OR

-RU

N03

6084

110

3LE

ES

ON

-230

-60-

1C

AP

AC

ITO

R-S

TAR

T03

3043

110

3M

AG

NE

TEK

-230

-60-

1C

AP

AC

ITO

R-R

UN

0330

471

103

MA

GN

ETE

K-2

30-6

0-1

MO

TOR

-1/5

HP

3050

RP

M05

4328

-1

103

K01

1766

0/U

PS

PIN

NE

R15

3M

OTO

R-1

/12

HP

3450

RP

M01

6005

-1

103

K01

1765

9/P

RIO

RS

PIN

NE

RM

OTO

R-A

GIT

ATO

R04

7987

-27

110

3+

BR

AC

KE

T-A

GIT

ATO

RM

OTO

R*H

T*03

7980

110

3M

OTO

R-F

AN

120

W20

8/23

0V04

1401

-1

103

60H

zO

NLY

+FA

N-4

BLA

DE

12”P

US

H26

DE

GC

W02

9771

110

3N

UT-

STU

D*G

EN

ER

AL

US

AG

E*

0215

084

103

ModelH60

Page 53: 0 h60 manual

49

+ Available Separately

Model H60 Parts List

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

H60

QTY.

PART

NUMBER

NY

LON

-SP

IRA

LW

RA

P-B

LUE

-2”

0415

82-4

100

0N

YLO

N-S

PIR

AL

WR

AP

-BR

OW

N-2

”04

1582

-11

000

NY

LON

-SP

IRA

LW

RA

P-R

ED

-2”

0415

82-2

100

0P

AIL

-MIX

10Q

T.01

3163

100

0P

AN

-DR

IP19

-1/2

LON

G03

5034

110

3P

AN

EL

A.-F

RO

NT

*H60

*X

4663

41

103

PA

NE

LA

.-SID

ELO

WE

R(L

EFT

)X

2439

71

103

J406

3682

/PR

IOR

83P

AN

EL

A.-S

IDE

LOW

ER

(RIG

HT)

X34

681

110

3J4

0636

82/P

RIO

R83

PA

NE

L-S

IDE

UP

PE

R(M

IDD

LELE

FT)

0245

761

103

J406

3682

/PR

IOR

83P

AN

EL-

SID

EU

PP

ER

(MID

DLE

RIG

HT)

0466

691

103

J402

9999

/PR

IOR

82P

AN

EL-

SID

EU

PP

ER

(MID

DLE

RIG

HT)

0475

571

103

J403

0000

-J40

6368

282

PA

NE

L-R

EA

RW

/LO

UV

ER

S02

6980

-SP

110

3P

AN

EL-

SID

E(L

EFT

)X

4828

51

103

J406

3683

/UP

84P

AN

EL-

SID

E(R

IGH

T)X

4828

61

103

J406

3683

/UP

84P

AN

EL-

SID

EU

PP

ER

(TO

PR

IGH

T)04

2317

110

3P

CB

A.-C

ON

TRO

L*H

60*U

VC

2(N

EW

)X

5341

8-S

ER

121

2J9

0426

52(R

epla

ces

X46

743-

SE

R)

141

Incl

udes

:P

CB

A.-U

VC

2X

5116

9-S

ER

121

2B

AS

EB

OA

RD

141

CH

IP-S

OFT

WA

RE

X40

783

110

314

1P

CB

A.-C

ON

TRO

L*H

60*(

OLD

)X

4674

3-S

ER

121

2R

EP

LAC

EW

/X53

418-

SE

R14

1/14

3In

clud

es:P

CB

A.-U

NIV

ER

SA

LC

ON

TRO

L64

KX

4486

3-S

ER

121

2B

AS

EB

OA

RD

CH

IP-S

OFT

WA

RE

X40

840

110

3P

CB

A.-I

NTE

RFA

CE

-HT-

BA

SE

X44

747-

SE

R1

212

NO

PE

RS

ON

ALI

TYB

OA

RD

-TO

RQ

UE

CO

NTR

OL

PC

BA

.-LE

D-4

PO

SIT

ION

X44

752-

SE

R2

103

PIN

-RE

TAIN

ING

-HO

PP

ER

CO

VE

R04

3934

410

3P

LATE

-HIN

GE

LOW

ER

0453

381

103

SY

RU

PC

AB

DO

OR

PLA

TE-H

ING

EU

PP

ER

0453

371

103

SY

RU

PC

AB

DO

OR

PLA

TEA

.-DE

C*H

60*P

RTL

X46

646

110

3+

DE

CA

L-C

AU

TIO

N-C

AB

LEC

RE

AS

ING

0446

142

000

+P

LATE

-BA

CK

UP

-ME

MB

RA

NE

SW

ITC

H04

4578

210

3P

LUG

-Q.D

.CO

21/

8M

P02

1077

310

3S

YR

UP

LIN

ES

ModelH60

Page 54: 0 h60 manual

+ Available Separately

50Parts List Model H60

051103

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

H60

QTY.

PART

NUMBER

PLU

G-Q

.D.L

IQ.3

/4-1

8FP

0210

813

103

SY

RU

PLI

NE

S+

O-R

ING

-5/8

OD

X.1

03W

0160

303

000

SY

RU

PLI

NE

SP

RO

BE

A.-M

IXLO

W-H

TX

4207

71

103

+D

ISC

-PR

OB

E*S

QH

OLE

*03

0965

110

3+

SP

AC

ER

-PR

OB

E*S

QH

OLE

*03

0966

110

3P

RO

BE

A.-M

IXO

UT-

SQ

UA

RE

HO

LEX

4134

81

103

+O

-RIN

G-1

/2O

DX

.070

W02

4278

200

0+

SP

AC

ER

-PR

OB

E-R

OU

ND

HO

LE-5

/8D

IA04

1347

110

3+

SP

AC

ER

-PR

OB

E-S

QU

AR

EH

OLE

-7/8

0413

461

103

PR

OB

E-T

HE

RM

ISTO

R-B

AR

RE

L-2%

TOL

0380

61-B

LK1

103

BA

RR

EL

PR

OB

E-T

HE

RM

ISTO

R-H

OP

PE

R-2

%TO

L03

9470

-BLK

210

3H

OP

PE

R&

HE

ATE

RP

ULL

EY

-AG

TD

R-1

.910

PD

X5/

16TH

D03

6210

110

360

Hz

ON

LY+

SC

RE

W-8

-32

X1/

4A

LLE

NS

ET

0436

031

000

PU

LLE

Y-A

GT

MTR

-1.9

10P

DX

3/8B

OR

E04

2063

110

3+

SC

RE

W-8

-32

X1/

4A

LLE

NS

ET

0436

032

000

PU

LLE

Y-A

K25

-5/8

0191

531

103

MO

TOR

-60H

zO

NLY

PU

LLE

Y-A

K64

-5/8

0075

381

103

GE

AR

PU

MP

-GLY

CO

L-1/

8NP

T-16

50R

PM

0417

851

112

+M

OTO

R-S

ER

VIC

E-G

LYC

OL

PU

MP

0417

85-1

111

2+

PU

MP

-SE

RV

ICE

-GLY

CO

LP

UM

P04

1785

-21

112

+B

OO

T-G

LYC

OL

PU

MP

0421

311

000

RE

LAY

-3P

OLE

-20A

-208

/240

50/6

001

2725

-33

110

3R

ELA

Y-S

PD

T-30

A-2

40V

0326

07-2

71

103

HE

ATE

RR

ELA

Y-D

PD

T-20

A-1

20/2

40/2

77V

0265

81-2

71

103

K01

1766

0/U

PS

PIN

NE

R15

3R

ELA

Y-S

PIN

NE

RM

OTO

R-1

/2H

P-2

30V

0160

06-2

71

103

K01

1765

9/P

RIO

RR

ES

TRIC

TOR

-SY

RU

P45

2B

LAC

K03

0917

200

0S

AN

ITIZ

ER

KA

Y-5

0410

821

000

CA

SE

OF

125

PA

CK

ETS

SA

NIT

IZE

R-S

TER

AS

HE

EN

-GR

EE

N05

5492

100

0C

AS

EO

F10

0/2O

ZP

AC

KE

TS12

/1/0

0/U

PS

HA

FT-B

EA

TER

0355

271

103

+S

EA

L-D

RIV

ES

HA

FT03

2560

100

0S

HA

FT-D

RIV

E-F

LEX

IBLE

0167

871

103

NE

WD

ES

IGN

-PR

ELU

BE

D82

ModelH60

Page 55: 0 h60 manual

51

+ Available Separately

Model H60 Parts List

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

H60

QTY.

PART

NUMBER

+S

CR

EW

-8-3

2X

3/16

ALL

EN

SE

T00

6812

200

0+

SH

AFT

-EX

TEN

SIO

N*4

52-4

53*

0346

931

103

SH

ELL

A.-I

NS

ULA

TED

*H60

*HO

OD

X46

622

151

2+

STU

D-N

OS

EC

ON

E5/

16-1

8X3/

8-16

0113

904

103

SH

IELD

-MIX

-GE

AR

RE

DU

CE

R3-

3/8”

0133

561

103

SH

IELD

-SP

LAS

H-W

IRE

13-1

1/16

L04

6177

110

3S

HR

OU

D-C

ON

DE

NS

ER

*SH

-HT-

GE

N3

0417

281

103

SH

RO

UD

-LE

FT*5

472

HT*

0420

831

103

SH

RO

UD

-RIG

HT

*547

2H

T*04

2084

110

3S

PR

ING

-TO

RQ

UE

*BLA

CK

*01

5007

110

3S

TAR

TER

-BE

ATE

RLI

NE

0419

50-

110

3O

VE

RLO

AD

-TH

ER

MA

L04

7150

-1

103

SW

ITC

HA

.-TO

RQ

UE

*H60

*X

4665

61

103

HU

BA

.-AR

MX

1703

31

103

SW

ITC

H-S

NA

P-S

PD

T-20

A/1

25-2

50V

0144

721

103

SW

ITC

HA

.-DR

AW

*H60

*X

5479

11

K10

1358

5R

EP

LAC

ES

X41

374

AR

MA

.-DR

AW

*H60

*X

5479

21

BR

AC

KE

T-D

RA

WA

RM

*452

HT*

0435

261

E-R

ING

3/16

.335

O.D

.04

9178

1P

IN-P

IVO

T01

5478

1P

LATE

-DR

AW

SW

ITC

H*4

52H

T*04

3527

1S

CR

EW

-10-

32X

9/16

DO

GP

TS

ET

0389

811

SC

RE

W-4

-40

X5/

8R

HM

-ZP

STE

E02

7219

2S

WIT

CH

-LE

VE

R-S

PD

T-11

A-1

25-2

703

9252

1S

WIT

CH

A.-D

RA

W*4

52H

T*G

EN

3X

4137

41

103

PR

IOR

TOK

1013

585

RE

PLA

CE

DB

YX

5479

1A

RM

A.-D

RA

W*4

52*H

T*X

4352

41

103

BR

AC

KE

T-D

RA

WA

RM

*452

HT*

0435

261

103

E-R

ING

3/16

.335

O.D

.04

9178

100

0P

IN-P

IVO

T01

5478

110

3P

LATE

-DR

AW

SW

ITC

H*4

52H

T*04

3527

110

3

ModelH60

Page 56: 0 h60 manual

+ Available Separately

52Parts List Model H60

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

H60

QTY.

PART

NUMBER

SC

RE

W-1

0-32

X9/

16D

OG

PT

SE

T03

8981

110

3S

CR

EW

-4-4

0X

5/8

RH

M-Z

PS

TEE

L02

7219

110

3S

WIT

CH

-LE

VE

R-S

PD

T-11

A-1

25-2

50V

0392

521

103

SW

ITC

H-M

EM

BR

AN

E-5

PO

SIT

ION

-20”

L04

4521

110

3K

EY

PA

DS

WIT

CH

-ME

MB

RA

NE

-5P

OS

ITIO

N-8

”L04

4520

110

3K

EY

PA

DS

WIT

CH

-PR

ES

SU

RE

440P

SI-

SO

LDE

R04

8230

110

3J4

0663

683/

UP

105

SW

ITC

H-P

RE

SS

UR

E25

PS

OP

EN

405

0308

861

103

J406

6368

2/P

RIO

R83

SW

ITC

H-T

OG

GLE

-DP

DT*

ON

-NO

NE

-ON

0242

951

103

PO

WE

RTA

NK

-SY

R-4

QT

0455

333

103

CO

MP

LETE

W/C

OV

ER

&IN

TER

NA

LP

AR

TSIN

CLU

DE

S:

CO

VE

R-T

AN

KW

/FIT

TIN

G03

5759

-13

103

DE

CA

L-S

YR

UP

TAN

KIN

STR

UC

TIO

N04

5533

-13

000

TIP

-NY

LON

-WH

ITE

0427

47*

600

0*D

UA

LS

UP

PLI

ER

-OR

DE

RA

SN

EE

DE

DTI

P-N

YLO

N-G

RE

Y02

4261

*6

000

*D

UA

LS

UP

PLI

ER

-OR

DE

RA

SN

EE

DE

DG

AS

KE

T01

6037

300

0FO

RC

OV

ER

TUB

E-D

IP01

5441

-73

103

O-R

ING

0185

503

000

FOR

DIP

TUB

ETA

NK

-GLY

CO

L(P

LAS

TIC

)04

7314

110

3J4

0200

00/U

P79

CA

P-G

LYC

OL

TAN

K04

7314

-11

103

TEE

-5/1

6B

AR

BB

RA

SS

0473

241

000

J402

0000

/UP

79TE

E-A

CC

ES

S04

7587

100

0J4

0200

00/U

P79

TOR

QU

EA

.*45

2-45

3*X

1738

11

103

+O

-RIN

G-.2

91ID

X.0

80W

0185

502

000

TRA

NS

.-CO

NT.

-40V

A12

0/20

0/24

0V04

5754

110

3TR

AN

S.-C

ON

T.-A

NTI

CIP

ATO

R20

VA

0163

52-

110

3TR

AY

-DR

IP14

.804

6275

110

3TR

IM-R

EA

RC

OR

NE

R*H

60*

0466

682

103

TUB

EA

.-FE

ED

-OU

TER

-HT

X34

641

110

3+

O-R

ING

-.643

OD

X.0

77W

0185

722

000

TUB

EA

.-FE

ED

-SC

-INN

ER

-1/4

HX

3282

4-5

110

3S

TAR

TA

T03

/12/

9591

ModelH60

Page 57: 0 h60 manual

53

+ Available Separately

Model H60 Parts List

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

H60

QTY.

PART

NUMBER

+O

-RIN

G-.2

91ID

X.0

80W

0185

503

000

VA

LVE

-AC

CE

SS

1/4F

LX

3/8S

DR

-90

0444

551

103

J406

3682

/PR

IOR

VA

LVE

-AC

CE

SS

1/4

MFL

X1/

4S-9

004

7016

110

3J4

0636

83/U

PV

ALV

E-A

CC

ES

S1/

4FLX

5/16

SD

R-9

0530

271

103

US

EW

ITH

0475

20-*

*FFR

EN

CH

CO

MP

RE

SS

OR

VA

LVE

A.-S

OLE

NO

ID-3

FLV

*H60

*X

4663

9-03

110

3S

YR

UP

-3FL

AV

OR

BR

AC

KE

T-S

OLE

NO

ID*H

60*

0466

401

103

ELB

OW

-1/4

MP

X1/

4BA

RB

-PLA

STI

C01

6614

310

3E

LBO

W-1

/4M

PX

3/16

BA

RB

-PLA

STI

C01

6615

310

3FE

RR

ULE

-.475

IDN

PB

RA

SS

0210

823

000

LAB

EL-

1/4

X1-

1/2

LON

G-B

RO

WN

0227

101

000

LAB

EL-

1/4

X1-

1/2

LON

G-D

KB

LUE

0227

081

000

LAB

EL-

1/4

X1-

1/2

LON

G-R

ED

0227

071

000

TUB

E-N

YLO

BR

AD

E1/

4ID

X7/

16O

D02

0568

-44

300

0B

ULK

-100

FTR

3031

7TU

BE

-VIN

YL

3/16

IDX

1/16

WA

LL02

0940

-15

300

0B

ULK

-100

FTR

3031

4V

ALV

E-S

OLE

NO

ID-3

/16”

OR

IFIC

E-S

S04

1589

-03

310

3TO

OL

FOR

SO

LEN

OID

VA

LVE

-046

303

VA

LVE

A.-S

OLE

NO

ID-R

INS

E*H

60*

X46

657-

271

103

RIN

SE

TUB

E-V

INY

L3/

16ID

X1/

16W

ALL

0209

40-1

11

000

BU

LK-1

00FT

R30

314

VA

LVE

-SO

LEN

OID

-3/3

2”O

RIF

ICE

-SS

0415

99-2

71

103

TOO

LFO

RS

OLE

NO

IDV

ALV

E-0

4630

3V

ALV

E-E

XP

-AU

TO-1

/4S

X1/

4FP

T04

6365

110

3B

OO

T-E

XP

AN

SIO

NV

ALV

E05

0900

100

0V

ALV

E-S

OLE

NO

ID04

4125

-1

103

AC

CU

MU

LATO

RV

IDE

O-T

RA

INH

6004

9894

-V1

000

WA

SH

ER

-PLA

STI

CP

IVO

T01

3808

200

0S

YR

UP

LIN

ES

WA

TER

CO

OLE

DB

LOW

ER

-100

CFM

0127

96-

110

3B

RA

CK

ET-

MO

UN

TIN

G-W

ATE

RV

ALV

E03

8777

100

0W

ATE

RV

ALV

ES

CR

EW

-8-3

2X

5/16

PH

PA

NH

D03

8778

200

0W

ATE

RV

ALV

EC

ON

DE

NS

ER

-W/C

0475

401

103

GU

AR

D-B

LOW

ER

0225

051

103

ModelH60

Page 58: 0 h60 manual

+ Available Separately

54Parts List Model H60

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

H60

QTY.

PART

NUMBER

HO

SE

-RU

BB

ER

1/2”

X7/

8R

5020

04.

5ft

000

RE

CE

IVE

RA

.-RE

FRIG

ER

AN

TX

4810

71

103

SW

ITC

H-P

RE

SS

UR

E35

0P

SI

0482

311

103

J604

0000

/UP

105

SW

ITC

H-P

RE

SS

UR

E35

0P

SI

0464

311

103

J603

9999

/PR

IOR

105

VA

LVE

-WA

TER

3/8

RE

G/H

EA

D04

6686

110

3

50H

zB

ELT

0070

981

000

BLO

CK

-TE

RM

INA

L-3

PO

LE03

9424

110

322

0-24

0/38

0-41

5V-5

0-3

CA

PA

CIT

OR

-RU

N01

2906

110

3J4

0636

82/P

RIO

R(B

RIS

TOL)

CA

PA

CIT

OR

-RU

N02

9439

110

3J4

0636

83/U

P(T

EC

UM

SE

H)

CA

PA

CIT

OR

-RU

N(M

AG

NE

TEK

)03

3050

110

3B

EA

TER

MO

TOR

CA

PA

CIT

OR

-RU

N(L

EE

SO

N)

0360

841

103

BE

ATE

RM

OTO

RC

AP

AC

ITO

R-S

TAR

T03

8143

110

3J4

0636

82/P

RIO

R(B

RIS

TOL)

CA

PA

CIT

OR

-STA

RT

0481

341

103

J406

3683

/UP

(TE

CU

MS

EH

)C

AP

AC

ITO

R-S

TAR

T(M

AG

NE

TEK

)03

3043

110

3B

EA

TER

MO

TOR

CA

PA

CIT

OR

-STA

RT

(LE

ES

ON

)03

5798

110

3B

EA

TER

MO

TOR

MO

TOR

-FA

N10

0WA

TT04

7178

-34

110

3P

ULL

EY

-AG

ITA

TOR

MO

TOR

0457

181

103

PU

LLE

Y-A

GIT

ATO

RD

RIV

E04

5717

110

3P

ULL

EY

-AK

30x

5/8

(MO

TOR

)03

3559

110

3B

EA

TER

MO

TOR

RE

LAY

-STA

RT

CO

MP

RE

SS

OR

0381

461

103

J406

3682

/PR

IOR

(BR

ISTO

L)R

ELA

Y-S

TAR

TC

OM

PR

ES

SO

R04

8133

110

3J4

0636

83/U

P(T

EC

UM

SE

H)

VID

EO

-TR

AIN

H60

0498

94-P

AL

100

0

ModelH60

Page 59: 0 h60 manual

Model H60046638--27Rev. 8/11

Page 60: 0 h60 manual

Model H60046638--33Rev. 8/11

Page 61: 0 h60 manual

Model H60046638--34Rev. 8/11

Page 62: 0 h60 manual

Model H60046638--35Rev. 8/11