Our double duct heat pumps are ideal for modular or prefab buildings. In addition the uniqueness of our product lends itself to temporary buildings. Finally our virtual plug and play concept will provide much needed cooling or heating to those with cabins or cottages. Please take a moment to view the attached pdf file for more information.
Citation preview
1
High Efficiency Single Chassis “Monobloc” Heat Pump A unique solution Provides cooling and heating for : Mobile Homes/Cottages/Cabins Residential Containers/Pre Fabrication Units Portable/Temporary Offices
Ambient-Operating range between
- 4F (-20°C) to + 125.6F (+ 52°C)
Sonkor International Sales Presentation: DD Monobloc (1)
2
Application Product Solution
Mobile/Pre Fabricated Units
The special lightweight construction of mobile homes and residential prefabs provide good insulation in winter but not in summer. Unit placement is sometimes unclear until the actual time of sale, which could mean a variety of temperature and humidity ranges.
Product Range
The full range of Sonkor heat pumps adapts well to extreme conditions from the bitter cold of northern countries to dry or damp heat locations such as in Africa, Asia, India, USA, Latin America.
Superior to Window and Splits
Our cylinder block heat pump was uniquely designed for this type of application and offers many advantages over window, package or traditional split systems, including ease of installation and unique performance .
Sonkor International Sales Presentation: DD Monobloc (1)
3
Mobile Homes/Cabins Container Housing Temporary Offices
Cottages/Cabins/Pre Fabs
Special attention was devoted to the acoustic insulation of heat pumps allowing the units to be installed in any room configuration: living room, bedroom, guest rooms, etc.
Day and Night: Simple Comfort
Used on job sites or even small office buildings - in either case you will need powerful machines to meet the ever-changing thermal loads. Our product range provides a solution for these needs with the utmost respect of environmental and acoustic comfort.
Strong Thermal Loads
These applications have high thermal loads especially in summer conditions. Adding to the external loads are items such as computers, lamps and heat generated from people. Thanks to the special fresh air intake feature our heat pumps ensures optimum comfort whilst also providing a high level of air quality and low concentrations of C02.
Applications Sonkor International Sales Presentation: DD Monobloc (1)
4
Products and Solutions
High wall - iCool and iWarm Product Range
There are four product configurations including an EC motor option de-signed to improve energy efficiency and increase the COP and EER of the units. An additional option is the possibility to add 1600 watts of back up heat. The unit will work up to minus 4 degrees Fahrenheit (minus 20 de-grees Centigrade). Our sleek design measures only 7.7 inches (19.5 centi-meters) in depth and includes activated carbon filters.
Low wall - PTTW Product Range
The low wall product range also consists of four models configured with AC or EC motors. One of the versions is equipped with 2000 watts of back up heat, which allows for continuous operation of the unit up to - 4F (-20°C). Hot gas bypass, on board controls, and an indoor air exchange system are just a few of the many features. Extremely compact measuring only 9.45 inches (24 centimeters) in depth. This is a very attractive design with many options.
No Outdoor Unit Required Sonkor International Sales Presentation: DD Monobloc (1)
5
Simplified Installation Ultra Quiet Ecological
Two Tubes
Installation is easy requiring only two holes on the outside wall. In installations where outside tempera-tures reach below 32°F (0°C), we recom-mend the installer connect the condensate outlet for heat pump operation. Additionally, the possibililty of theft or tampering is greatly reduced since the unit is located 100% on the inside of the building.
Ultra Quiet
Our use of Expanded Polypropylene (EPP) and insulating fibers provide levels of soundproofing impossible with traditional window or package type units. The units offer a comfortable low noise level at the top of it’s class.
Ecology and low energy
consumption
The use of high efficiency motors and compressors help obtain the minimum COP and EER levels to comply with the European Energy labeling Directive 2013 and 2014 and in North America the DOE/AHRI standards 210/240-2008 (Window units) 310/380-2004 (PTAC) .
Benefits Sonkor International Sales Presentation: DD Monobloc (1)
6
Low Wall Mount High Wall Mount CO2 Minimized
Low Wall Range
Our floor range is aesthetic to the eye and competes quite favorably against tradition-al compact fan coils. Attractive in design with on board controls.
High Wall Range
For those preferring a high wall unit our unique design appears to be as a tradi-tional split unit but has all the advantage of being self contained on the inside of the building. The lower flap and adjustable au-to louver are designed to distribute opti-mally the air in the surrounding environ-ment.
Fresh Air Exchange
The presence of fresh air exchange in both product platforms guarantees a con-stant fresh air intake rate of 30-40 m3/h. This is particularly useful in bedrooms or offices, where the CO2 levels tend to in-crease with the presence of people. This is a plus not found in traditional split type units.
Benefits Sonkor International Sales Presentation: DD Monobloc (1)
7
-4F (–20°C) Outdoor +125.6F (+52°C) Outdoor On Board Controls
Low and High Wall Units
Air-to-air heat pumps, such as split, window, and package units have problems of not providing the necessary thermal power when the outside temperature drops below 32 degrees F (0 degrees C). Our range ensures maximum comfort even in these extreme conditions, reducing the dependency of defrost cycling through the use of a hot gas bypass system.
T3 - Tropicalized Performance
Our rigorous testing helps ensure smooth operation and minimal reduction in performance of the units even in extreme tropical conditions:
90F (32°C) indoor temperature
125.6F (52°C) outdoor temperature
This is made possible through the generous heat exchangers and air flow.
Practicality
In addition to offering remote controls the units have on board controls for ease of use. Both low and high wall units come with infrared hand held remote con-trols.
Additional Benefits Sonkor International Sales Presentation: DD Monobloc (1)
8
Certifications 3D air diffusion Lower Total Costs
TUV CE - ETL - RoHS
Our entire product range is TUV Rheinland or ETL certified. This allows us to provide maximum electrical safety and reduction of claims.
Additional certifications include CE mark + RoHS and EMC.
High Wall
Our unique three-dimensional air distribu-tion system allows the unit to reach set point quickly. This unique feature is not available in conventional window, split, package type air conditioners.
Project Savings
Low installation and maintenance costs plus lower risk of refrigerant leaks when compared to split units, are just some of the strengths of our innovative product so-lution. Our heat pumps are ideal for manufactur-ers of mobile homes and container housing. In the end we provide a winning solution in terms of total cost.
Additional Benefits Sonkor International Sales Presentation: DD Monobloc (1)
9
iCool iCool ECM
High Efficiency MODEL
Total cooling capacity kW 2.01 2.01
Heating capacity kW 2.01 2.01
Electric heat booster kW - -
Power input W 837 770
EER rating (Class) W/W 2.49 (B) 2.71 (A)
COP rating (Class) W/W 2.90 (B) 3.20 (A)
Performance Certification Own lab Own lab
Air volume CMH 390 390
Fan speed 3+Auto 3+Auto
Dehumidification l/h 0.7 1.0
Indoor sound pressure level @ 1 metre dB(A) 42/46/49 42/46/49
Outdoor sound pressure level @ 1 metre dB(A) 50/56/60 50/56/60
Serial BUS communication (protocol) Standard (MODBUS) Standard (MODBUS)
Electrical supply V/ph/Hz 230/1/50 230/1/50
Refrigerant R410a R410a
Dimensions - Width mm 950 950
Dimensions - Height mm 430 430
Dimensions - Depth Mm 195 195
Net weight kg 38 39
Wall hole diameter mm 200 200
Certification TUV CE/RoHS/ETL TUV CE/RoHS/ETL
From 32F (0°C) to 125.6F (52°C) External Sonkor International Sales Presentation: DD Monobloc (1)
High Wall
10
iWarm iWarm ECM
High Efficiency MODEL
Total cooling capacity kW 2.01 2.01
Heating capacity (incl. electric heat) kW 2.01 (3.61) 2.01 (3.61)
Electric heat booster kW 1.6 1.6
Power input (electric heat) W 837 (1,600) 770 (1,600)
EER rating (Class) W/W 2.49 (B) 2.71 (A)
COP rating (Class) W/W 2.90 (B) 3.20 (A)
Performance Certification Own lab Own lab
Air volume CMH 390 390
Fan speed 3+Auto 3+Auto
Dehumidification l/h 0.7 1.0
Indoor sound pressure level @ 1 metre dB(A) 42/46/49 42/46/49
Outdoor sound pressure level @ 1 metre dB(A) 50/56/60 50/56/60
Serial BUS communication (protocol) Standard (MODBUS) Standard (MODBUS)
Electrical supply V/ph/Hz 230/1/50 230/1/50
Refrigerant R410a R410a
Dimensions - Width mm 1010 1010
Dimensions - Height mm 430 430
Dimensions - Depth mm 195 195
Net weight kg 38 39
Wall hole diameter mm 200 200
Certification TUV CE/RoHS/ETL TUV CE/RoHS/ETL
From 32F (0°C) to 125.6F (52°C) External Sonkor International Sales Presentation: DD Monobloc (1)
High Wall
11
Low Wall
PTTW-09 PTTW-12 MODEL
Total cooling capacity kW 2.46 3.25
Heating capacity (incl. electric heat) kW 2.78 3.33 (3.83)
Electric heat booster kW - 500
Power input (electric heat) W 980 1370 (500)
EER rating (Class) W/W 2.53 (B) 2.43 (B)
COP rating (Class) W/W 2.83 (B) 2.60 (C)
Performance Certification Own lab Own lab
Air volume CMH 400 480
Fan speed 3+Auto 3+Auto
Dehumidification l/h 0.8 1.1
Indoor sound pressure level @ 1m dB(A) 37/40/46 37/44/48
Outdoor sound pressure level @ 1m dB(A) 43 41/52
Serial BUS communication (protocol) Optional (MODBUS) Standard (MODBUS)
Electrical supply V/ph/Hz 230/1/50 230/1/50
Refrigerant R410a R410a
Dimensions - Width mm 1000 1000
Dimensions - Height mm 580 580
Dimensions - Depth mm 230 245
Net weight kg 40 42
Wall hole diameter mm 162 162
Certification TUV CE / RoHS / ETL TUV CE / RoHS / ETL
From 25F (–4°C) to 125.6F (52°C) External Sonkor International Sales Presentation: DD Monobloc (1)
12
Low Wall
MODEL PTTW-10-ECM-EH
High Efficiency PTTW-10-ECM High Efficiency
Total cooling capacity kW 2.90 2.90
Heating capacity (incl. electric heat) kW 2.96 (4.96) 2.96
Electric heat booster kW 2.00 -
Power input (electric heat) W 905(2000) 905
EER rating (Class) W/W 3.27 (A++) 3.27 (A++)
COP rating (Class) W/W 3,51 (A++) 3.51 (A++)
Performance Certification SGS Institute SGS Institute
Air volume CMH 450 450
Fan speed 3+Auto 3+Auto
Dehumidification l/h 1.0 1.0
Indoor sound pressure level @ 1m dB(A) 37/44/48 37/44/48
Outdoor sound pressure level @ 1m dB(A) 41/52 41/52
Serial BUS communication (protocol) Standard (MODBUS) Standard (MODBUS)
Electrical supply V/ph/Hz 220/1/60 230/1/50
220/1/60 230/1/50
Refrigerant R410a R410a
Dimensions - Width mm 1000 1000
Dimensions - Height mm 580 580
Dimensions - Depth mm 245 245
Net weight kg 42 42
Wall hole diameter mm 162 mm 162 mm
Certification TUV CE / RoHS / ETL TUV CE / RoHS / ETL
From 25F (–4°C) to 125.6F (52°C) External Sonkor International Sales Presentation: DD Monobloc (1)