Elite Telephone Entry Door Intercom

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

(T

Operating Voltage - Keypad: 12vDC 100mA

Operating Voltage - Communication: 12vDC 60mA

Operating Voltage - IP Camera: POE 802.3af or 12vDC 500mA

Cable Requirements - IP Camera: 1 CAT5/6 with POE for camera

Cable Requirements- Communication: 1 18/2 power wire for amplified companion

board, button & keypad

2 Conductor CAT5/6 for companion board

(communication)

ypical at 77º)

Page 2: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

Channel Vision’s SIK-Series door stations can interface with a variety of telephone entry control products to provide communication with the front door. They are available in a variety of configurations including options for an IP or 960H analog camera and compatibility with Panasonic’s popular KSU phone systems. A contact closure is provided for connection to a door strike relay or door strike.

Dimensions: Plate

6.70”

9.70”

8.350” 8.79”

5.84”

0.25”PlateDepthOnly

Dimensions: SIK-Rbox (not included)

Features:h

hIP or 960H analog camerah

h

h

h

Rust-resistant faceplateDiscrete speaker and microphone

Flush or surface mount optionsAvailable in many different finishesLit button

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

Understanding the model number:

Understanding the compatibility options

Part numbering: SIK door plates

There are three different types of systems that SIK door stations can be used with. The compatibility for these different types of systems is indicated by the suffix of the model number which follows the 4-digit numerical code.

If the suffix is the letter “A”, such as SIK-6212A, that door station is compatible with Channel Vision’s telephone entry products including models P-0920 & P-0921.

If the suffix is the letter “C”, such as SIK-7212C, then the door plate is compatible with Channel Vision’s Whole-House CAT5 Intercom Hub, model P-0930.

If the suffix is the letter “P”, such as SIK-7212P, then the door plate is compatible with Panasonic KSUs.

Please double check to be sure that you have purchased the correct model number for your application. 2 3

SIK 7 252 A-WN

Analog CameraMegapixel IP Camera

Wiegand 26 Bit Nickel KeypadWiegand 26 Bit Black KeypadSingle Door Black KeypadSingle Door Nickel Keypad

SIK Elite Series Faceplate

67

SIK

A

Part Number Example:

Oil Rubbed BronzeBlackSatin Nickel

White** Polished Brass** Antique Brass**

252282302

212222232

P

C

I

SK

Compatible with Panasonic KSU’s

P0930 CAT5 Controller

IP Camera with 2 Way Communication Door Station

Intercom Door Station with SIP Kit

[ [ [ [ [

WNWBSBSN

Page 3: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

Channel Vision’s SIK-Series door stations can interface with a variety of telephone entry control products to provide communication with the front door. They are available in a variety of configurations including options for an IP or 960H analog camera and compatibility with Panasonic’s popular KSU phone systems. A contact closure is provided for connection to a door strike relay or door strike.

Dimensions: Plate

6.70”

9.70”

8.350” 8.79”

5.84”

0.25”PlateDepthOnly

Dimensions: SIK-Rbox (not included)

Features:h

hIP or 960H analog camerah

h

h

h

Rust-resistant faceplateDiscrete speaker and microphone

Flush or surface mount optionsAvailable in many different finishesLit button

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

Understanding the model number:

Understanding the compatibility options

Part numbering: SIK door plates

There are three different types of systems that SIK door stations can be used with. The compatibility for these different types of systems is indicated by the suffix of the model number which follows the 4-digit numerical code.

If the suffix is the letter “A”, such as SIK-6212A, that door station is compatible with Channel Vision’s telephone entry products including models P-0920 & P-0921.

If the suffix is the letter “C”, such as SIK-7212C, then the door plate is compatible with Channel Vision’s Whole-House CAT5 Intercom Hub, model P-0930.

If the suffix is the letter “P”, such as SIK-7212P, then the door plate is compatible with Panasonic KSUs.

Please double check to be sure that you have purchased the correct model number for your application. 2 3

SIK 7 252 A-WN

Analog CameraMegapixel IP Camera

Wiegand 26 Bit Nickel KeypadWiegand 26 Bit Black KeypadSingle Door Black KeypadSingle Door Nickel Keypad

SIK Elite Series Faceplate

67

SIK

A

Part Number Example:

Oil Rubbed BronzeBlackSatin Nickel

White** Polished Brass** Antique Brass**

252282302

212222232

P

C

I

SK

Compatible with Panasonic KSU’s

P0930 CAT5 Controller

IP Camera with 2 Way Communication Door Station

Intercom Door Station with SIP Kit

[ [ [ [ [WNWBSBSN

Page 4: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

The SIK SIK both interface with the Channel Visiontelephone entry controllers, P-0920 and P-0921 to provide audio and video communication with the front door. Using a 2-conductor wire, connect the Telephone Entry Controller to the empty screw terminal block on the door station (see diagram). For the camera, use CAT5 (POE for power) or a coax for analog video and 18/2 wire

-6xxxA-xx and -7xxxA-xx ’s

Channel Vision Compatible (SIK-xxxxA-xx)

Panasonic (SIK-xxxxP-xx) Compatible

StrikeActive

Ring

IntercomActive

12VAC

#o

r* N

o C

O

StrikeTime3

/5 r

ng 1 2 3

PowerIntercomUnlock Door

ChimeCO Input Phones

TELEPHONE ENTRY CONTROLLER

CO Input Telephones

Model P-0920 PROCHANNEL

TMV ISION

From Telephone Service Provider

HouseTelephones

12VAC 500mA

Using a 2-conductor wire, connect the door phone output of your Panasonic KSU to the empty screw terminal block on the door station

Channel Vision's Panasonic models are a compatible replacement for the Panasonic KXT30865. They are an attractive alternative to the standard plastic door station sold by Panasonic. This product interfaces with Panasonic’s KSU phone systems to provide communication with the front door.

Connect to the terminals marked

“TO SYS”From Telephone Service Provider

System Phones

Panasonic

KSU

4 5

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

ST-C5IDS

S G P

500ft.max

The diagram below shows how to connect the SIK-xxxxC-xx to Channel Vision’s CAT5 Whole-House Intercom system. When the button is pressed on the SIK-xxxxC-xx the ST-3000 Intercom Stations will generate a door chime. Pressing Answer/End will open communication with the SIK-xxxxC-xx. Model SIK-6xxxC-xx includes an analog 960H color camera and SIK-7xxxC-xx includes an IP camera.

Channel Vision Compatible ( -xxxx )

CAT5 Intercom SIK C-xx

P-0930

PROCHANNEL TMV ISION

Model P-0930

Whole-House Intercom

Page Out

Page Trigger

IR

Emitters +15VDC

Power

LinkIn

Link Out

Hub

A

B

C

D Room 1 Room 2 Room 3 Room 4 Room 5 Room 6

ST-3000Press here to answer door

Using CAT5 wire, connect the P-0930 to the 110 connector on the door station

SIK-xxxxC

SIK-7xxxA

SIK-7xxxP

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

Using the Access Keypad

Power Light: (Green)IMPORTANT: if power light does not illuminate, immediately disconnect power supply and check for correct polarity.

Status Light: (Red)

Keypad

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

Page 5: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

The SIK SIK both interface with the Channel Visiontelephone entry controllers, P-0920 and P-0921 to provide audio and video communication with the front door. Using a 2-conductor wire, connect the Telephone Entry Controller to the empty screw terminal block on the door station (see diagram). For the camera, use CAT5 (POE for power) or a coax for analog video and 18/2 wire

-6xxxA-xx and -7xxxA-xx ’s

Channel Vision Compatible (SIK-xxxxA-xx)

Panasonic (SIK-xxxxP-xx) Compatible

StrikeActive

Ring

IntercomActive

12VAC

#o

r* N

o C

O

StrikeTime3

/5 r

ng 1 2 3

PowerIntercomUnlock Door

ChimeCO Input Phones

TELEPHONE ENTRY CONTROLLER

CO Input Telephones

Model P-0920 PROCHANNEL

TMV ISION

From Telephone Service Provider

HouseTelephones

12VAC 500mA

Using a 2-conductor wire, connect the door phone output of your Panasonic KSU to the empty screw terminal block on the door station

Channel Vision's Panasonic models are a compatible replacement for the Panasonic KXT30865. They are an attractive alternative to the standard plastic door station sold by Panasonic. This product interfaces with Panasonic’s KSU phone systems to provide communication with the front door.

Connect to the terminals marked

“TO SYS”From Telephone Service Provider

System Phones

Panasonic

KSU

4 5

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

ST-C5IDS

S G P

500ft.max

The diagram below shows how to connect the SIK-xxxxC-xx to Channel Vision’s CAT5 Whole-House Intercom system. When the button is pressed on the SIK-xxxxC-xx the ST-3000 Intercom Stations will generate a door chime. Pressing Answer/End will open communication with the SIK-xxxxC-xx. Model SIK-6xxxC-xx includes an analog 960H color camera and SIK-7xxxC-xx includes an IP camera.

Channel Vision Compatible ( -xxxx )

CAT5 Intercom SIK C-xx

P-0930

PROCHANNEL TMV ISION

Model P-0930

Whole-House Intercom

Page Out

Page Trigger

IR

Emitters +15VDC

Power

LinkIn

Link Out

Hub

A

B

C

D Room 1 Room 2 Room 3 Room 4 Room 5 Room 6

ST-3000Press here to answer door

Using CAT5 wire, connect the P-0930 to the 110 connector on the door station

SIK-xxxxC

SIK-7xxxA

SIK-7xxxP

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

Using the Access Keypad

Power Light: (Green)IMPORTANT: if power light does not illuminate, immediately disconnect power supply and check for correct polarity.

Status Light: (Red)

Keypad

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

Page 6: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

SIK Series Keypad ProgrammingThe SIK Series Keypad is an easy to program, easy to use, stand alone, self-contained entry system with features suitable for basic access control requirements. Providing either a voltage output or dry contact closure, the SIK Series Keypad is designed to control any fail-safe or fail-secure electric locking device. One relay output is available to provide a variety of access control configurations including single door access control, Gate/Garage Door control.

Overview of System Code ProgrammingThere are two levels of codes for the SIK Series Keypad.1. The Master Code: Used by the owner to program User Codes.2. User Codes: Used by guests/personnel to open the door.

Important Notes:1. The Keypad has two digits on each pad. The system reads these numbers as the same. For example: “1-3-5-7-9” is the same as “2-4-6-8-0”.2. All codes must be 3 to 8 digits.3. All codes must be different from each other.4. Do not program codes, which are part of other codes.Example: User Code 1: “1-2-3-4” and User Code 2: “1-2-3”5. During programming, the system resets after 5 seconds if a number is not entered. Do not let more than 5 seconds elapse between entries or the system will reset and you will have to start over.

Overview of the Master Code:Knowledge of the Master Code is the highest priviledge granted to a user of the SIK Series Keypad system. There is only one master code, which is used to program each of the 5 User Codes. The factory default Master Code, “1-3-5-7-9”, can be used for initial programming but should be changed to a unique code.Note: The Master Code does not have the ability to Latch.

Programming or changing the Master Code:1. Select a 3 to 8 digit code that will be used for the Master Code.2. Enter the old Master Code (default is “1-3-5-7-9”) followed by the symbol on the keypad. (The Keypad will beep rapidly 4 times*) Proceed to step 5.3. If you do not know the Master Code, locate the PINK Program wire on the harness. (As an alternative, you can momentarily short the two “PGM” pins on the back of the Keypad. This will take you to step 5)4. Touch the PINK Program wire to the BLACK wire for one second (The Keypad will beep rapidly 4 times)*5. At the Keypad, enter “1-1-1-9” to open the memory (you will hear three rapid beeps) and immediately enter your new Master code.(Do NOT let more than five seconds elapse between entries or the system will reset and you will have to start over.)6. After entering your new Master Code, wait five seconds for the 3 reset beeps.* Once in Programming Mode, you have 2 minutes to begin programming. After 2 minutes, the system resets to Normal operation.

76

3. If you do not know the Master Code, locate the PINK Program wire on the harness. (As an alternative, you can momentarily short the two “PGM” pins on the back of the Keypad. This will take you to step 5)4. Touch the PINK Program wire to the BLACK wire for one second (The Keypad will beep rapidly 4 times)*5. At the Keypad, enter “1-1-1-7” to open the memory (you will hear three rapid beeps) and enter a combination of “5’s” (for every five second increment) and “1’s” (for every one second increment) that equal your desired Door Open Time. Each valid key press (a “1” or a “5”) will generate a double beep.Example: “1-1-1-7 5-5-5-1-1” 17 seconds6. After entering your Door Open Time, wait five seconds for the 3 reset beeps.Notes: * Once in Programming Mode, you have 2 minutes to begin programming. You will hear a double beep with each valid key press. Once you begin entering the combination of 1’s and 5’s do not let more than five seconds elapse between entries or the system will reset. Maximum Door Open Time is 120 seconds.

Overview of User Codes:There are a total of 5 User codes that can be programmed into the SIK Series Keypad. User Codes can vary in length from 3 to 8 digits. Each User Code is programmed into one of 5 User Locations. These Locations are as follows:

User # User LocationUser Code 1 1-1-1User Code 2 1-1-3User Code 3 1-1-5User Code 4 1-1-7User Code 5 1-1-9Once a User Code has been programmed into a User Location, the User Code can be easily changed or deleted from the system

Programming User Codes:To Program a New User Code/Change an Existing User Code:1. Choose a new 3 to 8 digit code that will be used for this User Code. 2. Decide which User Location to place this User Code 3. Enter the Master Code, followed by the User Location (you will hear three rapid beeps) and immediately enter the new User Code. (Do not let more than five seconds elapse between entries or the system will reset)Example: “1-3-5-7-9 1-1-1 1-3-3-5”This programs the code 1-3-3-5 into User Location #1.4. After entering your new code, wait five seconds for the 3 reset beeps.

To Delete a User Code:1. Enter the Master Code, followed by the User Location of the User Code you want to delete (you will hear three beeps).Example: “1-3-5-7-9 1-1-5” This deletes the User Location #3 programmed code.

SIK Series Keypad Programming Cont.

Page 7: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

SIK Series Keypad ProgrammingThe SIK Series Keypad is an easy to program, easy to use, stand alone, self-contained entry system with features suitable for basic access control requirements. Providing either a voltage output or dry contact closure, the SIK Series Keypad is designed to control any fail-safe or fail-secure electric locking device. One relay output is available to provide a variety of access control configurations including single door access control, Gate/Garage Door control.

Overview of System Code ProgrammingThere are two levels of codes for the SIK Series Keypad.1. The Master Code: Used by the owner to program User Codes.2. User Codes: Used by guests/personnel to open the door.

Important Notes:1. The Keypad has two digits on each pad. The system reads these numbers as the same. For example: “1-3-5-7-9” is the same as “2-4-6-8-0”.2. All codes must be 3 to 8 digits.3. All codes must be different from each other.4. Do not program codes, which are part of other codes.Example: User Code 1: “1-2-3-4” and User Code 2: “1-2-3”5. During programming, the system resets after 5 seconds if a number is not entered. Do not let more than 5 seconds elapse between entries or the system will reset and you will have to start over.

Overview of the Master Code:Knowledge of the Master Code is the highest priviledge granted to a user of the SIK Series Keypad system. There is only one master code, which is used to program each of the 5 User Codes. The factory default Master Code, “1-3-5-7-9”, can be used for initial programming but should be changed to a unique code.Note: The Master Code does not have the ability to Latch.

Programming or changing the Master Code:1. Select a 3 to 8 digit code that will be used for the Master Code.2. Enter the old Master Code (default is “1-3-5-7-9”) followed by the symbol on the keypad. (The Keypad will beep rapidly 4 times*) Proceed to step 5.3. If you do not know the Master Code, locate the PINK Program wire on the harness. (As an alternative, you can momentarily short the two “PGM” pins on the back of the Keypad. This will take you to step 5)4. Touch the PINK Program wire to the BLACK wire for one second (The Keypad will beep rapidly 4 times)*5. At the Keypad, enter “1-1-1-9” to open the memory (you will hear three rapid beeps) and immediately enter your new Master code.(Do NOT let more than five seconds elapse between entries or the system will reset and you will have to start over.)6. After entering your new Master Code, wait five seconds for the 3 reset beeps.* Once in Programming Mode, you have 2 minutes to begin programming. After 2 minutes, the system resets to Normal operation.

76

3. If you do not know the Master Code, locate the PINK Program wire on the harness. (As an alternative, you can momentarily short the two “PGM” pins on the back of the Keypad. This will take you to step 5)4. Touch the PINK Program wire to the BLACK wire for one second (The Keypad will beep rapidly 4 times)*5. At the Keypad, enter “1-1-1-7” to open the memory (you will hear three rapid beeps) and enter a combination of “5’s” (for every five second increment) and “1’s” (for every one second increment) that equal your desired Door Open Time. Each valid key press (a “1” or a “5”) will generate a double beep.Example: “1-1-1-7 5-5-5-1-1” 17 seconds6. After entering your Door Open Time, wait five seconds for the 3 reset beeps.Notes: * Once in Programming Mode, you have 2 minutes to begin programming. You will hear a double beep with each valid key press. Once you begin entering the combination of 1’s and 5’s do not let more than five seconds elapse between entries or the system will reset. Maximum Door Open Time is 120 seconds.

Overview of User Codes:There are a total of 5 User codes that can be programmed into the SIK Series Keypad. User Codes can vary in length from 3 to 8 digits. Each User Code is programmed into one of 5 User Locations. These Locations are as follows:

User # User LocationUser Code 1 1-1-1User Code 2 1-1-3User Code 3 1-1-5User Code 4 1-1-7User Code 5 1-1-9Once a User Code has been programmed into a User Location, the User Code can be easily changed or deleted from the system

Programming User Codes:To Program a New User Code/Change an Existing User Code:1. Choose a new 3 to 8 digit code that will be used for this User Code. 2. Decide which User Location to place this User Code 3. Enter the Master Code, followed by the User Location (you will hear three rapid beeps) and immediately enter the new User Code. (Do not let more than five seconds elapse between entries or the system will reset)Example: “1-3-5-7-9 1-1-1 1-3-3-5”This programs the code 1-3-3-5 into User Location #1.4. After entering your new code, wait five seconds for the 3 reset beeps.

To Delete a User Code:1. Enter the Master Code, followed by the User Location of the User Code you want to delete (you will hear three beeps).Example: “1-3-5-7-9 1-1-5” This deletes the User Location #3 programmed code.

SIK Series Keypad Programming Cont.

Page 8: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

ConnectionsConnecting the Locking Device:Connect the electric locking device to the wire harness as outlined in the Typical System Wiring and Typical Output Wiring.Any 2 conductor, 22 gauge wire can be used to connect the Keypad to the Locking Device. Included in the spare parts kit is a MOV (Metal Oxide Varistor). The function of the MOV is to absorb any inductive kickback from the locking device, protecting the Keypad circuit board. Install the MOV as close to the electric lock as possible.To provide proper grounding, connect a 3rd wire from the body of the locking device to Earth ground. IMPORTANT: If switching voltages higher than 24V, you must use an external relay. The keypad’s built-in relay is capable of switching up to 24V.Damage caused by connecting a higher voltage is not covered under

Programming Door Open Time:The system default is 5 seconds1. First, determine the length of time you wish to program as the Door Open Time. This is the length of time the door will remain open after a valid Code has been entered.Note: For controlling a garage door or electric gate, you will need to set the door open time to 1 second and remove the “DC +” Jumper on back of keypad.2. Enter the Master Code (default is “1-3-5-7-9”) followed by the symbol on the keypad. (The Keypad will beep rapidly 4 times*). Proceed to step 5.3. If you do NOT know the Master Code, locate the PINK Program wire on the harness. (As an alternative, you can momentarily short the two “PGM” pins on the back of the Keypad. This will take you to step 5)4. Touch the PINK Program wire to the BLACK wire for one second (The Keypad will beep rapidly 4 times)*5. At the Keypad, enter 1-1-1-7 to open the memory (you will hear three rapid beeps) and enter a combination of “5’s” (for every five second increment) and “1’s” (for every one second increment) that equal your desired Door Open Time. Each valid key press (a “1” or a “5”) will generate a double beep.Example: “1-1-1-7 5-5-5-1-1” .. 17 seconds6. After entering your Door Open Time, wait five seconds for the 3 reset beeps... Notes: * Once in Programming Mode, you have 2 minutes to begin programming. You will hear a double beep with each valid key press. Once you begin entering the combination of 1’s and 5’s do not let more than five seconds elapse between entries or the system will reset. Maximum Door Open Time is 120 seconds.

SIK Series Keypad Programming Cont.

8 9

Hardware Setup ContinuedKeypad Illumination:Designed for areas will low ambient lighting, the SIK Series Keypad provides nighttime illumination. Keypad illumination is on by default. This option can be turned OFF by cutting the BLUE Illumwire loop on the back of the Keypad.

Setting Output Options:The SIK Series Keypad provides options for configuring the relay output as well as the grounding outputs. These options include Voltage vs. Dry Contact Output and Latching Authorization for the main output.

Input Requirements:Voltage: 12 to 24 volts AC/DC. System current draw (maximum):Standby: 10mA at 12/24 voltsDuring Operation: .10 amps max

IMPORTANT: The maximum output current allowed is ½ amp. Check the specifications of your locking device. Verify the locking device draws less than ½ amp. For locking devices that draw more current, a separate power supply is required. Note: If connecting DC, make the connections to the Red and Black wires instead of the Gray and White wires. Verify the polarity is correct.

Output Capabilities:The SIK Series Keypad provides one SPDT dry contact relay (rated at 2 amps at 24 VAC). The relay can be configured for one of the following options:Voltage Output: Fail Safe or Fail Secure Locking DeviceDry Contact Output: Control a Gate Operator/Garage DoorTwo auxiliary ¼ Amp grounding outputs are available to drive external relays. These can be configured for CCTV/Light Controller or other device.(First key press triggers a 10 second output)Doorbell or other device: Press the symbol to trigger a 1 second output.

Input & Output

Page 9: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

ConnectionsConnecting the Locking Device:Connect the electric locking device to the wire harness as outlined in the Typical System Wiring and Typical Output Wiring.Any 2 conductor, 22 gauge wire can be used to connect the Keypad to the Locking Device. Included in the spare parts kit is a MOV (Metal Oxide Varistor). The function of the MOV is to absorb any inductive kickback from the locking device, protecting the Keypad circuit board. Install the MOV as close to the electric lock as possible.To provide proper grounding, connect a 3rd wire from the body of the locking device to Earth ground. IMPORTANT: If switching voltages higher than 24V, you must use an external relay. The keypad’s built-in relay is capable of switching up to 24V.Damage caused by connecting a higher voltage is not covered under

Programming Door Open Time:The system default is 5 seconds1. First, determine the length of time you wish to program as the Door Open Time. This is the length of time the door will remain open after a valid Code has been entered.Note: For controlling a garage door or electric gate, you will need to set the door open time to 1 second and remove the “DC +” Jumper on back of keypad.2. Enter the Master Code (default is “1-3-5-7-9”) followed by the symbol on the keypad. (The Keypad will beep rapidly 4 times*). Proceed to step 5.3. If you do NOT know the Master Code, locate the PINK Program wire on the harness. (As an alternative, you can momentarily short the two “PGM” pins on the back of the Keypad. This will take you to step 5)4. Touch the PINK Program wire to the BLACK wire for one second (The Keypad will beep rapidly 4 times)*5. At the Keypad, enter 1-1-1-7 to open the memory (you will hear three rapid beeps) and enter a combination of “5’s” (for every five second increment) and “1’s” (for every one second increment) that equal your desired Door Open Time. Each valid key press (a “1” or a “5”) will generate a double beep.Example: “1-1-1-7 5-5-5-1-1” .. 17 seconds6. After entering your Door Open Time, wait five seconds for the 3 reset beeps... Notes: * Once in Programming Mode, you have 2 minutes to begin programming. You will hear a double beep with each valid key press. Once you begin entering the combination of 1’s and 5’s do not let more than five seconds elapse between entries or the system will reset. Maximum Door Open Time is 120 seconds.

SIK Series Keypad Programming Cont.

8 9

Hardware Setup ContinuedKeypad Illumination:Designed for areas will low ambient lighting, the SIK Series Keypad provides nighttime illumination. Keypad illumination is on by default. This option can be turned OFF by cutting the BLUE Illumwire loop on the back of the Keypad.

Setting Output Options:The SIK Series Keypad provides options for configuring the relay output as well as the grounding outputs. These options include Voltage vs. Dry Contact Output and Latching Authorization for the main output.

Input Requirements:Voltage: 12 to 24 volts AC/DC. System current draw (maximum):Standby: 10mA at 12/24 voltsDuring Operation: .10 amps max

IMPORTANT: The maximum output current allowed is ½ amp. Check the specifications of your locking device. Verify the locking device draws less than ½ amp. For locking devices that draw more current, a separate power supply is required. Note: If connecting DC, make the connections to the Red and Black wires instead of the Gray and White wires. Verify the polarity is correct.

Output Capabilities:The SIK Series Keypad provides one SPDT dry contact relay (rated at 2 amps at 24 VAC). The relay can be configured for one of the following options:Voltage Output: Fail Safe or Fail Secure Locking DeviceDry Contact Output: Control a Gate Operator/Garage DoorTwo auxiliary ¼ Amp grounding outputs are available to drive external relays. These can be configured for CCTV/Light Controller or other device.(First key press triggers a 10 second output)Doorbell or other device: Press the symbol to trigger a 1 second output.

Input & Output

Page 10: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

Hardware SetupRemote Bypass:In some cases, it may be necessary to control the door from a remote area such as a security station or reception desk. The SIK Series Keypad provides for a Remote By-Pass (Exit Switch) or Keypad override. This can be accomplished by connecting a normally open switch from the VIOLET Remote Bypass wire to the BLACK wire. When the Remote By-Pass switch is depressed, the contact bypasses the Keypad and activates the relay for the same time length as the programmed Door Open Time (See Programming Door Open Time . Page 9).

Anti-Tailgating:Some security applications require stricter door monitoring. Anti-tailgating can be controlled by installing a normally closed door monitor switch to the BROWN Door Monitor wire and the BLACK wire on the wire harness. This switch may be the output of a latch monitor switch, a monitor maglock or an alarm switch that senses door movement. When this switch opens, it relocks the door immediately.IMPORTANT: If you wish to use door monitor switch, you must also cut the BROWN Door Monitor wire loop on the back of the Keypad.

Keypad Illumination:Designed for areas will low ambient lighting, the SKE-6L I provides nighttime illumination. Keypad illumination is ON by default. This option can be turned OFF by cutting the BLUE Illumwire loop on the back of the Keypad.

Setting Output Options:The SIK Series Keypad provides options for configuring the relay output as well as the .A grounding outputs. These options include Voltage vs. Dry Contact Output and Latching Authorization for the main output.

Remote Bypass:In some cases, it may be necessary to control the door from a remote area such as a security station or reception desk. The SIK Series Keypad provides for a Remote By-Pass (Exit Switch) or Keypad override. This can be accomplished by connecting a normally open switch from the VIOLET Remote Bypass wire to the BLACK wire. When the Remote By-Pass switch is depressed, the contact bypasses the Keypad and activates the relay for the same time length as the programmed Door Open Time.

Anti-Tailgating:Some security applications require stricter door monitoring. Anti-tailgating can be controlled by installing a normally closed door monitor switch to the BROWN Door Monitor wire and the BLACK wire on the wire harness. This switch may be the output of a latch monitor switch, a monitor maglock or an alarm switch that senses door movement. When this switch opens, it relocks the door immediately.

IMPORTANT: If you wish to use door monitor switch, you must also cut the BROWN Door Monitor wire loop on the back of the Keypad.

10 11

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

Integrating the ST-C5IDS

ST-C5ID(Sold Separately)

(Rear View)

S G P

P-0930

PROCHANNEL TMV ISION

Model P-0930

Whole-House Intercom

Page Out

Page Trigger

IR

Emitters +15VDC

Power

LinkIn

Link Out

Hub

A

B

C

D Room 1 Room 2 Room 3 Room 4 Room 5 Room 6

Press and holddoor station number to activate ST-C5IDS

ST-3000

Connect the orange and green wires from the back of the SIK Keypad into the strike terminals on the ST-C5IDS. The negative wire (cut in two) of the power supply of the strike should also be applied to the strike terminal on the ST-C5IDS. To open the door, press and hold the room button on the ST-3000, or enter the code on the SIK Keypad.

For systems using the P-0930

StrikePowerSupply

Door strike Mechanism

(NOT SOLD BY CHANNEL VISION)

Positive +

N.O

. (O

ran

ge)

Negative-

Ne

ga

tiv

e-

Gro

un

d (

Gre

en

)

Page 11: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

Hardware SetupRemote Bypass:In some cases, it may be necessary to control the door from a remote area such as a security station or reception desk. The SIK Series Keypad provides for a Remote By-Pass (Exit Switch) or Keypad override. This can be accomplished by connecting a normally open switch from the VIOLET Remote Bypass wire to the BLACK wire. When the Remote By-Pass switch is depressed, the contact bypasses the Keypad and activates the relay for the same time length as the programmed Door Open Time (See Programming Door Open Time . Page 9).

Anti-Tailgating:Some security applications require stricter door monitoring. Anti-tailgating can be controlled by installing a normally closed door monitor switch to the BROWN Door Monitor wire and the BLACK wire on the wire harness. This switch may be the output of a latch monitor switch, a monitor maglock or an alarm switch that senses door movement. When this switch opens, it relocks the door immediately.IMPORTANT: If you wish to use door monitor switch, you must also cut the BROWN Door Monitor wire loop on the back of the Keypad.

Keypad Illumination:Designed for areas will low ambient lighting, the SKE-6L I provides nighttime illumination. Keypad illumination is ON by default. This option can be turned OFF by cutting the BLUE Illumwire loop on the back of the Keypad.

Setting Output Options:The SIK Series Keypad provides options for configuring the relay output as well as the .A grounding outputs. These options include Voltage vs. Dry Contact Output and Latching Authorization for the main output.

Remote Bypass:In some cases, it may be necessary to control the door from a remote area such as a security station or reception desk. The SIK Series Keypad provides for a Remote By-Pass (Exit Switch) or Keypad override. This can be accomplished by connecting a normally open switch from the VIOLET Remote Bypass wire to the BLACK wire. When the Remote By-Pass switch is depressed, the contact bypasses the Keypad and activates the relay for the same time length as the programmed Door Open Time.

Anti-Tailgating:Some security applications require stricter door monitoring. Anti-tailgating can be controlled by installing a normally closed door monitor switch to the BROWN Door Monitor wire and the BLACK wire on the wire harness. This switch may be the output of a latch monitor switch, a monitor maglock or an alarm switch that senses door movement. When this switch opens, it relocks the door immediately.

IMPORTANT: If you wish to use door monitor switch, you must also cut the BROWN Door Monitor wire loop on the back of the Keypad.

10 11

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

Integrating the ST-C5IDS

ST-C5ID(Sold Separately)

(Rear View)

S G P

P-0930

PROCHANNEL TMV ISION

Model P-0930

Whole-House Intercom

Page Out

Page Trigger

IR

Emitters +15VDC

Power

LinkIn

Link Out

Hub

A

B

C

D Room 1 Room 2 Room 3 Room 4 Room 5 Room 6

Press and holddoor station number to activate ST-C5IDS

ST-3000

Connect the orange and green wires from the back of the SIK Keypad into the strike terminals on the ST-C5IDS. The negative wire (cut in two) of the power supply of the strike should also be applied to the strike terminal on the ST-C5IDS. To open the door, press and hold the room button on the ST-3000, or enter the code on the SIK Keypad.

For systems using the P-0930

StrikePowerSupply

Door strike Mechanism

(NOT SOLD BY CHANNEL VISION)

Positive +

N.O

. (O

ran

ge)

Negative-

Ne

ga

tiv

e-

Gro

un

d (

Gre

en

)

Page 12: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

Integrating the TE110DS

Telephone Company

Connect the green and orange wires from the keypad to the Unlock Doorterminals on the P-0920 or P-0921. Triggering the keypad will cause the P-0920to activate the TE110DS or the P-0921 to activate the Aux terminal or TE110DSand allow the door to open.

TE110DS(Sold Separately)

12VAC 500mA

StrikeActive

Ring

IntercomActive

12VAC

#o

r* N

o C

O

StrikeTime3

/5 r

ng 1 2 3

PowerIntercomUnlock Door

ChimeCO Input Phones

TELEPHONE ENTRY CONTROLLER

CO Input Telephones

Model P-0920 PROCHANNEL

TMV ISION

HouseTelephones

P-0920

Fail-SecureLock (N.O.)

StrikePowerSupply

+

Inte

rco

m

Ho

use

Strike

The example shown is a P-0920 and normally open lock type.

For systems using P-0920 or P-0921 Garage Door/Gate Operation (Stand-alone keypad operation):

Fail Safe or Fail Secure lock controller and powered by external power supply (Stand-alone keypad operation):

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

12 13

N.O

. (O

ran

ge)

Co

mm

on

(G

reen

)

Typical Output WiringG

rou

nd

(B

lack)

Keyp

ad

Po

wer

12V

DC

+ (

Red

)

Connect direct power orshare power with buttonon the TE-AMP

Page 13: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

Integrating the TE110DS

Telephone Company

Connect the green and orange wires from the keypad to the Unlock Doorterminals on the P-0920 or P-0921. Triggering the keypad will cause the P-0920to activate the TE110DS or the P-0921 to activate the Aux terminal or TE110DSand allow the door to open.

TE110DS(Sold Separately)

12VAC 500mA

StrikeActive

Ring

IntercomActive

12VAC

#o

r* N

o C

O

StrikeTime3

/5 r

ng 1 2 3

PowerIntercomUnlock Door

ChimeCO Input Phones

TELEPHONE ENTRY CONTROLLER

CO Input Telephones

Model P-0920 PROCHANNEL

TMV ISION

HouseTelephones

P-0920

Fail-SecureLock (N.O.)

StrikePowerSupply

+

Inte

rco

m

Ho

use

Strike

The example shown is a P-0920 and normally open lock type.

For systems using P-0920 or P-0921 Garage Door/Gate Operation (Stand-alone keypad operation):

Fail Safe or Fail Secure lock controller and powered by external power supply (Stand-alone keypad operation):

1 / 2

2 / 3

4 / 5

6 / 7

9 / 0

12 13

N.O

. (O

ran

ge)

Co

mm

on

(G

reen

)

Typical Output Wiring

Gro

un

d (

Bla

ck)

Keyp

ad

Po

wer

12V

DC

+ (

Red

)

Connect direct power orshare power with buttonon the TE-AMP

Page 14: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

Typical System Diagram

Wiring Notes:1. This system is designed to control a 12 or 24V locking device.To Control any voltage higher than 24 volts, an external relay must be used. 2. The disable latching capability, cut the green wire loop.3. To disable illumination, cut the blue wire loop.4. If connecting a door monitor switch, cut the green wire loop.5. For a garage or gate opener, remove the DC+ jumper and set door open time to one second. 6. To initiate programming, momentarily short the PGM pins or short the pink wire to the black wire. 7. To prevent inductive kickback, install the factory supplied MOV across the wires to the locking device. (Install as close to the lock itself as possible)

14 5

Keypad Connections - Wiegand 26 Bit Keypad

Important Notes:The default pass-code is 000hDo not apply voltage to the LED hcontrol pinDo not apply voltage to Site Code PGMhDo not apply voltage to Audio ControlhThis keypad does not provide a contact hclosure outputDo not connect this keypad to a door h

Set jumper on far right pin only

Data 0’s

Data 1’s

12vDC In

Keypad Hold

12vDC Ground

LED Control

Site Code PGM

Audio Control

Earth Ground

CCTV

Violet -Prox-Hold

ConfigurationThe All-In-One 12-Pad is capable of generating standard 26 Bit Wiegand data. DATA 1 and DATA 0 signals are open collector outputs with 2.2K pull-ups to the internal +5v. The data is sent at 1 msec per bit with a pulse duration of 50 usec. An annunciator beeps with each key press. When the LED control input is pulled low, the GREEN LED will be on and the RED LED will be off. When the input goes high the RED LED is on and the GREEN LED is off. The LED that is illuminated will blink off with every key press. The LED control input is pulled to the internal +5v with a 2.2K resistor. An output is generated with each key press, which can be used to drive a CCTV or Security Light. Located through the Blue wire (seeConnector Wiring), this is an open collector output capable of sinking1/4 A with a 30 second on time. The following WIEGAND output is sent each time the # (enter) key is pressed:

PS S S S S S S S N N N N N N N N N N N N N N N N PBIT 1 2 9 10 25 26

BIT 1 is an even parity for the following 12 bits.hThe sum of bits 1-13 is even.hBITS 2-9 are the SITE CODE.hBITS 10-25 This is the number(PIN) entered prior to pressing # (enter).hLeading 0’s are added as required. Bit 10 is most significant.hBIT 26 is an odd parity over the previous 12 bits.hThe sum of bits 14-26 is odd.h

Example: The Site Code of 004 and a code of 123 entered1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 1 1 1Note: An error code, which sends all binary 1’s to your panel, isgenerated by any of the following:a. Pressing the # key with no preceding digits.b. Pressing any number of only 0’s prior to pressing the # key.c. Pressing 65,535 or any number above 65,535. Do NOT program your panel to accept code number 65,535.

Page 15: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

Typical System Diagram

Wiring Notes:1. This system is designed to control a 12 or 24V locking device.To Control any voltage higher than 24 volts, an external relay must be used. 2. The disable latching capability, cut the green wire loop.3. To disable illumination, cut the blue wire loop.4. If connecting a door monitor switch, cut the green wire loop.5. For a garage or gate opener, remove the DC+ jumper and set door open time to one second. 6. To initiate programming, momentarily short the PGM pins or short the pink wire to the black wire. 7. To prevent inductive kickback, install the factory supplied MOV across the wires to the locking device. (Install as close to the lock itself as possible)

14 5

Keypad Connections - Wiegand 26 Bit Keypad

Important Notes:The default pass-code is 000hDo not apply voltage to the LED hcontrol pinDo not apply voltage to Site Code PGMhDo not apply voltage to Audio ControlhThis keypad does not provide a contact hclosure outputDo not connect this keypad to a door h

Set jumper on far right pin only

Data 0’s

Data 1’s

12vDC In

Keypad Hold

12vDC Ground

LED Control

Site Code PGM

Audio Control

Earth Ground

CCTV

Violet -Prox-Hold

ConfigurationThe All-In-One 12-Pad is capable of generating standard 26 Bit Wiegand data. DATA 1 and DATA 0 signals are open collector outputs with 2.2K pull-ups to the internal +5v. The data is sent at 1 msec per bit with a pulse duration of 50 usec. An annunciator beeps with each key press. When the LED control input is pulled low, the GREEN LED will be on and the RED LED will be off. When the input goes high the RED LED is on and the GREEN LED is off. The LED that is illuminated will blink off with every key press. The LED control input is pulled to the internal +5v with a 2.2K resistor. An output is generated with each key press, which can be used to drive a CCTV or Security Light. Located through the Blue wire (seeConnector Wiring), this is an open collector output capable of sinking1/4 A with a 30 second on time. The following WIEGAND output is sent each time the # (enter) key is pressed:

PS S S S S S S S N N N N N N N N N N N N N N N N PBIT 1 2 9 10 25 26

BIT 1 is an even parity for the following 12 bits.hThe sum of bits 1-13 is even.hBITS 2-9 are the SITE CODE.hBITS 10-25 This is the number(PIN) entered prior to pressing # (enter).hLeading 0’s are added as required. Bit 10 is most significant.hBIT 26 is an odd parity over the previous 12 bits.hThe sum of bits 14-26 is odd.h

Example: The Site Code of 004 and a code of 123 entered1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 1 1 1Note: An error code, which sends all binary 1’s to your panel, isgenerated by any of the following:a. Pressing the # key with no preceding digits.b. Pressing any number of only 0’s prior to pressing the # key.c. Pressing 65,535 or any number above 65,535. Do NOT program your panel to accept code number 65,535.

Page 16: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

PINK - Site Code Program:This Keypad is capable of having the SITE CODE programmed in the field. The PINK wire is used for this procedure. With no voltage applied to the Keypad, connect the PINK wire to the BLACK wire on the wiring harness.

Apply the appropriate voltage to the RED and BLACK wires. You will hear 4 rapid audible beeps and both the RED and GREEN LED's will flash at the same rate. Enter the desired SITE CODE (between 0 and 255) on the Keypad and press # for enter. You will again hear 4 rapid audible beeps. At this point the Keypad will appear non-functional and will not accept any entries. (If the wrong key is pressed during the programming sequence, pressing the * key will clear the entry. You will then hear 2 rapid beeps and both LED’s will flash at the same rate. The Keypad will generate an error tone if you enter a SITE CODE over 255.)Disconnect power to the RED wire and disconnect the PINK wire from the BLACK wire.Now you can connect the standard Wiegand 5 wires to the Keypad and the programmed SITE CODE will be generated as part of the 26 Bit data when the enter key (#) is pressed. This procedure may be repeated to change the SITE CODE. The factory default site code is 000.

BLUE- CCTV:Pressing any position on the Keypad will generate a 30-second, 0.25 Amp, intermittent duty grounding output on the BLUE wire.

ORANGE- Keypad Buffered/Hold, VIOLET- Prox Buffered/Hold:When the Hold Line is pulled low, codes (card numbers) entered on the Keypad (Prox Reader) are stored in the buffer. When the Hold Line is released to a logic high, the buffered data is sent. This input is pulled high with a 2.2K resistor.

YELLOW- Audio Control:Pulling YELLOW low (grounding) causes the beeper to sound.

TAN- Case Ground:In higher static prone areas, the TAN wire is used to divert static discharge away from the microprocessor in the Keypad. Ideally, the TAN wire should be connected to a known Earth Ground or the Black wire at the Keypad installation point (Do NOT run back to the equipment through the cable).

Keypad Configuration - Wiegand 26 Bit Keypad Configuration - Wiegand 26 BitVoltage Selection:The factory default setting for the Keypad voltage is 12VDC. Verify that the jumper is removed or placed over only one pin. Do not change the voltage.

Keypad Reset: In certain cases you may want to restore system defaults. To perform this procedure: CAUTION: This completely erases the memory & restores factory defaults!

1. Remove power.2. Jumper the two pins above the connector labeled “CONFIG.”3. Apply appropriate power. (You should hear 4 beeps and the RED LED will flash and the GREEN LED will be solid).4. Once the Keypad is in configuration mode, enter 0099#. The Keypad will beep twice and both LEDS will flash for approximately 10 seconds. (During this time, the Keypad will appear dead. Do NOT remove power!)5. Once the reset is complete, you will hear 4 beeps and the RED LED will flash and the GREEN LED will be solid.6. Enter the configuration number followed by # A. Keypad Output Keypad Output Configuration Site Code 26 Bit Wiegand (default) 1 # 000

B. To change the audible beep, enter Code Audible Beep 201 # Normal Beep (factory default) 200 # Short Click (quieter)

C. To change the illumination, enter the code as follows: Code Standby Mode Normal Operation 210 # Off (factory default) Off (factory default) 211 # Off Dim 212 # Off Bright 213 # Dim Dim 214 # Dim Bright You should hear 3 beeps indicating successful configuration(the RED LED will continue to flash and the GREEN LED will be solid). If you hear a long error beep, re-enter the configuration number followed by #.

7. Remove power.8. Remove configuration jumper.9. Re-apply power.10. RED LED on, GREEN LED off.Prox reader is HID 125kHz with Data 0 on Green, Data 1 on White

76

Page 17: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

PINK - Site Code Program:This Keypad is capable of having the SITE CODE programmed in the field. The PINK wire is used for this procedure. With no voltage applied to the Keypad, connect the PINK wire to the BLACK wire on the wiring harness.

Apply the appropriate voltage to the RED and BLACK wires. You will hear 4 rapid audible beeps and both the RED and GREEN LED's will flash at the same rate. Enter the desired SITE CODE (between 0 and 255) on the Keypad and press # for enter. You will again hear 4 rapid audible beeps. At this point the Keypad will appear non-functional and will not accept any entries. (If the wrong key is pressed during the programming sequence, pressing the * key will clear the entry. You will then hear 2 rapid beeps and both LED’s will flash at the same rate. The Keypad will generate an error tone if you enter a SITE CODE over 255.)Disconnect power to the RED wire and disconnect the PINK wire from the BLACK wire.Now you can connect the standard Wiegand 5 wires to the Keypad and the programmed SITE CODE will be generated as part of the 26 Bit data when the enter key (#) is pressed. This procedure may be repeated to change the SITE CODE. The factory default site code is 000.

BLUE- CCTV:Pressing any position on the Keypad will generate a 30-second, 0.25 Amp, intermittent duty grounding output on the BLUE wire.

ORANGE- Keypad Buffered/Hold, VIOLET- Prox Buffered/Hold:When the Hold Line is pulled low, codes (card numbers) entered on the Keypad (Prox Reader) are stored in the buffer. When the Hold Line is released to a logic high, the buffered data is sent. This input is pulled high with a 2.2K resistor.

YELLOW- Audio Control:Pulling YELLOW low (grounding) causes the beeper to sound.

TAN- Case Ground:In higher static prone areas, the TAN wire is used to divert static discharge away from the microprocessor in the Keypad. Ideally, the TAN wire should be connected to a known Earth Ground or the Black wire at the Keypad installation point (Do NOT run back to the equipment through the cable).

Keypad Configuration - Wiegand 26 Bit Keypad Configuration - Wiegand 26 BitVoltage Selection:The factory default setting for the Keypad voltage is 12VDC. Verify that the jumper is removed or placed over only one pin. Do not change the voltage.

Keypad Reset: In certain cases you may want to restore system defaults. To perform this procedure: CAUTION: This completely erases the memory & restores factory defaults!

1. Remove power.2. Jumper the two pins above the connector labeled “CONFIG.”3. Apply appropriate power. (You should hear 4 beeps and the RED LED will flash and the GREEN LED will be solid).4. Once the Keypad is in configuration mode, enter 0099#. The Keypad will beep twice and both LEDS will flash for approximately 10 seconds. (During this time, the Keypad will appear dead. Do NOT remove power!)5. Once the reset is complete, you will hear 4 beeps and the RED LED will flash and the GREEN LED will be solid.6. Enter the configuration number followed by # A. Keypad Output Keypad Output Configuration Site Code 26 Bit Wiegand (default) 1 # 000

B. To change the audible beep, enter Code Audible Beep 201 # Normal Beep (factory default) 200 # Short Click (quieter)

C. To change the illumination, enter the code as follows: Code Standby Mode Normal Operation 210 # Off (factory default) Off (factory default) 211 # Off Dim 212 # Off Bright 213 # Dim Dim 214 # Dim Bright You should hear 3 beeps indicating successful configuration(the RED LED will continue to flash and the GREEN LED will be solid). If you hear a long error beep, re-enter the configuration number followed by #.

7. Remove power.8. Remove configuration jumper.9. Re-apply power.10. RED LED on, GREEN LED off.Prox reader is HID 125kHz with Data 0 on Green, Data 1 on White

76

Page 18: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

Two Year Limited WarrantyChannel Vision Technology will repair or replace any defect in material or workmanship which occurs during normal use of this product with new or rebuilt parts, free of charge in the USA, for two years from the date of original purchase. This is a no hassle warranty with no mail in warranty card needed. This warranty does not cover damages in shipment, failures caused by other products not supplied by Channel Vision Technology, or failures due to accident, misuse, abuse, acts of God, or alteration of the equipment. This warranty is extended only to the original purchaser when purchased through an authorized reseller. A purchase receipt, invoice, or other proof of original purchase date will be required before warranty repairs are provided.Mail in service can be obtained during the warranty period by calling (800) 840-0288 toll free. A Return Authorization number must be obtained in advance and can be marked on the outside of the shipping carton.This warranty gives you specific legal rights and you may have other rights (which vary from state to state). If a problem with this product develops during or after the warranty period, please contact Channel Vision Technology, your dealer or any factory-authorized service center.Channel Vision products are not intended for use in medical, lifesaving, life sustaining or critical environment applications. Channel Vision customers using or selling Channel Vision products for use in such applications do so at their own risk and agree to fully indemnify Channel Vision for any damages resulting from such improper use or sale.

500-379 rev A

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

Tested To ComplyWith FCC Standards

234 Fischer Avenue, Costa Mesa, California 92626 USA(714)424-6500 (800)840-0288 (714)424-6510 fax email: [email protected]

• Intelligent Entertainment • Infrastructure • Security Solutions

w w w . c h a n n e l v i s i o n . c o m

These are a few troubleshooting suggestions to help assist with any problems you may experience. You may contact Channel Vision Technical Support at (714) 424-6500 option two, or email [email protected]

Changed or Deleted a code and the old code still works:The SIK Series Keypad has a total of 6 User Codes. Make sure you’ve changed the desired code. If you changed the Master Code, the other User Codes will still work. If in doubt, it is recommended you reprogram the master code and delete all 5 user codes. Then program any new user codes.

Keypad beeps but the door does not unlock:If the Keypad beeps but an authorized code does not open/unlock the door, there is an easy test to check the wiring hookup to the locking device. Locate the VIOLET “Remote” wire and momentarily short to the BLACK wire. This will activate the output (same as if you enter a valid programmed code at the Keypad). If this test does not activate the lock, you may have wired the lock incorrectly to the SIK Series Keypad (See page 14, Typical System Diagram.) If this test does activate the output (you should hear the relay click and the locking device should unlock), then the problem may be:Programming - If the unit has just been installed, the problem is most likely with programming the system codes. Review Overview and Programming of User Codes again remembering that all six codes have to be different from each. It is also important not to let more than 5 seconds elapse between button presses or the system will reset and you will have to start over.Code Loss - (Existing installations) There are typically two reasons for code loss: static or inductive kickback. There is no way to determine if the system has been affected by either of these, however, you can reprogram the system codes as described in User Code Programming. It is very important the system is properly grounded otherwise static and code loss may be an ongoing problem.

Keypad does not power up:First, check your power supply to see that power has not been cut off. Using a voltmeter, check the incoming voltage on the GRAY and WHITE wires (12-24V AC/DC IN). If the voltage reads low, the electric locking device may be drawing too much current. To test, remove the wires to the device and recheck the voltage. If the voltage now reads normal, check the current draw of the locking device and make sure it falls within the system specifications (see Input Requirements).

Random Beeping:Possible low voltage or bad power supply. Also, check EARTH ground.

15

Troubleshooting

(TOperating Voltage - Keypad: 12vDC 100mAOperating Voltage - Communication: 12vDC 60mAOperating Voltage - IP Camera: POE 802.3af or 12vDC 500mACable Requirements - IP Camera: 1 CAT5/6 with POE for cameraCable Requirements- Communication: 1 18/2 power wire for amplified companion board, button & keypad 2 Conductor CAT5/6 for companion board (communication) 2 Conductor CAT5/6 for keypadSpeaker impedance: 8 ohmOperating Temperature: -10ºC to +50ºC

ypical at 77º)

Page 19: -XXXXA-XX SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK …channelvision.com/wp-content/uploads/Instruction-Manuals/SIK-xxxx... · SIK SIK-XXXXC-XX SIK-XXXXP-XX SIK-XXXXI-XX SIK-XXXXSK-XX-XXXXA-XX

Two Year Limited WarrantyChannel Vision Technology will repair or replace any defect in material or workmanship which occurs during normal use of this product with new or rebuilt parts, free of charge in the USA, for two years from the date of original purchase. This is a no hassle warranty with no mail in warranty card needed. This warranty does not cover damages in shipment, failures caused by other products not supplied by Channel Vision Technology, or failures due to accident, misuse, abuse, acts of God, or alteration of the equipment. This warranty is extended only to the original purchaser when purchased through an authorized reseller. A purchase receipt, invoice, or other proof of original purchase date will be required before warranty repairs are provided.Mail in service can be obtained during the warranty period by calling (800) 840-0288 toll free. A Return Authorization number must be obtained in advance and can be marked on the outside of the shipping carton.This warranty gives you specific legal rights and you may have other rights (which vary from state to state). If a problem with this product develops during or after the warranty period, please contact Channel Vision Technology, your dealer or any factory-authorized service center.Channel Vision products are not intended for use in medical, lifesaving, life sustaining or critical environment applications. Channel Vision customers using or selling Channel Vision products for use in such applications do so at their own risk and agree to fully indemnify Channel Vision for any damages resulting from such improper use or sale.

500-379 rev A

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

Tested To ComplyWith FCC Standards

234 Fischer Avenue, Costa Mesa, California 92626 USA(714)424-6500 (800)840-0288 (714)424-6510 fax email: [email protected]

• Intelligent Entertainment • Infrastructure • Security Solutions

w w w . c h a n n e l v i s i o n . c o m

These are a few troubleshooting suggestions to help assist with any problems you may experience. You may contact Channel Vision Technical Support at (714) 424-6500 option two, or email [email protected]

Changed or Deleted a code and the old code still works:The SIK Series Keypad has a total of 6 User Codes. Make sure you’ve changed the desired code. If you changed the Master Code, the other User Codes will still work. If in doubt, it is recommended you reprogram the master code and delete all 5 user codes. Then program any new user codes.

Keypad beeps but the door does not unlock:If the Keypad beeps but an authorized code does not open/unlock the door, there is an easy test to check the wiring hookup to the locking device. Locate the VIOLET “Remote” wire and momentarily short to the BLACK wire. This will activate the output (same as if you enter a valid programmed code at the Keypad). If this test does not activate the lock, you may have wired the lock incorrectly to the SIK Series Keypad (See page 14, Typical System Diagram.) If this test does activate the output (you should hear the relay click and the locking device should unlock), then the problem may be:Programming - If the unit has just been installed, the problem is most likely with programming the system codes. Review Overview and Programming of User Codes again remembering that all six codes have to be different from each. It is also important not to let more than 5 seconds elapse between button presses or the system will reset and you will have to start over.Code Loss - (Existing installations) There are typically two reasons for code loss: static or inductive kickback. There is no way to determine if the system has been affected by either of these, however, you can reprogram the system codes as described in User Code Programming. It is very important the system is properly grounded otherwise static and code loss may be an ongoing problem.

Keypad does not power up:First, check your power supply to see that power has not been cut off. Using a voltmeter, check the incoming voltage on the GRAY and WHITE wires (12-24V AC/DC IN). If the voltage reads low, the electric locking device may be drawing too much current. To test, remove the wires to the device and recheck the voltage. If the voltage now reads normal, check the current draw of the locking device and make sure it falls within the system specifications (see Input Requirements).

Random Beeping:Possible low voltage or bad power supply. Also, check EARTH ground.

15

Troubleshooting

(TOperating Voltage - Keypad: 12vDC 100mAOperating Voltage - Communication: 12vDC 60mAOperating Voltage - IP Camera: POE 802.3af or 12vDC 500mACable Requirements - IP Camera: 1 CAT5/6 with POE for cameraCable Requirements- Communication: 1 18/2 power wire for amplified companion board, button & keypad 2 Conductor CAT5/6 for companion board (communication) 2 Conductor CAT5/6 for keypadSpeaker impedance: 8 ohmOperating Temperature: -10ºC to +50ºC

ypical at 77º)