Upload
interlatin-test-division
View
469
Download
2
Embed Size (px)
Citation preview
Agilent Technologies InterLatin
i3070 Licensing & Updates
Agenda
• Agilent’s SW licensing scheme
• SW Updates and Support Contracts
• i3070 Series 5 New Hardware changes
• Firmware Changes
• Compatibility Challenges
Page 3
Licensing Scheme
• In the purchase of a new 3070 system,
Agilent offer three types of licenses:
•Basic Licenses (included in the system)
•Extra Feature Licenses
•Anual Based Licenses
Page 4
Licensing Scheme
• Basic Licenses
•Automatic Program Generator
•TestJet/VTEP
•Full analog and digital (powered test) In-Circuit Test
•Flash70 Programming
•Panel Test
•Throughput Multiplier
•Polarity Check
•External DLL calling
•Test Development SW for 1 PC
Page 5
Licensing Scheme
• Extra Licenses (extra cost)
•Timing Sets (combo test)
•Boundary Scan Interconnect (advanced Bscan)
•1149.6 Advanced Boundary Scan (advanced I/O Bscan)
•Silicon Nails (Development and Run)
•DriveThru Test
•Dynamic Test Access Suite (Flash ISP, PLD ISP)
•Test Development SW (extra PCs)
•Cover Extend Technology (extra HW needed)
•TestSight Conversion SW
•Agilent Test Coverage Consultant
Page 6
Licensing Scheme
• Anual Based Licenses (extra cost)
•Advanced Diagnostics License
•Calibration License
•These two licenses expire within the year and are renowed for customers
with support contract with Agilent.
Page 7
SW Updates
• Agilent offers a one-time Software Update to have the latest
version of the 3070 Software (current version: 8.30pd). This
item includes one-year of SW updates.
• If a system is adquired with another party that is not Agilent, a
License Transfer Fee should be paid to legally use the
Software of the 3070 System.
Page 8
Agilent Support Contracts • Agilent offers some different Flexible Schems in Support
Contracts:
•ICT Max Services
•ICT Flex Services
Agilent Support Contracts
• Hardware Support:
– 24x7 On-site Support (basically 5DX)
• Same day response (4 hours max.)
• Engineer on-site support
• Parts exchange (depending availability)
– 8x5 Cooperative Support (5DX, SJ50, 3070)
• Next day response
• Phone support only
• Parts exchange (depending availability)
Agilent Support Contracts
• Support Process & Escalation Path – Report failure to Interlatin Test Services
• Email: [email protected] • Provide: Serial Number, Problem description (Part Number
Needed) and Contact Information
– If urgent help is needed, dial InterLatin 800 Number • Phone: 1 800-716-9586 option 5
– If in four hours no response from Test Services • Contact Edie Haro ([email protected] – 33
31565493)
– If in eight hours no response from Edie Haro • Contact Francisco de Alba ([email protected] – 33
10952950)
i3070 Series 5 HW changes
• New ASRU-N card
• New Control XTPA card
• New Hybrid cards
• New iCap
• New Utility Card
New ASRU-N card
• Available for version 8.x
• Faster in analog tests with Speed-up option.
• New power Monitoring circuit.
• Added two more freq. to test small capacitors
• High Voltage Zener Test
Page 13
How to use ASRU Speed-up feature
• Regenerate test sources using IPG Test
Consultant
• Next, click Action -> develop board test.
• Click ‘Begin Interactive Development’, you can
marked the following as “skip:
• Generate Initial Fixture Files
• Create Custom Tests
• Generate Test Requirements Files
• Generate Final Fixture Files and Reports
• Generate “testplan”
• When prompt, click Override button.
• You have following marked as “do”:
• Generate Tests Using IPG
• Generate Test Object Files
• Recalculate Depencies
• Click “Actions All Steps To Stop Mark”.
• Once complete, you can start debugging the
tests.
Page 14
cards 1 asru n revision must declared in board config
How to use ASRU Speed-up feature
No Regenerate, manually insert “as” option
ASRU Speed-up feature – Best Practice
For Pre_short Test:
• Always use “ar1” - this is to avoid detector going into auto-ranging mode which will increase some test time.
For Analog Tests such as capacitor, inductor and resistor:
• Test unstable, do not use “ed”. Revert back to “MOA” test
• Always set the correct asru range (ar) to avoid auto-ranging mode
– Use this formula Ar = Vout = (Rref / ZDUT * Vs) (Note: Vs default is 0.1)
– ZDUT can be R or C=1/2(pi)FC and L=2(pi)FL
Page 16
Digitized Measurement Circuit - New Frequency option
• Ranges are 100k and 200khz
New Control XTPA card
November 19, 2013 17
XTP XTPA
Part Number: N1807-66801 Part Number: E9900-66506
• Available for version 8.30pd
New Control XTPA card
• PCBA changes – Lead Free PCB & ROHS compliant devices
– 20 critical parts replaced • Ethernet controller chipset
• EDO RAM
• Multi-Functional Peripheral (MFP)
• DDR2 SDRAM (obsolete EDO DIMM)
• Shielded RJ45 Jack
• Removal of unused MINT pins
• Removal of Thin LAN ports
New Hybrid Cards
• 6 & 12MPS
• Changed Relays PN for more reliability.
• Changed Driver/Receiver IC due to obsolescence.
New ICap card
Page 20
System card controller and LAN port
Auxiliary ports 6 to 9 and relays
Compress air relays and power supplies connection
Auxiliary ports 1 to 5 and relays
Required verdion 08.10p
Medalist In-Circuit Test 08.10p Software Release Agilent
Confidential 16th July 2010
Page 21
i3070 System Level Configuration
Controller
Ethernet Hub/Switch
Coax-Twisted Pair Converter
System Card
Coaxial
Twisted Pair
Twisted Pair
Control XT/XTP
Control XT/XTP
Control XT/XTP
Control XT/XTP
Current Configuration iCap card Configuration for Control XT/XTP/XTPA
Coaxial
Controller
Ethernet Hub/Switch
Coax-Twisted Pair Converter
Icap Card
Twisted Pair
Twisted Pair
Control XT/XTP
Control XT/XTP
Control XT/XTP
Control XT/XTP
Coaxial
Twisted Pair
Medalist In-Circuit Test 08.10p Software Release Agilent
Confidential 16th July 2010
New Utility Card
• Allows customers to add their own custom circuit on to the testhead through this card.
• Also includes: • 2x high current (multiplex-able)
power supply ports (10A capable) • 2x 4:1 balanced muxed ports for
connection of differential signals from external instruments (can also connect single output signals)
• 8x GP relays
• Working with 3rd party vendors for programming cards
i3070 Firmware Changes
• Applicable to Series 5 12MPS hybrid cards and Control XTPA cards with Version 8.x and above.
Compatibility Issues
• 12MPS hybrid cards with old firmware are not detected in a Series 5 system with Version 8.x or later. The firmware of the hybrid card should be updated.
• Control XT & XTP cards should be firmware updated to run in a Series 5 with version 8.x or later.
• When changing to a Windows controller an specific Network configuration (firewall) should be followed to avoid lost-heartbeat errors.
Compatibility Issues
• X-Vision start-up issue can be solved updating the X-Vision to latest version.
• The new Hybrid Cards have a slower transience in pull-up/pull-down circuits. Run “diagnose fault, verbose” and follow recommendations to fix this error in digital tests.
Q&A