_1m _3m _5m _10m0
Lounge
Dining
Media room
Kitchen
Study
Utility room
Vault above
Outside dining
WC
Garage
459.0 6000.0
3431.0
2533.0
838
Doo
r83
8 D
oor
762 Door2063.0
1647.0
SVP
Open up existingcavity and alignafter inspection
Fan outlet 15L/SEXCT FAN
AV Cupb'd St.
BBQ client toconfirm
Fireplace to clientsspecification
SVP
STAIRCASE:Timber:Part K15 Risers =186mm.Goings = 220mm.Pitch = 40°
rwp
659.0
4800.0
300.0
1100.0
1400.0
1100.0
900.0
6233.0
1083.0
2500.0
2500.0
300.0
940.0
407.0
100.0
912.0
347.0
900.0
600.0
2043.0
St. St.
600mm x 600mmPaving slabs
Timber Louvre's -client to confirmspecification
Bedroom
Bedroom
Bedroom
En-Suite
En-suite
Bedroom
Bathroom
12783.0
1200.0 3044.0 2575.0 875.0 2030.0 2159.0 900.0
11581.0
5666.0
1200.0
4715.0
11581.0
6233.0
1200.0
4148.0
12783.0
450.0 3268.0 1594.0 2159.0 2228.0 2159.0 925.0
Insulated cavity closers to allproposed doors and windows .
3655.0
4497.0
1800.0
3618.0
3642.0
4910.0
1900.0
3618.0
3000.0
3641.0
4890.0
2825.0
4448.0
2825.0
2329.0
4293.0
2600.0
2825.0
1200.0
5968.0
1150.0
1171.0
838 Door
838
Doo
r
838
Doo
r
838 Door
FD30 838
FD30 838
FD30
838
838 Door
SVP
SVP
Fan outlet 15L/SEXCT FAN
Fan outlet
15L/SEXCT FAN
TowelRail
Fan outlet
15L/SEXCT FAN
SVP
rwp
838 Door
TowelRail
838 Door protruding lightbox toelectriciansspecification
Velux TWF -Flexible suntunnel
WALL LEGEND
BLOCK AND BEAM'
'Periscopic' type vents to manufacturers details
30mm Finish Render
100mm Concrete Block
50mm Cavity
50mm Celotex
100mm Thermalite Turbo block ( to achieve K value of 0.11)
12.5mm plasterboard on 10mm dabs, taped and skimmed
STUD WORK
70mm Metal Studwork
25MM Wool batts internally (minimum thickness 25MM, Minimum
density 10 KG/M3)
15MM Plasterboard to both sides all joints to be taped and skimed.
Smoke detectorMains powered single station smoke detector units in strict
accordance with BS5446 within hall of house, exact position to be
determined with building inspector on site.
FIRE LEGEND
DRAINAGE.
Rain water pipes
Soil vent pipes
VENTILATION.
Mechanical extract fan ceiling mounted.
SVP
rwp
Heat Detector
VMZ Angle
Profile
38mm Timber
Batten
Breather
Membrane
Breather Membrane
38mm Timber Batten
VMZ Interlocking
Panels
VMZ Fixation Clip
Mesh
Welted Panels VMZinc with
perforated grids
VMZ Profile clip
Mesh
Mastic Sealant
Welted Panels VMZinc with
perforated grids
Soldered clip in VMZINC
BUILDING REGULATIONS
PROPOSED FLOOR PLANS
01202 280638
www.dotarchitecture.co.uk
as shown
MAY 14
PROPOSED GROUND FLOOR PLANSCALE 1:50@A1
23 Pearce AvenuePoole
BH14 8EG
102631BR
Mr & Mrs. S. Beales
PROPOSED FIRST FLOOR PLANSCALE 1:50@A1
G
All drawings to be read in conjunction withStructural Engineers drawings and calculations
Denotes existing structure
E Amended to clients comments AUG 14F Amended to clients comments SEP 14G Amended to clients comments SEP 14
PROPOSED ANGLE DETAILSCALE 1:10@A1
PROPOSED WINDOW DETAILSCALE 1:10@A1
_1m _3m _5m _10m0
rwp
WALL LEGEND
BLOCK AND BEAM'
'Periscopic' type vents to manufacturers details
30mm Finish Render
100mm Concrete Block
50mm Cavity
50mm Celotex
100mm Thermalite Turbo block ( to achieve K value of 0.11)
12.5mm plasterboard on 10mm dabs, taped and skimmed
STUD WORK
70mm Metal Studwork
25MM Wool batts internally (minimum thickness 25MM, Minimum
density 10 KG/M3)
15MM Plasterboard to both sides all joints to be taped and skimed.
Smoke detectorMains powered single station smoke detector units in strict
accordance with BS5446 within hall of house, exact position to be
determined with building inspector on site.
FIRE LEGEND
DRAINAGE.
Rain water pipes
Soil vent pipes
VENTILATION.
Mechanical extract fan ceiling mounted.
SVP
rwp
Heat Detector
W05 W06
W04
W06
D02D01
W01 W02
W03
SL01 SL01
W02
VMZ Continuous
welt piece
Aluminium Fascia
(to clients specification)
VMZ Fixation Clip
VMZINC Interlocking
Panels
38mm Timber Batten
screwed vertically
to Blockwork
75x75mm Batten screwed
onto vertical batten
White painted render
Existing wall make up
Render bead
Sika Sarnafil Sealant
15mm Ply
VMZINC
Interlocking
Panels
VMZ Continuous
welt piece
Aluminium Fascia
(to clients specification)
15mm Ply
38mm Timber Batten
screwed vertically
to Blockwork
Aluminium Trim
Timber Batten
Timber Joists to structural
engineers design
22mm ply sat on timber firings
Single Ply
Membrane
125mm Insulation on
top of rafters.
Insulation to be fixed
by Mechanical fixings
(U Value 0.16WmĮK)
Existing wall make up
BUILDING REGULATIONS
PROPOSED FLOOR PLANS
01202 280638
www.dotarchitecture.co.uk
as shown
MAY 14
23 Pearce AvenuePoole
BH14 8EG
103631BR
Mr & Mrs. S. BealesPROPOSED ROOF PLANSCALE 1:50@A1 PROPOSED EAVES DETAIL
SCALE 1:20@A3SCALE 1:10@A1
E
All drawings to be read in conjunction withStructural Engineers drawings and calculations
C Amended to clients comments AUG 14D Amended to clients comments AUG 14
PROPOSED FRONT ELEVATIONSCALE 1:200@A3SCALE 1:100@A1
PROPOSED SIDE ELEVATIONSCALE 1:200@A3SCALE 1:100@A1
E Amended to clients comments SEP 14
PROPOSED CLADDED RAIL DETAILSCALE 1:10@A1PROPOSED ROOF DETAIL TO GARAGE
SCALE 1:10@A1
_1m _3m _5m _10m0
White Render
D04
W07 W08W02
Marley EternitEquitone Pictura
Slate Effect RoofTile
W10
D05
W11
W09
WINDOWS SCHEDULE
ALL WINDOWS TO COMPLY WITHBUILDING REGULATIONS APPROVED DOCUMENT.
SAMPLE TO BE SUBMITTED BY CONTRACTOR FOR CLIENT APPROVALPRIOR TO ORDERING UNITS.
ALL WINDOWS TO HAVE TRICKLE VENTS AND DOUBLE GLAZED UNITS -
ALL WINDOW SIZES TO BE CONFIRMED ON SITE PRIOR TO ORDERS BEING PLACED
MANUFACTURER - TO BE CONFIRMED BY CONTRACTOR/CLIENTMAIN CONTRACTOR TO ALLOW PROVISIONAL SUM FOR THE SUPPLY ANDFITTING OF ALL WINDOW IRONMONGERY.
D01
SL01 SL01D02
W01
W02
W03
W04
W05
W051200mm x 560mm
W06
W061100mm x 560mm
W07
W07875mm x 1800mm
W08
W083044mm x 1800mm
D04 - Sliding6000mm x 2350mm
W09
D05
W08900mm x 1400mm
D04
W10
W11
W10940mm x 600mm
W11900mm x 1000mm
W07 W08W02
150.0
Breather Membrane
Aluminium Coping
VMZ Fixation Clip
38mm Timber Batten
screwed to Blockwork
200mm Ceiling Joists to
structural engineers design
100mm Dense Concrete Block
Lead Work on
top of
15mm Ply Sheathing
VMZINC Interlocking
Panels
ceiling material
to clients specification
VMZ Continuous
welt piece
Breather Membrane
Timber Fillet
75mm Celotex insulation(or equivilant)
10kg Densesound fibre
quilt
Plasterboard finish
BUILDING REGULATIONS
PROPOSED ELEVATIONS
01202 280638
www.dotarchitecture.co.uk
as shown
MAY 14
23 Pearce AvenuePoole
BH14 8EG
104631BR
Mr & Mrs. S. Beales
PROPOSED REAR ELEVATIONSCALE 1:200@A3SCALE 1:100@A1
PROPOSED SIDE ELEVATIONSCALE 1:100@A1
PROPOSED KEY SECTIONSCALE 1:50@A1
PROPOSED FOUNDATION DETAILSCALE 1:10@A1
PROPOSED FLAT ROOF DETAILSCALE 1:10@A1
F
PROPOSED INTERMEDIATE FLOOR DETAILSCALE 1:10@A1
E Amended to clients comments SEP 14F Amended to clients comments SEP 14